首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A commercial β-glucuronidase (β-GUR) test for the rapid and economical identification of Escherichia coli was evaluated. A total of 762 clinical strains and 228 environmental isolates were studied. More than 95% of the E. coli strains were found to be β-GUR positive. Thirty-one clinical isolates of Shigella sonnei , 10 of Enterobacter cloacae , eight of Enterobacter aerogenes, nine of Citrobacter freundii and one of Salmonella enteritidis also gave positive results. The enzyme β-GUR was also detected in two environmental strains of E. cloacae and one C. freundii. A comparative study between the β-GUR test and the conventional identification system was carried out in 233 consecutive isolates of lactose positive enterobacteria. Agreement was observed in 223 cases and 190 E. coli strains were correctly identified using this test. Discrepancies were found in 10 cases: nine E. coli were β-GUR negative and one C. freundii was β-GUR positive. Escherichia coli was the only species positive for both β-GUR and indole tests. This procedure permits a rapid, easy, precise and inexpensive identification of E. coli. β-GUR positive Enterobacter strains have not previously been described.  相似文献   

2.
In 1976, Kilian and Bulow described the association of beta-glucuronidase with the genus Escherichia (97% positive) and suggested that a beta-glucuronidase assay would be a useful identification test. Since that report, papers about the sensitivity and specificity of this enzyme for the identification of Escherichia coli from clinical sources, food, seawater, potable-water supplies, and various environmental sources have appeared. A study was undertaken to determine the efficacy and specificity of the defined-substrate technology beta-glucuronidase (Colilert) assay for the identification of this species from fecal samples. A total of 460 human, 105 cow, and 55 horse E. coli isolates were tested. Results showed 95.5% beta-glucuronidase-positive isolates in 24 h and 99.5% positive after 28 h of incubation. Only one E. coli isolate was negative. There were no significant differences in the percentage of beta-glucuronidase-positive isolates among the human or animal isolates. There were no non-E. coli isolates that were positive. All subjects carried beta-glucuronidase-positive E. coli.  相似文献   

3.
A medium containing the fluorogenic substrate 4-methylumbelliferyl-beta-D-glucuronide was developed for the isolation and identification of Escherichia coli within 7.5 h and was based on the detection of beta-glucuronidase. Optimum conditions for the rapid development of fluorescent colonies were determined. The optimum temperature was 41.5 degrees C. Development of fluorescence was delayed when carbohydrates were incorporated into the medium. Water samples were used to evaluate the medium by surface plating and membrane filtration. The frequency of false-negative results was 6.1% and false-positives were 3.7% for freshwater samples. The false-positive organisms were identified as Klebsiella spp. and Shigella sonnei. The potential applications of the medium are discussed.  相似文献   

4.
In 1976, Kilian and Bulow described the association of beta-glucuronidase with the genus Escherichia (97% positive) and suggested that a beta-glucuronidase assay would be a useful identification test. Since that report, papers about the sensitivity and specificity of this enzyme for the identification of Escherichia coli from clinical sources, food, seawater, potable-water supplies, and various environmental sources have appeared. A study was undertaken to determine the efficacy and specificity of the defined-substrate technology beta-glucuronidase (Colilert) assay for the identification of this species from fecal samples. A total of 460 human, 105 cow, and 55 horse E. coli isolates were tested. Results showed 95.5% beta-glucuronidase-positive isolates in 24 h and 99.5% positive after 28 h of incubation. Only one E. coli isolate was negative. There were no significant differences in the percentage of beta-glucuronidase-positive isolates among the human or animal isolates. There were no non-E. coli isolates that were positive. All subjects carried beta-glucuronidase-positive E. coli.  相似文献   

5.
The new United States Drinking Water Regulations state that water systems must analyze for Escherichia coli or fecal coliforms on any routine or repeat sample that is positive for total coliforms. The proposed methods for the detection of E. coli are based on beta-glucuronidase activity, using the fluorogenic substrate 4-methylumbelliferyl beta-D-glucuronide (MUG). This study was conducted to determine whether beta-glucuronidase negative E. coli were present in significant numbers in environmental waters. Two hundred and forty E. coli cultures were isolated from 12 water samples collected from different environmental sources. beta-glucuronidase activity was determined using lauryl tryptose broth with MUG, EC broth with MUG, and the Autoanalysis Colilert (AC) procedure. The isolates were also evaluated by the standard EC broth gas fermentation method for fecal coliforms. The results confirm that assaying for the enzyme beta-glucuronidase utilizing the MUG substrate is an accurate method for the detection of E. coli in environmental waters.  相似文献   

6.
A strong and constitutive expression vector of Escherichia coli beta-glucuronidase with the isocitrate dehydrogenase promoter has been developed for producing a large amount of recombinant protein. More than 95% pure enzyme was obtained by a four step purification procedure-ammonium sulfate precipitation, DEAE ion-exchange chromatography, Superose 12 gel filtration, and hydroxyapatite steric ion-exchange chromatography. The overexpressed gene can produce 23 mg of pure enzyme from one liter of bacterial culture.  相似文献   

7.
AIMS: DuPont Qualicon recently developed a new PCR assay for the identification of Campylobacter jejuni and Campylobacter coli. We evaluated the selectivity and utility of this assay compared with a PCR method already in use in our laboratory. METHODS AND RESULTS: A group of 133 Campylobacter isolates from poultry carcass rinse samples were screened using the commercial PCR and standard PCR. Identical results were found for 89.5% (119/133) of the isolates. However, 10.5% (14/133) gave conflicting results suggesting mixed cultures. These 14 strains were retested by both PCR methods. Of these, 78.6% (11/14) showed identical results for both PCR methods after retesting; the results for the remaining 21.4% (3/14) again indicated mixed cultures. CONCLUSIONS, SIGNIFICANCE AND IMPACT OF STUDY: The new multiplex PCR is a rapid and accurate alternative to more conventional PCR methods. The persistence of mixed Campylobacter cultures noted in this study suggests certain strains may be very difficult to isolate clonally by standard culture methods.  相似文献   

8.
The Colilert-18 system for enumeration of total coliforms and Escherichia coli is approved by the U.S. Environmental Protection Agency for use in drinking water analysis and is also used by various agencies and research studies for enumeration of indicator organisms in fresh and saline waters. During monitoring of Pinellas County, Fla., marine waters, estimates of E. coli numbers (by Colilert-18) frequently exceeded fecal coliform counts (by membrane filtration) by 1 to 3 orders of magnitude. Samples from freshwater sites did not display similar discrepancies. Fecal coliforms, including E. coli, could be cultured from 100% of yellow fluorescent wells (denoting E. coli-positive results) inoculated with freshwater samples but could be cultured from only 17.1% of the "positive" wells inoculated with marine samples. Ortho-nitrophenyl-beta-D-galactopyranoside (ONPG)-positive or 4-methylumbelliferyl-beta-D-glucuronide (MUG)-positive noncoliform bacteria were readily cultured from Colilert-18 test wells inoculated with marine samples. Filtered cell-free seawater did not cause false positives. Coculture preparations of as few as 5 CFU of Vibrio cholerae (ONPG positive) and Providencia sp. (MUG positive) ml(-1) inoculated into Colilert-18 caused false-positive E. coli results. Salinity conditions influenced coculture results, as the concentration of coculture inoculum required to cause false positives in most wells increased from about 5 CFU ml(-1) in seawater diluted 1:10 with freshwater to approximately equal to 5,000 CFU ml(-1) in seawater diluted 1:20 with freshwater. Estimated E. coli numbers in various marine water samples processed at the 1:10 dilution ranged from 10 to 7,270 CFU.100 ml(-1), while E. coli numbers in the same samples processed at the 1:20 dilution did not exceed 40 CFU.100 ml(-1). The lower estimates of E. coli numbers corresponded well with fecal coliform counts by membrane filtration. This study indicates that assessment of E. coli in subtropical marine waters by Colilert-18 is not accurate when the recommended 1:10 sample dilution is used. The results suggest that greater dilution may diminish the false-positive problem, but further study of this possibility is recommended.  相似文献   

9.
10.
The analysis of modern data on the development of amplification test systems for the gene indication of enterohemorrhagic E. coli (EHEC) is presented. In this work the emphasis is laid on the importance of using specific primers whose nucleotide sequence is closely linked with genes controlling the key factors of EHEC pathogenicity; these factors include the determinants of the synthesis of adhesins and invasins (bfp, eae, tir), shiga-like toxins (stx1, stx2), enterohemolysin (ehx), serine protease (epsA) and specific LPS of O-antigen (rfb). The problem of using primers whose sequence is not linked with virulence genes, but which may also be used for the gene indication of E. coli O157:H7 (uid, fliC) is discussed.  相似文献   

11.
One step purification of Escherichia coli beta-glucuronidase   总被引:1,自引:0,他引:1  
C Blanco  G Nemoz 《Biochimie》1987,69(2):157-161
beta-glucuronidase was purified by affinity chromatography on thiophenyl-glucuronide coupled to Sepharose. The enzyme was more than 95% pure. This enzyme is a tetramer composed of identical 74 kDa monomers. The amino-terminal sequence determined was: NH2-Met-Leu-Arg-Pro-Val.  相似文献   

12.
Establishment of a simple and rapid multiplex PCR system for identification of the main diarrheagenic E. coli categories, including enteroaggregative E. coli, enterotoxigenic E. coli, enteropathogenic E. coli, and enterohemorrhagic E. coli, is described. This two-step multiplex PCR system allows the identification by targeting CVD432, LT, STh, STp, Eae, Bfp, Stx1, and Stx2. By applying the developed multiplex PCR system, categorization of E. coli isolates isolated from stool samples of infants with diarrhea into the main diarrheagenic E. coli categories is also shown.  相似文献   

13.
Colilert (Colilert), Readycult Coliforms 100 (Readycult), Chromocult Coliform agar ES (Chromocult), and MI agar (MI) are beta-galactosidase and beta-glucuronidase-based commercial culture methods used to assess water quality. Their analytical performance, in terms of their respective ability to detect different strains of Escherichia coli and total coliforms, had never been systematically compared with pure cultures. Here, their ability to detect beta-glucuronidase production from E. coli isolates was evaluated by using 74 E. coli strains of different geographic origins and serotypes encountered in fecal and environmental settings. Their ability to detect beta-galactosidase production was studied by testing the 74 E. coli strains as well as 33 reference and environmental non-E. coli total coliform strains. Chromocult, MI, Readycult, and Colilert detected beta-glucuronidase production from respectively 79.9, 79.9, 81.1, and 51.4% of the 74 E. coli strains tested. These 4 methods detected beta-galactosidase production from respectively 85.1, 73.8, 84.1, and 84.1% of the total coliform strains tested. The results of the present study suggest that Colilert is the weakest method tested to detect beta-glucuronidase production and MI the weakest to detect beta-galactosidase production. Furthermore, the high level of false-negative results for E. coli recognition obtained by all four methods suggests that they may not be appropriate for identification of presumptive E. coli strains.  相似文献   

14.
Evaluations of several commercial presence-absence (P-A) test kits were performed over a 6-month period in 1990 by using the Ontario Ministry of the Environment (MOE) P-A test for comparison. The general principles of the multiple-tube fermentation technique formed the basis for conducting the product evaluations. Each week, a surface water sample was diluted and inoculated into 25 99-ml dilution blanks for each of three dilutions. The inoculated dilution blanks from each dilution series were randomly sorted into sets of five. Three of these sets were inoculated into the P-A test kits or vice versa, as required. The other two sets were passed through membrane filters, and one set of five membrane filters was placed onto m-Endo agar LES to give replicate total coliform counts and the other set was placed onto m-TEC agar to give replicate fecal coliform results. A statistical analysis of the results was performed by a modified logistic transform method, which provided an improved way to compare binary data obtained from the different test kits. The comparative test results showed that three of the four commercial products tested gave very good levels of recovery and that the fourth commercial product gave only fair levels of recovery when the data were compared with the data from MOE P-A tests and membrane filter tests. P-A bottles showing positive results after 18 h of incubation that were subcultured immediately in ECMUG tubes frequently could be confirmed as containing total coliforms, fecal coliforms, or Escherichia coli after 6 h of incubation; thus, the total incubation time was only 24 h.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
A commercial gene probe assay kit for presence/absence determination of Escherichia coli in food samples has been used in the standard UK six tube format most probable number (MPN) method for enumerating E. coli in drinking water samples. Presence/absence analysis with the gene probe kit (requiring 3 h) of all MPN tubes after a 21–24 h incubation (minerals modified glutamate; 37°C) enumerated confirmed E. coli in 24–27 h which offered an improvement of up to 48 h over the standard UK MPN method. MPNs determined by the gene probe method and the standard UK method agreed in nine of the 16 water samples which were analysed and for which E. coli concentrations were within the detection limits of the six tube MPN format. This was consistent with the gene probe method detecting one E. coli in a tube. For the other seven water samples, the gene probe method registered positive only 20 of the 30 tubes which the standard UK method determined to be positive. The sensitivity of the gene probe method for drinking water samples, although encouraging, needs improvement perhaps through kit quality control procedures.  相似文献   

16.
In vitro directed evolution through DNA shuffling is a powerful molecular tool for creation of new biological phenotypes. E. coli beta-galactosidase and beta-glucuronidase are widely used, and their biological function, catalytic mechanism, and molecular structures are well characterized. We applied an in vitro directed evolution strategy through DNA shuffling and obtained five mutants named YG6764, YG6768, YG6769, YG6770 and YG6771 after two rounds of DNA shuffling and screening, which exhibited more beta-glucuronidase activity than wild-type beta-galactosidase. These variants had mutations at fourteen nucleic acid sites, resulting in changes in ten amino acids: S193N, T266A, Q267R, V411A, D448G, G466A, L527I, M543I, Q626R and Q951R. We expressed and purified those mutant proteins. Compared to the wild-type protein, five mutant proteins exhibited high beta-glucuronidase activity. The comparison of molecular models of the mutated and wildtype enzymes revealed the relationship between protein function and structural modification.  相似文献   

17.
We have previously described a microbiological process for the conversion of lactose into 3'sialyllactose and other ganglioside sugars by living Escherichia coli cells expressing the appropriate recombinant glycosyltransferase genes. In this system the activated sialic acid donor (CMP-Neu5Ac) was generated from exogenous sialic acid, which was transported into the cells by the permease NanT. Since sialic acid is an expensive compound, a more economical process has now been developed by genetically engineering E. coli K12 to be capable of generating CMP-Neu5Ac using its own internal metabolism. Mutant strains devoid of Neu5Ac aldolase and of ManNAc kinase were shown to efficiently produce 3'sialyllactose by coexpressing the alpha-2,3-sialyltransferase gene from Neisseria meningitidis with the neuC, neuB and neuACampylobacter jejuni genes encoding N-acetylglucosamine-6-phosphate-epimerase, sialic acid synthase and CMP-Neu5Ac synthetase, respectively. A sialyllactose concentration of 25 g l(-1) was obtained in long-term high cell density culture with a continuous lactose feed. This high concentration and low cost of fermentation medium should make possible to use sialylated oligosaccharides in new fields such as the food industry.  相似文献   

18.
Mucopolysaccharidosis type VII is a lysosomal storage disease resulting from a deficiency of beta-glucuronidase (BG) activity. To facilitate the investigation of mutation in the disease and provide molecular diagnostic tools for affected families, we have isolated human BG cDNA clones. The SV40-transformed human fibroblast cDNA library of Okayama and Berg [Mol. Cell. Biol. 3 (1982) 280-289] was screened with a fragment of a murine BG cDNA clone (pGUS-1). The 17 human cDNA clones (pHUG) isolated were identical by restriction mapping, varying only in length. The pHUG clones show 80% DNA sequence homology with pGUS-1 in a 198-bp PvuII-SstI restriction fragment. Both pGUS-1 and the pHUG clones contained an open reading frame (ORF) throughout the sequenced region with a predicted amino acid sequence homology of 73%. Expression in Escherichia coli of a 1150-bp fragment of pHUG-1 subcloned in pUC9 resulted in an isopropyl-thio-beta-galactoside (IPTG)-inducible 35-kDal fusion protein which was specifically immunoprecipitated by goat anti-human BG immunoglobulin G (IgG). This evidence provides direct confirmation that the pHUG cDNA clones correspond to human BG.  相似文献   

19.
A modification of the benzoylated DEAE-cellulose method of tRNA fractionation has been developed to provide a rapid and highly efficient method for the quantitative identification of multiple tryptophan, tyrosine, and phenylalanine tRNA species from E. coli aminoacylated in vivo. This method should be of particular use in physiological studies of these tRNA species.  相似文献   

20.
A medium containing a chromogenic substrate was developed for the enumeration of Escherichia coli on the basis of beta-glucuronidase activity. In this medium there was an inverse linear relationship between the log initial E. coli concentration and the time taken for the color to reach a threshold optical density of 0.05. This relationship applied even when the E. coli population contained 5% beta-glucuronidase-negative cells. Incubation at 44 degrees C reduced the time taken for color development and allowed the procedure to be used in the presence of a competitive microflora that outnumbered the E. coli population by a factor of 10(4). Sodium lauryl sulfate as an additional selective agent gave no significant improvement. In the analysis of environmental water samples, the technique gave a good correlation with a standard cultural method. The procedure shows promise as a simple method for testing the compliance of environmental samples with microbiological criteria for E. coli.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号