首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Aims: To compare the standard culture method with a new, rapid test (ScanVIT‐Legionella?) using fluorescently labelled gene probes for the detection and enumeration of Legionella spp. The new technique was validated through experiments conducted on both artificially and naturally contaminated water and through an inter‐laboratory comparison. Methods and Results: All samples were processed by the ScanVIT test according to the manufacturer’s instructions and by a culture method (ISO 11731). ScanVIT detected significantly more positive samples, although concentrations were similar and a strong positive correlation between the two methods was observed (r = 0·888, P < 0·001). The new test was more accurate in identifying the co‐presence of Legionella pneumophila and Leg. non‐pneumophila. ScanVIT showed a slightly higher Legionella recovery from water samples artificially contaminated with Leg. pneumophila alone or together with Pseudomonas aeruginosa. Lastly, the inter‐laboratory comparison revealed that the ScanVIT test exhibits a lower variability than the traditional culture test (mean coefficient of variation 8·7 vs 16·1%). Conclusions: The results confirmed that the ScanVIT largely overlaps the reference method and offers advantages in terms of sensitivity, quantitative reliability and reduced assay time. Significance and Impact of the Study: The proposed method may represent a useful validated alternative to traditional culture for the rapid detection and quantification of Legionella spp. in water.  相似文献   

2.
We developed a rapid detection method for Legionella pneumophila (Lp) by filtration, immunomagnetic separation, double fluorescent staining, and flow cytometry (IMS‐FCM method). The method requires 120 min and can discriminate ‘viable’ and ‘membrane‐damaged’ cells. The recovery is over 85% of spiked Lp SG 1 cells in 1 l of tap water and detection limits are around 50 and 15 cells per litre for total and viable Lp, respectively. The method was compared using water samples from house installations in a blind study with three environmental laboratories performing the ISO 11731 plating method. In 53% of the water samples from different taps and showers significantly higher concentrations of Lp were detected by flow cytometry. No correlation to the plate culture method was found. Since also ‘viable but not culturable’ (VNBC) cells are detected by our method, this result was expected. The IMS‐FCM method is limited by the specificity of the used antibodies; in the presented case they target Lp serogroups 1–12. This and the fact that no Lp‐containing amoebae are detected may explain why in 21% of all samples higher counts were observed using the plate culture method. Though the IMS‐FCM method is not yet fit to completely displace the established plating method (ISO 11731) for routine Lp monitoring, it has major advantages to plating and can quickly provide important insights into the ecology of this pathogen in water distribution systems.  相似文献   

3.
Aims: Open cooling towers are frequent sources of infections with Legionella pneumophila. The gold standard for the detection of Leg. pneumophila is based on cultivation lasting up to 10 days and detecting only culturable cells. Alternative fluorescence in situ hybridization (FISH) protocols have been proposed, but they result in faint fluorescence signals and lack specificity because of cross‐hybridization with other Legionella species. Our aim was thus to develop a new FISH protocol for rapid and specific detection of Leg. pneumophila in water samples. Methods and Results: A novel catalysed reporter deposition FISH (CARD‐FISH) protocol for the detection of Leg. pneumophila was developed, which significantly enhanced signal intensity as well as specificity of the probe through the use of a novel competitor probe. The developed protocol was compared with the culture method for monitoring the seasonal development of culturable and nonculturable Leg. pneumophila in two hospital cooling tower systems. Seasonal fluctuations of Leg. pneumophila concentrations detected via CARD‐FISH were related to the development of the total bacterial community in both cooling towers, with temperature and biocide as the main factors controlling this development. Conclusions: Our results clearly showed that the majority of the Leg. pneumophila cells were in a nonculturable state. Thus, detection of Leg. pneumophila with culture methods may underestimate the total numbers of Leg. pneumophila present. Significance and Impact of the Study: Rapid, sensitive and specific detection and quantification of Leg. pneumophila in water systems is prerequisite for reliable risk estimation. The new protocol significantly improves current methodology and can be used to monitor and screen for Leg. pneumophila concentrations in cooling towers or other water systems.  相似文献   

4.
Aims: To optimize ethidium monoazide (EMA) coupled with real‐time quantitative PCR (qPCR) and to evaluate its environmental applicability on quantifying viable legionellae in water and biofilm of cooling towers and hot water systems. Methods and Results: EMA (0·9–45·5 μg ml?1) and propidium monoazide (PMA, 0·9 and 2·3 μg ml?1) combined with qPCR (i.e. EMA‐qPCR and PMA‐qPCR, respectively) were applied to unheated and heated (70°C for 30 min) Legionella pneumophila to quantify viable cells, which was also simultaneously determined by BacLight Bacterial Viability kit with epifluorogenic microscopic enumeration (BacLight‐EM). The effects of nontarget microflora and sample matrix on the performance of EMA‐qPCR were also evaluated. In comparison with BacLight‐EM results, qPCR with EMA at 2·3 μg ml?1 was determined as the optimal EMA‐qPCR assay, which performed equally well as PMA‐qPCR for unheated Leg. pneumophila but better than PMA‐qPCR for heated Leg. pneumophila (P < 0·05). Moreover, qPCR with EMA at 2·3 μg ml?1 accurately quantified viable Leg. pneumophila, Legionella anisa and Legionella‐like amoebal pathogens 6 (LLAP 6) without interferences by heated legionellae, unheated nonlegionellae cells and cooling tower water matrix (P > 0·05). As for water and biofilm samples collected from cooling towers and hot water systems, the viable legionellae counts determined by EMA‐qPCR were mostly greater than the culturable counts by culture assay but consistently lower than the total cell counts quantified by qPCR. Conclusions: The qPCR with EMA at 2·3 μg ml?1 may accurately quantify viable legionellae (including fastidious LLAP 6) and Leg. pneumophila pretreated with superheating and is applicable for water and biofilm samples obtained from cooling towers and hot water systems. Significance and Impact of the Study: The EMA‐qPCR assay may be useful in environmental surveillance for viable legionellae and in evaluation of superheating efficacy against legionellae.  相似文献   

5.
A new method for the rapid and sensitive detection of Legionella pneumophila in hot water systems has been developed. The method is based on an IF assay combined with detection by solid-phase cytometry. This method allowed the enumeration of L. pneumophila serogroup 1 and L. pneumophila serogroups 2 to 6, 8 to 10, and 12 to 15 in tap water samples within 3 to 4 h. The sensitivity of the method was between 10 and 100 bacteria per liter and was principally limited by the filtration capacity of membranes. The specificity of the antibody was evaluated against 15 non-Legionella strains, and no cross-reactivity was observed. When the method was applied to natural waters, direct counts of L. pneumophila were compared with the number of CFU obtained by the standard culture method. Direct counts were always higher than culturable counts, and the ratio between the two methods ranged from 1.4 to 325. Solid-phase cytometry offers a fast and sensitive alternative to the culture method for L. pneumophila screening in hot water systems.  相似文献   

6.
Aims: Legionella isolation from environmental samples is often difficult because of the presence of heterotrophic‐associated bacteria that frequently overgrow when using standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods. To improve Legionella pneumophila recovery from complex water samples (water from cooling towers, biofilms), we evaluated an immunomagnetic separation (IMS) assay using a monoclonal antibody raised against the lipopolysaccharide of Leg. pneumophila sg1 in combination with culture. Methods and Results: This study was conducted on 51 environmental specimens. The comparison between IMS‐culture and standard culture (ISO 11731, 1998; NF T90‐431, 2003) methods was made using ISO 17994, 2004 criteria for establishing equivalence between microbiological methods based on the upper and lower (XH and XL) values of the relative difference (95% confidence limit) and D as maximum acceptable deviation (value of the confidence limit). Conclusions: We found that the average performance of IMS culture was higher than the reference method. Significance and Impact of the Study: Thus, this IMS‐culture assay is particularly well adapted to the detection of Leg. pneumophila sg1 in environmental samples with high levels of interfering microflora.  相似文献   

7.

Aims

This study developed and systematically evaluated performance and limit of detection of an off‐the‐slide genotyping procedure for both Cryptosporidium oocysts and Giardia cysts.

Methods and Results

Slide standards containing flow‐sorted (oo)cysts were used to evaluate the off‐the‐slide genotyping procedure by microscopy and PCR. Results show approximately 20% of cysts and oocysts are lost during staining. Although transfer efficiency from the slide to the PCR tube could not be determined by microscopy, it was observed that the transfer process aided in the physical lysis of the (oo)cysts likely releasing DNA. PCR detection rates for a single event on a slide were 44% for Giardia and 27% for Cryptosporidium, and a minimum of five cysts and 20 oocysts are required to achieve a 90% PCR detection rate. A Poisson distribution analysis estimated the relative PCR target densities and limits of detection, it showed that 18 Cryptosporidium and five Giardia replicates are required for a 95% probability of detecting a single (oo)cyst on a slide.

Conclusions

This study successfully developed and evaluated recovery rates and limits of detection of an off‐the‐slide genotyping procedure for both Cryptosporidium and Giardia (oo)cysts from the same slide.

Significance and Impact of the Study

This off‐the‐slide genotyping technique is a simple and low cost tool that expands the applications of US EPA Method 1623 results by identifying the genotypes and assemblages of the enumerated Cryptosporidium and Giardia. This additional information will be useful for microbial risk assessment models and watershed management decisions.  相似文献   

8.
Propidium monoazide is a DNA‐intercalating dye. PMA‐qPCR has been reported as a novel method to detect live bacteria in complex samples. In this study, this method was used to monitor the sterilization effects of UHP, ultrasound and high PEF on Escherichia coli O157:H7. Our results showed that all three sterilization techniques are successful to kill viable E. coli O157:H7 cells under their appropriate conditions. PMA‐qPCR can effectively monitor the amount of DNA released from viable E. coli O157:H7 cells, and the results from PMA‐qPCR were highly consistent with those from plate counting after treatment with UHP, ultrasound and high PEF. The maximal ΔCt between PMA‐qPCR and qPCR obtained in this study was 10·39 for UHP, 5·76 for ultrasound and 2·30 for high PEF. The maximal sterilization rates monitored by PMA‐qPCR were 99·92% for UHP, 99·99% for ultrasound and 100% for high PEF. Thus, PMA‐qPCR can be used to detect the sterilization effect on food and water supplies after treatment with UHP, ultrasound and high PEF.

Significance and Impact of the Study

The reliable detection of viable foodborne pathogenic bacteria in water and food is of great importance in our daily life. However, the traditional bacteria cultivation‐based methods are time‐consuming and difficult to monitor all viable bacteria because of the limitation of cultivation conditions. This study demonstrated that PMA‐qPCR technique is very effective to monitor viable E. coli O157:H7 after sterilization and will help to monitor the viable bacteria in food and water.  相似文献   

9.
Aims: This study was designed to define the extent of water contamination by Legionella pneumophila of certain Italian hotels and to compare quantitative real‐time PCR with the conventional culture method. Methods and Results: Nineteen Italian hotels of different sizes were investigated. In each hotel three hot water samples (boiler, room showers, recycling) and one cold water sample (inlet) were collected. Physico‐chemical parameters were also analysed. Legionella pneumophila was detected in 42% and 74% of the hotels investigated by the culture method and by real‐time PCR, respectively. In 21% of samples analysed by the culture method, a concentration of >104 CFU l?1 was found, and Leg. pneumophila serogroup 1 was isolated from 10·5% of the hotels. The presence of Leg. pneumophila was significantly influenced by water sample temperature, while no association with water hardness or residual‐free chlorine was found. Conclusions: This study showed a high percentage of buildings colonized by Leg. pneumophila. Moreover, real‐time PCR proved to be sensitive enough to detect lower levels of contamination than the culture method. Significance and Impact of the Study: This study indicates that the Italian hotels represent a possible source of risk for Legionnaires’ disease and confirms the sensitivity of the molecular method. To our knowledge, this is the first report to demonstrate Legionella contamination in Italian hotels using real‐time PCR and culture methods.  相似文献   

10.

Aims

A Portable Multi‐use Automated Concentration System (PMACS) concentrates micro‐organisms from large volumes of water through automated dead‐end ultrafiltration and backflushing. The ability to detect microbial targets from ground, surface and cooling tower waters collected using standard methods was compared with samples from the PMACS in this study.

Methods and Results

PMACS (100 l) and standard grab samples (100–500 ml) were collected from sites in Florida and South Carolina, USA. Samples were analysed for the presence of faecal indicator bacteria (FIB; ground and surface water) or Legionella pneumophila (Lp; cooling tower water). FIB were enumerated by growth on selective media following membrane filtration or in IDEXX defined substrate media. Lp cells were detected by direct fluorescence immunoassay using FITC‐labelled monoclonal antibodies targeting serogroups 1, 2, 4 and 6. FIB were found in PMACS samples from ground and surface waters when their concentrations were below detection limits in grab samples. The concentrations of Lp in cooling tower samples collected over 5 months were more consistent in PMACS samples than grab samples.

Conclusions

These data demonstrate that PMACS concentration is advantageous for water monitoring. FIB were detected in PMACS samples when their concentrations were below the detection limits of the standard methods used. PMACS processing provided more representative samples of cooling tower waters reducing sample variability during long‐term monitoring.

Significance and Impact of the Study

This study highlights the utility of PMACS processing for enhanced monitoring of water for low‐level microbial targets and for reducing sample variability in long‐term monitoring programmes.  相似文献   

11.
The detection and quantification of Legionella pneumophila (responsible for legionnaire's disease) in water samples can be achieved by various methods. However, the culture-based ISO 11731:2017, which is based on counts of colony-forming units per ml (CFU·ml-1) is still the gold standard for quantification of Legionella species (spp.). As a powerful alternative, we propose real-time monitoring of the growth of Lpneumophila using an isothermal microcalorimeter (IMC). Our results demonstrate that, depending on the initial concentration of L. pneumophila, detection times of 24–48 h can be reliably achieved. IMC may, therefore, be used as an early warning system for L. pneumophila contamination. By replacing only visual detection of growth by a thermal sensor, but otherwise maintaining the standardized protocol of the ISO 11731:2017, the new procedure could easily be incorporated into existing standards. The exact determination of the beginning of metabolic heat is often very difficult because at the beginning of the calorimetric signal the thermal stabilization and the metabolic heat development overlap. Here, we propose a new data evaluation based on the first derivation of the heat flow signal. The improved evaluation method can further reduce detection times and significantly increase the reliability of the IMC approach.  相似文献   

12.
Legionella bacteria are ubiquitous in aquatic environments. Members of the species Legionella pneumophila are responsible for more than 98% of cases of Legionnaires' disease in France. Our objective was to validate a molecular typing method called infrequent restriction site PCR (IRS PCR), applied to the study of the ecology of Legionella and to compare this method with reference typing methods, pulsed‐field gel electrophoresis (PFGE) and sequence‐based Typing (SBT). PFGE and SBT are considered as gold methods for the epidemiological typing of Leg. pneumophila strains. However, these methods are not suitable to an ecological monitoring of Legionella in natural environments where a large number of strains has to be typed. Validation of IRS PCR method was performed by the identification of 45 Leg. pneumophila isolates from cooling circuits of thermal power plants by IRS PCR, PFGE and SBT. The parameters of each method were measured and compared to evaluate the effectiveness of IRS PCR. The results of this study showed that IRS PCR has a discriminating power similar or better than that of the reference methods and thus that, by its speed and low cost represents an appropriate tool for the study of the ecology of Legionella in cooling circuits.  相似文献   

13.

Aims

The objective of this study was to obtain a phenotypic and genotypic profile of Salmonella enterica including multidrug‐resistant (MDR) isolates from food‐producing animals and clinical isolates, as well as their genetic relatedness in two different States of Mexico (Jalisco and State of Mexico).

Methods and Results

A total of 243 isolates were evaluated in terms of antimicrobial resistance (AMR) and related genes through a disk diffusion method and PCR respectively; we found 16 MDR isolates, all of them harbouring the blaCMY gene but not qnr genes, these isolates represent less than 10% of the collection. The pulsed‐field gel electrophoresis revealed a higher genotypic similitude within isolates of State of Mexico than Jalisco.

Conclusions

A low percentage of Salmonella isolates were resistant to relevant antibiotics in human health, nevertheless, the AMR and involved genes were similar despite the different serovars and origin of the isolates.

Significance and Impact of the Study

This investigation provided an insight of the current status of AMR of Salmonella isolates in two States of Mexico and pinpoint the genes involved in AMR and their epidemiological relationship, the information could help to determine an adequate therapy in human and veterinary medicine.  相似文献   

14.
15.

Aims

Non‐Tuberculous Mycobacteria (NTM) are ubiquitous in nature. The data on prevalence of NTM under the RNTCP is scarce. Many NTM species have clinical significance, and hence their identification and speciation are important.

Methods and Results

It is a cross‐sectional study conducted at the five RNTCP accredited culture and drug susceptibility testing (CDST) laboratory. The culture isolates from AFB positive but Immunochromatographic test negative samples were taken for identification and speciation using HPLC. Of the total 266 isolates only 164 isolates had a second sample received at the laboratory. The speciation was done using HPLC for those isolates. The type of species identified are: 26·8% (44) were Mycobacterium chelonae, 12·8% (21) were Mycobacterium fortuitum, 9% (15) were Mycobacterium gordonae, 9% (15) were Mycobacterium tuberculosis complex, 6·1% (10) were Mycobacterium kansasii, 4·9% (8) were Mycobacterium simiae, 2·4% (4) were Mycobacterium thermophile, 1·2% (2) were Mycobacterium gastri, 0·6% (1) were Mycobacterium scrofulaceum, 0·6% (1) were Mycobacterium avium and 4·9% (8) isolates had chromatogram which was un‐interpretable.

Conclusion

Identification and its speciation of NTM are not routinely done under TB control programme. Since HPLC could identify 95% of isolates belonging to 10 species, the speciation of NTM using HPLC should gain importance in the diagnosis of disease caused by NTM.

Significance and Impact of Study

NTM are emerging as important causative agents of pulmonary and extra pulmonary disease, the ability to recognize disease caused by NTM and subsequently treat such disease has become increasingly important. The identification of NTM up to its species level should gain importance in all TB reference Laboratories.  相似文献   

16.

Aims

Enterocytozoon hepatopenaei is an emerging microsporidian parasite that has been linked to recent losses caused by white faeces syndrome (WFS) in cultivated giant or black tiger shrimp Penaeus (Penaeus) monodon and whiteleg shrimp Penaeus (Litopenaeus) vannamei in Asia. To more accurately assess its impact on shrimp production and to determine reservoir carriers for control measures, our objective was to establish a loop‐mediated isothermal amplification (LAMP) assay combined with colorimetric nanogold (AuNP) for rapid, sensitive and inexpensive detection of this parasite.

Methods and Results

A set of six specific primers was designed to successfully detect the SSU rRNA gene of E. hepatopenaei by a LAMP reaction of 45 min at 65°C combined with visual detection of the amplification product via hybridization at 65°C for 5 min with a ssDNA‐labelled nanogold probe, followed by salt‐induced AuNP aggregation (total assay time, approximately 50 min). This method gave similar results to LAMP followed by electrophoresis or spectrophotometric detection, and it was more sensitive (0·02 fg total DNA) than a conventional nested PCR (0·2 fg total DNA). The new method gave negative results with shrimp DNA templates extracted from diseased shrimp containing other pathogens, indicating that the LAMP‐AuNP assay was specific for E. hepatopenaei.

Conclusions

Without sacrificing sensitivity or specificity, the new LAMP‐AuNP assay significantly reduced the time, ease and cost for molecular detection of E. hepatopenaei in shrimp.

Significance and Impact of the study

The new method employs simple, inexpensive equipment and involves simple steps making it applicable for small field laboratories. Wider application of the method to screen broodstock before use in a hatchery, to screen postlarvae before stocking shrimp ponds, to test for natural carriers and to monitor shrimp in rearing ponds would help to assess and reduce the negative impact of this parasite in shrimp farming.  相似文献   

17.
A sensitive and specific method has been developed to enumerate viable L. pneumophila and other Legionella spp. in water by epifluorescence microscopy in a short period of time (a few hours). This method allows the quantification of L. pneumophila or other Legionella spp. as well as the discrimination between viable and nonviable Legionella. It simultaneously combines the specific detection of Legionella cells using antibodies and a bacterial viability marker (ChemChrome V6), the enumeration being achieved by epifluorescence microscopy. The performance of this immunological double-staining (IDS) method was investigated in 38 natural filterable water samples from different aquatic sources, and the viable Legionella counts were compared with those obtained by the standard culture method. The recovery rate of the IDS method is similar to, or higher than, that of the conventional culture method. Under our experimental conditions, the limit of detection of the IDS method was <176 Legionella cells per liter. The examination of several samples in duplicates for the presence of L. pneumophila and other Legionella spp. indicated that the IDS method exhibits an excellent intralaboratory reproducibility, better than that of the standard culture method. This immunological approach allows rapid measurements in emergency situations, such as monitoring the efficacy of disinfection shock treatments. Although its field of application is as yet limited to filterable waters, the double-staining method may be an interesting alternative (not equivalent) to the conventional standard culture methods for enumerating viable Legionella when rapid detection is required.  相似文献   

18.

Background

The aims of this study were to develop and validate a multiplex real‐time polymerase chain reaction (q‐PCR) assay of Helicobacter pylori in stool samples of healthy children. Additionally, we determined the prevalence of clarithromycin resistance and cagA gene in H. pylori‐positive samples.

Materials and methods

Archived stool samples from 188 children aged 6‐9 years and 272 samples of 92 infants aged 2‐18 months were tested for H. pylori antigens using enzyme immunoassay (EIA). A multiplex q‐PCR assay was designed to detect H. pylori 16S rRNA and urease and the human RNase P gene as an internal control. Kappa coefficient was calculated to assess the agreement between q‐PCR and EIA.

Results

Laboratory validation of the q‐PCR assay using quantitated H. pylori ATCC 43504 extracted DNA showed S‐shaped amplification curves for all genes; the limit of detection was 1 CFU/reaction. No cross‐reactivity with other bacterial pathogens was noted. Applying the multiplex q‐PCR to DNA extracted from fecal samples showed clear amplification curves for urease gene, but not for 16S rRNA. The prevalence of H. pylori infection was 50% (95% CI 43%‐57%) by q‐PCR (urease cycle threshold <44) vs 59% (95% CI 52%‐66%) by EIA. Kappa coefficient was .80 (P < .001) and .44 (P < .001) for children aged 6‐9 years and 2‐18 months, respectively. Sixteen samples were positive for cagA and three were positive for clarithromycin resistance mutation (A2143G) as confirmed by sequencing.

Conclusions

The developed q‐PCR can be used as a cotechnique to enhance the accuracy of H. pylori detection in epidemiological studies and in clinical settings.  相似文献   

19.
Quantification of fatty acids has been crucial to elucidate lipid biosynthesis pathways in plants. To date, fatty acid identification and quantification has relied mainly on gas chromatography (GC) coupled to flame ionization detection (FID) or mass spectrometry (MS), which requires the derivatization of samples and the use of chemical standards for annotation. Here we present an alternative method based on a simple procedure for the hydrolysis of lipids, so that fatty acids can be quantified by liquid chromatography mass spectrometry (LC‐MS) analysis. Proper peak annotation of the fatty acids in the LC‐MS‐based methods has been achieved by LC‐MS measurements of authentic standard compounds and elemental formula annotation supported by 13C isotope‐labeled Arabidopsis. As a proof of concept, we have compared the analysis by LC‐MS and GC‐FID of two previously characterized Arabidopsis thaliana knock‐out mutants for FAD6 and FAD7 desaturase genes. These results are discussed in light of lipidomic profiles obtained from the same samples. In addition, we performed untargeted LC‐MS analysis to determine the fatty acid content of two diatom species. Our results indicate that both LC‐MS and GC‐FID analyses are comparable, but that because of higher sensitivity and selectivity the LC‐MS‐based method allows for a broader coverage and determination of novel fatty acids.  相似文献   

20.
Phytophthora nicotianae is a phytopathogenic oomycete with a wide host range and worldwide distribution. Rapid detection and diagnosis at the early stages of disease development are important for the effective control of P. nicotianae. In this study, we designed a simple and rapid loop‐mediated isothermal amplification (LAMP)‐based detection method for P. nicotianae. We tested three DNA extraction methods and selected the Kaneka Easy DNA Extraction Kit version 2, which is rapid and robust for LAMP‐based detection. The designed primers were tested using mycelial DNA from 35 species (81 isolates) of Phytophthora, 12 species (12 isolates) of Pythium, one isolate of Phytopythium and one isolate each from seven other soil‐borne pathogens. All of the 42 P. nicotianae isolates were detected by these primers, and no other isolates gave positive results. Three isolates were tested for the sensitivity of the reaction, and the lowest amounts of template DNA that could be detected were 10 fg for two isolates and 1 fg for the third. The target was detected within 25 min in all tested samples, including DNA extracted from both inoculated and naturally infected plants. In contrast, PCR assays with P. nicotianae‐specific primers failed or showed weakened detection in several samples. Thus, we found that the rapid DNA extraction and LAMP assay methods developed in this study can be used to detect P. nicotianae with high sensitivity, specificity and stability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号