首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

This paper presents the development of a detailed articulating three-dimensional finite-element model of the human knee, derived from MRI scan images. The model utilises precise material models and many contact interfaces in order to produce a realistic kinematic response. The behaviour of the model was examined within two fields of biomechanical simulations: general life and car-crash. These simulations were performed with the non-linear explicit dynamic code PAM-SAFE?. The knee model produced results that compared favourably with existing literature. Such a model (together with other joint models that could be constructed using the same techniques) would be a valuable tool for examining new designs of prosthesis and mechanisms of injury.  相似文献   

2.
The cost and time efficiency of computational polyethylene wear simulations may enable the optimization of total knee replacements for the reduction of polyethylene wear. The present study proposes an energy dissipation wear model for polyethylene which considers the time dependent molecular behavior of polyethylene, aspects of tractive rolling and contact pressure. This time dependent – energy dissipation wear model was evaluated, along with several other wear models, by comparison to pin-on-disk results, knee simulator wear test results under various kinematic conditions and knee simulator wear test results that were performed following the ISO 14243-3 standard. The proposed time dependent – energy dissipation wear model resulted in improved accuracy for the prediction of pin-on-disk and knee simulator wear test results compared with several previously published wear models.  相似文献   

3.
IntroductionMusculoskeletal modeling allows insight into the interaction of muscle force and knee joint kinematics that cannot be measured in the laboratory. However, musculoskeletal models of the lower extremity commonly use simplified representations of the knee that may limit analyses of the interaction between muscle forces and joint kinematics. The goal of this research was to demonstrate how muscle forces alter knee kinematics and consequently muscle moment arms and joint torque in a musculoskeletal model of the lower limb that includes a deformable representation of the knee.MethodsTwo musculoskeletal models of the lower limb including specimen-specific articular geometries and ligament deformability at the knee were built in a finite element framework and calibrated to match mean isometric torque data collected from 12 healthy subjects. Muscle moment arms were compared between simulations of passive knee flexion and maximum isometric knee extension and flexion. In addition, isometric torque results were compared with predictions using simplified knee models in which the deformability of the knee was removed and the kinematics at the joint were prescribed for all degrees of freedom.ResultsPeak isometric torque estimated with a deformable knee representation occurred between 45° and 60° in extension, and 45° in flexion. The maximum isometric flexion torques generated by the models with deformable ligaments were 14.6% and 17.9% larger than those generated by the models with prescribed kinematics; by contrast, the maximum isometric extension torques generated by the models were similar. The change in hamstrings moment arms during isometric flexion was greater than that of the quadriceps during isometric extension (a mean RMS difference of 9.8 mm compared to 2.9 mm, respectively).DiscussionThe large changes in the moment arms of the hamstrings, when activated in a model with deformable ligaments, resulted in changes to flexion torque. When simulating human motion, the inclusion of a deformable joint in a multi-scale musculoskeletal finite element model of the lower limb may preserve the realistic interaction of muscle force with knee kinematics and torque.  相似文献   

4.
Concurrent multiscale simulation strategies are required in computational biomechanics to study the interdependence between body scales. However, detailed finite element models rarely include muscle recruitment due to the computational burden of both the finite element method and the optimization strategies widely used to estimate muscle forces. The aim of this study was twofold: first, to develop a computationally efficient muscle force prediction strategy based on proportional-integral-derivative (PID) controllers to track gait and chair rise experimental joint motion with a finite element musculoskeletal model of the lower limb, including a deformable knee representation with 12 degrees of freedom; and, second, to demonstrate that the inclusion of joint-level deformability affects muscle force estimation by using two different knee models and comparing muscle forces between the two solutions. The PID control strategy tracked experimental hip, knee, and ankle flexion/extension with root mean square errors below 1°, and estimated muscle, contact and ligament forces in good agreement with previous results and electromyography signals. Differences up to 11% and 20% in the vasti and biceps femoris forces, respectively, were observed between the two knee models, which might be attributed to a combination of differing joint contact geometry, ligament behavior, joint kinematics, and muscle moment arms. The tracking strategy developed in this study addressed the inevitable tradeoff between computational cost and model detail in musculoskeletal simulations and can be used with finite element musculoskeletal models to efficiently estimate the interdependence between muscle forces and tissue deformation.  相似文献   

5.
Musculoskeletal modeling and simulations have vast potential in clinical and research fields, but face various challenges in representing the complexities of the human body. Soft tissue artifact from skin-mounted markers may lead to non-physiological representation of joint motions being used as inputs to models in simulations. To address this, we have developed adaptive joint constraints on five of the six degree of freedom of the knee joint based on in vivo tibiofemoral joint motions recorded during walking, hopping and cutting motions from subjects instrumented with intra-cortical pins inserted into their tibia and femur. The constraint boundaries vary as a function of knee flexion angle and were tested on four whole-body models including four to six knee degrees of freedom. A musculoskeletal model developed in OpenSim simulation software was constrained to these in vivo boundaries during level gait and inverse kinematics and dynamics were then resolved. Statistical parametric mapping indicated significant differences (p < 0.05) in kinematics between bone pin constrained and unconstrained model conditions, notably in knee translations, while hip and ankle flexion/extension angles were also affected, indicating the error at the knee propagates to surrounding joints. These changes to hip, knee, and ankle kinematics led to measurable changes in hip and knee transverse plane moments, and knee frontal plane moments and forces. Since knee flexion angle can be validly represented using skin mounted markers, our tool uses this reliable measure to guide the five other degrees of freedom at the knee and provide a more valid representation of the kinematics for these degrees of freedom.  相似文献   

6.
Simulation models of quiet standing have been developed to study the potential use of closed-loop stimulation orthoses in mid-thoracic spinal cord injury. The first model (static) consists of a multi-link inverted pendulum. The second model (dynamic) consists of a single-link inverted pendulum, with electrically stimulated muscles providing balancing activation at the ankle joint and stabilization of the knee and hip joints. The initial simulations have shown that it may be possible to restore quiet standing in paraplegic individuals within certain limits subject to biomechanical constraints and to the available torque produced by the stimulated muscle.  相似文献   

7.
As fixation of cementless total knee replacement components during the first 4–6 weeks after surgery is crucial to establish bony ingrowth into the porous surface, several studies have quantified implant-bone micromotion. Relative motion between the tray and bone can be measured in vitro, but the full micromotion contour map cannot typically be accessed experimentally. Finite element models have been employed to estimate the full micromotion map, but have not been directly validated over a range of loading conditions. The goal of this study was to develop and validate computational models for the prediction of tray-bone micromotion under simulated activities of daily living. Gait, stair descent and deep knee bend were experimentally evaluated on four samples of a cementless tibial tray implanted into proximal tibial Sawbones™ constructs. Measurements of the relative motion between the tray and the anterior cortical shell were collected with digital image correlation and used to validate a finite element model that replicated the experiment. Additionally, a probabilistic analysis was performed to account for experimental uncertainty and determine model sensitivity to alignment and frictional parameters. The finite element models were able to distinguish between activities and capture the experimental trends. Best-matching simulations from the probabilistic analysis matched measured displacement with an average root mean square (RMS) difference of 14.3 µm and Pearson-product correlation of 0.93, while the mean model presented an average RMS difference of 27.1 µm and a correlation of 0.8. Maximum deviations from average experimental measurements were 40.5 and 87.1 µm for the best-matching and average simulations, respectively. The computational pipeline developed in this study can facilitate and enhance pre-clinical assessment of novel implant components.  相似文献   

8.
9.
In vitro pre-clinical testing of total knee replacement (TKR) devices is a necessary step in the evaluation of new implant designs. Whole joint knee simulators, like the Kansas knee simulator (KKS), provide a controlled and repeatable loading environment for comparative evaluation of component designs or surgical alignment under dynamic conditions. Experimental testing, however, is time and cost prohibitive for design-phase evaluation of tens or hundreds of design variations. Experimentally-verified computational models provide an efficient platform for analysis of multiple components, sizes, and alignment conditions. The purpose of the current study was to develop and verify a computational model of a dynamic, whole joint knee simulator. Experimental internal-external and valgus-varus laxity tests, followed by dynamic deep knee bend and gait simulations in the KKS were performed on three cadaveric specimens. Specimen-specific finite element (FE) models of posterior-stabilized TKR were created from magnetic resonance images and CAD geometry. The laxity data was used to optimize mechanical properties of tibiofemoral soft-tissue structures on a specimen-specific basis. Each specimen was subsequently analyzed in a computational model of the experimental KKS, simulating both dynamic activities. The computational model represented all joints and actuators in the experimental setup, including a proportional-integral-derivative (PID) controller to drive quadriceps actuation. The computational model was verified against six degree-of-freedom patellofemoral (PF) and tibiofemoral (TF) kinematics and actuator loading during both deep knee bend and gait activities, with good agreement in trends and magnitudes between model predictions and experimental kinematics; differences were less than 1.8 mm and 2.2° for PF and TF translations and rotations. The whole joint FE simulator described in this study can be applied to investigate a wide range of clinical and research questions.  相似文献   

10.
The popular Hill model for muscle activation and contractile dynamics has been extended with several different formulations for predicting the metabolic energy expenditure of human muscle actions. These extended models differ considerably in their approach to computing energy expenditure, particularly in their treatment of active lengthening and eccentric work, but their predictive abilities have never been compared. In this study, we compared the predictions of five different Hill-based muscle energy models in 3D forward dynamics simulations of normal human walking. In a data-tracking simulation that minimized muscle fatigue, the energy models predicted metabolic costs that varied over a three-fold range (2.45–7.15 J/m/kg), with the distinction arising from whether or not eccentric work was subtracted from the net heat rate in the calculation of the muscle metabolic rate. In predictive simulations that optimized neuromuscular control to minimize the metabolic cost, all five models predicted similar speeds, step lengths, and stance phase durations. However, some of the models predicted a hip circumduction strategy to minimize metabolic cost, while others did not, and the accuracy of the predicted knee and ankle angles and ground reaction forces also depended on the energy model used. The results highlights the need to clarify how eccentric work should be treated when calculating muscle energy expenditure, the difficulty in predicting realistic metabolic costs in simulated walking even with a detailed 3D musculoskeletal model, the potential for using such models to predict energetically-optimal gait modifications, and the room for improvement in existing muscle energy models and locomotion simulation frameworks.  相似文献   

11.
Combining musculoskeletal simulations with anatomical joint models capable of predicting cartilage contact mechanics would provide a valuable tool for studying the relationships between muscle force and cartilage loading. As a step towards producing multibody musculoskeletal models that include representation of cartilage tissue mechanics, this research developed a subject-specific multibody knee model that represented the tibia plateau cartilage as discrete rigid bodies that interacted with the femur through deformable contacts. Parameters for the compliant contact law were derived using three methods: (1) simplified Hertzian contact theory, (2) simplified elastic foundation contact theory and (3) parameter optimisation from a finite element (FE) solution. The contact parameters and contact friction were evaluated during a simulated walk in a virtual dynamic knee simulator, and the resulting kinematics were compared with measured in vitro kinematics. The effects on predicted contact pressures and cartilage–bone interface shear forces during the simulated walk were also evaluated. The compliant contact stiffness parameters had a statistically significant effect on predicted contact pressures as well as all tibio-femoral motions except flexion–extension. The contact friction was not statistically significant to contact pressures, but was statistically significant to medial–lateral translation and all rotations except flexion–extension. The magnitude of kinematic differences between model formulations was relatively small, but contact pressure predictions were sensitive to model formulation. The developed multibody knee model was computationally efficient and had a computation time 283 times faster than a FE simulation using the same geometries and boundary conditions.  相似文献   

12.
A key strength of computational modeling is that it can provide estimates of muscle, ligament, and joint loads, stresses, and strains through non-invasive means. However, simulations that can predict the forces in the muscles during activity while maintaining sufficient complexity to realistically represent the muscles and joint structures can be computationally challenging. For this reason, the current state of the art is to apply separate rigid-body dynamic and finite-element (FE) analyses in series. However, the use of two or more disconnected models often fails to capture key interactions between the joint-level and whole-body scales. Single framework MSFE models have the potential to overcome the limitations associated with disconnected models in series. The objectives of the current study were to create a multi-scale FE model of the human lower extremity that combines optimization, dynamic muscle modeling, and structural FE analysis in a single framework and to apply this framework to evaluate the mechanics of healthy knee specimens during two activities. Two subject-specific FE models (Model 1, Model 2) of the lower extremity were developed in ABAQUS/Explicit including detailed representations of the muscles. Muscle forces, knee joint loading, and articular contact were calculated for two activities using an inverse dynamics approach and static optimization. Quadriceps muscle forces peaked at the onset of chair rise (2174 N, 1962 N) and in early stance phase (510 N, 525 N), while gait saw peak forces in the hamstrings (851 N, 868 N) in midstance. Joint forces were similar in magnitude to available telemetric patient data. This study demonstrates the feasibility of detailed quasi-static, muscle-driven simulations in an FE framework.  相似文献   

13.
The relationship between obesity, weight gain and progression of knee osteoarthritis is well supported, suggesting that excessive joint loading may be a mechanism responsible for cartilage deterioration. Examining the influence of weight gain on joint compressive forces is difficult, as both muscles and ground reaction forces can have a significant impact on the forces experienced during gait. While previous studies have examined the relationship between body weight and knee forces, these studies have used models that were not validated using experimental data. Therefore, the objective of this study was to evaluate the relationship between changes in body weight and changes in knee joint contact forces for an individual's gait pattern using musculoskeletal modeling that is validated against known internal compressive forces. Optimal weighting constants were determined for three subjects to generate valid predictions of knee contact forces (KCFs) using in vivo data collection with instrumented total knee arthroplasty. A total of five simulations per walking trial were generated for each subject, from 80% to 120% body weight in 10% increments, resulting in 50 total simulations. The change in peak KCF with respect to body weight was found to be constant and subject-specific, predominantly determined by the peak force during the baseline condition at 100% body weight. This relationship may be further altered by any change in kinematics or body mass distribution that may occur as a result of a change in body weight or exercise program.  相似文献   

14.
It is unclear to what extent ballistic walking models can be used to qualitatively predict the swing phase at comfortable walking speed. Different study findings regarding the accuracy of the predictions of the swing phase kinematics may have been caused by differences in (1) kinematic input, (2) model characteristics (e.g. the number of segments), and (3) evaluation criteria. In the present study, the predictive validity of four ballistic swing phase models was evaluated and compared, that is, (1) the ballistic walking model as originally introduced by Mochon and McMahon, (2) an extended version of this model in which heel-off of the stance leg is added, (3) a double pendulum model, consisting of a two-segment swing leg with a prescribed hip trajectory, and (4) a shank pendulum model consisting of a shank and rigidly attached foot with a prescribed knee trajectory. The predictive validity was evaluated by comparing the outcome of the model simulations with experimentally derived swing phase kinematics of six healthy subjects. In all models, statistically significant differences were found between model output and experimental data. All models underestimated swing time and step length. In addition, statistically significant differences were found between the output of the different models. The present study shows that although qualitative similarities exist between the ballistic models and normal gait at comfortable walking speed, these models cannot adequately predict swing phase kinematics.  相似文献   

15.
Computational wear prediction is an attractive concept for evaluating new total knee replacement designs prior to physical testing and implementation. An important hurdle to such technology is the lack of in vivo contact pressure predictions. To address this issue, this study evaluates a computationally efficient simulation approach that combines the advantages of rigid and deformable body modeling. The hybrid method uses rigid body dynamics to predict body positions and orientations and elastic foundation theory to predict contact pressures between general three-dimensional surfaces. To evaluate the method, we performed static pressure experiments with a commercial knee implant in neutral alignment using flexion angles of 0, 30, 60, and 90 degrees and loads of 750, 1500, 2250, and 3000N. Using manufacturer CAD geometry for the same implant, an elastic foundation model with linear or nonlinear polyethylene material properties was implemented within a commercial multibody dynamics software program. The model's ability to predict experimental peak and average contact pressures simultaneously was evaluated by performing dynamic simulations to find the static configuration. Both the linear and nonlinear material models predicted the average contact pressure data well, while only the linear material model could simultaneously predict the trends in the peak contact pressure data. This novel modeling approach is sufficiently fast and accurate to be used in design sensitivity and optimization studies of knee implant mechanics and ultimately wear.  相似文献   

16.
Swing phase simulation and design of above knee prostheses   总被引:1,自引:0,他引:1  
A detailed dynamic model of the stump-prosthesis system for an above knee amputee was developed. The model was used to examine the influence of controls and design parameters on the limb system performance during the swing phase of gait. The model duplicated the clinically known fact that hydraulic knee controllers allow the amputee to change walking speed while mechanical knee controllers limit the amputee to a single walking speed. Contrary to current practice, the simulations suggest that light weight prosthesis designs do not perform as well as heavier designs. A simple design based on a constant friction knee is shown to yield good overall performance.  相似文献   

17.
Musculoskeletal simulations are used in many different applications, ranging from the design of wearable robots that interact with humans to the analysis of patients with impaired movement. Here, we introduce OpenSim Moco, a software toolkit for optimizing the motion and control of musculoskeletal models built in the OpenSim modeling and simulation package. OpenSim Moco uses the direct collocation method, which is often faster and can handle more diverse problems than other methods for musculoskeletal simulation. Moco frees researchers from implementing direct collocation themselves—which typically requires extensive technical expertise—and allows them to focus on their scientific questions. The software can handle a wide range of problems that interest biomechanists, including motion tracking, motion prediction, parameter optimization, model fitting, electromyography-driven simulation, and device design. Moco is the first musculoskeletal direct collocation tool to handle kinematic constraints, which enable modeling of kinematic loops (e.g., cycling models) and complex anatomy (e.g., patellar motion). To show the abilities of Moco, we first solved for muscle activity that produced an observed walking motion while minimizing squared muscle excitations and knee joint loading. Next, we predicted how muscle weakness may cause deviations from a normal walking motion. Lastly, we predicted a squat-to-stand motion and optimized the stiffness of an assistive device placed at the knee. We designed Moco to be easy to use, customizable, and extensible, thereby accelerating the use of simulations to understand the movement of humans and other animals.  相似文献   

18.
When car crash experiments are performed using cadavers or dummies, the active muscles' reaction on crash situations cannot be observed. The aim of this study is to estimate muscles' response of the major muscle groups using three-dimensional musculoskeletal model by dynamic simulations of low-speed sled-impact. The three-dimensional musculoskeletal models of eight subjects were developed, including 241 degrees of freedom and 86 muscles. The muscle parameters considering limb lengths and the force-generating properties of the muscles were redefined by optimization to fit for each subject. Kinematic data and external forces measured by motion tracking system and dynamometer were then input as boundary conditions. Through a least-squares optimization algorithm, active muscles' responses were calculated during inverse dynamic analysis tracking the motion of each subject. Electromyography for major muscles at elbow, knee, and ankle joints was measured to validate each model. For low-speed sled-impact crash, experiment and simulation with optimized and unoptimized muscle parameters were performed at 9.4 m/h and 10 m/h and muscle activities were compared among them. The muscle activities with optimized parameters were closer to experimental measurements than the results without optimization. In addition, the extensor muscle activities at knee, ankle, and elbow joint were found considerably at impact time, unlike previous studies using cadaver or dummies. This study demonstrated the need to optimize the muscle parameters to predict impact situation correctly in computational studies using musculoskeletal models. And to improve accuracy of analysis for car crash injury using humanlike dummies, muscle reflex function, major extensor muscles' response at elbow, knee, and ankle joints, should be considered.  相似文献   

19.
Component mal-alignment in total knee arthroplasty has been associated with increased revision rates and poor clinical outcomes. A significant source of variability in traditional, jig-based total knee arthroplasty is the performance of the surgeon. The purpose of this study was to determine the most sensitive steps in the femoral and tibia arthroplasty procedures. A computational model of the total knee arthroplasty procedure was created, and Monte Carlo simulations were performed that included surgeon variability in each step of the procedure. The proportion of well-aligned components from the model agrees with clinical literature in most planes. When components must be aligned within ±3° in all planes, component alignment was most sensitive to the accuracy of identifying the lateral epicondyle for the femoral component, and to the precision of the transverse plane alignment of the extramedullary guide for the tibial component. This model can be used as a tool for evaluating different procedural approaches or sources of variability to improve the quality of the total knee arthroplasty procedure.  相似文献   

20.
Biomechanical models are sensitive to the choice of model parameters. Therefore, determination of accurate subject specific model parameters is important. One approach to generate these parameters is to optimize the values such that the model output will match experimentally measured strength curves. This approach is attractive as it is inexpensive and should provide an excellent match to experimentally measured strength. However, given the problem of muscle redundancy, it is not clear that this approach generates accurate individual muscle forces. The purpose of this investigation is to evaluate this approach using simulated data to enable a direct comparison. It is hypothesized that the optimization approach will be able to recreate accurate muscle model parameters when information from measurable parameters is given. A model of isometric knee extension was developed to simulate a strength curve across a range of knee angles. In order to realistically recreate experimentally measured strength, random noise was added to the modeled strength. Parameters were solved for using a genetic search algorithm. When noise was added to the measurements the strength curve was reasonably recreated. However, the individual muscle model parameters and force curves were far less accurate. Based upon this examination, it is clear that very different sets of model parameters can recreate similar strength curves. Therefore, experimental variation in strength measurements has a significant influence on the results. Given the difficulty in accurately recreating individual muscle parameters, it may be more appropriate to perform simulations with lumped actuators representing similar muscles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号