首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
An improved ELISA method for the detection of Salmonella typhimurium   总被引:3,自引:2,他引:1  
The applicability of enzyme-linked immunosorbent assay (ELISA) for the detection of salmonellas in foodstuffs was investigated. Several factors affecting the sensitivity of the ELISA, such as the type of protein used for plate post-coating, the method of antibody labelling, and accelerators for antigen-antibody and enzyme-substrate reactions, were studied. Labelling of the antibody with horseradish peroxidase and the use of o -phenylenediamine as substrate in the detection system were demonstrated to be most suitable for the enzyme assay.
Based on these findings, an improved ELISA method was developed for the detection of Salmonella typhimurium. The improved technique was able to detect as few as 5×104-105 cell/ml of salmonellas, and about 24 h were required to enrich the bacteria in food samples and to perform the test. With some modifications, the ELISA assay could reach a very high level of sensitivity and provide excellent repro-ducibility.  相似文献   

2.
Viable but non-culturable salmonellas in soil   总被引:4,自引:1,他引:3  
P.E. TURPIN, K.A. MAYCROFT, C.L. ROWLANDS AND E.M.H. WELLINGTON. 1993. An enzyme-linked immunosorbent assay (ELISA) and a microwell fluorescent antibody (FA) direct count method have been developed for the monitoring of salmonellas in soil. Both methods have a minimum detection level of ca 106 cells per gram of soil. The FA direct count method gave a linear recovery for the inoculum range 106–109 cells per gram of soil. When monitored by plate counts the survival of salmonellas was greater in a sterile than in a non-sterile soil. Evidence was found for the production of viable but non-culturable salmonellas in non-sterile soil; plate counts dropped rapidly with time, but FA direct counts and ELISA remained level. The salmonella cells became progressively smaller and rounder with time. Dead salmonella cells introduced into soil rapidly disappeared.  相似文献   

3.
目的建立两种甲型肝炎病毒抗原(HAV-Ag)检测试剂盒,并对其检测效果进行评价。方法生物素标记甲型肝炎病毒抗体(HAV-Ab)与辣根过氧化物酶标记亲和素联合应用建立甲型肝炎病毒抗原BA-ELISA检测法;同时使用辣根过氧化物酶标记HAV-Ab作放大系统建立双抗体夹心甲型肝炎病毒抗原ELISA检测试剂,对比两种检测方法的特异性、灵敏度及实际应用效果。结果用生物素标记甲型肝炎病毒抗体-辣根过氧化物酶标记亲和素作放大系统建立的甲型肝炎病毒抗原BA-ELISA检测法,较双抗体夹心ELISA检测方法灵敏度高1~2个稀释度;两种检测法均对10余种病毒无交叉,P/N值BA-ELISA检测法较高。结论甲型肝炎病毒抗原BA-ELISA检测法是一种灵敏度高,特异性好,方便快捷的检测方法,可广泛应用于甲型肝炎病毒研究及临床检测中。而甲型肝炎病毒抗原双抗体夹心ELISA检测法,检测灵敏度适中,操作简单,更适用于甲肝疫苗生产检定。  相似文献   

4.
The use of microarray-based immunoassay is often limited by its sensitivity. To increase the sensitivities of such an immunoassay, liposome encapsulation was explored. Two different liposome formations and several preparation methods were examined to optimize encapsulation and signal-enhancing efficacy for enzyme-linked immunosorbent assay (ELISA) and antibody array. The signal amplification by liposome encapsulation was demonstrated through a detection for foodborne pathogenic Listeria. In plate-trapped antigen (PTA) ELISA, horseradish peroxidase (HRP)-loaded liposome increased signal 9-fold more than the control. Limits of detection (LODs) of HRP-encapsulated liposome were 6.4×10(5) and 5.5×10(6)CFU/ml in sandwich ELISA and antibody array, respectively. Furthermore, when chromogenic 4-chloro-1-naphthol (4-CN) substrate was used for signal development in the antibody array, the signal could be detected with the naked eye. These results suggest that the liposome encapsulation technique can have great potential for signal amplification and, therefore, for increasing assay sensitivity for various formats of immunoassay, especially microarray-based format.  相似文献   

5.
A sandwich capture ELISA based on a murine monoclonal antibody against a genus-specific epitope in the outer core region of the Salmonella lipopolysaccharide is described for the detection of different common serotypes of salmonellas. Four h broth cultures of seven standard and 24 wild strains of salmonellas were all detected by the capture ELISA while overnight broth cultures of 21 non-salmonella standard strains were all negative. The capture ELISA detected 1 ng/ml of Ra lipopolysaccharide, 10(6)/ml of a smooth wild strain of Salm. typhimurium, and 1120 cells of Salm. heidelberg after enrichment culture for 4 h.  相似文献   

6.
A Salmonella Assay using the Vitek Immunodiagnostic Assay System (VIDAS) was compared with a conventional cultural method (CCM) for the detection of salmonellas in 141 samples of artificially and naturally contaminated foods. There was an overall agreement of 92.9% between the methods. The productivity of the VIDAS Salmonella Assay (VSA) was not improved using an alternative enrichment protocol for the detection of Salmonella in 12 raw meat samples.
The sensitivity and specificity of the VSA was assessed using pure cultures of salmonellas and non-salmonellas. The detection limit was 1.8 times 106 salmonellas ml-1 in M-broth and some Citrobacter freundii strains gave false-positive results.
Using an immunomagnetic separation (IMS) technique and an abbreviated cultural enrichment, the VSA results could be obtained a day earlier than the standard VSA method.  相似文献   

7.
The sensitivity of a newly developed enzyme-linked immunosorbent assay (ELISA) for detection of antibody to K virus was compared with the sensitivities of an immunofluorescence assay (IFA) and a hemagglutination inhibition assay (HIA). Specific pathogen-free BALB/c RIVM mice, 5 weeks old, were inoculated intraperitoneally with a mouse organ suspension containing 10(4.5) TCID50 of K virus per dose. Control animals were inoculated with a control mouse organ suspension. No clinical signs were observed during the 7 weeks they were followed for the development of serum antibody. The ELISA proved to be the most sensitive of the three assays and demonstrated K virus-specific antibodies as early as 3 days after infection.  相似文献   

8.
Nine monoclonal antibodies (MAbs) developed against Plasmodium vivax (Grassi & Feletti) salivary gland sporozoites were evaluated for use in an enzyme-linked immunosorbent assay (ELISA), using sporozoites developed in Anopheles dirus Peyton & Harrison An. gambiae Giles and An.maculatus Theobald. Four of the antibodies were unsuitable due to the low sensitivity of the resulting assays or the requirement for high concentrations of capture antibody. An additional two MAbs were rejected because they resulted in assays with high background absorbance, attributed to self-binding. Of the three remaining MAbs, the use of Navy vivax sporozoite (NVS) 3 resulted in an ELISA with the highest sensitivity and the lowest concentration requirement for capture antibody. Assay sensitivity varied with sporozoite strain indicating possible quantitative epitope heterogeneity. None of the MAbs cross-reacted with the heterologous sporozoites tested by immunofluorescence antibody assay (IFA). The IFA activity was not an indicator of ELISA sensitivity. The use of MAb NVS 3 in a standardized ELISA method resulted in an assay 10 times more sensitive than reported previously for P. vivax sporozoites, with a detection limit of fewer than 100 sporozoites per mosquito.  相似文献   

9.
A monoclonal antibody (3A5) that can recognize thiacloprid was produced, and a linear 8-residue peptide phage library was constructed. Six phage-displayed peptides were isolated from the linear 8-residue peptide phage library and a cyclic 8-residue peptide phage library. A phage enzyme-linked immunosorbent assay (ELISA) was developed to detect thiacloprid using a phage-displayed peptide. Under the optimal conditions, the half-maximal inhibition concentration (IC50) and the limit of detection (IC10) of the developed phage ELISA were 8.3 and 0.7 μg/L, respectively. Compared with the conventional ELISA, the sensitivity was improved more than 3-fold. The cross-reactivity (CR) was less than 0.08% for the tested structural analogues and was regarded as negligible. The recoveries of thiacloprid ranged from 80.3% to 116.3% in environmental and agricultural samples, which conformed to the requirements for residue detection. The amount of thiacloprid detected by phage ELISA in the samples was significantly correlated with that detected by high-performance liquid chromatography. The current study indicates that isolating phage-displayed peptides from phage display libraries is an alternative method for the development of a sensitive immunoassay and that the developed assay is a potentially useful tool for detecting thiacloprid in environmental and agricultural samples.  相似文献   

10.
Highly efficient antibody immobilization is extremely crucial for the development of high-performance polymeric microdevices for enzyme-linked immunosorbent assay (ELISA). In this article, a site-selective tyrosinase (TR)-catalyzed protein A strategy for antibody immobilization was developed to enhance the sensitivity of ELISA in poly-(methyl methacrylate) (PMMA) microchannels for interferon-gamma (IFN-gamma) assay. To effectively immobilize the target antibodies, oxygen plasma was first used to activate the inert PMMA. This is followed by poly(ethyleneimine) (PEI) coating, an amine-containing functional polymer. For comparison, protein A was also immobilized through the commonly used amine-glutaraldehyde (GA) chemistry. Oxygen plasma treatment effectively increased the amount of PEI attachment and subsequent binding efficiency of the primary antibody. The antibody immobilized via TR-catalyzed protein A was able to provide much better specific antigen capture efficiency than GA chemistry due to the optimal spacing and orientation. Consequently, by using this new method, the detection signal and the signal-to-noise ratio of the ELISA immunoassay in microdevices were all significantly improved. In comparison to the standard assay carried out in the 96-well microtiter plate, the treated microchannels exhibited a broader detection range and a shorter detection time. And the detection limit was also decreased to 20 pg/mL, much lower than that obtained in other microdevices.  相似文献   

11.
目的:表达委内瑞拉马脑炎病毒E2重组蛋白,并结合胶体金免疫层析技术建立一种简便检测委内瑞拉马脑炎病毒特异性抗体的方法。方法:利用已经构建的表达E2抗原的工程菌, 用IPTG诱导, 表达蛋白主要以包涵体的形式存在。通过一系列条件的变性、复性、透析,所制抗原用以包被硝酸纤维素膜,利用胶体金标记和免疫层析技术,建立委内瑞拉马脑炎病毒快速检测方法。对该方法的敏感性、特异性和稳定性作出评价。结果:重组工程菌可表达分子质量为 40 kDa的目的蛋白, 纯化后的蛋白质经SDS-PAGE显示纯度达95%以上。建立的检测方法可在20 min内完成检测。对症状相似及近缘的其他病毒进行检测,均无非特异反应。试纸条在37℃下保存2周,检测结果不变。该方法与R&;D公司商品化的ELISA试剂盒灵敏度检测无明显差异;对92份阴性血清进行检测,两种检测方法的符合率为96.7%。结论:重组委内瑞拉马脑炎病毒蛋白产生的包涵体变性复性后生具有良好的重复性和稳定性, 可作为委内瑞拉马脑炎病毒多种检测方法的抗原原料。胶体金免疫层析法具有快速、灵敏、特异、稳定的特点,适用于现场检测。  相似文献   

12.
一种简易的免疫PCR方法的建立   总被引:11,自引:0,他引:11  
免疫PCR为一种高敏感度检测抗原的新技术,操作程序大多沿袭ELISA方法.用戊二醛作连接剂,将蛋白质高效率包被在普通PCR管内壁,使免疫及PCR反应用普通PCR仪得以在管中连贯地进行.实验结果表明,标准曲线的线性关系好,与ELISA方法比较敏感度高出约105.这一改良法的建立,可望促进免疫PCR的普及应用.  相似文献   

13.
AIMS: To improve the sensitivity of a monoclonal antibody (MAb 2F3) based enteropathogenic Escherichia coli (EPEC)/enterohaemorrhagic E. coli (EHEC) serogroup O26-specific sandwich ELISA (sELISA), using a capture/enrichment format of the assay. METHODS AND RESULTS: The sELISA utilized an EPEC/EHEC O26-specific MAb 2F3 as the capture reagent and an E. coli serogroup O26 lipopolysaccharide-specific polyclonal antibody in the development stage. Wells containing faeces test samples from bovine enteritis cases and agar colony sweep cultures from human diarrhoea cases, after a 2-h capture stage, were washed and enrichment of the captured cells was encouraged by addition of tryptone soya broth. After overnight incubation, the contents of each well were transferred to sterile wells and the sELISA completed. Any sELISA positive samples were then subcultured onto blood agar to recover and further characterize the positive cultures. The assay had a sensitivity of 10(3) CFU ml(-1). ELISA positive samples consisted of 21 (4.8%) of the 442 bovine and 19 (3.7%) of the 519 human samples tested, and ELISA positive EPEC/EHEC O26 strains were isolated from 11 and three of these samples respectively. CONCLUSION: The capture/enrichment method improved the sensitivity of a MAb-based sELISA for the detection of EPEC/EHEC O26 strains, and also contributed to an improved isolation rate of the organism from field samples. SIGNIFICANCE AND IMPACT OF THE STUDY: The application of a specific MAb in a capture/enrichment format of the sELISA, provides a prospectively suitable screening method for the detection of pathogenic bacteria from mixed culture samples.  相似文献   

14.
A novel surface treatment method was developed to enhance polymer-based microchannel enzyme-linked immunosorbent assay (ELISA) for Escherichia coli O157:H7 detection. By applying an amine-bearing polymer, poly(ethyleneimine) (PEI), onto poly(methyl methacrylate) (PMMA) surface at pH higher than 11, PEI molecules were covalently attached and their amine groups were introduced to PMMA surface. Zeta potential analysis and X-ray photoelectron spectroscopy (XPS) demonstrated that the alkali condition is preferable for PEI attachment onto the PMMA surface. The amine groups on the PMMA surface were then functionalized with glutaraldehyde, whose aldehyde groups served as the active sites for binding the antibody by forming covalent bonds with the amine groups of the protein molecules. This surface modification greatly improved antibody binding efficiency and the microchannel ELISA for E. coli O157:H7 detection. Compared with untreated PMMA microchannels, approximately 45 times higher signal and 3 times higher signal/noise ratio were achieved with the PEI surface treatment, which also shortened the time required for cells to bind to the microchannel surface to approximately 2 min, much less than that usually required for the same ELISA carried out in 96-well plates. The detection in the microchannel ELISA only required 5-8 cells per sample, which is also better than 15-30 cells required in multi-well plates. With the high sensitivity, short assay time, and small reagent consumption, the microchannel ELISA can be economically used for fast detection of E. coli O157:H7.  相似文献   

15.
Diagnosis of hydatidosis is based on immunodiagnostic methods along with radiological and ultrasound examinations. The objectives of the present study were to develop a specific and simple antigen-based ELISA method for diagnosis of hydatidosis and compare it with antibody detection method. The subjects in this study included 89 patients in the following groups: surgically confirmed hydatidosis patients (35 cases), control with other parasitic diseases (29 cases), and healthy controls (25 cases). Hyperimmune serum was raised against hydatid cyst fluid in rabbits. Anti-hydatid cyst IgG was purified by affinity chromatography using protein A column and labeled with horseradish peroxidase. Collected sera were assessed for hydatid cyst antigens and antibody by ELISA. Circulating hydatid antigen was found in 9 out of 35 patients with surgically confirmed hydatidosis. A sensitivity of 25.7% and a specificity of 98.0% were calculated for the antigen detection assay. Antibody detection by indirect ELISA, using antigen B, showed that 94.2% of patients (33 cases) have anti-hydatid cyst antibodies in their serum while cross reaction was noted in a few of non-hydatidosis patients. A sensitivity of 94.2% and specificity of 81.6% were found for the antibody detection assay. Findings of this study indicated that antibody detection assay is a sensitive approach for diagnosis of hydatid cyst while antigen detection assay might be a useful approach for assessment of the efficacy of treatment especially after removal of the cyst.  相似文献   

16.
A serological typing scheme of Bacillus cereus has been developed by immunochemical analyses of flagellar antigen using an agglutination method. Enzyme-linked immunosorbent assay (ELISA) for the classification of flagellar serotype of Bacillus cereus had greater sensitivity. 10-500 times, than that of agglutination method. The specificity of flagellar antigen and antibody was determined by immunogold electron microscopy and ELISA inhibition assay. Application of ELISA is useful for the detection of the small amounts and many kinds of antigen-antibody reactions.  相似文献   

17.
Hybridomas secreting HBsAg antibodies were obtained by fusing murine myeloma cell line P3-X63-Ag8 to spleen cells of BALB/c mice sensitized with HBsAg. The surface antigen used for immunization of mice was prepared by purification from pooled human plasma specimens. Resulting monoclonal antibodies were detected by the SPRIA method. Clones producing highest anti-HBs titres were used to prepare mouse ascitic fluids. Monoclonal antibodies in ascitic fluid reached a titre of 10(6) to 10(7) at a protein concentration of 1 mg per ml. Two of the prepared monoclonal antibodies, HBS-01 and HBS-02, both belonging to IgG1 subclass of immunoglobulins, were selected for further study in order to assess their potential useability in the commercial ELISA kit. The pI values for HBS-01 ranged from 6.60 to 6.85, for HBS-02 from 5.6 to 6.1. In solid phase ELISA test the use of HBS-01 antibody improved accuracy of the assay by increasing its detection sensitivity for HBsAg subtypes adw and ayw in the reference serum; this sensitivity was evidently much better than that seen with the commercially available rabbit polyclonal anti-HBsAg antibody. The monoclonal antibody HBS-01 is specific to the determinant "a", which makes it suitable for use in ELISA test aimed at HBsAg detection. The antibody HBS-02 showed a markedly better reaction with HBsAg subtype adw than subtype ayw and can thus be used with advantage for their discrimination.  相似文献   

18.
An enzyme-linked immunofiltration assay (ELIFA) and a microtitre plate enzyme-linked immunosorbent assay (ELISA) were developed and compared for their ability to detect staphylococcal enterotoxin B (SEB). The double antibody capture format was used for both assays. Factors which improved the sensitivity of the ELIFA system were (1) addition of casein and thimerosal to the antigen dilution buffer; (2) addition of polyethylene glycol (MW 6000) to the detection and conjugate antibody dilution buffers; and (3) washing with diethanolamine buffer prior to addition of the substrate/chromogen. The ELIFA system had a turnaround time of approximately 1 h and a detection limit of 1 ng/mL of purified SEB. The ELISA had a total turnaround time of 21 h, or 3 h using plates pre-coated overnight with the capture antibody. The detection limit of the ELISA for purified SEB was 0.05 ng/mL. The detection limit of SEB in cheese samples spiked with purified enterotoxin and subjected to a simple extraction procedure was 1 ng/mL and 0.1 ng/mL of extract, with the ELIFA and the ELISA, respectively.  相似文献   

19.
D.CHOI, R.S.W. TSANG AND M.H. NG. 1992. A sandwich capture ELISA based on a murine monoclonal antibody against a genus-specific epitope in the outer core region of the Salmonella lipopolysaccharide is described for the detection of different common serotypes of salmonellas. Four h broth cultures of seven standard and 24 wild strains of salmonellas were all detected by the capture ELISA while overnight broth cultures of 21 non-salmonella standard strains were all negative. The capture ELISA detected 1 ng/ml of Ra lipopolysaccharide, 106/ml of a smooth wild strain of Salm. typhimurium , and 1120 cells of Salm. heidelberg after enrichment culture for 4 h.  相似文献   

20.
Three sandwich-ELISAs, two of which are commercially available (Tecra and Locate), and one developed at the Veterinary Sciences Division, Stormont and a 3-step culture protocol, were compared for the detection of salmonella in 1000 animal specimens. Eight hundred and fifty of these were new submissions and the remainder were frozen portions from specimens previously shown to contain salmonellas by culture. The incidence of ELISA false-negative and false-positive results was highest for the Stormont and Locate kits respectively although the differences in sensitivity and specificity between the three ELISAs was not statistically significant. On 16 occasions all ELISA methods indicated the presence of salmonellas when none were isolated by initial culture, eight of these specimens contained salmonellas when reinvestigated by culture.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号