首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Rauh M  Gröschl M  Rascher W  Dörr HG 《Steroids》2006,71(6):450-458
Plasma 17 alpha-hydroxyprogesterone (17-OHP), androstenedione and testosterone measurements are important for the diagnosis and monitoring of hyperandrogenic disorders, most importantly for congenital adrenal hyperplasia (CAH) due to 21-hydroxylase deficiency. The reliability of immunoassays has proved questionable especially for newborns and children. In order to reduce the analytical interferences due to cross-reactivity or matrix effects, to improve accuracy and shorten the analysis time, we have developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method with atmospheric pressure chemical ionization (APCI) for simultaneous measurement. An on-line extraction cartridge with column-switching technique and liquid chromatography over a Chromolith RP 18 e column allow a rapid and easy quantification. The lowest limit of detection was 0.03-0.06 microg/L. Our method has proved linear up to 250 microg/L (r=0.999). Recoveries (S.D.) of 17-OHP, androstenedione and testosterone in plasma were 100% (5), 102% (2) and 92% (4), respectively. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for 17-OHP (excluding neonate samples) was y=1.942 x+0.255 nmol/L (r=0.695; n=97). In comparison to our values, the immunoassay generally overestimates steroid concentration. The regression equation for the LC-MS/MS (x) and immunoassay (y) methods for testosterone was y=0.963 x+0.035 nmol/L (r=0.955; n=107). Preliminary reference intervals for children were determined as a function of age and sex. The sensitivity and specificity of the LC-MS/MS method offer advantages over routine immunoassays due to the elimination of interferences especially for newborns, high throughput and short chromatographic run time.  相似文献   

2.
A methodology has been developed and validated for the simultaneous quantitation of O6-methyl- and 7-methylguanine in DNA isolated from in vitro exposure to the model alkylating agents: N-methyl-N-nitrosourea (MNU) and methyl methane sulfonate (MMS). After exposure, DNA was isolated and directly hydrolyzed under acid conditions to hydrolytes containing DNA bases (modified and unmodified). The hydrolytes were used for direct O6- and 7-methylguanine quantitation using a rapid and selective liquid chromatography-electrospray tandem mass spectrometry (LC/ESI-MS/MS). The lower limits of quantitation for O6-methyl- and 7-methylguanine were 75.8 and 151.5 fmol, respectively. Linearity of the calibration curve was greater than 0.999 from 75.8 to 151,600.0 fmol for O6-methylguanine and 0.999 from 151.5 to 303,200.0 fmol for 7-methylguanine. The intra-day assay precision relative standard deviation (R.S.D.) values for O6-methylguanine for quality control (QC) samples were < or =9.2% with accuracy values ranging from 90.8 to 118%, and for 7-methylguanine the R.S.D. values for QC samples were < or =11%, with accuracy values ranging from 92.9 to 119%. The inter-day assay precision (R.S.D.) values for O6-methylguanine QC samples were < or =7.9% with accuracy values ranging from 94.5 to 116%, and for 7-methylguanine QC samples were < or =7.1% with accuracy values ranging from 95.2 to 110.2%. This method was used for simultaneous determination of the levels of 7-methyl- and O6-methylguanine in DNA acidic hydrolytes present in a series of incubations from salmon testis DNA treated with either MNU or MMS.  相似文献   

3.
Helicid is a traditional Chinese medicine used to treat headache and insomnia with definite effects. To facilitate pharmacokinetic studies of helicid in man, a sensitive and specific LC-MS/MS method for the quantitative detection of helicid in human plasma was developed and validated. The method involved the addition of bergeninum as the internal standard (IS), protein precipitation, HPLC separation, and quantification by MS/MS system using negative electrospray ionization in the multiple reaction monitoring mode (MRM). The precursor→product ion transitions were monitored at m/z 282.8→120.9 for helicid and m/z 326.9→192.2 for the IS, respectively. The lower limit of quantification (LLOQ) was 0.2 μg/L. The calibration curves for helicid was linear over a concentration range of 0.2-20 μg/L. The intra- and inter-batch analyses of QC samples at 0.4, 2, 20 μg/L indicated good precision (%R.S.D. between 2.69 and 5.47%) and accuracy (between 96.15 and 105.05%). The helicid was stable in human plasma stored at room temperature for at least 24h, 4°C for at least 24h, -20°C for at least 1 month, and for routine three freeze-thaw cycles. This accurate and specific assay provides a useful method for evaluating the pharmacokinetic profile of helicid in humans.  相似文献   

4.
This paper describes a rapid and sensitive analytical method for the quantitation of iptakalim, a novel antihypertensive drug, in human plasma. The method is based on liquid chromatography-tandem mass spectrometry (LC-MS/MS) using sildenafil as internal standard. Sample preparation involved liquid-liquid extraction with dichloromethane-diethyl ether (2:3, v/v) in a basic environment. Chromatography was carried out on an amino column with a mobile phase consisting of acetonitrile-water (55:45, v/v, water containing 0.5% formic acid). Detection employed electrospray ionization (ESI) tandem mass spectrometry in the multiple-reaction-monitoring (MRM) mode. The assay was linear in the concentration range of 0.5-100 ng/ml with a lower limit of quantitation (LLOQ) of 0.5 ng/ml. Intra- and inter-day precision (R.S.D.) were <4.5% and <12.0%, respectively and the accuracy (R.E.) was in the range +/-5%. The method was successfully applied to a single oral dose pharmacokinetic study in human volunteers.  相似文献   

5.
Bioanalytical methods using liquid/liquid extraction (LLE) and liquid chromatography with electrospray tandem mass spectrometry (LC-MS/MS) are widely used. The organic extracts need to be evaporated and reconstituted, hampering further improvement of throughput and automation. In this study, we demonstrated a novel approach of eliminating these two steps in 96-well LLE by using hydrophilic interaction chromatography with MS/MS (HILIC-MS/MS) on silica column with high organic/low aqueous mobile phase. Omeprazole, its metabolite 5-OH omeprazole, and internal standard desoxyomeprazole, were extracted from 0.05 ml of human plasma using 0.5 ml of ethyl acetate in a 96-well plate. A portion (0.1 ml) of the ethyl acetate extract was diluted with 0.4 ml of acetonitrile and 10 microl was injected onto a Betasil silica column (50 mm x 3.0 mm, 5 microm) and detected by API 3000 and 4000 with (+) ESI. Mobile phase with linear gradient elution consists of acetonitrile, water, and formic acid (from 95:5:0.1 to 73.5:26.5:0.1 in 2 min). The flow rate was 1.5 ml/min with total run time of 2.75 min. The method was validated for a low limit of quantitation at 2.5 ng/ml for both analytes. The method was also validated for specificity, reproducibility, stability and recovery. Lack of adverse matrix effect and carry-over was also demonstrated. The inter-day precision and accuracy of the quality control samples at low, medium and high concentration levels were <4.4% relative standard deviation (R.S.D.) and 4.1% relative error (R.E.) for omeprazole, and 4.5% R.S.D. and 5.6% R.E. for 5-OH omeprazole, respectively.  相似文献   

6.
OBJECTIVE: To develop a routine method for quantitative measurement of the folate catabolites p-aminobenzoylglutamate (pABG) and acetamidobenzoylglutamate (apABG) in serum and urine using liquid chromatography-tandem mass spectrometry (LC-MS/MS). DESIGN AND METHODS: Urine, serum and aqueous standards were thawed. Two microliters of d3-glutamic acid (d3-Glu; 1 mmol/L) was added to 200 uL of specimen as internal standard. The samples were acidified with 4 uL 6N HCL, and aliquots were precipitated with 2 volumes (412 uL) of acetonitrile. For urine specimens 30 volumes (6.18 mL) of acetonitrile was used. Samples were centrifuged at 1900 x g for 10 min and the supernatant (10 microL) injected into a Biorad CAT/MET analytical column fitted to the LC-MS/MS. Detection of the catabolites was by selective multiple ion monitoring (multiple SRM) of the respective transitions. Urine and serum samples were analysed in a group of healthy volunteers and in anonymous samples from patients being tested for PTH and urinary catecholamines. RESULTS: pABG and apABG eluted at 5.2 and 4.74 min, respectively while the d3-glutamic acid eluted at around 7 min. Limit of quantitation (LOQ) for both catabolites was 10 nmol/L (which is equivalent to 33.3 fmol for a 10 microL injection). Limit of detection (LOD) was 1 nmol/L based on a signal to noise ratio of 5:1. A linear calibration curve was obtained from 10 to 100 nmol/L for serum specimens and from 10 to 200 micromol/L for urines. Imprecision for spiked serum samples (n=10) was between 2.5 and 20% for apABG and 4.5 and 21% for pABG (at 10 and 100 nmol/L, respectively). Imprecision for spiked urine samples (n=10) was between 2.9 and 4.0% for apABG and 6.0-12.7% for pABG. Recoveries were between 80 and 122% for serum samples and between 92 and 102% for urine specimens. Total folate catabolites in random urine samples from volunteers (n=5) are 2.9+/-2.3 umol/L (mean+/-S.D.). This group also had total serum catabolites of 11.9+/-7.6 nmol/L and serum folate of 35.3+/-5.8 nmol/L. Serum from patients being tested for PTH (n=11) had serum folate levels of 27.0+/-10.4 nmol/L with total serum catabolites of 20.4+/-23.8 nmol/L. Levels of serum folate and total catabolites in pregnant women (n=18) were 33.9+/-22.7 and 11.4+/-8.7 nmol/L, respectively. Mean urinary folate catabolites in patients being tested for urinary catecholamines (n=19) was 581.8+/-368.4 nmol/L. CONCLUSION: A simple, reliable and highly specific method by LC-MS/MS for detecting and quantifying the folate catabolites pABG and apABG was developed. This enables, for the first time, the routine clinical analysis of folate utilization in patients.  相似文献   

7.
A sensitive and selective liquid chromatography-tandem spectrometry method for the determination of zolmitriptan was developed and validated over the linearity range 0.05-30 ng/ml with 0.5 ml of plasma using diphenhydramine as the internal standard. Liquid-liquid extraction using a mixture of diethyl ether and dichloromethane was used to extract the drug and the internal standard from plasma. The mass spectrometer was operated under the selected reaction monitoring (SRM) mode using the atmospheric pressure chemical ionization (APCI) technique. The instrument parameters were optimized to obtain 3.0 min run time. The mobile phase consisted of acetonitrile-water-formic acid (70:30:0.5), at a flow rate of 0.5 ml/min. In positive mode, zolmitriptan produced a protonated precursor ion at m/z 288 and a corresponding product ion at m/z 58. And internal standard produced a protonated precursor ion at m/z 256 and a corresponding product ion at m/z 167. The inter- and intra-day precision (%R.S.D.) were less than 8.5% and accuracy (%error) was less than -2.5%. The method had a lower limit of quantification of 0.05 ng/ml for zolmitriptan, which offered increased sensitivity and selectivity of analysis, compared with existing methods. The method was successfully applied to a pharmacokinetic study of zolmitriptan after an oral administration of 5 mg zolmitriptan to 20 healthy volunteers.  相似文献   

8.
Deltamethrin (DLM), [(S)-alpha-cyano-d-phenoxybenzyl-(1R,3R)-e-(2,2 dibromovinyl)-2,2-dimethylcyclo-propane-1-carboxylate], is a pyrethroid insecticide widely used in agriculture and households. There are several methods for analysis of DLM in biological fluids and tissues, but these methods are time consuming. They generally involve the extraction of DLM with lipid-soluble solvents such as n-pentane, n-hexane, diethylether or acetone, and subsequent evaporation of the solvent. A more rapid and sensitive high-performance liquid chromatography (HPLC) method to analyze DLM in plasma and tissues (liver, kidney, and brain) was developed and validated according to U.S. Food and Drug Administration (U.S. FDA) and International Conference on Harmonization (ICH) of Technical Requirements for Registration of Pharmaceuticals for Human Use guidelines. The limit of detection (S/N of 3/1) for DLM was 0.01 microg/ml for plasma, liver, kidney and brain. The method performances were shown to be selective for DLM and linear over the concentration range 0.01-20.0 microg/ml. For five replications of samples at 0.05, 0.1, 0.2, 1.5 and 4.0 microg/ml, intraday precision and accuracy values were in the range of 0.7-13.1% relative standard deviation (%R.S.D.) and 1.8-14.1%Error, respectively. Interday (n = 15) precision and accuracy values at 0.05, 0.1, 0.2, 1.5, and 4.0 microg/ml were in the range of 3.2-15.2% (%R.S.D.) and 3.7-14.8%Error, respectively. The absolute recoveries of DLM ranged from 93 to 103% for plasma, 95 to 114% for liver, 97 to 108% for kidney, and 95 to 108% for brain. This method can be quite useful for DLM pharmacokinetic and tissue distribution studies, for which multiple plasma and tissue samples have to be analyzed quickly with high reproducibility.  相似文献   

9.
In samples where the amount of DNA is limited, the polymerase chain reaction (PCR) can amplify specific regions of the DNA. A quantitative analysis of the PCR product would be desirable to ensure sufficient DNA is available for analysis. In this study, we examine the use of capillary electrophoresis (CE) with laser fluorescence detection for quantitation of PCR products. A coated open tubular capillary was used with a non-gel sieving buffer and a fluorescent intercalating dye to obtain results within 20 minutes. Using an internal standard, peak migration time was below 0.1% relative standard deviation (R.S.D.) with a peak area precision of 3% R.S.D. In comparison to quantitation by hybridization, (i.e., slot blot) and spectrophotometric analysis, capillary electrophoresis shows distinct advantages due to its ability to separate unincorporated primers and PCR byproducts from the targeted PCR product. The results demonstrate that CE can be used to monitor the quality and quantity of the PCR product.  相似文献   

10.
Wudy SA  Hartmann M  Homoki J 《Steroids》2002,67(10):851-857
A first assay based on stable isotope dilution/gas chromatography-mass spectrometry (ID/GC-MS) has been developed for plasma 11-deoxycortisol (Reichstein's compound S), the leading hormonal marker of 11beta-hydroxylase deficiency. A suitable internal standard being unavailable, we synthesized dideuterated 11-deoxycortisol according to a newly devised synthetic procedure. 17,21-Dihydroxy-pregna-1,4-diene-3,20-dione underwent selective deuteration using Wilkinson's catalyst. Our product [1alpha,2alpha-2H2]11-deoxycortisol was obtained in good yield (35.6%) and high isotopic purity (0.1% 2H0, 99.9% 2H2). Structural confirmation was done by MS and NMR. Our plasma work up consisted of equilibration of plasma with internal standard ([1alpha,2alpha-2H2]11-deoxycortisol), solid phase extraction with Extrelut NT columns, a clean up step using Sephadex LH-20 mini columns and preparation of heptafluorobutyrates as derivatives. Quantification was achieved by selected ion monitoring of m/z 465.40 (analyte) and m/z 467.40 (internal standard). One hundred twenty picograms of 11-deoxycortisol gave a signal to noise ratio of 10. Calibration plot was linear. Spiking experiments showed good accuracy with relative errors <3.0%. Intraassay precision CV was 4.78% and interassay precision CV was 4.56%. We succeeded in integrating our new analyte into our already existing multisteroid ID/GC-MS plasma assay, which now, in its expanded version, is capable of determining all major diagnostic steroids of androgen related disorders in a single profile: 11-deoxycortisol, 17alpha-hydroxyprogesterone, testosterone, 4-androstenedione, 17alpha-hydroxypregnenolone, dehydroepiandrosterone, androstanediol and 5alpha-dihydrotestosterone. The diagnostic potential of our multisteroid ID/GC-MS assay, the small amounts of plasma (0.5 ml) required, the rapid and convenient sample work up, the application of benchtop GC-MS instrumentation, and highest specificity offered by mass spectrometric detection prove our assay suitable for routine clinical use, especially in pediatric endocrinology.  相似文献   

11.
A one-step simple and rapid high performance liquid chromatography (HPLC) method was developed for the determination of oxytetracycline (OTC) in fish tissue. The method involves liquid extraction of muscle tissue, precipitation of proteins and reversed phase HPLC analysis with spectrophotometric detection. The limit of quantitation of OTC in spiked fish muscle was 0.04 microg/g and the method showed high linearity (r(2) = >0.999) in the working range of 0.04-2 microg/g. The precision (%R.S.D.) was between 1.9 and 7.5% for the concentration range 0.04-1.0 microg/g and there was no significant difference between the concentrations determined on three different test days for all four spiked concentrations. The percentage recovery over the spiked concentration range 0.04-1.0 microg/g was consistently within a narrow range of 33-35%. While the method had the advantage of high precision, sensitivity and linearity, the method's additional salient advantages included high sample through-put (60 individual preparations per day) and minimum amount of consumables, time and labour required to perform the analysis. The method was successfully applied to a pharmacokinetic study.  相似文献   

12.
A sensitive method was developed and validated for the measurement of 17-(allylamino)-17-demethoxygeldanamycin (17AAG) and its active metabolite 17-amino-17-demethoxygeldanamycin (17AG) in human plasma using 17-(dimethylaminoethylamino)-17-demethoxygeldanamycin (17DMAG) as an internal standard. After the addition of internal standard, 200 microL of plasma was extracted using ice cold acetonitrile followed by analysis on a Thermo Finnigan triple-quadruple mass spectrometer coupled to an Agilent 1100 HPLC system. Chromatography was carried out on a 50 mm x 2.1 mm Agilent Zorbax SB-phenyl 5 microm column coupled to a 3mm Varian metaguard diphenyl pre-column using glacial acetic acid 0.1% and a gradient of acetonitrile and water at a flow rate of 500 microL/min. Atmospheric pressure chemical ionization and detection of 17AAG, 17AG and 17DMAG were accomplished using selected reaction monitoring of m/z 584.3>541.3, 544.2>501.2, and 615.3>572.3, respectively in negative ion mode. Retention times for 17AAG, 17AG, and 17DMAG were 4.1, 3.5, and 2.9 min, respectively, with a total run time of 7 min. The assay was linear over the range 0.5-3000 ng/mL for 17AAG and 17AG. Replicate sample analysis indicated within- and between-run accuracy and precision within 15%. The recovery of 17AAG and 17AG from 200 microL of plasma containing 1, 25, 300, and 2500 ng/mL was 93% or greater. This high-performance liquid chromatographic tandem mass spectroscopy (HPLC/MS/MS) method is superior to previous methods. It is the first analytical method reported to date for the quantitation of both 17AAG and its metabolite 17AG and can reliably quantitate concentrations of both compounds as low as 0.5 ng/mL.  相似文献   

13.
A previously reported enantioselective LC-MS assay for the determination of (R)- and (S)-methadone [Met] and (R)- and (S)-2-ethylidene-1,5-dimethyl-3,3-diphenyl-pyrrolidine [EDDP] (the primary metabolite of Met) has been adapted for use in the simultaneous determination of the plasma concentrations of Met, EDDP, buprenorphine (Bu) and norbuprenorphine (norBu). All of the target compounds were separated within 15 min using an alpha1-acid glycoprotein chiral stationary phase, a mobile phase composed of acetonitrile: ammonium acetate buffer [10 mM, pH 7.0] in a ratio of 18:82 (v/v), a flow rate of 0.9 ml/min at 25 degrees C. Deuterium labeled compounds were used as internal standards [d4-Bu, d3-norBu, (R,S)-d3-Met and (R,S)-d3-EDDP] and linear relationships between peak height ratios and drug concentrations were obtained for Bu and norBu in the range 0.2-12 ng/ml with correlation coefficients greater than 0.999. The relative standard deviations (%R.S.D.) for the intra- and inter-day precision of the method were <4.5% and for accuracy was <4.0%. The method was validated and used to analyze plasma samples obtained from opioid dependent methadone-maintained adults enrolled in a research study.  相似文献   

14.
BackgroundThe accurate measurement of 25-hydoxy vitamin D (25OH-D) in serum has been a challenge for many years. We developed a liquid chromatography tandem mass spectrometry (LC Tandem MS) assay for the quantitative determination of 25OH-D2 and 25OH-D3 in serum. The new method was compared with two widely used commercially available immunoassays.MethodsSample preparation involved protein precipitation with acetonitrile containing deuterated forms of the target species as internal standards. An API 5000 mass spectrometer coupled with a photoionization source was used for quantitation. The performance of the new LC Tandem MS assay was compared with a radioimmunoassay (RIA, Diasorin) and a chemiluminescence immunoassay (ECLIA, Roche Diagnostics), analysing serum obtained from 152 individuals.ResultsUsing 100 μl of serum, the LC Tandem MS assay had a limit of quantitation of 1.3 nmol/L for both 25OH-D2 and 25OH-D3 with a linear response between 1.3 and 625 nmol/L and accuracy of between 95 and 124%. Intra- and inter-assay precision were ≤7% and ≤4%, respectively. Measurement of 25OH-D levels in 152 serum samples gave run averages of 71, 56 and 62 nmol/L for LC Tandem MS, ECLIA and RIA, respectively. Correlations between the various methods were: LC Tandem MS vs. RIA: r = 0.931; LC Tandem MS vs. ECLIA: r = 0.784; RIA vs. ECLIA: r = 0.787. The LC Tandem MS method had a positive proportional bias of 26% over the RIA, whereas the ECLIA showed variable differences.ConclusionThe new LC Tandem MS assay is accurate and precise at physiologically relevant 25OH-D concentrations, and compares favourably with the RIA. In contrast, the ECLIA shows variable bias with the other assays tested.  相似文献   

15.
Mexiletine is an antiarrhythmic agent used in the treatment of ventricular arrhythmia. The drug has a narrow therapeutic window which necessitates monitoring its serum concentrations. We describe a gas chromatographic–mass spectrometric analysis of mexiletine using selected ion monitoring. Mexiletine was extracted from alkaline serum with dichloromethane and then derivatized with perfluorooctanoyl chloride. The derivatization reaction was completed in 20 min at 80°C. We used N-propylamphetamine as the internal standard. The ions monitored were m/z 122, 454 and 575 for the derivatized mexiletine and m/z 91, 118, 440 and 452 for the derivatized internal standard. The within-run precision at a serum mexiletine concentration of 1 mg/l was 1.9% (mean=0.98, S.D.=0.019 mg/l, n=7) and the between-run precision was 2.5% (mean=0.99, S.D.=0.025 mg/l, n=7). The assay was linear for serum mexiletine concentrations of 0.2 to 4 mg/l. The detection limit was 0.1 mg/l. The average recoveries of mexiletine and the internal standard were 80% and 84%, respectively at a mexiletine concentration of 1 mg/l. There was no carry over problem in our assay. We observed a good correlation between mexiletine concentrations measured by a reference laboratory (GC) and by our new GC–MS assay.  相似文献   

16.
N-Acetyl-L-glutamate (N-acetylglutamate) content and N-acetylglutamate synthase activity ranges were established in human liver tissue homogenates by stable isotope dilution. The methods employ N-[methyl-2H3]acetyl[15N]glutamate as internal standard, extraction of N-acetylglutamate by anion-exchange technique and its determination by g.l.c.-mass spectrometry by using selected ion monitoring. Hepatic N-acetylglutamate content in 16 different human livers, normal in structure and function, ranged from 6.8 to 59.7 nmol/g wet wt. (25.0 +/- 13.4 mean +/- S.D.) or from 64.6 to 497.6 nmol/g of protein (223.2 +/- 104.2 mean +/- S.D.). In vitro, N-acetylglutamate synthase activity in liver tissue homogenate ranged from 44.5 to 374.5 (132.0 +/- 90.6 mean +/- S.D.) nmol/min per g wet wt. or from 491.7 to 3416.9 (1159.6 +/- 751.1 mean +/- S.D.) nmol/min per g of protein. No correlation was found between hepatic N-acetylglutamate concentrations and the respective maximal enzymic activities in vitro of N-acetylglutamate synthase. The marked variability in this system among individual livers may reflect its regulatory role in ureagenesis.  相似文献   

17.
Blood samples from wild mammals and birds are often limited in volume, allowing researchers to quantify only one or two steroids from a single sample by immunoassays. In addition, wildlife serum or plasma samples are often lipemic, necessitating stringent sample preparation. Here, we validated sample preparation for simultaneous liquid chromatography--tandem mass spectrometry (LC-MS/MS) quantitation of cortisol, corticosterone, 11-deoxycortisol, dehydroepiandrosterone (DHEA), 17β-estradiol, progesterone, 17α-hydroxyprogesterone and testosterone from diverse mammalian (7 species) and avian (5 species) samples. Using 100 μL of serum or plasma, we quantified (signal-to-noise (S/N) ratio ≥ 10) 4-7 steroids depending on the species and sample, without derivatization. Steroids were extracted from serum or plasma using automated solid-phase extraction where samples were loaded onto C18 columns, washed with water and hexane, and then eluted with ethyl acetate. Quantitation by LC-MS/MS was done in positive ion, multiple reaction-monitoring (MRM) mode with an atmospheric pressure chemical ionization (APCI) source and heated nebulizer (500°C). Deuterated steroids served as internal standards and run time was 15 minutes. Extraction recoveries were 87-101% for the 8 analytes, and all intra- and inter-run CVs were ≤ 8.25%. This quantitation method yields good recoveries with variable lipid-content samples, avoids antibody cross-reactivity issues, and delivers results for multiple steroids. Thus, this method can enrich datasets by providing simultaneous quantitation of multiple steroids, and allow researchers to reimagine the hypotheses that could be tested with their volume-limited, lipemic, wildlife samples.  相似文献   

18.
A sensitive and accurate stable isotope dilution GC/MS assay was developed and validated for the quantification of succinylacetone (SA) in plasma and amniotic fluid (AF). SA is pathognonomic for tyrosinemia type I, a genetic disorder caused by a reduced activity of fumarylacetoacetate hydrolase (FAH). In untreated patients, SA can easily be measured in plasma and urine because the expected concentrations are in the micromol/L range. Due to a founder effect, the province of Quebec has an unusually high prevalence of tyrosinemia type I, hence, the quantification of SA in AF or plasma of treated patients in the nmol/L range becomes very useful. The method utilizes 13C5-SA as an internal standard and a three-step sample treatment consisting of oximation, solvent extraction and TMCS derivatization. The assay was validated by recording the ion intensities of m/z 620 for SA and m/z 625 for ISTD in order to demonstrate the precision of measurements, the linearity of the method, limit of quantification and detection (LOQ and LOD), specificity, accuracy, as well as metabolite stability. Values for the intra-day assays ranged from 0.2 to 3.2% while values for the inter-day assays ranged from 1.9 to 5.6% confirming that the method has good precision. A calibration plot using SA detected by GC/MS gave excellent linearity with a correlation coefficient of 0.999 over the injected concentration range of 5-2000 nmol/L. LOQ and LOD were 3 and 1 nmol/L, respectively. The usefulness of this method was demonstrated by SA quantification in an AF sample of an affected fetus and in plasma of patients treated with NTBC. The results demonstrate that this novel GC/MS method may be a valuable tool for metabolic evaluation and clinical use.  相似文献   

19.
A sensitive and specific LC-MS/MS method employing positive electrospray ionization for the determination of ARQ 501 (beta-lapachone) in (nu/nu) mouse plasma and tumor tissue is described. Samples were processed using protein precipitation with acetonitrile. A d6 analog of ARQ 501 was used as the internal standard (IS). The analytes were separated using a Zorbax SB8 column (30mmx2.1mm i.d. 5mum particle size) and analyzed in the multiple reaction monitoring (MRM) mode using mass transitions of 243>159 and 249>159m/z for ARQ 501 and d6-ARQ 501, respectively. The lower limit of quantitation (LLOQ) for ARQ 501 was 3.0ng/mL. The calibration curve was linear in the range of 3.0-2000ng/mL with a correlation coefficient better than 0.99. Intra- and inter-batch precisions were within 8.4% for plasma and 11.8% for tumor samples. Accuracy expressed as percentage relative error (%R.E.) ranged from -9.0 to 7.7 for both plasma and tumor samples. Recovery was between 106 and 113% for both ARQ 501 and its d6 analog. Plasma pharmacokinetic data of ARQ 501 in mouse from intraperitoneal (IP) dosing at 60mg/kg obtained using this validated method is presented along with tumor concentration data. The C(max), AUC((0-infinity)), t(1/2), Cl/F, and V(d)/F were determined to be 4016ng/mL, 4392hng/mL, 3.9h, 13.7L/h/kg, and 76.5L/kg, respectively. Tumor tissue concentrations were in the range 1-2muM for approximately 2h post-dose.  相似文献   

20.
This paper reports the development and validation of an improved assay for quantitation of fatty acid ethyl esters (FAEEs) in human meconium using liquid chromatography/tandem mass spectrometry (LC–MS/MS). FAAEs (ethyl laurate, ethyl myristate, ethyl palmitate, ethyl palmitoleate, ethyl stearate, ethyl oleate, ethyl linoleate, ethyl linolenate, and ethyl arachidonate) and the internal standard (I.S.), ethyl heptadecanoate, were separated by reverse phase HPLC and quantified by MS/MS using electrospray ionization (ESI) and multiple reaction monitoring (MRM) in the positive ionization mode. The absolute recovery of FAEEs varied from 55 ± 10% for 0.33 nmol/g (100 ng/g) of ethyl linoleate up to 86 ± 8% for 1.55 nmol/g (500 ng/g) of ethyl miristate. The LODs and LOQs varied from 0.01 to 0.08 nmol/g and from 0.02 to 0.27 nmol/g, respectively. The assay has been successfully applied to examine the FAEE levels in 81 meconium samples from babies born to mothers reporting alcohol consumption, to varying degrees, during pregnancy.  相似文献   