首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The pharmacokinetic studies of fenofibrate require a rapid, selective and robust method to allow the determination of fenofibric acid, its active metabolite, in different biological matrixes (such as plasma, serum or urine). A new fully automated method for the determination of fenofibric acid in plasma has been developed, which involves the solid-phase extraction (SPE) of the analyte from plasma on disposable extraction cartridges (DECs) and reversed-phase HPLC with UV detection. The SPE operations were performed automatically by means of a sample processor equipped with a robotic arm (ASPEC system). The DEC filled with octadecyl silica was first conditioned with methanol and pH 7.4 phosphate buffer. A 0.8-ml volume of diluted plasma sample containing the internal standard (sulindac) was then applied on the DEC. The washing step was performed with the same buffer (pH 7.4). Finally, the analytes were successively eluted with methanol (1.0 ml) and 0.04 M phosphoric acid (1.0 ml). After a mixing step, 100 μl of the resultant extract was directly introduced into the HPLC system. The liquid chromatographic (LC) separation of the analytes was achieved on a Nucleosil RP-8 stationary phase (5 μm). The mobile phase consisted of a mixture of methanol and 0.04 M phosphoric acid (60:40, v/v). The analyte was monitored photometrically at 288 nm. The method developed was validated. In these conditions, the absolute recovery of fenofibric acid was close to 100% and a linear calibration curve was obtained in the concentration range from 0.25 to 20 μg/ml. The mean RSD values for repeatability and intermediate precision were 1.7 and 3.9% for fenofibric acid. The method developed was successfully used to investigate the bioequivalence between a micronized fenofibrate capsule formulation and a fenofibrate Lidose™ formulation.  相似文献   

2.
3.
This study describes a HPLC method to determine the concentrations of acetylsalicylic acid (ASA) and salicylic acid (SA) in human stratum corneum and in plasma. The stratum corneum layers for ASA/SA analysis were removed from three patients with postherpetic hyperalgesia treated with topical and oral aspirin. Blood samples were also collected from the same patients. Tape strippings were placed in acetonitrile and sonicated for 15 min. After centrifuging, aliquots of the supernatant were injected into the chromatograph. ASA and SA from plasma samples were extracted on Isolute C8 columns. Due to interfering peaks in the tape samples, HPLC conditions were slightly different for tape and plasma samples. ASA and SA were separated on a LiChrospher 100 RP-18 column at 1 ml/min using a water–phosphate buffer (pH 2.5)–acetonitrile mobile phase (35:40:25, v/v/v). A linear response to quantities of ASA from 0.1 to 100 μg/cm2 and of SA from 0.1 to 5 μg/cm2 in tape and to quantities of ASA 0.1 to 2 μg/ml and 1 to 50 μg/ml was obtained and the recovery from tape and plasma samples was over 98%. The method is sensitive (0.1 μg/cm2) and specific enough to allow the determination of the drugs in the skin not only after topical but also after oral administration. A good sensitivity was also obtained in plasma (0.1 μg/ml) allowing study of the kinetics of ASA and SA in plasma after oral administration. Concentrations of ASA after topical administration were 100–200 times higher than after oral administration. Plasma levels of ASA and SA after oral administration were similar to those previously found. No ASA or SA were detected in plasma after topical ASA administration.  相似文献   

4.
Simultaneous determination of mycophenolic acid (MPA) and mycophenolate phenol glucuronide (MPAG) in plasma and urine was accomplished by isocratic HPLC with UV detection. Plasma was simply deproteinated with acetonitrile and concentrated, whereas urine was diluted prior to analysis. Linearity was observed from 0.2 to 50 μg/ml for both MPA and MPAG in plasma and from 1 to 50 μg/ml of MPA and 5 to 2000 μg/ml MPAG in urine with extraction recovery from plasma greater than 70%. Detection limits using 0.25 ml plasma were 0.080 and 0.20 μg/ml for MPA and MPAG, respectively. The method is more rapid and simple than previous assays for MPA and MPAG in biological fluids from patients.  相似文献   

5.
A method is described for the determination of pilocarpine and its degradation products isopilocarpine, pilocarpic acid and isopilocarpic acid in human plasma and urine. The method is based on a simple sample preparation step – ultrafiltration for plasma and dilution for urine samples – followed by a reversed-phase liquid chromatographic separation of the analytes and detection by means of tandem mass spectrometry. Parameters affecting the performance of these steps are discussed. The high sensitivity and selectivity of the method allow low ng/ml concentrations to be determined for all compounds in plasma and undiluted urine, which enables the investigation of the metabolic fate and elimination of pilocarpine after oral administration to humans.  相似文献   

6.
7.
A high-performance liquid chromatographic method for the determination of eltanolone in plasma has been developed. Plasma samples containing eltanolone were diluted with acetonitrile to precipitate plasma proteins, and derivatized with 2,4-dinitrophenylhydrazine before direct injection onto a C18 column. The mobile phase was acetonitrile–water (70:30, v/v) containing 0.1% trifluoroacetic acid and detection was by UV absorbance at 367 nm. The quantitation limit was 0.020 μg/ml. The method has proven to be rapid, precise and sensitive in the range of concentrations found during and following intravenous anaesthesia.  相似文献   

8.
A new method for the determination of omeprazole in human plasma was developed. Omeprazole was extracted from plasma with toluene-isoamylalcohol (95:5, v/v), the organic phase was evaporated, dissolved in the mobile phase and injected into a reversed-phase C18 column. Flunitrazepam was used as an internal standard. The mobile phase consisted of 47% methanol and 53% of 0.1 M dipotassium hydrogenphosphate, pH 7.8. The spectrophotometric detection was performed at 302 nm. Limit of quantitation was 9.7 ng/ml and the calibration curve was linear up to 1240 ng/ml.  相似文献   

9.
An assay using reversed-phase high-performance liquid chromatography with electrochemical detection was developed to measure hydroxyurea in plasma at concentrations suitable for pharmacokinetic studies. The sample preparation is simple, the analysis rapid and assays can be batched. The between-run precision is excellent (coefficient of VARIATION = 2.8–4.5%) and the limit of detection is 0.02 mmol/l. Preliminary studies have shown that the method is suitable for pharmacokinetic studies.  相似文献   

10.
11.
12.
A simple, selective and sensitive high-performance liquid chromatographic method with spectrophotometric detection was developed for the determination of antihyperglycemic agent metformin in human plasma using a novel sample extraction procedure. Liquid-liquid extraction of metformin and ranitidine (as internal standard) from plasma samples was performed with 1-butanol/n-hexane (50:50, v/v) in alkaline condition followed by back-extraction into diluted acetic acid. Chromatography was carried out using a silica column (250 mmx4.6 mm, 5 microm) under isocratic elution with acetonitrile-40 mM aqueous sodium dihydrogen phosphate (25:75, v/v), pH 6. The limit of quantification (LOQ) was 15.6 ng/ml and the calibration curves were linear up to 2000 ng/ml. The mean absolute recoveries for metformin and internal standard using the present extraction procedure were 98 and 95%, respectively. The intra- and inter-day coefficient of variation and percent error values of the assay method were all less than 8.3%.  相似文献   

13.
We developed and characterized a high-performance liquid chromatography (HPLC) assay for the determination of saquinavir, an HIV protease inhibitor, in human plasma samples. Extraction of plasma samples with diethyl ether resulted in quantitative recovery of both saquinavir and its stereoisomer Ro 31-8533 which was used as an internal standard. The assay was performed isocratically using 5 mM H2SO4 (pH 3.5) and acetonitrile (75.5:24.5, v/v) containing 10 mM tetrabutylammonium hydrogen sulfate (TBA) as a mobile phase, a Nucleosil 3C8 column kept at 45°C and UV detection at 240 nm. Using this method, saquinavir and Ro 31-8533 can be separated from endogenous substances, and in the concentration range of 5–110 ng/ml the relative standard deviations for the determination of saquinavir were below 5%. The detection limit of saquinavir in human plasma was 1 ng/ml. The usefulness of the method was demonstrated by quantification of saquinavir in plasma of human subjects treated with 600 mg of saquinavir per os or 12 mg intravenously.  相似文献   

14.
15.
The aim of the present study is to establish a highly sensitive method for the determination of uric acid (UA) in human saliva. The monitoring of UA levels in less invasive biological samples such as saliva is suggested for the diagnosis and therapy of gout, hyperuricemia, and the Lesch-Nyhan syndrome, and for detecting such conditions as alcohol dependence, obesity, diabetes, high cholesterol, high blood pressure, kidney disease, and heart disease. Reversed-phase high-performance liquid chromatography with electrochemical detection (HPLC-ED) was employed for the determination of UA obtained by solid-phase extraction from saliva. To quantify UA, we compared the ED efficiencies of an amperometric ED (Ampero-ED) with a single electrode and a coulometric ED (Coulo-ED) with a multiple electrode array. The results showed that the detection limits (S/N=3) were 3 nM for Ampero-ED and 6 nM for Coulo-ED, and the linearity of the calibration curves of 60-6000 nM had correlation coefficients exceeding 0.999. In addition, the total analytical time was 10 min. In the sample preparation of UA in saliva, an Oasis MAX solid-phase cartridge was used. The recoveries of UA spiked at 0.6 and 3 microM in saliva were above 95% with a relative standard deviation (RSD) of less than 15%. Therefore, the present method may be used in the routine and diagnostic determination of UA in human saliva.  相似文献   

16.
NG,NG-Dimethylarginine (asymmetric dimethylarginine, ADMA) can be directly separated and measured from deproteinized human plasma using o-phthaldialdehyde-mercaptoethanol (OPA reagent) as a fluorogenic reagent by reversed-phase high-performance liquid chromatography. The mean recovery of ADMA was over 96% and the inter- and intra-assay coefficients of variation of amounts were lower than 3.80% and those of retention time were below 0.37% for five runs. The detection limit of the assay is 1 pmol when the signal-to-noise is 3:1. It was observed that the concentration of ADMA was significantly elevated in plasma of patients with pregnancy induced hypertension (PIH) in contrast to healthy pregnant women.  相似文献   

17.
A selective and sensitive method for the determination of lipoic acid in human plasma samples has been developed. After enzymatic hydrolysis of the sample, the liberated lipoic acid was extracted by a solid-phase cartridge and measured by HPLC using electrochemical detection. The detection limit was 1 ng/ml lipoic acid in plasma. The calibration curve was non-linear in the range 0.01–50 μg/ml but could be described by a power function. The average extraction recoveries were 82.5 and 85.1% at the 25 and 2500 ng/ml levels, respectively. Coefficients of variation for both within-day and day-to-day analysis were between 2.1 and 9.4%. The assay method is sensitive, reproducible and suitable for disposition studies of lipoic acid in humans.  相似文献   

18.
A simple and sensitive high-performance liquid chromatographic method involving UV detection was developed for determination of caffeic acid in rabbit plasma. A Lichrosphere CN column (250 mm × 4 mm I.D., 5 μm) was used as the stationary phase and the mobile phase consisted of 2% acetic acid solution at a flow-rate of 1.0 ml/min. The UV absorbance was monitored at 320 nm. The plasma sample was acidified by the addition of 0.01 parts of concentrated phosphoric acid (85%) to maintain caffeic acid stability. After a simple clean-up procedure, the limit of quantitation achieved was 0.1 μg/ml, and the standard curve was found to be linear over the concentration ranges of 0.1–2.0 μg/ml and 0.1–40 μg/ml. The coefficient of variation for within- and between-run precision and accuracy was less than 10%, and the recovery was 82.3%.  相似文献   

19.
A high-performance liquid chromatographic assay for O6-benzylguanine utilizing liquid-liquid extraction and reversed-phase chromatography has been developed. Plasma samples were alkalinized, extracted into ethyl acetate, evaporated, and the residues were constituted and chromatographed. Separation was accomplished by gradient elution with a mobile phase of methanol, acetonitrile, and phosphate buffer, pH 3.2. Eluted compounds were detected spectrophotometrically at 280 nm. Sample quantitation was obtained from the regression line of six-point standard curves ranging from 25 to 400 ng/ml. O6-Benzylguanine peak heights were compared to peak heights of O6-(p-chlorobenzyl)guanine (internal standard). The average regression coefficient was 0.999 (n = 4). High concentration (305 ng/ml) and low concentration (38 ng/ml) quality control samples were determined with a day-to-day relative standard deviation of 7 and 8%, respectively (n = 18). The within-day relative standard deviations were 2.7 and 3.0% (n = 18) for the high and low concentration quality control specimens, respectively. Sample quantitation was reliable to 25 ng/ml with a signal-to-noise ratio of 8:1. This method was applied to plasma samples obtained from patients in a clinical trial of O6-benzylguanine.  相似文献   

20.
Using high-performance liquid chromatography (HPLC) with multigradient elution, (asymmetric-DMA, ADMA) and (symmetric-DMA, SDMA) can be separated from human plasma samples. The dimethylarginine compounds in plasma, after extraction with a cation-exchange column, are converted to fluorescent derivatives with o-phthaldialdehyde (OPA) in an alkaline medium and the derivatives are separated simultaneously within 50 min on a reversed-phase column (Ultracarb 3 ODS(20)). The recoveries of ADMA and SDMA are over 80% and the method permits quantitative determination of dimethylated arginines at concentrations as low as 0.1 μmol/l in human plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号