首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A large majority of surface plasmon resonance (SPR) sensors reported in the literature are designed to operate in the visible electromagnetic spectrum. However, the near-infrared, particularly at the telecommunications wavelength of 1550 nm, is also especially attractive for SPR sensing applications. In fact, SPR sensors operating in this region benefit from narrower resonance and deeper field penetration. In this paper, we report a theoretical and experimental study of an SPR sensor operating at a fixed wavelength of 1550 nm. The influence of the choice of metals and the interrogation methods on the sensitivity of the resulting SPR sensor is investigated. Two types of sensor chips (simple gold (Au) and bimetallic silver/Au structure) and three interrogation methods (monitoring of the position of the reflectivity minimum, the position of the centroid, and the intensity evolution of the reflectivity) are examined. We show that a refractive index resolution of 2.7?×?10?6 refractive index unit can be easily obtained, and with further optimization of the measurement system, the ultimate limit of detection is expected to be even lowered. Therefore, the approach discussed here already shows a promising potential for highly sensitive SPR sensors.  相似文献   

2.
In this paper, we report a novel wavelength interrogation-based surface plasmon resonance (SPR) system, in which a film of three Ag layers and three Au layers are alternately deposited on a Kretschmann configuration as sensing element. This multilayer film shows higher sensitivity for refractive index (RI) measurement by comparing with single Au layer structure, which is consistent with its theoretical calculation. A sensitivity range of 2056–5893 nm/RIU can be achieved, which is comparable to RI sensitivities of other wavelength-modulated SPR sensors. Compared with Ag film, this Ag/Au multilayer arrangement offers anti-oxidant protection. This SPR biosensor based on a cost-effective Ag/Au multilayer structure is applicable to the real-time detection of specific interactions and dissociation of low protein concentrations. To extend the application of this highly-sensitive metal film device, we integrated this concept on an optical fiber. The range of RI sensitivities with Ag/Au multilayer was 1847–3309 nm/RIU. This miniaturized Ag/Au multilayer-based fiber optic sensor has a broad application in chemical and biological sensing.  相似文献   

3.
Sensors based on surface plasmon resonance (SPR) allow rapid, label-free, highly sensitive detection, and indeed this phenomenon underpins the only label-free optical biosensing technology that is available commercially. In these sensors, the existence of surface plasmons is inferred indirectly from absorption features that correspond to the coupling of light into a thin metallic film. Although SPR is not intrinsically a radiative process, when the metallic coating which support the plasmonic wave exhibits a significant surface roughness, the surface plasmon can itself couple to the local photon states, and emit light. Here we show that using silver coated optical fibres, this novel SPR transducing mechanism offers significant advantages compare to traditional reflectance based measurements such as lower dependency on the metallic thickness and higher signal to noise ratio. Furthermore, we show that more complex sensor architectures with multiple sensing regions scattered along a single optical fibre enable multiplexed detection and dynamic self referencing of the sensing signal. Moreover, this alternative approach allows to combine two different sensing technologies, SPR and fluorescence sensing within the same device, which has never been demonstrated previously. As a preliminary proof of concept of potential application, this approach has been used to demonstrate the detection of the seasonal influenza A virus.  相似文献   

4.
Owing to its large surface-to-volume ratio and good biocompatibility, graphene has been identified as a highly promising candidate as the sensing layer for fiber optic sensors. In this paper, a graphene/Au-enhanced plastic clad silica (PCS) fiber optic surface plasmon resonance (SPR) sensor is presented. A sheet of graphene is employed as a sensing layer coated around the Au film on the PCS fiber surface. The PCS fiber is chosen to overcome the shortcomings of the structured microfibers and construct a more stable and reliable device. It is demonstrated that the introduction of graphene can enhance the intensity of the confined electric field surrounding the sensing layer, which results in a stronger light-matter interaction and thereby the improved sensitivity. The sensitivity of graphene-based fiber optic SPR sensor exhibits more than two times larger than that of the conventional gold film SPR fiber optic sensor. Furthermore, the dynamic response analyses reveal that the graphene/Au fiber optic SPR sensor exhibits a fast response (5 s response time) and excellent reusability (3.5% fluctuation) to the protein biomolecules. Such a graphene/Au fiber optic SPR sensor with high sensitivity and fast response shows a great promise for the future biochemical application.  相似文献   

5.

This paper deals with the development and analysis of D-Shaped photonic crystal fiber (PCF) biosensors using surface plasmon resonance (SPR). A thin metal layer is deposited on the outer flat surface of the PCF that behaves as the plasmonic material. Analyte is filled in the outermost peripheral region of metal layer. Finite element method (FEM) with perfectly matched layer (PML) is applied to analyze the proposed sensors. Mode analysis is performed on the proposed structures to evaluate various parameters of SPR-based PCF sensors. Three D-shaped PCF structures have been proposed with silver (Ag), gold (Au) and two-half layers of both (Ag-Au) on its flat surface. The first two structures are analyzed to the range of wavelength where the SPR will occur to facilitate understanding of the third structure. It is observed that the structures with one metal have only one sensitive plasmonic peak whereas the structure with two metal layers has two sensitive plasmonic peaks, making it suitable candidate for two-molecule sensing present in a sample analyte. Good sensitivities and resolutions are achieved for both plasmonic peaks.

  相似文献   

6.
A novel sensing method based on surface plasmon resonance (SPR) was developed for the highly sensitive quantification of low molecular weight (LMW) analytes (colloidal Au replacement assay). Gold nanoparticles (diameter = 20 nm) functionalized with lactosyl-poly(ethylene glycol) (PEG) were prepared and were specifically adsorbed onto a Ricinus communis agglutinin (RCA120)-immobilized SPR sensor chip surface. Subsequent injection of free d-galactose elicited the elution of the preadsorbed lactosyl-PEGylated gold nanoparticles in a manner proportional to the galactose concentration, achieving a substantial and quantitative analysis over a wide range of galactose concentrations (0.1-50 ppm). This method of d-galactose sensing through the substituted elution of preadsorbed nanoparticles from the sensor chip surface would be applicable for the highly sensitive SPR quantification of various LMW analytes, which are known to be difficult to detect by the conventional SPR sensing regime.  相似文献   

7.
In the present study, we report the first polyindole-modified metal (Au) as a glucose sensor utilizing surface plasmon resonance (SPR) technique. Polyindole (PIn) was deposited by spin coating to modify the surface of the gold disk. Sensor surface was prepared by immobilizing glucose oxidase on the polyindole-modified gold disk. Different concentrations of glucose were taken to analyze the sensor response. A change in refractive index of the film was observed due to the chemical reactions of glucose with glucose oxidase. The response of the sensor is fast and highly sensitive to low concentrations of glucose and the sensitivity increases in the range of 0.075–0.5 μM. The use of Au/polyindole (PIn/Au) substrates for SPR-based study of bio-molecular sensing has been demonstrated.  相似文献   

8.
In this paper, the coupling interaction is investigated between a metallic nanowire array and a metal film under the Kretschmann condition. The plasmonic multilayer is composed of a metallic nanowire array embedded in a polymer layer positioned above a metal film, exploiting the classical surface plasmon resonance (SPR) configuration. We analyze the influence of various structural parameters of the metallic nanowire array on the SPR spectrum of thin metal film. The results show that the coupling interactions of nanowires with the metal film can greatly affect SPR resonance wavelength and increase SPR sensitivity. The coupling strength of metallic nanowire array and metal film also impacts resonance wavelength, which can be used to adjust SPR range but have little effect on its sensitivity. The results are confirmed using a dipole coupling resonance model of metallic nanowire. We demonstrated that this nanostructured hybrid structure can be used for high sensitivity SPR monitoring in a large spectral range, which is important for advanced SPR measurement including fiber-optic SPR sensing technology.  相似文献   

9.
Surface plasmon resonance (SPR) nanosensors based on metallic nanohole arrays have been widely reported to detect binding interactions in biological specimens. A simple and effective method for constructing nanoscale arrays is essential for the development of SPR nanosensors. In this work, we report a one-step method to fabricate nanohole arrays by thermal nanoimprinting in the matrix of IPS (Intermediate Polymer Stamp). No additional etching process or supporting substrate is required. The preparation process is simple, time-saving and compatible for roll-to-roll process, potentially allowing mass production. Moreover, the nanohole arrays were integrated into detection platform as SPR sensors to investigate different types of biological binding interactions. The results demonstrate that our one-step method can be used to efficiently fabricate large-area and uniform nanohole arrays for biochemical sensing.  相似文献   

10.
A surface plasmon resonance (SPR) biosensor system was developed for immunoassay, based on the conjugates of magnetic microbeads coupling with antibody which could be trapped on the Au film firmly due to the magnetic force. The magnetic microbeads were used as the solid support for the heat shock protein 70 (Hsp 70) antibody and antibody immobilized magnetic microbeads were utilized instead of the single antibody for the determination of Hsp 70. Since the magnetic bead is coated with dextran, the antibodies and some specific biomolecular receptors can be immobilized using a variety of chemical reactions. Compared to traditional antibody immobilization on the sensing film, there is not a covalent link between the Au film and the antibody. There is a great advantage in that sensor can be stripped and reused, and the same chemistry used to derivative dextran-coated SPR sensors can be used for the magnetic bead-coated sensors. The sensing layer was formed well. Different dilution ratios (v/v) of the conjugates result in different detectable ranges. When the dilution ratios of the conjugate are 1:10 and 1:5, the lowest concentrations of Hsp 70 that can be detected are 1.50 and 0.30 microg ml(-1), respectively.  相似文献   

11.
Surface Plasmon Resonance Imaging Sensors: A Review   总被引:1,自引:0,他引:1  
Surface plasmon resonance (SPR) imaging sensors realize label-free, real-time, highly sensitive, quantitative, high-throughput biological interaction monitoring and the binding profiles from multi-analytes further provide the binding kinetic parameters between different biomolecules. In the past two decades, SPR imaging sensors found rapid increasing applications in fundamental biological studies, medical diagnostics, drug discovery, food safety, precision measurement, and environmental monitoring. In this paper, we review the recent advances of SPR imaging sensor technology towards high-throughput multi-analyte screening. Finally, we describe our multiplex spectral-phase SPR imaging biosensor for high-throughput biosensing applications.  相似文献   

12.
In this paper we report a stable, label-free, bacteriophage-based detection of Escherichia coli (E. coli) using ultra sensitive long-period fiber gratings (LPFGs). Bacteriophage T4 was covalently immobilized on optical fiber surface and the E. coli binding was investigated using the highly accurate spectral interrogation mechanism. In contrast to the widely used surface plasmon resonance (SPR) based sensors, no moving part or metal deposition is required in our sensor, making the present sensor extremely accurate, very compact and cost effective. We demonstrated that our detection mechanism is capable of reliable detection of E. coli concentrations as low as 10(3)cfu/ml with an experimental accuracy greater than 99%.  相似文献   

13.
We report a new high-throughput surface plasmon resonance (SPR) sensor based on combination of SPR imaging with polarization contrast and a spatially patterned multilayer SPR structure. We demonstrate that this approach offers numerous advantageous features including high-contrast SPR images suitable for automated computer analysis, minimum crosstalk between neighboring sensing channels and inherent compensation for light level fluctuations. Applications of a laboratory prototype of the high-throughput SPR sensor with 108 sensing channels for refractometry and biosensing are described. In refractometric experiments, the noise-limited refractive index resolution of the system has been established to be 3 x 10(-6) refractive index unit (RIU). Experimental data on detection of human choriogonadotropin (hCG) suggest that in conjunction with monoclonal antibodies against hCG, the reported SPR imaging sensor is capable of detecting hCG at concentrations lower than 500 ng/ml.  相似文献   

14.
A novel polymer, poly(procainamide), PPA, containing numerous binding sites for cholinesterases was synthesized as a recognition layer for butyryl cholinesterase (BuChE) interaction with the ligand procainamide, utilizing TSM and SPR sensors. The polymer was synthesized by the reaction of methacryloyl chloride and procainamide followed by radical polymerization. Sensor surfaces (Au or SiO(2)) were spin-coated by the polymer solution to form thin layers. Binding of BuChE was found to be sensitive to the drying procedure of the polymer layer. The binding of BuChE to the polymer coated sensors was monitored on-line by following the response of thickness shear mode (TSM) and surface plasmon resonance (SPR) sensors. Binding of BuChE to PPA-coated TSM sensors were shown to follow a Langmuir isotherm giving association constant 3.4x10(6) M(-1).  相似文献   

15.
In this study, we report a simple, low-cost surface plasmon resonance (SPR)-sensing cartridge based on a loop-mediated isothermal amplification (LAMP) method for the on-site detection of the hepatitis B virus (HBV). For LAMP detection, a SPR based LAMP sensing system (SPRLAMP) was constructed, including a novel SPRLAMP sensing cartridge integrating a polymethyl methacrylate (PMMA) micro-reactor with a polycarbonate (PC)-based prism coated with a 50 nm Au film. First, we found that the change of refractive index of the bulk solution was approximately 0.0011 refractive index (RI) units after LAMP reaction. The PC-based prism's linearity and thermal responses were compared to those of a traditional glass prism to show that a PC-based prism can be used for SPR measurement. Finally, the HBV template mixed in the 10 μl LAMP solution could be detected by SPRLAMP system in 17 min even at the detection-limited concentration of 2 fg/ml. We also analyzed the correlation coefficients between the initial concentrations of HBV DNA templates and the system response (ΔRU) at varying amplification times to establish an optimal amplification time endpoint of 25 min (R(2)=0.98). In conclusion, the LAMP reaction could be detected with the SPRLAMP sensing cartridge based on direct sensing of the bulk refractive index.  相似文献   

16.
This study reports a microfluidic chip integrated with an arrayed immunoassay for surface plasmon resonance (SPR) phase imaging of specific bio-samples. The SPR phase imaging system uses a surface-sensitive optical technique to detect two-dimensional (2D) spatial phase variation caused by rabbit immunoglobulin G (IgG) adsorbed on an anti-rabbit IgG film. The microfluidic chip was fabricated by using micro-electro-mechanical-systems (MEMS) technology on glass and polydimethylsiloxane (PDMS) substrates to facilitate well-controlled and reproducible sample delivery and detection. Since SPR detection is very sensitive to temperature variation, a micromachine-based temperature control module comprising micro-heaters and temperature sensors was used to maintain a uniform temperature distribution inside the arrayed detection area with a variation of less than 0.3 degrees C. A self-assembled monolayer (SAM) technique was used to pattern the surface chemistry on a gold layer to immobilize anti-rabbit IgG on the modified substrates. The microfluidic chip is capable of transporting a precise amount of IgG solution by using micropumps/valves to the arrayed detection area such that highly sensitive, highly specific bio-sensing can be achieved. The developed microfluidic chips, which employed SPR phase imaging for immunoassay analysis, could successfully detect the interaction of anti-rabbit IgG and IgG. The interactions between immobilized anti-rabbit IgG and IgG with various concentrations have been measured. The detection limit is experimentally found to be 1 x 10(-4)mg/ml (0.67 nM). The specificity of the arrayed immunoassay was also explored. Experimental data show that only the rabbit IgG can be detected and the porcine IgG cannot be adsorbed. The developed microfluidic system is promising for various applications including medical diagnostics, microarray detection and observing protein-protein interactions.  相似文献   

17.
A highly sensitive and selective method for colorimetric sensing of sulfide anions in aqueous solutions is illustrated. The sensing mechanism is based on quick crystallization from Ag to Ag2S in the presence of sulfide anions which alter the dielectric properties of the Au/Ag core/shell nanorods. The longitudinal surface plasmon resonance peak of the Au/Ag nanorods at about 686 nm undergoes a redshift and the color of the nanorod solution also changes from light green to purple. Sulfide ions at a concentration of 4.0 μM (1.3 ppb) can be detected visually and a sensitivity of 0.5 μM (167 ppt) is achieved by Vis–near-infrared spectrophotometry. Compared to other plasmonic sensors, our Au/Ag nanorod probe does not require surface modification while exhibiting high stability and robustness under different pH conditions. This simple and cost-effective sensing platform provides a rapid and convenient detection for sulfide anions at concentrations far below the hazardous limit in aqueous media.  相似文献   

18.
A technique is proposed to extend the application of surface-plasmon-based spectroscopy into the mid-infrared spectral regime, which is of substantial interest in the field of chemical analysis and biosensing. Surface plasmons can be excited for wavelengths of the order of 6???m at corrugated waveguides for a given combination of materials and thicknesses, and for refractive indices of the surrounding medium corresponding to those of organic solvents. This approach can easily be extrapolated to other values of any of these parameters. Based on these considerations, a new generation of mid-IR SPR sensors can be developed with a diverse range of potential applications in chem/bio sensing.  相似文献   

19.
We design terahertz (THz) surface-plasmon-resonance (SPR) sensors using a ferroelectric polyvinylidene fluoride (PVDF) thin layer for biological sensing. The reflectivity properties based on SPR are described using transfer matrix method (TMM) and numerically simulated using finite-difference time domain (FDTD) method. The sensing characteristics of the structure are systematically analyzed through the examination of the reflectivity spectrum. The results reveal that the pronounced SPR resonance peak has quasi-linear relationship with the refractive index variation of the material under investigation. Through analyzing and optimizing the structural parameters of the THz SPR sensor, we achieved the theoretical value of the refractive index detection sensitivity as high as 0.393 THz/unit change of refractive index (RIU) for a 20-μm-thick liquid sample with a 10-μm PVDF layer. This work shows great promise toward realizing a THz SPR sensor with high sensitivity for identifying the signatures of biological fluid sample.  相似文献   

20.
Au nanorods forming carpet-like structures have been fabricated by electrochemical methods in mesoporous silicon templates. The anodically grown monodisperse pores on Si (100) were used to cathodically grow the Au structures from complexated Au solutions. Such structures feature selective absorption of light in the visible/near infrared wavelength range that can be tuned by controlling the aspect ratio and dielectric surrounding media. In the present work, the visible light absorption of Au structures has been studied and correlated with the light absorption of ideal structures with increasing complexity. According to these simulations, the observed selective light absorption arises from the anisotropic surface plasmon resonance (SPR) of the rods and a secondary SPR of isolated Au nanoparticles adsorbed on the rods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏