1.
A fluorescent glucose biosensor was constructed by immobilizing glucose oxidase on a bamboo inner shell membrane with glutaraldehyde as a cross-linker. The detection scheme was based on the depletion of dissolved oxygen content upon exposure to glucose solution with a concomitant increase in the fluorescence intensity of an oxygen transducer, tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(Pi) ditetrakis(4-chlorophenyl)borate. The enzyme immobilization, effect of pH, temperature and ionic strength have been studied in detail. The biosensor exhibited repeatable response to a 2.0 mM glucose solution with a relative standard deviation of 3.0% (n = 10). It showed good storage stability and maintained 95% of its initial response after it had been kept at 4 degrees C for 8 months. The biosensor has a linear response range of 0.0-0.6 mM glucose with a detection limit of 58 microM (S/N = 3). Common potential interferants in samples do not pose any significant interference on the response of the glucose biosensor. It was successfully applied to the determination of glucose content in some commercial wines and medical glucose injections.  相似文献   

2.
Four different ionic liquids, based on dialkylimidazolium cations associated with perfluorinated and bis(trifluoromethyl)sulfonyl amide anions were used as reaction media for butyl butyrate synthesis catalyzed by free Candida antarctica lipase B at 2% (v/v) water content and 50 °C. Lipase had enhanced synthetic activity in all ionic liquids in comparison with two organic solvents (hexane, and 1-butanol), the enhanced activity being related to the increase in polarity of ionic liquids. The continuous operation of lipase with all the assayed ionic liquids showed over-stabilization of the enzyme. The reuse of free lipase in 1-butyl-3-methylimidazolium hexafluorophosphate in continuous operation cycles showed a half-life time 2300 times greater than that observed when the enzyme was incubated in the absence of substrate (3.2 h), and a selectivity higher than 90%.  相似文献   

3.
An enzymatic biosensor was fabricated by the covalent immobilization of pyruvate oxidase (PyO) onto the nano-particle comprised poly-5,2':5',2'-terthiophene-3'-carboxylic acid, poly-TTCA (nano-CP) layers on a glassy carbon electrode (GCE) for the amperometric detection of the phosphate ions. The direct electron transfer reaction of the immobilized PyO onto the nano-CP layers was investigated and the electron transfer rate constant was determined to be 0.65 s(-1). The electrochemically prepared nano-CP lowered the oxidation potential (+0.40 V versus Ag/AgCl) of an enzymatically generated H(2)O(2) by PyO in a phosphate solution. Experimental parameters affecting the sensitivity of the biosensors, such as amounts of the cofactors, the pH, the applied potential, and the temperature were optimized. A linear response for the detection of the phosphate ion was observed between 1.0 microM and 100 microM and the detection limit was determined to be about 0.3 microM. The response time of the biosensors was about 6s. The biosensor showed good selectivity towards other interfering anions. The long-term storage stability of the phosphate biosensor was studied and the sensor was applied in a human serum sample for the phosphate ions detection.  相似文献   

4.
A biosensor for the detection of triazine- and phenylurea-type herbicides was constructed using isolated Photosystem II (PS II) complexes as a biosensing element. PSII isolated from the thermophilic cyanobacterium Synechococcus elongatus was immobilized on the surface of a screen-printed sensor composed of a graphite working electrode and Ag/AgCl reference electrode deposited on a polymeric substrate. The biosensor was mounted in a flow microcell with illumination. The principle of the detection was based on the fact that herbicides selectively block PSII electron transport activity in a concentration-dependent manner. Changes of the activity were registered amperometrically as the rate of photoreduction of an artificial electron acceptor. The setup resulted in a reusable herbicide biosensor with a good stability (half-life of 24 h) and limit of detection of approximately 10(-9) M for diuron, atrazine and simazine.  相似文献   

5.
A novel, low potential and highly sensitive acetylcholinesterase (AChE) biosensor was developed based on 1-butyl-3-methylimidazolium tetrafluoroborate/multiwalled carbon nanotube composite gel thiocholine sensor. Composite gel promoted electron transfer reaction at a lower potential (+50 mV) and catalyzed electrochemical oxidation of thiocholine with high sensitivity. AChE was immobilized in sol-gel matrix that provides a good support for enzyme without any inhibition effect from the ionic liquid. The amount of immobilized enzyme and incubation time with chlorpyrifos were optimized. Chlorpyrifos could be determined in the range of 10(-8)-10(-6)M with a detection limit of 4 nM. Fast and efficient enzyme reactivation was obtained at low obidoxime concentration (0.1mM). Moreover, the biosensor exhibited a good stability and reproducibility and could be use for multiple determinations of pesticide with no loss of the enzyme activity.  相似文献   

6.
A conductometric biosensor for nitrite detection was developed using cytochrome c nitrite reductase (ccNiR) extracted from Desulfovibrio desulfuricans ATCC 27774 cells immobilized on a planar interdigitated electrode by cross-linking with saturated glutaraldehyde (GA) vapour in the presence of bovine serum albumin, methyl viologen (MV), Nafion, and glycerol. The configuration parameters for this biosensor, including the enzyme concentration, ccNiR/BSA ratio, MV concentration, and Nafion concentration, were optimized. Various experimental parameters, such as sodium dithionite added, working buffer solution, and temperature, were investigated with regard to their effect on the conductance response of the biosensor to nitrite. Under the optimum conditions at room temperature (about 25 degrees C), the conductometric biosensor showed a fast response to nitrite (about 10s) with a linear range of 0.2-120 microM, a sensitivity of 0.194 microS/microM [NO(2)(-)], and a detection limit of 0.05 microM. The biosensor also showed satisfactory reproducibility (relative standard deviation of 6%, n=5). The apparent Michaelis-Menten constant (K(M,app)) was 338 microM. When stored in potassium phosphate buffer (100mM, pH 7.6) at 4 degrees C, the biosensor showed good stability over 1 month. No obvious interference from other ionic species familiar in natural waters was detected. The application experiments show that the biosensor is suitable for use in real water samples.  相似文献   

7.
The paper describes a novel conductometric biosensor sensitive to cadmium ions based on alkaline phosphatase immobilized on gold planar microelectrodes used as transducers. Assays have been carried out with paranitrophenyl phosphate as substrate for the immobilized enzyme. Various parameters such as reticulation time, along with pH, ionic strength and buffer concentration of the measuring solution were studied. The optimized biosensor was stable, reproducible and it exhibited a detection limit of 4.45 microM for cadmium ions.  相似文献   

8.
A novel biosensor for homocysteine determination has been developed. The biosensor was fabricated with l-homocysteine desulfhydrase immobilized on the ammonium selective electrode by means of eggshell membrane. The measurement principle is based on determination of ammonia due to the enzymatic reaction in the medium by ammonium selective electrode. The effects of enzyme loading, glutaraldehyde concentration, pH, buffer concentration, temperature, dithiotreitol (DTT) concentration and ionic strength adjustment buffer (ISA) on the biosensor response were investigated in detail. The linear detection range and limit of detection (LOD) for homocysteine were found to be 0.15–1.8 mM and 55 μM, respectively. Finally, the homocysteine biosensor has been applied to plasma samples for determination of total homocysteine contents.  相似文献   

9.
A screen-printed carbon electrode (SPCE) incorporating the electrocatalyst cobalt phthalocyanine (CoPC), fabricated using a water-based ink formulation, has been investigated as the base transducer for a uric acid biosensor. A sandwich biosensor was fabricated by first depositing cellulose acetate (CA) onto this transducer (CoPC-SPCE), followed by uricase (UOX) and finally a polycarbonate (PC) membrane; this device is designated PC-UOX-CA-CoPC-SPCE. This biosensor was used in conjunction with chronoamperometry to optimize the conditions for the analysis of urine: temperature, 35°C; buffer, pH 9.2; ionic strength, 50 mM; uricase, 0.6 U; incubation time, 180 s. The proposed biosensor was applied to urine from a healthy subject. The precision determined on unspiked urine (n=6) was 5.82%. Urine was fortified with 0.225 mM UA, and the resulting precision and recovery were 4.21 and 97.3%, respectively. The linear working range of the biosensor was found to be 0.015 to 0.25 mM (the former represents the detection limit), and the sensitivity was calculated to be 2.10 μA/mM.  相似文献   

10.
The development of an amperometric enzyme-based sensor for chromate (CrO(4)(2-)) quantification in ground waters was investigated. Crucial physical and chemical factors characterising ground waters were tested for their influence or interference on chromate quantification: pH (7.6-8.5), temperature (9-25 degrees C), ionic strength (0-0.2M), oxygen, metals, bicarbonate and sulphate. The biosensor's response was dependent on temperature and pH as sensitivity increased with temperature and was higher at pH 7.6 than at pH 8.5. Sensitivity decreased with ionic strength until 0.1M, and was stable for higher values. Dissolved oxygen did not allow chromate quantification when it was present, but O(2) could be eliminated by adding Na(2)SO(3) or bubbling nitrogen gas into the solution. Bicarbonate did not interfere with chromate quantification by the biosensor. Sulphate was detected with a detection threshold 80 times higher than that of chromate and a lower sensitivity. Several metals (V(V), W(VI), Mn(VII), Mo(VI)) similar to chromate due to their oxidative properties and structure (oxyanions) were tested as possible interfering compounds. The sensitivity of the biosensor for these metals was low and the detection level was 30 times higher than that of chromate. These metal concentrations are usually weaker than chromate concentration in polluted ground waters so that dilution of the sample should allow chromate quantification by the biosensor. This study shows that the cytochrome c(3)-based sensor can detect compounds other than chromate but with a lower sensitivity. Although non-specific for the detection of chromate, it can however be adapted and used for the quantification of chromate in ground waters containing low sulphate concentration.  相似文献   

11.
The selective precipitation of xylanase from an aqueous phase containing mixtures of xylanase and cellulase was studied using an ionic surfactant as precipitating ligand and a polar organic solvent as recovery solvent. Of four ionic surfactants tested, sodium di-(2-ethylhexyl) sulfosuccinate (AOT) showed a complete removal of xylanase at pH 4.5. The recovery of xylanase from the xylanase-AOT complex was a strong function of the type and the volume of the polar solvent and of the concentration of sodium acetate buffer in the final aqueous solution used to solubilize the recovered xylanase. With ethanol as a recovery solvent, a recovery of xylanase activity of 78 +/- 10% was obtained. The cellulase activity in the recovered xylanase was below the detection limit. The results demonstrate that an ionic surfactant can recover enzymes from aqueous solutions without loss in their activity.  相似文献   

12.
A highly sensitive biosensor was developed based on bionanomultilyer with water-soluble carbon nanotubes (CNTs). The water-soluble poly(allylamine hydrochloride)-wrapped multiwall carbon nanotubes (PAH-MWNTs) can be obtained for the first time relying on the function of barbiturates, which provides a useful avenue for CNT application in material science and biosensor technology. Based on this, the PAH-MWNTs/horseradish peroxidase (HRP) bionanomultilayer was prepared via layer-by-layer (LBL) assembly. Electrochemical impedance spectroscopy, atomic force microscopy and UV-vis spectra were adopted to monitor the uniform LBL assembly of the homogeneous bionanomultilayer. The bionanomultilayer was used to construct a phenolic biosensor. Under the optimal conditions, the biosensor presented a linear response for catechol from 0.1 to 20.4muM, with a detection limit of 0.06muM. A series of phenolics were detected by the bionanomultilayer biosensor. The introduced MWNTs in the biosensor provided a suitable microenvironment to retain the HRP activity and acted as a transducer for amplifying the electrochemical signal of the product of the enzymatic reaction. So the developed bionanomultilayer biosensor exhibited a fast, sensitive and stable detection.  相似文献   

13.
A glucose amperometric biosensor based on the immobilization of glucose oxidase (GOx) in microparticles prepared by polymerization of the ionic liquid 1-vinyl-3-ethyl-imidazolium bromide (ViEtIm+Br) using the concentrated emulsion polymerization method has been developed. The polymerization of the emulsion dispersed phase, in which the enzyme was dissolved together with the ionic liquid monomer, provides poly(ViEtIm+Br) microparticles with entrapped GOx. An anion-exchange reaction was carried out for synthesizing new microparticles of poly(ViEtIm+(CF3SO2)2N) and poly(ViEtIm+BF4). The enzyme immobilization method was optimized for biosensor applications and the following optimal values were determined: pH 4.0 for the synthesis medium, 1.23 M monomer concentration and 3.2% (w/w) cross-linking content. The performance of the biosensor as a function of some analytical parameters such as pH and temperature of the measuring medium, and enzymatic load of the microparticles was also investigated. The effect of the substances which are present in serum samples such as uric and ascorbic acid was eliminated by using a thin Nafion layer covering the electrode surface. The biosensor thus prepared can be employed in aqueous and in non-aqueous media with satisfactory results for glucose determination in human serum samples. The useful lifetime of this biosensor was 150 days.  相似文献   

14.
In the present work, an amperometric inhibition biosensor for the determination of sulfide has been fabricated by immobilizing Coprinus cinereus peroxidase (CIP) on the surface of screen printed electrode (SPE). Chitosan/acrylamide was applied for immobilization of peroxidase on the working electrode. The amperometric measurement was performed at an applied potential of -150 mV versus Ag/AgCl with a scan rate of 100 mV in the presence of hydroquinone as electron mediator and 0.1M phosphate buffer solution of pH 6.5. The variables influencing the performance of sensor including the amount of substrate, mediator concentration and electrolyte pH were optimized. The determination of sulfide can be achieved in a linear range of 1.09-16.3 μM with a detection limit of 0.3 μM. Developed sensor showed quicker response to sulfide compared to the previous developed sulfide biosensors. Common anions and cations in environmental water did not interfere with sulfide detection by the developed biosensor. Cyanide interference on the enzyme inhibition caused 43.25% error in the calibration assay which is less than the amounts reported by previous studies. Because of high sensitivity and the low-cost of SPE, this inhibition biosensor can be successfully used for analysis of environmental water samples.  相似文献   

15.
A model of a reactor-type biosensor based on the Rhodococcus erythropolis HL PM-1 was developed for amperometric detection of 2,4-dinitrophenol (2,4-DNP). The effects of the matrix material (agar and calcium alginate gels, ceramic support, and cellulose powder) on the biosensor signal concentration dependence, detection time, and biosensor stability were studied. In the case of bacterial cells immobilized on cellulose powder, the lower limit of 2,4-DNP detection was 20 M and the time of single analysis, the biosensor recovery included, was 30–50 min. In the continuous detection mode, the biosensor response was maintained at a stable level without biosensor inactivation for ten days. The biosensor can be used as an element of a complex analytical system for detecting nitroaromatic compounds in samples.  相似文献   

16.
The composite film based on Nafion and hydrophilic room temperature ionic liquid (RTIL) 1-butyl-3-methyl-imidazolium chloride ([bmim]Cl) was used as an immobilization matrix to entrap myoglobin (Mb). The study of ionic liquid (IL)-Mb interaction by ultraviolet-visible (UV-vis) spectroscopy showed that Mb retains its native conformation in the presence of IL. The immobilized Mb displayed a pair of well-defined cyclic voltammetric peaks with a formal potential (Eo) of −0.35 V in a 0.1 M phosphate buffer solution (PBS) of pH 7.0. The immobilized Mb exhibited excellent electrocatalytic response to the reduction of hydrogen peroxide, based on which a mediator-free amperometric biosensor for hydrogen peroxide was designed. The linear range for the determination of hydrogen peroxide was from 1.0 to 180 μM with a detection limit of 0.14 μM at a signal/noise ratio of 3. The apparent Michaelis constant () for the electrocatalytic reaction was 22.6 μM. The stability, repeatability, and selectivity of the sensor were evaluated. The proposed biosensor has a lower detection limit than many other IL-heme protein-based biosensors and is free from common interference in hydrogen peroxide biosensors.  相似文献   

17.
In this study, an acetylcholinesterase (AChE) biosensor with superior accuracy and sensitivity was successfully developed based on interdigitated array microelectrodes (IAMs). IAMs have a series of parallel microband electrodes with alternating microbands connected together. Chitosan was used as the enzyme immobilization material, and AChE was used as the model enzyme for carbaryl detection to fabricate AChE biosensor. Electrochemical impedance spectroscopy was used in conjunction with the fabricated biosensor to detect pesticide residues. Based on the inhibition of pesticides on the AChE activity, using carbaryl as model compounds, the biosensor exhibited a wide range, low detection limit, and high stability. Moreover, the biosensor can also be used as a new promising tool for pesticide residue analysis.  相似文献   

18.
A water-soluble biocompatible aziridine-based biosensor with pendant anthracene units was synthesized by radicalar polymerization of N-substituted aziridines in supercritical carbon dioxide. The binding ability of the sensor towards a series of metal ions was examined by comparing the fluorescence intensities of the solutions before and after the addition of 100 equivalents of a solution of the metal ion chloride salt. A fast, simple and highly optical sensitive dual behavior, "off-on" and "on-off" response, was observed after the biosensor was exposed to the metal cations in aqueous solution. Zinc presented the highest fluorescence enhancement (turn-on) and copper presented the highest fluorescence quenching (turn-off). The response time was found to be instantaneous and the detection limit was achieved even in the presence of excess metal cation competitors. By using immunofluorescence microscopy it was also shown that oligoaziridine acts as an "on-off" probe through highly sensitive (detection limit of 1.6nM), selective and reversible binding to copper anions under physiologic conditions using living Human Fibroblast cells. The stoichiometry for the reaction of the biosensor with Cu(2+) was determined by a Job plot and indicates the formation of an oligoaziridine-Cu(2+) 1:2 adduct.  相似文献   

19.
Comparative effects of partial root-zone irrigation (PRI) and deficit irrigation (DI) on xylem pH, ABA, and ionic concentrations of tomato (Lycopersicon esculentum L.) plants were investigated in two split-root pot experiments. Results showed that PRI plants had similar or significantly higher xylem pH, which was increased by 0.2 units relative to DI plants. Nitrate and total ionic concentrations (cations+anions), and the proportion of cations influenced xylem pH such that xylem pH increases as nitrate and total ionic concentrations decrease, and the proportion of cations increases. In most cases, the xylem ABA concentration was similar for PRI and DI plants, and a clear association between increases in xylem pH with increasing xylem ABA concentration was only found when the soil water content was relatively low. The concentrations of anions, cations, and the sum of anions and cations in PRI were higher than in the DI treatment when soil water content was relatively high in the wetted soil compartment. However, when water content in both soil compartments of the PRI pots were very low before the next irrigation, the acquisition of nutrients by roots was reduced, resulting in lower concentrations of anions and cations in the PRI than in the DI treatment. It is therefore essential that the soil water content in the wet zone should be maintained relatively high while that in the drying soil zone should not be very low, both conditions are crucial to maintain high soil and plant water status while sustaining ABA signalling of the plants.  相似文献   

20.
The lyophilized biomass of White rot fungi (Phanerochaete chrysosporium ME446) was immobilized in gelatine using glutaraldehyde crosslinking agent on a Pt working electrode. The fungal cells retained their laccase activity under entrapped state. The immobilized cells were used as a source of laccase to develop amperometric epinephrine biosensor. The catalytic action of the laccase in the biosensor released an epinephrinequinone as a result of redox activity, thereby causing an increase in the current. The optimal working conditions of the biosensor were carried out at pH 4.5 (50 mM acetate buffer containing 100 mM K(3)Fe(CN)(6)), and 20°C. The sensor response was linear over a range of 5-100 μM epinephrine. The detection limit of the biosensor was found to be 1.04 μM. In the optimization and characterization studies of the microbial biosensor some parameters such as effect of fungi and gelatine amount, percentage of glutaraldehyde on the biosensor response and substrate specificity were carried out. In the application studies of the biosensor, sensitive determination of epinephrine in pharmaceutical ampules was investigated.  相似文献   