首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The voltage-dependent activity of prestin, the outer hair cell (OHC) motor protein essential for its electromotility, enhances the mammalian inner ear's auditory sensitivity. We investigated the effect of prestin's activity on the plasma membrane's (PM) susceptibility to electroporation (EP) via cell-attached patch-clamping. Guinea pig OHCs, TSA201 cells, and prestin-transfected TSA cells were subjected to incremental 50 mus and/or 50 ms voltage pulse trains, or ramps, at rates from 10 V/s to 1 kV/s, to a maximum transmembrane potential of +/-1000 mV. EP was determined by an increase in capacitance to whole-cell levels. OHCs were probed at the prestin-rich lateral PM or prestin-devoid basal portion; TSA cells were patched at random points. OHCs were consistently electroporated with 50 ms pulses, with significant resistance to depolarizing pulses. Although EP rarely occurred with 50 mus pulses, prior stimulation with this protocol had a significant effect on the sensitivity to EP with 50 ms pulses, regardless of polarity or PM domain. Consistent with these results, resistance to EP with depolarizing 10-V/s ramps was also found. Our findings with TSA cells were comparable, showing resistance to EP with both depolarizing 50-ms pulses and 10 V/s ramps. We conclude prestin significantly affects susceptibility to EP, possibly via known biophysical influences on specific membrane capacitance and/or membrane stiffness.  相似文献   

2.
An increased permeability of a cell membrane during the application of high-voltage pulses results in increased transmembrane transport of molecules that otherwise cannot enter the cell. Increased permeability of a cell membrane is accompanied by increased membrane conductivity; thus, by measuring electric conductivity the extent of permeabilized tissue could be monitored in real time. In this article the effect of cell electroporation caused by high-voltage pulses on the conductivity of a cell suspension was studied by current-voltage measurements during and impedance measurement before and after the pulse application. At the same time the percentage of permeabilized and survived cells was determined and the extent of osmotic swelling measured. For a train of eight pulses a transient increase in conductivity of a cell suspension was obtained above permeabilization threshold in low- and high-conductive medium with complete relaxation in <1 s. Total conductivity changes and impedance measurements showed substantial changes in conductivity due to the ion efflux in low-conductive medium and colloid-osmotic swelling in both media. Our results show that by measuring electric conductivity during the pulses we can detect limit permeabilization threshold but not directly permeabilization level, whereas impedance measurements in seconds after the pulse application are not suitable.  相似文献   

3.
Conventional electroporation (EP) by 0.1 to 1 kV/cm pulses longer than 100 micros, and supra-electroporation by 10 to 300 kV/cm pulses shorter than 1 micros cause different cellular effects. Conventional EP delivers DNA, proteins, small drugs, and fluorescent indicators across the plasma membrane (PM) and causes moderate levels of phosphatidylserine (PS) translocation at the PM. We hypothesize that supra-EP is central to intracellular effects such as apoptosis induction and higher levels of PS translocation. Our cell system model has 20,000 interconnected local models for small areas of the PM and organelle membranes, small regions of aqueous media, appropriate resting potentials, and the asymptotic EP model. Conventional EP primarily affects the PM, but with a hint of endoplasmic reticulum involvement. Supra-EP can involve all of a cell's membrane at the largest fields. Conventional EP fields tend to go around cells, but supra-EP fields go through cells, extensively penetrating organelles.  相似文献   

4.
In this study adherent animal cells were grown to confluence on circular gold-film electrodes of 250 μm diameter that had been deposited on the surface of a regular culture dish. The impedance of the cell-covered electrode was measured at designated frequencies to monitor the behavior of the cells with time. This approach is referred to as electric cell-substrate impedance sensing or short ECIS in the literature. The gold-film electrodes were also used to deliver well-defined AC voltage pulses of several volts amplitude and several hundred milliseconds duration to the adherent cells in order to achieve reversible membrane electroporation (in situ electroporation=ISE). Electroporation-assisted introduction of membrane impermeable molecules into the cytoplasm was studied by using FITC-labeled dextran molecules of different molecular weights. Probes as big as 2MDa were successfully loaded into the cells residing on the electrode surface. Time-resolved impedance measurements before and immediately after the electroporation pulse revealed the kinetics of membrane resealing as well as subsequent changes in cell morphology. Cells recovered from the electroporation pulse within less than 90 min. When membrane-impermeable, bioactive compounds like N(3)(-) or bleomycin were introduced into the cells by in situ electroporation, concomitant ECIS readings sensitively reported on the associated response of the cells to these toxins as a function of time (ISE-ECIS).  相似文献   

5.
We have developed a gene transfection method called water-in-oil droplet electroporation (EP) that uses a dielectric oil and a liquid droplet containing live cells and exogenous DNA. When a cell suspension droplet is placed between a pair of electrodes, an intense DC electric field can induce droplet deformation, resulting in an instantaneous short circuit caused by the droplet elongating and contacting the two electrodes simultaneously. Small transient pores are generated in the cell membrane during the short, allowing the introduction of exogenous DNA into the cells. The droplet EP was characterized by varying the following experimental parameters: applied voltage, number of short circuits, type of medium (electric conductivity), concentration of exogenous DNA, and size of the droplet. In addition, the formation of transient pores in the cell membrane during droplet EP and the transfection efficiency were evaluated.  相似文献   

6.

Background

Nanosecond electric pulses (EP) disrupt cell membrane and organelles and cause cell death in a manner different from the conventional irreversible electroporation. We explored the cytotoxic effect of 10-ns EP (quantitation, mechanisms, efficiency, and specificity) in comparison with 300-ns, 1.8- and 9-μs EP.

Methods

Effects in Jurkat and U937 cells were characterized by survival assays, DNA electrophoresis and flow cytometry.

Results

10-ns EP caused apoptotic or necrotic death within 2–20 h. Survival (S, %) followed the absorbed dose (D, J/g) as: S = αD(−K), where coefficients K and α determined the slope and the “shoulder” of the survival curve. K was similar in all groups, whereas α was cell type- and pulse duration-dependent. Long pulses caused immediate propidium uptake and phosphatidylserine (PS) externalization, whereas 10-ns pulses caused PS externalization only.

Conclusions

1.8- and 9-μs EP cause cell death efficiently and indiscriminately (LD50 1–3 J/g in both cell lines); 10-ns EP are less efficient, but very selective (LD50 50–80 J/g for Jurkat and 400–500 J/g for U937); 300-ns EP show intermediate effects. Shorter EP open propidium-impermeable, small membrane pores (”nanopores”), triggering different cell death mechanisms.

General significance

Nanosecond EP can selectively target certain cells in medical applications like tumor ablation.  相似文献   

7.
Electroporation-induced electrosensitization   总被引:2,自引:0,他引:2  

Background

Electroporation is a method of disrupting the integrity of cell membrane by electric pulses (EPs). Electrical modeling is widely employed to explain and study electroporation, but even most advanced models show limited predictive power. No studies have accounted for the biological consequences of electroporation as a factor that alters the cell''s susceptibility to forthcoming EPs.

Methodology/Principal Findings

We focused first on the role of EP rate for membrane permeabilization and lethal effects in mammalian cells. The rate was varied from 0.001 to 2,000 Hz while keeping other parameters constant (2 to 3,750 pulses of 60-ns to 9-µs duration, 1.8 to 13.3 kV/cm). The efficiency of all EP treatments was minimal at high rates and started to increase gradually when the rate decreased below a certain value. Although this value ranged widely (0.1–500 Hz), it always corresponded to the overall treatment duration near 10 s. We further found that longer exposures were more efficient irrespective of the EP rate, and that splitting a high-rate EP train in two fractions with 1–5 min delay enhanced the effects severalfold.

Conclusions/Significance

For varied experimental conditions, EPs triggered a delayed and gradual sensitization to EPs. When a portion of a multi-pulse exposure was delivered to already sensitized cells, the overall effect markedly increased. Because of the sensitization, the lethality in EP-treated cells could be increased from 0 to 90% simply by increasing the exposure duration, or the exposure dose could be reduced twofold without reducing the effect. Many applications of electroporation can benefit from accounting for sensitization, by organizing the exposure either to maximize sensitization (e.g., for sterilization) or, for other applications, to completely or partially avoid it. In particular, harmful side effects of electroporation-based therapies (electrochemotherapy, gene therapies, tumor ablation) include convulsions, pain, heart fibrillation, and thermal damage. Sensitization can potentially be employed to reduce these side effects while preserving or increasing therapeutic efficiency.  相似文献   

8.
The permeabilization of biological membranes by electric fields, known as electroporation, has been traditionally performed with square electric pulses. These signals distribute the energy applied to cells in a wide frequency band. This paper investigates the use of sine waves, which are narrow band signals, to provoke electropermeabilization and the frequency dependence of this phenomenon.Single bursts of sine waves at different frequencies in the range from 8 kHz–130 kHz were applied to cells in vitro. Electroporation was studied in the plasma membrane and the internal organelles membrane using calcium as a permeabilization marker. Additionally, a double-shell electrical model was simulated to give a theoretical framework to our results.The electroporation efficiency shows a low pass filter frequency dependence for both the plasma membrane and the internal organelles membrane. The mismatch between the theoretical response and the observed behavior for the internal organelles membrane is explained by a two-step permeabilization process: first the permeabilization of the external membrane and afterwards that of the internal membranes. The simulations in the model confirm this two-step hypothesis when a variable plasma membrane conductivity is considered in the analysis.This study demonstrates how the use of narrow-band signals as sine waves is a suitable method to perform electroporation in a controlled manner. We suggest that the use of this type of signals could bring a simplification in the investigations of the very complex phenomenon of electroporation, thus representing an interesting option in future fundamental studies.  相似文献   

9.
Electroporation is a fascinating cell membrane phenomenon with several existing biological applications and others likely. Although DNA introduction is the most common use, electroporation of isolated cells has also been used for (1) introduction of enzymes, antibodies, and other biochemical reagents for intracellular assays; (2) selective biochemical loading of one size cell in the presence of many smaller cells; (3) introduction of virus and other particles; (4) cell killing under nontoxic conditions; and (5) insertion of membrane macromolecules into the cell membrane. More recently, tissue electroporation has begun to be explored, with potential applications including (1) enhanced cancer tumor chemotherapy, (2) gene therapy, (3) transdermal drug delivery, and (4) noninvasive sampling for biochemical measurement. As presently understood, electroporation is an essentially universal membrane phenomenon that occurs in cell and artificial planar bilayer membranes. For short pulses (μs to ms), electroporation occurs if the transmembrane voltage, U(t), reaches 0.5–1.5 V. In the case of isolated cells, the pulse magnitude is 103–104 V/cm. These pulses cause reversible electrical breakdown (REB), accompanied by a tremendous increase molecular transport across the membrane. REB results in a rapid membrane discharge, with the elevated U(t) returning to low values within a few microseconds of the pulse. However, membrane recovery can be orders of magnitude slower. An associated cell stress commonly occurs, probably because of chemical influxes and effluxes leading to chemical imbalances, which also contribute to eventual survival or death. Basic phenomena, present understanding of mechanism, and the existing and potential applications are briefly reviewed.  相似文献   

10.
Cell permeabilization by electric pulses (EP), or electroporation, is widely used for intracellular delivery of drugs and plasmids, as well as for tumour and tissue ablation. We found that cells pre‐treated with 100‐μs EP develop delayed hypersensitivity to subsequent EP applications. Sensitizing B16 and CHO cells by splitting a single train of eight 100‐μs EP into two trains of four EP each (with 5‐min. interval) decreased the LD50 1.5–2 times. Sensitization profoundly enhanced the electroporation‐assisted uptake of bleomycin, a cell‐impermeable cytotoxic agent accepted for killing tumours by electrochemotherapy. EP exposures that were not lethal per se caused cell death in the presence of bleomycin and proportionally to its concentration. Sensitizing cells by a split‐dose EP exposure increased bleomycin‐mediated lethality to the same extent as a 10‐fold increase in bleomycin concentration when using a single EP dose. Likewise, sensitization by a split‐dose EP exposure (without changing the overall dose, pulse number, or amplitude) enhanced the electroporative uptake of propidium up to fivefold. Enhancement of the electroporative uptake appears a key mechanism of electrosensitization and may benefit electrochemotherapy and numerous applications that employ EP for cell permeabilization.  相似文献   

11.
Diverse effects of nanosecond pulsed electric fields on cells and tissues   总被引:11,自引:0,他引:11  
The application of pulsed electric fields to cells is extended to include nonthermal pulses with shorter durations (10-300 ns), higher electric fields (< or =350 kV/cm), higher power (gigawatts), and distinct effects (nsPEF) compared to classical electroporation. Here we define effects and explore potential application for nsPEF in biology and medicine. As the pulse duration is decreased below the plasma membrane charging time constant, plasma membrane effects decrease and intracellular effects predominate. NsPEFs induced apoptosis and caspase activation that was calcium-dependent (Jurkat cells) and calcium-independent (HL-60 and Jurkat cells). In mouse B10-2 fibrosarcoma tumors, nsPEFs induced caspase activation and DNA fragmentation ex vivo, and reduced tumor size in vivo. With conditions below thresholds for classical electroporation and apoptosis, nsPEF induced calcium release from intracellular stores and subsequent calcium influx through store-operated channels in the plasma membrane that mimicked purinergic receptor-mediated calcium mobilization. When nsPEF were applied after classical electroporation pulses, GFP reporter gene expression was enhanced above that observed for classical electroporation. These findings indicate that nsPEF extend classical electroporation to include events that primarily affect intracellular structures and functions. Potential applications for nsPEF include inducing apoptosis in cells and tumors, probing signal transduction mechanisms that determine cell fate, and enhancing gene expression.  相似文献   

12.
Clinical electroporation (EP) is a rapidly advancing treatment modality that uses electric pulses to introduce drugs or genes into, e.g., cancer cells. The indication of successful EP is an instant plasma membrane permeabilization in the treated tissue. A noninvasive means of monitoring such a tissue reaction represents a great clinical benefit since, in case of target miss, retreatment can be performed immediately. We propose diffusion-weighted magnetic resonance imaging (DW-MRI) as a method to monitor EP tissue, using the concept of the apparent diffusion coefficient (ADC). We hypothesize that the plasma membrane permeabilization induced by EP changes the ADC, suggesting that DW-MRI constitutes a noninvasive and quick means of EP verification. In this study we performed in vivo EP in rat brains, followed by DW-MRI using a clinical MRI scanner. We found a pulse amplitude–dependent increase in the ADC following EP, indicating that (1) DW-MRI is sensitive to the EP-induced changes and (2) the observed changes in ADC are indeed due to the applied electric field.  相似文献   

13.
Entamoeba histolytica, and invasive enteric protozoa, kills mammalian target cells by sequential adherence and cytolytic events. Using platinum plate electrodes with an alternating current source placed in a Wheatstone bridge circuit, the impedance (resistance to ion flow) of a cell suspension of axenic amebae (strain HM1-IMSS) was measured. The impedance of the amebic cell suspension, expressed as resistivity (in ohm-cm), was significantly greater than the test solution and increased with decreasing temperature or greater cell packing (P less than 0.01), indicating that the resistivity measurements reflected the impedance of the amebic surface membrane. Cytochalasin D (10 micrograms/ml), a microfilament inhibitor which inhibited amebic in vitro adherence and cytolysis of target Chinese hamster ovary (CHO) cells (P less than 0.001), also increased resistivity of the amebic suspension (P less than 0.01). Exposure of amebae to bepridil (10(5) M), a slow-channel blocker, inhibited amebic killing of target cells (P less than 0.01) and also increased the resistivity of the amebic suspension (P less than 0.01), but both to a lesser degree than cytochalasin D (P less than 0.001). In contrast, exposure of amebae to verapamil followed by washing had no effect on amebic killing of target cells or resistivity of the amebic suspension. The increased resistivity measured in cytochalasin D or following exposure to bepridil was not due to a change in cell density of the amebic suspension. These studies indicate that changes in impedance of the amebic surface membrane are produced by bepridil and cytochalasin D. The effect of these agents on membrane impedance may contribute directly to the concurrent observed alteration in amebic cytopathogenic capacity or may serve as a parallel marker for the cell membrane alterations induced by such pharmacologic agents which inhibit amebic microfilament function or calcium flux.  相似文献   

14.
Electropermeabilization/electroporation (EP) is a physical method that by application of electric pulses to cells increases cell membrane permeability and enables the introduction of molecules into the cells. One of the uses of EP in vivo is plasmid DNA electrotransfer to the skin for DNA vaccination. EP of tissues induces reduction of blood flow and, in combination with plasmid DNA, induction of an immune response. One of the EP protocols for plasmid DNA electrotransfer to the skin is a combination of high-voltage (HV) and low-voltage (LV) pulses. However, the effects of this pulse combination on skin-vessel blood flow are not known. Therefore, using intravital microscopy in a dorsal window chamber in mice and fluorescently labeled dextrans, the effects of one HV and eight LV pulses on skin vasculature were investigated. In addition, a detailed histological analysis was performed. Image analysis of fluorescence intensity changes demonstrated that EP induces a transient constriction and increased permeability of blood vessels as well as a “vascular lock.” Histological analysis revealed rounding up of endothelial cells and stacking up of erythrocytes at 1?h after EP. In addition, extravasation of erythrocytes and leukocyte infiltration accompanied by edema were determined up to 24?h after EP. In conclusion, our results show that blood flow modifying effects of EP in skin contribute to the infiltration of immune cells in the exposed area. When combined with plasmid DNA for vaccination, this could enable the initial and prolonged contact of immune cells with encoded therapeutic proteins.  相似文献   

15.
The effects of intense submicrosecond electrical pulses on cells   总被引:5,自引:0,他引:5       下载免费PDF全文
A simple electrical model for living cells predicts an increasing probability for electric field interactions with intracellular substructures of both prokaryotic and eukaryotic cells when the electric pulse duration is reduced into the sub-microsecond range. The validity of this hypothesis was verified experimentally by applying electrical pulses (durations 100 micros-60 ns, electric field intensities 3-150 kV/cm) to Jurkat cells suspended in physiologic buffer containing propidium iodide. Effects on Jurkat cells were assessed by means of temporally resolved fluorescence and light microscopy. For the longest applied pulses, immediate uptake of propidium iodide occurred consistent with electroporation as the cause of increased surface membrane permeability. For nanosecond pulses, more delayed propidium iodide uptake occurred with significantly later uptake of propidium iodide occurring after 60 ns pulses compared to 300 ns pulses. Cellular swelling occurred rapidly following 300 ns pulses, but was minimal following 60 ns pulses. These data indicate that submicrosecond pulses achieve temporally distinct effects on living cells compared to microsecond pulses. The longer pulses result in rapid permeability changes in the surface membrane that are relatively homogeneous across the cell population, consistent with electroporation, while shorter pulses cause surface membrane permeability changes that are temporally delayed and heterogeneous in their magnitude.  相似文献   

16.
During the electroporation cell membrane undergoes structural changes, which increase the membrane conductivity and consequently lead to a change in effective conductivity of a cell suspension. To correlate microscopic membrane changes to macroscopic changes in conductivity of a suspension, we analyzed the effective conductivity theoretically, using two different approaches: numerically, using the finite elements method; and analytically, by using the equivalence principle. We derived the equation, which connects membrane conductivity with effective conductivity of the cell suspension. The changes in effective conductivity were analyzed for different parameters: cell volume fraction, membrane and medium conductivity, critical transmembrane potential, and cell orientation. In our analysis we used a tensor form of the effective conductivity, thus taking into account the anisotropic nature of the cell electropermeabilization and rotation of the cells. To determine the effect of cell rotation, as questioned by some authors, the difference between conductivity of a cell suspension with normally distributed orientations and parallel orientation was also calculated, and determined to be <10%. The presented theory provides a theoretical basis for the analysis of measurements of the effective conductivity during electroporation.  相似文献   

17.
Electrical impedance spectroscopy was used to characterize the cell environment of multilayered cell cultures (MCCs), a culture system in which cells are grown on a permeable support membrane to form a thick disc of cells with tumor-like properties. Cultures were grown using SiHa tumor cells as well as V79 wild-type cells and V79/DOX cells cultivated to exhibit multidrug resistance. Electrical impedance measurements were made on MCCs over a frequency range of 0. 1 kHz to 1 MHz. Data analysis using a simple electrical model for the cell environment yielded estimates for parameters related to the intra- and extracellular resistance and net membrane capacitance, which were then related to MCC thickness. The extracellular fraction and tortuosity of the MCCs were determined in separate experiments where the rate of diffusion and the equilibrium level of C14-inulin, which does not penetrate the cell membrane, was measured within MCCs. Impedance measurements predicted the barrier to diffusion posed by the extracellular space of MCCs to be roughly two times greater than that inferred from the C14-inulin experiments. However, the relative ranking of the three cell types used to grow MCCs was similar for the two methods. Results indicate that impedance spectroscopy is well suited for use in characterizing the MCC cell environment, offering a fast, nondestructive method for monitoring cell culture growth and integrity.  相似文献   

18.
The aim of the study was to investigate the feasibility of using irreversible electroporation (EP) as a microbial cell disruption technique to extract intracellular lipid within short time and in an eco‐friendly manner. An EP circuit was designed and fabricated to obtain 4 kV with frequency of 100 Hz of square waves. The yeast cells of Lipomyces starkeyi (L. starkeyi) were treated by EP for 2‐10 min where the distance between electrodes was maintained at 2, 4, and 6 cm. Colony forming units (CFU) were counted to observe the cell viability under the high voltage electric field. The forces of the pulsing electric field caused significant damage to the cell wall of L. starkeyi and the disruption of microbial cells was visualized by field emission scanning electron microscopic (FESEM) image. After breaking the cell wall, lipid was extracted and measured to assess the efficiency of EP over other techniques. The extent of cell inactivation was up to 95% when the electrodes were placed at the distance of 2 cm, which provided high treatment intensity (36.7 kWh m?3). At this condition, maximum lipid (63 mg g?1) was extracted when the biomass was treated for 10 min. During the comparison, EP could extract 31.88% lipid while the amount was 11.89% for ultrasonic and 16.8% for Fenton's reagent. The results recommend that the EP is a promising technique for lowering the time and solvent usage for lipid extraction from microbial biomass. © 2018 American Institute of Chemical Engineers Biotechnol. Prog., 34:838–845, 2018  相似文献   

19.
We explored how the effect of plasma membrane permeabilization by nanosecond-duration electric pulses (nsEP) depends on the physical characteristics of exposure. The resting membrane resistance (R(m)) and membrane potential (MP) were measured in cultured GH3 and CHO cells by conventional whole-cell patch-clamp technique. Intact cells were exposed to a single nsEP (60 or 600 ns duration, 0-22 kV/cm), followed by patch-clamp measurements after a 2-3 min delay. Consistent with earlier findings, nsEP caused long-lasting R(m) decrease, accompanied by the loss of MP. The threshold for these effects was about 6 kV/cm for 60 ns pulses, and about 1 kV/cm for 600 ns pulses. Further analysis established that it was neither pulse duration nor the E-field amplitude per se, but the absorbed dose that determined the magnitude of the biological effect. In other words, exposure to nsEP at either pulse duration caused equal effects if the absorbed doses were equal. The threshold absorbed dose to produce plasma membrane effects in either GH3 or CHO cells at either pulse duration was found to be at or below 10 mJ/g. Despite being determined by the dose, the nsEP effect clearly is not thermal, as the maximum heating at the threshold dose is less than 0.01 degrees C. The use of the absorbed dose as a universal exposure metric may help to compare and quantify nsEP sensitivity of different cell types and of cells in different physiological conditions. The absorbed dose may also prove to be a more useful metric than the incident E-field in determining safety limits for high peak, low average power EMF emissions.  相似文献   

20.
The electrical properties of the membranes of Valoniautricularis were investigated using intracellular electrodes. Using short (0.5–1.0 ms) current pulses it was found that at a critical membrane potential difference of 0.85 V there was a large and discontinuous decrease in the membrane impedance and the slope resistance beyond this potential was virtually zero.The electrical breakdown of the membranes did not lead to global damage of the cells and after a resealing time of approx. 5 s could be repeated with identical results.Experiments with long current pulses and long bursts of pulses repeated at 1 kHz are described which show that the electrical breakdown is not due to thermal damage arising from localized heating in the membrane. Thus a dissipation of some 103–105 times the energy normally dissipated during the onset of breakdown did not lead to breakdown itself unless the critical membrane potential was exceeded.The results also show that punch-through and avalanche ionization are not likely to be important in the breakdown mechanism. The results are consitent, however, with there being a critical instability in the electro-mechanical stresses set up in the membrane at large electric field strengths.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号