首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Mesenchymal stem cells produce proinflammatory cytokines during their normal growth. Direct or indirect regulation of bone resorption by these cytokines has been reported. However, the effects of osteogenic conditions—chemical and/or mechanical—utilized during in vitro bone tissue engineering on expression of cytokines by hMSCs have not been studied. In this study, we investigated the effects of cyclic tensile strain, culture medium (with and without dexamethasone), and culture duration on the expression of tumor necrosis factor‐α (TNF‐α), interleukin‐1β (IL‐1β), interleukin‐6 (IL‐6), and interleukin‐8 (IL‐8) by bone marrow derived human mesenchymal stem cells (hMSCs). Human MSCs seeded in three‐dimensional Type I collagen matrices were subjected to 0%, 10%, and 12% uniaxial cyclic tensile strains at 1 Hz for 4 h/day for 7 and 14 days in complete growth or dexamethasone‐containing osteogenic medium. Viability of hMSCs was maintained irrespective of strain level and media conditions. Expression of either TNF‐α or IL‐1β was not observed in hMSCs under any of the conditions investigated in this study. Expression of IL‐6 was dependent on culture medium. An increase in IL‐6 expression was caused by both 10% and 12% strain levels. Both 10% and 12% strain levels caused an increase in IL‐8 production by hMSCs that was dependent on the presence of dexamethasone. IL‐6 and IL‐8 expressions by hMSCs were induced by cyclic tensile strain and osteogenic differentiating media, indicating that IL‐6 and IL‐8 may be functioning as autocrine signals during osteogenic differentiation of hMSCs. J. Cell. Physiol. 219: 77–83, 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

2.
Human adipose-derived stem cells (hASC) exhibit multilineage differentiation potential with lineage specification that is dictated by both the chemical and mechanical stimuli to which they are exposed. We have previously shown that 10% cyclic tensile strain increases hASC osteogenesis and cell-mediated calcium accretion. We have also recently shown that primary cilia are present on hASC and that chemically-induced lineage specification of hASC concurrently results in length and conformation changes of the primary cilia. Further, we have observed cilia length changes in hASC cultured within a collagen I gel in response to 10% cyclic tensile strain. We therefore hypothesize that primary cilia may play a key mechanotransduction role for hASC exposed to tensile strain. The goal of this study was to use finite element analysis (FEA) to determine strains occurring within the ciliary membrane in response to 10% tensile strain applied parallel, or perpendicular, to cilia orientation. To elucidate the mechanical environment experienced by the cilium, several lengths were modeled and evaluated based on cilia lengths measured on hASC grown under varied culture conditions. Principal tensile strains in both hASC and ciliary membranes were calculated using FEA, and the magnitude and location of maximum principal tensile strain determined. We found that maximum principal tensile strain was concentrated at the base of the cilium. In the linear elastic model, applying strain perpendicular to the cilium resulted in maximum strains within the ciliary membrane from 150% to 200%, while applying strain parallel to the cilium resulted in much higher strains, approximately 400%. In the hyperelastic model, applying strain perpendicular to the cilium resulted in maximum strains within the ciliary membrane around 30%, while applying strain parallel to the cilium resulted in much higher strains ranging from 50% to 70%. Interestingly, FEA results indicated that primary cilium length was not directly related to ciliary membrane strain. Rather, it appears that cilium orientation may be more important than cilium length in determining sensitivity of hASC to tensile strain. This is the first study to model the effects of tensile strain on the primary cilium and provides newfound insight into the potential role of the primary cilium as a mechanosensor, particularly in tensile strain and potentially a multitude of other mechanical stimuli beyond fluid shear.  相似文献   

3.
Glycosphingolipids (GSLs) are ubiquitous membrane components that play an indispensable role in maintaining chondrocyte homeostasis. To gain better insight into roles of GSLs, we studied the effects of GSL-deletion on the physiological responses of chondrocytes to mechanical stress. Mice lacking Ugcg gene (Ugcg-/-) were genetically generated to obtain GSL-deficient mice, and their chondrocytes from the joints were used for functional analyses in vitro culture experiments. The cells were seeded in a three-dimensional collagen gel and subjected to 5%, 10% or 16% cyclic tensile strain for either 3 or 24 h. The gene expressions of chondrocyte anabolic and catabolic factors, and the induction of Ca2+ signaling were analyzed. Our results revealed that chondrocytes derived from GSL-deficient mice exhibited an elevation in the expression of catabolic factors (ADAMTS-5, MMP-13) following the exposure to strain with amplitudes of 10%. Likewise, applying cyclic tensile strain with these amplitudes resulted in an increased Ca2+ oscillation ratio in chondrocytes from GSL-deficient as compared to the ratio from control mice. These results demonstrated that deletion of GSL stimulated the catabolic responses of chondrocytes to mechanical stress via the augmentation of the sensitivity to mechanical stress that may lead to the cartilage deterioration. These findings suggest that the regulation of the physiological responses of chondrocytes by GSLs could be a potential target in a therapeutic intervention in osteoarthritis.  相似文献   

4.
Strain-related collagen gene expression in human osteoblast-like cells   总被引:2,自引:0,他引:2  
The gene expression of cells in the musculoskeletal system, such as in bone, cartilage, ligament and tendon, is profoundly affected by mechanical loading. Previous studies have demonstrated that the expression of many genes, including collagen types I and III, are affected by mechanical strain in diverse cell types, such as human osteoblast-like SaOs-2 cells. However, whether the effect of mechanical loading on collagen gene expression is strain-related remains unclear. The goal of this study was to determine the relationship between mechanical strain and the gene expression of collagen types I and III in SaOs-2 cells. A Flexercell cellular mechanical loading system was used to subject SaOs-2 cells to equibiaxial cyclic tensile stress at a rate of 0.5 Hz with various strains of 5%, 7.5%, 10%, and 12.5% for 24 h. The relative amount of mRNA of both collagen I and collagen III increased at 5% strain compared with that of the control. As the strain increased, the relative amount of mRNA of collagen I remained stable at strain levels up to 12.5%. However, the mRNA for collagen III began to drop when the strain was greater than 5%, until a 10% strain was reached. From the application of a 10% strain through the maximum loading of a 12.5% strain, the relative amount of collagen III mRNA remained stable at amounts lower than that of the control. Thus, the gene expression of collagen types I and III responds differentially to mechanical strain at various magnitudes.  相似文献   

5.
Mechanical stimulation is considered to be one of the major epigenetic factors regulating the metabolism, proliferation, survival and differentiation of cells in the skeletal tissues. It is generally accepted that the cytoskeleton can undergo remodeling in response to mechanical stimuli such as tensile strain or fluid flow. Mechanically induced cell deformation is one of the possible mechanotransduction pathways by which chondrocytes sense and respond to changes in their mechanical environment. Mechanical strain has a variety of effects on the structure and function of their cells in the skeletal tissues, such as chondrocytes, osteoblasts and fibroblasts. However, little is known about the effect of the quality and quantity of mechanical strain and the timing of mechanical loading on the differentiation of these cells. The present study was designed to investigate the effect of the deformation of chondrogenic cells, and cyclic compression using a newly developed culture device, by analyzing mechanobiological response to the differentiating chondrocytes. Cyclic compression between 0 and 22% strains, at 23 microHz was loaded on chondrogenic cell line ATDC5 by seeding in a mass mode on PDMS membrane, assuming direct transfer of cyclic deformation from the membrane to the cells at the same frequency. The compressive strain, induced within the membrane, was characterized based on the analysis of the finite element modeling (FEM). The results showed that the tensile strain inhibits the chondrogenic differentiation of ATDC5 cells, whereas the compressive strain enhances the chondrogenic differentiation, suggesting that the differentiation of the chondrogenic cells could be controlled by the amount and the mode of strain. In conclusion, we have developed a unique strain loading culture system to analyze the effect of various types of mechanical stimulation on various cellular activities.  相似文献   

6.
Many biological consequences of external mechanical loads applied to cells depend on localized cell deformations rather than on average whole-cell-body deformations. Such localized intracellular deformations are likely to depend, in turn, on the individual geometrical features of each cell, e.g., the local surface curvatures or the size of the nucleus, which always vary from one cell to another, even within the same culture. Our goal here was to characterize cell-to-cell variabilities in magnitudes and distribution patterns of localized tensile strains that develop in the plasma membrane (PM) and nuclear surface area (NSA) of compressed myoblasts, in order to identify resemblance or differences in mechanical performances across the cells. For this purpose, we utilized our previously developed confocal microscopy-based three-dimensional cell-specific finite element modeling methodology. Five different C2C12 undifferentiated cells belonging to the same culture were scanned confocally and modeled, and were then subjected to compression in the simulation setting. We calculated the average and peak tensile strains in the PM and NSA, the percentage of PM area subjected to tensile strains above certain thresholds and the coefficient of variation (COV) in average and peak strains. We found considerable COV values in tensile strains developing at the PM and NSA (up to ~35%) but small external compressive deformations induced greater variabilities in intracellular strains across cells compared to large deformations. Interestingly, the external deformations needed to cause localized PM or NSA strains exceeding each threshold were very close across the different cells. Better understanding of variabilities in mechanical performances of cells-either of the same type or of different types-is important for interpreting experimental data in any experiments involving delivery of mechanical loads to cells.  相似文献   

7.
To support and enhance thein vitro growth and activity of mesenchymal stem cells (MSCs), the cell culture medium may be supplemented with various proteins and factors to mimic the physiological environment in which the cells optimally proliferate and differentiate. In this study, the effects of mechanical factors on cellular metabolic responses were investigated experimentally using a bioreactor. The effects of various chemical factors, such as growth factors, cytokines, and hormones, were also investigated. Based on previous reports demonstrating the important roles of mechanical factors in the growth and activity of MSCs, we sought to evaluate the effects of mechanical stimuli on the proliferation of bone marrow-derived MSCs using a cell training bioreactor that imposed cyclic mechanical stretch, with parameters of 240 min/day, 0.03 Hz, and 5–15% strain. The application of cyclic stretch (5–15% strain) to the MSCs enhanced their proliferation during the early stage (3 days), but not the late stage (14 days), of batch culture. Mechanical stretch did not increase the release of lactate dehydrogenase (LDH) from the MSCs during culture. Appropriate levels of mechanical stretch (5–10% strain) increased collagen synthesis, but did not alter MSC surface antigen expression. It is thought that the appropriate level of mechanical stretch was able to serve as a potent positive modulator of MSC proliferation during the initial stages of culture.  相似文献   

8.
The objective of this study was to develop a finite-element (FE) modeling methodology for studying the etiology of a stress fracture (SF). Several variants of three-dimensional FE models of a rat hindlimb, which differed in length or stiffness of tissues, enabling the analyses of mechanical strains and stress in the tibia, were created. We compared the occurrence of SFs in an animal model to validate locations of peak strains/stresses in the FE models. Four Sprague-Dawley male rats, age ~7 wk, were subjected to mechanical cyclic loads of 1.2 Hz and ~6 N, which were delivered to their hindlimb for 30 min, 3 times/wk, up to 12 wk, by using a specially designed apparatus. The results showed that 1) FE modeling predicted the maximal strains/stresses (~220,0 με and ~29 MPa, respectively) between the mid- and proximal thirds of the tibia; 2) in a longer shin, greater and more inhomogeneous tensile strains/stresses were evident, at the same location; 3) anatomical variants in shin length influenced the strain/stress distributions to a greater extent with respect to changes in mechanical properties of tissues; and 4) bone stiffness was more dominant than muscle stiffness in affecting the strain/stress distributions. In the animal study, 35,000 loading cycles were associated with the formation of a SF. The location of the identified SF in the rat limb verified the FE model. We find the suggested model a valuable tool in studying various aspects of SFs.  相似文献   

9.
The mechanical properties of cancellous bone and the biological response of the tissue to mechanical loading are related to deformation and strain in the trabeculae during function. Due to the small size of trabeculae, their motion is difficult to measure. To avoid the need to measure trabecular motions during loading the finite element method has been used to estimate trabecular level mechanical deformation. This analytical approach has been empirically successful in that the analytical models are solvable and their results correlate with the macroscopically measured stiffness and strength of bones. The present work is a direct comparison of finite element predictions to measurements of the deformation and strain at near trabecular level. Using the method of digital volume correlation, we measured the deformation and calculated the strain at a resolution approaching the trabecular level for cancellous bone specimens loaded in uniaxial compression. Smoothed results from linearly elastic finite element models of the same mechanical tests were correlated to the empirical three-dimensional (3D) deformation in the direction of loading with a coefficient of determination as high as 97% and a slope of the prediction near one. However, real deformations in the directions perpendicular to the loading direction were not as well predicted by the analytical models. Our results show, that the finite element modeling of the internal deformation and strain in cancellous bone can be accurate in one direction but that this does not ensure accuracy for all deformations and strains.  相似文献   

10.
Cardiovascular disease is the leading cause of death worldwide, with multipotent vascular stem cells (MVSC) implicated in contributing to diseased vessels. MVSC are mechanosensitive cells which align perpendicular to cyclic uniaxial tensile strain. Within the blood vessel wall, collagen fibers constrain cells so that they are forced to align circumferentially, in the primary direction of tensile strain. In these experiments, MVSC were seeded onto the medial layer of decellularized porcine carotid arteries, then exposed to 10%, 1 Hz cyclic tensile strain for 10 days with the collagen fiber direction either parallel or perpendicular to the direction of strain. Cells aligned with the direction of the collagen fibers regardless of the orientation to strain. Cells aligned with the direction of strain showed an increased number of proliferative Ki67 positive cells, while those strained perpendicular to the direction of cell alignment showed no change in cell proliferation. A bioreactor system was designed to simulate the indentation of a single, wire stent strut. After 10 days of cyclic loading to 10% strain, MVSC showed regions of densely packed, highly proliferative cells. Therefore, MVSC may play a significant role in in-stent restenosis, and this proliferative response could potentially be controlled by controlling MVSC orientation relative to applied strain.  相似文献   

11.
Rapid induction of matrix production and mechanical strengthening is essential to the development of bio-artificial constructs for repair and replacement of load-bearing connective tissues. Toward this end, we describe the development of a mechanical bioreactor and its application to investigate the influence of cyclic strain on fibroblast proliferation, matrix accumulation, and the mechanical properties of fibroblast-seeded polyurethane constructs (FSPC). Human fibroblasts were cultured in 10% serum-containing conditions within three-dimensional, porous elastomeric substrates under static conditions and a model regime of cyclic strain (10% strain, 0.25 Hz, 8 h/day), with and without ascorbic acid supplementation. After one week, the combination of cyclic strain and ascorbic acid resulted in significantly increased construct elastic modulus (>110%) relative to either condition alone. In contrast, cyclic strain alone was sufficient to stimulate significant increases in fibroblast proliferation. Mechanical strengthening of FSPCs was accompanied by increased type I collagen and fibronectin matrix accumulation and distribution, and significantly increased gene expression for type I collagen, TGFbeta-1, and CTGF. These results suggest that strain-induced conditioning in vitro leads to mechanical strengthening of fibroblast/material constructs, most likely resulting from increased collagen matrix deposition, secondary to strain-induced increases in cytokine production.  相似文献   

12.
13.
The widespread availability of three-dimensional imaging and computational power has fostered a rapid increase in the number of biologists using finite element analysis (FEA) to investigate the mechanical function of living and extinct organisms. The inevitable rise of studies that compare finite element models brings to the fore two critical questions about how such comparative analyses can and should be conducted: (1) what metrics are appropriate for assessing the performance of biological structures using finite element modeling? and, (2) how can performance be compared such that the effects of size and shape are disentangled? With respect to performance, we argue that energy efficiency is a reasonable optimality criterion for biological structures and we show that the total strain energy (a measure of work expended deforming a structure) is a robust metric for comparing the mechanical efficiency of structures modeled with finite elements. Results of finite element analyses can be interpreted with confidence when model input parameters (muscle forces, detailed material properties) and/or output parameters (reaction forces, strains) are well-documented by studies of living animals. However, many researchers wish to compare species for which these input and validation data are difficult or impossible to acquire. In these cases, researchers can still compare the performance of structures that differ in shape if variation in size is controlled. We offer a theoretical framework and empirical data demonstrating that scaling finite element models to equal force: surface area ratios removes the effects of model size and provides a comparison of stress-strength performance based solely on shape. Further, models scaled to have equal applied force:volume ratios provide the basis for strain energy comparison. Thus, although finite element analyses of biological structures should be validated experimentally whenever possible, this study demonstrates that the relative performance of un-validated models can be compared so long as they are scaled properly.  相似文献   

14.
The ability to predict trabecular failure using microstructure-based computational models would greatly facilitate study of trabecular structure–function relations, multiaxial strength, and tissue remodeling. We hypothesized that high-resolution finite element models of trabecular bone that include cortical-like strength asymmetry at the tissue level, could predict apparent level failure of trabecular bone for multiple loading modes. A bilinear constitutive model with asymmetric tissue yield strains in tension and compression was applied to simulate failure in high-resolution finite element models of seven bovine tibial specimens. Tissue modulus was reduced by 95% when tissue principal strains exceeded the tissue yield strains. Linear models were first calibrated for effective tissue modulus against specimen-specific experimental measures of apparent modulus, producing effective tissue moduli of (mean±S.D.) 18.7±3.4 GPa. Next, a parameter study was performed on a single specimen to estimate the tissue level tensile and compressive yield strains. These values, 0.60% strain in tension and 1.01% strain in compression, were then used in non-linear analyses of all seven specimens to predict failure for apparent tensile, compressive, and shear loading. When compared to apparent yield properties previously measured for the same type of bone, the model predictions of both the stresses and strains at failure were not statistically different for any loading case (p>0.15). Use of symmetric tissue strengths could not match the experimental data. These findings establish that, once effective tissue modulus is calibrated and uniform but asymmetric tissue failure strains are used, the resulting models can capture the apparent strength behavior to an outstanding level of accuracy. As such, these computational models have reached a level of fidelity that qualifies them as surrogates for destructive mechanical testing of real specimens.  相似文献   

15.
The ability of bone to adapt to its mechanical environment is well recognized, although the specific mechanical parameters initiating or maintaining the adaptive responses have yet to be identified. Recently introduced mathematical models offer the potential to aid in the identification of such parameters, although these models have not been well validated experimentally or clinically. We formulated a complementary experimental/analytic approach, using an animal model with a well-controlled mechanical environment combined with finite element modeling (FEM). We selected the functionally isolated turkey ulna, since the loading could be completely characterized and the periosteal adaptive responses subsequently monitored and quantified after four and eight weeks of loading. Known loads input into a three-dimensional, linearly elastic FEM of the ulna then permitted full-field mechanical characterization of the ulna. The FEM was validated against a normal strain-gaged turkey ulna, loaded in vivo in an identical fashion to the experimental ulnae. Twenty-four candidate mechanical parameters were then compared to the quantified adaptive responses, using statistical techniques. The data supported strain energy density, longitudinal shear stress, and tensile principal stress/strain as the mechanical parameters most likely related to the initiation of the remodeling response. Model predictions can now suggest new experiments, against which the predictions can be supported or falsified.  相似文献   

16.
The ability to create extracellular matrix (ECM) constructs that are mechanically and biochemically similar to those found in vivo and to understand how their properties affect cellular responses will drive the next generation of tissue engineering strategies. To date, many mechanisms by which cells biochemically communicate with the ECM are known. However the mechanisms by which mechanical information is transmitted between cells and their ECM remain to be elucidated. "Self-assembled" collagen matrices provide an in vitro-model system to study the mechanical behavior of ECM. To begin to understand how the ECM and the cells interact mechanically, the three-dimensional (3D) mechanical properties of the ECM must be quantified at the micro-(local) level in addition to information measured at the macro-(global) level. Here we describe an incremental digital volume correlation (IDVC) algorithm to quantify large (>0.05) 3D mechanical strains in the microstructure of 3D collagen matrices in response to applied mechanical loads. Strain measurements from the IDVC algorithm rely on 3D confocal images acquired from collagen matrices under applied mechanical loads. The accuracy and the precision of the IDVC algorithm was verified by comparing both image volumes collected in succession when no deformation was applied to the ECM (zero strain) and image volumes to which simulated deformations were applied in both ID and 3D (simulated strains). Results indicate that the IDVC algorithm can accurately and precisely determine the 3D strain state inside largely deformed collagen ECMs. Finally, the usefulness of the algorithm was demonstrated by measuring the microlevel 3D strain response of a collagen ECM loaded in tension.  相似文献   

17.
Identification of functional programmable mechanical stimulation (PMS) on tendon not only provides the insight of the tendon homeostasis under physical/pathological condition, but also guides a better engineering strategy for tendon regeneration. The aims of the study are to design a bioreactor system with PMS to mimic the in vivo loading conditions, and to define the impact of different cyclic tensile strain on tendon. Rabbit Achilles tendons were loaded in the bioreactor with/without cyclic tensile loading (0.25 Hz for 8 h/day, 0–9% for 6 days). Tendons without loading lost its structure integrity as evidenced by disorientated collagen fiber, increased type III collagen expression, and increased cell apoptosis. Tendons with 3% of cyclic tensile loading had moderate matrix deterioration and elevated expression levels of MMP‐1, 3, and 12, whilst exceeded loading regime of 9% caused massive rupture of collagen bundle. However, 6% of cyclic tensile strain was able to maintain the structural integrity and cellular function. Our data indicated that an optimal PMS is required to maintain the tendon homeostasis and there is only a narrow range of tensile strain that can induce the anabolic action. The clinical impact of this study is that optimized eccentric training program is needed to achieve maximum beneficial effects on chronic tendinopathy management. Biotechnol. Bioeng. 2013; 110: 1495–1507. © 2012 Wiley Periodicals, Inc.  相似文献   

18.
Mechanical stimulation has been implicated as an important regulatory factor in tendon homeostasis. In this study, a custom-designed tensile loading system was used to apply controlled mechanical stimulation to isolated tendon fascicles, in order to examine the effects of 5% cyclic tensile strain at 1 Hz on cell proliferation and matrix synthesis. Sample viability and gross structural composition were maintained over a 24 h loading period. Data demonstrated no statistically significant differences in cell proliferation or glycosaminoglycan production, however, collagen synthesis was upregulated with the application of cyclic tensile strain over the 24 h period. Moreover, a greater proportion of the newly synthesised matrix was retained within the sample after loading. These data provide evidence of altered anabolic activity within tendon in response to mechanical stimuli, and suggest the importance of cyclic tensile loading for the maintenance of the collagen hierarchy within tendon.  相似文献   

19.
A knowledge of the mechanical processes triggered in the bone and periodontal ligament (PDL) by orthodontic forces applied to a tooth is of decisive importance for an understanding of the subsequent remodelling around the tooth. To investigate these mechanical relationships, three-dimensional finite element (FE) models of the first lower molar in the rat were established. On the basis of digitized serial histological sections, these FE models were generated semi-automatically. Using various simplified geometrical variations, an appropriate FE model for the analysis of the stress and strain distributions was established. The numerical analyses were carried out under a mesially directed force of 0.1 N. Stress distributions in the bone and PDL showed a similar pattern, while strains in the bone were lower than in the PDL by a factor of 10-5. The data confirm the assumption that strain patterns in the PDL may be the key stimulus of bone remodelling.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号