首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An enzyme-linked immunosorbent assay (ELISA) has been developed for the measurement of tetanus antitoxin in human sera as an alternative to the toxin neutralization test in mice, the currently accepted method of assay. The ELISA was found to be simple and quick to perform and required only small amounts of materials. In addition, the assay was found to give reproducible estimates of antitoxin levels and to measure antitoxin at levels as low as 0.01 IU per ml, a sensitivity similar to that of the neutralization test. Furthermore, a comparison of the results of the ELISA and the neutralization test involving 80 human sera, including sera with both high and low antitoxin levels, showed close agreement in antitoxin levels obtained by the two methods. It was concluded that ELISA was an acceptable alternative to the toxin neutralization test in mice for the measurement of tetanus antitoxin levels in human sera.  相似文献   

2.
The usefulness of the toxin binding inhibition test (ToBI) for the titration of tetanus antibody in human sera was assessed. Sera from 80 healthy people with different vaccination histories that had been previously tested by the in vivo toxin neutralization (TN) test were retested by the ToBI test. The lowest tetanus antibody titre which could be detected by using 0.1 Lf/ml tetanus toxin was 0.01 IU/ml. Comparison between the estimates obtained by the ToBI test and those obtained by the TN test (r = 0.93 and r = 0.7 for titration low titre sera) showed good correlation. No overestimation of antibody content was seen in titrating low titre sera by the ToBI test. It is concluded that the ToBI-test is a reliable alternative to toxin neutralization test in mice.  相似文献   

3.
The tetanus antitoxin titres of 174 serum samples from healthy adults were determined by a standardization indirect haemagglutination test (IHA) and the conventional toxin neutralization (TN) test. The serum samples were titrated by the IHA test using glutaraldehyde-fixed and toxoid sensitized sheep erythrocytes before and after the treatment of the sera with 2-mercaptoethanol (2-ME). The IHA method has been found to be very sensitive and specific for the estimation of tetanus antitoxin in human sera. The IHA titres before the treatment of the sera with 2-ME were generally about four times higher than the TN titres and the correlation coefficient between these titres was 0.94. The IHA titres after the treatment of the sera with 2-ME were in good agreement with the TN titres and there was no statistically significant differences between the titres by the two methods. The tetanus antitoxin titres of 50% of the sera were below the minimum protective titres of tetanus antitoxin (0.01 IU/ml). In 19.5% of the sera the antitoxin level (IU/ml) ranged from 0.01 to 0.1, in 20.1% from 0.1 to 1.0 and in 10.4% from 1.0 to 10.0.  相似文献   

4.
The ability of an enzyme-linked immunosorbent assay (ELISA) to detect tetanus antitoxin in human sera has been evaluated in comparison with the in vivo seroneutralization test. The results of this study, carried out on 171 serum samples, show that ELISA is a sensitive and specific in vitro test for immunity to tetanus in man; it reveals the minimum protective level of 0.01 IU/ml and is well correlated with seroneutralization. A comparison has also been made with indirect haemagglutination. Differences in specificity in low titered sera, although not statistically significant, have been observed. Reported data suggest that the ELISA may be used for the estimation of tetanus antitoxin in sero-epidemiological surveys and for clinical purposes with reliability equal--and perhaps superior--to that of IHA.  相似文献   

5.
The methods for determining the level of type A Perfringens antitoxin in human blood sera were examined and compared. The ratios for correlating the data obtained in the toxin neutralization test (NT) in vivo, in the passive hemagglutination test (PHT), and as a result of the enzyme-labeled immunosorbent assay (ELISA) with regard to the antitoxin level measured in the NT in vitro were equal to 0.88, 0.64 and 0.39, respectively. The sensitivity of the NT in vivo and in vitro was 0.25 IU/ml, that of the PHT 0.01-0.005 IU/ml, and that of the ELISA 0.01-0.02 IU/ml Perfringens antitoxin. To perform the NT, not less than 1 ml blood serum is required, while for the PHT and ELISA, 0.1-0.05 ml. Provided hyghly purified anatoxin is used for preparing the erythrocyte diagnosticum Perfringens, and polysterene plates are sensitized in performing the ELISA, all the reactions are specific. While titrating human blood sera containing type A Perfringens antitoxin, use in the PHT may be made of type A Perfringens rabbit antiserum as reference.  相似文献   

6.
The quality of tetanus toxin affected the sensitivity of the toxin neutralization (TN) test greatly. By using purified toxin a minimum level of 0.001 IU/ml of tetanus antitoxin could be detected whereas with crude toxin a level of 0.025 IU/ml only could be detected. The TN test described in this report permitted titration of tetanus antitoxin in twofold dilution steps from levels as low as 0.001 IU/ml using 0.6 ml of serum only at the L+/5000 level of purified tetanus toxin. Treatment of the sera with 2-mercaptoethanol (2-ME) did not affect the TN titres showing that the TN test detects the neutralizing antibodies (IgG) which are not affected by 2-ME. The TN test was found to be a highly sensitive and reproducible test.  相似文献   

7.
Samples from 20 lots of diphtheria-tetanus (adult use dT) vaccine and from 20 lots of diphtheria-tetanus-pertussis (DTP) vaccine were used to standardize and validate the in vitro toxin binding inhibition (ToBI) test for the immunogenicity test of the tetanus component. The levels of tetanus antitoxin obtained by ToBI test were compared to those obtained using the toxin neutralization (TN) test in mice routinely employed to perform the quality control of the tetanus component in adsorbed vaccines. The results ranged from 1.8 to 3.5 IU/ml for dT and 2 to 4 IU/ml for DTP by ToBI test and 1.4 to 3 IU/ml for dT and 1.8 to 3.5 IU/ml for DTP by TN in mice. These results were significantly correlated. From this study, it is concluded that the ToBI test is an alternative to the in vivo neutralization procedure in the immunogenicity test of the tetanus component in adsorbed vaccines. A substantial refinement and a reduction in use of animals can be achieved.  相似文献   

8.
In Brazil, until 2004, the immunization policy against diphtheria involved childhood vaccination with no official routine booster dose administered after 15 years of age. This study assessed functional antibody levels against diphtheria among blood donors. A total of 140 blood samples were collected, and diphtheria antitoxin levels were evaluated by Vero cell neutralization test. The mean age of the population was 34 years old (range: 18-61 years); 37.8% females and 62.2% males. Overall, 30.7% (95%, CI: 23.4-38.7) individuals presented neutralizing antitoxin antibody titers < 0.01 IU/ml; 42.1% (95%, CI: 34.1-50.4) showed values between 0.01-0.09 IU/ml and, 27.1% (95%, CI: 20.2-34.9) had (3) 0.1 IU/ml. In the subgroup of individuals with history of diphtheria immunization during childhood (85%), a number of 28.5% showed unprotective levels of circulating neutralizing antibody (< 0.01 IU/ml). Despite the continuous progress of immunization programs directed to Brazilian population, currently healthy adults remain susceptible to diphtheria.  相似文献   

9.
In the USA, the potency of commercially prepared equine tetanus antitoxin is determined by the method outlined in the Code of Federal Regulations, Title 9, Part 113.451. In the current test, commercial equine tetanus antitoxin is tested by a toxin neutralization test in guinea pigs. The in vivo test measures antitoxin content through effectiveness of protection of guinea pigs injected with diluted mixtures of antitoxin and a standard toxin. A competitive enzyme-linked immunosorbent assay, designed as an in vitro alternative to the in vivo test, measures antitoxin content based on a competitive reaction between standard or unknown serum and murine monoclonal antibody specific for tetanus toxin. The monoclonal antibody used in the assay delayed death in mouse passive protection studies and reacted with the C fragment of tetanus toxin. No cross-reaction was observed when the antibody was tested with the toxins of Clostridium chauvoei, C. novyi, C. perfringens, or C. sordellii. The in vitro test will measure the antitoxin content of serum samples containing 100-1500 units of antitoxin. Tetanus antitoxin titers obtained by the competitive enzyme-linked immunosorbent assay compared favorably with the toxin neutralization test conducted in guinea pigs. The in vitro assay serves as a feasible alternative to the in vivo test because it can be completed in less time, is reproducible, and eliminates the use of test animals.  相似文献   

10.
Immunity to tetanus: tetanus antitoxin and anti-BIIb in human sera   总被引:1,自引:0,他引:1  
Immunity to tetanus was investigated in 157 individuals aged between 1 and 77 years using, for the evaluation of both tetanus antitoxin and antibody to fragment BIIb (anti-BIIb), an easily performed ELISA that gave reproducible results. Among these people 72% were protected against tetanus (tetanus antitoxin titres greater than 0.06 IU ml-1). Anti-BIIb titres greater than 0.15 U ml-1 were found in 75% of the males vs 57% of the females (P less than 0.02) with marked variations according to age. Furthermore, 13 out of 41 individuals with antitoxin titres less than 0.06 IU ml-1 (not protected against tetanus) were found to have anti-BIIb titres greater than 0.15 U ml-1. These data raise questions as to the significance and protective effect of anti-BIIb against tetanus.  相似文献   

11.
The use of indirect ELISA for the quantitation of tetanus toxin neutralizing antibodies in human sera is limited by marked overestimations in low titered sera. The reasons for the discrepancy between the results obtained by ELISA and by in vivo assay and modifications of the ELISA to overcome the problem were investigated. Catching ELISA and indirect ELISA using trays coated with the contaminant proteins in toxoid preparations indicated that antibodies to contaminants were only partly responsible for the discrepancy and the introduction of these modifications did not solve the problem. In ELISA competition experiments with toxin neutralizing monoclonal antibodies, the human immunoglobulins irrelevant in toxin neutralization, but detectable in indirect ELISA, were found to be difficult to inhibit in their binding to the solid antigen phase. These might represent antitoxins bound bivalently to the solid phase but with affinities in monovalent binding insufficient for toxin neutralization or other coupled antibodies due to conformational changes of the antigen. A competition ELISA with toxin in solution was therefore developed to assess selectively the antitoxin capable of binding the antigen in solution and by this approach the in vivo activities of even low titered sera were accurately predicted. This antigen competition ELISA may be easily introduced into routine tetanus serology and the principle may also be of value for the in vitro detection of functional antibodies to other antigens.  相似文献   

12.
制备一种精确的破伤风抗体定量试剂,用于人源破伤风抗体的定量及人群破伤风抗体水平的测定。以人源破伤风免疫球蛋白国家标准品建立定量反应曲线,经系统优化后建立双抗原夹心法定量检测系统。定量反应曲线显示,抗体浓度在10~120m IU/m l之间,相关系数r=0.9993。精密度(CV)≤7%。实际应用验证,未经(TTC)免疫的献血员中,具有保护性抗体水平(0.01 IU/m l)的比例只占12.2%。经3针(TTC)免疫后,抗体水平均大于0.01 IU/m l,经动物体内中和试验法(NT)定量的3批破伤风免疫球蛋白,用制备的酶联免疫破伤风抗体定量试剂测定,其回收率分别为109%、98%和93%。结论,该试剂可用于破伤风抗体的精确定量。  相似文献   

13.
The use of the principle of inhibition of toxin binding to an antitoxin coated immunoassay plate as described in a previous paper for tetanus antitoxin titration, was adapted for the estimation of diphtheria antitoxin in human sera. With a few modifications, a Toxin-Binding Inhibition (ToBI) test was developed which could be used for a combined estimation of both tetanus and diphtheria antitoxin levels. The application of streptavidin-biotinylated peroxidase complex when using small serum samples (less than 50 microliters) is discussed. Antitoxin titres (both diphtheria and tetanus) of 0.002 IU ml-1 were detectable by the ToBI test, this being far below the level considered to be protective in man. Sera from 140 adults with different vaccination histories were titrated for both tetanus and diphtheria antitoxin. Good correlations were found between the estimates obtained by the ToBI test and those obtained by the toxin-neutralization (TN) test in mice (tetanus antitoxin) and those obtained in the in vitro neutralization test in VERO cells (diphtheria antitoxin). It is concluded that the ToBI test is a simple and reliable alternative to the functional models currently in use for the estimation of diphtheria and tetanus antitoxin levels. In addition, the ToBI test eliminates the need for laboratory-animal or cell-culture facilities and can be performed with small quantities of serum as required in field trials.  相似文献   

14.
Grover SS  Negi SS  Singh S  Ray K 《Biologicals》2012,40(4):262-265
The level of circulating tetanus toxin, antitoxin and their individual influence on the outcome of tetanus cases were determined in unimmunized 125 neonatal and 39 infant cases of tetanus. PHA (passive haemagglutination) test showed 40% positive cases for toxin while its absence in the remaining cases indicated of either toxin fixation to the central nervous system (CNS) or it got neutralized by antitoxin. TN (toxin neutralization) and PHA test carried out in 46 sera samples revealed a strong positive correlation (r = 0.9) showing that 35/46 (76%) and 38/46 (82.6%) samples were positive for antitoxin, respectively. 25.4% of the neonate and infant cases and 34% of the control group had a protective serum tetanus antitoxin level. 42.5% of the paired sera from unimmunized mothers and their neonates showing nonprotective antitoxin levels suggested that a high level of antitoxin is needed for transplacental transfer, although transfer may not play a decisive role in the resistance against the disease. The presence of toxin or antitoxin in the clinical cases did not affect the outcome of the disease, although in neonates, presence of toxin was found to be a bad prognostic sign. This study explicitly advocates for the need to improve the vaccination coverage strategy.  相似文献   

15.
A new commercial anti-Japanese encephalitis virus IgM and IgG indirect immunofluorescence test (IIFT) was evaluated for the detection of the humoral immune response after Japanese encephalitis vaccination. The IgM IIFT was compared to two IgM capture ELISAs and the IgG IIFT was analysed in comparison to a plaque reduction neutralization test (PRNT50) and an IgG ELISA. Moreover, the course of the immune reaction after vaccination with an inactivated JEV vaccine was examined. For the present study 300 serum samples from different blood withdrawals from 100 persons vaccinated against Japanese encephalitis were used. For the IgM evaluation, altogether 78 PRNT50 positive samples taken 7 to 56 days after vaccination and 78 PRNT50 negative sera were analyzed with the Euroimmun anti-JEV IgM IIFT, the Panbio Japanese Encephalitis - Dengue IgM Combo ELISA and the InBios JE Detect IgM capture ELISA. For the IgG evaluation, 100 sera taken 56 days after vaccination and 100 corresponding sera taken before vaccination were tested in the PRNT50, the Euroimmun anti-JEV IgG IIFT, and the InBios JE Detect IgG ELISA. The Euroimmun IgM IIFT showed in comparison to the Panbio ELISA a specificity of 95% and a sensitivity of 86%. With respect to the InBios ELISA, the values were 100% and 83.9%, respectively. The analysis of the Euroimmun IgG IIFT performance and the PRNT50 results demonstrated a specificity of 100% and a sensitivity of 93.8%, whereas it was not possible to detect more than 6.6% of the PRNT50 positive sera as positive with the InBios JE Detect IgG ELISA. Thus, the IIFT is a valuable alternative to the established methods in detecting anti-JEV antibodies after vaccination in travellers and it might prove useful for the diagnosis of acutely infected persons.  相似文献   

16.
An enzyme linked immunosorbent assay (ELISA) was used to evaluate antibody positive titer in vaccinated and non-vaccinated cattle using schizont infected myeloid cells as an antigen. The result was compared with indirect fluorescent antibody level in the same animals. For this study 116 milking cows, 95 vaccinated and 21 non-vaccinated, were bleeded in order to prepare sera. They were tested with both ELISA and IFA tests. 94 sera had positive antibody titer and 22 sera were negative through ELISA test but, with IFA test, only 89 sera showed positive antibody titer and 27 were negative. Thereby, it was concluded that the sensitivity and specificity of ELISA test in comparison with IFA test was 95.5% and 66.6% respectively. This study generally indicated that ELISA could be an effective test for sero-epidemiological investigations of bovine tropical theileriosis, and it is considered to be valid as an additional test to distinguish the vaccinated from the non vaccinated cattle in order to schedule vaccination programs.  相似文献   

17.
Examinations of 297 sera for diphtheria antitoxin and 160 sera for tetanus antitoxin were carried out in 1981. All sera were obtained from the cord blood of mothers between 15 and 34 years of age. The mothers were divided into four age groups each of which was further subdivided into the primipara and multipara subgroups. The aim was to assess the age-specific variations in response to active immunization against diphtheria and tetanus. The protective level of diphtheria antitoxin (at least 0.01 I.U./ml) was recorded in the serum of 96.3% of examinees and the rates of seropositivity were found to fall with increasing age. The protective level of tetanus antitoxin (at least 0.1 I.U./ml) was found in the serum of 95.2% of mothers. The serologic response encountered in groups of older mothers was a clear-cut demonstration that the country-wide mass immunization against tetanus carried out between 1974 and 1975 was highly effective and fully justified. The variations in the diphtheria and tetanus antitoxin levels found in the primipara and multipara subgroups were not statistically significant.  相似文献   

18.
作者建立了一套适用于破伤风抗毒素效力检测的双抗原夹心ELISA法,对破伤风类毒素免疫后的豚鼠和马匹分别进行了血清效价测定,并和传统的小鼠攻毒法的效力检测进行了比较,结果表明:该检测方法与小鼠攻毒法对不同水平的破伤风抗毒素效力检测,结果是一致的,有很好的相关性;此法省时、特异、灵敏,可成为另一种检测破伤风抗毒素的有效方法。  相似文献   

19.
The results of a study of the immunity to diphtheria of 283 girls (9-18 years of age) vaccinated at the age of two years with three doses of vaccine, are reported. The rabbit skin test was used to determine the titre of serum diphtheria antitoxin. 55.8% of the subjects were found to be protected (titre greater than or equal to 0.1 IU/ml), 38.9% were only relatively immune (titre greater than or equal to 0.01- less than 0.01 IU/ml), and 5.3% were unprotected (titre less than 0.01 IU/ml). The antitoxin titres showed a tendency to decrease with time. Even so, 6-15 years after vaccination, the percentages of protected and partially protected subjects were still high (95%).  相似文献   

20.
Neonatal tetanus despite protective serum antitoxin concentration   总被引:1,自引:0,他引:1  
Using the ELISA technique to estimate serum antibodies against tetanus toxin, seven neonates with clinical tetanus were found to have antibody levels 4-13 times higher than the presumed minimum protective level of 0.01 IU/ml. All but one of their mothers had been vaccinated with tetanus toxoid in pregnancy. In two other neonates, whose mothers had received multiple booster doses of toxoid during pregnancy, the anti-toxin concentrations were 100- and 400-times the presumed protective level. Therefore the toxin dose may overwhelm the pre-existing anti-toxin level and produce disease. Furthermore, multiple booster injections of tetanus toxoid may not only enhance serum anti-toxin titres, but could also lead to an ineffective immune response.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号