1.
This paper describes the development of a simple and sensitive analytical method for the quantification of melatonin in human plasma and rabbit serum, using standard analytical equipment and on-line column enrichment without prior extraction, clean-up or derivatization. The analytical procedure was found to be accurate, precise and linear. For human plasma, the accuracy was 101% (range 89–106%), and the mean precision was 5% (range 2–9%) for all concentrations (0, 2, 10, 50 and 200 ng/ml) tested (n=6). The accuracy in rabbit serum was 101% (range 90–112%), and the mean precision was 13% (range 8–19%) for all concentrations (0, 2, 10, 50, 200 and 500 ng/ml) tested (n=6). The retention time of melatonin was about 8 min and the total recoveries were found to be approximately 65 and 85%, respectively, for human plasma and rabbit serum. The limit of detection was found to be lower than 1 ng/ml for human plasma and around 2 ng/ml for rabbit serum. The method is, therefore, found to be suitable for melatonin bioavailability studies in rabbits and presumably also in humans.  相似文献   

2.
3.
4.
A validated high-performance liquid chromatographic procedure employing ultraviolet detection for the analysis of diclofenac in human plasma is reported. The method is rapid and, coupled with column switching, leads to a sensitive, accurate and reproducible assay. The retention times of diclofenac and the internal standard (4′-methoxydiclofenac, CGP-4287) are 6.4 and 7.6 min, respectively. The peak height versus plasma concentration is linear over the range 5.0–2000 ng/ml with a detection limit below 2.5 ng/ml. The mean absolute recovery of diclofenac using the described assay is 96.5% (n = 24). The inter- and intra-day accuracy and precision are within 8.3% of the actual values for all concentrations investigated. Furthermore, this procedure is applied to assess the pharmacokinetics of a single 75-mg oral dose of diclofenac sodium.  相似文献   

5.
A fully automated column-switching high-performance liquid chromatographic (HPLC) method was developed for the quantification of finasteride [N-(1,1-dimethylethyl)-3-oxo-4-aza-5α-androst-1-ene-17β-carboxamide] in human plasma. Plasma samples were diluted with an equal volume of ethylene glycol-water (40:60, v/v), then the diluted sample (150 μl) was injected into the HPLC system without clean-up. The analyte was retained on a pretreatment column, whereas plasma proteins and other endogenous components were washed out to waste. The analyte was transferred to the analytical column in the heart-cut mode and then detected at 210 nm. A quantification limit of 1 ng/ml was attained. There was a linear relationship between peak height and drug concentration in plasma in the range 1–50 ng/ml. This method was validated and applied to the assay of plasma samples to characterize pharmacokinetic parameters in clinical studies.  相似文献   

6.
7.
8.
A high-performance liquid chromatographic method has been developed for the determination of nitroxoline in 50-μl plasma and urine samples.A structural analogue of nitroxoline, 8-hydroxyquinoline, was added to the eluent in order to suppress peak asymmetry. Several parameters of the eluent were studied for the optimisation of the chromatographic system.Plasma concentration—time curves were constructed for three volunteers after they had received an oral dose of 100 mg of nitroxoline. Plasma half-life was about 1 h. Within 12 h, about 1% of the dose was excreted in the urine as free nitroxoline and about 30% as conjugated metabolite of the parent compound.  相似文献   

9.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a μBondapak C18 column preceded by a 4–5 cm × 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 μg/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 μg/ml isoxicam were 1.86 ± 0.077, 4.10 ± 0.107 and 8.43 ± 0.154 μg/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 μg/ml. The precision of the method was 3.3–9.0% relative standard deviation over the linear range.  相似文献   

10.
The objective of the study was to develop a sensitive and specific assay for studying the pharmacokinetics of a novel calcium antagonist, a benzimidazolyl-substituted tetraline derivative, mibefradil (I) in the dog. The assay involves liquid-liquid extraction of a biological sample, reversed-phase HPLC separation and fluorescence detection (λex = 270 nm and λem = 300 nm) of a sample components. Each sample was eluted with a mobile phase pumping at a flow-rate of 2 ml/min. The mobile phase composition was a mixture of acetonitrile and aqueous solution (38:62, v/v). The aqueous solution contains 0.0393 M KH2PO4 and 0.0082 M Na-pentanesulphonic acid. The retention times were 10.7 min for I, and 12.2 min for internal standard Ro 40–6792. Calibration curves with concentrations of I ranging from 10 to 500 ng/ml were linear (r2 > 0.99). The detection limit for I was 0.5 ng/ml when 0.5 ml of plasma or urine was used. Intra- and inter-day accuracy and precision were within 10%. The assay was successfully applied to the pharmacokinetic studies of I in dogs.  相似文献   

11.
A high-performance liquid chromatographic method is described for measuring submicrogram quantities of dianhydrogalactitol, a promising anti-neoplastic agent, in plasma. The drug is derivatized directly in plasma with sodium diethyldithiocarbamate to form a bis(dithiocarbamoyl) ester which absorbs UV light at 254 nm (αm 17,000). The derivatized product is then extracted quantitatively into chloroform and separated by normal phase chromatography (μBondpak CN column). Dianhydrogalactitol concentration below 50 ng/ml of plasma can be detected in the eluent.  相似文献   

12.
A rapid, sensitive, and specific high-performance liquid chromatographic method is described for the quantitative analysis of dipyridamole in plasma and whole blood. The method involves a single extraction of an alkalinized sample with diethyl ether followed by evaporation of the organic solvent and ion-pair chromatography using fluorescence detection. The lower limit of sensitivity for dipyridamole is 1 ng/ml. Concentrations of dipyridamole between 1 and 500 ng per sample are measured with an average coefficient of variation of 4.5% in plasma and 7.4% in whole blood.  相似文献   

13.
14.
15.
A reliable reversed-phase high-performance liquid chromatographic method has been developed for the determination of bromocriptine (BCT) in plasma and eye tissues. The BCT and propranolol, added as an internal standard (I.S.), were extracted by a liquid–liquid technique followed by an aqueous back-extraction, allowing injection of an aqueous solvent into a 4-μm Nova-Pak C18 column (150×3.9 mm I.D.). The mobile phase was a mixture of 30 parts of acetonitrile and 70 parts of 0.2% triethylamine (pH 3) at a flow-rate of 1 ml/min. Fluorescence detection was at an excitation wavelength of 330 nm and an emission wavelength of 405 nm. The retention times of I.S. and BCT were 4.1 and 11.6 min, respectively. The calibration curve was linear over the concentration range 0.2–10 μg/l for plasma (r>0.999) and vitreous humour (r>0.997) and 1–50 μg/l for aqueous humour (r>0.985). The limit of quantification was 0.2 μg/l for plasma and vitreous humour using a 1-ml sample and was 1 μg/l for aqueous humour using a 0.2-ml sample. The quality control samples were reproducible with acceptable accuracy and precision. The within-day recovery (n=3) was 100–102% for plasma, 91–106% for aqueous humour and 96–111% for vitreous humour. The between-day recovery (n=9) was 90–114% for plasma, 83–115% for aqueous humour and 90–105% for vitreous humour. The within-day precision (n=3) and the between-day precision (n=9) were 1.7–7.0% and 8.1–13.6%, respectively. No interferences from endogenous substances were observed. Taken together, the above simple, sensitive and reproducible high-performance liquid chromatography assay method was suitable for the determination of BCT in plasma and eye tissues following ocular application of BCT for the therapy of myopia.  相似文献   

16.
A high-performance liquid chromatographic method with ultraviolet absorbance detection at 260 nm was developed for the analysis of fluconazole in plasma. The method involves sample clean-up by liquid-liquid extraction. The proposed technique is reproducible, selective, reliable and sensitive. Calibration standards were prepared in the range 1.25-20 mg/l. The limit of quantitation was 0.4 mg/l. The coefficients of variation were 5% between measurements of a single extract injected in duplicate, and 7% between two extractions of spiked samples at the same concentrations. The separation between fluconazole and endogenous substances was satisfactory. This method was designed in order to minimise the risk of interference from substances that could be co-administered to critically ill patients undergoing hemodiafiltration. With a run time below 5 min, the present method is rapid and easy to use for later clinical studies, as well as for routine monitoring.  相似文献   

17.
A cation-sensing electrode can be used to monitor enzymatic reactions if their substrates and products differ in the ability to bind the cation. In the first method, the electrode potential vs time curve is recorded. The second, metal-stat method consists of measuring the rate at which substrate must be added to the reaction medium in order to keep the electrode potential at a constant level. These approaches have been used to assay inorganic pyrophosphatase, carboxypeptidase A, and hexokinase with the Mg2+ and Cu2+ ions as the indicators.  相似文献   

18.
A rapid, selective and sensitive isocratic reversed-phase high-performance liquid chromatographic method for the determination of ganciclovir in plasma samples was developed. This method, which was applied to the analysis of plasma ganciclovir from heart transplant patients under ganciclovir therapy for cytomegalovirus infections, represents a suitable analytical tool for drug monitoring and pharmacokinetic investigations.  相似文献   

19.
This report describes the analysis of pentamidine by isocratic reversed-phase high-performance liquid chromatography (HPLC) using a commercially available compound (melphalan) as the external standard. Previously described assays use ion-pairing HPLC, an internal standard (hexamidine) that is not readily available, and require a relatively large sample size. In the present assay, pentamidine was extracted from plasma using solid-phase extraction and was analyzed using a C18 column and a mobile phase containing 18% acetonitrile, 2% methanol, 0.2 M ammonium acetate and 0.5% triethylamine. The identity of the eluting peaks was verified using a diode array detector. The extraction yield of pentamidine was 82%. The limit of detection was 8.6 ng/ml with a sample size of 100 μl. The inter-day and intra-day coefficients of variation ranged between 0.3% and 10% with an average of 5%. This method was applied to study the pharmacokinetics of pentamidine in rodents.  相似文献   

20.
A sensitive and selective chiral high performance liquid chromatographic method was developed for the direct determination of R- and S-warfarin enantiomers in human plasma. The method involved direct injection of human plasma onto a semipermeable surface (SPS) guard column, washing the proteins from the column with aqueous acetonitrile and back flushing the analytes onto a reversed phase ovomucoid silica HPLC column using switching valves. After separation, the analytes were simultaneously detected and quantitated with a fluorometer. The recoveries of R-warfarin from human plasma at 25 and 2500 ng/ml were 98.9% and 88.1%, respectively. The recoveries of S-warfarin at 25 and 2500 ng/ml were 105.4% and 93.9%, respectively. Using 100 microl of human plasma, the lower limit of quantification for both R- and S-warfarins was 25 ng/ml. Linear responses in analyte/internal standard peak height ratios were observed for analyte concentrations ranging from 25 to 2500 ng/ml for both enantiomers. Fluorescence chromatograms of drug-free human plasma showed no interfering peaks with retention times similar to those for R- and S-warfarins and the internal standard. Results from a 3-day validation study for both enantiomers demonstrated excellent precision (1.7-9.0%) and accuracy (97-109%) across the calibration range.  相似文献   