首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Soft tissue artefacts (STA) are a major error source in skin marker-based measurement of human movement, and are difficult to eliminate non-invasively. The current study quantified in vivo the STA of skin markers on the thigh and shank during cycling, and studied the effects of knee angles and pedal resistance by using integrated 3D fluoroscopy and stereophotogrammetry. Fifteen young healthy adults performed stationary cycling with and without pedal resistance, while the marker data were measured using a motion capture system, and the motions of the femur and tibia/fibula were recorded using a bi-plane fluoroscopy-to-CT registration method. The STAs with respect to crank and knee angles over the pedaling cycle, as well as the within-cycle variations, were obtained and compared between resistance conditions. The thigh markers showed greater STA than the shank ones, the latter varying linearly with adjacent joint angles, the former non-linearly with greater within-cycle variability. Both STA magnitudes and within-cycle variability were significantly affected by pedal resistance (p < 0.05). The STAs appeared to be composed of one component providing the stable and consistent STA patterns and another causing their variations. Mid-segment markers experienced smaller STA ranges than those closer to a joint, but tended to have greater variations primarily associated with pedal resistance and muscle contractions. The current data will be helpful for a better choice of marker positions for data collection, and for developing methods to compensate for both stable and variation components of the STA.  相似文献   

2.
Biomechanics of the knee during stair-ascent has mostly been studied using skin-marker-based motion analysis techniques, but no study has reported a complete assessment of the soft tissue artifacts (STA) and their effects on the calculated joint center translation, angles and moments at the knee in normal subjects during this activity. This study aimed to bridge the gap. Twelve young adults walked up a three-step stair while data were acquired simultaneously from a three-dimensional motion capture system, a force plate and a dynamic fluoroscopy system. The "gold standards" of poses of the knee were obtained using a 3D fluoroscopy method. The STA of the markers on the thigh and shank were then calculated, together with their effects on the calculated joint center translations, angles and moments at the knee. The STA of the thigh markers were greater than those on the shank, leading to significantly underestimated flexion and extensor moments, but overestimated joint center translations during the first half of the stance phase. The results will be useful for a better understanding of the normal biomechanics of the knee during stair-ascent, as a baseline for future clinical applications and for developing a compensation method to correct for the effects of STA.  相似文献   

3.
The estimation of joint kinematics from skin markers is hindered by the soft tissue artefact (STA), a well-known phenomenon although not fully characterized. While most assessments of the STA have been performed based on the individual skin markers displacements, recent assessments were based on the marker-cluster geometrical transformations using, e.g., principal component or modal analysis. However, these marker-clusters were generally made of 4–6 markers and the current findings on the STA could have been biased by the limited number of skin makers analysed. The objective of the present study was therefore to confirm them with a high-density marker set, i.e. 40 markers placed on the segments.A larger number of modes than found in the literature was required to describe the STA. Nevertheless, translations and rotations of the marker-cluster remained the main STA modes, archetypally the translation along the proximal-distal and anterior-posterior axes for the shank and the translation along the proximal-distal axis and the rotation about the medial-lateral axis for the thigh. High correlations were also found between the knee flexion angle and the amplitude of these modes for the thigh whereas moderate ones were found for the shank.These findings support the current re-orientation of the STA compensation methods, from bone pose estimators which typically address the non-rigid components of the marker-cluster to kinematic-driven rigid-component STA models.  相似文献   

4.
To reduce the impact of the soft tissue artefact (STA) on the estimate of skeletal movement using stereophotogrammetric and skin-marker data, multi-body kinematics optimisation (MKO) and extended Kalman filters (EKF) have been proposed. This paper assessed the feasibility and efficiency of these methods when they embed a mathematical model of the STA and simultaneously estimate the ankle, knee and hip joint kinematics and the model parameters. A STA model was used that provides an estimate of the STA affecting the marker-cluster located on a body segment as a function of the kinematics of the adjacent joints. The MKO and the EKF were implemented with and without the STA model. To assess these methods, intra-cortical pin and skin markers located on the thigh, shank, and foot of three subjects and tracked during the stance phase of running were used. Embedding the STA model in MKO and EKF reduced the average RMS of marker tracking from 12.6 to 1.6 mm and from 4.3 to 1.9 mm, respectively, showing that a STA model trial-specific calibration is feasible. Nevertheless, with the STA model embedded in MKO, the RMS difference between the estimated and the reference joint kinematics determined from the pin markers slightly increased (from 2.0 to 2.1 deg) On the contrary, when the STA model was embedded in the EKF, this RMS difference was slightly reduced (from 2.0 to 1.7 deg) thus showing a better potentiality of this method to attenuate STA effects and improve the accuracy of joint kinematics estimate.  相似文献   

5.
We describe segment angles (trunk, thigh, shank, and foot) and joint angles (hip, knee, and ankle) for the hind limbs of bonobos walking bipedally ("bent-hip bent-knee walking," 17 sequences) and quadrupedally (33 sequences). Data were based on video recordings (50 Hz) of nine subjects in a lateral view, walking at voluntary speed. The major differences between bipedal and quadrupedal walking are found in the trunk, thigh, and hip angles. During bipedal walking, the trunk is approximately 33-41 degrees more erect than during quadrupedal locomotion, although it is considerably more bent forward than in normal human locomotion. Moreover, during bipedal walking, the hip has a smaller range of motion (by 12 degrees ) and is more extended (by 20-35 degrees ) than during quadrupedal walking. In general, angle profiles in bonobos are much more variable than in humans. Intralimb phase relationships of subsequent joint angles show that hip-knee coordination is similar for bipedal and quadrupedal walking, and resembles the human pattern. The coordination between knee and ankle differs much more from the human pattern. Based on joint angles observed throughout stance phase and on the estimation of functional leg length, an efficient inverted pendulum mechanism is not expected in bonobos.  相似文献   

6.
The position, in a pelvis-embedded anatomical coordinate system, of skin points located over the following anatomical landmarks (AL) was determined while the hip assumed different spatial postures: right and left anterior superior and posterior superior iliac spines, and the sacrum. Postures were selected as occurring during walking and during a flexion–extension and circumduction movement, as used to determine the hip joint centre position (star-arc movement). Five volunteers, characterised by a wide range of body mass indices (22–37), were investigated. Subject-specific MRI pelvis digital bone models were obtained. For each posture, the pose of the pelvis-embedded anatomical coordinate system was determined by registering this bone model with points digitised over bony prominences of the pelvis, using a wand carrying a marker-cluster and stereophotogrammetry. The knowledge of how the position of the skin points varies as a function of the hip posture provided information regarding the soft tissue artefact (STA) that would affect skin markers located over those points during stereophotogrammetric movement analysis. The STA was described in terms of amplitude (relative to the position of the AL during an orthostatic posture), diameter (distance between the positions of the AL which were farthest away from each other), and pelvis orientation. The STA amplitude, exhibited, over all postures, a median [inter-quartile] value of 9[6] and 16[11] mm, for normal and overweight volunteers, respectively. STA diameters were larger for the star-arc than for the walking postures, and the direction was predominantly upwards. Consequent errors in pelvic orientation were in the range 1–9 and 4–11 degrees, for the two groups respectively.  相似文献   

7.
Optoelectronic motion capture systems are widely employed to measure the movement of human joints. However, there can be a significant discrepancy between the data obtained by a motion capture system (MCS) and the actual movement of underlying bony structures, which is attributed to soft tissue artefact. In this paper, a computer-aided tracking and motion analysis with ultrasound (CAT & MAUS) system with an augmented globally optimal registration algorithm is presented to dynamically track the underlying bony structure during movement. The augmented registration part of CAT & MAUS was validated with a high system accuracy of 80%. The Euclidean distance between the marker-based bony landmark and the bony landmark tracked by CAT & MAUS was calculated to quantify the measurement error of an MCS caused by soft tissue artefact during movement. The average Euclidean distance between the target bony landmark measured by each of the CAT & MAUS system and the MCS alone varied from 8.32 mm to 16.87 mm in gait. This indicates the discrepancy between the MCS measured bony landmark and the actual underlying bony landmark. Moreover, Procrustes analysis was applied to demonstrate that CAT & MAUS reduces the deformation of the body segment shape modeled by markers during motion. The augmented CAT & MAUS system shows its potential to dynamically detect and locate actual underlying bony landmarks, which reduces the MCS measurement error caused by soft tissue artefact during movement.  相似文献   

8.
When measuring knee kinematics with skin-mounted markers, soft tissue and structures surrounding the knee hide the actual underlying segment kinematics. Soft-tissue artefacts can be reduced when plate-mounted markers or marker trees are used instead of individual unconstrained mounted markers. The purpose of this study was to accurately quantify the soft-tissue artefacts and to compare two marker cluster fixation methods by using fluoroscopy of knee motion after total knee arthroplasty during a step-up task. Ten subjects participated 6 months after their total knee arthroplasty. The patients were randomised into (1) a plate-mounted marker group and (2) a strap-mounted marker group. Fluoroscopic data were collected during a step-up motion. A three-dimensional model fitting technique was used to reconstruct the in vivo 3-D positions of the markers and the implants representing the bones. The measurement errors associated with the thigh were generally larger (maximum translational error: 17mm; maximum rotational error 12 degrees ) than the measurement errors for the lower leg (maximum translational error: 11mm; maximum rotational error 10 degrees ). The strap-mounted group showed significant more translational errors than the plate-mounted group for both the shank (respectively, 3+/-2.2 and 0+/-2.0mm, p = 0.025) and the thigh (2+/-2.0 and 0+/-5.9mm, p = 0.031). The qualitative conclusions based on interpretation of the calculated estimates of effects within the longitudinal mixed-effects modelling evaluation of the data for the two groups (separately) were effectively identical. The soft-tissue artefacts across knee flexion angle could not be distinguished from zero for both groups. For all cases, recorded soft-tissue artefacts were less variable within subjects than between subjects. The large soft-tissue artefacts, when using clustered skin markers, irrespective of the fixation method, question the usefulness of parameters found with external movement registration and clinical interpretation of stair data in small patient groups.  相似文献   

9.
The human hip joint is normally represented as a spherical hinge and its centre of rotation is used to construct femoral anatomical axes and to calculate hip joint moments. The estimate of the hip joint centre (HJC) position using a functional approach is affected by stereophotogrammetric errors and soft tissue artefacts. The aims of this study were (1) to assess the accuracy with which the HJC position can be located using stereophotogrammetry and (2) to investigate the effects of hip motion amplitude on this accuracy. Experiments were conducted on four adult cadavers. Cortical pins, each equipped with a marker cluster, were implanted in the pelvis and femur, and eight skin markers were attached to the thigh. Recordings were made while an operator rotated the hip joint exploiting the widest possible range of motion. For HJC determination, a proximal and a distal thigh skin marker cluster and two recent analytical methods, the quartic sphere fit (QFS) method and the symmetrical centre of rotation estimation (SCoRE) method, were used. Results showed that, when only stereophotogrammetric errors were taken into account, the analytical methods performed equally well. In presence of soft tissue artefacts, HJC errors highly varied among subjects, methods, and skin marker clusters (between 1.4 and 38.5 mm). As expected, larger errors were found in the subject with larger soft tissue artefacts. The QFS method and the distal cluster performed generally better and showed a mean HJC location accuracy better than 10 mm over all subjects. The analysis on the effect of hip movement amplitude revealed that a reduction of the amplitude does not improve the HJC location accuracy despite a decrease of the artefact amplitude.  相似文献   

10.
Kinematic data from 3D gait analysis together with musculoskeletal modeling techniques allow the derivation of muscle-tendon lengths during walking. However, kinematic data are subject to soft tissue artifacts (STA), referring to skin marker displacements during movement. STA are known to significantly affect the computation of joint kinematics, and would therefore also have an effect on muscle-tendon lengths which are derived from the segmental positions. The present study aimed to introduce an analytical approach to calculate the error propagation from STA to modeled muscle-tendon lengths. Skin marker coordinates were assigned uncorrelated, isotropic error functions with given standard deviations accounting for STA. Two different musculoskeletal models were specified; one with the joints moving freely in all directions, and one with the joints constrained to rotation but no translation. Using reference kinematic data from two healthy boys (mean age 9 y 5 m), the propagation of STA to muscle-tendon lengths was quantified for semimembranosus, gastrocnemius and soleus. The resulting average SD ranged from 6% to 50% of the normalized muscle-tendon lengths during gait depending on the muscle, the STA magnitudes and the musculoskeletal model. These results highlight the potential impact STA has on the biomechanical analysis of modeled muscle-tendon lengths during walking, and suggest the need for caution in the clinical interpretation of muscle-tendon lengths derived from joint kinematics.  相似文献   

11.
A new method using a double-sensor difference based algorithm for analyzing human segment rotational angles in two directions for segmental orientation analysis in the three-dimensional (3D) space was presented. A wearable sensor system based only on triaxial accelerometers was developed to obtain the pitch and yaw angles of thigh segment with an accelerometer approximating translational acceleration of the hip joint and two accelerometers measuring the actual accelerations on the thigh. To evaluate the method, the system was first tested on a 2° of freedom mechanical arm assembled out of rigid segments and encoders. Then, to estimate the human segmental orientation, the wearable sensor system was tested on the thighs of eight volunteer subjects, who walked in a straight forward line in the work space of an optical motion analysis system at three self-selected speeds: slow, normal and fast. In the experiment, the subject was assumed to walk in a straight forward way with very little trunk sway, skin artifacts and no significant internal/external rotation of the leg. The root mean square (RMS) errors of the thigh segment orientation measurement were between 2.4° and 4.9° during normal gait that had a 45° flexion/extension range of motion. Measurement error was observed to increase with increasing walking speed probably because of the result of increased trunk sway, axial rotation and skin artifacts. The results show that, without integration and switching between different sensors, using only one kind of sensor, the wearable sensor system is suitable for ambulatory analysis of normal gait orientation of thigh and shank in two directions of the segment-fixed local coordinate system in 3D space. It can then be applied to assess spatio-temporal gait parameters and monitoring the gait function of patients in clinical settings.  相似文献   

12.
When analysing human movement through stereophotogrammetry, skin-markers are used. Their movement relative to the underlying bone is known as a soft tissue artefact (STA). A mathematical model to estimate subject- and marker-specific STAs generated during a given motor task, is required for both skeletal kinematic estimators and comparative assessment using simulation. This study devises and assesses such a mathematical model using the paradigmatic case of thigh STAs. The model was based on two hypotheses: (1) that the artefact mostly depends on skin sliding, and thus on the angles of hip and knee; (2) that the relevant relationship is linear. These hypotheses were tested using data obtained from passive hip and knee movements in non-obese specimens and from running volunteers endowed with both skin- and pin-markers.  相似文献   

13.
This study used a single-subject design to establish a valid and reliable protocol for monitoring soft tissue motion under compression garments during drop landings. One male participant performed six 40 cm drop landings onto a force platform, in three compression conditions (none, medium high). Five reflective markers placed on the thigh under the compression garment and five over the garment were filmed using two cameras (1000 Hz). Following manual digitisation, marker coordinates were reconstructed and their resultant displacements and maximum change in separation distance between skin and garment markers were calculated. To determine reliability of marker application, 35 markers were attached to the thigh over the high compression garment and filmed. Markers were then removed and re-applied on three occasions; marker separation and distance to thigh centre of gravity were calculated. Results showed similar ground reaction forces during landing trials. Significant reductions in the maximum change in separation distance between markers from no compression to high compression landings were reported. Typical errors in marker movement under and over the garment were 0.1mm in medium and high compression landings. Re-application of markers showed mean typical errors of 1mm in marker separation and <3mm relative to thigh centre of gravity. This paper presents a novel protocol that demonstrates sufficient sensitivity to detect reductions in soft tissue motion during landings in high compression garments compared to no compression. Additionally, markers placed under or over the garment demonstrate low variance in movement, and the protocol reports good reliability in marker re-application.  相似文献   

14.
Functional calibration methods were devised to improve repeatability and accuracy of the knee flexion–extension axis, which is used to define the medio-lateral axis of the femur coordinate system in gait analysis. Repeatability of functional calibration methods has been studied extensively in healthy individuals, but not accuracy in the absence of a benchmark knee axis. We captured bi-plane fluoroscopy data of the knee joint in 17 subjects with unilateral total knee arthroplasty during treadmill walking. The prosthesis provided a benchmark knee axis to evaluate the functional calibration methods. Stereo-photogrammetry data of thigh and shank marker clusters were captured simultaneously to investigate the effect of soft tissue artefact (STA). Three methods were tested, the Axis Transformation Technique (ATT) finds the best single fixed axis of rotation, 2DofKnee finds the axis that minimises knee varus–valgus and trajAJC finds the axis perpendicular to the trajectory, in the transverse plane of the femur, of a point located on the longitudinal axis of the tibia. Using fluoroscopy data, functional axes formed an angle of less than 2° in the transverse plane with the benchmark axis. True internal–external range of movement was correlated with decreased accuracy for ATT, while varus–valgus range of movement was correlated with decreased accuracy for 2DofKnee and trajAJC. STA had negative impact on accuracy and variability. Using stereo-photogrammetry data, the accuracy of 2DofKnee was 1.7°(SD: 5.1°), smaller than ATT 2.9°(SD: 5.1°) but not to trajAJC 1.7°(SD: 5.2°). Our results confirm that of previous studies, which utilised the femur condylar axis as reference.  相似文献   

15.
16.
Many amputees who wear a leg prosthesis develop significant skin wounds on their residual limb. The exact cause of these wounds is unclear as little work has studied the interface between the prosthetic device and user. Our research objective was to develop a quantitative method for assessing displacement patterns of the gel liner during walking for patients with transtibial amputation. Using a reflective marker system and a custom clear socket, evaluations were conducted with a clear transparent test socket mounted over a plaster limb model and a deformable limb model. Distances between markers placed on the limb were measured with a digital caliper and then compared with data from the motion capture system. Additionally, the rigid plaster set-up was moved in the capture volume to simulate walking and evaluate if inter-marker distances changed in comparison to static data. Dynamic displacement trials were then collected to measure changes in inter-marker distance due to vertical elongation of the gel liner. Static and dynamic inter-marker distances within day and across days confirmed the ability to accurately capture displacements using this new approach. These results encourage this novel method to be applied to a sample of amputee patients during walking to assess displacements and the distribution of the liner deformation within the socket. The ability to capture changes in deformation of the gel liner will provide new data that will enable clinicians and researchers to improve design and fit of the prosthesis so the incidence of pressure ulcers can be reduced.  相似文献   

17.
The estimation of the skeletal motion obtained from marker-based motion capture systems is known to be affected by significant bias caused by skin movement artifacts, which affects joint center and rotation axis estimation. Among different techniques proposed in the literature, that based on rigid body model, still the most used by commercial motion capture systems, can smooth only part of the above effects without eliminating their main components. In order to sensibly improve the accuracy of the motion estimation, a novel technique, named local motion estimation (LME), is proposed. This rests on a recently described approach that, using virtual humans and extended Kalman filters, estimates the kinematical variables directly from 2D measurements without requiring the 3D marker reconstruction. In this paper, we show how such method can be extended to include the computation of the local marker displacement due to skin artifacts. The 3D marker coordinates, expressed in the corresponding local reference coordinate frames, are inserted into the state vector of the filter and their dynamics is automatically estimated, with adequate accuracy, without assuming any particular deformation function. Simulated experiments of lower limb motion, involving systematic mislocations (5, 10, 20 mm) and random errors of the marker coordinates and joint center locations (+/-5, +/-10, +/-15 mm), have shown that artifact motion can be substantially decoupled from the global skeletal motion with an effective increase of the accuracy wrt standard techniques. In particular, the comparison between the nominal kinematical variables and the one recovered from markers attached to the skin surface proved LME to be sensibly superior (50% in the worse condition) to the methods imposing marker-bone rigidity. In conclusion, while requiring further validation on real movement data, we argue that the proposed method can constitute an appropriate approach toward the improvement of the human motion estimation.  相似文献   

18.
Skin marker-based motion analysis has been widely used in biomechanical studies and clinical applications. Unfortunately, the accuracy of knee joint secondary motions is largely limited by the nonrigidity nature of human body segments. Numerous studies have investigated the characteristics of soft tissue movement. Utilizing these characteristics, we may improve the accuracy of knee joint motion measurement. An optimizer was developed by incorporating the soft tissue movement patterns at special bony landmarks into constraint functions. Bony landmark constraints were assigned to the skin markers at femur epicondyles, tibial plateau edges, and tibial tuberosity in a motion analysis algorithm by limiting their allowed position space relative to the underlying bone. The rotation matrix was represented by quaternion, and the constrained optimization problem was solved by Fletcher's version of the Levenberg-Marquardt optimization technique. The algorithm was validated by using motion data from both skin-based markers and bone-mounted markers attached to fresh cadavers. By comparing the results with the ground truth bone motion generated from the bone-mounted markers, the new algorithm had a significantly higher accuracy (root-mean-square (RMS) error: 0.7 ± 0.1 deg in axial rotation and 0.4 ± 0.1 deg in varus-valgus) in estimating the knee joint secondary rotations than algorithms without bony landmark constraints (RMS error: 1.7 ± 0.4 deg in axial rotation and 0.7 ± 0.1 deg in varus-valgus). Also, it predicts a more accurate medial-lateral translation (RMS error: 0.4 ± 0.1 mm) than the conventional techniques (RMS error: 1.2 ± 0.2 mm). The new algorithm, using bony landmark constrains, estimates more accurate secondary rotations and medial-lateral translation of the underlying bone.  相似文献   

19.
Skin-mounted marker based motion capture systems are widely used in measuring the movement of human joints. Kinematic measurements associated with skin-mounted markers are subject to soft tissue artifacts (STA), since the markers follow skin movement, thus generating errors when used to represent motions of underlying bone segments. We present a novel ultrasound tracking system that is capable of directly measuring tibial and femoral bone surfaces during dynamic motions, and subsequently measuring six-degree-of-freedom (6-DOF) tibiofemoral kinematics. The aim of this study is to quantitatively compare the accuracy of tibiofemoral kinematics estimated by the ultrasound tracking system and by a conventional skin-mounted marker based motion capture system in a cadaveric experimental scenario. Two typical tibiofemoral joint models (spherical and hinge models) were used to derive relevant kinematic outcomes. Intra-cortical bone pins equipped with optical markers were inserted in the tibial and femoral bones to serve as a reference to provide ground truth kinematics. The ultrasound tracking system resulted in lower kinematic errors than the skin-mounted markers (the ultrasound tracking system: maximum root-mean-square (RMS) error 3.44° for rotations and 4.88 mm for translations, skin-mounted markers with the spherical joint model: 6.32° and 6.26 mm, the hinge model: 6.38° and 6.52 mm). Our proposed ultrasound tracking system has the potential of measuring direct bone kinematics, thereby mitigating the influence and propagation of STA. Consequently, this technique could be considered as an alternative method for measuring 6-DOF tibiofemoral kinematics, which may be adopted in gait analysis and clinical practice.  相似文献   

20.
The purpose of this study was to quantify the effect of soft tissue artifact during three-dimensional motion capture and assess the effectiveness of an optimization method to reduce this effect. Four subjects were captured performing upper-arm internal-external rotation with retro-reflective marker sets attached to their upper extremities. A mechanical arm, with the same marker set attached, replicated the tasks human subjects performed. Artificial sinusoidal noise was then added to the recorded mechanical arm data to simulate soft tissue artifact. All data were processed by an optimization model. The result from both human and mechanical arm kinematic data demonstrates that soft tissue artifact can be reduced by an optimization model, although this error cannot be successfully eliminated. The soft tissue artifact from human subjects and the simulated soft tissue artifact from artificial sinusoidal noise were demonstrated to be considerably different. It was therefore concluded that the kinematic noise caused by skin movement artifact during upper-arm internal-external rotation does not follow a sinusoidal pattern and cannot be effectively eliminated by an optimization model.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号