首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Silica-encapsulated magnetic nanoparticles (MNPs) were prepared via microemulsion method. The products were characterized by high resolution transmission electron microscopy (HRTEM) and energy-dispersive X-ray spectrum (EDS). MNPs with no observed cytotoxic activity against human lung carcinoma cell and brine shrimp lethality were used as suitable support for glucose oxidase (GOD) immobilization. Binding of GOD onto the support was confirmed by the FTIR spectra. The amount of immobilized GODs was 95 mg/g. Storage stability study showed that the immobilized GOD retained 98% of its initial activity after 45 days and 90% of the activity was also remained after 12 repeated uses. Considerable enhancements in thermal stabilities were observed for the immobilized GOD at elevated temperatures up to 80°C and the activity of immobilized enzyme was less sensitive to pH changes in solution.  相似文献   

2.
The co-immobilization of glucose oxidase (GOD) and hexokinase/glucose-6-phosphate dehydrogenase (HEX) in the silica hybrid sol-gel film for development of amperometric biosensors was investigated. The silica hybrid film fabricated by hydrolysis of the mixture of tetraethyl orthosilicate and 3-(trimethoxysiyl)propyl methacrylate possessed a three-dimension vesicle structure and good uniformity and conformability, and was ready for enzyme immobilization. The electrochemical and spectroscopic measurements showed that the silica hybrid sol-gel provided excellent matrice for the enzyme immobilization and that the immobilized enzyme retained its bioactivity effectively. The immobilized GOD could catalyze the oxidation of glucose, which could be used to determine glucose at +1.0 V without help of any mediator. The competition between GOD and HEX for the substrate glucose involving ATP as a co-substrate led to a decrease of the glucose response, which allowed us to develop an ATP sensor with a good stability. The fabricated silica hybrid sol-gel matrice offered a stage for further study of immobilization and electrochemistry of proteins.  相似文献   

3.
Yang Z  Ren Y  Zhang Y  Li J  Li H  Hu XH  Xu Q 《Biosensors & bioelectronics》2011,26(11):4337-4341
A novel biosensor is developed based on immobilization of proteins on nanoflake-like SnS? modified glass carbon electrode (GCE). With glucose oxidase (GOD) as a model, direct electrochemistry of the GOD/nanoflake-like SnS? is studied. The prepared SnS? has large surface area and can offer favorable microenvironment for facilitating the electron transfer between protein and electrode surface. The properties of GOD/SnS? are characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), UV-vis spectroscopy, Fourier transform infrared spectroscopy (FTIR) and cyclic voltammetry (CV), respectively. The immobilized enzyme on nanoflake-like SnS? retains its native structure and bioactivity and exhibits a surface-controlled, reversible two-proton and two-electron transfer reaction with the apparent electron transfer rate constant (k(s)) of 3.68 s?1. The proposed biosensor shows fast amperometric response (8s) to glucose with a wide linear range from 2.5 × 10?? M to 1.1 × 10?3 M, a low detection limit of 1.0 × 10?? M at signal-to-noise of 3 and good sensitivity (7.6 ± 0.5 mA M?1 cm?2). The resulting biosensor has acceptable operational stability, good reproducibility and excellent selectivity and can be successfully applied in the reagentless glucose sensing at -0.45 V. It should be worthwhile noting that it opens a new avenue for fabricating excellent electrochemical biosensor.  相似文献   

4.
One-step construction of Pt nanoparticles-chitosan composite film (PtNPs-CS) was firstly proposed as a novel immobilization matrix for the enzymes to fabricate glucose biosensor. This novel interface embedded in situ PtNPs in CS hydrogel was developed by one-step electrochemical deposition in solution containing CS and chloroplatinic acid (H(2)PtCl(6)). Several techniques, including scanning electron microscopy (SEM), cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and chronoamperometry were employed to characterize the assembly process and performance of the biosensor. Under the optimized experimental conditions, the resulting biosensor exhibited excellent linear behavior in the concentration range from 1.2 μM to 4.0 mM for the quantitative analysis of glucose with a limit of detection of 0.4 μM at a signal-to-noise ratio of 3. The apparent Michaelis-Menten constant (K(M)(app)) was evaluated to be 2.4 mM, showing good affinity. The proposed biosensor offered good amperometric responses to glucose due to the nanostructured sensing film provided plenty of active sites for the immobilization of glucose oxidase (GOD).  相似文献   

5.
Liu S  Tian J  Wang L  Luo Y  Lu W  Sun X 《Biosensors & bioelectronics》2011,26(11):4491-4496
Graphene platelet-glucose oxidase (GP-GOD) nanostructures have been prepared through self-assembly of GOD and chitosan (CS) functionalized GPs by electrostatic attraction in aqueous solution. The stable aqueous dispersion of GPs was prepared by chemical reduction of graphene oxide with the use of CS as a reducing and stabilizing agent. UV-vis spectroscopy, X-ray diffraction, transmission electron microscopy, scanning electron microscopy and X-ray photoelectron spectroscopy were used to characterize the resulting GPs and GP-GOD nanostructures. Furthermore, a glucose biosensor was constructed by deposition of the resultant GP-GOD on the surface of glassy carbon electrode. It was found that the resulting biosensor exhibits good response to glucose. The linear detection range is estimated to be from 2 to 22 mM (r=0.9987), and the detection limit is estimated to be 20 μM at a signal-to-noise ratio of 3.  相似文献   

6.
Calcium carbonate nanoparticles (nano-CaCO3) may be a promising material for enzyme immobilization owing to their high biocompatibility, large specific surface area and their aggregation properties. This attractive material was exploited for the mild immobilization of glucose oxidase (GOD) in order to develop glucose amperometric biosensor. The GOD/nano-CaCO3-based sensor exhibited a marked improvement in thermal stability compared to other glucose biosensors based on inorganic host matrixes. Amperometric detection of glucose was evaluated by holding the modified electrode at 0.60 V (versus SCE) in order to oxidize the hydrogen peroxide generated by the enzymatic reaction. The biosensor exhibited a rapid response (6s), a low detection limit (0.1 microM), a wide linear range of 0.001-12 mM, a high sensitivity (58.1 mAcm-2M-1), as well as a good operational and storage stability. In addition, optimization of the biosensor construction, the effects of the applied potential as well as common interfering compounds on the amperometric response of the sensor were investigated and discussed herein.  相似文献   

7.
Genetically engineered periplasmic glucose receptors as biomolecular recognition elements on gold nanoparticles (AuNPs) have allowed our laboratory to develop a sensitive and reagentless electrochemical glucose biosensor. The receptors were immobilized on AuNPs by a direct sulfur-gold bond through a cysteine residue that was engineered in position 1 on the protein sequence. The study of the attachment of genetically engineered and wild-type proteins binding to the AuNPs was first carried out in colloidal gold solutions. These constructs were studied and characterized by UV-Vis spectroscopy, transmission electron microscopy, particle size distribution, and zeta potential. We show that the genetically engineered cysteine is important for the immobilization of the protein to the AuNPs. Fabrication of the novel electrochemical biosensor for the detection of glucose used these receptor-coated AuNPs. The sensor showed selective detection of glucose in the micromolar concentration range, with a detection limit of 0.18 microM.  相似文献   

8.
An electrochemical glucose sensor has been integrated, together with a pH sensor, on a flexible polyimide substrate for in vivo applications. The glucose sensor is based on the measurement of H2O2 produced by the membrane-entrapped enzyme glucose oxidase (GOD). To minimize electrochemical interference, an electrode configuration was designed to perform differential measurements. The solid-state pH sensor employs a PVC-based neutral carrier membrane. The enzymes GOD and catalase were immobilized into two layers of photolithographically patterned hydrogels. The intended use of this device is the short-term monitoring of glucose and pH in intensive care units and operating theatres, especially for neurosurgical applications. The developed immobilization technique can also be used to create integrated multi-sensor chips for clinical analysers. The glucose and pH sensor exhibited excellent performance during tests in buffer solutions, serum and whole blood.  相似文献   

9.
Nickel oxide microfibers (NiO-MFs) were directly immobilized onto the surface of fluorine tin oxide (FTO) electrode by electrospinning and calcination without using any immobilization matrix for nonenzymatic glucose sensor. Morphology and structure of NiO-MFs were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), and X-ray diffraction pattern (XRD). The electrochemical and electrocatalytic performances of the NiO-MFs modified electrodes prepared at different calcination temperatures ranging from 300 to 500°C were evaluated by cyclic voltammetry (CV). The CV results have demonstrated that NiO-MFs modified electrode prepared at 300°C displayed distinct increase in electrocatalytic activity toward the oxidation of glucose, which is explored to develop an amperometric nonenzymatic glucose sensor. The NiO-MFs prepared at 300°C based amperometric nonenzymatic glucose sensor has ultrasensitive current (1785.41 μA mM(-1) cm(-2)) response and low detection limit of 3.3×10(-8) M (signal/noise ratio (S/N)=3), which are among the best values reported in literature. Additionally, excellent selectivity and stability have also been obtained.  相似文献   

10.
A surface modification technique was developed for the functionalization of polypyrrole (PPY) film with glucose oxidase (GOD) and viologen moieties. The PPY film was first graft copolymerized with acrylic acid (AAc) and GOD was then covalently immobilized through the amide linkage formation between the amino groups of the GOD and the carboxyl groups of the grafted AAc polymer chains in the presence of a water-soluble carbodiimide. Viologen moieties could also be attached to the PPY film via graft-copolymerization of vinyl benzyl chloride with the PPY film surface followed by reaction with 4,4'-bipyridine and alpha,alpha'-dichloro-p-xylene. X-ray photoelectron spectroscopy (XPS) was used to characterize the PPY films after each surface modification step. Increasing the AAc graft concentration would allow a greater amount of GOD to be immobilized but this would decrease the electrical conductivity of the PPY film. The activity of the immobilized GOD was compared with that of free GOD and the kinetic effects were also studied. The immobilized GOD was found to be less sensitive to temperature deactivation as compared to the free GOD. The results showed that the covalent immobilization technique offers advantages over the technique involving the entrapment of GOD in PPY films during electropolymerization. The presence of viologen in the vicinity of the immobilized GOD also enabled the GOD-catalyzed oxidation of glucose to proceed under UV irradiation in the absence of O(2).  相似文献   

11.
The surface functionalization of an electrically conductive polypyrrole film (PPY) with a viologen, (N-(2-carboxyl-ethyl)-N'-(4-vinyl-benzyl)-4,4'-bipyridinium dichloride, or CVV) for the covalent immobilization of glucose oxidase (GOD) has been carried out. The viologen was first synthesized and graft polymerized on PPY film. It then served as an anchor via its carboxyl groups for the covalent immobilization of GOD. The surface composition of the as-functionalized substrates was characterized by X-ray photoelectron spectroscopy (XPS). The effects of the CVV monomer concentration on the CVV-graft polymer concentration and the amount of GOD immobilized on the surface were investigated. The activity of the immobilized GOD was compared with that of free GOD and the kinetic effects were also obtained. The cyclic voltammetric (CV) response of the GOD-functionalized PPY substrates was studied in a phosphate buffer solution under an argon atmosphere. The CV results support the mechanism in which CVV acts as a mediator to transfer electron between the electrode and enzyme, and hence regenerating the enzyme in the enzymatic reaction with glucose. High sensitivity and linear response of the enzyme electrode was observed with glucose concentration ranging from 0 to 20 mM.  相似文献   

12.
A bienzymatic glucose biosensor was proposed for selective and sensitive detection of glucose. This mediatorless biosensor was made by simultaneous immobilization of glucose oxidase (GOD) and horseradish peroxidase (HRP) in an electropolymerized pyrrole (PPy) film on a single-wall carbon nanotubes (SWNT) coated electrode. The amperometric detection of glucose was assayed by potentiostating the bienzymatic electrode at -0.1 versus Ag/AgCl to reduce the enzymatically produced H(2)O(2) with minimal interference from the coexisting electroactive compounds. The single-wall carbon nanotubes, sandwiched between the enzyme loading polypyrrole (PPy) layer and the conducting substrate (gold electrode), could efficiently promote the direct electron transfer of HRP. Operational characteristics of the bienzymatic sensor, in terms of linear range, detection limit, sensitivity, selectivity and stability, were presented in detail.  相似文献   

13.
In this study, a new chemiluminescence (CL) flow-through biosensor for glucose was developed by immobilizing glucose oxidase (GOD) and horseradish peroxidase (HRP) on the eggshell membrane with glutaraldehyde as a cross-linker. The CL detection involved enzymatic oxidation of glucose to D-gluconic acid and hydrogen peroxide (H2O2) and then H2O2 oxidizing luminol to produce CL emission in the presence of HRP. The immobilization condition (e.g., immobilization time, GOD/HRP ratio, glutaraldehyde concentration) was studied in detail. It showed good storage stability at 4 degrees C over a 5-month period. The proposed biosensor exhibited short response time, high sensitivity, easy operation, and simple sensor assembly, and the proposed biosensor was successfully applied to the determination of glucose in human serum.  相似文献   

14.
A highly sensitive molecular-imprinted polymer sensor (MIP sensor) for ultratrace oxytetracycline (OTC) determination was prepared based on the competition reaction between template molecule OTC and glucose oxidase (GOD)-labeled OTC (GOD-OTC). Sensitivity improved dramatically due to the detection of a huge amount of enzyme catalytic production, which was inversely proportional to template molecule concentration. The MIP sensor was characterized by alternating current impedance spectroscopy and cyclic voltammetry, and its voltammetric behavior was also verified. Experimental conditions including isolation, incubation, and competition were optimized. OTC can be determined at concentrations between 0 and 4.0×10(-7) mol/L with a detection limit of 3.30×10(-10) mol/L by the differential pulse voltammetry technique. The MIP sensor showed high sensitivity, selectivity, reproducibility, and good recovery in sample determination.  相似文献   

15.
A new amperometric biosensor, based on adsorption of glucose oxidase (GOD) at the platinum nanoparticle-modified carbon nanotube (CNT) electrode, is presented in this article. CNTs were grown directly on the graphite substrate. The resulting GOD/Pt/CNT electrode was covered by a thin layer of Nafion to avoid the loss of GOD in determination and to improve the anti-interferent ability. The morphologies and electrochemical performance of the CNT, Pt/CNT, and Nafion/GOD/Pt/CNT electrodes have been investigated by scanning electron microscopy, cyclic voltammetry, and amperometric methods. The excellent electrocatalytic activity and special three-dimensional structure of the enzyme electrode result in good characteristics such as a large determination range (0.1-13.5mM), a short response time (within 5s), a large current density (1.176 mA cm(-2)), and high sensitivity (91mA M(-1)cm(-2)) and stability (73.5% remains after 22 days). In addition, effects of pH value, applied potential, electrode construction, and electroactive interferents on the amperometric response of the sensor were investigated and discussed. The reproducibility and applicability to whole blood analysis of the enzyme electrode were also evaluated.  相似文献   

16.
A sensitive staining procedure for glucose oxidase (GOD) as marker in immunohistology is described. The cytochemical procedure involves a two-step enzyme method in which GOD and horseradish peroxidase (HRP) are coimmobilized onto the same cellular sites by immunological bridging or by the principle of avidin-biotin interaction. In this coupled enzyme technique, H2O2 generated during GOD reaction is the substrate for HRP and is utilized for the oxidation of chromogens such as 3,3'-diaminobenzidine or 3-amino-9-ethylcarbazole. Due to the immobilization of the capture enzyme HRP in close proximity to the marker enzyme (GOD), more intense and specific staining is produced than can be obtained with soluble HRP as coupling enzyme in the substrate medium. Indirect antibody labelled and antibody bridge techniques including the avidin (streptavidin)-biotin principle have proven the usefulness of this GOD labelling procedure for antigen localization in paraffin sections. Antigens such as IgA in tonsil, alpha-fetoprotein in liver and tissue polypeptide antigen in mammary gland served as models. The immobilized two-step enzyme procedures have the same order of sensitivity and specificity as comparable immunoperoxidase methods. The coupled GOD-HRP principle can be superior to conventional immunoperoxidase labelling for the localization of biomolecules in tissue preparations rich in endogenous peroxidase activities.  相似文献   

17.
Glucose oxidase (GOD) and catalase (CAT) were simultaneously co-immobilized onto magnesium silicate (Florisil®) by covalent coupling. Glucose was added in immobilization mixture and hydrogen peroxide, which is the substrate of CAT, was produced in coupling mixture during immobilization time. Therefore, co-immobilization of GOD and CAT was carried out in the presence of both their substrates: glucose and hydrogen peroxide, respectively. The effect of glucose concentration in immobilization mixture on activities of GOD and CAT of co-immobilized samples were investigated. Maximum GOD and CAT activities were determined for samples co-immobilized in the presence of 15 and 20 mM glucose, respectively. Co-immobilization of GOD and CAT in the presence of their substrates highly improved the activity and reusability of both enzymes.  相似文献   

18.
Lu W  Luo Y  Chang G  Sun X 《Biosensors & bioelectronics》2011,26(12):4791-4797
In this paper, we report on the first preparation of well-defined SiO(2)-coated graphene oxide (GO) nanosheets (SiO(2)/GO) without prior GO functionalization by combining sonication with sol-gel technique. The functional SiO(2)/GO nanocomposites (F-SiO(2)/GO) obtained by surface functionalization with NH(2) group were subsequently employed as a support for loading Ag nanoparticles (AgNPs) to synthesize AgNP-decorated F-SiO(2)/GO nanosheets (AgNP/F-SiO(2)/GO) by two different routes: (1) direct adsorption of preformed, negatively charged AgNPs; (2) in situ chemical reduction of silver salts. The morphologies of these nanocomposites were characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM). It is found that the resultant AgNP/F-SiO(2)/GO exhibits remarkable catalytic performance for H(2)O(2) reduction. This H(2)O(2) sensor has a fast amperometric response time of less than 2s. The linear range is estimated to be from 1×10(-4) M to 0.26 M (r=0.998) and the detection limit is estimated to be 4 × 10(-6) M at a signal-to-noise ratio of 3, respectively. We also fabricated a glucose biosensor by immobilizing glucose oxidase (GOD) into AgNP/F-SiO(2)/GO nanocomposite-modified glassy carbon electrode (GCE) for glucose detection. Our study demonstrates that the resultant glucose biosensor can be used for the glucose detection in human blood serum.  相似文献   

19.
The direct electrochemistry of glucose oxidase (GOD) adsorbed on a CdS nanoparticles modified pyrolytic graphite electrode was investigated, where the enzyme demonstrated significantly enhanced electron-transfer reactivity. GOD adsorbed on CdS nanoparticles maintained its bioactivity and structure, and could electro-catalyze the reduction of dissolved oxygen, which resulted in a great increase of the reduction peak current. Upon the addition of glucose, the reduction peak current decreased, which could be used for glucose detection. Performance and characteristics of the fabricated glucose biosensor were assessed with respect to detection limit, sensitivity, storage stability and interference exclusion. The results showed that the fabricated biosensor was sensitive and stable in detecting glucose, indicating that CdS nanoparticle was a good candidate material for the immobilization of enzyme in glucose biosensor construction.  相似文献   

20.
High activity of glucose oxidase (GOD) enzyme (immobilized in porous silica particles) is desirable for a better glucose biosensor. In this work, effect of pore diameter of two porous hosts on enzyme immobilization, activity and glucose sensing was compared. The hosts were amine functionalized: (i) microporous silica (NH2-MS) and (ii) mesoporous silica (NH2-SBA-15). Based on whether the dimension of GOD is either larger or smaller than the pore diameter, GOD was immobilized on either external or internal surface of NH2-MS and NH2-SBA-15, with loadings of 512.5 and 634 mg/g, respectively. However, GOD in NH2-SBA-15 gave a higher normalized absolute activity (NAA), which led to an amperometric sensor with a larger linear range of 0.4–13.0 mM glucose. In comparison, GOD in NH2-MS had a lower NAA and a smaller linear range of 0.4–3.1 mM. In fact, the present GOD-NH2-SBA-15 electrode based sensor was better than other MS and SBA-15 based electrodes reported in literature. Thus, achieving only a high GOD loading (as in NH2-MS) does not necessarily give a good sensor performance. Instead, a host with a relatively larger pore than enzyme, together with optimized electrode composition ensures the sensor to be functional in both hyper- and hypoglycemic range.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号