首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BackgroundVoltage mapping is critical to define substrate during ablation. In ventricular tachycardia, abnormal potentials may be targets. However, wavefront of activation could impact local signal characteristics. This may be particularly true when comparing sinus rhythm versus paced rhythms. We sought to determine how activation wavefront impacts electrogram characteristics.MethodsPatients with ischemic cardiomyopathy, ventricular tachycardia, and without fascicular or bundle branch block were included. Point by point mapping was done and at each point, one was obtained during an atrial paced rhythm and one during a right ventricular paced rhythm. Signals were adjudicated after ablation to define late potentials, fractionated potentials, and quantify local voltage. Areas of abnormal voltage (defined as <1.5 mV) were also determined.Results9 patients were included (age 61.3 ± 9.2 years, 56% male, mean LVEF 34.9 ± 8.6%). LV endocardium was mapped with an average 375 ± 53 points/rhythm. Late potentials were more frequent during right ventricular pacing (51 ± 21 versus 32 ± 15, p < 0.01) while overall scar area was higher during atrial pacing (22 ± 11% vs 13 ± 7%, p < 0.05). In 1/9 patients, abnormal potentials were seen during a right ventricular paced rhythm that were not apparent in an atrial paced rhythm, ablation of which resulted in non-inducibility.ConclusionRhythm in which mapping is performed has an impact on electrogram characteristics. Whether one rhythm is preferable to map in remains to be determined. However, it is possible defining local signals during normal conduction as well as variable paced rhythms may impart a greater likelihood of elucidating arrhythmogenic substrate.  相似文献   

2.
Ventricular tachycardia (VT) occurring late after myocardial infarction is often due to reentry circuit in the peri-infarct zone. The circuit is usually located in the sub-endocardium, though subepicardial substrates are known. Activation mapping during VT to identify target regions for ablation can be difficult if VT is non inducible or poorly tolerated. In the latter, a substrate based approach of mapping during sinus rhythm in conjunction with pace mapping helps to define the reentry circuit and select target sites for ablation in majority of patients with hemodynamically unstable VT. Percutaneous epicardial catheter ablation has been attempted as an approach where ablation by a conventional endocardial access has been unsuccessful. We report a case of post myocardial infarction scar VT which could be successfully ablated with a substrate based approach from the epicardial aspect.  相似文献   

3.
Introduction– Local impedance (LI) guided ablation as a method of judging lesion effectiveness for cavotricuspid isthmus dependent atrial flutter (CTI-AFL), and ultra-high density (UHD) mapping when breakthrough occurred across an ablation line has not previously been assessed.MethodsThis retrospective observational study evaluated patients undergoing CTI-AFL ablation using conventional, contact force (CF) and LI guided strategies. Ablation metrics were collected, and in the LI cohort, the use of UHD mapping for breakthrough evaluated.Results30 patients were included, 10 per group. Mean total ablation time was significantly shorter with LI (3.2 ± 1.3min) vs conventional (5.6 ± 2.7min) and CF (5.7 ± 2.0min, p = 0.0042). Time from start of ablation to CTI block was numerically shorter with LI (14.2 ± 8.0min) vs conventional and CF (19.7 ± 14.1 and 22.5 ± 19.1min, p = 0.4408). Mean lesion duration was significantly shorter with LI, but there were no differences in the number of lesions required to achieve block, procedural success, complication rates or recurrence. 15/30 patients did not achieve block following first-pass ablation. UHD mapping rapidly identified breakthrough in the five LI patients, including epicardial-endocardial breakthrough (EEB).Conclusion– The use of LI during ablation for real-time lesion assessment was as efficacious as the conventional and CF methods. UHD mapping rapidly identified breakthrough, including EEB.  相似文献   

4.
BackgroundElectro-anatomic 3D mapping systems enable the fluoroscopy (FL) exposure to be reduced. In right-heart supraventricular tachycardia (SVT) procedures, FL could potentially be avoided. Our aim was to discuss some steps focusing on safety.Methods and resultsThe patient cohort comprised 70 consecutive SVT patients who underwent electrophysiologic (EP) catheterization. FL was routinely avoided in all cases (54.2% males, age 57.2 ± 13.3 years): 51 ablations and 19 EP study procedures. The Carto®3 (Biosense Webster) mapping system was used in 17/70 cases (24.3%), and the EnSite Precision? (Abbott) system in the remaining 53/70 (75.7%). The mean procedure time was 94.1 ± 33.2 min; no FL was used. No major complications occurred. Acute procedural success was achieved in all 51 patients who underwent ablation. Over 3-month follow-up, arrhythmia recurred in 1 patient. There were no significant differences in procedural times between the two mapping systems, except for the time dedicated to the full geometry creation, which was longer for the EnSite Precision? system: 10 min (8.5–15 IQR) vs 8 min (5–10 IQR) for the Carto® system (p < 0.001) mainly due to the sub-diaphragmatic navigation. The following procedural steps were considered critical in order to safely avoid FL use: “loop” advancing of catheters, the use of a fixed intracardiac reference, His signal landmark centered maps and the careful acquisition of sub-diaphragmatic extracardiac geometry.ConclusionsA routine zero X-ray approach by means of electro-anatomic 3D mapping systems is safe and effective in right-atrium procedures. Some ad-hoc discussed procedural steps may enhance safety.  相似文献   

5.
BackgroundCatheter ablation provides curative treatment for tachyarrhythmias. Fluoroscopy, the method used for this, presents several risks. The electroanatomical mapping (MEA) presents a three-dimensional image without using X-rays, and may be adjunct to fluoroscopy.ObjectivesWe evaluated the possibility of performing catheter ablation with the exclusive use of electroanatomical mapping (MEA), dispensing with fluoroscopy. We compared the total time of procedure and success rates against the technique using fluoroscopy (RX) with emission of X-rays.MethodsRandomized, unicentric, uni-blind study of patients referred for tachyarrhythmia ablation.ResultsTwelve patients were randomized to the XR group and 11 to the EAM group. The mean age was 48.5 (±12.6) vs 46.3 (±16.6) (P = ns). Success occurred in 11 patients (91.7%) in the RX group and 9 (81.8%) in the MEA group (P = 0.46). The procedure time in minutes was higher in the MEA group than in the RX group (79-47-125min vs 49-30-100min; P = 0.006). The mean fluoroscopy time was 11 ± 9 min versus zero (RX vs MEA: P < 0.001). The mean radiofrequency applications were lower in the RX group against the MEA group (6 ± 3.5 × 13.2 ± 18.2 p < 0.019). There were no complications.ConclusionMEA opened new therapeutic possibilities for patients with arrhythmias, reducing the risk of radiation. In this study, it was possible to demonstrate that it is feasible to perform ablation only with the use of MEA, with similar success with fluoroscopy, at the expense of a longer procedure time.  相似文献   

6.
IntroductionThe AcQMap High Resolution Imaging and Mapping System was recently introduced. This system provides 3D maps of electrical activation across an ultrasound-acquired atrial surface.MethodsWe evaluated the feasibility and the acute and short-term efficacy and safety of this novel system for ablation of persistent atrial fibrillation (AF) and atypical atrial flutter.ResultsA total of 21 consecutive patients (age (mean ± standard deviation) 62 ± 8 years, 23% female) underwent catheter ablation with the use of the AcQMap System. Fourteen patients (67%) were treated for persistent AF and 7 patients (33%) for atypical atrial flutter. Eighteen patients (86%) had undergone at least one prior ablation procedure. Acute success, defined as sinus rhythm without the ability to provoke the clinical arrhythmia, was achieved in 17 patients (81%). At 12 months, 4 patients treated for persistent AF (29%) and 4 patients treated for atypical flutter (57%) remained in sinus rhythm. Complications included hemiparesis, for which intra-arterial thrombolysis was given with subsequent good clinical outcome (n = 1), and complete atrioventricular block, for which a permanent pacemaker was implanted (n = 2). No major complications attributable to the mapping system occurred.ConclusionThe AcQMap System is able to provide fast, high-resolution activation maps of persistent AF and atypical atrial flutter. Despite a high acute success rate, the recurrence rate of persistent AF was relatively high. This may be due to the selection of the patients with therapy-resistant arrhythmias and limited experience in the optimal use of this mapping system that is still under development.Supplementary InformationThe online version of this article (10.1007/s12471-021-01636-w) contains supplementary material, which is available to authorized users.  相似文献   

7.
Radiofrequency ablation has an important role in the management of post infarction ventricular tachycardia. The mapping and ablation of ventricular tachycardia (VT) is complex and technically challenging. In the era of implantable cardioverter defibrillators, the role of radiofrequency ablation is most commonly reserved as an adjunctive treatment for patients with frequent, symptomatic episodes of ventricular tachycardia. In this setting the procedure has a success rate of around 70-80% and a low complication rate. With improved ability to predict recurrent VT and improvements in mapping and ablation techniques and technologies, the role of radiofrequency ablation should expand further.  相似文献   

8.
黄浩  孙毅勇 《生物信息学》2019,17(2):102-110
为了进一步探究房颤患者心内不同位置信号的主导频率(Dominant frequency,简称DF)的关联性,本文对传统的Botteron’s算法进行了改进。当信号中含有较大幅值的室波时,该改进算法可以更好地提取DF。利用该算法对20例临床房颤消融手术的冠状静脉窦(Coronary sinus,简称CS)导管、环肺静脉(Pulmonary veins,简称PV)导管采集的信号进行了观察和分析。在大部分病例中都能观察到其CS和PV的信号里都存在相同频率的DF;同时发现CS的DF并不仅仅来自当前标测的PV。实验结果表明:房颤的潜在病灶区域不仅仅具有较高频率的DF,且其DF的频率应当与心房采集的DF频率存在对应关系。这或许可以为寻找房颤的潜在病灶区域提供参考。  相似文献   

9.
In recent years, the nonmedical management of atrial fibrillation (AF) has rapidly evolved, with more options available to address the arrhythmia. Determining the successful return of sinus rhythm and the medical management after ablation requires the selection of the correct diagnostic method. In May 2007, the Heart Rhythm Society in conjunction with the Society for Thoracic Surgeons, the European Heart Rhythm Association, and the European Cardiac Arrhythmia Society identified the need for programs to adopt a consistent method of follow-up and monitoring. Choosing the right monitor for the determination of the success, postsurgical ablation that meets the Heart Rhythm Society guidelines for monitoring especially for asymptomatic patients is imperative. Therefore, we reviewed the current devices available to assist practitioners in determining which monitor best meets their needs The criteria selected to perform the review include (1) ease of use for patients (compliance), (2) ability of the monitor to perform internal analysis, (3) the monitor has >24 hours of storage capability, and (4) external support. Our selection criteria revealed six cardiac rhythm monitors currently available for use. This review compared the different arrhythmia monitors from an established monitoring program perspective to assist practitioners in choosing a monitor that meets their practice needs for determining the return to sinus rhythm postsurgical ablation.  相似文献   

10.
Three-dimensional (3D) mapping and navigation systems have been widely used for the ablation of atrial fibrillation and ventricular tachycardia, but the applicability of these systems for the ablation of supraventricular tachycardia (SVT) due to right-sided accessory pathways (RAPs) remains unknown. The goal of this prospective randomized study was to compare the safety, efficiency, and efficacy of nonfluoroscopic and conventional fluoroscopic mapping techniques in guiding catheter ablation of SVT due to RAPs. Of the 393 consecutive patients with SVT who were randomized to receive either conventional fluoroscopic or Ensite NavX mapping-guided ablation, 64 patients with RAPs were included for analysis. Endpoints for ablation were no evidence of RAP conduction and no inducible atrioventricular reentrant tachycardia (AVRT). The 3D group showed fewer ablation pulses and a shorter total ablation time compared to the conventional group, although the acute procedural success did not differ significantly between the two groups. Total procedure time, electrophysiological study time, total fluoroscopy time, and cumulative radiation doses were also significantly reduced in the 3D group. Patients in the conventional group with a right atrium diameter (RAD) ≥ 47 mm required a longer fluoroscopy time. There was no significant difference in the recurrence rates between the two groups over a follow-up period of 3 to 29 months. There were no permanent complications. The 3D mapping system may be a preferred alternative for patients with AVRT due to RAPs, especially for patients with a large RAD (≥ 47 mm).  相似文献   

11.
Contact force (CF) is one of the major determinants for sufficient lesion formation. CF-guided procedures are associated with enhanced lesion formation and procedural success. We report our initial experience in epicardial ventricular tachycardia (VT) ablation with a force-sensing catheter using a new approach with an angioplasty balloon. Two patients with arrhythmogenic right ventricular cardiomyopathy who underwent prior unsuccessful endocardial ablation were treated with epicardial VT ablation. CF data were used to titrate force, power and ablation time.  相似文献   

12.
Pulmonary vein isolation (PVI) using radiofrequency current (RFC) ablation is a potentially curative treatment option for patients with atrial fibrillation (AF). The shortcomings of the RFC technology (technically challenging, long procedure times, complications) steadily kindle the interest in new energy sources and catheter designs. High intensity focused ultrasound (HIFU) has the ability to precisely focus ultrasound waves in a defined area with a high energy density. HIFU balloon catheters (BC) positioned at the PV ostia appear to be an ideal tool to transmit the ablation energy in a circumferential manner to the PV ostia and may therefore bear substantial advantage over conventional ablation catheters in PVI procedures. In clinical trials the HIFU BC has shown promising success rates similar to RFC catheter ablation for PVI in patients with AF. However, procedure times are still long and serious complications have been observed. Therefore, it may be a valuable alternative to the conventional techniques in selected patients but further clinical trials have to be initiated.  相似文献   

13.
利用分子标记定位水稻野败型核质互作雄性不育恢复基因   总被引:22,自引:2,他引:22  
李平  周开达 《遗传学报》1996,23(5):357-362
以籼稻恢复系圭630与粳型广亲和品种02428的F1代花药培养,获得81个双单倍体(DH),构建了有233个RFLP标记的分子图谱。用籼稻野败型不育系珍汕97A测定各DH系的恢复性,并将恢复性作为数量性状进行QTL的区间作图分析,鉴别出8个基因座位,其中有2个基因座位,Rfi-3和尾Rfi-4,单个QTL的基因贡献值分别是49.6%和35.4%,对育性恢复起主要作用,定为主效基因座位,位于第三和四染色体上,其它6个基因座位对育性恢复亦有一定的影响。表明野败型雄性不育恢复性是受主效基因和微效基因共同控制的性状。  相似文献   

14.
Percutaneous epicardial mapping and ablation is an emerging method to treat ventricular tachycardias (VT), premature ventricular complexes (PVC), and accessory pathways. The use of a remote magnetic navigation system (MNS) could enhance precision and maintain safety. This multiple case history demonstrates the feasibility and safety of the MNS-guided epicardial approach in mapping and ablation of ischaemic VT, outflow tract PVCs, and a left-sided accessory pathway. All patients had previously undergone endocardial mapping for the same arrhythmia. MNS could present an advantage from more precise navigation for mapping and maintaining catheter stability during energy application.  相似文献   

15.
BackgroundThe soil transmitted helminths are a group of parasitic worms responsible for extensive morbidity in many of the world’s most economically depressed locations. With growing emphasis on disease mapping and eradication, the availability of accurate and cost-effective diagnostic measures is of paramount importance to global control and elimination efforts. While real-time PCR-based molecular detection assays have shown great promise, to date, these assays have utilized sub-optimal targets. By performing next-generation sequencing-based repeat analyses, we have identified high copy-number, non-coding DNA sequences from a series of soil transmitted pathogens. We have used these repetitive DNA elements as targets in the development of novel, multi-parallel, PCR-based diagnostic assays.Conclusions/SignificanceThe utilization of next-generation sequencing-based repeat DNA analysis methodologies for the identification of molecular diagnostic targets has the ability to improve assay species-specificity and limits of detection. By exploiting such high copy-number repeat sequences, the assays described here will facilitate soil transmitted helminth diagnostic efforts. We recommend similar analyses when designing PCR-based diagnostic tests for the detection of other eukaryotic pathogens.  相似文献   

16.
Magnetic assisted navigation is a new innovation that may prove useful in catheter ablation of cardiac arrhythmias and cardiac resynchronization therapy. The ability to steer extremely floppy catheters and guidewires may allow for these to be positioned safely in previously inaccessible areas of the heart. The integration of other new technology, such as image integration and electroanatomic mapping systems, should advance our abilities further. Although studies have shown the technology to be feasible, with the advantage to the physician of decreased radiation exposure, studies need to be performed to show additional benefit over standard techniques.  相似文献   

17.
Radio frequency (RF) catheter ablation of accessory pathways represents an interventional method in modern cardiology that has become the first-line treatment for patients with symptomatic WPW-syndrome. The aim of this study was to analyze: (1) the learning curve for the ablation procedure; (2) procedural parameters and success; and (3) personal assessment of the treatment by the patients. Learning curve analysis included 195 consecutive patients, who underwent ablation between 1991 and 1996. The follow-up survey included 65 consecutive patients. The analysis of the procedural parameters showed significant improvement after 100 cases, implying a completion of the learning curve at this point. Long-term follow-up showed a high success rate for all pathways (95.4%). All procedure parameters indicated significantly higher degree of difficulty for right free-wall and septal pathways, with lowest long-term success rate for right-sided pathways (78.6%). Personal assessment survey showed high acceptance of the treatment; the procedure was described as a significant improvement of overall quality-of-life by 92.3% of patients. The results of this study confirm the catheter ablation of accessory pathways--in particular after completion of the learning curve--as a low-risk and highly efficient treatment for symptomatic WPW-syndrome, with a high degree of patient-related acceptance.  相似文献   

18.
Focal point-by-point radiofrequency catheter ablation has shown considerable success in the treatment of paroxysmal atrial fibrillation. However, it is not without limitations. Recent clinical and preclinical studies have demonstrated that cryothermal ablation using a balloon catheter (Artic Front©, Medtronic CryoCath LP) provides an effective alternative strategy to treating atrial fibrillation. The objective of this article is to review efficacy and safety data surrounding cryoballoon ablation for paroxysmal and persistent atrial fibrillation. In addition, a practical step-by-step approach to cryoballoon ablation is presented, while highlighting relevant literature regarding: 1) the rationale for adjunctive imaging, 2) selection of an appropriate cryoballoon size, 3) predictors of efficacy, 4) advanced trouble-shooting techniques, and 5) strategies to reduce procedural complications, such as phrenic nerve palsy.  相似文献   

19.
This paper discusses the transition toward a circular economy ecosystem (CEE) for plastics by assessing and mapping existing ecosystems and coordinating efforts among ecosystem actors. The PlastiCity ecosystem is used as a case study. The study employs ecosystem analysis and mapping to identify the new activities and actors needed to transition toward a CEE. These include local and eco-friendly transportation, plastic recycling knowledge management, and upgrading the existing recycling infrastructure. The findings emphasize the significance of the joint orchestration of ecosystem actors facilitated by an ecosystem coordinator and knowledge team to achieve a CEE. It presents a tangible and feasible approach to achieving a local plastic CEE. The policymakers are encouraged to support collaborative orchestration efforts among ecosystem actors and establish knowledge management practices that facilitate ecosystem transitions.  相似文献   

20.
DNA/GUI (DNA Graphical User Interface) is an interactive software system for rapid and efficient analysis of images of the types used in genome mapping, such as autoradiograms and electrophoretic gels. Images are digitized using a commercially available charge-coupled-device (CCD) camera system and analyzed on a graphics workstation using a menu-driven user interface. DNA/GUI features automatic lane and band detection, simultaneous display of multiple images and a unique spatial-normalization algorithm. Images and their associated data are archived and easily available for later recall. Preliminary results indicate that DNA/GUI is a useful tool in the analysis and comparison of images used in a variety of applications such as genetic-linkage analysis and DNA restriction mapping. The interactive display software is based on the X Window System and is therefore readily portable to a variety of graphics workstations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号