1.
The quantitative determination of pipecolic acid was examined.

The reaction of 3% ninhydrin solution in n-butanol, saturated with citrate buffer (pH 4.2), with pipecolic acid in boiling water for 3 min yielded the colored products showing λmax at 570 mμ, but with proline hardly yielded those products. By the colorimetry proposed, it is possible to determine the amount of pipecolic acid in the sample containing proline no more than 50 times the amount of the pipecolic acid, directly from the calibration curve using pipecolic acid.

The method for removal of amino acids from the sample containing pipecolic acid and proline was examined and discussed.  相似文献   

2.
Summary. In the present study we describe a simple and fast method to measure the concentration of total free amino acids in very small amounts of biological tissues. The procedure described here is based on the reaction of free amino acids with o-phthaldialdehyde (OPA) in the presence of a reducing agent, β-mercaptoethanol (MET), to give a complex which can be measured by fluorescence. It is a very rapid process and has the same reliability as the conventional ninhydrin method of Moore and Stein but is about 500 times more sensitive. The sensitivity of the new protocol is such to permit the determination with high reliability of very small amounts of free amino acids at picomole levels, either in a standard amino acid mixture or in biological tissues, without chromatographic separation of the amino acids. It is particularly useful when the amount of the sample is very low, e.g. on a single pituitary or pineal gland of small animals or on single cells, such as oocytes or eggs, as well as single ganglions or axons of marine invertebrates. Received September 22, 1999 Accepted July 5, 2000  相似文献   

3.
The amino acids in methanol-soluble extracts of Xenopus oocytes were measured using a method involving precolumn derivatization with phenylisothiocyanate and reverse phase HPLC of the derivatized amino acids. This technique allows the estimation of asparagine and glutamine pools in oocytes, estimated as 70 and 283 pmoles per oocyte, respectively. The pool sizes of the other amino acids were similar to previously reported results obtained using conventional ion exchange chromatography and postcolumn derivatization with ninhydrin. The advantages of the method developed here include picomolar sensitivity and the enhanced resolution of asparagine and glutamine from other amino acids. The kinetics of aspartic acid and asparagine utilization were monitored following microinjection of oocytes with [3H]aspartic acid and [14C]asparagine. The aspartic acid pool turned over rapidly with a half-time of <30 min. The asparagine pool was metabolized much more slowly and appeared to be utilized almost completely for protein synthesis. The absolute rate of protein synthesis in oocytes was calculated from the incorporation data and chemical pool measurements as ~25 ng/hr-oocyte. The methodology developed here may be useful in experimental situations involving limited amounts of biological material. © 1994 Wiley-Liss, Inc.  相似文献   

4.
The use of appropriate fluorometric derivatization procedures is of considerable importance for accurate determination of amino acids in biological samples and in metal-assisted peptide hydrolysis reactions. It is especially critical for the relative fluorescence intensities (RFI) of equal amounts of amino acids to be as similar as possible. While fluorescamine and naphthalene-2,3-dicarboxaldehyde (NDA) have proven to be excellent fluorogenic reagents for amino acid detection, the effects of various factors such as organic solvent, buffer, and pH have never been rigorously evaluated with respect to normalizing the relative fluorescence intensities of individual amino acids. To this end, here we describe optimized fluorescamine and NDA derivatization reactions that enhance the accuracy of microplate-based detection of amino acids. For both fluorescamine and NDA, we have shown that the RFI values of 16 of 19 amino acids are greater than 70%. Although determination of tryptophan is problematic, this difficulty is overcome by the addition of beta-cyclodextrin to the NDA reaction. In principle, the optimized fluorescamine and NDA microplate procedures reported here can be utilized as complementary techniques for the detection of 19 of 20 naturally occurring amino acids.  相似文献   

5.
A simple and rapid method for sialic acid determination in sialoglycoproteins by acidic ninhydrin reaction is described. The method is based on the reaction of sialic acids with an acidic ninhydrin reagent (K. Yao and T. Ubuka (1987) Acta Med. Okayama 41, 237-241). By heating a sample solution containing sialoglycoprotein with the reagent at 100 degrees C for 10 min, a stable color with an absorption maximum at 470 nm was produced. The standard curve was linear in the range of 20 micrograms to 3 mg of fetuin, a sialoglycoprotein, per 3.0 ml of the reaction mixture. The reaction is specific only for sialoglycoproteins among various proteins examined. The acidic ninhydrin method was applied to the determination of sialic acids in sialoglycoproteins in ascites fluids of Ehrlich ascites tumor-bearing mice.  相似文献   

6.
Peroxidation of lipids produces low-molecular-weight carbonyl compounds, which are reactive with biological nucleophiles. The analysis of these compounds is often difficult. A multicomponent method for the determination of 11 of them in biological samples is reported. The samples are subjected to a pretreatment-derivatization procedure followed by gas chromatographic analysis with either electron-capture detection (ECD) or mass-selective detection (MSD) in the selected-ion monitoring mode. The procedure involves derivatization of the analyte with 2,4,6-trichlorophenylhydrazine, extraction with n-hexane, and separation of the derivatization products on a nonpolar gas chromatographic column. The concentration of the derivatization reagent, pH, reaction time, temperature, and presence of extraneous ions were investigated to determine the optimal derivatization conditions. Under these conditions, the method allows for the selective detection of low-molecular-weight carbonyl compounds at femtomole levels in several biological materials such as plasma, urine, and bovine serum albumin without interferences. The limits of detection were in the ranges 0.01-0.2 microM for ECD and 0.15-1.5 microM for MSD. The mean procedural recoveries obtained during the method validation were within the range 85-95% and the intra- and interassay standard deviations do not exceed 4.6 and 6.1%, respectively.  相似文献   

7.
A fluorimetric method for the determination of tryptophan in animal tissues   总被引:1,自引:1,他引:0  
Tryptophan, tryptamine and peptides containing N-terminal tryptophan give two highly fluorescent products on treatment with dithiothreitol and acid ninhydrin reagent 1 or 2. The first fluorescent product (product A) gives an emission at 500nm on activation at 390–400nm and is stable for 20min. The second product (product B), which gives an emission at 530nm on activation at 470nm, is detectable within 1h after the reaction. It gives almost maximum intensity in 4h and is stable for at least 48h. Except lysine, which in equimolar amounts gives less than 1% of a product similar to product B, no other naturally occurring amino compounds give fluorescent products. A procedure is given for the determination of 0.05–34nmol of tryptophan in tissue extracts. By using this procedure rat brain was found to contain 17.56±0.76 (s.e.m.) nmol/g wet wt.  相似文献   

8.
Argininosuccinate has been determined in normal serum and liver extract of rats by chromatographic analysis on Dowex-1-acetate after a brief period of in vivo labeling with l-[U-14C] citrulline. The amounts found were within the range of other amino acid intermediates of the ornithine cycle, determined in the same samples. Both 14C and ninhydrin color were measured. Chromatography on Amberlite columns, subsequent to fractionation on Dowex, allowed determination of the other amino acids. Fractionation on Dowex-1-acetate provides a reliable and highly selective method for the analysis of minute amounts of argininosuccinate in biological samples containing other amino acids.  相似文献   

9.
A liquid chromatography procedure is described for the determination of some estrogens using fluorescence detection. The estrogens are labeled by precolumn derivatization with 5-dimethylaminonaphthalene-1-sulfonylchloride (dansyl chloride) and chromatographed on a reversed-phase, C-18 column with a mobile phase consisting of methanol, water, and acetic acid. The eluted analytes are measured with a fluorescence detector using excitation and emission wavelengths of 350 and 540 nm, respectively. The chief advantage of this new procedure is its sensitivity, requiring smaller amounts of sample to detect and quantitate estrogens in biological materials. We could detect less than 400 pg of estriol. With our procedure, this corresponded to about 25 ng in the final reaction mixture, before derivatization. The use of smaller sample volumes could improve this limit. Linearity for dansylated estriol, estrone, and estradiol was excellent over the estrogen range below 100 μg in the sample. This corresponds to approximately 1.7 μg on the column. Within-run precision was better than 5% for the full extraction and derivatization procedure for estriol from pregnancy urine samples. Chromatography is complete within 10 min for dansylated estriol, estrone, and estradiol.  相似文献   

10.
An HPLC method is described for the determination of amphetamine using fluorometric detection after derivatization with o-phthaldialdehyde and 3-mercaptopropionic acid. This procedure is more sensitive (detection limit 370 fmol in microdialysate buffer standards, 1.5 pmol in extracted plasma and tissue samples) than most of the previous methods described for the determination of amphetamine with HPLC-fluorescence detection. Due to the stability of the derivative it is also suitable for autosampling after manual derivatization. Investigators currently using o-phthaldialdehyde derivatization and fluorometric detection for amino acid determination should be able to rapidly implement this method.  相似文献   

11.
The leaves of Acacia species have been found to contain homoarginine, pipecolic acid and 4-hydroxy-pipecolic acid. The nymphs of the tree locust Anacridium melanorhodon, which feed on the leaves of Acacia species, were not inhibited from feeding on palatable media containing concentrations of these amino acids equivalent to, or greater than, those found in the leaves. The graminivorous Locusta migratoria was more sensitive to these compounds, inhibitory effects being observed at concentrations comparable to those found in the leaves. The inhibitory effects of mixtures of homoarginine and pipecolic acid were additive in A. melanorhodon but not in L. migratoria. Three of the non-protein amino acids found in the seeds of Acacia species, 2,3-diaminopropionic acid, 2-amino-3-acetylaminopropionic acid and 2-amino-3-oxalylaminopropionic acid, were more effective inhibitors of feeding in Anacridium than were the leaf amino acids.  相似文献   

12.
A new postcolumn derivatization method for the fluorometric determination of streptomycin in serum by high-performance liquid chromatography is described. The serum was treated with 3.5% perchloric acid to precipitate proteins and the supernatant was directly injected into the chromatograph. Streptomycin was separated by reversed-phase, ion-pair chromatography with a mobile phase containing ninhydrin as a fluorogenic reagent, octanesulfonate, and 1,2-ethanedisulfonate as counterions, and was detected by fluorescence using continuous-flow, postcolumn derivatization in an alkaline stream with ninhydrin in the mobile phase. This method is sensitive to 1.0 microgram/ml using only 100 microliter of serum. Comparison with a fluorescence polarization immunoassay gave a good correlation coefficient of 0.976.  相似文献   

13.
For the study of the derivatization behavior of aliphatic C1-C10 aldehydes with 2,4-dinitrophenylhydrazine (DNPH) in a heating block a gradient elution HPLC method for separation and determination by UV detection at 360 nm was applied. The influence of time, temperature, excess of reagent and stirring onto the reaction yields were examined for conducting the reaction in a thermostated heating block. First, the derivatization procedure had been screened by experiments according to a complete factorial design in order to evaluate the statistically significant variables. Those parameters were used to establish the optimum conditions for the reaction by means of a Box-Behnken design.  相似文献   

14.
A sensitive and accurate stable isotope dilution assay was developed for the measurement of pipecolic acid in body fluids using capillary gas chromatography with electron-capture detection. The method utilizes [2H11]pipecolic acid as the internal standard. Sample preparation consisted of derivatization in aqueous solution (pH 11.5) of the amine moiety with methyl chloroformate to the N-methylcarbamate, followed by acidic ethyl acetate extraction at pH ≤ 2 and further derivatization of the carboxyl moiety with pentafluorobenzyl bromide, the excess of which was removed by solid-phase extraction. Control values have been determined in the plasma of at-term infants, age > 1 week (n = 21, mean = 1.36 μM, range = 0.47–3.27 μM). The utility of the method was demonstrated by quantitating pipecolic acid in biological fluids derived from patients with peroxisomal disorders. The method was validated against an established electron-capture negative ion mass fragmentographic technique.  相似文献   

15.
Analysis of trace amino acids (AA) in physiological fluids has received more attention, because the analysis of these compounds could provide fundamental and important information for medical, biological, and clinical researches. More accurate method for the determination of those compounds is highly desirable and valuable. In the present study, we developed a selective and sensitive method for trace AA determination in biological samples using 2-[2-(7H-dibenzo [a,g]carbazol-7-yl)-ethoxy] ethyl chloroformate (DBCEC) as labeling reagent by HPLC-FLD-MS/MS. Response surface methodology (RSM) was first employed to optimize the derivatization reaction between DBCEC and AA. Compared with traditional single-factor design, RSM was capable of lessening laborious, time and reagents consumption. The complete derivatization can be achieved within 6.3 min at room temperature. In conjunction with a gradient elution, a baseline resolution of 20 AA containing acidic, neutral, and basic AA was achieved on a reversed-phase Hypersil BDS C18 column. This method showed excellent reproducibility and correlation coefficient, and offered the exciting detection limits of 0.19–1.17 fmol/μL. The developed method was successfully applied to determinate AA in human serum. The sensitive and prognostic index of serum AA for liver diseases has also been discussed.  相似文献   

16.
Application of a high-sensitivity microbore system designed to separate and quantify nonderivatized amino acids by anion exchange chromatography and amperometric detection for determination of amino acid-specific activities in biological samples requires high capacity to recover sufficient labeled material for adequate count statistics. Scale up from a low (25-1000 pmol) to a high (500-15,000 pmol) working range was achieved by use of a thick working electrode gasket to reduce sensitivity and eliminate peak splitting and tailing and by modification of the wash procedure to eliminate carryover. Analysis of recoveries of labeled amino acids revealed that specific amino acids are either selectively retained on the column or partially degraded during analysis and that assessment of purities of labeled compounds and metabolic labeling patterns requires careful analysis of recoveries of labeled compounds in the appropriate eluate fraction.  相似文献   

17.
18.
All cysteine and cystine in a protein are derivatized during hydrolysis in hydrochloric acid containing 3,3'-dithiodipropionic acid. The resulting derivative can be separated from other amino acids and used for quantitation of cysteine plus half-cystine. A procedure is presented for accurate determination by ion exchange chromatography and postcolumn derivatization of all amino acids from acid hydrolysis of a protein, including the Cys-derivative.  相似文献   

19.
With the further improvement of food safety requirements, the development of fast, highly sensitive, and portable methods for the determination of foodborne hazardous substances has become a new trend in the food industry. In recent years, biosensors and platforms based on functional nucleic acids, along with a range of signal amplification devices and methods, have been established to enable rapid and sensitive determination of specific substances in samples, opening up a new avenue of analysis and detection. In this paper, functional nucleic acid types including aptamers, deoxyribozymes, and G-quadruplexes which are commonly used in the detection of food source pollutants are introduced. Signal amplification elements include quantum dots, noble metal nanoparticles, magnetic nanoparticles, DNA walkers, and DNA logic gates. Signal amplification technologies including nucleic acid isothermal amplification, hybridization chain reaction, catalytic hairpin assembly, biological barcodes, and microfluidic system are combined with functional nucleic acids sensors and applied to the detection of many foodborne hazardous substances, such as foodborne pathogens, mycotoxins, residual antibiotics, residual pesticides, industrial pollutants, heavy metals, and allergens. Finally, the potential opportunities and broad prospects of functional nucleic acids biosensors in the field of food analysis are discussed.  相似文献   

20.
Examination of the extent of production of the ninhydrin-colored derivative, Ruhemann's purple, under automated conditions of a single-column amino acid analyzer by several classes of sulfur-containing amino acids revealed a wide variation in the color factors relative to leucine. These ranged from 0.02 for the methyl ester of cysteine to 2.19 for D-homocystine. Color yields obtained by the manual ninhydrin reaction are generally lower than the corresponding values obtained on the amino acid analyzer. The elution positions ranged from 5.12 min for cysteic acid to 84.9 min for l-cystine dimethyl ester. The observed behavior of these compounds in the ninhydrin reaction is rationalized in terms of structural and electronic factors which they exhibit in reacting with ninhydrin to form the visible dye. Such an analysis should make it possible to predict ninhydrin color factors, and possibly also elution times, of structurally related compounds.  相似文献   