首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We examined the effects of positive end-expiratory pressure (PEEP) and tidal volume on the distribution of ventilation and perfusion in a canine model of asymmetric lung injury. Unilateral right lung edema was established in 10 animals by use of a selective infusion of ethchlorvynol. Five animals were tested in the supine position (horizontal asymmetry) and five in the right decubitus position (vertical asymmetry). Raising PEEP from 5 to 12 cmH2O improved oxygenation despite a redistribution of blood flow toward the damage lung and a consistent decrease in total respiratory system compliance. This improvement paralleled a redistribution of tidal ventilation to the injured lung. This was effected primarily by a fall in the compliance of the noninjured lung due to hyperinflation. The effects of higher tidal volume were additive to those of PEEP. We propose that the major effect of PEEP in inhomogeneous lung injury is to restore tidal ventilation to a population of alveoli recruitable only at high airway pressures.  相似文献   

2.
We attempted to determine whether stimulation of pulmonary rapidly adapting receptors (RARs) increase tracheal submucosal gland secretion in anesthetized open-chest dogs. Electroneurographic studies of pulmonary afferents established that RARs but not lung C-fibers were stimulated by intermittent lung collapse during deflation, collapse being produced by removing positive end-expiratory pressure (PEEP, 4 cmH2O) or by applying negative end-expiratory pressure (NEEP, -4 cmH2O). We measured tracheal secretion by the "hillocks" method. Removing PEEP or applying NEEP for 1 min increased secretion from a base line of 6.0 +/- 1.1 to 11.8 +/- 1.7 and 22.0 +/- 2.8 hillocks.cm-2.min-1, respectively (P less than 0.005). After PEEP was restored, dynamic lung compliance (Cdyn) was 37% below control, and secretion remained elevated (P less than 0.05). A decrease in Cdyn stimulates RARs but not other pulmonary afferents. Hyperinflation, which restored Cdyn and RAR activity to control, returned secretion rate to base line. Secretory responses to lung collapse were abolished by vagal cooling (6 degrees C), by pulmonary vagal section, or by atropine. We conclude that RAR stimulation reflexly increases airway secretion. We cannot exclude the possibility that reduced input from slowly adapting stretch receptors contributed to the secretory response.  相似文献   

3.
In mature lungs, elevated positive end-expiratory pressure (PEEP) reduces pulmonary blood flow (PBF) and increases pulmonary vascular resistance (PVR). However, the effect of PEEP on PBF in preterm infants with immature lungs and a patent ductus arteriosus is unknown. Fetal sheep were catheterized at 124 days of gestation (term approximately 147 days), and a flow probe was placed around the left pulmonary artery to measure PBF. At 127 days, lambs were delivered and ventilated from birth with a tidal volume of 5 ml/kg and 4-cmH(2)O PEEP; PEEP was changed to 0, 8, and 12 cmH(2)O in random order, returning to 4 cmH(2)O between each change. Increasing PEEP from 4 to 8 cmH(2)O and from 4 to 12 cmH(2)O decreased PBF by 20.5 and 41.0%, respectively, and caused corresponding changes in PVR; reducing PEEP from 4 to 0 cmH(2)O did not affect PBF. Despite decreasing PBF, increasing PEEP from 4 to 8 cmH(2)O and 12 cmH(2)O improved oxygenation of lambs. Increasing and decreasing PEEP from 4 cmH(2)O significantly changed the contour of the PBF waveform; at a PEEP of 12 cmH(2)O, end-diastolic flow was reduced by 82.8% and retrograde flow was reestablished. Although increasing PEEP improves oxygenation, it adversely affects PBF and PVR shortly after birth, alters the PBF waveform, and reestablishes retrograde flow during diastole.  相似文献   

4.
We investigated the dose-response effect of positive end-expiratory pressure (PEEP) and increased lung volume on the pulmonary clearance rate of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). Clearance of lung radioactivity was expressed as percent decrease per minute. Base-line clearance was measured while anesthetized sheep (n = 20) were ventilated with 0 cmH2O end-expiratory pressure. Clearance was remeasured during ventilation at 2.5, 5, 10, 15, or 20 cmH2O PEEP. Further studies showed stepwise increases in functional residual capacity (FRC) (P less than 0.05) measured at 0, 2.5, 5, 10, 15, and 20 cmH2O PEEP. At 2.5 cmH2O PEEP, the clearance rate was not different from that at base line (P less than 0.05), although FRC was increased from base line. Clearance rate increased progressively with increasing PEEP at 5, 10, and 15 cmH2O (P less than 0.05). Between 15 and 20 cmH2O PEEP, clearance rate was again unchanged, despite an increase in FRC. The pulmonary clearance of aerosolized 99mTc-DTPA shows a sigmoidal response to increasing FRC and PEEP, having both threshold and maximal effects. This relationship is most consistent with the hypothesis that alveolar epithelial permeability is increased by lung inflation.  相似文献   

5.
Effect of inspiratory resistance and PEEP on 99mTc-DTPA clearance   总被引:1,自引:0,他引:1  
Experiments were performed to determine the effect of markedly negative pleural pressure (Ppl) or positive end-expiratory pressure (PEEP) on the pulmonary clearance (k) of technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA). A submicronic aerosol containing 99mTc-DTPA was insufflated into the lungs of anesthetized intubated sheep. In six experiments k was 0.44 +/- 0.46% (SD)/min during the initial 30 min and was unchanged during the subsequent 30-min interval [k = 0.21 +/- 12%/min] when there was markedly increased inspiratory resistance. A 3-mm-diam orifice in the inspiratory tubing created the resistance. It resulted on average in a 13-cmH2O decrease in inspiratory Ppl. In eight additional experiments sheep were exposed to 2, 10, and 15 cmH2O PEEP (20 min at each level). During 2 cmH2O PEEP k = 0.47 +/- 0.15%/min, and clearance increased slightly at 10 cmH2O PEEP [0.76 +/- 0.28%/min, P less than 0.01]. When PEEP was increased to 15 cmH2O a marked increase in clearance occurred [k = 1.95 +/- 1.08%/min, P less than 0.001]. The experiments demonstrate that markedly negative inspiratory pressures do not accelerate the clearance of 99mTc-DTPA from normal lungs. The effect of PEEP on k is nonlinear, with large effects being seen only with very large increases in PEEP.  相似文献   

6.
Effect of PEEP on discharge of pulmonary C-fibers in dogs   总被引:1,自引:0,他引:1  
Although positive end-expiratory pressure (PEEP) is believed to depress cardiac output and arterial pressure by compressing the vena cava and the heart, it is unclear whether PEEP also depresses these variables by a reflex arising from an inflation-induced stimulation of pulmonary C-fibers. We therefore recorded the impulse activity of 17 pulmonary C-fibers in barbiturate-anesthetized dogs with closed chests, while we placed the expiratory outlet of a ventilator under 5-30 cmH2O. Increasing PEEP in a ramp-like manner stimulated 12 of the 17 pulmonary C-fibers, with activity increasing from 0.0 +/- 0.1 to 0.9 +/- 0.2 imp/s when end-expiratory pressure equaled 15 cmH2O. When PEEP was increased in a stepwise manner to 15-20 cmH2O and maintained at this pressure for 15 min, pulmonary C-fibers increased their firing rates, but the effect was small averaging 0.2-0.3 imp/s after the 1st min of this maneuver. We conclude that pulmonary C-fibers are unlikely to be responsible for causing much of the decreases in cardiac output and arterial pressure evoked by sustained periods of PEEP in both patients and laboratory animals. These C-fibers, however, are likely to be responsible for causing the reflex decreases in these variables evoked by sudden application of PEEP.  相似文献   

7.
We examined the steady-state response of slowly adapting pulmonary stretch receptors (SAPSRs) to reduced lung compliance in open-chest cats with lungs ventilated at eupneic rate and tidal volume (VT) and with a positive end-expiratory pressure (PEEP) of 3-4 cmH2O. Transient removal of PEEP decreased compliance by approximately 30% and increased transpulmonary pressure (Ptp) by 1-2.5 cmH2O. Reduction of compliance significantly decreased SAPSR discharge in deflation and caused a small increase in discharge at the peak of inflation; it had little effect on discharge averaged over the ventilatory cycle. Increasing VT to produce a comparable increase in Ptp significantly increased peak discharge. Thus unlike rapidly adapting receptors, whose discharge is increased more effectively by reduced compliance than by increased VT, SAPSRs are stimulated by increased VT but not by reduced compliance. We speculate that the most consistent effect of reduced compliance on SAPSRs (the decrease in deflation discharge) was due to the decreased time constant for deflation in the stiffer lung. This alteration in firing may contribute to the tachypnea evoked as the lungs become stiffer.  相似文献   

8.
We have recently shown in dogs that much of the increase in lung resistance (RL) after induced constriction can be attributed to increases in tissue resistance, the pressure drop in phase with flow across the lung tissues (Rti). Rti is dependent on lung volume (VL) even after induced constriction. As maximal responses in RL to constrictor agonists can also be affected by changes in VL, we questioned whether changes in the plateau response with VL could be attributed in part to changes in the resistive properties of lung tissues. We studied the effect of changes in VL on RL, Rti, airway resistance (Raw), and lung elastance (EL) during maximal methacholine (MCh)-induced constriction in 8 anesthetized, paralyzed, open-chest mongrel dogs. We measured tracheal flow and pressure (Ptr) and alveolar pressure (PA), the latter using alveolar capsules, during tidal ventilation [positive end-expiratory pressure (PEEP) = 5.0 cmH2O, tidal volume = 15 ml/kg, frequency = 0.3 Hz]. Measurements were recorded at baseline and after the aerosolization of increasing concentrations of MCh until a clear plateau response had been achieved. VL was then altered by changing PEEP to 2.5, 7.5, and 10 cmH2O. RL changed only when PEEP was altered from 5 to 10 cmH2O (P < 0.01). EL changed when PEEP was changed from 5 to 7.5 and 5 to 10 cmH2O (P < 0.05). Rti and Raw varied significantly with all three maneuvers (P < 0.05). Our data demonstrate that the effects of VL on the plateau response reflect a complex combination of changes in tissue resistance, airway caliber, and lung recoil.  相似文献   

9.
We examined the effects of lung volume on the bronchoconstriction induced by inhaled aerosolized methacholine (MCh) in seven normal subjects. We constructed dose-response curves to MCh, using measurements of inspiratory pulmonary resistance (RL) during tidal breathing at functional residual capacity (FRC) and after a change in end-expiratory lung volume (EEV) to either FRC -0.5 liter (n = 5) or FRC +0.5 liter (n = 2). Aerosols of MCh were generated using a nebulizer with an output of 0.12 ml/min and administered for 2 min in progressively doubling concentrations from 1 to 256 mg/ml. After MCh, RL rose from a base-line value of 2.1 +/- 0.3 cmH2O. 1-1 X s (mean +/- SE; n = 7) to a maximum of 13.9 +/- 1.8. In five of the seven subjects a plateau response to MCh was obtained at FRC. There was no correlation between the concentration of MCh required to double RL and the maximum value of RL. The dose-response relationship to MCh was markedly altered by changing lung volume. The bronchoconstrictor response was enhanced at FRC - 0.5 liter; RL reached a maximum of 39.0 +/- 4.0 cmH2O X 1-1 X s. Conversely, at FRC + 0.5 liter the maximum value of RL was reduced in both subjects from 8.2 and 16.6 to 6.0 and 7.7 cmH2O X 1-1 X s, respectively. We conclude that lung volume is a major determinant of the bronchoconstrictor response to MCh in normal subjects. We suggest that changes in lung volume act to alter the forces of interdependence between airways and parenchyma that oppose airway smooth muscle contraction.  相似文献   

10.
We determined the influence of several factors on lung solute clearance using aerosolized 99mTc-diethylenetriaminepentaacetate. We used a jet nebulizer-plate separator-balloon system to generate particles with an activity median aerodynamic diameter of 1.1 micron, administered the aerosol in a standard fashion, and determined clearance half times (t1/2) with a gamma-scintillation camera. The following serial studies were performed in five anesthetized, paralyzed, intubated, mechanically ventilated dogs: 1) control, with ventilatory frequency (f) = 15 breaths/min and tidal volume (VT) = 15 ml/kg during solute clearance; 2) repeat control, for reproducibility; 3) increased frequency, with f = 25 breaths/min and VT = 10 ml/kg; 4) positive end-expiratory pressure (PEEP) of 10 cmH2O; 5) unilateral pulmonary arterial occlusion (PAO); and 6) bronchial arterial occlusion (BAO). Control t1/2 was 25 +/- 5 min and did not change in the repeat control, increased frequency, or BAO experiments. PEEP markedly decreased t1/2 to 13 +/- 3 min (P less than 0.01), and PAO increased it to 37 +/- 6 min (P less than 0.05). We conclude that clearance from the lungs by our method is uninfluenced by increased frequency, increases markedly with PEEP, and depends on pulmonary, not bronchial, blood flow.  相似文献   

11.
Although increased lung expansion markedly alters lung growth and epithelial cell differentiation during fetal life, the effect of increasing lung expansion after birth is unknown. We hypothesized that increased basal lung expansion, caused by ventilating newborn lambs with a positive end-expiratory pressure (PEEP), would stimulate lung growth and alter alveolar epithelial cell (AEC) proportions and decrease surfactant protein mRNA levels. Two groups of lambs were sedated and ventilated with either 0 cmH(2)O PEEP (controls, n = 5) or 10 cmH(2)O PEEP (n = 5) for 48 h beginning at 15 +/- 1 days after normal term birth. A further group of nonventilated 2-wk-old lambs was used for comparison. We determined wet and dry lung weights, DNA and protein content, a labeling index for proliferating cells, surfactant protein mRNA expression, and proportions of AECs using electron microscopy. Although ventilating lambs for 48 h with 10 cmH(2)O PEEP did not affect total lung DNA or protein, it significantly increased the proportion of proliferating cells in the lung when compared with nonventilated 2-wk-old controls and lambs ventilated with 0 cmH(2)O PEEP (control: 2.6 +/- 0.5%; 0 PEEP: 1.9 +/- 0.3%; 10 PEEP: 3.5 +/- 0.3%). In contrast, no differences were observed in AEC proportions or surfactant protein mRNA levels between either of the ventilated groups. This study demonstrates that increases in end-expiratory lung volumes, induced by the application of PEEP, lead to increased lung growth in mechanically ventilated 2-wk-old lambs but do not alter the proportions of AECs.  相似文献   

12.
The aim of this study was to assess the utility of (3)He MRI to noninvasively probe the effects of positive end-expiratory pressure (PEEP) maneuvers on alveolar recruitment and atelectasis buildup in mechanically ventilated animals. Sprague-Dawley rats (n = 13) were anesthetized, intubated, and ventilated in the supine position ((4)He-to-O(2) ratio: 4:1; tidal volume: 10 ml/kg, 60 breaths/min, and inspiration-to-expiration ratio: 1:2). Recruitment maneuvers consisted of either a stepwise increase of PEEP to 9 cmH(2)O and back to zero end-expiratory pressure or alternating between these two PEEP levels. Diffusion MRI was performed to image (3)He apparent diffusion coefficient (ADC) maps in the middle coronal slices of lungs (n = 10). ADC was measured immediately before and after two recruitment maneuvers, which were separated from each other with a wait period (8-44 min). We detected a statistically significant decrease in mean ADC after each recruitment maneuver. The relative ADC change was -21.2 ± 4.1 % after the first maneuver and -9.7 ± 5.8 % after the second maneuver. A significant relative increase in mean ADC was observed over the wait period between the two recruitment maneuvers. The extent of this ADC buildup was time dependent, as it was significantly related to the duration of the wait period. The two postrecruitment ADC measurements were similar, suggesting that the lungs returned to the same state after the recruitment maneuvers were applied. No significant intrasubject differences in ADC were observed between the corresponding PEEP levels in two rats that underwent three repeat maneuvers. Airway pressure tracings were recorded in separate rats undergoing one PEEP maneuver (n = 3) and showed a significant relative difference in peak inspiratory pressure between pre- and poststates. These observations support the hypothesis of redistribution of alveolar gas due to recruitment of collapsed alveoli in presence of atelectasis, which was also supported by the decrease in peak inspiratory pressure after recruitment maneuvers.  相似文献   

13.
We have reported that left atrial blood refluxes through the pulmonary veins to gas-exchanging tissue after pulmonary artery ligation. This reverse pulmonary venous flow (Qrpv) was observed only when lung volume was changed by ventilation. This was believed to drive Qrpv by alternately distending and compressing the alveolar and extra-alveolar vessels. Because lung and pulmonary vascular compliances change with lung volume, we studied the effect of positive end-expiratory pressure (PEEP) on the magnitude of Qrpv during constant-volume ventilation. In prone anesthetized goats (n = 8), using the right lung to maintain normal blood gases, we ligated the pulmonary and bronchial arterial inflow to the left lung and ventilated each lung separately. A solution of SF6, an inert gas, was infused into the left atrium. SF6 clearance from the left lung was determined by the Fick principle at 0, 5, 10, and 15 and again at 0 cmH2O PEEP and was used to measure Qrpv. Left atrial pressure remained nearly constant at 20 cmH2O because the increasing levels of PEEP were applied to the left lung only. Qrpv was three- to fourfold greater at 10 and 15 than at 0 cmH2O PEEP. At these higher levels of PEEP, there were greater excursions in alveolar pressure for the same ventilatory volume. We believe that larger excursions in transpulmonary pressure during tidal ventilation at higher levels of PEEP, which compressed alveolar vessels, resulted in the reflux of greater volumes of left atrial blood, through relatively noncompliant extra-alveolar veins into alveolar corner vessels, and more compliant extra-alveolar arteries.  相似文献   

14.
Nonlinear hemodynamic responses on positive end-expiratory pressure (PEEP) have been attributed to a rise of mean central venous pressure (Pcv), to compensatory cardiovascular control mechanisms, and to the occurrence of a lung stretch depressor reflex above a threshold lung stretch. We tested the hypothesis that the contribution of each of these mechanisms is dependent on the preexisting volemic load. PEEP was applied as a continuous rise (ramp) in piglets in three different volemic loads. In the normovolemic circulation cardiac output (CO) decreased nonlinearly in three phases during the PEEP ramp up to 15 cmH2O. CO decreased gradually in phase I, followed by a sharp decrease in phase II between a PEEP of 3 and 9 cmH2O and again a more gradual decrease in phase III up to a PEEP of 15 cmH2O. Heart rate (HR) and mean aortic pressure (PaO) also decreased during phase II, indicating the predominance of a lung stretch depressor reflex. In the hypervolemic circulation (loading 15 ml . kg-1 dextran) only phases I and II were observed with the onset of phase II at a higher level of PEEP (6 cmH2O). More lung stretch appeared to be necessary to elicit the lung stretch depressor reflex. In the hypovolemic circulation (hemorrhage 15 ml . kg-1) CO decreased linearly, Pao was stable after an initial decrease, and HR increased continuously, indicating a predominance of cardiovascular compensatory mechanisms.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
Constant-flow ventilation (CFV) maintains alveolar ventilation without tidal excursion in dogs with normal lungs, but this ventilatory mode requires high CFV and bronchoscopic guidance for effective subcarinal placement of two inflow catheters. We designed a circuit that combines CFV with continuous positive-pressure ventilation (CPPV; CFV-CPPV), which negates the need for bronchoscopic positioning of CFV cannula, and tested this system in seven dogs having oleic acid-induced pulmonary edema. Addition of positive end-expiratory pressure (PEEP, 10 cmH2O) reduced venous admixture from 44 +/- 17 to 10.4 +/- 5.4% and kept arterial CO2 tension (PaCO2) normal. With the innovative CFV-CPPV circuit at the same PEEP and respiratory rate (RR), we were able to reduce tidal volume (VT) from 437 +/- 28 to 184 +/- 18 ml (P less than 0.001) and elastic end-inspiratory pressures (PEI) from 25.6 +/- 4.6 to 17.7 +/- 2.8 cmH2O (P less than 0.001) without adverse effects on cardiac output or pulmonary exchange of O2 or CO2; indeed, PaCO2 remained at 35 +/- 4 Torr even though CFV was delivered above the carina and at lower (1.6 l.kg-1.min-1) flows than usually required to maintain eucapnia during CFV alone. At the same PEEP and RR, reduction of VT in the CPPV mode without CFV resulted in CO2 retention (PaCO2 59 +/- 8 Torr). We conclude that CFV-CPPV allows CFV to effectively mix alveolar and dead spaces by a small bulk flow bypassing the zone of increased resistance to gas mixing, thereby allowing reduction of the CFV rate, VT, and PEI for adequate gas exchange.  相似文献   

16.
In spontaneously breathing subjects, intrathoracic expiratory flow limitation can be detected by applying a negative expiratory pressure (NEP) at the mouth during tidal expiration. To assess whether NEP might increase upper airway resistance per se, the interrupter resistance of the respiratory system (Rint,rs) was computed with and without NEP by using the flow interruption technique in 12 awake healthy subjects, 6 nonsnorers (NS), and 6 nonapneic snorers (S). Expiratory flow (V) and Rint,rs were measured under control conditions with V increased voluntarily and during random application of brief (0.2-s) NEP pulses from -1 to -7 cmH(2)O, in both the seated and supine position. In NS, Rint,rs with spontaneous increase in V and with NEP was similar [3.10 +/- 0.19 and 3.30 +/- 0.18 cmH(2)O x l(-1) x s at spontaneous V of 1.0 +/- 0.01 l/s and at V of 1.1 +/- 0.07 l/s with NEP (-5 cmH(2)O), respectively]. In S, a marked increase in Rint,rs was found at all levels of NEP (P < 0.05). Rint,rs was 3.50 +/- 0.44 and 8.97 +/- 3.16 cmH(2)O x l(-1) x s at spontaneous V of 0.81 +/- 0.02 l/s and at V of 0.80 +/- 0.17 l/s with NEP (-5 cmH(2)O), respectively (P < 0.05). With NEP, Rint,rs was markedly higher in S than in NS both seated (F = 8.77; P < 0.01) and supine (F = 9.43; P < 0.01). In S, V increased much less with NEP than in NS and was sometimes lower than without NEP, especially in the supine position. This study indicates that during wakefulness nonapneic S have more collapsible upper airways than do NS, as reflected by the marked increase in Rint,rs with NEP. The latter leads occasionally to an actual decrease in V such as to invalidate the NEP method for detection of intrathoracic expiratory flow limitation.  相似文献   

17.
The effect of ventilation strategy on in vivo function of different surfactants was evaluated in preterm rabbits delivered at 27 days gestational age and ventilated with either 0 cmH2O positive end-expiratory pressure (PEEP) at tidal volumes of 10-11 ml/kg or 3 cmH2O PEEP at tidal volumes of 7-8 ml/kg after treatment with one of four different surfactants: sheep surfactant, the lipids of sheep surfactant stripped of protein (LH-20 lipid), Exosurf, and Survanta. The use of 3 cmH2O PEEP decreased pneumothoraces in all groups except for the sheep surfactant group where pneumothoraces increased (P < 0.01). Ventilatory pressures (peak pressures - PEEP) decreased more with the 3 cmH2O PEEP, low-tidal-volume ventilation strategy for Exosurf-, Survanta-, and sheep surfactant-treated rabbits (P < 0.05), whereas ventilation efficiency indexes (VEI) improved only for Survanta- and sheep surfactant-treated rabbits with 3 cmH2O PEEP (P < 0.01). Pressure-volume curves for sheep surfactant-treated rabbits were better than for all other treated groups (P < 0.01), although Exosurf and Survanta increased lung volumes above those in control rabbits (P < 0.05). The recovery of intravascular radiolabeled albumin in the lungs and alveolar washes was used as an indicator of pulmonary edema. Only Survanta and sheep surfactant decreased protein leaks in the absence of PEEP, whereas all treatments decreased labeled albumin recoveries when 3 cmH2O PEEP was used (P < 0.05). These experiments demonstrate that ventilation style will alter a number of measurements of surfactant function, and the effects differ for different surfactants.  相似文献   

18.
The influence of age and posture on compliance of the rib cage (Crc) and diaphragm-abdomen (Cab) compartments of the chest wall was studied in 61 healthy adults (33 men, 28 women) aged 24-75 yr. Chest wall compliance (Cw) was measured by the weighted spirometer technique; Crc and Cab were derived from the slope of the relaxation line of the thoracoabdominal system obtained with two pairs of linearized magnetometers. While Cw was being measured, we monitored electrical activity of the abdominal external oblique muscle with a concentric needle electrode and thoracoabdominal configuration. In 52 subjects, the electromyogram did not show any abdominal muscle activity and the end-expiratory level never departed from the relaxed thoracoabdominal configuration, thus suggesting adequate respiratory muscle relaxation. Aging was associated with significant decreases in Crc and Cab. In the upright posture Crc decreased from 0.164 +/- 0.041 (mean +/- SD) l/cmH2O in the younger subjects (24-39 yr) to 0.114 +/- 0.027 l/cmH2O in the older subjects (55-75 yr). Cab concomitantly fell from 0.032 +/- 0.012 l/cmH2O to 0.020 +/- 0.007 l/cmH2O. These reductions were statistically significant (P less than 0.05-0.01) and were also present in the supine posture. Shifting from the seated to the supine posture did not cause any significant change in Cw but was invariably associated with a decrease in Crc and an increase in Cab.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
This study compared pathophysiological and biochemical indexes of acute lung injury in a saline-lavaged rabbit model with different ventilatory strategies: a control group consisting of moderate tidal volume (V(T)) (10-12 ml/kg) and low positive end-expiratory pressure (PEEP) (4-5 cmH(2)O); and three protective groups: 1) low V(T) (5-6 ml/kg) high PEEP, 2-3 cmH(2)O greater than the lower inflection point; 2) low V(T) (5-6 ml/kg), high PEEP (8-10 cmH(2)O); and 3) high-frequency oscillatory ventilation (HFOV). The strategy using PEEP > inflection point resulted in hypotension and barotrauma. HFOV attenuated the decrease in pulmonary compliance, the lung inflammation assessed by polymorphonuclear leukocyte infiltration and tumor necrosis factor-alpha concentration in the alveolar space, and pathological changes of the small airways and alveoli. Conventional mechanical ventilation using lung protection strategies (low V(T) high PEEP) only attenuated the decrease in oxygenation and pulmonary compliance. Therefore, HFOV may be a preferable option as a lung protection strategy.  相似文献   

20.
Pneumonia caused by Pseudomonas aeruginosa carries a high rate of morbidity and mortality. A lung-protective strategy using low tidal volume (V(T)) ventilation for acute lung injury improves patient outcomes. The goal of this study was to determine whether low V(T) ventilation has similar utility in severe P. aeruginosa infection. A cytotoxic P. aeruginosa strain, PA103, was instilled into the left lung of rats anesthetized with pentobarbital. The lung-protective effect of low V(T) (6 ml/kg) with or without high positive end-expiratory pressure (PEEP, 10 or 3 cmH(2)O) was then compared with high V(T) with low PEEP ventilation (V(T) 12 ml/kg, PEEP 3 cmH(2)O). Severe lung injury and septic shock was induced. Although ventilatory mode had little effect on the involved lung or septic physiology, injury to noninvolved regions was attenuated by low V(T) ventilation as indicated by the wet-to-dry weight ratio (W/D; 6.13 +/- 0.78 vs. 3.78 +/- 0.26, respectively) and confirmed by histopathological examinations. High PEEP did not yield a significant protective effect (W/D, 4.03 +/- 0.32) but, rather, caused overdistension of noninvolved lungs. Bronchoalveolar lavage revealed higher concentrations of TNF-alpha in the fluid of noninvolved lung undergoing high V(T) ventilation compared with those animals receiving low V(T). We conclude that low V(T) ventilation is protective in noninvolved regions and that the application of high PEEP attenuated the beneficial effects of low V(T) ventilation, at least short term. Furthermore, low V(T) ventilation cannot protect the involved lung, and high PEEP did not significantly alter lung injury over a short time course.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号