首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Diketopyrrolopyrrole (DPP)‐conjugated polymers are a versatile class of semiconductors for application in organic solar cells because of their tunable optoelectronic properties. A record power conversion efficiency (PCE) of 9.4% was recently achieved for DPP polymers, but further improvements are required to reach true efficiency limits. Using five DPP polymers with different chemical structures and molecular weights, the device performance of polymer:fullerene solar cells is systematically optimized by considering device polarity, morphology, and light absorption. The polymer solubility is found to have a significant effect on the optimal device polarity. Soluble polymers show a 10–25% increase in PCE in inverted device configurations, while the device performance is independent of device polarity for less soluble DPP derivatives. The difference seems related to the polymer to fullerene weight ratio at the ZnO interface in inverted devices, which is higher for more soluble DPP polymers. Optimization of the nature of the cosolvent to narrow the fibril width of polymers in the blends toward the exciton diffusion length enhances charge generation. Additionally, the use of a retroreflective foil increases absorption of light. Combined, the effects afford a PCE of 9.6%, among the highest for DPP‐based polymer solar cells.  相似文献   

2.
In situ electroporation of adherent cells provides significant advantages with respect to electroporation systems for suspension cells, such as causing minimal stress to cultured cells and simplifying and saving several steps within the process. In this study, a new electrode assembly design is shown and applied to in situ electroporate adherent cell lines growing in standard multiwell plates. We designed an interdigitated array of electrodes patterned on copper with printed circuit board technology and covered with nickel/gold. Small interelectrode distances were used to achieve effective electroporation with low voltages. Epoxy-based microseparators were constructed to avoid direct contact with the cells and to create more uniform electric fields. The device was successful in the electropermeabilization of two different adherent cell lines, C2C12 and HEK 293, as assessed by the intracellular delivery of the fluorescent dextran FD20S. Additionally, as a collateral effect, we observed cell electrofusion in HEK 293 cells, thus making this device also useful for performing cell fusion. In summary, we show the effectiveness of this minimally invasive device for electroporation of adherent cells cultured in standard multiwell plates. The cheap technologies used in the fabrication process of the electrode assembly indicate potential use as a low-cost, disposable device.  相似文献   

3.
4.
An energy efficient electromagnetic stimulator device for fracture healing was compared to a commercially available device in stimulating cell growth in tissue cultures. The energy efficient device, which conserves energy by using a bidirectional time-dependent magnetic wave form, and the commercially available stimulator, which uses a unidirectionaltime-dependent magnetic wave form, were tested on chick tendon fibroblasts in primary culture. Comparing non-stimulated control and cells electromagnetically stimulated with unidirectional and bidirectional waveforms showed that at the growth phase between days 2 and 3, both electrical stimulation techniques increased cell division as measured by DNA synthesis. When cells were dividing rapidly, collagen synthesis was reduced. When the cells reached the confluence there was no difference among the groups (control, unidirectionally stimulated, and bidirectionally stimulated) in terms of number of cells or collagen produced. © 1994 Wiley-Liss, Inc.  相似文献   

5.
This paper presents a method and a device to position and displace cells. The cells are suspended in a fluid layer trapped between the device and an arbitrary surface such as an object slide or a wafer. The device vibrates at ultrasonic frequencies causing a pressure field in the fluid layer. This pressure field results in a force-field capable of positioning cells. Depending on the way in which the device is excited a 2-D or 3-D force-field can be generated, positioning the cells in lines or points respectively. Furthermore, it is possible to subsequently displace the cells with micrometer accuracy. This has been demonstrated using HL60 and MCF10A cells, and can be achieved without causing damage to the cells.  相似文献   

6.
Identifying tumor cells from a pool of other cells has always been an appealing topic for different purposes. The objective of this study is to discriminate circulating tumor cells (CTCs) from blood cells for diagnostic purposes in a novel microfluidic device using two active methods: magnetophoresis and dielectrophoresis. The most specific feature of this device is the differentiation of CTCs without labeling them in order to achieve a more reliable and less complicated method. This device was analyzed and evaluated using finite element method. Four cell lines are separated in this device containing red blood cells, platelets, white blood cells, and CTCs. Primarily, red blood cells and platelets, which constitute the largest part of a blood sample, are removed in the magnetophoresis section. Remaining cells enter the dielectrophoresis part and based on their inherent dielectric properties and diameters, final separation occurs. In each step, different parameters are examined to obtain the maximum purification. The results demonstrate the potential of different CTCs separation by changing the effective parameters in the designed device based on the inherent properties of the cells.  相似文献   

7.
I Spadinger  S S Poon  B Palcic 《Cytometry》1990,11(4):460-467
The effect of defocusing on the quality of signals from live cells detected by an automated image cytometry device, the Cell Analyzer, was examined. The influence of these effects on the ability of this device to automatically locate cells plated into a tissue culture flask was then determined by measuring the performance of cell detection and recognition procedures as a function of focus setting. Acceptable limits for deviation from the optimal focus setting (as determined by microscope objective position) were found to be similar for both these procedures, ranging from 40 microns below to 25 microns above the optimal focus position. These limits were asymmetrical about ideal focus due to a pronounced asymmetry in the effects of positive and negative defocusing on the cell signal.  相似文献   

8.
An investigation was conducted of the parametric dependence of cell lysis observed when mammalian cells growing in suspension are subjected intermittently to intense hydrodynamic forces. Two flow devices were tested: one consisting of a sudden contraction into a short length of capillary tubing, in which turbulent flow is obtained, and another consisting of a smoothly converging and diverging tube, in which laminar flow is obtained. Changes in the cell line and the serum level in which the cells were grown and subjected to flow trauma both affected the specific lysis rate (fraction of cells lysed per pass through the flow device) in the turbulent flow device. The threshold value of the average wall shear stress level was approximately the same in the turbulent and laminar flow devices (1500–1800 dyn/cm2). Increasing the viscosity of the medium with 70,000 MW dextran had no effect on the specific lysis rate in either flow device.  相似文献   

9.
In this study we describe an original, efficient, and innovative printed circuit board (PCB) device able to generate dielectrophoresis-based, software-controlled cages that can be moved to any place inside a microchamber. Depending on their dielectrophoretic properties, eukaryotic cells can be "entrapped" in cages and moved under software control. The main conclusion gathered from the experimental data reported is that the PCB device based on dielectrophoresis permits levitation and movement of different tumor cells at different dielectrophoresis conditions. The results presented herein are therefore the basis for experiments aimed at forced interactions or separation of eukaryotic cells using "lab-on-a-chip." In fact, because many cages can be controlled at the same time, and two or more cages can be forced to share the same or a different location, it is possible, in principle, either to bring in contact cells of a differing histotype or to separate them.  相似文献   

10.
Many experimental models have been developed to investigate the effects of mechanical stimulation of cells, but none of the existing devices can simulate micromotions at the cellular-mechanical interface with varying amplitudes and loads. Osteoblasts are sensitive to mechanical stimuli, so to study the bone-implant interface it would be important to quantify their reaction in a situation mimicking the mechanical situation arising at that interface. In this study, we present the development of a new device allowing the application of micromotions and load on cells in vitro. The new device allowed the cells to be stimulated with sinusoidal motions of amplitudes comprised between +/- 5 and +/- 50 microm, frequencies between 0.5 and 2 Hz, and loads between 50 and 1000 Pa. The device, with a total length of 20 cm, was designed to work in an incubator at 37 degrees C and 100% humidity. Expression of various bone important genes was monitored by real-time RT-PCR. Micromotions and load were shown to affect the behavior of osteoblasts by down-regulating the expression of genes necessary for the creation of organic extracellular matrix (collagen type I) as well as for genes involved in the mineralization process (osteocalcin, osteonectin). The developed device could then be used to simulate different mechanical situations at the bone-implant interface.  相似文献   

11.
Intrauterine devices containing copper were introduced into cultures of adult and fetal cells. The Dalkon shield had no apparent effect on cell growth. The Gravigard device caused inhibition of growth and an increase in copper concentration in the supranatant medium. When the latter device was transferred through a series of subcultures the rate of release of copper decreased and growth was no longer inhibited.  相似文献   

12.
Mechanical forces exerted on cells and/or tissues play a major role in numerous processes. We have developed a device to stretch cells plated on a PolyDiMethylSiloxane (PDMS) membrane, compatible with imaging. This technique is reproducible and versatile. The PDMS membrane can be micropatterned in order to confine cells or tissues to a specific geometry. The first step is to print micropatterns onto the PDMS membrane with a deep UV technique. The PDMS membrane is then mounted on a mechanical stretcher. A chamber is bound on top of the membrane with biocompatible grease to allow gliding during the stretch. The cells are seeded and allowed to spread for several hours on the micropatterns. The sample can be stretched and unstretched multiple times with the use of a micrometric screw. It takes less than a minute to apply the stretch to its full extent (around 30%). The technique presented here does not include a motorized device, which is necessary for applying repeated stretch cycles quickly and/or computer controlled stretching, but this can be implemented. Stretching of cells or tissue can be of interest for questions related to cell forces, cell response to mechanical stress or tissue morphogenesis. This video presentation will show how to avoid typical problems that might arise when doing this type of seemingly simple experiment.  相似文献   

13.
A major limitation to yeast aging study has been the inability to track mother cells and observe molecular markers during the aging process. The traditional lifespan assay relies on manual micro-manipulation to remove daughter cells from the mother, which is laborious, time consuming, and does not allow long term tracking with high resolution microscopy. Recently, we have developed a microfluidic system capable of retaining mother cells in the microfluidic chambers while removing daughter cells automatically, making it possible to observe fluorescent reporters in single cells throughout their lifespan. Here we report the development of a new generation of microfluidic device that overcomes several limitations of the previous system, making it easier to fabricate and operate, and allowing functions not possible with the previous design. The basic unit of the device consists of microfluidic channels with pensile columns that can physically trap the mother cells while allowing the removal of daughter cells automatically by the flow of the fresh media. The whole microfluidic device contains multiple independent units operating in parallel, allowing simultaneous analysis of multiple strains. Using this system, we have reproduced the lifespan curves for the known long and short-lived mutants, demonstrating the power of the device for automated lifespan measurement. Following fluorescent reporters in single mother cells throughout their lifespan, we discovered a surprising change of expression of the translation elongation factor TEF2 during aging, suggesting altered translational control in aged mother cells. Utilizing the capability of the new device to trap mother-daughter pairs, we analyzed mother-daughter inheritance and found age dependent asymmetric partitioning of a general stress response reporter between mother and daughter cells.  相似文献   

14.
We observed that flowing helium at moderate pressures accelerated DNA-coated microprojectiles to velocities suitable for penetration of cells in intact plant tissues. The flowing helium principle permitted the construction of a simple and inexpensive transformation device that was easier to use than those previously described. This device provided efficient transformation of cells in soybean seedlings and other plants.  相似文献   

15.
Fibroblasts, the major cell type in tumor stroma, are essential for tumor growth and survival, and represent an important therapeutic target for cancers. Here we presented a microfluidic co-culture device in which the three-dimensional (3D) matrix was employed to reconstruct an in vivo-like fibroblast-tumor cell microenvironment for investigation of the role of myofibroblasts induced by lung cancer cells in the chemoresistance to VP-16. Composed of a double-layer chip and an injection pump, the device houses fibroblasts and lung cancer cells co-cultured in 3D matrix and 2D mode to induce fibroblasts to become myofibroblasts with the supplement of the medium continuously. With this device, we verified that the cytokines secreted by lung cancer cells could effectively transform the fibroblasts into myofibroblasts. Moreover, compared to fibroblasts, the myofibroblasts showed higher resistance to anticancer drug VP-16. We also demonstrated that this kind of acquired resistance in myofibroblasts was associated with the expression of Glucose-regulated protein 78 (GP78). We concluded that this device allows for the assay to characterize various cellular events in a single device sequentially, facilitating a better understanding of the interactions among heterotypic cells in a sophisticated microenvironment.  相似文献   

16.
Extravasation of circulating cells from the bloodstream plays a central role in many physiological and pathophysiological processes, including stem cell homing and tumor metastasis. The three-dimensional flow chamber device (hereafter the 3D device) is a novel in vitro technology that recreates physiological shear stress and allows each step of the cell extravasation cascade to be quantified. The 3D device consists of an upper compartment in which the cells of interest circulate under shear stress, and a lower compartment of static wells that contain the chemoattractants of interest. The two compartments are separated by porous inserts coated with a monolayer of endothelial cells (EC). An optional second insert with microenvironmental cells of interest can be placed immediately beneath the EC layer. A gas exchange unit allows the optimal CO2 tension to be maintained and provides an access point to add or withdraw cells or compounds during the experiment. The test cells circulate in the upper compartment at the desired shear stress (flow rate) controlled by a peristaltic pump. At the end of the experiment, the circulating and migrated cells are collected for further analyses. The 3D device can be used to examine cell rolling on and adhesion to EC under shear stress, transmigration in response to chemokine gradients, resistance to shear stress, cluster formation, and cell survival. In addition, the optional second insert allows the effects of crosstalk between EC and microenvironmental cells to be examined. The translational applications of the 3D device include testing of drug candidates that target cell migration and predicting the in vivo behavior of cells after intravenous injection. Thus, the novel 3D device is a versatile and inexpensive tool to study the molecular mechanisms that mediate cellular extravasation.  相似文献   

17.
The first solid‐state solar cells, fabricated ≈140 years ago, were based on selenium; these early studies initiated the modern research on photovoltaic materials. Selenium shows high absorption coefficient and mobility, making it an attractive absorber for high bandgap thin film solar cells. Moreover, the simplicity of a single element absorber, its low‐temperature processing, and intrinsic environmental stability enable the utilization of selenium in extremely cheap and scalable solar cells. In this paper, a detailed study of selenium solar cell fabrication is presented, and the key factors that affect the selenium film morphology and the resulting device efficiency are presented. Specifically, the crystallization process from amorphous film into functional crystalline device is studied. The importance of controlling the process is shown, and methods to align the growth orientation are suggested. Finally, the crystallization process under illumination, which has general importance for the fabrication of thin film photovoltaics, is investigated. Specifically for selenium, the illumination significantly improves the film morphology and leads to device efficiency of 5.2%, with open‐circuit voltage of 0.911 V, short‐circuit current density of 10.2 mA cm?2, and fill factor of 55.0%. These findings form a solid foundation for future improvements of the photovoltaic material and device architecture.  相似文献   

18.
The use of optical dielectrophoresis (ODEP) to manipulate microparticles and biological cells has become increasingly popular due to its tremendous flexibility in providing reconfigurable electrode patterns and flow channels. ODEP enables the parallel and free manipulation of small particles on a photoconductive surface on which light is projected, thus eliminating the need for complex electrode design and fabrication processes. In this paper, we demonstrate that mouse cells comprising melan-a cells, RAW 267.4 macrophage cells, peripheral white blood cells and lymphocytes, can be manipulated in an opto-electrokinetics (OEK) device with appropriate DEP parameters. Our OEK device generates a non-rotating electric field and exerts a localized DEP force on optical electrodes. Hitherto, we are the first group to report that among all the cells investigated, melan-a cells, lymphocytes and white blood cells were found to undergo self-rotation in the device in the presence of a DEP force. The rotational speed of the cells depended on the voltage and frequency applied and the cells'' distance from the optical center. We discuss a possible mechanism for explaining this new observation of induced self-rotation based on the physical properties of cells. We believe that this rotation phenomenon can be used to identify cell type and to elucidate the dielectric and physical properties of cells.  相似文献   

19.
In this report, a label-free reflectometric interference spectroscopy (RIfS) based microchip biosensor for the detection of circulating tumour cells (CTCs) is demonstrated. Highly ordered nanoporous anodic aluminium oxide (AAO) fabricated by electrochemical anodization of aluminium foil was used as the RIfS sensing platform. Biotinylated anti-EpCAM antibody that specifically binds to human cancer cells of epithelial origin such as pancreatic cancer cells (PANC-1) was covalently attached to the AAO surface through multiple surface functionalization steps. Whole blood or phosphate buffer saline spiked with low numbers of pancreatic cancer cells were successfully detected by specially designed microfluidic device incorporating an AAO RIfS sensor, without labour intensive fluorescence labelling and/or pre-enhancement process. Our results show that the developed device is capable of selectively detecting of cancer cells, within a concentrations range of 1000-100,000 cells/mL, with a detection limit of <1000 cells/mL, a response time of <5 min and sample volume of 50 μL of. The presented RIfS method shows considerable promise for translation to a rapid and cost-effective point-of-care diagnostic device for the detection of CTCs in patients with metastatic cancer.  相似文献   

20.
Invadopodia or invasive feet, which are actin-rich membrane protrusions with matrix degradation activity formed by invasive cancer cells, are a key determinant in the malignant invasive progression of tumors and represent an important target for cancer therapies. In this work, we presented a microfluidic 3D culture device with continuous supplement of fresh media via a syringe pump. The device mimicked tumor microenvironment in vivo and could be used to assay invadopodia formation and to study the mechanism of human lung cancer invasion. With this device, we investigated the effects of epidermal growth factor (EGF) and matrix metalloproteinase (MMP) inhibitor, GM6001 on invadopodia formation by human non-small cell lung cancer cell line A549 in 3D matrix model. This device was composed of three units that were capable of achieving the assays on one control group and two experimental groups'' cells, which were simultaneously pretreated with EGF or GM6001 in parallel. Immunofluorescence analysis of invadopodia formation and extracellular matrix degradation was conducted using confocal imaging system. We observed that EGF promoted invadopodia formation by A549 cells in 3D matrix and that GM6001 inhibited the process. These results demonstrated that epidermal growth factor receptor (EGFR) signaling played a significant role in invadopodia formation and related ECM degradation activity. Meanwhile, it was suggested that MMP inhibitor (GM6001) might be a powerful therapeutic agent targeting invadopodia formation in tumor invasion. This work clearly demonstrated that the microfluidic-based 3D culture device provided an applicable platform for elucidating the mechanism of cancer invasion and could be used in testing other anti-invasion agents.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号