首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A sensitive and very specific method, using liquid chromatography–electrospray mass spectrometry (LC–ES-MS), was developed for the determination of epirubicin, doxorubicin, daunorubicin, idarubicin and the respective active metabolites of the last three, namely doxorubicinol, daunorubicinol and idarubicinol in human serum, using aclarubicin as internal standard. Once thawed, 0.5-ml serum samples underwent an automated solid-phase extraction, using C18 Bond Elut cartridges (Varian) and a Zymark Rapid-Trace robot. After elution of the compounds with chloroform–2-propanol (4:1, v/v) and evaporation, the residue was reconstituted with a mixture of 5 mM ammonium formate buffer (pH 4.5)–acetonitrile (60:40, v/v). The chromatographic separation was performed using a Symmetry C18, 3.5 μm (150×1 mm I.D.) reversed-phase column, and a mixture of 5 mM ammonium formate buffer (pH 3)–acetonitrile (70:30, v/v) as mobile phase, delivered at 50 μl/min. The compounds were detected in the selected ion monitoring mode using, as quantitation ions, m/z 291 for idarubicin and idarubicinol, m/z 321 for daunorubicin and daunorubicinol, m/z 361 for epirubicin and doxorubicin, m/z 363 for doxorubicinol and m/z 812 for aclarubicin (I.S.). Extraction recovery was between 71 and 105% depending on compounds and concentration. The limit of detection was 0.5 ng/ml for daunorubicin and idarubicinol, 1 ng/ml for doxorubicin, epirubicin and idarubicin, 2 ng/ml for daunorubicinol and 2.5 ng/ml for doxorubicinol. The limit of quantitation (LOQ) was 2.5 ng/ml for doxorubicin, epirubicin and daunorubicinol, and 5 ng/ml for daunorubicin, idarubicin, doxorubicinol and idarubicinol. Linearity was verified from these LOQs up to 2000 ng/ml for the parent drugs (r≥0.992) and 200 ng/ml for the active metabolites (r≥0.985). Above LOQ, the within-day and between-day precision relative standard deviation values were all less than 15%. This assay was applied successfully to the analysis of human serum samples collected in patients administered doxorubicin or daunorubicin intravenously. This method is rapid, reliable, allows an easy sample preparation owing to the automated extraction and a high selectivity owing to MS detection.  相似文献   

2.
A method was developed for the determination in human urine of S-phenylmercapturic (PMA) and S-benzylmercapturic (BMA) acids, metabolites respectively of benzene and toluene. PMA and BMA were determined, after alkaline hydrolysis, to give respectively thiophenol and benzylmercaptan, and coupling of the thiol-containing compounds with monobromobimane (MB), by reversed-phase HPLC on a diphenyl-silica bonded cartridge (100×4.6 mm I.D., 5 μm particle size) with fluorimetric detection. Wavelengths for excitation and emission were 375 and 480 nm, respectively. The recovery of PMA and BMA from spiked urines was >90% in the 10–500 μg/l range; the quantification limits were respectively 1 and 0.5 μg/l; day-to-day precision at 42 μg/l was C.V. <7%. The suitability of the proposed procedure for the biological monitoring of exposure to low-level airborne concentrations of benzene and toluene, was evaluated by analyzing the urinary excretion of PMA and BMA in subjects exposed to different sources of aromatic hydrocarbons, namely occupationally-unexposed referents (non-smokers, n=15; moderate smokers, n=8; mean number of cigarettes smoked PER-DAY=17 cig/day) and non-smoker workers occupationally exposed to toluene in maintenance operations of rotogravure machines (non-smokers, n=17). Among referents, non-smokers showed values of PMA ranging from <1 to 4.6 μg/l and BMA from 1.0 to 10.4 μg/l; in smokers, PMA values ranging from 1.2 to 6.7 μg/l and BMA from 9.3 to 39.9 μg/l, were observed. In occupationally exposed non-smoker subjects, BMA median excretion value (23.6 μg/l) was higher than in non-smoker referents (3.5 μg/l) (P<0.001) and individual BMA values (y, μg/l) were associated and increased with airborne toluene concentration (x, mg/m3) according to the equation y=6.5+0.65x (r=0.69, P<0.01, n=17). The proposed analytical method appears to be a sensitive and specific tool for biological monitoring of low-level exposure to benzene and toluene mixtures in occupational and environmental toxicology laboratory.  相似文献   

3.
A reliable reversed-phase high-performance liquid chromatographic method has been developed for the determination of bromocriptine (BCT) in plasma and eye tissues. The BCT and propranolol, added as an internal standard (I.S.), were extracted by a liquid–liquid technique followed by an aqueous back-extraction, allowing injection of an aqueous solvent into a 4-μm Nova-Pak C18 column (150×3.9 mm I.D.). The mobile phase was a mixture of 30 parts of acetonitrile and 70 parts of 0.2% triethylamine (pH 3) at a flow-rate of 1 ml/min. Fluorescence detection was at an excitation wavelength of 330 nm and an emission wavelength of 405 nm. The retention times of I.S. and BCT were 4.1 and 11.6 min, respectively. The calibration curve was linear over the concentration range 0.2–10 μg/l for plasma (r>0.999) and vitreous humour (r>0.997) and 1–50 μg/l for aqueous humour (r>0.985). The limit of quantification was 0.2 μg/l for plasma and vitreous humour using a 1-ml sample and was 1 μg/l for aqueous humour using a 0.2-ml sample. The quality control samples were reproducible with acceptable accuracy and precision. The within-day recovery (n=3) was 100–102% for plasma, 91–106% for aqueous humour and 96–111% for vitreous humour. The between-day recovery (n=9) was 90–114% for plasma, 83–115% for aqueous humour and 90–105% for vitreous humour. The within-day precision (n=3) and the between-day precision (n=9) were 1.7–7.0% and 8.1–13.6%, respectively. No interferences from endogenous substances were observed. Taken together, the above simple, sensitive and reproducible high-performance liquid chromatography assay method was suitable for the determination of BCT in plasma and eye tissues following ocular application of BCT for the therapy of myopia.  相似文献   

4.
A reliable reversed-phase high-performance liquid chromatographic method has been developed for the determination of a new oral thrombin inhibitor (compound I) in the blood of rats and dogs. The analyte was deproteinized with a 1.5 volume of methanol and a 0.5 volume of 10% zinc sulfate, and the supernatant was injected into a 5-μm Capcell Pak C18 column (150×4.6 mm I.D.). The mobile phase was a mixture of acetonitrile and 0.2% triethylamine of pH 2.3 (31:69, v/v) with a flow-rate of 1.0 ml/min at UV 231 nm. The retention time of compound I was approximately 9.3 min. The calibration curve was linear over the concentration range of 0.05–100 mg/l for rat blood (r2>0.9995, n=6) and dog blood (r2>0.9993, n=6). The limit of quantitation was 0.05 mg/l for both bloods using a 100-μl sample. For the 5 concentrations (0.05, 0.1, 1, 10, and 100 mg/l), the within-day recovery (n=4) and precision (n=4) were 98.1–104.1% and 1.5–6.8% for rat blood and 95.4–105.7% and 1.4–5.3% for dog blood, respectively. The between-day recovery (n=6) and precision (n=6) were 99.8–105.3% and 3.7–12.6% for rat blood and 87.5–107.1% and 2.9–15.3% for dog blood, respectively. The absolute recoveries were 82.4–93.3%. No interferences from endogenous substances were observed. In conclusion, the presented simple, sensitive, and reproducible HPLC method proved and was used successfully for the determination of compound I in the preclinical pharmacokinetics.  相似文献   

5.
A GC method using a novel derivatization reagent, 2′,2′,2-trifluoroethyl chloroformate (TFECF), for the derivatization of primary and secondary aliphatic amines with the formation of carbamate esters is presented. The method is based on a derivatization procedure in a two-phase system, where the carbamate ester is formed. The method is applied to the determination of 1,6-hexamethylene diamine (HDA) in aqueous solutions and human urine, using capillary GC. Detection was performed using thermionic specific detection (TSD) and mass spectrometry (MS)—selective-ion monitoring (SIM) using electron-impact (EI) and chemical ionization (CI) with ammonia monitoring both positive (CI)+ and negative ions (CI). Quantitative measurements were made in the chemical ionization mode monitoring both positive and negative ions. Tetra-deuterium-labelled HDA (TDHDA; H2NC2H2(CH2)4C2H2NH2) was used as the internal standard for the GC—MS analysis. In CI+ the m/z 386 and the m/z 390 ions corresponding to the [M + 18]+ ions (M = molecular ion) of HDA—TFECF and TDHDA—TFECF were measured; in CI the m/z 267 and the m/z 271 ions corresponding to the [M — 101] ions. The overall recovery was found to be 97 ± 5% for a HDA concentration of 1000 μg/l in urine. The minimal detectable concentration in urine was found to be less than 20 μg/l using GC—TSD and 0.5 μg/l using GC—SIM. The overall precision for the work-up procedure and GC analysis was ca. 3% (n = 5) for 1000 μg/l HDA-spiked urine, and ca. 4% (n = 5) for 100 μg/l. The precision using GC—SIM for urine samples spiked to a concentration of 5 μg/l was found to be 6.3% (n = 10).  相似文献   

6.
A reliable reversed-phase high-performance liquid chromatographic method has been developed for the determination of LB71350 in the plasma of dogs. The analyte was deproteinized with 1.5 volumes of methanol and 0.5 volumes of 10% zinc sulfate, and the supernatant was injected into a 5-μm Capcell Pak C18 column (150×4.6 mm I.D.). The mobile phase was a stepwise gradient mixture of acetonitrile and 0.2% triethylamine–HCl with a flow-rate of 1 ml/min and detection at UV 245 nm. The proportion of acetonitrile was kept at 52% for the first 6 min, increased to 100% for the next 0.5 min, kept at 100% for the next 2 min, decreased to 52% for the next 0.5 min, and finally kept at 52% for the next 7 min. The retention time of LB71350 was 6.9 min. The calibration was linear over the concentration range of 0.1–100 mg/l for dog plasma (r>0.997) and the limit of quantitation was 0.1 mg/l using 0.1 ml plasma. The quality control samples were reproducible with acceptable accuracy and precision at 0.1, 1, 10 and 100 mg/l concentrations. The within-day recovery (n=5) was 90.2–93.9%, the between-day recovery (n=5) was 89.5–93.5%, and the absolute between-day recovery (n=5) was 77–81%. The within-day precision (n=5) and between-day precision (n=5) were 2.59–5.82% and 3.17–4.55%, respectively. No interferences from endogenous substances were observed. Taken together, the above HPLC assay method by deproteinization and UV detection was suitable for the determination of LB71350 in the preclinical pharmacokinetics.  相似文献   

7.
An improved high-performance liquid chromatographic assay for the cytostatic drug mitomycin C in plasma is presented. The principal steps are precipitation of plasma proteins with acetonitrile, lyophilization of the supernatant and reversed-phase chromatography on a Hypersil ODS 5 μm column with 0.01 M NaH2PO4 buffer (pH 6.5)-methanol (70:30, v/v) in isocratic mode. At a flow-rate of 1.3 ml/min a column pressure of 180–220 bar resulted. Porfiromycin served as internal standard. UV detection was performed at 365 nm. Quantitation limit based on a coefficient of variation <10% in intra- and inter-day assay was 5 μg/l mitomycin C, detection limit based on a signal-to-noise ratio of 3 was 1 μg/l. Recovery was 100% and linearity was shown for the whole range of concentration (1–500 μg/l). None of the five drugs used during chemoembolisation interfered with the assay in vitro. The assay meets the requirements for pharmacokinetic studies of mitomycin C in patients as regards sensitivity and ease of use.  相似文献   

8.
A high-performance liquid chromatographic method has been developed for the simultaneous determination of mycophenolic acid (MPA) and its glucuronide conjugate (MPAG) in human plasma. The method involves protein precipitation with acetonitrile, followed by ion-pair reversed-phase chromatography on C18 column, with a 40 mM tetrabutyl ammonium bromide (TBA)–acetonitrile (65:35, v/v) mobile phase. A 20-μl volume of clear supernatant was injected after centrifugation, and the eluent was monitored at 304 nm. No interference was found either with endogenous substances or with many concurrently used drugs, indicating a good selectivity for the procedure. Calibration curves were linear over a concentration range of 0.5–20.0 μg/ml for MPA and 5–200 μg/ml for MPAG. The accuracy of the method is good, that is, the relative error is below 5%. The intra- and inter-day reproducibility of the analytical method is adequate with relative statistical deviations of 6% or below. The limits of quantification for MPA and MPAG were lower than 0.5 and 5.0 μg/ml, respectively, using 50 μl of plasma. The method was used to determine the pharmacokinetic parameters of MPA and MPAG following oral administration in a patient with renal transplantation.  相似文献   

9.
We extended the application of a sensitive high-performance liquid chromatography assay of amoxicillin developed in this laboratory for human plasma and middle ear fluid (MEF) to other sample matrices including chinchilla plasma or MEF and human and chinchilla whole blood with minor modification and validated the limit of quantitation at 0.25 μg/ml with a 50-μl sample size for human and chinchilla plasmas or MEFs. Amoxicillin and cefadroxil, the internal standard, were extracted from 50 μl of the samples with Bond Elut C18 cartridges. The extract was analyzed on a Keystone MOS Hypersil-1 (C8) column with UV detection at 210 nm. The mobile phase was 6% acetonitrile in 5 mM phosphate buffer, pH 6.5 and 5 mM tetrabutylammonium. The within-day coefficients of variation were 2.7–9.9 (n=4) and 1.7–7.2% (n=3) for chinchilla plasma and MEF samples, respectively; 2.8–8.1% (n=3) and 2.9–4.7% (n=3) for human and chinchilla whole blood, respectively. An alternative mobile phase composition for chinchilla plasma and MEF samples reduced the analysis time significantly.  相似文献   

10.
A new high-performance liquid chromatograhic procedure for simultaneous determination of pyrazinamide (PZA) and its three metabolites 5-hydroxypyrazinamide (5-OH-PZA), pyrazinoic acid (PA), and 5-hydroxypyrazinoic acid (5-OH-PA), in rat urine was developed. 5-OH-PZA and 5-OH-PA standards were obtained by enzymatic synthesis (xanthine oxidase) and checked by HPLC and GC–MS. Chromatographic separation was achieved in 0.01 M KH2PO4 (pH 5.2), circulating at 0.9 ml/min, on a C18 silica column, at 22°C. The limits of detection were 300 μg/l for PZA, 125 μg/l for PA, 90 μg/l for 5-OH-PZA and 70 μg/l for 5-OH-PA. Good linearity (r2>0.99) was observed within the calibration ranges studied: 0.375–7.50 mg/l for PZA, 0.416–3.33 mg/l for PA, 0.830–6.64 mg/l for 5-OH-PZA and 2.83–22.6 mg/l for 5-OHPA. Accuracy was always lower than ±10.8%. Precision was in the range 0.33–5.7%. The method will constitute a useful tool for studies on the influence of drug interactions in tuberculosis treatment.  相似文献   

11.
An ion-pair reversed-phase high-performance liquid chromatographic method with fluorimetric detection, using lumogallion [4-chloro-3-(2,4-dihydroxyphenylazo)-2-hydroxybenzene-1-sulphonic acid] as a ligand, has been successfully applied to the determination of aluminium in human serum. The highly fluorescent aluminium-lumogallion complex (λex 505 nm, λem 574 nm) was separated on a LiChrosorb RP-18 column with an eluent consisting of 30% acetonitrile, 70% 0.02 M potassium hydrogen phthalate and 10 μM lumogallion. The proposed system offers a simple, rapid, selective and sensitive method for the determination of aluminium in serum. The detection limit for aluminium was 0.05 μg/l in aqueous solution and the limit of determination was 2.2 μg/l in serum. The recovery of the method is generally over 90%.  相似文献   

12.
A reversed-phase high-performance liquid chromatographic method is described for the simultaneous determination of idarubicin and idarubicinol in rat plasma. Blood samples were analyzed from 16 rats which had received an intravascular dose of 2.25 mg kg−1 idarubicin. After deproteinization with acetonitrile, the separation was performed with a LiChrospher 100 RP-18 column (5 μm), using fluorescence detection (excitation: 485 nm/emission: 542 nm). The mean recovery was 95.6% for idarubicin and 90.7% for idarubicinol, respectively. The detection limit was 0.25 ng ml−1 using an injection volume of 50 μl. Daily relative standard deviation (RSD) was 3.2% (10 ng idarubicin/ml, n=10) and 4.4% (10 ng idarubicinol/ml, n=10).  相似文献   

13.
This report describes a rapid, simple and sensitive isocratic high-performance liquid chromatography with diode array UV detection for micro-sample analysis of paclitaxel in mouse plasma. The analysis utilized a Capcell-pak octadecyl analytical column and a mobile phase consisting of acetonitrile–0.1% phosphoric acid in deionized water (55:45, v/v). Paclitaxel and n-hexyl p-hydroxybenzoic acid (internal standard) were extracted from plasma by one-step extraction with tert.-butyl methyl ether. Peak purity was determined over a UV wavelength range of 200 to 400 nm. Paclitaxel and the internal standard were eluted at 3.4 min and 5.4 min, respectively, at a mobile phase flow-rate of 1.3 ml/min. No interfering peaks were observed and the total run time was 10 min. The standard curve was linear (r=0.9999) over the concentration range of 0.010–500 μg/ml. The extraction recovery was >90% for both paclitaxel and n-hexyl p-hydroxybenzoic acid. The intra- and inter-day assay variabilities of paclitaxel ranged from 0.4 to 2.2% and 0.6 to 7.8%, respectively. The LOD and LOQ were 5 and 10 ng/ml, respectively, for paclitaxel using a plasma sample volume of 100 μl. This highly sensitive and simple assay method was successfully applied to a pharmacokinetic study after i.v. administration of paclitaxel 20 mg/kg to mice.  相似文献   

14.
A selective HPLC method is described for the determination of cefpodoxime levels in plasma and sinus mucosa. Sample preparation included solid-phase extraction with a C8 cartridge. Cefpodoxime and cefaclor (internal standard) were eluted with methanol and analyzed on an optimised system consisting of a C18 stationary phase and a ternary mobile phase (0.05 M acetate buffer pH 3.8—methanol—acetonitrile, 87:10:3, v/v) monitored at 235 nm. Linearity and both between- and within-day reproducibility were assessed for plasma and sinus mucosa samples. Inter-assay coefficients of variation were lower than 13.6% (n = 10) for plasma (0.2 μg/ml) and lower than 12.4% (n = 5) for sinus mucosa (0.25 μg/g). The quantification limit was 0.05 μg/ml for plasma and 0.13 μg/g for tissue. The method was used to study the diffusion of cefpodoxime in sinus mucosa.  相似文献   

15.
The determination of 3-hydroxyquinine in urine and plasma samples is described. Extraction was performed using a mixture of toluene–butanol (75:25, v/v), followed by back-extraction into the mobile phase, which consisted of 0.1 M phosphate buffer, acetonitrile, tetrahydrofuran and triethylamine. A reversed-phase liquid chromatography system with fluorescence detection and a CT-sil C18 column were used. The within-assay coefficient of variation of the method was 2% at the higher concentration values in plasma, 2.95 μM, 4% at 227 nM and 9% at the lower limit of quantitation, 4.5 nM. In urine, the coefficient of variation was 11% at the lower concentration, 227 nM and was 3% at 56.8 μM. The between-assay coefficient of variation was 4% at the low concentration (5.1 nM) in plasma, 2% at 276.8 nM and 3% at 1.97 μM. In urine, the between assay coefficient of variation was 4% at 204.6 nM, 3% at 5.12 μM and 2% at 56.8 μM.  相似文献   

16.
Separation in capillary electrophoresis is governed by various factors, including buffer type, buffer concentration, pH, temperature, voltage and micelles. Through proper adjustment of these parameters, nalidixic acid and its two major metabolites, 7-hydroxynalidixic and 7-carboxynalidixic, could be separated by micellar electrokinetic capillary chromatography using an electrophoretic electrolyte consisting of 50 mM borate buffer (pH 9) containing 25 mM sodium dodecyl sulphate and 10% acetonitrile. A linear relationship between concentration and peak area for each compound was obtained in the concentration range 0.15–100 μg ml−1, with a correlation coefficient greater than 0.999 and detection limits in the 0.2–0.7 ng ml−1 range. Intra- and inter-day precision values of about 0.8–1.2% RSD (n=11) and 1.3–2.0% RSD (n=30), respectively, were obtained. The method has been applied to the analysis of nalidixic acid and its two major metabolites in serum and urine with limits of sensitivity lower than 0.8 ng ml−1.  相似文献   

17.
18.
A rapid and simple method for determination of the novel antiepileptic compound gabapentin [1-(aminomethyl)cyclohexaneacetic acid] in plasma is described. Blank human plasma was spiked with gabapentin (1.0–10.0 μg/ml) and internal standard [1-(aminomethyl)-cycloheptaneacetic acid; 5.0 μg/ml]. Individual samples were treated with 2 M perchloric acid, centrifuged and then derivatised with o-phthalaldehyde-3-mercaptopropionic acid. Separation was achieved on a Beckman Ultrasphere 5 μm reversed-phase column with mobile phase consisting of 0.33 M acetate buffer (pH 3.7; containing 100 mg/l EDTA)-methanol-acetonitrile (40:30:30, v/v). Eluents were monitored by fluorescence spectroscopy with excitation and emission wavelengths of 330 and 440 nm, respectively. The calibration curve for gabapentin in plasma was linear (r=0.9997) over the concentration range 1.0–10.0 μg/ml. Recovery was seen to be 90%. The inter- and intra-assay variations for three different gabapentin concentrations were 10% throughout. The lower limit of quantitation was found to be 0.5 μg/ml. Chromatography was unaffacted by a range of commonly employed antiepileptic drugs or selected amino acids.  相似文献   

19.
A 0.5-ml aliquot of a serum sample, after the addition of a 100-μl aliquot of a 5 μg/ml solution of dibucaine as the internal standard, is vortex-mixed with 0.5 ml of acetonitrile and centrifuged. The supernatant is applied to a 1-ml BondElut C18 silica extraction column conditioned with subsequent washings with 1 M HCl, methanol and water. After passing the sample at a slow rate, the column is washed twice with water and once with acetonitrile. The desired compounds are then eluted with a 0.25-ml aliquot of 35% perchloric acid—methanol (1:40, v/v). A 7-μl aliquot of the eluate is injected onto a 150 × 4.6 mm I.D. column packed with 5-μm C8 silica particles and eluted at ambient temperature with a mobile phase of 10 mM phosphate buffer-acetonitrile (2:1, v/v) (pH 3.2). The peaks are detected with a fluorescence detector (excitation at 295 nm, emission at 365 nm). The resulting chromatogram is clean with no extraneous peaks. Paroxetine and dibucaine give sharp peaks which are well separated from each other and from the solvent peaks. The extraction recovery of the drug and the internal standard is in the range of 90% which allows a highly sensitive determination of paroxetine.  相似文献   

20.
A specific and sensitive analytical method for the determination of sparfloxacin in serum and urine is described. Serum proteins are removed by precipitation with acetonitrile after the addition of ofloxacin as an internal standard. The supernatant solvent is evaporated in a vacuum concentrator and the dry residue is redissolved in the mobile phase. Separation is performed on a cation-exchange column (Nucleosil 100 5SA, 125 × 4.0 mm I.D., 5 μm particle size) protected by a guard column (Perisorb RP-18, 30 × 4.0 mm I.D., 30–40 μm particle diameter). The mobile phase consisted of 750 ml of acetonitrile and 250 ml of 100 mmol/l phosphoric acid (v/v) to which sodium hydroxide had been added. The final concentration of sodium was 23 mmol/l and the pH was 3.82. Sparfloxacin and ofloxacin were determined by spectrofluorimetry (excitation wavelength 295 nm; emission wavelength 525 nm). The flow-rate was 1.5 ml/min and the retention times were 4.7 (sparfloxacin) and 8.0 (ofloxacin) min. Validation of the method yielded the following results for serum: detection limit 0.05 mg/l; precision between series 10.4-3.6%; recovery 99.5–100.0%; comparison with a microbiological assay c(bioassay) = 1.035c(HPLC) − 0.06. The test organism was Bacillus subtilis ATCC 6633. For urine the results were: detection limit 0.5 mg/l; precision between series 7.8-5.0%; recovery 97.0–97.8%; method comparison c(bioassay) = 1.092c(HPLC) − 1.09. No interferences were observed in human volunteers. The method can also be applied to stool samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号