首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
The increasing concern with bioaerosols in large office buildings prompted this prospective study of airborne fungal concentrations in a newly constructed building on the Gulf coast. We collected volumetric culture plate air samples on 14 occasions over the 18-month period immediately following building occupancy. On each sampling occasion, we collected duplicate samples from three sites on three floors of this six-story building, and an outdoor sample. Fungal concentrations indoors were consistently below those outdoors, and no sample clearly indicated fungal contamination in the building, although visible growth appeared in the ventilation system during the course of the study. We conclude that modern mechanically ventilated buildings prevent the intrusion of most of the outdoor fungal aerosol, and that even relatively extensive air sampling protocols may not sufficiently document the microbial status of buildings. Received: 7 April 1999 / Accepted: 2 August 1999  相似文献   

2.
About 25% of European livestock intake is based on permanent and sown grasslands. To fulfill rising demand for animal products, an intensification of livestock production may lead to an increased consumption of crop and compound feeds. In order to preserve an economically and environmentally sustainable agriculture, a more forage based livestock alimentation may be an advantage. However, besides management, grassland productivity is highly vulnerable to climate (i.e., temperature, precipitation, CO2 concentration), and spatial information about European grassland productivity in response to climate change is scarce. The process-based vegetation model ORCHIDEE-GM, containing an explicit representation of grassland management (i.e., herbage mowing and grazing), is used here to estimate changes in potential productivity and potential grass-fed ruminant livestock density across European grasslands over the period 1961–2010. Here “potential grass-fed ruminant livestock density” denotes the maximum density of livestock that can be supported by grassland productivity in each 25 km × 25 km grid cell. In reality, livestock density could be higher than potential (e.g., if additional feed is supplied to animals) or lower (e.g., in response to economic factors, pedo-climatic and biotic conditions ignored by the model, or policy decisions that can for instance reduce livestock numbers). When compared to agricultural statistics (Eurostat and FAOstat), ORCHIDEE-GM gave a good reproduction of the regional gradients of annual grassland productivity and ruminant livestock density. The model however tends to systematically overestimate the absolute values of productivity in most regions, suggesting that most grid cells remain below their potential grassland productivity due to possible nutrient and biotic limitations on plant growth. When ORCHIDEE-GM was run for the period 1961–2010 with variable climate and rising CO2, an increase of potential annual production (over 3%) per decade was found: 97% of this increase was attributed to the rise in CO2, -3% to climate trends and 15% to trends in nitrogen fertilization and deposition. When compared with statistical data, ORCHIDEE-GM captures well the observed phase of climate-driven interannual variability in grassland production well, whereas the magnitude of the interannual variability in modeled productivity is larger than the statistical data. Regional grass-fed livestock numbers can be reproduced by ORCHIDEE-GM based on its simple assumptions and parameterization about productivity being the only limiting factor to define the sustainable number of animals per unit area. Causes for regional model-data misfits are discussed, including uncertainties in farming practices (e.g., nitrogen fertilizer application, and mowing and grazing intensity) and in ruminant diet composition, as well as uncertainties in the statistical data and in model parameter values.  相似文献   

3.
4.
Culicoides biting midges (Diptera: Ceratopogonidae) serve as biological vectors for several pathogens, including the Bluetongue virus and the recently described Schmallenberg virus in northern Europe. These diseases have caused considerable direct and indirect economic losses to the sheep and cattle industries. This study undertaken between August and December 2007 on a sheep farm in the Namur province (Belgium) aims to evaluate Culicoides populations present inside a partially opened sheepfold and in a nearby sheep meadow, using light traps. The comparative analysis of insects trapped at 18 dates at regular intervals showed that Culicoides were most abundant inside this livestock building (17,450 midges) than in surrounding meadow (1,121 midges); this meadow had however a greater species diversity. The two species C. obsoletus and C. scoticus constituting the Obsoletus complex predominated for all trappings and females were much more numerous than males. Important capture of engorged females of the Obsoletus complex inside the sheepfold seems to reflect the possibility of an opportunistic endophagous behavior. Maintaining sheep inside livestock buildings in order to reduce the risk of Culicoides bites – and thus of pathogens transmission – however requires to limit biting midge populations which are likely to enter or to develop inside these buildings. Implementation of effective sanitation and hygiene measures against midges present inside farms, as well as establishing of measures to protect livestock against intrusion and improvement of “midge-proofing” of animal housing are therefore highly recommended.  相似文献   

5.
The indoor air quality (IAQ) in classrooms highly affects the health and productivity of students. This article aims to clarify seasonal variation in indoor environment and sick building syndromes (SBS) symptoms in an Eastern Mediterranean climate. A series of field measurements were conducted during the fall and winter seasons from October 2011 to March 2012 in 12 naturally ventilated schools located in the Gaza Strip. Data on environmental perception and health symptoms were obtained from 724 students by using a validated questionnaire. The results showed that indoor PM10 and PM2.5 concentrations were 426.3 ± 187.6 μg/m3 and 126.6 ± 94.8 μg/m3, respectively. The CO2 concentrations and ventilation rate widely exceeded their reference values during the winter season. The prevalence rates of general symptoms were relatively high at baseline assessment in the fall season and increased significantly during follow-up in the winter season. Significant increases in disease symptoms such as mucosal irritation and pre-existing asthma symptoms among students could be related to poor indoor air quality. Five distinct groups of SBS symptoms from factor analysis of students’ related symptoms were significantly correlated with PM10 and PM2.5, CO2, ventilation rate, and indoor temperature. As vulnerable children, this situation negatively affects their school performance and health.  相似文献   

6.
Providing sufficient amounts of outdoor air to occupants is a critical building function for supporting occupant health, well-being and productivity. In tropical climates, high ventilation rates require substantial amounts of energy to cool and dehumidify supply air. This study evaluates the energy consumption and associated cost for thermally conditioning outdoor air provided for building ventilation in tropical climates, considering Singapore as an example locale. We investigated the influence on energy consumption and cost of the following factors: outdoor air temperature and humidity, ventilation rate (L/s per person), indoor air temperature and humidity, air conditioning system coefficient of performance (COP), and cost of electricity. Results show that dehumidification of outdoor air accounts for more than 80% of the energy needed for building ventilation in Singapore’s tropical climate. Improved system performance and/or a small increase in the indoor temperature set point would permit relatively large ventilation rates (such as 25 L/s per person) at modest or no cost increment. Overall, even in a thermally demanding tropical climate, the energy cost associated with increasing ventilation rate up to 25 L/s per person is less than 1% of the wages of an office worker in an advanced economy like Singapore’s. This result implies that the benefits of increasing outdoor air ventilation rate up to 25 L/s per person — which is suggested to provide for productivity increases, lower sick building syndrome symptom prevalence, and reduced sick leave — can be much larger than the incremental cost of ventilation.  相似文献   

7.
Given the growing concerns over human and animal health issues related to confined animal feeding operations, an in‐depth examination is required to monitor for airborne bacteria and associated antibiotic resistance genes. Our 16S rRNA‐based pyrosequencing revealed that the airborne microbial community skewed towards a higher abundance of Firmicutes (> 59.2%) and Bacteroidetes (4.2–31.4%) within the confinement buildings, while the office environment was predominated by Proteobacteria (55.2%). Furthermore, bioaerosols in the confinement buildings were sporadically associated with genera of potential pathogens, and these genera were more frequently observed in the bioaerosols of pig and layer hen confinement than the turkey confinement buildings and office environment. High abundances of tetracycline resistance genes (9.55 × 102 to 1.69 × 106 copies ng?1 DNA) were also detected in the bioaerosols sampled from confinement buildings. Bacterial lineages present in the poultry bioaerosols clustered apart from those present in the pig bioaerosols and among the different phases of pig production, suggesting that different livestock as well as production phase were associated with a distinct airborne microbial community. By understanding the diversity of biotic contaminants associated with the different confinement buildings, this study facilitates the implementation of better management strategies to minimize potential health impacts on both livestock and humans working in this environment.  相似文献   

8.
One of the key factors to improve swine production sustainability is the use of agro-industrial by-products in feeds, such as olive by-products. However, it is necessary to assess its effects on the overall production process, including the animal and the environment. With this aim, an experiment was conducted to determine the effects of including a partially defatted olive cake (PDOC) in pig diets on growth performance, faecal microbiota, carcass quality and gas emission from the slurry. Two finishing diets were formulated, a control (C) diet and a diet with PDOC included at 120 g/kg. Eighty finishing male pigs Duroc-Danbred × (Landrace × Large White) of 60.4 ± 7.00 kg BW were divided between these two treatments. During the finishing period (60 to 110 kg BW, 55 days) average daily gain, average daily feed intake and feed conversion ratio were recorded. Faecal samples from the rectum of 16 animals per treatment were incubated for bacteria enumeration. At the end of finishing period, backfat thickness and loin depth (LD) were measured. Animals were slaughtered to obtain carcass weight and carcass composition parameters, and subcutaneous fat was sampled to analyse the fatty acid (FA) profile. In addition greenhouse gas and ammonia emissions were measured during pig slurry storage using the methodology of dynamic flux chambers. An initial slurry characterisation and biochemical methane potential (B0) were also determined. No significant differences between treatments were found in performance, carcass quality and microbial counts with the exception of LD, which was lower in PDOC compared with C animals (45.5 v. 47.5 mm, SEM: 0.62; P = 0.020). The FA profile of the subcutaneous fat did not differ between treatments, but the monounsaturated FA (MUFA) concentration was higher and the polyunsaturated FA was lower in the animals fed PDOC (50.9 v. 48.3, SEM: 0.48, P < 0.001; 17.6 v. 19.3, SEM: 0.30, P < 0.001 in mg/100 g of Total FA, for PDOC and C animals, respectively). The initial pig slurry characterisation only showed differences in ADF concentration that was higher (P < 0.05) in the slurry from PDOC treatment. Regarding gas emission, slurries from both treatments emitted similar amounts of ammonia (NH3), carbon dioxide (CO2), methane (CH4) and nitrous oxide (N2O), as well as B0 values. The results obtained suggest that PDOC may be included in balanced pig diets at rates of up to 120 g/kg without negative effects on performance, carcass quality, gut microflora and slurry gas emission, while improving the MUFA concentration of subcutaneous fat.  相似文献   

9.
Many studies have focused on the sources of fungal contamination in indoor spaces. Pathogenic fungi have been detected in the potting mix of indoor plants; however, it is unclear if plants in indoor work spaces make qualitative or quantitative contributions to the aeromycota within buildings. The current work represents a field study to determine, under realistic office conditions, whether indoor plants make a contribution to the airborne aeromycota. Fifty-five offices, within two buildings in Sydney’s central business district, were studied over two seasonal periods: autumn and spring. We found that indoor plant presence made no significant difference to either indoor mould spore counts or their species composition. No seasonal differences occurred between autumn and spring samples. Indoor spore loads were significantly lower than outdoor levels, demonstrating the efficiency of the heating, ventilation and air conditioning systems in the buildings sampled. Neither the number of plants nor the species of plant used had an influence on spore loads; however, variations of those two variables offer potential for further studies. We conclude that conservative numbers of indoor plants make no substantial contribution to building occupants exposure to fungi.  相似文献   

10.
Although isolation racks are superior to open-type racks in terms of securing breeding conditions for laboratory animals, the contingency-proofing capability of the former has yet to be determined. Therefore, from the view of risk management, we studied the environmental change in isolation racks by forcibly suspending ventilation and air-conditioning and confirming the maximal time length for complete recovery to the original condition after restarting their operations. The isolation racks were placed in a room that was equipped with an independent air-conditioning system. When the inside condition of the racks reached 22-24 degrees C and 59-64% of relative humidity, the air-conditioning and ventilation were forcibly suspended and the subsequent temperature, relative humidity, ammonium and CO2 concentrations in the racks were measured over time. We found that after suspending the air-conditioning and ventilation, it took 40-60 min for temperature, and about 10 min for relative humidity to exceed the maximum values (temperature and relative humidity) referred to in the Showa 58 Nenban Guideline Jikken Doubutsu Shisetsu no Kenchiku oyobi Setsubi (Guidelines of buildings and facilities for experimental animals in Japan; Year 1983 edition). After 17 hr 25 min of the suspension of air-conditioning and ventilation, two rats were found dead. Then, the air-conditioning and ventilation were restarted. It took about 2 hr for temperature, and 50 min for relative humidity to regain the guideline values. The ammonium concentration stayed within the guideline value with a maximum concentration of 2 ppm in the experimental period, whereas the CO2 concentration was found to exceed 9% at the time of animal death.  相似文献   

11.

Purpose

Life cycle assessment (LCA) has largely focused on characterizing the impact of outdoor emissions. However, the intake fraction (iF) of indoor air emissions could be more important. The present paper aims to determine the long-term intake fractions of indoor emissions, including multiple indoor removal pathways such as sorption on indoor surfaces, and to compare it to the outdoor intake fraction.

Method

The developed model accounts for the different removal pathways in buildings, including air exchange, degradation in the gas phase, degradation on surfaces, and finally partitioning between air, walls, and furniture assuming a kinetically limited material transfer between gas phase and a near-surface film. The indoor intake fraction is presented as a function of the adsorption and degradation rate on surfaces.

Results and discussion

The intake fraction of volatile substances is only affected by the ventilation rate, with a constant intake fraction of 1?×?10?2. For ozone-sensitive substances, indoor gas phase reactions can significantly reduce the intake fraction. Semi-volatile substances are affected by the adsorption and degradation on room surfaces. For highly adsorbing substances, the decrease in intake fraction is limited to a minimum value of 2.5?×?10?4 by the mass transfer rate between air and room surfaces for a typical office or residence room in developed countries with temperate climate. Indoor intake fraction is compared to outdoor intake fraction calculated using the Impact 2002 multimedia model. Typical calculated indoor intake fraction values are in a significantly higher range (2.5?×?10?4 to 1?×?10?2) than inhalation outdoor values (1?×?10?9 to 1?×?10?6).

Conclusions

This paper opens new possibilities to assess the health impact of indoor and outdoor air emissions in a consistent way, including surface sorption??a major removal pathway for semi-volatile compounds. By combining the newly calculated intake fractions with effect factors and with indoor and outdoor emissions per functional unit, it becomes possible to consistently account for indoor exposure in methods such as LCA  相似文献   

12.
Feed trials were carried out to assess the influence of crude protein content in finishing pig diets on odour and ammonia emissions. Eight pigs (4 boars and 4 gilts), average initial weight 70.8 kg (s.e. 3.167) were housed in two pens that were isolated from the rest of a pig house at University College Dublin Research Farm, Newcastle, Dublin, Ireland. Four diets containing 130, 160, 190 and 220 g x kg(-1) crude protein were fed during six four-week feeding periods (one treatment per room). The first week of the feeding periods served to allow odour build up in the pens and as a dietary adjustment period. The pens had partially slatted floors that were cleaned and had all the manure removed after each four-week period. Odour and ammonia concentrations were measured on days 9, 14, 16, 21 and 23 of each trial period. Odour samples were collected in Nalophan bags and analysed for odour concentration using an ECOMA Yes/No olfactometer. The odour threshold concentration was calculated according to the response of the olfactometry panel members and was displayed in Ou(E)m(-3), which referred to the physiological response from the panel equivalent to that elicited by 40 ppbv(-1) n-butanol evaporated in 1 m(3) of neutral gas. Ammonia concentrations in the ventilation air were measured using Dr?ger tubes. The odour emission rates per animal for the 130, 160, 190 and 220 g x kg(-1) crude protein diets were 12.1, 13.2, 19.6 and 17.6 Ou(E)s(-1)animal(-1), respectively (P<0.01). The odour emission rate per livestock unit (500 kg) for the 130, 160, 190 and 220 g x kg(-1) crude protein diets were 77.6, 80.0, 115.8 and 102.9 Ou(E)s(-1)LU(-1), respectively (P<0.01). The ammonia emission rates per animal for the 130, 160, 190 and 220 g x kg(-1) crude protein diets were 3.11, 3.89, 5.89 and 8.27 g x d(-1)animal(-1), respectively (P0.05). Manipulation of dietary crude protein levels would appear to offer a low cost alternative, in relation to end-of-pipe treatments, for the abatement of odour and ammonia emissions from finishing pig houses.  相似文献   

13.
Three days after subcutaneous injection of N-nitroso-N-methylurethane (NNNMU) to induce lung injury, adult rabbits were mechanically ventilated and lung function was evaluated. Each animal then received either nebulized Survanta (Neb Surv), nebulized saline (Neb Saline), nebulized gas alone (Neb Gas), or tracheally instilled Survanta (Inst Surv). The ventilation efficiency index (VEI) value increased significantly compared with pretreatment values (P less than 0.01) over a 3-h treatment period for the Neb Surv animals, whereas VEI values for the other three groups decreased after treatment (P less than 0.05). Arterial PO2-to-fraction of inspired O2 ratios and dynamic compliance values significantly decreased after treatment for the Inst Surv group (P less than 0.05). Pressure-volume curves demonstrated a significantly greater volume at maximal pressure for the Neb Surv group compared with each of the other groups studied (P less than 0.01). The calculated quantity of surfactant recovered in lung tissue for the Neb Surv group was only 4.9 +/- 1.0 mg lipid/kg compared with 100 mg lipid/kg delivered to the Inst Surv group. Surfactant administered as an aerosol resulted in modest physiological improvements in this model of lung injury and was superior to the tracheal instillation technique.  相似文献   

14.
The purpose of this study was: (i) to characterize the school indoor environment; (ii) to evaluate self-reported prevalence of disease symptoms among Portuguese teachers; and (iii) to evaluate, as far as we know for the first time in Portugal, the impact of the indoor air quality of schools on the prevalence of disease symptoms among teachers. The study was performed in the city of Oporto, starting in 2004; it included the analysis of questionnaires fulfilled by schoolteachers (n = 177), walkthrough surveys of schools grounds, buildings, and individual classrooms (n = 76), as well as indoor air monitoring. Respirable particle increase was related to chalk use and CO2 concentrations widely exceeded reference values. Schools located near traffic lines presented higher benzene and toluene concentrations. The guideline for total viable microorganism concentration was exceeded in 35.6% of classrooms. Significant increases in disease symptoms among teachers could be related to poor indoor air quality, which was mainly due to inefficient ventilation and influence of traffic emissions. Statistically significant correlations were found between central nervous system injuries and the levels of CO2 and total volatile organic compounds, and between upper respiratory problems and mucosal irritation and the levels of TVOC and respirable particles.  相似文献   

15.
Livestock, particularly ruminants, can eat a wider range of biomass than humans. In the drive for greater efficiency, intensive systems of livestock production have evolved to compete with humans for high-energy crops such as cereals. Feeds consumed by livestock were analysed in terms of the quantities used and efficiency of conversion of grassland, human-edible ('edible') crops and crop by-products into milk, meat and eggs, using the United Kingdom as an example of a developed livestock industry. Some 42 million tonnes of forage dry matter were consumed from 2008 to 2009 by the UK ruminant livestock population of which 0.7 was grazed pasture and 0.3 million tonnes was conserved forage. In addition, almost 13 million tonnes of raw material concentrate feeds were used in the UK animal feed industry from 2008 to 2009 of which cereal grains comprised 5.3 and soyabean meal 1.9 million tonnes. The proportion of edible feed in typical UK concentrate formulations ranged from 0.36 for milk production to 0.75 for poultry meat production. Example systems of livestock production were used to calculate feed conversion ratios (FCR - feed input per unit of fresh product). FCR for concentrate feeds was lowest for milk at 0.27 and for the meat systems ranged from 2.3 for poultry meat to 8.8 for cereal beef. Differences in FCR between systems of meat production were smaller when efficiency was calculated on an edible input/output basis, where spring-calving/grass finishing upland suckler beef and lowland lamb production were more efficient than pig and poultry meat production. With the exception of milk and upland suckler beef, FCR for edible feed protein into edible animal protein were >1.0. Edible protein/animal protein FCR of 1.0 may be possible by replacing cereal grain and soyabean meal with cereal by-products in concentrate formulations. It is concluded that by accounting for the proportions of human-edible and inedible feeds used in typical livestock production systems, a more realistic estimate of efficiency can be made for comparisons between systems.  相似文献   

16.
Demographic composition and dynamics of animal and human populations are important determinants for the transmission dynamics of infectious disease and for the effect of infectious disease or environmental disasters on productivity. In many circumstances, demographic data are not available or of poor quality. Since 1999 Switzerland has been recording cattle movements, births, deaths and slaughter in an animal movement database (AMD). The data present in the AMD offers the opportunity for analysing and understanding the dynamic of the Swiss cattle population. A dynamic population model can serve as a building block for future disease transmission models and help policy makers in developing strategies regarding animal health, animal welfare, livestock management and productivity. The Swiss cattle population was therefore modelled using a system of ordinary differential equations. The model was stratified by production type (dairy or beef), age and gender (male and female calves: 0–1 year, heifers and young bulls: 1–2 years, cows and bulls: older than 2 years). The simulation of the Swiss cattle population reflects the observed pattern accurately. Parameters were optimized on the basis of the goodness-of-fit (using the Powell algorithm). The fitted rates were compared with calculated rates from the AMD and differed only marginally. This gives confidence in the fitted rates of parameters that are not directly deductible from the AMD (e.g. the proportion of calves that are moved from the dairy system to fattening plants).  相似文献   

17.
Nutrient management plans are used to reduce non-point source pollution from animal operations. These plans require manure analysis and use indices to determine nutrient availability. This study evaluated a modified method for determining nitrogen fractions in swine slurry stored under slatted floors, calculating plant available nitrogen, and characterizing nitrogen fractions by holding pit depth. Manure samples were collected from gestating sow and finishing pig holding pits at discrete depths. Ammonium, amino acid, and amino sugar concentrations were significantly different for gestation holding pits by depth, but finishing pig holding pit values were not significantly different by depth. Plant available nitrogen was approximately 74% for gestation and 67% for finishing barn manures. Nitrogen fraction analysis suggests land application of swine manure for crop growth should be managed based on type of nitrogen present in the manure, which can be highly correlated to animal growth stage.  相似文献   

18.
The potential impact of climate change by the year 2050 on intensive livestock systems in Britain is assessed through the use of simulation models of farming systems. The submodels comprise livestock feeding, livestock thermal balance and the thermal balance of controlled environment buildings and a stochastic weather generator. These are integrated to form system models for growing pigs and broiler chickens. They are applied to scenarios typical of SE England, which is the warmest region of the country and represents the worst case. For both species the frequency of severe heat stress is substantially increased, with a consequent risk of mortality. To offset this, it would be necessary to reduce stocking densities considerably, or to invest in improved ventilation or cooling equipment. Other effects on production are likely to be small.  相似文献   

19.
Indoor climate and air quality   总被引:2,自引:0,他引:2  
 In industrialized countries about 90% of the time is spent indoors. The ambient parameters affecting indoor thermal comfort are air temperature and humidity, air velocity, and radiant heat exchange within an enclosure. In assessing the thermal environment, one needs to consider all ambient parameters, the insulating properties of the occupants’ clothing, and the activity level of the occupants by means of heat balance models of the human body. Apart from thermal parameters, air quality (measured and perceived) is also of importance for well-being and health in indoor environments. Pollutant levels are influenced by both outdoor concentrations and by indoor emissions. Indoor levels can thus be lower (e.g. in the case of ozone and SO2) or higher (e.g. for CO2 and formaldehyde) than outdoor levels. Emissions from cooking play an important role, especially in developing countries. The humidity of the ambient air has a wide range of effects on the energy and water balance of the body as well as on elasticity, air quality perception, build-up of electrostatic charge and the formation or mould. However, its effect on the indoor climate is often overestimated. While air-handling systems are commonly used for achieving comfortable indoor climates, their use has also been linked to a variety of problems, some of which have received attention within the context of ”sick building syndrome”. Received: 27 October 1997 / Accepted 26 November 1997  相似文献   

20.

Background

Architectural design has the potential to influence the microbiology of the built environment, with implications for human health and well-being, but the impact of design on the microbial biogeography of buildings remains poorly understood. In this study we combined microbiological data with information on the function, form, and organization of spaces from a classroom and office building to understand how design choices influence the biogeography of the built environment microbiome.

Results

Sequencing of the bacterial 16S gene from dust samples revealed that indoor bacterial communities were extremely diverse, containing more than 32,750 OTUs (operational taxonomic units, 97% sequence similarity cutoff), but most communities were dominated by Proteobacteria, Firmicutes, and Deinococci. Architectural design characteristics related to space type, building arrangement, human use and movement, and ventilation source had a large influence on the structure of bacterial communities. Restrooms contained bacterial communities that were highly distinct from all other rooms, and spaces with high human occupant diversity and a high degree of connectedness to other spaces via ventilation or human movement contained a distinct set of bacterial taxa when compared to spaces with low occupant diversity and low connectedness. Within offices, the source of ventilation air had the greatest effect on bacterial community structure.

Conclusions

Our study indicates that humans have a guiding impact on the microbial biodiversity in buildings, both indirectly through the effects of architectural design on microbial community structure, and more directly through the effects of human occupancy and use patterns on the microbes found in different spaces and space types. The impact of design decisions in structuring the indoor microbiome offers the possibility to use ecological knowledge to shape our buildings in a way that will select for an indoor microbiome that promotes our health and well-being.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号