首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We describe a liquid chromatography-electrospray ionisation tandem mass spectrometry method for the qualitative and quantitative determination of the secoiridoid oleuropein and its bioactive metabolite hydroxytyrosol in rat plasma and urine. Samples were prepared by liquid-liquid extraction using ethyl acetate with a recovery for both compounds of about 100% in plasma and about 60% in urine. The chromatographic separation was performed with a RP-ODS column using a water-acetonitrile linear gradient. The calibration curve was linear for both biophenols over the range 2.5-1000 ng/ml (LOD 1.25 ng/ml) for plasma and 5-1000 ng/ml (LOD 2.5 ng/ml) for urine. Plasma concentrations of oleuropein and hydroxytyrosol were measured after oral administration of a single dose (100 mg/kg) of oleuropein. Analysis of treated rat plasma showed the presence of unmodified oleuropein, reaching a peak value of 200 ng/ml within 2 h, with a small amount of hydroxytyrosol, whereas in urine, both compounds were mainly found as glucuronides.  相似文献   

2.
The recombinant beta-glycosidase (EcS beta gly) from Sulfolobus solfataricus was immobilised on chitosan to perform the enzymatic hydrolysis of commercial oleuropein (heterosidic ester of elenolic acid and 3,4-dihydroxy-phenylethanol (hydroxytyrosol)) at two temperatures (60 and 70 degrees C). Interestingly, on the basis of the reasonable assumption that the enzyme hydrolyses only the sugar linkage, the biotransformation produces unstable aglycone species formed by oleuropein hydrolysis that, differently from some commercially available beta-glucosidases tested, give rise to the formation of hydroxytyrosol, at the operative temperatures of the bioreactor. The results of the biotransformation at 70 degrees C showed that the main products are hydroxytyrosol, and glucose, being the oleuropein aglycone present in low amount at the end of reaction. Both in single step approach or in recycle approach the amounts of glucose and oleuropein aglycone were lightly dependent from flow rate. The amount of hydroxytyrosol, increased on decreasing the flow rate of bioreactor in recycle approach, following a non-linear trend and obtaining the highest value at a flow rate of 15 ml h-1 while in the single step approach the 3,4-dihydroxy-phenylethanol was at its maximum at higher flow rate (16 ml h-1). For the hydrolysis of the oleuropein by bioreactor at 60 degrees C we used lower molar ratio oleuropein/enzyme only by the single step approach. In these conditions it is possible to obtain high amounts of only two products (glucose and hydroxytyrosol) in short time (2 h). The stability of the bioreactor at the operative temperatures showed a t1/2 of 30 days at 70 degrees C and a t1/2 of 56 days at 60 degrees C.  相似文献   

3.
A new simple and rapid high-performance liquid chromatographic (HPLC) method with UV detection for the determination of indapamide in biological fluids has been developed. Indapamide and internal standard were isolated from serum and whole blood samples by solid-phase extraction with RP select B cartridges. The chromatographic separation was accomplished on a reversed-phase C(8) column with a mobile phase composed of 0.1% (v/v) triethylamine in water (pH 3.5) and acetonitrile (63:37, v/v). UV detection was set at 240 nm. The calibration curves were linear in the concentration range of 10.0-100.0 ng/ml for serum, and 50.0-500.0 ng/ml for whole blood, and the limits of quantification were 10.0 and 50.0 ng/ml, respectively.  相似文献   

4.
A sensitive chromatographic assay has been developed for m-iodobenzylguanidine (MIBG) in human plasma based on the derivatization with benzoin. MIBG is first isolated from plasma using solid-phase extraction on a cyanopropyl-modified silica phase. After evaporation of the eluate, a fluorescent derivative is formed using benzoin. The derivative is analysed by reversed-phase liquid chromatography using a mixture 60% (v/v) acetonitrile, 30% (v/v) water and 10% (v/v) of the 0.5 M Tris buffer (pH 8.0) as the eluent and fluorescence detection at 320 nm for excitation and 435 nm for emission, respectively. In the evaluated concentration range (2–200 ng/ml) precisions 10% and accuracies in between 90 and 100% have been found, with 2 ng/ml being the lower limit of quantification using a 0.5-ml plasma sample volume. The assay can also be used without the internal standard benzylguanidine. The assay was successfully used to obtain a pharmacokinetic curve of MIBG.  相似文献   

5.
6.
A rapid method for the quantification of amiodarone and desethylamiodarone in animal plasma using high-performance liquid chromatography combined with UV detection (HPLC-UV) is presented. The sample preparation includes a simple deproteinisation step with acetonitrile. In addition, a sensitive method for the quantification of amiodarone and desethylamiodarone in horse plasma and urine using high-performance liquid chromatography combined with electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) is described. The sample preparation includes a solid-phase extraction (SPE) with a SCX column. Tamoxifen is used as an internal standard for both chromatographic methods. Chromatographic separation is achieved on an ODS Hypersil column using isocratic elution with 0.01% diethylamine and acetonitrile as mobile phase for the HPLC-UV method and with 0.1% formic acid and acetonitrile as mobile phase for the LC-MS/MS method. For the HPLC-UV method, good linearity was observed in the range 0-5 microg ml(-1), and in the range 0-1 microg ml(-1) for the LC-MS/MS method. The limit of quantification (LOQ) was set at 50 and 5 ng ml(-1) for the HPLC-UV method and the LC-MS/MS method, respectively. For the UV method, the limit of detection (LOD) was 15 and 10 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs of the LC-MS/MS method in plasma were much lower, i.e. 0.10 and 0.04 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The LODs obtained for the urine samples were 0.16 and 0.09 ng ml(-1) for amiodarone and desethylamiodarone, respectively. The methods were shown to be of use in horses. The rapid HPLC-UV method was used for therapeutic drug monitoring after amiodarone treatment, while the LC-MS/MS method showed its applicability for single dose pharmacokinetic studies.  相似文献   

7.
NC100668 is being developed as a new tracer for radiopharmaceutical imaging of venous thromboembolism. NC100668 consists of a targeting peptide of 13 amino acids with a (99m)Tc-binding chelator linked to the C-terminal amino acid. The present report describes a method for quantification of NC100668 in human citrated plasma. The method is based on solid-phase extraction followed by reversed-phase liquid chromatography using a gradient of water and acetonitrile with 0.1% formic acid. The chromatographic system was coupled on-line with an electrospray mass spectrometer. The analyses were performed by selective ion monitoring of the [M+2H]2+ and the [M+3H]3+ ions of NC100668 and an internal standard which was identical to NC100668 except for not being iodinated in the tyrosine residue. The limit of quantification of the method was 2ng NC100668/ml plasma. The calibration curve ranged from 2 to 250 ng NC100668/ml plasma and was fitted to a linear equation with a weighing factor of 1/y2 and found to be highly reproducible. The total precision of the method, expressed as the relative standard error of the mean, was 23.2, 8.8 and 14.7% for the low, medium and high control samples, respectively. The accuracy of the method was 108.5, 100.0 and 105.0% for the low, medium and high control samples, respectively. NC100668 was stable in human plasma during at least three freeze/thaw cycles, during 30 h on dry ice and up to 3 months when stored in a -20 degrees C freezer.  相似文献   

8.
A reliable high-performance liquid chromatographic method has been validated for determination of gallamine in rat plasma, muscle tissue and microdialysate samples. A C18 reversed-phase column with mobile phase of methanol and water containing 12.5 mM tetrabutyl ammonium (TBA) hydrogen sulphate (22:78, v/v) was used. The flow-rate was 1 ml/min with UV detection at 229 nm. Sample preparation involved protein precipitation with acetonitrile for plasma and muscle tissue homogenate samples. Microdialysate samples were injected into the HPLC system without any sample preparation. Intra-day and inter-day accuracy and precision of the assay were <13%. The limit of quantification was 1 μg/ml for plasma, 1.6 μg/g for muscle tissue and 0.5 μg/ml for microdialysate samples. The assay was applied successfully to analysis of samples obtained from a pharmacokinetic study in rats using the microdialysis technique.  相似文献   

9.
A rapid, sensitive and simple high-performance liquid chromatographic (HPLC) method with ultraviolet detector (UV) has been developed for the determination of bifendate in 100 microl plasma of rats. Sample preparation was carried out by deproteinization with 100 microl of acetonitrile. A 20 microl of supernatant was directly injected into the HPLC system with methanol-double distilled water (65/35, v/v) as the mobile phase at a flow rate of 1.0 ml/min. Separation was performed with a microBondapak C(18) column at 30 degrees C. The peak was detected at 278 nm. The calibration curve was linear (r(2)=0.9989) in the concentration range of 0.028-2.80 microg/ml in plasma. The intra- and inter-day variation coefficients were not more than 6.55% and 6.07%, respectively. The limit of detection was 5 ng/ml. The mean recoveries of bifendate were ranged from 94.53% to 99.36% in plasma. The present method has been successfully applied to the pharmacokinetic study of bifendate liposome in rats.  相似文献   

10.
Olive oil intake has been shown to induce significant levels of apoptosis in various cancer cells. These anti-cancer properties are thought to be mediated by phenolic compounds present in olive. These beneficial health effects of olive have been attributed, at least in part, to the presence of oleuropein and hydroxytyrosol. In this study, oleuropein and hydroxytyrosol, major phenolic compound of olive oil, was studied for its effects on growth in MCF-7 human breast cancer cells using assays for proliferation (MTT assay), cell viability (Guava ViaCount assay), cell apoptosis, cellcycle (flow cytometry). Oleuropein or hydroxytyrosol decreased cell viability, inhibited cell proliferation, and induced cell apoptosis in MCF-7 cells. Result of MTT assay showed that 200 μg/mL of oleuropein or 50 μg/mL of hydroxytyrosol remarkably reduced cell viability of MCF-7 cells. Oleuropein or hydroxytyrosol decrease of the number of MCF-7 cells by inhibiting the rate of cell proliferation and inducing cell apoptosis. Also hydroxytyrosol and oleuropein exhibited statistically significant block of G1 to S phase transition manifested by the increase of cell number in G0/G1 phase.  相似文献   

11.
A high-performance liquid chromatographic (HPLC) method with fluorescence detection has been developed for the determination of rizatriptan in human plasma. Following a single-step liquid-liquid extraction with methyl tertiarybutyl ether, the analytes were separated using a mobile phase consisting of 0.05% (v/v) triethylamine in water (adjusting to pH 2.75 with 85% phosphoric acid) and acetonitrile (92:8, v/v). Fluorescence detection was performed at an excitation wavelength of 225nm and an emission wavelength of 360nm. The linearity for rizatriptan was within the concentration range of 0.5-50ng/ml. The intra- and inter-day precisions of the method were not more than 8.0%. The lower limit of quantification (LLOQ) was 0.5ng/ml for rizatriptan. The method was sensitive, simple and repeatable enough to be used in pharmacokinetic studies.  相似文献   

12.
The aim of this work is to study the conversion of oleuropein-a polyphenol present in olives and olive oil by-products-into hydroxytyrosol, a polyphenol with antioxidant and antibacterial properties. The hydrolysis reaction is performed by lactic acid bacteria. Six bacterial strains (Lactobacillus plantarum 6907, Lactobacillus paracasei 9192, Lactobacillus casei, Bifidobacterium lactis BO, Enterococcus faecium 32, Lactobacillus LAFTI 10) were tested under aerobic and anaerobic conditions. The oleuropein degradation and hydroxytyrosol formation were monitored by HPLC. Results showed that oleuropein could be successfully converted into hydroxytyrosol. The most effective strain was Lactobacillus plantarum 6907, with a reaction yield of hydroxytyrosol of about 30 %. Different reaction mechanisms were observed for different microorganisms; a different yield was observed for Lactobacillus paracasei 9192 under aerobic or anaerobic conditions and an intermediate metabolite (oleuropein aglycone) was detected for Lactobacillus paracasei 9192 and Lactobacillus plantarum 6907 only. This study could have significant applications, as this reaction can be used to increase the value of olive oil by-products and/or to improve the taste of unripe olives.  相似文献   

13.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2±0.5 min and 8.0±0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at −70°C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

14.
A rapid, sensitive and reproducible high-performance liquid chromatographic assay for busulfan in human plasma was developed. After extraction of plasma samples with acetonitrile and methylene chloride, busulfan and the internal standard [1,5-bis(methanesulfonyloxy)pentane] were derivatized with 8-mercaptoquinoline to yield fluorescent compounds which were detected with a fluorescence detector equipped with filters of 360 nm (excitation) and 425 nm (emission). Calibration graphs showed a linear correlation (r>0.9990) over the concentration range of 20–2000 ng/ml. The recovery of busulfan from plasma standards was 70±5%. The detection and quantification limits for busulfan in plasma samples were established at 9 ng/ml and 20 ng/ml, respectively. The intra- and inter-assay variations were lower than 8% and 10%, respectively. The applicability of the method was verified by analyzing the plasma concentrations of busulfan in a patient to whom it was administered orally on two different days.  相似文献   

15.
A sensitive high-performance liquid chromatographic method is described for the quantification of midazolam and 1′-hydroxymidazolam in human plasma. Sample (1 ml plasma) preparation involved a simple solvent extraction step with a recovery of approximately 90% for both compounds. An aliquot of the dissolved residue was injected onto a 3 μm capillary C18 column (150 mm×0.8 mm I.D.). A gradient elution was used. The initial mobile phase composition (phosphate buffer–acetonitrile, 65:35) was maintained during 16 min and was then changed linearly during a 1-min period to phosphate buffer–acetonitrile, 40:60. The flow-rate of the mobile phase was 16 μl/min and the eluate was monitored by UV detection. The limits of quantification for midazolam and 1′-hydroxymidazolam were 1 ng/ml and 0.5 ng/ml, respectively. The applicability of the method was demonstrated by studying the pharmacokinetics of midazolam, and its major metabolite 1′-hydroxymidazolam, in human volunteers following i.v. bolus administration of a subtherapeutic midazolam dose (40 μg/kg).  相似文献   

16.
《Phytomedicine》2014,21(11):1400-1405
The aim of this study was to determine whether hydroxytyrosol and oleuropein, the major phenols found in olives and olive oil, inhibit mast cell activation induced by immune and non-immune pathways. Purified peritoneal mast cells were preincubated in the presence of test compounds (hydroxytyrosol or oleuropein), before incubation with concanavalin A, compound 48/80 or calcium ionophore A23187. Dose–response and time-dependence studies were carried out. Comparative studies with sodium cromoglycate, a classical mast cell stabilizer, were also made. After incubation the supernatants and pellets were used to determine the β-hexosaminidase content by colorimetric reaction. The percentage of β-hexosaminidase release in each tube was calculated and taken as a measure of mast cell activation. Other samples of cell pellets were used for cell viability studies by the trypan blue dye exclusion test, or fixed for light and electron microscopy. Biochemical and morphological findings of the present study showed for the first time that hydroxytyrosol and oleuropein inhibit mast cell degranulation induced by both immune and non-immune pathways. These results suggest that olive phenols, particularly hydroxytyrosol and oleuropein, may provide insights into the development of useful tools for the prevention and treatment of mast cell-mediated disorders.  相似文献   

17.
A rapid, sensitive and accurate high-performance liquid chromatographic method with UV detection was developed and validated for the quantification of gabapentin in human plasma. Gabapentin was quantified using pre-column derivatization with 1-fluoro-2,4-dinitrobenzene following protein precipitation of plasma with acetonitrile. Amlodipine was used as internal standard. The chromatographic separation was carried out on a Nova-Pak C(18) column using a mixture of 50 mM NaH(2)PO(4) (pH=2.5)-acetonitrile (30:70, v/v) as mobile phase with UV detection at 360 nm. The flow rate was set at 1.5 ml/min. The method was linear over the range of 0.05-5 microg/ml of gabapentin in plasma (r(2)>0.999). The within-day and between-day precision values were in the range of 2-5%. The limit of quantification of the method was 0.05 microg/ml. The method was successfully used to study the pharmacokinetics of gabapentin in healthy volunteers.  相似文献   

18.
A sensitive and specific liquid chromatography-tandem mass spectrometry assay was developed to quantify the first selective aldosterone blocker Eplerenone (I) and its hydrolyzed metabolite (II) in human plasma. The analytes (I, II) and their stable isotope-labeled analogues as internal standards were extracted on a C(18) solid-phase extraction cartridge using a Zymark RapidTrace automation system. The chromatographic separation was carried out on a narrow-bore reversed-phase Zorbax XDB-C(8) HPLC column with a mobile phase of acetonitrile/water (40:60, v/v) containing 10 mM ammonium acetate (pH 7.4). The analytes were ionized using negative-to-positive switch electrospray mass spectrometry, then detected by multiple reaction monitoring with a tandem mass spectrometer. The precursor to product ion transitions of m/z 415-->163 and m/z 431-->337 was used to measure I and II, respectively. The assay exhibited a linear dynamic range of 10-2500 ng/ml of plasma for both I and II. The lower limit of quantification was 10 ng/ml for I and II. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A throughput of 80 human plasma standards and samples per run was achieved with run time of 5 min for each injection. The assay has been successfully used in analyses of human plasma samples to support clinical studies.  相似文献   

19.
A sensitive and selective high-performance liquid chromatographic method for the simultaneous determination of a new angiotensin II receptor blocking agent, losartan (DuP 753, MK-954, I), and its active metabolite, EXP3174 (II), in human plasma or urine is described. The two analytes and internal standard are extracted from plasma and urine at pH 2.5 by liquid—liquid extraction and analyzed on a cyano column with ultraviolet detection at 254 nm. The mobile phase is composed of acetonitrile and phosphate buffer at pH 2.5. The limit of quantification for both compounds in plasma is 5 ng/ml. The limit in urine is 20 and 10 ng/ml for I and II, respectively. The assay described has been successfully applied to samples from pharmacokinetic studies.  相似文献   

20.
A simple and sensitive high-performance liquid chromatographic method was developed for the simultaneous determination of dihydromyricetin (1) and myricetin (2) in rat plasma after orally administrating the decoction of Ampelopsis grossedentata. Plasma samples were acidified with 0.375% phosphoric acid and extracted with ethyl acetate. Analysis of the extract was performed on reversed-phase C(18) column with a gradient eluent composed of acetonitrile and 0.04% phosphoric acid. The flow rate was kept at 1 ml/min and the detection wavelength was set at 290 and 370 nm for 1 and 2, respectively. The calibration curves were linear in the range of 0.247-4.114 microg/ml and 0.150-2.501 microg/ml for 1 and 2, respectively. The intra-day and inter-day precisions were better than 4.9 and 6.2%, respectively. The limits of detection (LOD) for 1 and 2 in plasma were 21.600 and 52.530 ng/ml, and the limits of quantification (LOQ) were 0.247 and 0.150 microg/ml, respectively. The mean recoveries for 1 and 2 were 92.0 and 93.3%, respectively. The accuracy and precision were well within the acceptable range and R.S.D. of measured rat samples was less than 7.5%. This validated method has been successfully applied in the pharmacokinetics study of dihydromyricetin and myricetin in vivo after orally administrating the decoction of A. grossedentata to rats.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号