首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
为了得到制备抗原芯片所需的高纯度重组抗原蛋白,需要建立一套适合于多种重组抗原表达和纯化的技术路线.采用了亲和层析结合制备胶电泳的方法,对16种用于构建蛋白质芯片的食管癌相关抗原基因进行了克隆重组并在大肠杆菌中进行了表达.对高表达的重组蛋白首先制备包涵体,然后采用Ni-Sepharose亲和层析得到初步纯化的蛋白质,最后使用SDS-PAGE制备胶电泳作进一步纯化.经过透析复性后,用于制备蛋白质芯片.采用亲和层析纯化重组蛋白,得率为71% ,纯度约为70%;在SDS-PAGE制备胶进一步纯化后,得率为32%,纯度为95%,经过透析和复性后,最终得率为21%,纯度为95%.得到的重组蛋白RPS4在ELISA检测中可以和血清中识别RPS4 的自身抗体起反应,并且,采用精纯抗原制备的蛋白质芯片,在检测抗原与抗体这一对反应中也具有较高的敏感性和特异性,适合大规模血清抗体的检测.研究表明,采用亲和层析结合制备凝胶电泳纯化抗原蛋白,是一条简便快捷,适合需要量不大,但对纯度要求比较高的蛋白质芯片制备的技术路线.  相似文献   

2.
High-throughput screening for interactions of peptides with a variety of antibody targets could greatly facilitate proteomic analysis for epitope mapping, enzyme profiling, drug discovery and biomarker identification. Peptide microarrays are suited for such undertaking because of their high-throughput capability. However, existing peptide microarrays lack the sensitivity needed for detecting low abundance proteins or low affinity peptide-protein interactions. This work presents a new peptide microarray platform constructed on nanostructured plasmonic gold substrates capable of metal enhanced NIR fluorescence enhancement (NIR-FE) by hundreds of folds for screening peptide-antibody interactions with ultrahigh sensitivity. Further, an integrated histone peptide and whole antigen array is developed on the same plasmonic gold chip for profiling human antibodies in the sera of systemic lupus erythematosus (SLE) patients, revealing that collectively a panel of biomarkers against unmodified and post-translationally modified histone peptides and several whole antigens allow more accurate differentiation of SLE patients from healthy individuals than profiling biomarkers against peptides or whole antigens alone.  相似文献   

3.
We developed a practical strategy for serum protein profiling using antibody microarrays and applied the method to the identification of potential biomarkers in prostate cancer serum. Protein abundances from 33 prostate cancer and 20 control serum samples were compared to abundances from a common reference pool using a two-color fluorescence assay. Robotically spotted microarrays containing 184 unique antibodies were prepared on two different substrates: polyacrylamide based hydrogels on glass and poly-1-lysine coated glass with a photoreactive cross-linking layer. The hydrogel substrate yielded an average six-fold higher signal-to-noise ratio than the other substrate, and detection of protein binding was possible from a greater number of antibodies using the hydrogels. A statistical filter based on the correlation of data from "reverse-labeled" experiment sets accurately predicted the agreement between the microarray measurements and enzyme-linked immunosorbent assay measurements, showing that this parameter can serve to screen for antibodies that are functional on microarrays. Having defined a set of reliable microarray measurements, we identified five proteins (von Willebrand Factor, immunoglobulinM, Alpha1-antichymotrypsin, Villin and immunoglobulinG) that had significantly different levels between the prostate cancer samples and the controls. These developments enable the immediate use of high-density antibody and protein microarrays in biomarker discovery studies.  相似文献   

4.
The release of proteins from tumors triggers an immune response in cancer patients. These tumor antigens arise from several mechanisms including tumor-specific alterations in protein expression, mutation, folding, degradation, or intracellular localization. Responses to most tumor antigens are rarely observed in healthy individuals, making the response itself a biomarker that betrays the presence of underlying cancer. Antibody immune responses show promise as clinical biomarkers because antibodies have long half-lives in serum, are easy to measure, and are stable in blood samples. However, our understanding of the specificity and the impact of the immune response in early stages of cancer is limited. The immune response to cancer, whether endogenous or driven by vaccines, involves highly specific T lymphocytes (which target tumor-derived peptides bound to self-MHC proteins) and B lymphocytes (which generate antibodies to tumor-derived proteins). T cell target antigens have been identified either by expression cloning from tumor cDNA libraries, or by prediction based on patterns of antigen expression ("reverse immunology"). B cell targets have been similarly identified using the antibodies in patient sera to screen cDNA libraries derived from tumor cell lines. This review focuses on the application of recent advances in proteomics for the identification of tumor antigens. These advances are opening the door for targeted vaccine development, and for using immune response signatures as biomarkers for cancer diagnosis and monitoring.  相似文献   

5.
To identify potential biomarkers of lung cancer (LC), profiling of proteins in sera obtained from healthy and LC patients was determined using an antibody microarray. Based on our previous study on mRNA expression profiles between patients with LC and healthy persons, 19 proteins of interest were selected as targets for fabrication of an antibody microarray. Antibody to each protein and five nonspecific control antibodies were spotted onto a hydrogel‐coated glass slide and used for profiling of proteins in sera of LC patients in a two‐color fluorescence assay. Forty‐eight human sera samples were analyzed, and expression profiling of proteins were represented by the internally normalized ratio method. Six proteins were distinctly down‐regulated in sera of LC patients; this observation was validated by Wilcoxon test, false discovery rate, and Western blotting. Blind test of other 32 human sera using the antibody microarray followed by hierarchical clustering analysis revealed an approximate sensitivity of 88%, specificity of 80%, and an accuracy of 84%, respectively, in classifying the sera, which supports the potential of the six identified proteins as biomarkers for the prognosis of lung cancer.  相似文献   

6.
Simian Virus 40, experimentally assayed in vitro in different animal and human cells and in vivo in rodents, was classified as a small DNA tumor virus. In previous studies, many groups identified Simian Virus 40 sequences in healthy individuals and cancer patients using PCR techniques, whereas others failed to detect the viral sequences in human specimens. These conflicting results prompted us to develop a novel indirect ELISA with synthetic peptides, mimicking Simian Virus 40 capsid viral protein antigens, named mimotopes. This immunologic assay allowed us to investigate the presence of serum antibodies against Simian Virus 40 and to verify whether Simian Virus 40 is circulating in humans. In this investigation two mimotopes from Simian Virus 40 large T antigen, the viral replication protein and oncoprotein, were employed to analyze for specific reactions to human sera antibodies. This indirect ELISA with synthetic peptides from Simian Virus 40 large T antigen was used to assay a new collection of serum samples from healthy subjects. This novel assay revealed that serum antibodies against Simian Virus 40 large T antigen mimotopes are detectable, at low titer, in healthy subjects aged from 18–65 years old. The overall prevalence of reactivity with the two Simian Virus 40 large T antigen peptides was 20%. This new ELISA with two mimotopes of the early viral regions is able to detect in a specific manner Simian Virus 40 large T antigen-antibody responses.  相似文献   

7.
8.
Prostate-specific antigen (PSA) is an important marker for the diagnosis and management of prostate cancer. Free PSA has been shown to be more extensively cleaved in sera from benign prostatic hyperplasia patients than in sera from prostate cancer patients. Moreover, the presence of enzymatically activatable PSA was characterized previously in sera from patients with prostate cancer by the use of the specific anti-free PSA monoclonal antibody (mAb) 5D3D11. As an attempt to obtain ligands for the specific recognition of different PSA forms including active PSA, phage-displayed linear and cyclic peptide libraries were screened with PSA coated directly into microplate wells or presented by two different anti-total PSA mAbs. Four different phage clones were selected for their ability to recognize PSA and the inserted peptides were produced as synthetic peptides. These peptides were found to capture and to detect specifically free PSA, even in complex biological media such as sera or tumour cell culture supernatants. Alanine scanning of peptide sequences showed the involvement of aromatic and hydrophobic residues in the interaction of the peptides with PSA whereas Spotscan analysis of overlapping peptides covering the PSA sequence identified a peptide binding to the kallikrein loop at residues 82-87, suggesting that the peptides could recognize a non-clipped form of PSA. Moreover, the PSA-specific peptides enhance the enzymatic activity of PSA immobilized into microplate wells whereas the capture of PSA by the peptides inhibited totally its enzymatic activity while the peptide binding to PSA had no effect in solution. These PSA-specific peptides could be potential tools for the recognition of PSA forms more specifically associated to prostate cancer.  相似文献   

9.
A new capture test utilizing conjugated peptides has been developed for the detection of antibodies elicited against HIV-1. Human sera diluted 1:1000 were incubated in ELISA plates precoated with protein G. The captured IgG were allowed to react with three synthetic peptides corresponding to the gp41 sequence (591-611) YLKDQQLLGIWGCSGKLICTT, the gp120 sequence (314-329) IRIQRGPGRAFVTIGK and the p27 sequence (182-198) EWRFDSRLAFHHVAREL. The peptides were used in the form of N-hydroxysuccinimido-biotin ovalbumin conjugates. Peroxidase-labelled streptavidin was used to detect antigen-antibody complexes. The sensitivity and specificity of detection of antibodies were analyzed with 40 HIV positive sera, 10 seroconverting sera and 21 normal human sera (NHS). The results were compared with a commercial indirect ELISA in which a single conjugated gp41 peptide was used as antigenic probe. This indirect ELISA recognized 100% of the HIV positive and the seroconverting sera. The new capture test using the gp41 conjugated peptide also recognized 100% of the HIV positive sera but was more specific since it gave no false positive results whereas the indirect test did. The gp120 and p27 conjugated peptides detected 35/40 (87.5%) and 31/40 (77.5%) of HIV positive sera respectively and also detected 9/10 (90%) and 10/10 (100%) of the seroconverting sera respectively, without any false positive results (0/21). The proposed new capture test is a very sensitive and specific assay for detecting HIV antibodies.  相似文献   

10.
B13, one of the immunodominant antigens of Trypanosoma cruzi, is composed of repeats of a 12-amino-acid motif. Using synthetic peptides, the sequence FGQAAAGDK was previously shown to contain the B13 immunodominant epitope recognized by chagasic patients sera. To investigate the effects of neighboring sequences in the immunodominance, we tested serum recognition of two B13 sequences fused to LamB. GDKPSPFGQAAA-LamB and FGQAAAGDKPSP-LamB were recognized, respectively, by 15% and 80% of 80 sera reactive to B13 antigen. Recognition of FGQAAAGDKPSP-LamB was inhibited by AAAGDK-containing synthetic peptides. FGQAAAGDKPSP-LamB competed with a B13 recombinant protein containing 16.6 repeats for binding to chagasic antibodies. These results strengthen previous conclusions on the immunodominant epitope of B13 and provide a comparison of two methods for epitope mapping.  相似文献   

11.
Abstract A new capture test utilizing conjugated peptides has been developed for the detection of antibodies elicited against HIV-1. Human sera diluted 1:1000 were incubated in ELISA plates precoated with protein G. The captured IgG were allowed to react with three synthetic peptides corresponding to the gp41 sequence (591–611) YLKDQQLLGIWGCSGKLICTT, the gp120 sequence (314–329) IRIQRGPGRAFVTIGK and the p27 sequence (182–198) EWRFDSRLAFHHVAREL. The peptides were used in the form of N -hydroxysuccinimido-biotin ovalbumin conjugates. Peroxidase-labelled streptavidin was used to detect antigen-antibody complexes. The sensitivity and specificity of detection of antibodies were analyzed with 40 HIV positive sera, 10 seroconverting sera and 21 normal human sera (NHS). The results were compared with a commercial indirect ELISA in which a single conjugated gp41 peptide was used as antigenic probe. This indirect ELISA recognized 100% of the HIV positive and the seroconverting sera. The new capture test using the gp41 conjugated peptide also recognized 100% of the HIV positive sera but was more specific since it gave no false positive results whereas the indirect test did. The gp120 and p27 conjugated peptides detected 35/40 (87.5%) and 31/40 (77.5%) of HIV positive sera respectively and also detected 9/10 (90%) and 10/10 (100%) of the seroconverting sera respectively, without any false positive results (0/21). The proposed new capture test is a very sensitive and specific assay for detecting HIV antibodies.  相似文献   

12.
Carbohydrate post-translational modifications on proteins are important determinants of protein function in both normal and disease biology. We have developed a method to allow the efficient, multiplexed study of glycans on individual proteins from complex mixtures, using antibody microarray capture of multiple proteins followed by detection with lectins or glycan-binding antibodies. Chemical derivatization of the glycans on the spotted antibodies prevented lectin binding to those glycans. Multiple lectins could be used as detection probes, each targeting different glycan groups, to build up lectin binding profiles of captured proteins. By profiling both protein and glycan variation in multiple samples using parallel sandwich and glycan-detection assays, we found cancer-associated glycan alteration on the proteins MUC1 and CEA in the serum of pancreatic cancer patients. Antibody arrays for glycan detection are highly effective for profiling variation in specific glycans on multiple proteins and should be useful in diverse areas of glycobiology research.  相似文献   

13.
Wang Y 《Proteomics》2004,4(1):20-26
The availability of a large number of biological materials such as cDNA, antibodies, recombinant proteins, and tissues has promoted the development of microarray technologies that make use of these materials in high-throughput screening assays. However, because microarray technologies have been less successful in examining proteins than DNA and mRNA, there is a need for improved protein microarray systems. To address this need, we developed an antibody microarray-based immunostaining method that can analyze the properties of a large number of proteins simultaneously. In this method, antibodies are arrayed and immobilized on a solid support and cells bearing antigens of interest are attached to a second support. Apposition of the two supports allows the antibodies to dissociate from the array support and bind to the cellular antigens. After separation of the supports, antigen-bound antibodies can be detected by standard secondary antibody techniques. These "dissociable" antibody arrays were used to detect both the expression and subcellular localization of a large number of specific proteins in various cultured cell types.  相似文献   

14.
15.
We constructed miniaturized autoantigen arrays to perform large-scale multiplex characterization of autoantibody responses directed against structurally diverse autoantigens, using submicroliter quantities of clinical samples. Autoantigen microarrays were produced by attaching hundreds of proteins, peptides and other biomolecules to the surface of derivatized glass slides using a robotic arrayer. Arrays were incubated with patient serum, and spectrally resolvable fluorescent labels were used to detect autoantibody binding to specific autoantigens on the array. We describe and characterize arrays containing the major autoantigens in eight distinct human autoimmune diseases, including systemic lupus erythematosus and rheumatoid arthritis. This represents the first report of application of such technology to multiple human disease sera, and will enable validated detection of antibodies recognizing autoantigens including proteins, peptides, enzyme complexes, ribonucleoprotein complexes, DNA and post-translationally modified antigens. Autoantigen microarrays represent a powerful tool to study the specificity and pathogenesis of autoantibody responses, and to identify and define relevant autoantigens in human autoimmune diseases.  相似文献   

16.
We describe a novel approach for high-throughput analysis of the immune response in cancer patients using phage-based microarray technology. The recombinant phages used for fabricating phage arrays were initially selected via the use of random peptide phage libraries and breast cancer patient serum antibodies. The peptides displayed by the phages retained their ability to be recognized by serum antibodies after immobilization. The recombinant phage microarrays were screened against either breast cancer or healthy donor serum antibodies. A model-based statistical method is proposed to estimate significant differences in serum antibody reactivity between patients and normals. A significant tumor effect was found with most of the selected phage-displayed peptides, suggesting that recombinant phage microarrays can serve as a tool in monitoring humoral responses towards phage-displayed peptides.  相似文献   

17.

Introduction

Autoantibodies directed against citrullinated proteins/peptides (ACPAs) are highly specific and predictive for the development of rheumatoid arthritis (RA). Different subgroups of RA patients, which have different prognoses and may require different treatments, are characterized by different autoantibody profiles. The objective of this study was to develop a microarray for the detection of multiple RA-associated autoantibodies, initially focusing on responses against citrullinated epitopes on candidate autoantigens in RA.

Methods

The microarray is based on Phadia''s ImmunoCAP ISAC system, with which reactivity to more than 100 antigens can be analyzed simultaneously, by using minute serum volumes (< 10 μl). Twelve citrullinated peptides, and the corresponding native arginine-containing control peptides, were immobilized in an arrayed fashion onto a chemically modified glass slide, allowing a three-dimensional layer with high binding capacity. The assay was optimized concerning serum dilution and glass surface, whereas each individual antigen was optimized concerning coupling chemistry, antigen concentration, and selection of spotting buffer. The performance of each peptide in the ImmunoCAP ISAC system was compared with the performance in enzyme-linked immunosorbent assays (ELISAs). Serum from 927 RA patients and 461 healthy controls from a matched case-control study were applied onto reaction sites on glass slides, followed by fluorescent-labeled anti-human immunoglobulin G (IgG) antibody. Fluorescence intensities were detected with a laser scanner, and the results analyzed by using image-analysis software.

Results

Strong correlations between the ImmunoCAP ISAC system and ELISA results were found for individual citrullinated peptides (Spearman ρ typically between 0.75 and 0.90). Reactivity of RA sera with the peptides was seen mainly in the anticyclic citrullinated peptide 2 (CCP2)-positive subset, but some additional reactivity with single citrullinated peptides was seen in the anti-CCP2-negative subset. Adjusting for reactivity against arginine-containing control peptides did not uniformly change the diagnostic performance for antibodies against the individual citrullinated peptides.

Conclusions

The multiplexed array, for detection of autoantibodies against multiple citrullinated epitopes on candidate RA autoantigens, will be of benefit in studies of RA pathogenesis, diagnosis, and potentially as a guide to individualized treatment.  相似文献   

18.
To identify malaria antigens for vaccine development, we selected alpha-helical coiled coil domains of proteins predicted to be present in the parasite erythrocytic stage. The corresponding synthetic peptides are expected to mimic structurally "native" epitopes. Indeed the 95 chemically synthesized peptides were all specifically recognized by human immune sera, though at various prevalence. Peptide specific antibodies were obtained both by affinity-purification from malaria immune sera and by immunization of mice. These antibodies did not show significant cross reactions, i.e., they were specific for the original peptide, reacted with native parasite proteins in infected erythrocytes and several were active in inhibiting in vitro parasite growth. Circular dichroism studies indicated that the selected peptides assumed partial or high alpha-helical content. Thus, we demonstrate that the bioinformatics/chemical synthesis approach described here can lead to the rapid identification of molecules which target biologically active antibodies, thus identifying suitable vaccine candidates. This strategy can be, in principle, extended to vaccine discovery in a wide range of other pathogens.  相似文献   

19.
In a search for synthetic peptide antigens fit to detect anti-HIV antibodies, a set of algorithms were used to predict the probable antigenic determinants of gag, pol, env and nef proteins of HIV-1 and HIV-2. Over forty peptides were synthesized by the solid-phase method. The reactivity of the peptide antigens was evaluated in ELISA on panels of HIV-1/2-positive sera. Application of the synthetic peptides for the early HIV diagnostics was examined.  相似文献   

20.
We present here the results from MS peptide profiling experiments of prostate carcinoma patients and controls with a specific focus on protease activity‐related protein fragments. After purification with surface‐active magnetic beads, MALDI‐TOF profiling experiments were performed on tryptic digests of serum samples of prostate cancer patients with metastases (n=27) and controls (n=30). This resulted in the reproducible detection of eight differentially expressed peptides, which were then identified by nanoLC‐MALDI‐TOF/TOF and confirmed by MALDI‐FTMS exact mass measurements. All differentially expressed peptides are derived from two homologous parts of human serum albumin; two of the eight peptides were tryptic and six were nontryptic. The presence of the nontryptic fragments indicates that a proteolysis process occurs which is not mediated by trypsin. Since the nontryptic fragments were found at significantly higher levels in control samples compared with metastases samples, it is proposed that a specific proteolytic inhibition process is in effect in the serum of prostate cancer patients. Experiments using synthetic peptides showed that this proteolytic activity occurs ex vivo and is sequence specific. Importantly, the observed prostate carcinoma‐related inhibition of the proteolysis was reproduced ex vivo using synthetic peptides.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号