首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high-performance liquid chromatographic method was developed for the simultaneous determination of phenylbutazone and its metabolites, oxyphenbutazone and γ-hydroxyphenylbutazone, in plasma and urine. Samples were acidified with hydrochloric acid and extracted with benzene—cyclohexane (1:1, v/v). The extract was redissolved in methanol and chromatographed on a μBondapak C15 column using a mobile phase of methanol—0.01 M sodium acetate buffer (pH 4.0) in a linear gradient (50 to 100% methanol at 5%/min; flow-rate 2.0 ml/min) in a high-performance liquid chromatograph equipped with an ultra-violet absorbance detector (254 nm). The detection limit for phenylbutazone, oxyphenbutazone and for γ-hydroxyphenylbutazone was 0.05 μg/ml.A precise and sensitive assay for the determination of phenylbutazone and its metabolites was established.  相似文献   

2.
A rapid, highly sensitive method for the determination of morphine and its metabolites morphine-3-glucuronide (M3G), morphine-6-glucuronide (M6G) and normorphine has been developed using high-performance liquid chromatography–electrospray mass spectrometry, with the deuterated analogues as internal standards. The analytes were extracted automatically using end-capped C2 solid-phase extraction cartridges. Baseline separation of morphine, M3G and M6G was achieved on a LiChrospher 100 RP-18 end-capped analytical column (125×3 mm I.D., 5 μm particle size) with water–acetonitrile–tetrahydrofuran–formic acid (100:1:1:0.1, v/v) as the mobile phase. Morphine and normorphine coeluate and were separated mass spectrometrically. The mass spectrometer was operated in the selected-ion monitoring mode using m/z 272 for normorphine, m/z 286 for morphine, m/z 462 for morphine-6-glucuronide. Due to an interfering peak, M3G was measured by tandem mass spectrometry in the daughter-ion mode. The limits of quantitation achieved with this method were 1.3 pmol/ml for morphine, 1.5 pmol/ml for normorphine, 1.0 pmol/ml for M6G and 5.4 pmol/ml for M3G in serum or cerebrospinal fluid. The limits of quantitation achieved in urine were 10 pmol/ml for morphine, 20 pmol/ml for normorphine and M6G and 50 pmol/ml for M3G using a sample size of 100 μl. The method described was successfully applied to the determination of morphine and its metabolites in human serum, cerebrospinal fluid and urine in pharmacokinetic and drug interaction studies.  相似文献   

3.
The simultaneous isolation and determination of mitoxantrone (Novantrone ®) and its two known metabolites (the mono- and dicarboxylic metabolites) were carried out using a high-performance liquid chromatographic (HPLC) system equipped with an automatic pre-column-switching system that permits drug analysis by direct injection of biological samples. Plasma or urine samples were injected directly on to an enrichment pre-column flushed with methanol-water (5:95, v/v) as the mobile phase. The maximum amount of endogenous water-soluble components was removed from biological samples within 9 min. Drugs specifically adsorbed on the pre-column were back-flushed on to an analytical column (Nucleosil C18, 250x4.6 mm I.D.) with 1.6 M ammonium formate buffer (pH 4.0) (2.5% formic acid) containing 20% acetonitrile. Detection was effected at 655 nm. Chromatographic analysis was performed within 12 min. The detection limit of the method was about 4 ng/ml for urine and 10 ng/ml for plasma samples. The precision ranged from 3 to 11% depending on the amount of compound studied. This technique was applied to the monitoring of mitoxantrone in plasma and to the quantification of the unchanged compound and its two metabolites in urine from patients receiving 14 mg/m2 of mitoxantrone by intravenous infusion for 10 min.  相似文献   

4.
A method is described for the simultaneous determination of l,α-acetylmethadol (LAAM) and five active metabolites — noracetylmethadol, dinoracetylmethadol, methadol, normethadol, and dinormethadol — in biofluids by high-performance liquid chromatography using a normal-phase column and a UV detector at 218 nm. The compounds are recovered from biofluids by a multistep liquid—liquid extraction. The mobile phase is methanol—acetonitrile (70:30, v/v) containing 0.015% ammonium hydroxide as the modifier. Retention times can be varied by adjusting the composition of the mobile phase to maximize peak height for quantitation using l-propranolol as the internal standard or peak separation for the collection of fractions. Using a UV detector the lower limit of sensitivity is 10 ng/ml of biofluid. Using fraction collection of radiolabeled drug and metabolites followed by liquid scintillation counting the lower limit of sensitivity is 1.0 ng/ml. Commonly used or abused narcotics including morphine, heroin, meperidine, methadone and propoxyphene do not interfere with the analysis. The method has been applied to plasma and urine samples from humans, sheep and rats. Extracts of urine from patients receiving maintenance treatment with LAAM contain LAAM and each of the five active metabolites.  相似文献   

5.
A new high-performance liquid chromatographic method for simultaneous determination of primidone (PRM) and of its three major metabolites, phenobarbital (PB), p-hydroxyphenobarbital (p-HO-PB) and phenylethylmalonamide (PEMA), in rat urine, was developed. After acid hydrolysis, these compounds were extracted from urine by means of a Bond Elut Certify LRC column with good clean-up. The extracts were chromatographed on a C18 reversed-phase column using isocratic elution at 40°C, with UV detection at 227 nm. The limit of detection was 0.5 mg/ml for the four compounds. Good linearity (r2>0.99) was observed within the calibration ranges studied: 37.4–299.3 μg/ml for PRM, 26.4–211.2 μg/ml for PB, 12.5–100.2 μg/ml for p-HO-PB and 12.1–97.0 μg/ml for PEMA. Repeatability was in the range 3.1–6.8%. This method constitutes a useful tool for studies on the influence of various parameters on primidone metabolism.  相似文献   

6.
A method for the simultaneous direct determination of salicylate (SA), its labile, reactive metabolite, salicyl acyl glucuronide (SAG), and two other major metabolites, salicyluric acid and gentisic acid in plasma and urine is described. Isocratic reversed-phase high performance liquid chromatography (HPLC) employed a 15-cm C18 column using methanol-acetonitrile-25 mM acetic acid as the mobile phase, resulting in HPLC analysis time of less than 20 min. Ultraviolet detection at 310 nm permitted analysis of SAG in plasma, but did not provide sensitivity for measurement of salicyl phenol glucuronide. Plasma or urine samples are stabilized immediately upon collection by adjustment of pH to 3–4 to prevent degradation of the labile acyl glucuronide metabolite. Plasma is then deproteinated with acetonitrile, dried and reconstituted for injection, whereas urine samples are simply diluted prior to injection on HPLC. m-Hydroxybenzoic acid served as the internal standard. Recoveries from plasma were greater than 85% for all four compounds over a range of 0.2–20 μg/ml and linearity was observed from 0.1–200 μg/ml and 5–2000 μg/ml for SA in plasma and urine, respectively. The method was validated to 0.2 μg/ml, thus allowing accurate measurement of SA, and three major metabolites in plasma and urine of subjects and small animals administered salicylates. The method is unique by allowing quantitation of reactive SAG in plasma at levels well below 1% that of the parent compound, SA, as is observed in patients administered salicylates.  相似文献   

7.
A rapid, sensitive method using liquid chromatography–electrospray mass spectrometry (LC–ES-MS) was developed and evaluated for the simultaneous quantitative determination of caffeine metabolites 1U, 1X and AAMU in human urine. This method involved a simple dilution of urine samples. The chromatographic separation was achieved on a C18 reversed-phase column using a gradient of acetonitrile in 2 mM, pH 3.0 ammonium formate as mobile phase. After ionisation in an electrospray source, mass spectrometric detection was performed in the negative ion, selected ion monitoring mode. This method yielded acceptable accuracy and precision within the range 0.25–50 μg/ml. This analytical method was applied to investigate the N-acetylator phenotype of HIV-infected patients and compared with high-performance liquid chromatography with UV detection. Its specificity was better, which appeared to be absolutely necessary to prevent errors in metabolic ratios and phenotype interpretation.  相似文献   

8.
A high-performance liquid chromatographic method for the determination of a new fluoroquinolone antimicrobial agent, (S)-10-[(S)-(8-amino-6-azaspiro[3,4]octan-6-yl)]-9-fluoro-2,3-dihydro-3-methyl-7-oxo-7H-pyrido [1,2,3-de][1,4]benzoxazine-6-carboxylic acid hemihydrate (DV-7751a, I) in human serum and urine has been developed. Compound I and the internal standard were extracted from serum and urine by means of Bond Elut C8 LRC column. The extracts were chromatographed on a reversed-phase Inertsil ODS-2 column using tetrahydrofuran-50 mM KH2PO4 (pH 2)-1 M ammonium acetate (19:81:1, v/v) as the mobile phase at a flow-rate of 1.0 ml/min. Fluorescence detection at an excitation wavelength of 305 nm and an emission wavelength of 530 nm resulted in a limit of quantitation of 0.0098 μg/ml for serum and 0.098 μg/ml for urine. The method showed satisfactory sensitivity, precision, accuracy, recovery and selectivity. Stability studies showed that I was stable in serum and urine for at least 1 month at −20°C and for at least 48 h at room temperature.  相似文献   

9.
A simple high-performance liquid chromatographic method was developed for the determination of vanillin and its vanillic acid metabolite in human plasma, red blood cells and urine. The mobile phase consisted of aqueous acetic acid (1%, v/v)–acetonitrile (85:15, v/v), pH 2.9 and was used with an octadecylsilane analytical column and ultraviolet absorbance detection. The plasma method demonstrated linearity from 2 to 100 μg/ml and the urine method was linear from 2 to 40 μg/ml. The method had a detection limit of 1 μg/ml for vanillin and vanillic acid using 5 μl of prepared plasma, red blood cells or urine. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of vanillin in patients undergoing treatment for sickle cell anemia.  相似文献   

10.
A high-performance liquid chromatographic method for the measurement of bumetamide in plasma and urine is described. Following precipitation of proteins with acetonitrile, bumetanide was extracted from plasma or urine on a 1-ml bonded-phase C18 column and eluted with acetonitrile. Piretanide dissolved in methanol was used as the internal standard. A C18 Radial Pak column and fluorescence detection (excitation wavelength 228 nm; emission wavelength 418 nm) were used. The mobile phase consisted of methanol—water—glacial acetic acid (66:34:1, v/v) delivered isocratically at a flow-rate of 1.2 ml/min. The lower limit of detection for this method was 5 ng/ml using 0.2 ml of plasma or urine. Nafcillin, but not other semi-synthetic penicillins, was the only commonly used drug that interfered with this assay. No interference from endogenous compounds was detected. For plasma, the inter-assay coefficients of variation of the method were 7.6 and 4.4% for samples containing 10 and 250 ng/ml bumetanide, respectively. The inter-assay coefficients of variation for urine samples containing 10 and 2000 ng/ml were 8.1 and 5.7%, respectively. The calibration curve was linear over the range 5–2000 ng/ml.  相似文献   

11.
A high-performance liquid chromatographic method for quantitation of ibuprofen from serum and application of this method to ibuprofen disposition in the dog is described. The drug was extracted from acidified plasma with dichloromethane. The internal standard used was a methanolic solution of 4-n-butylphenylacetic acid. A μBondapak C1 column was used for analysis; the mobile phase was methanol—water—glacial acetic acid (pH 3.4) (75:24:1, v/v). A wavelength of 272 nm was used to monitor ibuprofen and the internal standard.Method sensitivity was 0.5 μg/ml serum using either 0.5 or 1.0 ml of sample, and no interference was found from endogenous compounds or other commonly used anti-inflammatory agents. The coefficients of variation of the method were 4.2% and 6.0% for samples containing 50.0 and 6.25 μg/ml of ibuprofen, respectively, and the calibration curve was linear for the range of 0.5 to 100 μg/ml. This method was demonstrated to be suitable for pharmacokinetic and/or biopharmaceutical studies of ibuprofen in man and the dog.  相似文献   

12.
A simple, accurate and precise high-performance liquid chromatographic method was developed and validated for the determination of trovafloxacin, a new quinolone antibiotic, in serum and urine. Following solid-phase extraction, chromatographic separation was accomplished using a C18 column with a mobile phase consisting of 0.04 M H3PO4-acetonitrile-tetrabutylammonium hydroxide-0.005 M dibutyl amine phosphate (D-4) reagent (83:16.85:0.05:0.1, v/v), pH 3. Trovafloxacin and the internal standard (a methyl derivative of trovafloxacin) were detected by ultraviolet absorbance at 275 nm. The lower limit of quantification for trovafloxacin was 0.1 μg/ml and the calibration curves were linear over a concentration range of 0.1 to 20..0 μg/ml (r2 = 0.9997). The average recoveries were greater than 70% for both trovafloxacin and internal standard. The intra-day and inter-day coefficients of variation were generally less than 5% in urine and serum over the concentration range of 0.1 to 20.0 μg/ml. Human serum samples could be stored for up to 12 months at −20°C and urine samples could be stored up to 18 months at −80°C.  相似文献   

13.
Ebastine (CAS 90729-43-4) is an antiallergic agent which selectively and potently blocks histamine H1-receptors in vivo. A simple and sensitive high-performance liquid chromatography (HPLC) method is described for the simultaneous determination of ebastine and its two oxidized metabolites, carebastine (CAS 90729-42-3) and hydroxyebastine (M–OH), in human plasma. After a pretreatment of plasma sample by solid-phase extraction, ebastine and its metabolites were analyzed on an HPLC system with ultraviolet detection at 254 nm. Chromatography was performed on a cyano column (250×4.0 mm I.D.) at 40 °C with the mobile phase of acetonitrile–methanol–0.012 M ammonium acetate buffer (20:30:48, v/v/v) at a flow rate of 1.2 ml/min. Accurate determinations were possible over the concentration range of 3–1000 ng/ml for the three compounds using 1 ml plasma samples. The intra- and inter-day assay accuracy of this method were within 100±15% of nominal values and the precision did not exceed 12.4% of relative standard deviation. The lower limits of quantitation were 3 ng/ml for ebastine and its metabolites in human plasma. This method was satisfactorily applied to the determination of ebastine and its two oxidized metabolites in human plasma after oral administration of ebastine.  相似文献   

14.
An improved, more efficient method for the determination of metoprolol and its two metabolites in human urine is reported. The simultaneous analysis of the zwitterionic metoprolol acidic metabolite (III, H117/04) with the basic metabolites α-hydroxymetoprolol (II, H119/66), metoprolol (I) and guanoxan (IV, internal standard) was achieved employing solid-phase extraction and isocratic reversed-phase HPLC. The analytes were extracted from urine (100 μl) using C18 solid-phase extraction cartridges (100 mg), and eluted with aqueous acetic acid (0.1%, v/v)–methanol mixture (40:60, v/v, 1.2 ml). The eluents were concentrated (250 μl) under vacuum, and aliquots (100 μl) were analysed by HPLC with fluorescence detection at 229 nm (excitation) and 309 nm (emission) using simple isocratic reversed-phase HPLC (Novapak C18 radial compression cartridge, 4 μm, 100×5 mm I.D.). Acetonitrile–methanol–TEA/phosphate buffer pH 3.0 (9:1:90, v/v) was employed as the eluent (1.4 ml/min). All components were fully resolved within 18 min, and the calibration curves for the individual analytes were linear (r2≥0.996) within the concentration range of 0.25–40.0 mg/ml. Recoveries for all four analytes were greater than 76% (n=4). The assay method was validated with intra-day and inter-day variations less than 2.5%.  相似文献   

15.
A fully automated gradient high-performance liquid chromatographic method for the determination of isotretinoin, tretinoin and their 4-oxo metabolites in plasma was developed, using the column-switching technique. After dilution with an internal standard solution containing 20% acetonitrile, 0.5 ml of the sample was injected onto a precolumn (17x4.6 mm I.D.), filled with C18 Corasil 37–53 μm. Proteins and polar plasma components were washed out using 1% ammonium acetate-acetonitrile (9:1, v/v) as mobile phase 1. After valve switching, the retained components were transferred to the analytical column in the backflush mode, separated by gradient elution and detected at 360 nm by UV detection. Using two coupled reversed-phase columns (125 mm long), the separation of cis and trans isomers was possible, and all four compounds could be quantified down to 2 ng/ml of plasma. The inter-assay precision in the concentration range 20-1000 ng/ml was between 1.0 and 4.7% for all compounds.  相似文献   

16.
A simple approach to the quantitation of ciprofloxacin and its three metabolites, M1 (desethylene-ciprofloxacin), M2 (sulfo-ciprofloxacin) and M3 (oxo-ciprofloxacin), in human serum, urine, saliva and sputum is described. This assay allows the parent drug and its metabolites to elute and be resolved in a single chromatogram at 280 nm using a linear gradient. The procedure involved liquid—liquid extraction. Separation was achieved on a C18 reversed-phase column. The limit of detection of ciprofloxacin is 0.05 μg/ml and that of its three metabolites is 0.25 μg/ml. This method is sufficiently sensitive for pharmacokinetic studies.  相似文献   

17.
A rapid high-performance liquid chromatographic method has been developed to determine piromidic acid in trout muscle tissue and in urine, in the presence of nalidixic, 7-hydroxymethylnalidixic, oxolinic and pipemidic acids and cinoxacin. A Nova-Pak C18 column was used with acetonitrile–4·10−4 M oxalic acid (40:60, v/v) as the mobile phase. A post-column change of pH was made with NaOH. Fluorimetric detection at 456 nm (λex 275 nm) was used. The instrumental detection limit was 5.91 ng/ml, based on height of peak. Pretreatment of the urine samples was not necessary and fish samples were extracted with sodium hydroxide solutions and cleaned by means of an extraction with chloroform. Detection limit was 147 ng/ml for urine and 5.91 ng/g for trout muscle. Good separation without interference from any other components was obtained. Recovery was better than 87% in urine and better than 72% in trout muscle tissue.  相似文献   

18.
An isocratic high-performance liquid chromatographic (HPLC) method with ultraviolet detection is described for the quantification of the atypical neuroleptic clozapine and its major metabolites, N-desmethylclozapine and clozapine N-oxide, in human serum or plasma. The method included automated solid-phase extraction on C18 reversed-phase material. Clozapine and its metabolites were separated by HPLC on a C18 ODS Hypersil analytical column (5 μm particle size; 250 mm × 4.6 mm I.D.) using an acetonitrile—water (40:60, v/v) eluent buffered with 0.4% (v/v) N,N,N′,N′-tetramethylethylenediamine and acetic acid to pH 6.5. Imipramine served as internal standard. After extraction of 1 ml of serum or plasma, as little as 5 ng/ml of clozapine and 10 or 20 ng/ml of the metabolites were detectable. Linearity was found for drug concentrations between 5 and 2000 ng/ml as indicated by correlation coefficients of 0.998 to 0.985. The intra- and inter-assay coefficients of variation ranged between 1 and 20%. Interferences with other psychotropic drugs such as benzodiazepines, antidepressants or neuroleptics were negligible. In all samples, collected from schizophrenic patients who had been treated with daily oral doses of 75–400 mg of clozapine, the drug and its major metabolite, N-desmethylclozapine, could be detected, while the concentrations of clozapine N-oxide were below 20 ng/ml in three of sixteen patients. Using the method described here, data regarding relations between therapeutic or toxic effects and drug blood levels or metabolism may be collected in clinical practice to improve the therapeutic efficacy of clozapine drug treatment.  相似文献   

19.
A reliable reversed-phase high-performance liquid chromatographic method was developed for the determination of liposomal nystatin in plasma. Nystatin is extracted by 1:2 (v/v) liquid–liquid extraction with methanol. Separation is achieved by HPLC after direct injection on a μBondapak™ C18 analytical column with a mobile phase composed of 10 mM sodium phosphate, 1 mM EDTA, 30% methanol and 30% acetonitrile adjusted to pH 6. Detection is by ultraviolet absorbance at 305 nm. Quantitation is based on the sum of the peak area concentration of the two major isomers of nystatin, which elute at 7.5–8.5 and 9.5–10.5 min. The assay was linear over the concentration range of 0.05 to 50 μg/ml. The lower limit of quantitation was 0.05 μg/ml, sufficient for investigating the plasma pharmacokinetics of liposomal nystatin in preclinical studies. Accuracies and intra- and inter-day precision showed good reproducibility. With minor modifications, this method also was used for assaying nystatin in various non-plasma body fluids and tissues.  相似文献   

20.
A HPLC–UV determination of clobazam and N-desmethylclobazam in human serum and urine is presented. After simple liquid–liquid extraction with dichloromethane the compounds and an internal standard diazepam were separated on a Supelcosil LC-8-DB column at ambient temperature under isocratic conditions using the mobile phase: CH3CN–water–0.5 M KH2PO4–H3PO4 (440:540:20:0.4, v/v and 360:580:60:0.4, v/v for serum and urine, respectively). The detection was performed at 228 nm with limits of quantification of 2 ng/ml for serum and 1 ng/ml for urine. Relative standard deviations for intra- and inter-assay precision were found below 8% for both compounds for all the tested concentrations. The described procedure may be easily adapted for several 1,4-benzodiazepines.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号