首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Structural and functional imaging with carbon nanotube AFM probes   总被引:11,自引:0,他引:11  
Atomic force microscopy (AFM) has great potential as a tool for structural biology, a field in which there is increasing demand to characterize larger and more complex biomolecular systems. However, the poorly characterized silicon and silicon nitride probe tips currently employed in AFM limit its biological applications. Carbon nanotubes represent ideal AFM tip materials due to their small diameter, high aspect ratio, large Young's modulus, mechanical robustness, well-defined structure, and unique chemical properties. Nanotube probes were first fabricated by manual assembly, but more recent methods based on chemical vapor deposition provide higher resolution probes and are geared towards mass production, including recent developments that enable quantitative preparation of individual single-walled carbon nanotube tips [J. Phys. Chem. B 105 (2001) 743]. The high-resolution imaging capabilities of these nanotube AFM probes have been demonstrated on gold nanoparticles and well-characterized biomolecules such as IgG and GroES. Using the nanotube probes, new biological structures have been investigated in the areas of amyloid-beta protein aggregation and chromatin remodeling, and new biotechnologies have been developed such as AFM-based haplotyping. In addition to measuring topography, chemically functionalized AFM probes can measure the spatial arrangement of chemical functional groups in a sample. However, standard silicon and silicon nitride tips, once functionalized, do not yield sufficient resolution to allow combined structural and functional imaging of biomolecules. The unique end-group chemistry of carbon nanotubes, which can be arbitrarily modified by established chemical methods, has been exploited for chemical force microscopy, allowing single-molecule measurements with well-defined functionalized tips.  相似文献   

2.
The performance of a single-walled carbon nanotube:graphite-based electrode, prepared by mixing single-walled carbon nanotubes (SWCNTs) and graphite powder, is described. The resulting electrode shows an excellent behavior for the redox of caffeic acid (CA), an important biological molecule. Due to the existing resemblance between electrochemical and biological reactions, it can be assumed that the oxidation mechanisms on the electrode and in the body share similar principles. SWCNT:graphite-based electrode presents a significant decrease in the overvoltage for the CA oxidation as well as a dramatic improvement in the reversibility of the CA redox behavior in comparison with the graphite-based and glassy carbon (GC) electrodes.  相似文献   

3.
A new glucose biosensor has been fabricated by immobilizing glucose oxidase into a sol-gel composite at the surface of a basal plane pyrolytic graphite (bppg) electrode modified with multiwall carbon nanotube. First, the bppg electrode is subjected to abrasive immobilization of carbon nanotubes by gently rubbing the electrode surface on a filter paper supporting the carbon nanotubes. Second, the electrode surface is covered with a thin film of a sol-gel composite containing encapsulated glucose oxidase. The carbon nanotubes offer excellent electrocatalytic activity toward reduction and oxidation of hydrogen peroxide liberated in the enzymatic reaction between glucose oxidase and glucose, enabling sensitive determination of glucose. The amperometric detection of glucose is carried out at 0.3 V (vs saturated calomel electrode) in 0.05 M phosphate buffer solution (pH 7.4) with linear response range of 0.2-20 mM glucose, sensitivity of 196 nA/mM, and detection limit of 50 microM (S/N=3). The response time of the electrode is < 5s when it is stored dried at 4 degrees C, the sensor showed almost no change in the analytical performance after operation for 3 weeks. The present carbon nanotube sol-gel biocomposite glucose oxidase sensor showed excellent properties for the sensitive determination of glucose with good reproducibility, remarkable stability, and rapid response and in comparison to bulk modified composite biosensors the amounts of enzyme and carbon nanotube needed for electrode fabrication are dramatically decreased.  相似文献   

4.
A series of surfactant peptides were created to evaluate the affinity of aromatic AAs for single-walled carbon nanotubes in the absence of complications from peptide folding or self-association. Each surfactant peptide has a lipidlike architecture, with two Lys residues at the C-terminus as a hydrophilic head, five Val residues to form a hydrophobic tail, and the testing AA at the N-terminus. Raman and CD spectroscopic studies reveal that the surfactant peptides have a large unordered structural component which is independent of peptide concentration, suggesting that the peptides undergo minimal association under experimental conditions, thus removing this interference from interpretation of the peptide/carbon nanotube interactions. A lack of peptide self-association is also indicated by sedimentation equilibrium ultracentrifugation results. Optical spectroscopy of the peptide/carbon nanotube dispersions indicate that among the three aromatic AAs, tryptophan has the highest affinity for carbon nanotubes (both bundled and individual states) when incorporated into a surfactant peptide, while the Tyr-containing peptide is more selective for individual carbon nanotubes. Phe has the lowest overall affinity for carbon nanotubes. Raman spectra of dispersions made with SPF, SPY and SPW display similar types of nanotubes dispersed, although differences in the relative nanotube populations are observed by optical spectroscopy.  相似文献   

5.
Due to their unique physicochemical properties, doped carbon nanotubes are now extremely attractive and important nanomaterials in bioanalytical applications. In this work, selecting glucose oxidase (GOD) as a model enzyme, we investigated the direct electrochemistry of GOD based on the B-doped carbon nanotubes/glassy carbon (BCNTs/GC) electrode with cyclic voltammetry. A pair of well-defined, quasi-reversible redox peaks of the immobilized GOD was observed at the BCNTs based enzyme electrode in 0.1M phosphate buffer solution (pH 6.98) by direct electron transfer between the protein and the electrode. As a new platform in glucose analysis, the new glucose biosensor based on the BCNTs/GC electrode has a sensitivity of 111.57 microA mM(-1)cm(-2), a linear range from 0.05 to 0.3mM and a detection limit of 0.01mM (S/N=3). Furthermore, the BCNTs modified electrode exhibits good stability and excellent anti-interferent ability to the commonly co-existed uric acid and ascorbic acid. These indicate that boron-doped carbon nanotubes are the good candidate material for the direct electrochemistry of the redox-active enzyme and the construction of the related enzyme biosensors.  相似文献   

6.
A novel amperometric biosensor highly selective to L-lactate has been developed using L-lactate-cytochrome c oxidoreductase (flavocytochrome b2) isolated for the first time from thermotolerant methylotrophic yeast Hansenula polymorpha as biorecognition element. Different immobilization methods and low-molecular free-diffusing redox mediators have been tested for optimising the electrochemical communication between the immobilized enzyme and the electrode surface. Moreover, the possibility of direct electron transfer from the reduced form of FCb2 to carbon electrodes has been evaluated. The bioanalytical properties of FCb2-based biosensors, such as signal rise time, dynamic range, dependence of the sensor output on the pH value, the temperature and the storage stability were investigated, and the proposed biosensor demonstrated a very fast response and a high sensitivity and selectivity for L-lactate determination.  相似文献   

7.
We report on a highly ordered array of carbon nanotubes (CNTs) that serves as a universally direct nanoelectrode interface for redox proteins and provides an efficient conduit for electron transfer. The site-selective, covalent docking of the enzyme glucose oxidase (GO(x)) on the CNT tips is found to have a marked effect on enhancing electron transfer properties, as measured by cyclic voltammetry. A unimolecular electron transfer rate of 1500 s(-1) has been measured for this system, a value exceeding the rate of oxygen reduction by glucose oxidase. Furthermore, the redox enzyme-CNT array conjugate can be utilized as a quantitative, substrate-specific biosensor.  相似文献   

8.
Sensitivity of Anthrax protective antigen (PA) detection has been improved by directly immobilizing a PA-specific peptide onto a multi-wall carbon nanotube (MWCNT). The MWCNT was covalently immobilized onto a polyaniline (PANI) electrode, which was prepared via electropolymerization of the aniline monomer onto a glassy carbon electrode (GCE). Then, the PA-specific peptide was covalently immobilized to the MWCNT layer for measurement. When comparing this technique to that of PA immobilization on an insulting self assembled organic layer, the advantages of the MWCNT are clear. The MWCNT sensor resulted in enhanced electron transfer across the sensing layer. The resulting limit of detection (LOD) was 0.4 pM, a 13-fold improvement over that of our previous self-assembled organic layer was used for immobilization of the same peptide. Neither positive nor negative interferences were observed when a sample containing both 100 pM PA and bovine serum albumin (BSA) was measured, indicating good selectivity of the proposed sensor.  相似文献   

9.
Li G  Liao JM  Hu GQ  Ma NZ  Wu PJ 《Biosensors & bioelectronics》2005,20(10):2140-2144
A carbon nanotube modified biosensor for monitoring total cholesterol in blood was studied. This sensor consists of a carbon working electrode and a reference electrode screen-printed on a polycarbonate substrate. Cholesterol esterase, cholesterol oxidase, peroxidase and potassium ferrocyanide were immobilized on the screen-printed carbon electrodes. Multi-walled carbon nanotubes (MWCN) were added to prompt electron transfer. Experimental results show that the carbon nanotube modified biosensor offers a reliable calibration profile and stable electrochemical properties.  相似文献   

10.
A molecular assembly consisting of a redox enzyme, NADH peroxidase, a metallized double-helical peptide, and a gold nanoparticle immobilized onto a gold wire derivatized with a benzenedithiol compound, initiated and conducted redox signals in the presence of H(2)O(2) and NADH. The current generated by the binding of NADH, the electron donor, was transduced through the molecular assembly with apparently little loss of signal to the solution. The currents measured correlate to an electron transfer rate constant on the order of 3,000 s(-1) within each assembly. This electron transfer rate is two orders of magnitude higher than the endogenous electron transfer rate from NADH to the native enzyme, 27 s(-1). This rate indicates that the metallized peptide is in a conformation conducive for electron transfer and, in conjunction with the redox enzyme, can form effective conduits of electrical signals. This work demonstrates the feasibility of utilizing designed and highly efficient biomolecular assemblies for the production of ultra-sensitive, in-situ biosensors.  相似文献   

11.
R A Copeland  P A Smith  S I Chan 《Biochemistry》1987,26(23):7311-7316
When cytochrome c oxidase is reduced, it undergoes a conformational change that shifts its tryptophan fluorescence maximum from 329 to 345 nm. Studies of ligand-bound, mixed-valence forms of the enzyme show that this conformational change is dependent on the redox state of the low-potential metal centers, cytochrome a and CuA. The intrinsic fluorescence of oxidized cytochrome c oxidase is not effectively quenched by Cs+; however, marked quenching is observed for the reduced enzyme with a Stern-Volmer constant of 0.69. These observations, together with the significant red shift of the emission maximum, suggest that the emitting tryptophan residues are becoming more solvent accessible in the reduced enzyme. Stopped-flow spectra show that this conformational transition occurs rapidly upon reduction of the low-potential sites with a pseudo-first-order rate constant of 4.07 +/- 0.40 s-1. The conformational change monitored by tryptophan fluorescence is suggested to be related to the previously proposed "open-closed" transition of cytochrome c oxidase. Reductive titration of the cyanide-inhibited enzyme with ferrocytochrome c shows a nonlinear response of the fluorescence shift to added electron equivalents. A theoretical treatment of the reduction of the two interacting sites of the cyanide-inhibited enzyme has been developed that gives the population of each redox state as a function of the total number of electrons accepted by the enzyme. This treatment depends on two parameters: the difference in redox potential between the two metals and the redox interaction between the redox centers.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

12.
An electrochemical sensor for simultaneous quantification of serotonin (5-hydroxytryptamine, 5-HT) and dopamine (DA) using a β-cyclodextrin/poly(N-acetylaniline)/carbon nanotube composite modified carbon paste electrode has been developed. Synergistic effect of multi-walled carbon nanotube (MWCNT) in addition to the pre-concentrating effect of β-cyclodextrin (β-CD) as well as its different inclusion complex stability with 5-HT and DA was used to construct an electrochemical sensor for quantification of these important neurotransmitters. The overlapping anodic peaks of 5-HT and DA at 428 mV on bare electrode resolved in two well-defined voltammetric peaks at 202 and 363 mV vs. Ag/AgCl respectively. The oxidation mechanism of 5-HT and DA on the surface of the electrode was investigated by cyclic voltammetry and it was found that the electrode processes are pH dependent and electrochemical oxidation of 5-HT is totally irreversible while the electrode gave a more reversible process to DA. Under optimized conditions, linear calibration curves were obtained in the range of about 4-200 μM with a detection limits down to sub-μM levels (S/N=3) after 20-s accumulation, for both. The proposed sensor was shown to be remarkably selective for 5-HT and DA in matrices containing different species including ascorbic acid and uric acid. The suitability of the developed method was tested for the determination of 5-HT and DA in the Randox Synthetic Plasma samples and acceptable recoveries were obtained for a set of spiked samples.  相似文献   

13.
Wu K  Fei J  Hu S 《Analytical biochemistry》2003,318(1):100-106
A chemically modified electrode based on the carbon nanotube film-coated glassy carbon electrode (GCE) is described for the simultaneous determination of dopamine (DA) and serotonin (5-HT). The multiwall carbon nanotube (MWNT) film-coated GCE exhibits a marked enhancement effect on the current response of DA and 5-HT and lowers oxidation overpotentials. The responses of DA and 5-HT merge into a large peak at a bare GCE, but they yield two well-defined oxidation peaks at the MWNT film-coated GCE. The experimental parameters were optimized, and a direct electrochemical method for the simultaneous determination of DA and 5-HT was proposed. The interference of ascorbic acid (AA) was investigated, and the results showed that a large excess of AA did not interfere with the voltammetric responses of DA and 5-HT. The modified electrode has been successfully applied for the assay of 5-HT and DA in human blood serum.  相似文献   

14.
A non-enzymatic glucose sensor of multi-walled carbon nanotube-ruthenium oxide/composite paste electrode (MWCNT-RuO(2)/CPE) was developed. The electrode was characterized by using XRD, SEM, TEM and EIS. Meanwhile, cyclic voltammetry and amperometry were used to check on the performances of the MWCNT-RuO(2)/CPE towards glucose. The proposed electrode has displayed a synergistic effect of RuO(2) and MWCNT on the electrocatalytic oxidation of glucose in 3M NaOH. This was possible via the formation of transitions of two redox pairs, viz. Ru(VI)/Ru(IV) and Ru(VII)/Ru(VI). A linear range of 0.5-50mM glucose and a limit of detection of 33μM glucose (S/N=3) were observed. There was no significant interference observable from the traditional interferences, viz. ascorbic acid and uric acid. Indeed, results so obtained have indicated that the developed MWCNT-RuO(2)/CPE would pave the way for a better future to glucose sensor development as its fabrication was without the use of any enzyme.  相似文献   

15.
The linear sweep voltammetric method is used as a new approach for kinetic determination with enzymes accepting reversible redox couples as cosubstrate. A monolayer of hydrogenase molecules is grafted onto a glassy carbon electrode which is both the support of the enzyme and the detector of the activity. Reduced viologen concentration in the enzyme microenvironment is controlled by the electrode potential. The catalytic current produced by the enzyme allows an easy kinetic constant determination without the classical constraints found in hydrogenase kinetic measurements.  相似文献   

16.
A novel biosensor architecture, which is based on the combination of a manual and a non-manual deposition technique for sensor components on the electrode surface is reported. A water-soluble Os-poly(vinyl-imidazole) redox hydrogel is deposited on a graphite electrode by drop-coating (i.e. manually) followed by the electrochemically-induced deposition of an enzyme-containing non-conducting polymer film. The local polymer deposition is initiated by electrochemical generation of H(3)O(+) exclusively at the electrode surface causing a pH-shift to be established in the diffusion zone around the electrode (i.e. non-manually). This pH-shift leads to the protonation of a dissolved polyanionic polymer which in consequence changes significantly its solubility and is hence precipitating on the electrode surface. In the presence of a suitable enzyme, such as quinohemoprotein alcohol dehydrogenase (QH-ADH), the polymer precipitation leads to an entrapment of the redox enzyme within the polymer film. Simultaneously, the water-soluble Os-poly(vinyl-imidazole) redox hydrogel, which is slowly dissolving from the electrode surface after addition of the electrolyte, is co-entrapped within the precipitating polymer layer. This provides the pre-requisite for an efficient electron-transfer pathway from the redox enzyme via the polymer-bound redox centres to the electrode surface. The sensor preparation protocol has been optimised aiming on a high mediator concentration in the polymer film and an effective electron transfer.  相似文献   

17.
Sensors for the determination of L-lysine in samples of fermentation broth have been developed. Low-cost screen-printed sensors comprising a platinum working electrode, an Ag/AgCl pseudo reference and a carbon counter electrode were used as transducers for the enzyme sensors. L-lysine-(alpha)-oxidase from Trichoderma viride has been immobilized by entrapment into a polyurethane hydrogel. Sensors were characterized for L-lysine with respect to pH value, linear range, reproducibility, repeatability, storage and working stability. The sensitivities to other amino acids were also determined. A batch system with two working electrodes, one with immobilized enzyme and one without was adapted for the determination of L-lysine by differential measurements. Good agreement was found between L-lysine concentrations measured by the enzyme sensors and by a conventional amino acid analyzer.  相似文献   

18.
A facile strategy to deposit Pt nanoparticles with various metal‐loading densities on vertically aligned carbon nanotube (ACNT) arrays as electrocatalysts for proton exchange membrane (PEM) fuel cells is described. The deposition is achieved by electrostatic adsorption of the Pt precursor on the positively charged polyelectrolyte functionalized ACNT arrays and subsequent reduction by L ‐ascorbic acid. The application of the aligned electrocatalysts in fuel cells is realized by transferring from a quartz substrate to nafion membrane using a hot‐press procedure to fabricate the membrane electrode assembly (MEA). It is shown that the MEA with vertically aligned structured electrocatalysts provides better Pt utilization than that with Pt on conventional carbon nanotubes or carbon black, resulting in higher fuel cell performance.  相似文献   

19.
An amperometric lactate biosensor was developed based on a conducting polymer, poly-5,2′-5′,2′′-terthiophene-3′-carboxylic acid (pTTCA), and multiwall carbon nanotube (MWNT) composite on a gold electrode. Lactate dehydrogenase (LDH) and the oxidized form of nicotinamide adenine dinucleotide (NAD+) were subsequently immobilized onto the pTTCA/MWNT composite film. The modified electrode was characterized by quartz crystal microbalance (QCM), scanning electron microscopy (SEM), and electrochemical experiments. The detection signal was amplified by the pTTCA/MWNT assembly onto which a sufficient amount of enzyme was immobilized and stabilized by the covalent bond formation between the amine groups of enzyme and the carboxylic acid groups of the pTTCA/MWNT film. Experimental parameters affecting the sensor responses, such as applied potential, pH, and temperature, were assessed and optimized. Analytical performances and dynamic ranges of the sensor were determined, and the results showed that the sensitivity, stability, and reproducibility of the sensor improved significantly using pTTCA/MWNT composite film. The calibration plot was linear (r2 = 0.9995) over the range of 5 to 90 μM. The sensitivity was approximately 0.0106 μA/μM, with a detection limit of 1 μM, based on a signal/noise ratio of 3. The applicability of the sensor for the analysis of l-lactate concentration in commercial milk and human serum samples was demonstrated successfully.  相似文献   

20.
This study demonstrated that redox hydrogel-modified carbon nanotube (CNT) electrodes can be developed as an amperometric sensor that are sensitive, specific and fast and do not require auxiliary enzymes. A redox polymer, poly(vinylimidazole) complexed with Os(4,4'-dimethylbpy)(2)Cl (PVI-dmeOs) was electrodeposited on Ta-supported multi-walled CNTs. The resulted PVI-dmeOs thin film did not change the surface morphology of the CNTs, but turned the CNT surface from hydrophobic to hydrophilic, as studied by scanning electron microscopy (SEM) and static water contact angle measurements. Cyclic voltammetry measurements in a Fe(CN)(6)(3-) solution and electrochemical impedance measurements in an equimolar Fe(CN)(6)(3-/4-) solution demonstrated that the PVI-dmeOs hydrogel thin film was electronic conductive with a resistance of about 15Omega. The PVI-dmeOs/CNT electrodes sensed rapidly, sensitively and specifically to model redox enzymes (glucose oxidase (GOD) and lactate oxidase (LOD)) in amperometric experiments in electrolyte solutions containing the substrates of the measured redox enzymes. Both the CNT substrate and the thin PVI-dmeOs film enhanced the sensing sensitivities. Exploration of the mechanisms suggests that the PVI-dmeOs film may enhance the sensing sensitivities by wiring the enzyme molecules through the redox centers tethered on the mobile redox polymer backbones to the CNT electrodes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号