首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A method for the combined determination of the mycotoxins aflatoxin B1, G1, B2, G2, ochratoxin A and zearalenone in cereals and feed is described. After extraction with acetonitrile/water or methanol/water the cleaning takes place with new combined immunoaffinity clean-up column “AflaOchraZea” by VICAM. When the mycotoxins are determined in different cereals with this new type of clean-up column low detection limits and high recovery rates can be reached similar to those obtained by using separate immunoaffinity clean-up colums for the said mycotoxins.  相似文献   

2.
Gel permeation chromatography has been used to clean up extracts from cereals and animal feeds containing a range of mycotoxins. A mixture of dichloromethane: IM hydrochloric acid, 10:1 by volume is used as the extraction solvent and clean-up is carried out on a Bio — Beads S-X3 column using dichloromethane: ethyl acetate containing a small amount of formic acid as the elution solvent. Chromatographic separation and detection was by HPLC with fluorescence or ultraviolet detection although the choice of detection method is left to the user. The method has been tested for 14 mycotoxins and results are presented for cereals fortified with mycotoxins and for samples naturally contaminated with aflatoxins, citrinin, zearalenone, and ochratoxin A.  相似文献   

3.
Direct plasma injection technology coupled with a LC-MS/MS assay provides fast and straightforward method development and greatly reduces the time for the tedious sample preparation procedures. In this work, a simple and sensitive bioanalytical method based on direct plasma injection using a single column high-performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) was developed for direct cocktail analysis of double-pooled mouse plasma samples for the quantitative determination of small molecules. The overall goal was to improve the throughput of the rapid pharmacokinetic (PK) screening process for early drug discovery candidates. Each pooled plasma sample was diluted with working solution containing internal standard and then directly injected into a polymer-coated mixed-function column for sample clean-up, enrichment and chromatographic separation. The apparent on-column recovery of six drug candidates in mouse plasma samples was greater than 90%. The single HPLC column was linked to either an atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI) source as a part of MS/MS system. The total run cycle time using single column direct injection methods can be achieved within 4 min per sample. The analytical results obtained by the described direct injection methods were comparable with those obtained by semi-automated protein precipitation methods within +/- 15%. The advantages and challenges of using direct single column LC-MS/MS methods with two ionization sources in combination of sample pooling technique are discussed.  相似文献   

4.
The natural occurrence of alternariol (AOH) and alternariol monomethyl ether (AME) in soya beans harvested in Argentina was evaluated. Both toxins were simultaneously detected by using HPLC analysis coupled with a solid phase extraction column clean-up. Characteristics of this in-house method such as accuracy, precision and detection and quantification limits were defined by means of recovery test with spiked soya bean samples. Out of 50 soya bean samples, 60% showed contamination with the mycotoxins analyzed; among them, 16% were only contaminated with AOH and 14% just with AME. Fifteen of the positive samples showed co-occurrence of both mycotoxins analyzed. AOH was detected in concentrations ranging from 25 to 211?ng/g, whereas AME was found in concentrations ranging from 62 to 1,153?ng/g. Although a limited number of samples were evaluated, this is the first report on the natural occurrence of Alternaria toxins in soya beans and is relevant from the point of view of animal public health.  相似文献   

5.
A sensitive method for the simultaneous determination of T-2 toxin, HT-2 toxin, neosolaniol, T-2 triol, and T-2 tetraol in layer feed using high-performance liquid chromatography coupled to triple quadrupole mass spectrometry in the positive ionization mode (LC-ESI-MS/MS) is described. Two fast and easy clean-up methods—with BondElut Mycotoxin and MycoSep 227 columns, respectively—were tested. The separation of the toxins was conducted on a Pursuit XRs Ultra 2.8 HPLC column using 0.13 mM ammonium acetate as eluent A and methanol as eluent B. Detection of the mycotoxins was carried out in the multiple reaction monitoring (MRM) mode using ammonium adducts as precursor ions. Quantification of all analytes was performed with d3-T-2 toxin as an internal standard. The clean-up method with MycoSep 227 columns gave slightly better results for layer feed compared to the method using BondElut Mycotoxin columns (MycoSep 227: recovery between 50 and 63 %, BondElut Mycotoxin: recovery between 32 and 67 %) and was therefore chosen as the final method. The limits of detection ranged between 0.9 and 7.5 ng/g depending on the mycotoxin. The method was developed for the analysis of layer feed used at carry-over experiments with T-2 toxin in laying hens. For carry-over experiments, it is necessary that the method includes not only T-2 toxin but also the potential metabolites in animal tissues HT-2 toxin, neosolaniol, T-2 triol, and T-2 tetraol which could naturally occur in cereals used as feed stuff as well.  相似文献   

6.
Advances in microsystem technology have enabled protein and nucleic acid-based microarrays to be used in various applications, including the study of diseases, drug discovery, genetic screening, and clinical and food diagnostics. Analytical methods for the detection of mycotoxins, however, remain largely based on thin layer chromatography (TLC), high pressure liquid chromatography (HPLC), or enzyme-linked Immunosorbent assay (ELISA) . The aim of our work, therefore, was to transfer an immunological assay from microtitrr plates into microarray format, in order to develop a multiparametric, rapid, sensitive and inexpensive method for the detection of mycotoxins for use in food safety applications. Microarray technology enables the fast and parallel analysis of a multitude of biologically relevant parameters. Not only nucleic acid-based tests but also peptide, antigen, and antibody assays, using different formats of microarrays, have evolved within the last decade. Antibody-based microarrays provide a powerful tool that can be used to generate rapid and detailed expression profiles of a defined set of analytes in complex samples and are potentially useful for generating rapid immunological assays of food contaminants. In this paper, we report a feasibility study of the application of antibody microarrays for the simultaneous (or independent) detection of two common mycotoxins, Aflatoxin B1 and Fumonisin B1. We present the development of microarray detection of aflatoxin B1 and fumonisin B1 in standard solutions with detection limits of 3 ng/ml of AFB1 and 43 ng/ml for FB1, and have developed a competitive immunoassay in microarray format for simultaneous analyses. The quality of the microarray data is comparable to data generated by microplate-based immunoassay (ELISA), but further investigations are needed in order to characterise our method more fully. We hope that these preliminary results might suggest that further research is warranted in order to develop hapten microarrays for the immunochemical simultaneous analysis of mycotoxins, as well as for other small molecules (e.g. bacterial toxins or biological warfare agents).  相似文献   

7.
WIN 33377 (I) is a member of a novel class cytotoxic antitumor agents, 4-aminomethyl thioxanthane derivatives. A simple, rapid and reproducible method has been developed for the assay of I in mouse plasma using a high-performance liquid chromatographic method utilizing a column-switching technique. The method involves direct injection of buffered plasma to the extraction column for sample clean-up followed by switching onto an analytical column for analysis with UV detection at 256 nm. The method has demonstrated accuracy and precision over the range 10–2500 ng/ml using a 100-μl plasma sample with a minimum quantifiable level at 10 ng/ml. Stability of mouse plasma samples was demonstrated after storage for 4 weeks at −15 to −20°C, as was the ability of samples to be accurately quantified after a maximum of three freeze-thaw cycles. Recovery was greater than 87% for the compound and the internal standard. The assay was accurate and reproducible with measured values lying within the limits of defined acceptance criteria. The utility of the method was demonstrated by analyzing plasma samples obtained from mice dosed with I as part of a pre-clinical safety study intended to assist in the design of a pharmacokinetically guided dose escalation strategy.  相似文献   

8.
A column-switching high-performance liquid chromatographic assay is described for the determination of ceftazidime (a third-generation cephalosporin) in human serum. The method does not require prior sample pretreatment. Serum is directly injected in a first chromatographic column for sample clean-up and extraction. Thereafter, using an on-line column-switching system, the drug is quantitatively transferred and separated on a second, analytical column followed by determination using ultraviolet absorption at 258 nm. The technique allows direct, rapid, precise, and simple determination of ceftazidime in serum over the range of 1–250 μg/ml using 12.5 μl of serum. This method was applied to study the pharmacokinetics of the drug in patients undergoing vascular surgery.  相似文献   

9.
Fusarium fungi are widely found in agricultural products, worldwide and can produce a great variety of mycotoxins. Fumonisins, produced by F. moniliforme, and deoxynivalenol, produced by F. graminearum, are two such mycotoxins that have received considerable attention as food safety concerns by regulatory agencies. High Performance Liquid Chromatography/Mass Spectrometry (HPLC/MS) was found to be a convenient analytical method to detect and quantify the naturally occurring fumonisin homologs and deoxynivalenol in extracts from grains and food products. The fumonisins are detected primarily as protonated molecules in the positive ion electrospray ionization (ESI) mode as they elute from a C-18 reverse phase column during a methanol water gradient containing acetic acid to facilitate chromatography. Deoxynivalenol can be detected as positive or negative ions in the atmospheric pressure chemical ionization (APCI) mode or in the negative ion ESI mode. One nanogram amounts of fumonisins or deoxynivalenol injected into the HPLC system are easily detected with signal to noise allowing detection limits of 1 microg g(-1) or better to easily be achieved with minimal clean-up of grain extracts.  相似文献   

10.
The therapeutic use of disulfhydryl compounds such as 2,3-dimercaptosuccinic acid (DMSA) for the treatment of heavy metal poisoning has generated a requirement for specific and sensitive methods to determine those compounds in biological media. We have developed a gas chromatographic assay for DMSA in urine. The use of capillary column technology eliminates the requirement for a preliminary clean-up step. Samples are first reduced electrochemically to liberate DMSA present as disulfides. The reduced product is then extracted into ethyl acetate and the organic phase removed by evaporation. The residue is derivatized with N,O-bis(trimethylsilyl)acetamide for gas chromatography. The silylated DMSA derivative is then detected with a flame ionization detector. The detection limit for DMSA is 1.9 nmol per 1-μl aliquot of derivatized extract injected on column (detector sensitivity at 1·10−11 A/mV). The utility of the method was demonstrated by analyzing the urine of rats orally dosed with DMSA.  相似文献   

11.
This review provides a critical assessment of the applications of immunoaffinity columns for sample clean-up in the field of food safety. The performance of immunoaffinity columns are compared in terms of specificity, binding capacity and recovery, and commercial disposable columns are contrasted with home-made columns. Areas covered include multiple-use of columns, multiple-analyte columns, use with automated systems and validation of IAC methods. Publications illustrating the many varied applications of IAC for sample clean-up in the areas of mycotoxins, veterinary drug residues, pesticide residues, environmental contaminants and vitamins have been compiled, comparing extraction methods, achievable recovery, and illustrating the variety of end-detection methods that have been employed.  相似文献   

12.
Fumonisins are mycotoxins that are produced by various Fusarium species and occur naturally in maize and maize-based foods. Fumonisins are carcinogenic, causing liver cancer in rats, and are associated with oesophageal cancer and neural tube defects in humans. Analytical methods for individual fumonisin analogues in maize rely on reversed-phase high-performance liquid chromatographic (HPLC) separation after suitable extraction and clean-up. As fumonisins lack a useful chromophore or fluorophore, HPLC detection is achieved by suitable derivatization and sensitive, specific fluorescence detection. A widely used and validated method involves extract clean-up on strong anion exchange solid phase extraction cartridges and pre-column derivatization with o-phthaldialdehyde (OPA). However, many laboratories requiring infrequent fumonisin analysis are only equipped with HPLC with ultraviolet (UV) detection. A HPLC system equipped with both UV and fluorescence detectors connected in series was used to determine the extent to which UV offers an alternative to fluorescence detection in the above analytical method. Comparison of the detection systems using fumonisin standards indicated that fluorescence is about 20-times more sensitive than UV. Analysis of maize samples with differing fumonisin contamination levels indicated that, at fumonisin B1 levels above 1,000 μg/kg, the two detection systems were comparable and gave repeatabilities equal or less than 10% on six replicate analyses. Although a sensitive fumonisin analysis requires fluorescence detection, UV may offer an alternative in certain circumstances.  相似文献   

13.
A simple and rapid method for the determination of serum amino acids by gas chromatography (GC) has been developed. Following deproteinization of serum with perchloric acid, free amino acids in the supernatant were converted into their N(O,S)-isobutoxycarbonyl methyl ester derivatives and measured by GC with flame ionization detection using a DB-17 capillary column. All the derivatives of the 22 protein amino acids were completely resolved as single peaks within 9 min by GC. The calibration curves were linear in the range 0.2–50 μg of each amino acid, and the correlation coefficients were above 0.998. By using this method, serum amino acids could be directly analysed without prior clean-up procedure such as ion-exchange column chromatography except for deproteinization of the samples, and without any interference from coexisting substances. Overall recoveries of amino acids added to serum samples were 88–108%. Analytical results for serum amino acids from normal subjects are presented.  相似文献   

14.
Summary  An enzyme linked immunosorbent assay (ELISA) method and a thin-layer chromatography (TLC) method with two different clean-up procedures have been used to analyse maize samples (food and feeding stuff) obtained from Bulgaria. The occurrence of Fumonisin B1 in Bulgarian maize was found to be in the range of what was reported for other European regions with a mean value of 1.5 mg/kg, 2.1 mg/kg and 1.8 mg/kg when analysed by ELISA and thin-layer chromatography with solid phase extraction clean up and immunoaffinity clean up, respectively. It was shown that results of the different methods are comparable, indicating that the methods applied are sufficiently reliable tools for the simple and rapid screening of maize samples.  相似文献   

15.
Fumonisins are mycotoxins produced by various species of Fusarium and occur naturally in contaminated maize and maize-based foods. Ingestion of fumonisins has considerable health implications for humans and animals. Since fumonisins lack a useful chromophore or fluorophore, their determination in maize is routinely achieved via HPLC with fluorescence detection (FLD) after precolumn derivatization. This study optimized naphthalene-2,3-dicarboxaldehyde (NDA) derivatization of fumonisins in naturally contaminated maize following strong anion exchange (SAX) solid phase extraction (SPE) clean-up and utilizing diode array detection (DAD) as a practical alternative simultaneously to FLD. The limit of detection (LOD) for fumonisin B(1) (FB(1)), fumonisin B(2) (FB(2)) and fumonisin B(3) (FB(3)) with FLD was 0.11 ng, 0.50 ng and 0.27 ng, respectively, and with DAD it was 13.8 ng, 12.5 ng and 6.6 ng, respectively injected on column. The coefficient of variation (CV, n = 6) for FB(1), FB(2) and FB(3) in a naturally contaminated samples obtained with FLD was 2.6%, 1.8% and 5.3%, respectively, compared to 6.0%, 3.4% and 9.5%, respectively, obtained with DAD. Subsequently the optimized NDA derivatization was compared to the widely used o-phthaldialdehyde (OPA) derivatization agent as well as alternative sample clean-up with immunoaffinity column (IAC) by analyzing naturally contaminated maize samples (n = 15) ranging in total fumonisin (TFB = FB(1)+FB(2)+FB(3)) levels from 106 to 6000 μg/kg. After immunoaffinity column clean-up of extracted samples, the recoveries of spiked maize samples for NDA-FLD of FB(1), FB(2) and FB(3) were 62%, 94% and 64%, respectively. NDA proved to be an effective derivatization reagent of fumonisin in naturally contaminated maize samples following IAC clean-up, except for DAD at TFB levels below 1000 μg/kg. In contrast NDA derivatization following SAX clean-up produced results comparable to OPA only for levels below 1000 μg/kg. Aside from the difference in detection limits, FLD and DAD produced comparable results irrespective of the clean-up method or the derivatization agent.  相似文献   

16.
A rapid and simple method for the determination of α1-acid glycoprotein (AAG) in serum was developed by using an anion-exchange column for clean-up of serum and a hydroxyapatite column for high-performance liquid chromatography (HPLC). A good correlation was observed between this HPLC method and the conventional radial immunodiffusion method. The method may also be used to determine the AAG concentration in the serum of experimental animals.  相似文献   

17.
Mycotoxins are known to affect the health of humans and husbandry animals. In contrast to wheat grains used for food and feed, whole wheat plants are rarely analysed for mycotoxins, although contaminated straw could additionally expose animals to these toxic compounds. Since the entire wheat plant may also act as source of mycotoxins emitted into the environment, an analytical method was developed, optimised and validated for the analysis of 28 different mycotoxins in above-ground material from whole wheat plants. The method comprises solid-liquid extraction and a clean-up step using a Varian Bond Elut Mycotoxin® cartridge, followed by liquid chromatography with electrospray ionisation and triple quadrupole mass spectrometry. Total method recoveries for 26 out of 28 compounds were between 69 and 122% and showed limits of detection from 1 to 26 ng/gdry weight (dw). The overall repeatability for all validated compounds was on average 7%, and their mean ion suppression 65%. Those rather high matrix effects made it necessary to use matrix-matched calibrations to quantify mycotoxins within whole wheat plants. The applicability of this method is illustrated with data from a winter wheat test field to examine the risks of environmental contamination by toxins following artificial inoculation separately with four different Fusarium species. The selected data originate from samples of a part of the field which was inoculated with Fusarium crookwellense. In the wheat samples, various trichothecenes (3-acetyl-deoxynivalenol, deoxynivalenol, diacetoxyscirpenol, fusarenone-X, nivalenol, HT-2 toxin, and T-2 toxin) as well as beauvericin and zearalenone were identified with concentrations ranging from 32 ng/gdw to 12 × 103 ng/gdw.  相似文献   

18.
Validation of two HPLC assays for the quantitation of carboplatin in human plasma ultrafiltrate is described. Both assay methods employed a YMC ODS-AQ 3.9×150 mm (3 μm) column for the chromatographic separation. The first method utilized direct UV detection, the second method utilized UV detection following post-column derivatization with sodium bisulfite. Structural analogues of carboplatin were synthesized and used as internal standards for the assays. With direct UV detection, sample clean-up using solid-phase extraction on amino cartridges was required prior to injection, with extraction recoveries ranging from 80 to 90%. This extraction procedure was not necessary with the post-column reaction method, which employed a more selective analytical wavelength. Unfortunately, instability of the post-column reagent was a problem and led to greater variability in predicted concentration values. For standard curves, a weighted (1/y2) regression approach was used for plots of peak area or peak height ratio (carboplatin/internal standard) vs. carboplatin concentration. The limit of detection of both assays was 0.025 μg/ml and both were validated for carboplatin concentrations from 0.05 to 40 μg/ml. Accuracy and precision data were generated using three batches of validation samples, each batch consisting of a standard curve and five sets of quality control samples. Stability of carboplatin in blood, plasma, plasma ultrafiltrate, and reconstituted extracts was evaluated. The assay methods were employed for the pharmacokinetic analysis of blood samples drawn from a pediatric patient that received a 400 mg/m2 dose of carboplatin.  相似文献   

19.
A method is described for the determination of urinary hippuric acid by high-performance liquid chromatography. The method used ethyl acetate extraction for partial clean-up of the urine. The separation was carried out on a reversed-phase column using 20% methanol in 0.01 M aqueous potassium phosphate containing 0.5% acetic acid as a mobile phase. The column effluent was monitored with a UV detector at 254 nm. Hippuric acid was separated from other normal urine constituents in less than 10 min. Metabolites of xylene and styrene did not interfere with the assay. Analytical recoveries from urine were excellent and peak height and concentration were linearly related.  相似文献   

20.
A simple and innovative assay is described which allows the chiral separation of the four enantiomers of fluoxetine and norfluoxetine, with performance characteristics adequate for therapeutic drug monitoring. The assay requires liquid-liquid extraction into acetonitrile/n-hexane/isopropylic alcohol and re-extraction into phosphoric acid for clean-up. The acidic layer is injected onto the HPLC system after filtering. Separation of the analytes is achieved with a Chiralcel ODR column and a mobile phase consisting of potassium hexafluorophosphate/acetonitrile. Detection is made by ultraviolet absorbance at 227 nm. Standard curves are linear for each enantiomer (r(2)>/=0.992) over the range of 10-1000 ng/ml with a limit of quantification of 10 ng/ml for each enantiomer. Within-day and between-day CV% are 相似文献   