首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method is described for the qualiitative and quantitative determination of phenylbutazone and oxyphenbutazone in horse urine and plasma samples viewing antidoping control. A horse was administered intravenously with 3 g of phenylbutazone. For the qualitative determination, a screening by HPLC was performed after acidic extraction of the urine samples and the confirmation process was realized by GC-MS. Using the proposed method it was possible to detect phenylbutazone and oxyphenbutazone in urine for up to 48 and 120 h, respectively. For the quantitation of these drugs the plasma was deproteinized with acetonitrile and 20 gml were injected directly into the HPLC system equipped with a UV detector and LiChrospher RP-18 column. The mobile phase used was 0.01 M acetic acid in methanol (45:55, v/v). The limit of detection was 0.5 μg/ml for phenylbutazone and oxyphenbutazone and the limit of quantitation was 1.0 μg/ml for both drugs. Using the proposed method it was possible to quantify phenylbutazone up to 30 h and oxyphenbutazone up to 39 h after administration.  相似文献   

2.
An HPLC method has been developed for the separation and the determination of caffeine and its metabolites in urine samples using a one extraction–analysis run and UV detection. The compounds were extracted by liquid–liquid extraction using chloroform–isopropylalcohol (85:15, v/v). Chromatographic separation was accomplished on an ODS analytical column with a mobile phase containing 0.05% acetic acid/methylalcohol (92.5:7.5, v/v). Compounds were monitored at 280 nm. The method was validated for the determination of AFMU, 1X, 1U, 17X and 17U caffeine metabolites required to assess the metabolic activity of the enzymes subject to in vivo caffeine testing. The validated assay was applied to urine samples from ten healthy volunteers. The method was proved to be suitable to assess simultaneously the enzymatic activity of cytochrome P450 CYP1A2 and CYP2A6, as well as N-acetyltransferase and xanthine oxidase.  相似文献   

3.
A simple high-performance liquid chromatographic (HPLC) method has been developed for the determination of epimedin C in rat plasma and applied to a pharmacokinetic study in rats after administration of Herba Epimedii extract. After addition of carbamazepine as an internal standard plasma samples were extracted with ethyl acetate. HPLC analysis of the extracts was performed on a Hypersil ODS2 analytical column using acetonitrile -0.4% acetic acid (25:75, v/v) as the mobile phase. The UV detector was set at 260 nm. The standard curve was linear over the range 0.05-4.0 microg/mL. The lower limit of quantification was 0.05 microg/mL. The HPLC method developed could be easily applied to the determination and pharmacokinetic study of epimedin C in rat plasma after giving the animals Herba Epimedii extract.  相似文献   

4.
The development and validation of a high-performance liquid chromatographic (HPLC) assay for determination of busulfan concentrations in human plasma for pharmacokinetic studies is described. Plasma samples containing busulfan and 1,6-bis(methanesulfonyloxy)hexane, and internal standard, were prepared by derivatization with sodium diethyldithio-carbamate (DDTC) followed by addition of methanol and extraction with ethyl acetate. The extract was dried under nitrogen and the samples reconstituted with 100 μl of methanol prior to HPLC determination. Chromatography was accomplished using a Waters NovaPak octadecylsilyl (ODS) (150×3.9 mm I.D.) analytical column, NovaPak ODS guard column, and mobile phase of methanol-water (80:20, v/v) at a flow-rate of 0.8 ml/min with UV detection at 251 nm. The limit of detection was 0.0200 μg/ml (signal-to-noise ratio of 6) with a limit of quantitation (LOQ) of 0.0600 μg/ml for busulfan in plasma. Calibration curves were linear from 0.0600 to 3.00 μg/ml in plasma (500 μl) using a weighting scheme. Precision of the assay, as represented by C.V. of the observed peak area ration values, ranged from 4.41 to 13.5% (13.5% at LOQ). No day-to-day variability was observed in predicted concentration values and the bias was low for all concentrations evaluated (bias: 0 to 4.76%; LOQ: 2.91%). The mean derivatization and extraction yield observed for busulfan in plasma at 0.200, 1.20 and 2.00 μg/ml was 98.5% (range 93.4 to 107%). Plasma samples containing potential busulfan metabolites and co-administered drugs, which may be present in clinical samples, provided no response indicating this assay procedure is selective for busulfan. This method was used to analyze plasma concentrations following administration of a 1 mg/kg oral busulfan dose.  相似文献   

5.
A sensitive and simple HPLC method was developed for the determination of a novel compound, a potential anti-cancer drug, N-(2-hydroxy-5-nitrophenylcarbamothioyl)-3,5-dimethylbenzamide (DM-PIT-1), a member of the new structural class of non-phosphoinositide small molecule antagonist of phosphatidylinositol-3,4,5-trisphosphate-pleckstrin-homology domain interactions, in mouse plasma and tumor tissue homogenates. The chromatographic separation of DM-PIT-1 was achieved on C18 column using isocratic elution with acetonitrile-water (70:30) containing 0.1% formic acid (v/v). DM-PIT-1 was detected by UV absorbance at 320 nm and confirmed by LC-MS. The extraction of the DM-PIT-1 from the plasma and tumor tissue with methylene chloride resulted in its high recovery (70-80%). HPLC calibration curves for DM-PIT-1 based on the extracts from the mouse plasma and tumor tissue samples were linear over a broad concentration range of 0.25-20 μg/ml/g, with intra/inter-day accuracy of 95% and the precision of variation below 10%. The limits of detection and quantification were 0.1 ng and 0.2 ng, respectively. The described method was successfully applied to study the pharmacokinetics of the DM-PIT-1 following the parenteral injections of DM-PIT-1 entrapped in 1,2-disteratoyl-sn-glycero-3-phosphoethanolamine-N-[methoxy(polyethylene-glycol)-2000] (PEG-PE) micelles.  相似文献   

6.
The development and validation of a high-performance liquid chromatographic and UV detection method was accomplished for quantitative determination of levamisole in chicken tissues, eggs and plasma. The chromatographic separation was achieved on Luna 5 microm C(18) column using a mobile phase of 0.2% acetic acid in water:methanol (50:50 (v/v)) and Pic B-7 low UV reagent and the pH was adjusted to 7.31 with ammonium hydroxide and UV wavelength was 225 nm. Limits of quantification were 0.025 microg/g for all tissues and 0.003 microg/ml for plasma. Limit of detection was 0.001 microg/g for tissues and plasma.  相似文献   

7.
不同品种菊花和贵州产野菊花中木犀草素的含量比较   总被引:1,自引:0,他引:1  
目的测定并比较不同品种菊花和贵州产野菊花中木犀草素的含量。方法用高效液相色谱法测定木犀草素的含量。色谱柱为ODS柱(4.6mm×250mm,5μm),流动相为甲醇-水-冰醋酸(体积比45:55:0.4),检测波长为254nm,流速1.0mL/min。结果7个菊花样品的木犀草素含量,以贵州野菊花的木犀草素含量最高(3.876mg/g),杭菊的木犀草素含量最低(0.302mg/g)。结论贵州产野菊花中木犀草素的含量均高于其他品种菊花,具有较高的药用价值。  相似文献   

8.
A high-performance liquid chromatography (HPLC) method was developed and validated for the determination of orientin in rabbit plasma using ultraviolet (UV) absorbance detection. Orientin is the active constituent of purified herbal extract (TRO PE) from the flower of Trollius chinensis Bunge. Protein precipitation was used as the sample preparation technique. A Diamonsil C18 column (150 mmx4.6 mm, 5 microm) was equilibrated with a mobile phase composed of 0.1% acetic acid/methanol/acetonitrile (80/5/15, v/v/v). The calibration curve of orientin in rabbit plasma was linear in the concentration range of 0.530-53.0 microg/mL. This validated method was successfully applied to a pharmacokinetic study in rabbits after the intravenous administrations of orientin and TRO PE at three different doses.  相似文献   

9.
A high-performance liquid chromatographic method for quantitation of ibuprofen from serum and application of this method to ibuprofen disposition in the dog is described. The drug was extracted from acidified plasma with dichloromethane. The internal standard used was a methanolic solution of 4-n-butylphenylacetic acid. A μBondapak C1 column was used for analysis; the mobile phase was methanol—water—glacial acetic acid (pH 3.4) (75:24:1, v/v). A wavelength of 272 nm was used to monitor ibuprofen and the internal standard.Method sensitivity was 0.5 μg/ml serum using either 0.5 or 1.0 ml of sample, and no interference was found from endogenous compounds or other commonly used anti-inflammatory agents. The coefficients of variation of the method were 4.2% and 6.0% for samples containing 50.0 and 6.25 μg/ml of ibuprofen, respectively, and the calibration curve was linear for the range of 0.5 to 100 μg/ml. This method was demonstrated to be suitable for pharmacokinetic and/or biopharmaceutical studies of ibuprofen in man and the dog.  相似文献   

10.
The residues of sulfonamides (SAs) in the foods of animal origin are of the major concern because they are harmful to the consumer's health and could induce pathogens to develop resistance. Rapid and efficient determination methods are urgently in need. A quantitative high performance liquid chromatography method (HPLC) and a confirmative liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 18 sulfonamides such as sulfamidinum, sulfanilamide, sulfisomidine, sulfadiazine, sulfapyridine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethoxypyridazine, sulfamethoxydiazine, sulfisoxazole, sulfachloropyridazine, sulfamethoxazole, sulfamonomethoxine, sulfadoxine, sulfaclozine, sulfadimethoxine, sulfaquinoxaline in the muscles, livers and kidneys of swine, bovine and chicken were developed and validated. The sample preparation procedures included a pressurized liquid extraction (PLE) with acetonitrile conducted at elevated temperature (70°C) and pressure (1400 psi). After clean-up with hydrophilic-lipophilic balance cartridge, the extraction solution was concentrated and analyzed by HPLC and LC-MS/MS analysis. 18 SAs were separated by the HPLC with a Zorbax SB-Aq-C18 column and the mobile phase of methanol/acetonitrile/1% acetic acid with a gradient system. The wavelength of UV for the HPLC detection was set at 285 nm. The LC-MS/MS analysis was achieved with a Hypersil Golden column and the mobile phase of acetonitrile and 0.1% formic acid aqueous solution with two gradient systems. The Limits of detection (LOD) and the limits of quantitation (LOQ) were 3 μg/kg and 10 μg/kg, respectively, for both of the HPLC and LC-MS/MS. Linearity was obtained with an average coefficient of determination (R) higher than 0.9980 over a dynamic range from the LOQ value up to 5000 μg/kg. The recoveries of the methods range from 71.1% to 118.3% with the relative standard derivation less than 13%. The peaks of interest with no interferences were observed throughout the chromatographic run. The sample pretreatment provided efficient extraction and cleanup that enables a sensitive and rugged determination of 18 SAs, the obtained results revealed that PLE, in comparison with other sample preparation methods applied, has significantly higher efficacy for SAs isolation from animal tissues.  相似文献   

11.
In order to facilitate the quality control of Traditional Chinese Medicine (TCM) products containing both Gegen (Pueraria lobata) and Danshen (Salvia miltiorrhiza), a new and simple HPLC method for the simultaneous determination of 10 active components in these products has been developed. The chromatographic separation was carried out on a C(18) column eluted with a mobile phase consisting of 0.1% acetic acid in water and 0.1% acetic acid in acetonitrile with gradient elution. The eluent was monitored by a photodiode array UV detector at a wavelength of 250 nm for Gegen components including puerarin, daidzein 8-C-apiosyl-glucoside, daidzin and daidzein, and at 270 nm for Danshen components including danshensu, protocatechuic aldehyde, salvianolic acid B, cryptotanshinone, tanshinone I and tanshinone IIa. Excellent chromatographic separation was achieved for all studied compounds with good linearity (r(2)> 0.999) over the studied concentration ranges. The developed method has been applied to the simultaneous determination of the 10 studied compounds in commercially available products containing both Gegen and Danshen. The TCM product samples were extracted by sonication with a mixture of methanol:water (80:20) containing 0.5% acetic acid. Extraction recoveries for all studied compounds were in the range of 96.01-106.18%. The intra-day and inter-day variations were less than 7.25 and 5.44%, respectively, for all studied compounds. The developed method has not only proved to be effective in the simultaneous determination of the 10 components, but also provides a convenient quality control approach for TCM products containing both Gegen and Danshen.  相似文献   

12.
通过薄层色谱(TLC)与高效液相色谱(HPLC)联用技术鉴定了暗纹东方鲀(Takifugu obscurus)肌肉中存在肌肽和谷胱甘肽,同时利用高效液相色谱法测定了肌肽和谷胱甘肽(GSH)的含量。薄层层析采用的展开剂为正丁醇:乙酸:水(4∶2∶1),层析板为硅胶板。高效液相色谱利用Kromasil C18反相柱分析,流动相为10%的纯乙腈和90%含有0.05%三氟乙酸的超纯水。结果表明:通过薄层色谱和高效液相色谱鉴定了暗纹东方鲀肌肉中肌肽和谷胱甘肽,其中暗纹东方鲀肌肉中肌肽含量约213μg/g(鲜重),还原性谷胱甘肽含量约211μg/g(鲜重)。本法样品无需衍生,操作简便,适合于暗纹东方鲀肌肉中肌肽和谷胱甘肽的测定。本文为生物体内肌肽和谷胱甘肽的研究提供借鉴意义。  相似文献   

13.
A simple and sensitive high-performance liquid chromatography (HPLC) method utilizing UV detection was developed for the determination of plasma pyrrole (Py)-imidazole (Im) polyamides in rats and applied to the pharmacokinetic study of compounds. After deproteinization of plasma with methanol, Py-Im polyamides were analyzed with a reversed-phase TSK-GEL ODS-80TM (4.6 mmx15.0 cm TOSOH Co., Japan) column maintained at 40 degrees C. The mobile phase solvent A was 0.1% acetic acid and the solvent B was HPLC-grade acetonitrile (0-10 min, A: 100-20%, B: 0-80% linear gradient; 10-15 min, A: 40%, B: 60%). The flow rate was 1.0 ml/min. The detection wavelength was set at 310 nm. The method was used to determine the plasma concentration time profiles of Py-Im polyamides after intravenous injection.  相似文献   

14.
A rapid and simple high-performance liquid chromatographic (HPLC) method has been developed and validated for determination of scopoletin in rat plasma using psoralen as internal standard. Chromatographic separation was achieved on a C(18) column using methanol and distilled water (49:51, v/v) containing 0.05% (v/v) phosphoric acid as mobile phase. The UV detector was set at 345 nm. The calibration curve was linear over the range of 0.165-9.90 microg/ml with a correlation coefficient of 0.9994. The recovery for plasma samples of 0.165, 1.32 and 6.60 microg/ml was 93.2%, 95.9% and 95.5%, respectively. The RSD of intra- and inter-day assay variations was less than 6.7%. This HPLC assay is a precise and reliable method for the analysis of scopoletin in pharmacokinetic studies.  相似文献   

15.
建立高效液相色谱法测定鸢尾苷元磺酸钠(4′,5,7-三羟基-6-甲氧基异黄酮-5′-磺酸钠)及其制剂泰克吉宁注射液的含量及有关物质。采用C18色谱柱(150×4.6mm,5μm),流动相为甲醇-5%醋酸水(80:20),流速为1.0mL/min,检测波长为263nm。鸢尾苷元磺酸钠在11~100μg/mL范围内线性关系良好,回归方程Y=43.3609X-1.5973(r=0.99998),平均回收率为99.77%(n=9)。最低检测限为0.052μg/mL,与有关物质分离良好。本法快速、简便、准确,专属性强。  相似文献   

16.
目的:利用高效液相色谱(HPLC)法测定重组人干扰素α-2b注射液中EDTA二钠(乙二胺四乙酸二钠)的含量。方法:将EDTA二钠与氯化铁溶液于70℃水浴中反应20 min左右;色谱柱为SunFire C18(250 mm×4.6 mm,5μm,Waters),流动相为5%甲醇+95%0.64 g/L四丁基溴化铵和4.1 g/L三水合乙酸钠混合液,用冰乙酸调pH值至4.0,流速1 mL/min,检测波长254 nm。结果:该测定方法线性范围为0.025~0.5 g/L,线性关系良好(r=0.9997),加样回收率为98.27%(n=9,RSD=2.55%)。结论:本方法准确、快速、可靠,可用于重组人干扰素α-2b注射液中EDTA二钠含量的测定。  相似文献   

17.
An improved, more efficient method for the determination of metoprolol and its two metabolites in human urine is reported. The simultaneous analysis of the zwitterionic metoprolol acidic metabolite (III, H117/04) with the basic metabolites α-hydroxymetoprolol (II, H119/66), metoprolol (I) and guanoxan (IV, internal standard) was achieved employing solid-phase extraction and isocratic reversed-phase HPLC. The analytes were extracted from urine (100 μl) using C18 solid-phase extraction cartridges (100 mg), and eluted with aqueous acetic acid (0.1%, v/v)–methanol mixture (40:60, v/v, 1.2 ml). The eluents were concentrated (250 μl) under vacuum, and aliquots (100 μl) were analysed by HPLC with fluorescence detection at 229 nm (excitation) and 309 nm (emission) using simple isocratic reversed-phase HPLC (Novapak C18 radial compression cartridge, 4 μm, 100×5 mm I.D.). Acetonitrile–methanol–TEA/phosphate buffer pH 3.0 (9:1:90, v/v) was employed as the eluent (1.4 ml/min). All components were fully resolved within 18 min, and the calibration curves for the individual analytes were linear (r2≥0.996) within the concentration range of 0.25–40.0 mg/ml. Recoveries for all four analytes were greater than 76% (n=4). The assay method was validated with intra-day and inter-day variations less than 2.5%.  相似文献   

18.
A reliable high-performance liquid chromatographic method has been validated for determination of gallamine in rat plasma, muscle tissue and microdialysate samples. A C18 reversed-phase column with mobile phase of methanol and water containing 12.5 mM tetrabutyl ammonium (TBA) hydrogen sulphate (22:78, v/v) was used. The flow-rate was 1 ml/min with UV detection at 229 nm. Sample preparation involved protein precipitation with acetonitrile for plasma and muscle tissue homogenate samples. Microdialysate samples were injected into the HPLC system without any sample preparation. Intra-day and inter-day accuracy and precision of the assay were <13%. The limit of quantification was 1 μg/ml for plasma, 1.6 μg/g for muscle tissue and 0.5 μg/ml for microdialysate samples. The assay was applied successfully to analysis of samples obtained from a pharmacokinetic study in rats using the microdialysis technique.  相似文献   

19.
High performance liquid chromatographic (HPLC) methods were validated for the determination of aripiprazole (OPC-14597, Abilify) in rat plasma and brain. Separation was by Nova-pak phenyl column; flow rate, 1.0 ml/min; mobile phase, acetonitrile-methanol-20 mM sodium sulfate-acetic acid (27:25:48:1, v/v/v/v); UV detection at 254 nm. Reproducibility in plasma and brain showed excellent precision (within 7.8 and 10.6%) and accuracy (96.0-102.4% and 99.0-108.7%) with calibration curve ranges 10.0-2000 ng/ml and 30.0-6000 ng/g, respectively. Validated HPLC methods were successfully applied to pharmacokinetic study of aripiprazole in rats, demonstrating brain concentrations after oral administration five times higher than plasma concentrations.  相似文献   

20.
A modification of existing HPLC assay methods is described for the measurement of dapsone and monoacetyldapsone in 50-μl samples of plasma and whole blood. This method, in particular the use of small sample volumes dried onto filter paper strips, is applicable to multi-sample clinical and pharmacokinetic studies in children with malaria, who are often anaemic, and where sample volume must be kept to a minimum. Basified samples were extracted into 5 ml of ethyl acetate-tert.-butylmethyl ether (1:1, v/v), chromatographed on a μBondapaK C18, 10 μm column with water-acetonitrile-glacial acetic acid (81:17.5:5, v/v) containing 2 g/l 1-octanesulphonic acid as the mobile phase and detected at 274 nm.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号