首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

One of the central physiological functions of the lungs is to transfer inhaled gases from the alveoli to pulmonary capillary blood. However, current measures of alveolar gas uptake provide only global information and thus lack the sensitivity and specificity needed to account for regional variations in gas exchange.

Methods and Principal Findings

Here we exploit the solubility, high magnetic resonance (MR) signal intensity, and large chemical shift of hyperpolarized (HP) 129Xe to probe the regional uptake of alveolar gases by directly imaging HP 129Xe dissolved in the gas exchange tissues and pulmonary capillary blood of human subjects. The resulting single breath-hold, three-dimensional MR images are optimized using millisecond repetition times and high flip angle radio-frequency pulses, because the dissolved HP 129Xe magnetization is rapidly replenished by diffusive exchange with alveolar 129Xe. The dissolved HP 129Xe MR images display significant, directional heterogeneity, with increased signal intensity observed from the gravity-dependent portions of the lungs.

Conclusions

The features observed in dissolved-phase 129Xe MR images are consistent with gravity-dependent lung deformation, which produces increased ventilation, reduced alveolar size (i.e., higher surface-to-volume ratios), higher tissue densities, and increased perfusion in the dependent portions of the lungs. Thus, these results suggest that dissolved HP 129Xe imaging reports on pulmonary function at a fundamental level.  相似文献   

2.

Background

Hyperpolarized (HP) 129Xe magnetic resonance imaging (MRI) permits high resolution, regional visualization of pulmonary ventilation. Additionally, its reasonably high solubility (>10%) and large chemical shift range (>200 ppm) in tissues allow HP 129Xe to serve as a regional probe of pulmonary perfusion and gas transport, when introduced directly into the vasculature. In earlier work, vascular delivery was accomplished in rats by first dissolving HP 129Xe in a biologically compatible carrier solution, injecting the solution into the vasculature, and then detecting HP 129Xe as it emerged into the alveolar airspaces. Although easily implemented, this approach was constrained by the tolerable injection volume and the duration of the HP 129Xe signal.

Methods and Principal Findings

Here, we overcome the volume and temporal constraints imposed by injection, by using hydrophobic, microporous, gas-exchange membranes to directly and continuously infuse 129Xe into the arterial blood of live rats with an extracorporeal (EC) circuit. The resulting gas-phase 129Xe signal is sufficient to generate diffusive gas exchange- and pulmonary perfusion-dependent, 3D MR images with a nominal resolution of 2×2×2 mm3. We also show that the 129Xe signal dynamics during EC infusion are well described by an analytical model that incorporates both mass transport into the blood and longitudinal relaxation.

Conclusions

Extracorporeal infusion of HP 129Xe enables rapid, 3D MR imaging of rat lungs and, when combined with ventilation imaging, will permit spatially resolved studies of the ventilation-perfusion ratio in small animals. Moreover, EC infusion should allow 129Xe to be delivered elsewhere in the body and make possible functional and molecular imaging approaches that are currently not feasible using inhaled HP 129Xe.  相似文献   

3.
Ex vivo rodent lung models are explored for physiological measurements of respiratory function with hyperpolarized (hp) 129Xe MRI. It is shown that excised lung models allow for simplification of the technical challenges involved and provide valuable physiological insights that are not feasible using in vivo MRI protocols. A custom designed breathing apparatus enables MR images of gas distribution on increasing ventilation volumes of actively inhaled hp 129Xe. Straightforward hp 129Xe MRI protocols provide residual lung volume (RV) data and permit for spatially resolved tracking of small hp 129Xe probe volumes during the inhalation cycle. Hp 129Xe MRI of lung function in the excised organ demonstrates the persistence of post mortem airway responsiveness to intravenous methacholine challenges. The presented methodology enables physiology of lung function in health and disease without additional regulatory approval requirements and reduces the technical and logistical challenges with hp gas MRI experiments. The post mortem lung functional data can augment histological measurements and should be of interest for drug development studies.  相似文献   

4.
《Biophysical journal》2022,121(23):4635-4643
Protein interiors contain void space that can bind small gas molecules. Determination of gas pathways and kinetics in proteins has been an intriguing and challenging task. Here, we combined computational methods and the hyperpolarized xenon-129 chemical exchange saturation transfer (hyper-CEST) NMR technique to investigate xenon (Xe) exchange kinetics in maltose-binding protein (MBP). A salt bridge ~9 Å from the Xe-binding site formed upon maltose binding and slowed the Xe exchange rate, leading to a hyper-CEST 129Xe signal from maltose-bound MBP. Xe dissociation occurred faster than dissociation of the salt bridge, as shown by 13C NMR spectroscopy and variable-B1 hyper-CEST experiments. “Xe flooding” molecular dynamics simulations identified a surface hydrophobic site, V23, that has good Xe binding affinity. Mutations at this site confirmed its role as a secondary exchange pathway in modulating Xe diffusion. This shows the possibility for site-specifically controlling xenon protein-solvent exchange. Analysis of the available MBP structures suggests a biological role of MBP’s large hydrophobic cavity to accommodate structural changes associated with ligand binding and protein-protein interactions.  相似文献   

5.
NMR studies with hyperpolarized xenon as functionalized sensor or contrast agent recently made notable progress in developing a new approach for detecting molecular markers and parameters of biomedical interest. Combining spin polarization enhancement with novel indirect detection schemes easily enables a 107-fold signal gain, thus having promising potential to solve the NMR sensitivity problem in many applications. Though an inert element, 129Xe has exquisite NMR properties to sense molecular environments. This review summarizes recent developments in the production of hyperpolarized xenon and the design and detection schemes of xenon biosensors.  相似文献   

6.
For detection of biological events in vitro, sensors using hyperpolarized (129)Xe NMR can become a powerful tool, provided the approach can bridge the gap in sensitivity. Here we propose constructs based on the non-selective grafting of cryptophane precursors on holo-transferrin. This biological system was chosen because there are many receptors on the cell surface, and endocytosis further increases this density. The study of these biosensors with K562 cell suspensions via fluorescence microscopy and (129)Xe NMR indicates a strong interaction, as well as interesting features such as the capacity of xenon to enter the cryptophane even when the biosensor is endocytosed, while keeping a high level of polarization. Despite a lack of specificity for transferrin receptors, undoubtedly due to the hydrophobic character of the cryptophane moiety that attracts the biosensor into the cell membrane, these biosensors allow the first in-cell probing of biological events using hyperpolarized xenon.  相似文献   

7.
8.
Xenon-binding sites in proteins have led to a number of applications of xenon in biochemical and structural studies. Here we further develop the utility of 129Xe NMR in characterizing specific xenon-protein interactions. The sensitivity of the 129Xe chemical shift to its local environment and the intense signals attainable by optical pumping make xenon a useful NMR reporter of its own interactions with proteins. A method for detecting specific xenon-binding interactions by analysis of 129Xe chemical shift data is illustrated using the maltose binding protein (MBP) from Escherichia coli as an example. The crystal structure of MBP in the presence of 8atm of xenon confirms the binding site determined from NMR data. Changes in the structure of the xenon-binding cavity upon the binding of maltose by the protein can account for the sensitivity of the 129Xe chemical shift to MBP conformation. 129Xe NMR data for xenon in solution with a number of cavity containing phage T4 lysozyme mutants show that xenon can report on cavity structure. In particular, a correlation exists between cavity size and the binding-induced 129Xe chemical shift. Further applications of 129Xe NMR to biochemical assays, including the screening of proteins for xenon binding for crystallography are considered.  相似文献   

9.
Hyperpolarized 129Xe was dissolved in a lipid emulsion and administered to anaesthetized rats by manual injections into the carotid (approximately 1-1.5 mL in a maximum time of 30 s). During injection, 129Xe NMR brain spectra at 2.35 T were recorded over 51 s, with a repetition time of 253 ms. Two peaks assigned to dissolved 129Xe were observed (the larger at 194 +/- 1 ppm assigned to intravascular xenon and the smaller at 199 +/- 1 ppm to xenon dissolved in the brain tissue). Their kinetics revealed a rapid intensity increase, followed by a plateau (approximately 15 s duration) and then a decrease over 5 s. This behaviour was attributed to combined influences of the T1 relaxation of the tracer, of radiofrequency sampling, and of the tracer perfusion rate in rat brain. Similar kinetics were observed in experiments carried out on a simple micro-vessel phantom. An identical experimental set-up was used to acquire a series of 2D projection 129Xe images on the phantom and the rat brain.  相似文献   

10.
Nuclear magnetic resonance (NMR) spectroscopy and imaging (MRI) suffer from intrinsic low sensitivity because even strong external magnetic fields of ~10 T generate only a small detectable net-magnetization of the sample at room temperature 1. Hence, most NMR and MRI applications rely on the detection of molecules at relative high concentration (e.g., water for imaging of biological tissue) or require excessive acquisition times. This limits our ability to exploit the very useful molecular specificity of NMR signals for many biochemical and medical applications. However, novel approaches have emerged in the past few years: Manipulation of the detected spin species prior to detection inside the NMR/MRI magnet can dramatically increase the magnetization and therefore allows detection of molecules at much lower concentration 2.Here, we present a method for polarization of a xenon gas mixture (2-5% Xe, 10% N2, He balance) in a compact setup with a ca. 16000-fold signal enhancement. Modern line-narrowed diode lasers allow efficient polarization 7 and immediate use of gas mixture even if the noble gas is not separated from the other components. The SEOP apparatus is explained and determination of the achieved spin polarization is demonstrated for performance control of the method.The hyperpolarized gas can be used for void space imaging, including gas flow imaging or diffusion studies at the interfaces with other materials 8,9. Moreover, the Xe NMR signal is extremely sensitive to its molecular environment 6. This enables the option to use it as an NMR/MRI contrast agent when dissolved in aqueous solution with functionalized molecular hosts that temporarily trap the gas 10,11. Direct detection and high-sensitivity indirect detection of such constructs is demonstrated in both spectroscopic and imaging mode.  相似文献   

11.
The apparent diffusion coefficients (ADCs) of hyperpolarized (3)He and (129)Xe gases were measured in the lungs of rabbits with elastase-induced emphysema and correlated against the mean chord length from lung histology. In vivo measurements were performed at baseline and 2, 4, 6, and 8 wk after instillation of elastase (mild and moderate emphysema groups) or saline (control group). ADCs were determined from acquisitions that used two b values. To investigate the effect of b value on the results, b-value pairs of 0 and 1.6 s/cm(2) and 0 and 4.0 s/cm(2) were used for (3)He, and b-value pairs of 0 and 5.0 s/cm(2) and 0 and 10.0 s/cm(2) were used for (129)Xe. At 8 wk after instillation, the rabbits were euthanized, and the lungs were analyzed histologically and morphometrically. ADCs for the rabbits in the control group did not change significantly from baseline to week 8, whereas ADCs for the rabbits in the emphysema groups increased significantly (P < 0.05) for all gas and b-value combinations except (129)Xe with the b-value pair of 0 and 5.0 s/cm(2). The largest percent change in mean ADC from baseline to week 8 (15.3%) occurred with (3)He and the b-value pair of 0 and 1.6 s/cm(2) for rabbits in the moderate emphysema group. ADCs (all b values) were strongly correlated (r = 0.62-0.80, P < 0.001) with mean chord lengths from histology. These results further support the ability of diffusion-weighted MRI with hyperpolarized gases to detect regional and global structural changes of emphysema within the lung.  相似文献   

12.
Cryptophane-A has generated considerable interest based on its high affinity for xenon and potential for creating biosensors for (129)Xe nuclear magnetic resonance (NMR) spectroscopy. Here, we report the cellular delivery of three peptide-functionalized cryptophane biosensors. Cryptophanes were delivered using two cationic cell penetrating peptides into several human cancer and normal cell lines. An RGD peptide targeting alpha(v)beta(3) integrin receptor was shown to increase specificity of cryptophane cell uptake. Labeling the peptides with Cy3 made it possible to monitor cellular delivery using confocal laser scanning microscopy. The peptido-cryptophanes were determined to be relatively nontoxic by MTT assay at the micromolar cryptophane concentrations that are required for (129)Xe NMR biosensing experiments.  相似文献   

13.
Experiments were carried out on conscious rabbits with electrodes chronically implanted into sensorimotor cortex (MSC), ventro-postero-lateral thalamic nuclei (NVPL), periaqueductal grey matter (PAG) and midbrain reticular formation (MRF). Thermal pain stimulus (52 degrees C) lasted 10 s and was applied to the forepaw of the animal. Analysis of bioelectrical activity (20 sec periods) before and after the stimulation was performed by means of automatic methods using the algorithm of Fast Fourier Transform (FFT). It was found that pain stimulation resulted in a characteristic response in every studied structure and that this response was blocked by morphine.  相似文献   

14.
In this article we focus on the interaction between a chiral molecule and a single achiral molecule or an ensemble of achiral molecules. The desymmetrization of the achiral molecules resulting from this interaction is described as "chiralization." By analogy with electric polarization, we factorize chiralization into three factors, i.e., orientation, atomic, and electronic terms. Chiralization depends on the dipolar polarizability of the chiralized molecule but also on polarizabilities of higher order. The experimental part of this work is devoted to the electronic chiralization of a xenon atom and its observation by (129)Xe NMR spectroscopy. Copyright 2000 Wiley-Liss, Inc.  相似文献   

15.
Brain MR imaging techniques are important ancillary tests in the diagnosis of a suspected mitochondrial encephalopathy since they provide details on brain structural and metabolic abnormalities. This is particularly true in children where non-specific neurologic symptoms are common, biochemical findings can be marginal and genetic defects may be not discovered. MR imaging modalities include conventional, or structural, imaging (MRI) and functional, or ultrastructural, imaging (spectroscopy, MRS; diffusion, DWI-ADC; perfusion, DSCI––ASL). Among them MRI and MRS are the main tools for diagnosis and work up of MD, and this review will focus mainly on them. The MRI findings of MD are very heterogeneous, as they depend on the metabolic brain defects, age of the patient, stage and severity of the disease. No correlation has been found between genetic defects and neuroimaging picture; however, some relationships between MR findings and clinical phenotypes may be identified. Different combinations of MRI signal abnormalities are often encountered but the most common findings may be summarized into three main MR patterns: (i) non-specific; (ii) specific; (iii) leukodystrophic-like. Regarding the functional MR techniques, only proton MRS plays an important role in demonstrating an oxidative metabolism impairment in the brain since it can show the accumulation of lactate, present as a doublet peak at 1.33 ppm. Assessment of lactate should be always performed on brain tissue and on the ventricular cerebral spinal fluid. As for MRI, metabolic MRS abnormalities can be of different types, and two distinct patterns can be recognized: non-specific and specific. The specific metabolic profiles, although not frequent to find, are highly pathognomonic of MD. The un-specific metabolic profiles add value to structural images in allowing to define the lesion load and to monitor the response to therapy trials.  相似文献   

16.
The chemical shift of the (129)Xe NMR signal has been shown to be extremely sensitive to the local environment around the atom and has been used to follow processes such as ligand binding by bacterial periplasmic binding proteins. Here we show that the (129)Xe shift can sense more subtle changes: magnesium binding, BeF(3)(-) activation, and peptide binding by the Escherichia coli chemotaxis Y protein. (1)H-(15)N correlation spectroscopy and X-ray crystallography were used to identify two xenon-binding cavities in CheY that are primarily responsible for the shift changes. One site is near the active site, and the other is near the peptide binding site.  相似文献   

17.
The interaction of xenon with copper/6-hydroxydopa (2,4,5-trihydroxyphenethylamine) quinone (TPQ) amine oxidases from the plant pulses lentil (Lens esculenta) and pea (Pisum sativum) (seedlings), the perennial Mediterranean shrub Euphorbia characias (latex), and the mammals cattle (serum) and pigs (kidney), were investigated by NMR and optical spectroscopy of the aqueous solutions of the enzymes. (129)Xe chemical shift provided evidence of xenon binding to one or more cavities of all these enzymes, and optical spectroscopy showed that under 10 atm of xenon gas, and in the absence of a substrate, the plant enzyme cofactor (TPQ), is converted into its reduced semiquinolamine radical. The kinetic parameters of the analyzed plant amine oxidases showed that the k(c) value of the xenon-treated enzymes was reduced by 40%. Moreover, whereas the measured K(m) value for oxygen and for the aromatic monoamine benzylamine was shown to be unchanged, the K(m) value for the diamine putrescine increased remarkably after the addition of xenon. Under the same experimental conditions, the TPQ of bovine serum amine oxidase maintained its oxidized form, whereas in pig kidney, the reduced aminoquinol species was formed without the radical species. Moreover the k(c) value of the xenon-treated pig enzyme in the presence of both benzylamine and cadaverine was shown to be dramatically reduced. It is proposed that the lysine residue at the active site of amine oxidase could be involved both in the formation of the reduced TPQ and in controlling catalytic activity.  相似文献   

18.
The objective of this study was to evaluate the regional effects of bronchodilator administration in chronic obstructive pulmonary disease (COPD) using hyperpolarized helium-3 ((3)He) MRI apparent diffusion coefficient (ADC). Ten COPD ex-smokers provided written, informed consent and underwent diffusion-weighted, hyperpolarized (3)He MRI, spirometry, and plethysmography before and 25 ± 2 min after bronchodilator administration. Pre- and postsalbutamol whole-lung (WL) ADC maps were generated and registered together to identify the lung regions containing the (3)He signal at both time points, and mean ADC within those regions of interest (ROI) was determined for a measurement of previously ventilated ROI ADC (ADC(P)). Lung ROI with (3)He signal at both time points was used as a binary mask on postsalbutamol WL ADC maps to obtain an ADC measurement for newly ventilated ROI (ADC(N)). Postsalbutamol, no significant differences were detected in WL ADC (P = 0.516). There were no significant differences between ADC(N) and ADC(P) postsalbutamol (P = 1.00), suggesting that the ADC(N) lung regions were not more emphysematous than the lung ROI participating in ventilation before bronchodilator administration. Postsalbutamol, a statistically significant decrease in ADC(P) (P = 0.01) was detected, and there were significant differences between ADC(P) in the most anterior and most posterior image slices (P = 0.02), suggesting a reduction in regional gas trapping following bronchodilator administration. Regional evaluation of tissue microstructure using hyperpolarized (3)He MRI ADC provides insights into lung alterations that accompany improvements in regional (3)He gas distribution after bronchodilator administration.  相似文献   

19.
To understand the functional role of apolar cavities in bacteriorhodopsin, a light-driven proton pump found in Halobacterium salinarum, we investigated the crystal structure in pressurized xenon or krypton. Diffraction data from the P622 crystal showed that one Xe or Kr atom binds to a preexisting hydrophobic cavity buried between helices C and D, located at the same depth from the membrane surface as Asp96, a key residue in the proton uptake pathway. The occupation fraction of Xe or Kr was calculated as approximately 0.32 at a pressure of 1 MPa. In the unphotolyzed state, the binding of Xe or Kr caused no large deformation of the cavity. However, the proton pumping cycle was greatly perturbed when an aqueous suspension of purple membrane was pressurized with xenon gas; that is, the decay of the M state was accelerated significantly (~5 times at full occupancy), while the decay of an equilibrium state of N and O was slightly decelerated. A similar but much smaller perturbation in the reaction kinetics was observed upon pressurization with krypton gas. In a glycerol/water mixture, xenon-induced acceleration of M decay became less significant in proportion to the water activity. Together with the structure of the xenon-bound protein, these observations suggest that xenon binding helps water molecules permeate into apolar cavities in the proton uptake pathway, thereby accelerating the water-mediated proton transfer from Asp96 to the Schiff base.  相似文献   

20.
Acute nodularin-induced hepatotoxicity was assessed in vivo, in rats using magnetic resonance (MR) techniques, including MR imaging (MRI), MR spectroscopy (MRS), and electron paramagnetic resonance (EPR) oximetry. Nodularin is a cyclic hepatotoxin isolated from the cyanobacterium Nodularia spumigena. Three hours following the intraperitoneal (i.p.) administration of nodularin (LD50), a region of 'damage', characterized by an increase in signal intensity, was observed proximal to the porta hepatis (PH) region in T2-weighted MR images of rat liver. Image analysis of these regions of apparent 'damage' indicated a statistically significant increase in signal intensity around the PH region following nodularin administration, in comparison with controls and regions peripheral to the PH region. An increase in signal intensity was also observed proximal to the PH region in water chemical shift selective images (CSSI) of nodularin-treated rat livers, indicating that the increased signal observed by MRI is an oedematous response to the toxin. Microscopic assessment (histology and electron microscopy) and serum liver enzyme function tests (aminotransferase (ALT) and aspartate ALT (AST)) confirmed the nodularin-induced tissue injury observed by MRI. In vivo and in vitro MRS was used to detect alterations in metabolites, such as lipids, Glu+Gln, and choline, during the hepatotoxic response (2-3 h post-exposure). Biochemical assessment of perchloric acid extracts of nodularin-treated rat livers were used to confirm the MRS results. In vivo EPR oximetry was used to monitor decreasing hepatic pO2 (approximately 2-fold from controls) 2-3 h following nodularin exposure. In vivo MR techniques (MRI, MRS and EPR oximetry) are able to highlight effects that may not have been evident in single end point studies, and are ideal methods to follow tissue injury progression in longitudinally, increasing the power of a study through repeated measures, and decreasing the number of animals to perform a similar study using histological or biochemical techniques.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号