首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sensitive electrochemical immunosensor for the detection of protein biomarker tumor necrosis factor α (TNF-α) was reported that uses ferrocene carboxylic acid (Fc) functionalized self-assembled peptide nanowire (Fc-PNW) as sensor platform and glucose oxidase (GOx) modified gold nanorod (GNR) as label. Greatly enhanced sensitivity is achieved based on a dual signal amplification strategy: first, the synthesized Fc-PNW used as the sensor platform increased the loading of primary anti-TNF-α antibody (Ab(1)) onto electrode surface due to its large surface area. At the same time, the Fc moiety on the nanowire is used as a mediator for GOx to catalyze the glucose reaction. Second, multiple GOx and secondary anti-TNF-α antibody (Ab(2)) molecules are bounded onto each GNR to increase the sensitivity of the immunosensor. After the preparation of the immunosensor based on the traditional sandwich protocol, the response of the immunosensor towards glucose was used as a signal to differentiate various concentrations of TNF-α. The resulting immunosensor has high sensitivity, wide linear range (0.005-10ng/mL) and good selectivity. This immunosensor preparation strategy is a promising platform for clinical screening of protein biomarkers.  相似文献   

2.
A novel strategy for the fabrication of sensitive immunosensor to detect alpha-fetoprotein (AFP) in human serum has been proposed. The immunosensor was prepared by immobilizing AFP antigen onto the glassy carbon electrode (GC) modified by gold nanoparticles and carbon nanotubes doped chitosan (GNP/CNT/Ch) film. GNP/CNT hybrids were produced by one-step synthesis based on the direct redox reaction. The electrochemical properties of GNP/CNT/Ch films were characterized by impedance spectroscopy and cyclic voltammetry. It was indicated that GNP/CNT nanohybrid acted as an electron promoter and accelerated the electron transfer. Sample AFP, immobilized AFP, and alkaline phosphatase (ALP)-labeled antibody were incubated together for the determination based on a competitive immunoassay format. After the immunoassay reaction, the bound ALP label on the modified GC led to an amperometric response of 1-naphthyl phosphate (1-NP), which was changed with the different antigen concentrations in solution. Under the optimized experimental conditions, the resulting immunosensor could detect AFP in a linear range from 1 to 55 ng ml(-1) with a detection limit of 0.6 ng ml(-1). The proposed immunosensor, by using GNP/CNT/Ch as the immobilization matrix of AFP, offers an excellent amperometric response of ALP-anti-AFP to 1-NP. The immunosensor provided a new alternative to the application of other antigens or other bioactive molecules.  相似文献   

3.
A novel potentiometric immunosensor for the detection of hepatitis B surface antigen has been developed by means of self-assembly to immobilize hepatitis B surface antibody on a platinum disk electrode based on gold nanoparticles, Nafion, and gelatin as matrices in this study. The modification procedure of the immunosensor was further characterized by using cyclic voltammetry and the enzyme-linked immunosorbent assay (ELISA) method. The detection is based on the change in the electric potential before and after the antigen-antibody reaction. In contrast to the commonly applied methods (e.g., the glutaraldehyde crosslinking procedure), this strategy could allow for antibodies immobilized with a higher loading amount and better retained immunoactivity, as demonstrated by the potentiometric measurements. A dynamic concentration range of 4-800 ng ml(-1) and a detection limit of 1.3 ng ml(-1) were observed. Analytical results of several human serum samples obtained using the developing technique are in satisfactory agreement with those given by ELISA. In addition, the technique presents some distinct advantages over the traditional sandwich format in that the analyzing performances are direct, rapid, and simple without multiple separation and labeling steps.  相似文献   

4.
A sensitive electrochemical immunosensor with graphene-assisted signal amplification has been developed. In order to construct the base of the immunosensor, a novel hybrid architecture was initially fabricated by combining poly (diallyldimethylammonium chloride) functionalized graphene nanosheets (PDDA-G) and gold nanoparticles (AuNPs) via a simple sonication-induced assembly. The formed hybrid architecture provided an effective matrix for antibody immobilization with good stability and bioactivity. Subsequently, a smart, multilabel, and graphene-based nanoprobe that contains gold nanoparticles functionalized exfoliated graphene oxide and horseradish peroxidase-secondary antibodies was designed for constructing a novel sandwiched electrochemical immunosensor. Enhanced sensitivity was obtained by combining the advantages of high-binding capability and excellent electrical conductivity of hybrid architecture with the multilabel signal amplification. On the basis of the dual signal amplification strategy of graphene-based architecture and the multilabel, the immunosensor displayed excellent analytical performance for the detection of human IgG (HIgG) range from 0.1 to 200 ng/mL with a detection limit of 0.05 ng/mL at 3σ. Moreover, the proposed method showed good precision, acceptable stability and reproducibility, and could be used for the detection of HIgG in real samples. Therefore, the present strategy definitely paves a way for the wide application of graphene in clinical research.  相似文献   

5.
An enzyme-free amperometric method was established for glucose detection using a nanoporous gold film (NPGF) electrode prepared by a rapid one-step anodic potential step method within 5 min. The prepared NPGF had an extremely high roughness and was characterized by scanning electron microscopy (SEM) and cyclic voltammetry. Electrochemical responses of the as-prepared NPGF to glucose in 0.1M phosphate buffer solution (PBS, pH 7.4) with or without Cl(-) were discussed. In amperometric studies carried out at -0.15 V in the absence of Cl(-), the NPGF electrode exhibited a high sensitivity of 232 μA mM(-1)cm(-2) and gave a linear range from 1mM up to 14 mM with a detection limit of 53.2 μM (with a signal-to-noise ratio of 3). In addition, the oxidation of ascorbic acid (AA) and uric acid (UA) can be completely eliminated at such a low applied potential. On the other hand, the quantification of glucose in 0.1M PBS (pH 7.4) containing 0.1M NaCl offered an extended linear range from 10 μM to 11 mM with a sensitivity of 66.0 μA mM(-1)cm(-2) and a low detection limit of 8.7 μM (signal-to-noise ratio of 3) at a detection potential of 0.2V.  相似文献   

6.
A new current amplified immunosensor for the determination of carcinoembryonic antigen (CEA) was demonstrated in this work. The electrode architecture was fabricated by positively charged toluidine blue (TB) coated on negatively charged poly-sulfanilic acid (PSAA) modified glassy carbon electrode (GCE) surface through electrostatic interactions to form a TB/PSAA film, which provided an interface containing amine groups to assemble gold nanoparticles (nano-Au) for immobilization of carcinoembryonic antibody (anti-CEA) and horseradish peroxidase (HRP) instead of bovine serum albumin (BSA) to block sites against non-specific binding. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed to characterize the electrochemical properties of the modified processes. The CVs reduction current of the immunosensor charged linearly in two concentration ranges of CEA from 0.5 to 5.0 and 5.0 to 120.0 ng/ml in presence of 0.3mM H2O2 in analyte solution, and the detection limit was 0.2 ng/ml at three times background noise. The proposed method is economical, efficient and potentially attractive for clinical immunoassays.  相似文献   

7.
A label-free electrochemical immunoassay for neuron-specific enolase (NSE), a kind of lung cancer marker, was developed in this work via novel electrochemical catalysis for signal amplification. The new amplified strategy was based on the electrochemical catalysis of nickel hexacyanoferrates nanoparticles (NiHCFNPs) in the presence of dopamine (DA). NiHCFNPs, which were assembled on the porous gold nanocrystals (AuNCs) modified glassy carbon electrode (GCE), could exhibit a distinct pair of redox peaks corresponding to anodic and cathodic reactions of hexacyanoferrate (II/III). Subsequently, gold nanoparticles functionalized graphene nanosheets (Au-Gra) were coated on the surface of NiHCFNPs/AuNCs film. Then an enhanced amount of neuron-specific enolase antibody (anti-NSE) could be loaded to obtain a sensitive immunosensor of anti-NSE/Au-Gra/NiHCFNPs/AuNCs/GCE due to the strong adsorption capacity and large specific surface area of Au-Gra. More importantly, the oxidation peak current can be enormously enhanced towards the electrocatalytic oxidation of DA based on NiHCFNPs, resulting in the further improvement of the immunosensor sensitivity. Under optimal conditions, the electrochemical immunosensor exhibited a linear range of 0.001-100 ng/mL with a detection limit of 0.3 pg/mL (S/N=3). Thus, the proposed immunosensor provides a rapid, simple, and sensitive immunoassay protocol for NSE detection, which may hold a promise for clinical diagnosis.  相似文献   

8.
In this work, the direct electrochemical determination of poly-histidine tagged proteins using immunosensor based on anti-His (C-term) antibody immobilized on gold electrodes modified with 1,6-hexanedithiol, gold colloid particles or gold nanorods is described. The recombinant histidine-tagged silk proteinase inhibitor protein (rSPI2-His(6)) expressed in Pichia system selected as antigen for this immonosensor. An electrochemical impedance spectroscopy was used as label free detection technique for immune conjugation. The gold nanorods modified electrode layer showed better analytical response than gold nano particles. The linear calibration range was observed between 10pg/ml and 1ng/ml with limit of detection 5pg/ml (S/N=3). Up to four successive assay cycles with retentive sensitivity were achieved for the immunosensors regenerated with 0.2M glycine-HCl buffer, pH 2.8. The performance of this immnosensor were compared with immuoblotting techniques.  相似文献   

9.
A novel experimental methodology for studying a mediatorless and label-free immunosensor is proposed by immobilizing antibody on gold nanoparticle/L-cysteine coated electrode (nano-Au/L-cysteine electrode). Differential pulse voltammograms (DPV) resulting from the assembled immunosensor indicate that the immunosensor shows excellent electrochemical response to dopamine so that the electrochemical response is utilized for the signal generation step of the immunosensor. Therefore, by means of unenzymatic-labeling procedure combined with the amperometric detection using dopamine as substrate, the immunological reaction can be detected. After the immunosensor is incubated with h-IgG solution, the access of electrocatalytic behavior center of the immunosensor to dopamine is partly inhibited, which leads to a linear decrease in amperometric response of the immunosensor with h-IgG concentration over a range 0.82-90 ng mL(-1) by DPV.  相似文献   

10.
One-step construction of Pt nanoparticles-chitosan composite film (PtNPs-CS) was firstly proposed as a novel immobilization matrix for the enzymes to fabricate glucose biosensor. This novel interface embedded in situ PtNPs in CS hydrogel was developed by one-step electrochemical deposition in solution containing CS and chloroplatinic acid (H(2)PtCl(6)). Several techniques, including scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry were employed to characterize the assembly process and performance of the biosensor. Under the optimized experimental conditions, the resulting biosensor exhibited excellent linear behavior in the concentration range from 1.2 μM to 4.0 mM for the quantitative analysis of glucose with a limit of detection of 0.4 μM at a signal-to-noise ratio of 3. The apparent Michaelis-Menten constant (K(M)(app)) was evaluated to be 2.4 mM, showing good affinity. The proposed biosensor offered good amperometric responses to glucose due to the nanostructured sensing film provided plenty of active sites for the immobilization of glucose oxidase (GOD).  相似文献   

11.
The direct electrochemistry of glucose oxidase (GOD) adsorbed on a colloidal gold modified carbon paste electrode was investigated. The adsorbed GOD displayed a pair of redox peaks with a formal potential of -(449+/-1) mV in 0.1 M pH 5.0 phosphate buffer solution. The response showed a surface-controlled electrode process with an electron transfer rate constant of (38.9+/-5.3)/s determined in the scan rate range from 10 to 100 mV/s. GOD adsorbed on gold colloid nanoparticles maintained its bioactivity and stability. The immobilized GOD could electrocatalyze the reduction of dissolved oxygen and resulted in a great increase of the reduction peak current. Upon the addition of glucose, the reduction peak current decreased, which could be used for glucose detection with a high sensitivity (8.4 microA/mM), a linear range from 0.04 to 0.28 mM and a detection limit of 0.01 mM at a signal-to-noise ratio of 3sigma. The sensor could exclude the interference of commonly coexisted uric and ascorbic acid.  相似文献   

12.
Reduced graphene oxide/PAMAM-silver nanoparticles nanocomposite (RGO-PAMAM-Ag) was synthesized by self-assembly of carboxyl-terminated PAMAM dendrimer (PAMAM-G3.5) on graphene oxide (GO) as growing template, and in-situ reduction of both AgNO(3) and GO under microwave irradiation. The RGO-PAMAM-Ag nanocomposite was used as a novel immobilization matrix for glucose oxidase (GOD) and exhibited excellent direct electron transfer properties for GOD with the rate constant (K(s)) of 8.59 s(-1). The fabricated glucose biosensor based on GOD electrode modified with RGO-PAMAM-Ag nanocomposite displayed satisfactory analytical performance including high sensitivity (75.72 μA mM(-1) cm(-2)), low detection limit (4.5 μM), an acceptable linear range from 0.032 mM to 1.89 mM, and also preventing the interference of some interfering species usually coexisting with glucose in human blood at the work potential of -0.25 V. These results indicated that RGO-PAMAM-Ag nanocomposite is a promising candidate material for high-performance glucose biosensors.  相似文献   

13.
A sensitive amperometric immunosensor for carcinoembryonic antigen (CEA) was prepared. Firstly, a porous nano-structure gold (NG) film was formed on glassy carbon electrode (GCE) by electrochemical reduction of HAuCl4 solution, then nano-Au/Chit composite was immobilized onto the electrode because of its excellent membrane-forming ability, and finally the anti-CEA was adsorbed onto the surface of the bilayer gold nanoparticles to construct an anti-CEA/nano-Au/Chit/NG/GCE immunosensor. The characteristics of the modified electrode at different stages of modification were studied by cyclic voltammetry (CV). The gold colloid, chitosan and nano-Au/Chit were characterized by transmission electron microscopy and UV–vis spectroscopy. In addition, the performances of the immunosensor were studied in detail. The resulting immunosensor offers a high-sensitivity (1310 nA/ng/ml) for the detection of CEA and has good correlation for detection of CEA in the range of 0.2 to 120.0 ng/ml with a detection limit of 0.06 ng/ml estimated at a signal-to-noise ratio of 3. The proposed method can detect the CEA through one-step immunoassay and would be valuable for clinical immunoassay.  相似文献   

14.
Glucose oxidase was embedded in organic films through a layer-by-layer approach, where the enzyme demonstrated significantly enhanced electron-transfer reactivity and finely tuned enzymatic activity. An unmediated, reagentless glucose biosensor was accordingly prepared with two polyethylenimine/glucose oxidase bilayers-modified pyrolytic graphite electrode. A calibration linear range of glucose was 0.5-8.9 mM with a detection limit of 50 microM and sensitivity of 0.76 microA mM(-1).  相似文献   

15.
A novel label free electrochemiluminescence (ECL) immunosensor based on the ECL of peroxydisulfate solution for detection of α-1-fetoprotein (AFP) has been developed. For this proposed immunosensor, L-cysteine was firstly electrodeposited on the gold electrode surface, which promoted the electron transfer and largely enhanced the ECL of peroxydisulfate solution. Subsequently, gold nanoparticles (nano-Au) were assembled onto the L-cysteine film modified electrode to improve the absorption capacity of antibody and further amplify the ECL signal. Then, antibody was immobilized onto the electrode through nano-Au. At last bovine serum albumin (BSA) was employed to block the nonspecific binding sites. As a result, a novel ECL immunosensor was firstly obtained by applying the ECL of peroxydisulfate solution without conventional luminescent reagents. The AFP was determined in the range of 0.01-100 ng mL(-1), with a low detection limit of 3.3 pg mL(-1) (S/N=3). The proposed ECL immunosensor provides a rapid, simple, and sensitive immunoassay protocol for protein detection, which might hold a promise for clinical application. Moreover, this work would open up a new field in the application of peroxydisulfate solution ECL for highly sensitive bioassays.  相似文献   

16.
Development of an electrochemical immunosensor for alanine aminotransferase   总被引:1,自引:0,他引:1  
Alanine aminotransferase (ALT) has been regarded as one of the most sensitive indicators of hepatocellular damage. While ALT is widely used in the practice of medicine, few attempts have been made to develop biosensors applicable to the on-site diagnosis of liver diseases. In the hope of developing an immunosensor for measurement of ALT activity, we have generated monoclonal antibodies to human recombinant ALT and fabricated them for use in a sensor. The ALT immunosensor was composed of the followings: (1) anti-ALT antibody-immobilized outer membrane; (2) pyruvate oxidase-absorbed inner membrane; (3) a self assembled monolayer mediator-coated gold working electrode and an Ag/AgCl reference electrode. The chronoamperometric measurement of the immunosensor was performed with 40 microl of PBS containing substrates and ALT without a washing step in less than 5 min. The dynamic range of ALT immunosensor was presented as five orders of magnitude, ranging between 10 pg/ml and 1 microg/ml. The detection limit and the sensitivity were 10 pg/ml and 26.3 nA/(ng/ml), respectively. In the meantime, the enzyme sensor fabricated without anti-ALT antibody showed much poorer analytical values. The dynamic range, the detection limit, and the sensitivity were 10 ng/ml-100 microg/ml, 10 ng/ml and 11.4 nA/(ng/ml), respectively. The presented results indicated that the immunosensor system provided much better technical performance in all of the aspects evaluated than did the enzyme sensor without the immobilized-antibody.  相似文献   

17.
A simple, fast, green and controllable approach was developed for electrochemical synthesis of a novel nanocomposite of electrochemically reduced graphene oxide (ERGO) and gold-palladium (1:1) bimetallic nanoparticles (AuPdNPs), without the aid of any reducing reagent. The electrochemical reduction efficiently removed oxygen-containing groups in ERGO, which was then modified with homogeneously dispersed AuPdNPs in a good size distribution. ERGO-AuPdNPs nanocomposite showed excellent biocompatibility, enhanced electron transfer kinetics and large electroactive surface area, and were highly sensitive and stable towards oxygen reduction. A biosensor was constructed by immobilizing glucose oxidase as a model enzyme on the nanocomposites for glucose detection through oxygen consumption during the enzymatic reaction. The biosensor had a detection limit of 6.9μM, a linear range up to 3.5mM and a sensitivity of 266.6μAmM(-1)cm(-2). It exhibited acceptable reproducibility and good accuracy with negligible interferences from common oxidizable interfering species. These characteristics make ERGO-AuPdNPs nanocomposite highly suitable for oxidase-based biosensing.  相似文献   

18.
By a dealloying/annealing/redealloying strategy, nanoporous gold (NPG) with hierarchical microstructure is fabricated for electrochemical biosensing application. The first dealloying and annealing would produce NPG/AuAg alloy composite with a large-pore NPG layer and the second dealloying would further etch the AuAg alloy part in the composite, generating a small-pore NPG layer. By using the large-pore (≈ 100 nm) layer as the glucose oxidase (GOx) container, and the small-pore (≈ 12 nm) layer as a signal producer, this novel hierarchical NPG is demonstrated to be a good support for enzyme immobilization and fabricating enzyme-based biosensors. The immobilized GOx retains ≈ 92% of the initial activity after 7 repeated use. The GOx-loaded stratified NPG biosensor can detect glucose more sensitively with a wider linear range (up to 22 mM) than normal NPG with a uniform pore size of 30-40 nm (linear range: up to 17 mM).  相似文献   

19.
A novel immunosensor based on a multilayer-coated glassy carbon electrode was designed to determine isopentenyl adenosine (iPA) in plants. The multilayer consists of polypyrrole and poly(m-phenylenediamine) with K4Fe(CN)6 and horseradish peroxidase (HRP) entrapped during electropolymerization. The ferrocyanide doped in polypyrrole functions as the mediator. The glucose oxidase bound on the immunosensor by the competitive immunoreaction involving iPA catalyzed the oxidation of the added glucose with the formation of H2O2, which is in turn reduced in the presence of HRP entrapped in poly(m-phenylenediamine). The current of the oxidized production of ferrocyanide reduced at -50 mV is inversely proportional to the concentration of iPA in the competitive immunoreaction. This immunosensor is able to be used about 40 times; after that its surface can be regenerated for a new immunosensor assembly by washing with 0.1M citrate-phosphate buffer (pH 4.6). The percentage of current response reduction (CR%) (y) is linearly related to the logarithm of the concentration of iPA (x) in the 5-300 microg/ml range, with a regression equation of the form y = 42.13x - 27.79 and a correlation coefficient of 0.9861. Five hybrid rice grain samples were analyzed with results in satisfactory agreement to those obtained by high-performance liquid chromatography.  相似文献   

20.
In this article, a novel, label-free, and inherent electroactive redox immunosensor for carcinoembryonic antigen (CEA) based on gold nanoparticles (AuNPs) and Nile blue A (NB) hybridized electrochemically reduced graphene oxide (NB–ERGO) is proposed. The composite of NB–graphene oxide (NB–GO) was prepared by π–π stacking interaction. Then, chronoamperometry was adopted to simultaneously reduce HAuCl4 and nanocomposites of NB–GO for synthesizing AuNPs/NB–ERGO. The immunosensor was fabricated by capturing CEA antibody (anti-CEA) at this nanocomposite modified electrode. The immunosensor determination was based on the fact that, due to the formation of antigen–antibody immunocomplex, the decreased response currents of NB were directly proportional to the concentrations of CEA. Under optimal conditions, the linear range of the proposed immunosensor was estimated to be from 0.001 to 40 ng ml−1 and the detection limit was estimated to be 0.00045 ng ml−1. The proposed immunosensor was used to determine CEA in clinical serum samples with satisfactory results. The proposed method may provide promising potential application in clinical immunoassays with the properties of facile procedure, stability, high sensitivity, and selectivity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号