首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
A study was undertaken to explore the molecular mechanisms underlying control of HCV infection in blood donors in China. Factors including clinical information, anti-HCV reactivity (S/CO), IFN-α and IFN-γ, viral loads and genotypes were correlated with 160 index plasma samples at three statuses of 45 recovered, 76 chronic or 39 false positive anti-HCV reactive blood donors. The spontaneous recovery rate was 37.2%. Viral loads of 76 HCV plasmas ranged between 59.8 IU/ml and 2.43 × 106 IU/ml (median 3.67 × 104 IU/ml). Genotypes 1, 2, 3 and 6 of 63 HCV strains were identified phylogenetically. Recovered donors were significantly younger (p = 0.002) and had lower level IFN-γ (p = 0.001) than chronically HCV infected donors. Circulating levels of IFN-α and IFN-γ were higher in those with low viral load and were low in middle or high viral load samples. The ratio of IFN-α to IFN-γ (IFN-α/γ) was significantly positively correlated with viral load (p = 0.037), and viral load was inversely correlated with IFN-γ in chronic HCV infection regardless of genotype. The study revealed clearly different relationships between IFN-α and IFN-γ in relation to viral load in HCV. A novel measure of IFN-α/γ ratio could be a new approach to evaluate long term outcome of HCV infection.  相似文献   

2.
MethodsThe performance of DBS in HBV quantification was investigated using a modified commercial test (Abbott RealTime HBV assay). Paired DBS and plasma samples were collected from an HBV positive cohort in Addis Ababa, Ethiopia. DBS were stored at ambient temperature for 4–39 days before shipment to the laboratory.ResultsTwenty-six paired samples were selected covering the total range of quantification, from 2.14 log IU/ml to >7 log IU/ml. HBV was detected in 21 of 21 (100%) DBS from patients with a corresponding plasma viral load above 2.70 log IU/ml. The mean difference between plasma and DBS was 0.59 log IU/ml, and the correlation was strong (R2 = 0.92). In stability studies there was no significant change in DBS viral load after storage at room temperature for up to 12 weeks.ConclusionsThis study suggests that DBS can be a feasible and reliable alternative to plasma for quantification of HBV in resource-limited settings. DBS can expand access to antiviral treatment for patients in low- and middle-income countries.  相似文献   

3.

Background

Detection and quantification of hepatitis C virus (HCV) RNA is integral to diagnostic and therapeutic regimens. All molecular assays target the viral 5′-noncoding region (5′-NCR), and all show genotype-dependent variation of sensitivities and viral load results. Non-western HCV genotypes have been under-represented in evaluation studies. An alternative diagnostic target region within the HCV genome could facilitate a new generation of assays.

Methods and Findings

In this study we determined by de novo sequencing that the 3′-X-tail element, characterized significantly later than the rest of the genome, is highly conserved across genotypes. To prove its clinical utility as a molecular diagnostic target, a prototype qualitative and quantitative test was developed and evaluated multicentrically on a large and complete panel of 725 clinical plasma samples, covering HCV genotypes 1–6, from four continents (Germany, UK, Brazil, South Africa, Singapore). To our knowledge, this is the most diversified and comprehensive panel of clinical and genotype specimens used in HCV nucleic acid testing (NAT) validation to date. The lower limit of detection (LOD) was 18.4 IU/ml (95% confidence interval, 15.3–24.1 IU/ml), suggesting applicability in donor blood screening. The upper LOD exceeded 10−9 IU/ml, facilitating viral load monitoring within a wide dynamic range. In 598 genotyped samples, quantified by Bayer VERSANT 3.0 branched DNA (bDNA), X-tail-based viral loads were highly concordant with bDNA for all genotypes. Correlation coefficients between bDNA and X-tail NAT, for genotypes 1–6, were: 0.92, 0.85, 0.95, 0.91, 0.95, and 0.96, respectively; X-tail-based viral loads deviated by more than 0.5 log10 from 5′-NCR-based viral loads in only 12% of samples (maximum deviation, 0.85 log10). The successful introduction of X-tail NAT in a Brazilian laboratory confirmed the practical stability and robustness of the X-tail-based protocol. The assay was implemented at low reaction costs (US$8.70 per sample), short turnover times (2.5 h for up to 96 samples), and without technical difficulties.

Conclusion

This study indicates a way to fundamentally improve HCV viral load monitoring and infection screening. Our prototype assay can serve as a template for a new generation of viral load assays. Additionally, to our knowledge this study provides the first open protocol to permit industry-grade HCV detection and quantification in resource-limited settings.  相似文献   

4.
Hepatitis C virus (HCV) infection is a major public health problem with about 1.75 million new HCV cases and 71 million chronic HCV infections worldwide. The study aimed to evaluate clinical, serological, molecular, and liver markers to develop a mathematical predictive model for the quantification of the HCV viral load in chronic HCV infected patients. In this cross‐sectional study, blood samples were taken from 249 recently diagnosed HCV‐infected subjects and were tested for liver condition, viral genotype, and HCV RNA load. Receiver operating characteristics (ROC) curves and multiple linear regression analysis were used to predict the HCV‐RNA load. Genotype 3 followed by genotype 1 were the most prevalent genotypes in Mashhad, Northeastern Iran. The maximum levels of viral load were detected in the mixed genotype group, and the lowest levels in the undetectable genotype group. The log of the HCV viral load was significantly associated with thrombocytopenia and higher serum levels of alanine transaminase (ALT). In addition, the log HCV RNA was significantly higher in patients with arthralgia, fatigue, fever, vomiting, or dizziness. Moreover, genotype 3 was significantly associated with icterus. A ROC curve analysis revealed that the best cut‐off points for serum levels of aspartate aminotransferase (AST), ALT, and alkaline phosphatase (ALP) were >31, >34, and ≤246 IU/L, respectively. Sensitivity, specificity, and positive predictive values for AST were 87.7%, 84.36%, and 44.6%, for ALT they were 83.51%, 81.11%, and 36%, and for ALP were 72.06%, 42.81%, and 8.3%, respectively. A mathematical regression model was developed that could estimate the HCV‐RNA load. Regression model: log viral load = 7.69 ? 1.01 × G3 ? 0.7 × G1 + 0.002 × ALT ? 0.86 × fatigue.  相似文献   

5.
Follow-up of chronically infected HCV patients is the primary clinical goal in therapy administration. In the absence of an HCV vaccine, the timely monitoring of HCV viral load combined with the information of the viral genotype could contribute to patient disease management. A LightCycler Real Time RT-PCR assay was developed and optimized allowing rapid and accurate quantification of HCV RNA over an extended dynamic range using a single human reference standard. A total of 5,096 plasma samples, collected over almost 5 years, were tested and HCV RNA was quantified in 2,435 samples with levels ranging from 5.7x10(1) to 2.52x10(9) IU/ml. The precision and reproducibility of the test are documented by various inter-assay parameters of the reference standard obtained in 409 RT-PCR runs. This Real Time RT-PCR protocol uses the LightCycler cDNA amplicons for direct sequence analysis and reduces the sequencing time to approximately 3 hours. Nearly all HCV genotypes were identified. Viral sequences showed a similarity level close to 100%, independently from the viral load, while the LightCycler melting temperature analysis did not correlate with HCV genotypes. All this makes the LightCycler Real Time RT-PCR protocol a suitable tool for the diagnosis and monitoring of HCV infections.  相似文献   

6.
Hepatitis C virus (HCV) infection is thought to mostly become chronic and rarely resolves. HCV infection was serologically screened in 4,984 samples from Ghanaian blood donors, and 1.3% prevalence was found. At least 53% of confirmed anti-HCV carriers had no detectable viral RNA and were considered to have cleared the virus and recovered from the infection. Confirmation was authenticated by the presence of antibodies specific to at least two viral antigens, mostly NS3 and E2. Reactivity to HCV core antigens was lower in Ghanaian than United Kingdom blood donors. The minority of chronically infected donors carried a viral load significantly lower than an unselected comparative group of United Kingdom blood donors (2.5 x 10(5) versus 2.9 x 10(6) IU/ml; P = 0.004). HCV genotype 2 was largely predominant (87%). Sequence clustering was similarly broad in the E1/E2 and NS5 regions. The phylogenetic diversity and the incapacity to distinguish subtypes within genotype 2 in our and others' West African strains suggested that West Africa may be the origin of HCV genotype 2. The genetic diversity extended to the identification of strains clearly separated from known subtypes of genotype 2 and genotype 1. One strain appears to be part of a new HCV genotype. HCV infection in Ghana is characterized by a high rate of recovery and the predominance of broadly divergent genotype 2 strains.  相似文献   

7.
A HPLC method using an anion exchange column was developed for the quantification of baculovirus particles. To properly detect the virus eluting from the column, a nucleic acid dye was used to amplify the signal projected by the virus. The viral genome was labeled by incubating the virus with SYBR Green I at 37°C for a minimum of 1h. The virus was specifically eluted from the contaminants in 8.9 min at a NaCl concentration of 480 mM NaCl (in 20 mM Tris-HCl, pH 7.5). The total run time of the method was 25 min. The method resulted in a linear response from 1×10(8) to 5.0×10(10)viral particles (VP/ml). The detection limit was 3.0×10(7) and the quantification limit was 1×10(8)VP/ml. The intra-assay precision was <10% for both purified and crude virus preparations whereas the inter-assay precisions were <5% and <10% for purified and crude virus preparations, respectively. The recovery/accuracy of the method ranged from 78 to 101%. This method is a robust monitoring tool to facilitate research activities with baculovirus vector and accelerate development of baculovirus-based processes for manufacturing of biologics.  相似文献   

8.
One important issue related to Hepatitis C virus (HCV) RNA nucleic acid amplification testing (NAT) is the storage conditions of plasma samples in order to obtain reliable results. Many authors have reported that the storage conditions could affect the RNA stability and, hence, HCV RNA detection. We have studied HCV RNA stability in plasma samples after storage at different temperatures (-70, -20, 5 and 25 degrees C). Samples containing different HCV titres were stored and analysed by qualitative or quantitative NAT techniques at defined time points. At -20 degrees C, samples containing high HCV RNA titres were followed-up during approximately 2.6-2.7 years, samples with intermediate concentrations during approximately 1 year and samples with 100 International Units/millilitre (IU/ml) during 2.5 years. Independently of the HCV RNA concentration, the results show absence of decay in HCV RNA detectability. Samples stored at 25 degrees C maintain their HCV RNA titre during 14 days and samples at 5 degrees C were stable for at least 3 months.  相似文献   

9.
The implementation of nucleic acid amplification technology (NAT) for detection of HCV, HIV-1 and HBV has undoubtedly contributed to the viral safety of blood, reducing the window period. One important matter related to the stability of RNA/DNA is the effect of the storage conditions on samples. In a previous work, we studied the stability of HCV RNA in plasma samples after storage at different temperatures. This work is an update on the follow-up of a sample containing 100 IU/ml HCV RNA for 5 years at -20 degrees C, showing no decrease in the initial titre. The nucleic acid stability of other viruses, such as HIV-1 and HBV, has also been studied. At -20 degrees C, samples containing HIV-1 were followed up for approximately 3 years and the results obtained show no decay in HIV-1 RNA detectability. Regardless of the HIV-1 RNA concentration, samples stored at 5 degrees C maintain their titre for at least 14 days. At 25 degrees C, the HIV-1 RNA half-life was determined at nearly 7 days. The HBV DNA, at 5 degrees C and 25 degrees C, is stable for at least 28 days, regardless of the initial titre.  相似文献   

10.
目的:研究I b型慢性丙肝患者血清IL-10、IL-12水平与HCV-RNA载量的关系,探讨难治性丙肝的免疫发病机制。方法:选取HCV-RNA阳性的I b型慢性丙肝患者48例,依据病毒载量将其分为三个组,低病毒载量组(1.0*103IU/mL1.0*106IU/mL)13例,另选HCV-RNA阴性的慢性HCV感染者15例,健康献血员15例作为对照组;应用ELISA法检测所有研究对象的血清IL-10、IL-12水平。结果:慢性丙肝患者外周血IL-10水平显著高于健康献血员(P=0.003),IL-12水平低于健康献血员(P=0.045);随着HCV-RNA载量的升高,HCV-RNA阳性的I b型慢性患者外周血IL-10水平逐渐升高,组间比较差异具有统计学意义(F=18.65,P=0.000);血清HCV-RNA载量与血清IL-10水平呈正相关(相关系数r=0.71,P=0.000),与血清IL-12水平无相关性(P=0.479)。结论:慢性HCV感染者与患者的细胞免疫均倾向于TH2型;I b型慢性丙肝患者外周血IL-10水平与HCV-RNA病毒载量呈正相关。  相似文献   

11.
HIV-1 viral load testing from 51 patients was compared in plasma samples simultaneously processed and stored in primary Vacutainer plasma preparation tubes (PPTs) and PPT sample aliquots transferred in secondary tubes before freezing, using RT-PCR quantification with an ultrasensitive method (the Roche AMPLICOR HIV-1 MONITOR). We concluded that freezing the primary sample in the PPT collection tube can artificially elevate the HIV-1 viral load. We therefore store samples as frozen aliquots in a second tube.  相似文献   

12.
13.
A fast, simple, and a reliable high-performance liquid chromatography linked with electrochemical detector (HPLC-ECD) method for the assessment of lipoic acid (LA) and dihydrolipoic acid (DHLA) in plasma was developed using naproxen sodium as an internal standard (IS) and validated according to standard guidelines. Extraction of both analytes and IS from plasma (250 μl) was carried out with a single step liquid-liquid extraction applying dichloromethane. The separated organic layer was dried under stream of nitrogen at 40°C and the residue was reconstituted with the mobile phase. Complete separation of both compounds and IS at 30°C on Discovery HS C18 RP column (250 mm × 4.6 mm, 5 μm) was achieved in 9 min using acetonitrile: 0.05 M phosphate buffer (pH 2.4 adjusted with phosphoric acid) (52:48, v/v) as a mobile phase pumped at flow rate of 1.5 ml min(-1) using electrochemical detector in DC mode at the detector potential of 1.0 V. The limit of detection and limit of quantification for lipoic acid were 500 pg/ml and 3 ng/ml, and for dihydrolipoic acid were 3 ng/ml and 10 ng/ml, respectively. The absolute recoveries of lipoic acid and dihydrolipoic acid determined on three nominal concentrations were in the range of 93.40-97.06, and 93.00-97.10, respectively. Similarly coefficient of variations (% CV) for both intra-day and inter-day were between 0.829 and 3.097% for lipoic acid and between 1.620 and 5.681% for dihydrolipoic acid, respectively. This validated method was applied for the analysis of lipoic acid/dihydrolipoic acid in the plasma of human volunteers and will be used for the quantification of these compounds in patients with oxidative stress induced pathologies.  相似文献   

14.
Hepatitis C virus remained a public health problem with approximately half of the patients untreated and undiagnosed. Chronic HCV is a leading cause of cirrhosis, fibrosis, hepatocellular carcinoma and other hepatic morbidities. Active HCV has a prevalence rate of about 1% (71 million). By July, 2019, 10 million population of Pakistan was declared to have active HCV infection. According to World Health Organization, 23,720 people died of hepatitis-related complexities in Pakistan in 2016. Individuals with certain types of ABO blood groups were more susceptible to diverse kinds of infections. For instance, blood types A and AB predisposed individuals to severe malaria, while type O conferred resistance to the many of the protozoan agent.This study was designed to explore the association of hepatitis C viremia to blood groups, Rh factors, age and gender distribution among Pakistani population. Total 246 participants were screened for HCV in Taqwa diagnostics laboratory, Multan and 200 were found positive. They were divided into 4 groups on the basis of their age. First group included patients ranging from 17 to 25 (52), second, third and fourth group included patients from 26 to 34 (92), 35 to 43 (42) and 44 to above (14) respectively. Confirmed Hepatitis C patients were subjected to analysis of blood group, Rh factor and viral load. Results demonstrated that patients having ‘O’ blood group (60.37%) were reported for high viral load than any of the other blood groups in the patients of Southern Punjab, Pakistan. Furthermore, Rh-negative factor (26.42) was associated with high viral load than that of the Rh-positive factor (73.58). Disclosure practiced that age group (26–34) was reported for the high viral load than that of the any other group of this study. Females were more aggressively affected by HCV Viremia than male because the mean viral load among the females was higher than that of the males. Greater social awareness and gender-sensitive healthcare is necessary to improve the experiences of patients with HCV.  相似文献   

15.
We describe a novel microarray-based approach for simultaneous identification and quantification of human immunodeficiency virus type 1 (HIV-1) and hepatitis B and C viruses (HBV and HCV) in donor plasma specimens. The method is based on multiplex real-time RT-PCR performed within the microarray hydrogel pads. Double-stranded amplification products are simultaneously detected using nonspecific SYBR Green I dye due to the reaction run in separate pads bearing 5'-immobilized specific primers. Both the sensitivity and specificity of the assay, based on 132 blood specimens analyzed, were 100% (56, 26, and 8 specimens were seropositive to HBV HCV and HIV-1, respectively; 22 were positive to both HIV-1 and HCV and 2 positive to all three viruses; 18 samples were pathogen-negative). The dynamic range of the quantitative analysis covered a six-order interval ranging from 100 to 106 genome equivalents per assay. The 95% detection limits were 14 gEq for HIV-1, 10 gEq (1.7 IU) for HBV, and 15 gEq (7.5 IU) for HCV per assay. The proposed approach is considered to be versatile and could be adapted for simultaneous identification and quantification of numerous genetic targets.  相似文献   

16.
目的:建立同时实现乙型肝炎病毒(hepatitisBvirus,HBV)、丙型肝炎病毒(hepatitisCvirus,HCV)、艾滋病病毒(humanImmunodeficiencyVirus,HIV)检测的多重核酸筛查系统。方法:以HBV、HCV、HIV的保守序列为模板设计特异性引物和探针,通过核酸自动提取系统结合一步法RT-PCR技术平台,优化相关反应体系和条件,建立多重多色实时荧光PCR检测血源性传播病毒的核酸筛查系统。将该系统用于101387例血浆样本的筛查。结果:本研究建立的核酸筛查系统特异性好,HBV灵敏度可以达到20IU/ml,HCV灵敏度可以达到100IU/ml,HIV灵敏度可以达到50IU/mL。结论:本研究建立的核酸筛查系统具有高度自动化、高灵敏度、低成本等特点,适合我国血站系统推广使用。  相似文献   

17.
This paper describes sensitive and reliable determination of midazolam (MDZ) and its major metabolite 1'-hydroxymidazolam (1-OHMDZ) in human plasma by liquid chromatography-mass spectrometry (LC-MS) with a sonic spray ionization (SSI) interface. MDZ, 1-OHMDZ and diazepam as an internal standard were extracted from 1ml of alkalinized plasma using n-hexane-chloroform (70:30, v/v). The extract was injected into an analytical column (YMC-Pak Pro C(18), 50mmx2.0mmi.d.). The mobile phase for separation consisted of 10mM ammonium acetate and methanol (50:50, v/v) and was delivered at a flow-rate of 0.2ml/min. The drift voltage was 100V. The sampling aperture was heated at 120 degrees C and the shield temperature was 260 degrees C. The total time for chromatographic separation was less than 16min. The validated concentration ranges of this method were 0.25-50ng/ml for both MDZ and 1-OHMDZ. Mean recoveries were 93.6% for MDZ and 86.6% for 1-OHMDZ. Intra- and inter-day coefficient variations were less than 6.5 and 5.5% for MDZ, and 6.1 and 5.7% for 1-OHMDZ at 0.3, 4, 20 and 40ng/ml. The limits of quantification were 0.25ng/ml for both MDZ and 1-OHMDZ. This method was sensitive and reliable enough for pharmacokinetic studies on healthy volunteers, and was applied for the measurement of CYP3A activity in humans after an intravenous (1mg) and a single-oral administration (2mg) of subtherapeutic MDZ dose.  相似文献   

18.
A simple, selective, and sensitive multiparameter fluorescence activated cell sorting method utilizing density gradient centrifugation and magnetic antibody cell sorting was developed and validated for the determination of phosphorylated extracellular-signal-regulated kinase (pERK) and DNA in circulating tumor cells (CTCs). Cell preparation tubes (CPT) were used for peripheral blood collection and density gradient centrifugation, followed by phosphorylation of ERK with epidermal growth factor (EGF). After fixation with formaldehyde and methanol, magnetic anti epithelial cell adhesion molecule (EpCAM) micro-beads were used for the selective isolation of CTCs from the background, consisting of peripheral blood mononuclear cells and platelets. Subsequently, samples were stained with Hoechst 33342, and fluorescent antibodies against EpCAM, CD45, and pERK. Flow cytometry was used for identification and enumeration of CTCs and determination of their pERK and DNA content. The validation parameters included specificity, recovery, linearity, precision, sensitivity, and stability. The lower limit of quantification was two CTCs per 8 ml peripheral blood. Samples were stable for 4 months in storage at -80°C. The applicability of the method was demonstrated by successful enumeration of CTCs, and the determination of DNA, and pERK before and after stimulation with EGF in 8 ml peripheral blood samples from patients with metastatic cancer.  相似文献   

19.
The aim of this study was to determine in patients with HCV genotype 2 or 3 the performance at week 4 of two assays with different sensitivities for HCV RNA detection, for the prediction of SVR and stratification for treatment duration (14 and 24 weeks). Recruitment was from two trials comparing 14 and 24 weeks treatment to patients with rapid virological response (RVR) (n = 550). RVR was originally defined as HCV RNA <50 IU/ml at week 4. Patients with an available frozen plasma sample drawn at week 4 and with follow-up data week 24 post-treatment were included (n = 429). HCV-RNA was prospectively measured with COBAS Amplicor V2, Roche (CA) (lower detection limit 50 IU/ml) and retrospectively assessed with VERSANT HCV-RNA Qualitative Assay, Siemens (TMA) (lower limit detection 10 IU/ml). Genotype 3 was present in 80% and genotype 2 in 20%. A SVR was achieved in 82%. At week 4 HCV-RNA was undetectable in 74.8% and 63% of serum samples tested with CA and TMA, respectively. CA undetectable/TMA positive was observed in 61/341 (18%) of the samples. In genotype 3 patients a relapse was seen in 9% of the patients with both CA and TMA undetectable and in 25% of the patients who were CA undetectable/TMA positive (p = 0.006). In patients allocated to 14 weeks treatment a relapse was observed in 11% of TMA undetectable patients and 26% of TMA positive (p = 0.031). In genotype 2 patients treated for 14 weeks relapse was observed in 6% of the patients with both CA and TMA undetectable week 4. Assays with high sensitivity for HCV RNA identifies patients at week 4 with high risk of virological relapse. We recommend that patients with genotype 3 and detectable HCV RNA at levels below 50 IU/ml do not receive truncated therapy with pegIFN and ribavirin.  相似文献   

20.
The human polyomavirus BK (BKV) is wide-spread pathogen, associated with urogenital tract disorders or even nephropathy in immunosuppressed patients. Nowadays molecular detection by real-time PCR (qPCR) is recognized as a method-of-choice for detecting human polyomaviruses in clinical samples. The aim of the study was development of real-time PCR assay for detection and quantification of polyomavirus BK DNA in clinical samples, using specific primers targeting a viral DNA VP3 gene and a TaqMan hydrolyzing probe. The analytical sensitivity of assay was tested using serial dilutions of BKV DNA in range between 13500 and 15 copies/ml. 27 urine samples and 23 plasma samples taken from a group of 22 adult recipients of allogeneic HSCT were tested for the presence of polyomavirus BK in the LightCycler system. Described in-house real-time PCR assay detected BKV DNA in 8 specimens (6 urine and 2 plasma). Detected average viral load was 170 copies/ml for plasma and 1250 copies/ml for urine samples, respectively. The results of this study show that developed TaqMan-based probe qPCR assay is very reliable and valuable for detection and quantification of BKV DNA, both in urine and plasma samples. These data, combined with its rapid turnaround time for results and decreased hands-on time, make the LightCycler PCR assay highly suitable for the rapid diagnostics of polyomavirus BK infections in the clinical laboratory.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号