首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
Development of an automated procedure for fluorescent DNA sequencing   总被引:3,自引:0,他引:3  
We describe here the development of a procedure for complete automation of the dideoxynucleotide DNA sequencing chemistry using fluorescent dye-labeled oligonucleotide primers. This procedure combines rapid preparation of template DNA using a modification of the polymerase chain reaction, automation of the DNA sequencing reactions using a robotic laboratory workstation, and subsequent analysis of the fluorescent-labeled reaction products on a commercial automated fluorescent sequencer. Using this procedure, we were able to produce sufficient quantities of template DNA directly from bacterial colonies or bacteriophage plaques, perform the DNA sequencing reactions on these templates, and load the reaction products on the fluorescent DNA sequencer in a single work day. This scheme for automation of the fluorescent DNA sequencing method allows the fluorescent sequencer to be run at its full capacity every day and eliminates much of the labor required to obtain a high level of data output. Currently, we are able to perform and analyze 16 fluorescent-labeled reactions every day, with an average output of over 7000 bp per sequencer run.  相似文献   

3.
4.
Automated fluorescence sequencing depends on high-quality plasmid DNA, which is conveniently prepared by minipreparation procedures. While those procedures are effective for high-copy number plasmids, purity and yields of low-copy number plasmids are often not sufficient to achieve reasonable sequencing results. Here, we describe a reproducible and cheap procedure for the small-scale preparation of plasmid DNA, which is based on the original Holmes and Quigley protocol, comprising a boiling and two selective precipitation steps. Besides various other modifications, this procedure utilizes polyethylene glycol (PEG) precipitation as a key step to further purify plasmid DNA tailored to automated fluorescence sequencing. Independent of the plasmid size and copy number, the modified procedure yields plasmid DNA, which gives average reading lengths of 800 and more bases with a standard fluorescence cycle sequencing protocol. To demonstrate the efficiency and reproducibility of the method, sequencing data of various human interleukin-6 gene variants cloned in different vectors are presented. This procedure offers an economical alternative to commercial miniprep kits, utilizing silica resins or anion-exchanger matrices and, moreover, is more reliable and consistent with respect to reading lengths and accuracy in automated fluorescence sequencing.  相似文献   

5.
In an effort to find a simple and inexpensive purification method of polymerase chain reaction (PCR) reaction before cycle sequencing reaction, we compared a commercial system with a precipitation protocol performed in our laboratory. We found that, particularly with small PCR products, our method works with greater success than the method compared. Our precipitation method may be used on a larger PCR fragment before cycle sequencing reaction as well. Furthermore, it has the advantage of being simple as the well-known dilution method; in contrast to the dilution method, the precipitation method removes excess primers as well as possible primer dimers.  相似文献   

6.
DNA sequencing separations of standard DNA fragments of known sequence have been achieved in small diameter capillary gels electrophoresed and analyzed in parallel in a modified commercial DNA sequencer instrument. DNA sequencing in terms of base-calling accuracy is comparable to conventional slab gels; however, the separations in the capillary were performed somewhat faster and required less sample than those in the slab gel. Advantages of this approach vs. separations on conventional slab gels are discussed.  相似文献   

7.
Pyrimidine-specific chemical reactions useful for DNA sequencing.   总被引:48,自引:39,他引:48       下载免费PDF全文
Potassium permanganate reacts selectively with thymidine residues in DNA (1) while hydroxylamine hydrochloride at pH 6 specifically attacks cytosine (2). We have adopted these reactions for use with the chemical sequencing method developed by Maxam and Gilbert (3).  相似文献   

8.
9.
Automated fluorescence-based DNA sequence analysis offers the possibility to undertake very large scale sequencing projects. Directed strategies, such as the specific-primer-directed sequencing approach ('gene walking'), should prove useful in such projects. Described herein is a study involving the use of this approach in conjunction with automated fluorescence detection on a commercial instrument (ABI 370A DNA sequencer). This includes procedures for the rapid chemical synthesis and purification of labeled primers, the design of primer sequences that are compatible with the commercial analysis software, and automated DNA sequence analysis using such primers. A set of four fluorophore-labeled primers can be reliably synthesized in a twenty-four hour period, and greater than 300 nucleotides of analyzed new sequence obtained using this set in an additional twenty-four hours. Scale-up of these procedures to take advantage of the full capabilities of the sequencer is, at present, too slow and costly to be suitable for routine sequencing, and therefore the use of specific-primers is best suited to the closure of gaps in extended sequence produced using random cloning and sequencing strategies.  相似文献   

10.
A cost-effective, reliable, and reproducible method has been developed to produce good-quality, double-stranded plasmid DNA for automated sequence analysis. The method incorporates modifications to a previously described plasmid-purification protocol used in manual sequencing. The quality of the DNA produced from the present protocol is suitable for automated fluorescent sequencing. Using a dye-terminator sequencing protocol, most runs using plasmid DNA prepared using this protocol produced over 700 bases with greater than 99% base-calling accuracy.  相似文献   

11.
T7 DNA polymerase in automated dideoxy sequencing.   总被引:6,自引:2,他引:6       下载免费PDF全文
T7 DNA polymerase with chemically inactivated 3'-5' exo-nuclease activity, as well as unmodified T7 DNA polymerase, were used for sequencing by the dideoxy method in an automated system with fluorescence labelled primer and on-line detection of laser-excited reaction products. An analysis of signal intensity variations in the C track revealed that low C signals were usually preceded by a T in the sequence. This effect was modified by surrounding nucleotides. Signal intensities were more uniform with T7 polymerase than with the Klenow fragment of DNA polymerase I. Some sequences ambiguous with the Klenow enzyme could easily be evaluated with the T7 enzyme. One sequence could only be read by the unmodified T7 polymerase, while both the Klenow fragment and the chemically modified T7 enzyme gave uninterpretable data.  相似文献   

12.
13.
For the advancement of Human Genome Project, we have developed an automated DNA sequencing system HUGA-I. It is composed of several automated instruments and transfer robots connecting them. In this paper we describe the results of the performance evaluation test of HUGA-I. Although some of the system units showed good performances, the total performance of the HUGA-I was about 1/6 of the designed value. By revealing principal reasons of this poor performance, we would like to contribute to the automation in genome analysis, particularly in human genome analysis.Since the sequence technology advanced remarkably in these years, the system units of HUGA-I become older than those which are now commercially available and the throughput of it is out of our expectations. Nevertheless, we believe that it is meaningful to introduce the exact performance of HUGA-I and present the bottle neck points in the automating sequencing processes. Because, automation in the gene analysis is ultimately important, in particular for the analysis of large genomes such as the human genome. The aims of this paper are to introduce the results in performance evaluation of HUGA-I and to elucidate the bottle neck points in the automation of sequencing processes.The authors express their sincere thanks to Mr. Morisada Hayakawa and Mrs. Nobuko Kato for their technical asistance.  相似文献   

14.
15.
16.
A rapid, robust and sensitive method has been developed for the amplification and direct sequencing of human mitochondrial DNA. A 403-bp hypervariable segment was amplified by two successive rounds of nested PCR. This was then sequenced by the dideoxy chain termination method using dye-labeled universal sequencing primers in conjunction with an automated DNA sequencer. This paper describes the assessment of four different strategies for this amplification and sequencing process. Optimal results were obtained by immobilizing the biotinylated PCR product on Dynabeads followed by solid-phase sequencing with Sequenase. Degraded samples and those containing trace amounts of DNA such as extracts from hair shafts can be analyzed by this method.  相似文献   

17.
An improved DNA sequencing strategy   总被引:42,自引:0,他引:42  
A modification of Hong's systematic DNA sequencing strategy is described. The original procedure has been simplified and transfectant yield increased. After DNase I limited cleavage in the presence of Mn2+, the single-cut linear DNA does not have to be separated from supercoiled or open circular DNA on an agarose gel. After ligation, the DNA is digested with a second restriction endonuclease for which a unique cleavage site resides between the insert and the first restriction endonuclease cutting site. The original intact DNA is linearized whereas the deleted subclone is not. The background is decreased to an undetectable level. This DNA sequencing strategy was tested on a 1.4-kb DNA fragment containing the araC regulatory gene from Erwinia carotovora. A set of subclones sufficient to sequence the fragment on both strands was produced in 2 days and the yield was at least 60-fold higher than in the original protocol.  相似文献   

18.
An efficient method for sequencing PCR amplified DNA   总被引:4,自引:0,他引:4  
  相似文献   

19.
Procedures are presented for reliable and accurate nucleotide sequence analysis using as template supercoiled DNA prepared by a modified rapid boiling minipreparation protocol. This method yields DNA templates suitable for sequencing within 1 h of bacterial harvest. We describe optimal reaction conditions for supercoiled miniprep DNA sequencing using a modified T7 DNA polymerase (Sequenase) in dideoxynucleotide chain termination reactions. We demonstrate that under these conditions, the sequencing data obtained with miniprep DNA is indistinguishable from that obtained with CsCl purified supercoiled DNA or from that obtained using single stranded DNA templates. We further show that the supercoiled DNA sequencing reactions can be analyzed on a commercially available automated DNA sequencing system that detects 32P labeled DNA during its electrophoretic separation. Taken together, these developments represent a significant improvement in the process of nucleotide sequence analysis.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号