首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A sensitive and selective liquid chromatography tandem mass spectrometry method using negative electrospray ionisation (LC-ESI-MS/MS) was developed for the simultaneous determination of zearalenone (ZEN), deoxynivalenol (DON) and their metabolites α-zearalenol, β-zearalenol, zearalanone, α-zearalanol, β-zearalanol and de-epoxy-deoxynivalenol in pig serum. For method development, different sample preparation columns were tested for their suitability for extraction and clean up. Finally, preparation of serum samples was carried out using Oasis? HLB solid-phase extraction (SPE) columns. The analyte concentrations were determined by the use of isotopically labelled internal standards (IS). The method was in-house validated for all analytes. Calibration graphs (0.3–480 ng/ml) were prepared and high degree of linearity was achieved (r?≥?0.99). Results for method precision ranged between 2.7 and 21.5 % for inter-day and between 1.1 and 11.1 % for intra-day. The recoveries were in the range of 82–131 %. Limits of detection and quantification ranged 0.03–0.71 and 0.08–2.37 ng/ml, respectively. The method has been successfully used for quantitative determination of ZEN, DON and their metabolites in pig serum from a feeding trial with practically relevant ZEN and DON concentrations. This method is precise and reproducible and can be used as a multi-biomarker method to assess animal exposure to these mycotoxins and for diagnosis of intoxications.  相似文献   

2.
This paper describes a rapid, specific and sensitive method for the determination of 29 organophosphorus pesticides in blood and serum, involving a rapid solid-phase extraction procedure using Oasis HLB cartridges and gas chromatography coupled to mass-selective detection. The ionization was performed by electron Impact and acquisition in the single ion monitoring mode followed three specific ions per analyte. Extraction recoveries were satisfactory and ranged between 40 and 108% in blood and serum. Limits of detection ranged from 5 to 25 ng/ml and limits of quantitation (LOQs) ranged from 10 to 50 ng/ml, in blood and serum. An excellent linearity was observed from these LOQs up to 1000 ng/ml. Intra- and inter-assay precision and accuracy were satisfactory for most of the pesticides analyzed.  相似文献   

3.
Meher Parveen 《FEBS letters》2009,583(14):2377-69
To compare gene expression profiles in response to estrogen or 17β-estradiol (E2) and a mycotoxin, zearalenone (ZEA), and its analogues (collectively termed ZEA compounds), breast cancer MCF-7 cells were treated with 10 nM of E2 or ZEA compounds including ZEA, α-zearalenol, β-zearalenol, zearalanone, α-zearalanol and β-zearalanol. Expression profiles for 120 estrogen-responsive genes were subjected to cluster and statistical analyses using correlation coefficients or R-values. We found that all of the ZEA compounds stimulated the growth of MCF-7 cells, as much as E2, and showed similar expression profiles to that of E2 (R-values ranged from 0.82 to 0.96). The effect of ZEA compounds was likely mediated by estrogen-receptor-dependent Erk1/2-signaling. These results provide clues to understand the mechanism of their estrogen-like action.  相似文献   

4.
A rapid and reliable ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of zearalenone (ZEN), α-zearalenol (α-ZOL), β-zearalenol (β-ZOL), zearalanone (ZAN), α-zearalanol (α-ZAL) and β-zearalanol (β-ZAL) in traditional Chinese medicines (TCMs) was developed. The development of the method and investigations of the matrix influence were described in particular. After evaluation of the matrix effects of different TCMs, i.e., rhizomes and roots, seeds, flowers, grasses and leaves, by the post-extraction spiked method, a reliable sample clean-up method based on home-made clean-up cartridges, a suitable internal standard and the matrix calibration were combined using to minimize the matrix effects to ensure the accuracy of the method. The established method was further validated by determining the linearity (R(2)≥0.9990), sensitivity (limit of quantitation 0.11-0.99 ng mL(-1)), average recovery (86.6-113.5%) and precision (relative standard deviation ≤13.5%). It was shown to be a suitable method for simultaneous determination of ZEN, α-ZOL, β-ZOL, ZAN, α-ZAL and β-ZAL in different TCMs. Finally, the established method was successfully applied to the determination of the six mycotoxins in various TCMs and the results were presented to provide relevant insights to researchers in TCM analysis.  相似文献   

5.
A sensitive and specific high-performance liquid chromatographic (HPLC) method for the determination of cortisol in only 200 microliters of serum is described. Cortisol and two internal standards, 19-nortestosterone (IS1) and 6 alpha-methylprednisolone (IS2) are extracted with dichloromethane and analyzed on a C18 reversed-phase column eluted with a mobile phase of methanol:water at a flow rate of 0.75 ml/min. Ultraviolet absorption at 254 nm is used for detection and quantitation is performed by peak height ratio measurement. Using 200 microliters of serum, the lower limit of detection for cortisol is 10 ng/ml, the analytical recovery is 104 +/- 3.6% (n = 8), and the day-to-day precision was 1.69% at a level of 90 ng/ml (n = 16). Cortisol values obtained by this method were generally lower than those obtained by radioimmunoassay or by fluorometry. A serum pool was analyzed both by HPLC and by isotope dilution/mass spectrometry (ID/MS). A mean value of 90.1 ng/ml was obtained by HPLC (n = 16, CV = 1.7%), whereas ID/MS yielded a mean of 90.8 ng/ml (n = 28, CV = 0.4%). These results clearly demonstrate the high specificity and the accuracy of the HPLC procedure. The use of two internal standards not only compensates for losses during the sample manipulation but also prevents erroneous results in case of medication by either of these two products.  相似文献   

6.
Zearalenone-6′-carboxymethyloxime was synthesized, and its conjugates to albumins and gelatin were prepared. Polyclonal rabbit antibodies against the conjugate with bovine serum albumin were shown to be highly specific to zearalenone and to have a lower cross-reactivity toward its structural analogues (a-zearalenol, 28%; ß-zearalenol, 6%; zearalanone, 12%; and α-zearalanol, 5%). The sensitivity of enzyme immunoassay with immobilized gelatin-based conjugates for determination of zearalenone in solution was 1 ng/ml, and this allowed us to determine this substance in feed at a threshold concentration of 200 μg/kg.  相似文献   

7.
玉米赤霉烯酮(zeralenone,ZEN)具有雌激素活性,主要污染谷物和饲料,大量聚积可导致流产和死胎,给动物和人类健康带来严重威胁。本研究通过将ZEN偶联抗原ZEN-BSA包被于纳米磁珠(magnetic nanoparticles,MNPs),制备纳米磁珠-偶联抗原复合物(MNPs-BSA-ZEN),同时使用金颗粒(Au nanoparticles,AuNPs)和辣根过氧化物酶(horseradish peroxidase,HRP)双标记的ZEN单克隆抗体,建立新型酶联免疫检测方法(MNPs-HRP-AuNPsIC-ELISA)。检测下限(IC10)达到0.03ng/mL,检测区间(IC20–IC80)为0.05–0.89ng/mL,半数抑制率(IC50)为0.22ng/mL,与ZEN类似物(α-zearalanol、zearalanone、α-zearalenol、β-zearalenol和β-zearalanol)的交叉反应性依次为19.2%、11.7%、8.3%、1.2%和4.3%,与黄曲霉毒素B1、赭曲霉毒素A、伏马毒素B1、桔青霉素和展青霉毒素几乎不存在交叉反应。在玉米、面粉和大豆样本中的加标回收率可达81.6%–113.5%,与LC-MS/MS同时对天然样本中ZEN含量的检测结果表明,两种方法相关性良好。本研究建立的MNPs-HRP-AuNPs IC-ELISA具备快速和高灵敏的双重优势,也可为其他霉菌毒素精准检测技术的开发提供参考。  相似文献   

8.
A gas chromatographic–mass spectrometric method was developed for the determination of residues of clenbuterol in bovine urine. The method involves a simple cation-exchange clean-up and concentration of clenbuterol in the acidified urine, followed by ethyl acetate extraction. The analyte is determined as the di-trimethylsilyl derivative and quantitated against an internal standard of penbutolol. Using a 5-ml sample of urine, a detection limit of 0.07 ng/ml can be achieved with recoveries close to 100% for fortification levels of 0.2 and 1 ng/ml. By increasing the sample volume to 50 ml, a detection limit below 0.01 ng/ml was achievable with recovery averaging 70%. The coefficient of variation of the assay ranged from 15% at 0.01 ng/ml (50-ml sample) to 6% at 1 ng/ml (5-ml sample). It was demonstrated that the method can detect the presence of clenbuterol in bovine urine at sub-ppb (ng/ml) levels using low resolution GC–MS with electron impact (EI) ionization.  相似文献   

9.
Zhao M  Baker SD  Yan X  Zhao Y  Wright WW  Zirkin BR  Jarow JP 《Steroids》2004,69(11-12):721-726
A rapid, sensitive, and specific method using liquid chromatography tandem mass spectrometry (LC/MS/MS) has been developed for simultaneous determination of testosterone (T), dihydrotestosterone (DHT), estradiol (E2), and 5alpha-androstan-3alpha, -17beta-diol (3alpha-Diol) within human testicular fluid. Sample pretreatment involved a one-step extraction with diethyl ether. The analytes were separated on a Waters X-Terra C18 (150 mm x 2.1 mm i.d., 3.5 microm) analytical column with acetonitrile/water mobile phase (70:30, v/v) containing 0.1% formic acid using isocratic flow at 0.15 ml/min for 8 min. The column effluent was monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated over the range of 0.1-50 ng/ml for T, 0.02-1 ng/ml for DHT, 0.05-2 ng/ml for E2, and 0.2-10 ng/ml for 3alpha-Diol, with values for the coefficient of determination of >0.99. The overall extraction efficiency was greater than 86% for T, 75% for DHT, 66% for E2, and 60% for 3alpha-Diol. The values for within-day and between-day precision and accuracy were <15%. We measured each of the four steroids in testicular sample volumes of only 20 microl, obtained by percutaneous testicular aspiration. The mean intratesticular testosterone concentration found by LC/MS/MS, 572 +/- 102 ng/ml, was similar to that previously obtained by radioimmunoassay (RIA). The mean intratesticular estradiol concentration was 15.7 +/- 2.3 ng/ml, which also correlated well with RIA measurement. Both DHT and 3alpha-Diol were below the limits of detection by RIA, but could be measured accurately by LC/MS/MS. In conclusion, LC/MS/MS represents a sensitive and accurate means by which to measure four separate steroids within small volume samples of testicular fluid.  相似文献   

10.
An assay based on negative ion chemical ionization mass spectrometry has been developed to quantify retinoic acid in plasma or serum. The lower limit of detection is 75 pg (240 fmol); normal values of retinoic acid can be determined on as little as 40 microliters of human plasma. The plasma concentrations of total retinoic acid in 12 healthy male volunteers taking no medication or vitamin supplementation ranged from 2.8 to 6.6 ng/ml; the mean was 4.9 ng/ml. The assay can be manipulated to measure all-trans-retinoic acid alone; about 75% of retinoic acid in human plasma or rat serum is all-trans-retinoic acid. Both retinol and retinoic acid can be quantified on the same 0.1-ml sample; the concentration of retinoic acid in human plasma or rat serum is at least 150-fold less than that of retinol.  相似文献   

11.
A sensitive and rapid high-performance liquid chromatographic screening method is described for the determination of anabolic steroid trenbolone in bovine muscle and liver. Trenbolone was analyzed as α- and β-trenbolone. Samples were extracted with ethyl acetate and cleaned up on a silica solid-phase extraction (SPE) cartridge. Liver samples were cleaned up on a multifunctional SPE cartridge before using a silica SPE cartridge. Analysis of α- and β-trenbolone was performed by reversed-phase high-performance liquid chromatography (HPLC) with a fluorescence detector. The detection limits for this method were estimated to be 0.2 and 1.0 ng/g in bovine muscle and liver, respectively. The mean recoveries spiked in muscle at 2 ng/g and in liver at 10 ng/g were over 80%.  相似文献   

12.
A simple, sensitive and selective liquid chromatography coupled with electrospray ionization mass spectrometry (LC/ESI/MS) method for the determination of simvastatin (I) has been developed. After extraction by ethyl acetate, using lovastatin (II) as internal standard, solutes are separated on a C(18) column with a mobile phase consisting of methanol-water (9:1). Detection is performed on an atmospheric pressure ionization single quadruple mass spectrometer equipped with an ESI interface and operates in positive ionization mode. Simvastatin quantification was realized by computing peak area ratio (I/II) of the extracts analyzed in SIM mode (m/z: 441 and m/z: 427 for I and II, respectively) and comparing them with calibration curve (r=0.9997). Accuracy and precision for the assay were determined by calculating the intra-batch and inter-batch variation at three concentrations 0.1, 5.0, 10.0 ng/ml; the intra batch relative standard deviation (RSD) was less than 10% and ranged from 1.8 to 8.5%, respectively; the inter-batch RSD was less than 20% and ranged from 4.1 to 16.5%. The limit of detection was 0.05 ng/ml.  相似文献   

13.
An inexpensive enzyme immunoassay method was designed for the determination of thyroglobulin concentration in human blood serum. The range of concentrations of thyroglobulin which can be measured by the method is between 6 and 800 ng/ml. The sensitivity of the method is comparable to that of the commercial test kits. The values of thyroglobulin concentration obtained with the use of the described method are strongly correlated (r = 0.946) with those obtained by using the reference method (IRMA kit of Byk, Sweden). The intraassay coefficient of variation ranged from 5.5 to 10.2% and interassay coefficient of variation from 9.5 to 13.2% depending on the thyroglobulin concentration. The upper limit of blood serum thyroglobulin concentration in healthy subjects was 70 ng/ml. The results of thyroglobulin determination obtained with the described method are falsely lowered in the presence of antithyroglobulin antibodies; simultaneous determination of these antibodies is thus necessary in such a case. It seems that the described method may be used for monitoring the patients after surgical treatment of differentiated thyroid cancer aimed at early detection of metastases.  相似文献   

14.
A highly sensitive and specific method has been developed for the simultaneous measurement of free (unconjugated) or sulfate-conjugated forms of dehydroepiandrosterone (DHEA), 7alpha-hydroxy-DHEA (7alpha-OH-DHEA), 7beta-hydroxy-DHEA (7beta-OH-DHEA), and 7-oxo-DHEA (7-oxo-DHEA) in human serum. This method is based upon a stable isotope-dilution technique by gas chromatography-selected-ion monitoring mass spectrometry. Free steroids were extracted from serum with an organic solvent and the sulfate-conjugated steroids remained in aqueous phase. Free steroids were purified by solid-phase extraction, while sulfate-conjugated steroids were hydrolyzed by sulfatase and deconjugated steroids were purified by solid-phase extractions. The extracts were treated with O-methylhydroxylamine hydrochloride and were subsequently dimethylisopropylsilylated. The resulting methyloxime-dimethylisopropylsilyl (MO-DMIPS) ether derivatives were quantified by gas chromatography-selected-ion monitoring mass spectrometry in a high-resolution mode. The detection limits of MO-DMIPS ether derivatives of DHEA, 7alpha-OH-DHEA, 7beta-OH-DHEA and 7-oxo-DHEA were 1.0, 0.5, 0.5 and 2.0pg, respectively. Coefficients of variation between samples ranged from 10.6 to 22.9% for free 7-oxygenated DHEA to less than 10% for DHEA and sulfate-conjugated 7-oxygenated DHEA. The concentrations of these steroids were measured in 18 sera samples from healthy volunteers (9 males and 9 females; aged 23-78 years). Free DHEA, 7alpha-OH-DHEA, 7beta-OH-DHEA and 7-oxo-DHEA levels ranged between 0.21-3.55, 0.001-0.194, 0.003-0.481, and 0.000-0.077ng/ml, respectively, and the sulfate-conjugated steroid levels of these metabolites ranged between 253-4681, 0.082-3.001, 0.008-0.903, and 0.107-0.803ng/ml, respectively. The free DHEA-related steroid concentrations were much lower than those previously measured by RIA and low-resolution GC-MS. The present method made it possible to determine simultaneously serum DHEA-related steroid levels with sufficient sensitivity and accuracy.  相似文献   

15.
A simple, rapid, sensitive, and specific liquid chromatography-mass spectrometry (LC-MS) method was developed and validated for the quantification of amitraz and its metabolite in human serum. Both the compounds were extracted using monolithic silica spin columns with acetonitrile. The chromatographic separation was performed on a reverse-phase C(18) column with a mobile phase of 10 mM ammonium formate-acetonitrile. The protonated analyte was quantitated in positive ionization by mass spectrometry. The method was validated over the concentration range of 25-1000 ng/ml for amitraz and its metabolite in human serum. For both compounds, the limit of detection was 5 ng/ml. The method was applied to serum samples taken from an attempted suicide patient, and only small volumes of serum were required for the simultaneous determination of these compounds.  相似文献   

16.
A liquid chromatographic-tandem mass spectrometric (LC-MS-MS) method has been developed for the determination of trenbolone in bovine urine and serum. The aim was a control of the misuse of trenbolone in food-producing animals. The procedure involved, in both cases, a preliminary solid-phase clean-up followed by a liquid-liquid extraction for urine samples after a preliminary enzymatic hydrolysis. The extracts have been directly analysed by reversed-phase LC-MS-MS in selected reaction monitoring (SRM), acquiring two diagnostic product ions from the chosen precursor [M+H](+). The procedures were validated across the concentration range of 1-1500 ng/ml. The linearity, the inter- and intra-day accuracy and precision have been determined. The procedure was specific and the accuracy values were better than 20% at the limit of quantitation of spiked samples. The limit of quantification (LOQ) and the limit of detection (LOD) were, respectively, 1 ng/ml and 350 pg/ml for urine and serum. According to the draft, SANCO/1805/2000, we determined the decision limit CCalpha and the detection capability CCbeta. The recovery values for urine ranged from 87 to 128%, and for plasma the recovery was 70+/-4%. The procedure proved to be simple and suitable for routine and confirmatory purposes such as those developed for residue studies.  相似文献   

17.
A rapid and accurate determination of tetracycline antibiotics in human serum by reversed-phase high-performance liquid chromatography with fluorescence detection has been developed, based on protein precipitation in serum. Various reagents for precipitation were investigated, and 24% trichloroacetic acid in methanolic solution gave the maximum recovery (at least 94.3%) and interference-free chromatograms of different three tetracyclines. At a concentration of 0.5 μg/ml, the precision (relative standard deviation) ranged from 1.12 to 1.94%. In the range 0.04–10.0 μg/ml for oxytetracycline and chlorotetracycline and 0.01–10.0 μg/ml for tetracycline, linear responses were observed. The detection limits of this method were 10–35 ng/ml for all three antibiotics. The proposed method was applied to the determination of serum concentrations in subjects receiving tetracycline antibiotics.  相似文献   

18.
An HPLC procedure has been developed for tocopherol determination with coulometric detection in human serum samples. Eluent optimization and foreign peak identification (bilirubin) by mass spectrometry are described. An extraction procedure gave yields around 98% with 1.3% coefficient of variation, and the calibration ranged from 0.1 to 200 mg/l with a correlation coefficient of 0.999. The detection limit achieved for vitamin E was 60 pg (3 ng/ml).  相似文献   

19.
An automated HPLC method with column switching is described for the determination of quetiapine, clozapine, perazine, olanzapine and metabolites in blood serum. After clean-up on silica C8 material (20 microm particle size) drugs were separated on ODS Hypersil C18 material (5 microm; column size 250 mm x 4.6 mm i.d.) within 25 min and quantified by ultraviolet (UV) detection at 254 nm. The limit of quantification ranged between 10 and 50 ng/ml. At therapeutic concentrations of the drugs, the inter-assay reproducibility was below 10%. Analyses of drug concentrations in serum of 75-295 patients treated with therapeutic doses of the antipsychotic drugs revealed mean+/-S.D. steady state concentrations of 139+/-136 ng/ml for quetiapine, 328+/-195 ng/ml for clozapine, 48+/-27 ng/ml for olanzapine and 71+/-52 ng/ml for perazine. The method was thus suitable for routine therapeutic drug monitoring and may be extended to other drugs.  相似文献   

20.
A simple, sensitive and specific liquid chromatography coupled electrospray ionization mass spectrometric (LC/ESI/MS) method for the determination of 13-O-demethylated metabolite (MI), one of the major metabolites of tacrolimus has been developed. The assay uses 32-demethoxyrapamycin (IS) as the internal standard; ethyl acetate as extraction solvent; a Hypersil-Keystone Beta Basic-18 reversed-phase column; and a gradient mobile phase of consisting 0.1% formic acid in water and methanol-acetonitrile (3:49, v/v). Mass detection is performed on a single quadrupole mass spectrometer equipped with an electrospray ionization (ESI) interface and operated in a positive ionization mode. MI in the microsomal incubates was quantitated by computing the peak area ratio (MI/IS) analyzed in single ion monitoring (SIM) mode (m/z: 804 and m/z: 901 for MI and IS, respectively). Precision of the assay was determined by calculating the intra-run and inter-run variation at three concentrations (15, 25, 80 ng/ml); the intra run relative standard deviation (R.S.D.) was less than 10% and ranged from 5.0 to 8.3%; and the inter-run R.S.D. was less than 10% and ranged from 4.6 to 9.6%. The limits of detection was 2 ng/ml. This assay has been used to evaluate the effect of three human immunodeficiency virus (HIV) protease inhibitors on the metabolism of tacrolimus in human liver microsomes.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号