Analysis of a femoral hip prosthesis designed to reduce stress shielding   总被引:11,自引:0,他引:11  
The natural stress distribution in the femur is significantly altered after total hip arthroplasty (THA). When an implant is introduced, it will carry a portion of the load, causing a reduction of stress in some regions of the remaining bone. This phenomenon is commonly known as stress shielding. In response to the changed mechanical environment the shielded bone will remodel according to Wolff's law, resulting in a loss of bone mass through the biological process called resorption. Resorption can, in turn, cause or contribute to loosening of the prosthesis. The problem is particularly common among younger THA recipients. This study explores the hypothesis that through redesign, a total hip prosthesis can be developed to substantially reduce stress shielding. First, we describe the development of a new femoral hip prosthesis designed to alleviate this problem through a new geometry and system of proximal fixation. A numerical comparison with a conventional intramedullary prosthesis as well as another proximally fixed prosthesis, recently developed by Munting and Verhelpen (1995. Journal of Biomechanics 28(8), 949–961) is presented. The results show that the new design produces a more physiological stress state in the proximal femur.  相似文献   

2.
All hip replacement prostheses alter the load transfer from the hip joint into the femur by changing the mechanical loading of the proximal femur from an externally to an internally loaded system. This alteration of the load transfer causes stress shielding and might lead to severe bone loss, especially with uncemented prostheses. To minimize these effects, load transfer to the femur should occur as proximal as possible. In order to support sufficient primary stability, however, directly post operative (PO) distal stabilization is reasonable. Consequently, the prostheses have to alter its mechanical characteristics after implantation. This concept is referred to as load-shift concept. Primary stability during the early PO state is provided by a prosthesis shaft, which is widened at the tip by a biodegradable pin. After resorption of the pin load transfer occurs no longer distally. The objective of this study was the numerical evaluation of the load-shift concept. The analysis was performed with a finite element model. Three-dimensional non-linear dynamic gait analyses data were used to evaluate whether the load transfer during walking can be altered effectively by insertion and resorption of a distal pin. Directly PO 38% of the transverse load is transferred through the prosthesis shaft and micromotion of the proximal prostheses tip is below 55 microm. After resorption of the pin, no transverse loads are transferred through the prosthesis shaft. Therefore, the loading of the proximal bone tissue is far more pronounced than in the case of a standard prosthesis, demonstrating the feasibility of the load-shift concept. A balanced degradation of the pin simultaneously with the ingrowth of the prosthesis is expected to reduce hip replacement complications.  相似文献   

3.
Stress shielding is a biomechanical phenomenon causing adaptive changes in bone strength and stiffness around metallic implants, which potentially lead to implant loosening. Accordingly, there is a need for standard, objective engineering measures of the “stress shielding” performances of an implant that can be employed in the process of computer-aided implant design. To provide and test such measures, we developed hierarchical computational models of adaptation of the trabecular microarchitecture at different sites in the proximal femur, in response to insertion of orthopaedic screws and in response to hypothetical reductions in hip joint and gluteal muscle forces. By identifying similar bone adaptation outcomes from the two scenarios, we were able to quantify the stress shielding caused by screws in terms of analogous hypothetical reductions in hip joint and gluteal muscle forces. Specifically, we developed planar lattice models of trabecular microstructures at five regions of interest (ROI) in the proximal femur. The homeostatic and abnormal loading conditions for the lattices were determined from a finite element model of the femur at the continuum scale and fed to an iterative algorithm simulating the adaptation of each lattice to these loads. When screws were inserted to the femur model, maximal simulated bone loss (17% decrease in apparent density, 10% decrease in thickness of trabeculae) was at the greater trochanter and this effect was equivalent to the effect of 50% reduction in gluteal force and normal hip joint force. We conclude that stress shielding performances can be quantified for different screw designs using model-predicted hypothetical musculoskeletal load fractions that would cause a similar pattern and extent of bone loss to that caused by the implants.  相似文献   

4.
Stress shielding is a biomechanical phenomenon causing adaptive changes in bone strength and stiffness around metallic implants, which potentially lead to implant loosening. Accordingly, there is a need for standard, objective engineering measures of the "stress shielding" performances of an implant that can be employed in the process of computer-aided implant design. To provide and test such measures, we developed hierarchical computational models of adaptation of the trabecular microarchitecture at different sites in the proximal femur, in response to insertion of orthopaedic screws and in response to hypothetical reductions in hip joint and gluteal muscle forces. By identifying similar bone adaptation outcomes from the two scenarios, we were able to quantify the stress shielding caused by screws in terms of analogous hypothetical reductions in hip joint and gluteal muscle forces. Specifically, we developed planar lattice models of trabecular microstructures at five regions of interest (ROI) in the proximal femur. The homeostatic and abnormal loading conditions for the lattices were determined from a finite element model of the femur at the continuum scale and fed to an iterative algorithm simulating the adaptation of each lattice to these loads. When screws were inserted to the femur model, maximal simulated bone loss (17% decrease in apparent density, 10% decrease in thickness of trabeculae) was at the greater trochanter and this effect was equivalent to the effect of 50% reduction in gluteal force and normal hip joint force. We conclude that stress shielding performances can be quantified for different screw designs using model-predicted hypothetical musculoskeletal load fractions that would cause a similar pattern and extent of bone loss to that caused by the implants.  相似文献   

5.
目的:通过三维有限元分析方法来观察并比较3种不同弹性模量钛合金股骨假体在羊股骨置换模型中von-Mises应力分布的情况。方法:采用64排螺旋CT对一健康成年羊的下肢股骨进行全长的CT扫描,扫描层厚为0.5 mm,扫描所得的数据存储为DICOM文件。将得到的DICOM文件导入到CT图像分析软件Mimics 10.0,然后利用Mimics 10.0软件来生成股骨的骨质点云数据,再将生成的骨质点云数据导入到Simpleware分析软件,通过机械加工反求中的复杂曲面造型技术建立起精确的三维实体模型。对三维实体模型进行网格划分,确定了髓腔的形状,并根据羊下肢股骨髓腔的形状设计了作者实验用的羊股骨假体模型,然后在ANSYS 12.1软件中进行网格划分。给予加载缓慢行走载荷以及扭转载荷,分析并比较羊股骨以及3种不同弹性模量钛合金股骨假体在股骨置换模型中von-Mises应力分布的情况。结果:在缓慢行走载荷以及扭转载荷条件下,3种不同弹性模量钛合金股骨假体von-Mises应力分布变化趋势一致,假体的柄颈结合部以及假体柄上1/3为应力集中区域。3种不同弹性模量的最大应力集中点均位于柄颈结合部,60 GPa弹性模量的股骨假体植入后假体的最大应力最小(37.8 MPa、29.1 MPa),股骨的最大应力最大(12.6 MPa、24.5 MPa);80 GPa的次之,假体的最大应力(38.4 MPa、33.4 MPa),股骨的最大应力(12.5 MPa、24.5 MPa);110 GPa的股骨假体植入后假体的最大应力最大(38.9 MPa、38.1 MPa),股骨的最大应力最小(12.3 MPa、24.5 MPa)。60 GPa弹性模量的股骨假体植入后的假体最大位移和相对位移均最小(缓慢行走载荷下假体最大位移为0.551 mm、相对位移为0.008 mm,扭转载荷下假体最大位移为0.730 mm、相对位移为0.011 mm)。结论:较低弹性模量的钛合金股骨假体(60 GPa)由于其弹性模量更接近于骨组织的弹性模量,股骨假体与股骨间的"应力遮挡"效应较小,更有利于应力在股骨假体及股骨间的传递,增加了股骨假体的早期稳定性,延长了其临床寿命。  相似文献   

6.
Micromotions at the interface between bone and prosthesis are believed to induce bone resorption and ultimately lead to loosening of the implant. Thus the initial stability achieved by a hip prosthesis is an important factor for the long-term function of the implant. Knowing the biological consequences of the mechanical conditions, it appears to be mandatory to measure the extent of these three-dimensional movements. An in vitro dynamic method for measurement of the micromotion of the femoral component of hip prostheses has been developed. Tests in cemented prostheses have confirmed that the use of cement reduces sinkage and rotation manyfold and have yielded reference values for stability. Comparison with two types of cementless prostheses has shown that certain cementless implants may achieve stability comparable to cemented ones in some load directions.  相似文献   

7.
Morsellised bone impaction is used in joint prosthesis revision surgery to repair structural damage to the periarticular bone stock. The initial stiffness of the impacted bone is crucial for the survival of the revised hip joint. Impaction of morsellised bone in a femoral canal can cause fractures that may induce implant loosening in both femur and acetabulum. Alternative techniques to increase stiffness can therefore be of major interest. In this study we analyse whether applying a constant pressure during impaction can increase the stiffness of the morsellised bone. We constructed bone pellets by impaction with and without applying a constant pressure. The constrained stiffness and coefficient of secondary strain were determined by unidirectional load testing after construction of the pellets. A significant increase in constrained stiffness (P < 0.001) from 3.9 to 5.5 MPa and a decrease in the coefficient of secondary strain (P < 0.001) from 1.1 to 0.5 were found.  相似文献   

8.
In this work, a new model for internal anisotropic bone remodelling is applied to the study of the remodelling behaviour of the proximal femur before and after total hip replacement (THR). This model considers bone remodelling under the scope of a general damage-repair theory following the principles of continuum damage mechanics. A "damage-repair" tensor is defined in terms of the apparent density and Cowin's "fabric tensor", respectively, associated with porosity and directionality of the trabeculae. The different elements of a thermodynamically consistent damage theory are established, including resorption and apposition criteria, evolution law and rate of remodelling. All of these elements were introduced and discussed in detail in a previous paper (García, J. M., Martinez, M. A., Doblaré, M., 2001. An anisotrophic internal-external bone adaptation model based on a combination of CAO and continuum damage mechanics technologies. Computer Methods in Biomechanics and Biomedical Engineering 4(4), 355-378.), including the definition of the proposed mechanical stimulus and the qualitative properties of the model. In this paper, the fundamentals of the proposed model are briefly reviewed and the computational aspects of its implementation are discussed. This model is then applied to the analysis of the remodelling behaviour of the intact femur obtaining densities and mass principal values and directions very close to the experimental data. The second application involved the proximal femoral extremity after THR and the inclusion of an Exeter prosthesis. As a result of the simulation process, some well-known features previously detected in medical clinics were recovered, such as the stress yielding effect in the proximal part of the implant or the enlargement of the cortical layer at the distal part of the implant. With respect to the anisotropic properties, bone microstructure and local stiffness are known to tend to align with the stress principal directions. This experimental fact is mathematically proved in the framework of this remodelling model and clearly shown in the results corresponding to the intact femur. After THR the degree of anisotropy decreases tending, specifically in the proximal femur, to a more isotropic behaviour.  相似文献   

9.
Stress shielding of the femur is known to be a principal factor in aseptic loosening of hip replacements. This paper considers the use of a hollow stemmed hip implant for reducing the effects of stress shielding, while maintaining acceptably low levels of stress in the cement. Using finite element modelling, the stresses in the proximal femur using different shapes of hollow stem were compared with those produced using comparable sizes of solid stem with different values of elastic modulus. A reduction in stress shielding could be achieved with a hollow stem. A cylindrical hollow stem design was then optimised in order to control the maximum allowable stress in the cement, the minimum allowable stresses in the bone, and a combination of the two. The resulting stems achieved an increase in proximal bone stress of about 15% for the first case and 32% for a model using high strength cement, compared with solid stems of the same nominal outside diameter. The gains of these theoretically optimised designs dropped off rapidly further down the stem. Linearly tapered hollow stems reached a 22% gain, which could be a good compromise between acceptable cement stresses and ease of manufacture.  相似文献   

10.
Due to the presence of the stiff prosthetic stem fitted in the medullary canal during total his replacement, the surrounding cortex of the femur changes its density over time. This bone remodelling takes place with every type of total hip prosthesis; however, its intensity may vary between prostheses and patients. In the worst cases this process can lead to the late failure of the implant. To monitor such bone density evolution, we are developing a tailored Computer-aided Densitometric Image Analysis system (the major part of this our system uses an 8-bit commercial hardware with 256 levels of grey). The equivalent dynamic range of an X-ray picture is about 10 bits. In this paper we present a method to overcome these hardware limitations by improving the software. Using a double-exposure acquisition it is possible to build a 9-bit image that is good enough for most applications involving bone density measurement.  相似文献   

11.
Hip resurfacing arthroplasty is an alternative to traditional hip replacement that can conserve proximal bone stock and has gained popularity but bone resorption may limit implant survival and remains a clinical concern. The goal of this study was to analyze bone remodelling patterns around an uncemented resurfacing implant and the influence of ingrowth regions on resorption. A computed tomography-derived finite element model of a proximal femur with a virtually implanted resurfacing component was simulated under peak walking loads. Bone ingrowth was simulated by six interface conditions: fully bonded; fully friction; bonded cap with friction stem; a small bonded region at the stem-cup intersection with the remaining surface friction; fully frictional, except for a bonded band along the distal end of the cap and superior half of the cap bonded with the rest frictional. Interface condition had a large influence on remodelling patterns. Bone resorption was minimized when no ingrowth occurred at the bone-implant interface. Bonding only the superior half of the cap increased bone resorption slightly but allowed for a large ingrowth region to improve secondary stability.  相似文献   

12.
Revision surgeries of total hip arthroplasty are often caused by a deficient structural compatibility of the implant. Two main culprits, among others, are bone-implant interface instability and bone resorption. To address these issues, in this paper we propose a novel type of implant, which, in contrast to current hip replacement implants made of either a fully solid or a foam material, consists of a lattice microstructure with nonhomogeneous distribution of material properties. A methodology based on multiscale mechanics and design optimization is introduced to synthesize a graded cellular implant that can minimize concurrently bone resorption and implant interface failure. The procedure is applied to the design of a 2D left implanted femur with optimized gradients of relative density. To assess the manufacturability of the graded cellular microstructure, a proof-of-concept is fabricated by using rapid prototyping. The results from the analysis are used to compare the optimized cellular implant with a fully dense titanium implant and a homogeneous foam implant with a relative density of 50%. The bone resorption and the maximum value of interface stress of the cellular implant are found to be over 70% and 50% less than the titanium implant while being 53% and 65% less than the foam implant.  相似文献   

13.
The objective of this paper is to identify the effects of materials of cementless femoral stem on the functional adaptive behaviors of bone.The remodeling behaviors of a two-dimensional simplified model of cementless hip prosthesis with stiff stem,flexible 'iso-elastic' stem,one-dimensional Functionally Graded Material (FGM) stem and two-dimensional FGM stem for the period of four years after prosthesis replacement were quantified by incorporating the bone remodeling algorithm with finite element analysis.The distributions of bone density,von Mises stress,and interface shear stress were obtained.The results show that two-dimensional FGM stem may produce more mechanical stimuli and more uniform interface shear stress compared with the stems made of other materials,thus the host bone is well preserved.Accordingly,the two-dimensional FGM stem is an appropriate femoral implant from a biomechanical point of view.The numerical simulation in this paper can provide a quantitative computational paradigm for the changes of bone morphology caused by implants,which can help to improve the design of implant to reduce stress shielding and the risk of bone-prosthesis interface failure.  相似文献   

14.
15.
Hip resurfacing demonstrates good survivorship as a treatment for young patients with osteoarthritis, but occasional implant loosening failures occur. On the femoral side there is radiographic evidence suggesting that the implant stem bears load, which is thought to lead to proximal stress shielding and adaptive bone remodelling. Previous attempts aimed at reproducing clinically observed bone adaptations in response to the implant have not recreated the full set of common radiographic changes, so a modified bone adaptation algorithm was developed in an attempt to replicate more closely the effects of the prosthesis on the host bone. The algorithm features combined implant–bone interface healing and continuum bone remodelling. It was observed that remodelling simulations that accounted for progressive gap filling at the implant–bone interface predicted the closest periprosthetic bone density changes to clinical X-rays and DEXA data. This model may contribute to improved understanding of clinical failure mechanisms with traditional hip resurfacing designs and enable more detailed pre-clinical analysis of new designs.  相似文献   

16.
In vitro pre-clinical tests of hip prostheses have not yet been developed to the extent that inferior prostheses can be 'screened-out' prior to animal or clinical trials. This paper reports the experimental part of a project to develop a pre-clinical testing platform for cemented femoral hip implants. It is based on the clinical observation (K?rrholm et al. JBJS, 76B (1994) 912-916) that higher subsidence (distal migration) correlates with early revision of hip prostheses. A protocol to measure the relative movement between implant and bone was designed to test whether or not such a measurement, if made in a laboratory, could discriminate between hip prostheses. The protocol was applied to the Lubinus SPII prosthesis (W. Link, Germany) and a Müller Curved Stem (JRI Ltd., UK)-these prostheses were chosen because they are known to have different loosening rates in vivo. Five prostheses of each design were tested. The migration, the rate-of-migration, and the inducible displacement of each prosthesis was recorded over two million cycles of loading.For each implant, rapid initial migration was found, followed by a period of steady-state migration. In the majority of cases, the prostheses migrated medially, distally and posteriorly. On average, the Lubinus migrated less than the Müller in all directions. The average Lubinus migration was less than half that of the Müller, and this difference was significant at a level of p=0.05. Inducible displacement was greater for the Müller compared to the Lubinus. Furthermore, the inducible displacement decreased over time for the majority of Lubinus prostheses whereas it increased over time for the majority of the Müller prostheses leading to the conclusion that a rapid pre-clinical test based on measurement of inducible displacement may be possible.  相似文献   

17.
Uncemented femoral total hip components rely entirely on contact with the prepared femur for their initial fixation. The contact areas and stresses between a straight tubular bone and a metal cylindrical prosthesis 12.5 cm long and 13 mm in diameter were calculated in a finite element model which includes uniform diametral gaps varying from 20 to 500 microns, using transverse loads from 100 to 2000 N. Frictionless three-dimensional contact elements were used between the bone and the prosthesis. Contact stresses were high and irregular in all cases, and the contact areas were small. Two regions of contact were apparent for lower loads and larger gaps. A third region of contact occurred near the distal tip of the implant at higher loads. This region of contact markedly increased the contact stresses at the distal tip of the prosthesis. A 20 microns overlap between bone and implant was modelled to assess a slight interference fit. The contact stress distribution in this case was markedly different from the stress distribution with a 20 microns diametral gap. The data collectively indicates that gaps of less than 20 microns between bone and implant can substantially change contact stress distributions.  相似文献   

18.
Stress analysis of the cement fixation of orthopaedic implants to bone is frequently carried out using finite element analysis. However the stress distribution in the cement layer is usually intricate, and it is difficult to report it in a way that facilitates comparison of implants for pre-clinical testing. To study this problem, and make recommendations for stress reporting, a finite element analysis of a hip prosthesis implanted into a synthetic composite femur is developed. Three cases are analyzed: a fully bonded implant, a debonded implant, and a debonded implant where the cement is removed distal to the stem tip. In addition to peak stresses, and contour and vector plots, a stressed volume and probability-of-failure analysis is reported. It is predicted that the peak stress is highest for the debonded stem, and that removal of the distal cement more than halves this peak stress. This would suggest that omission of the distal cement is good for polished prostheses (as practiced for the Exeter design). However, if the percentage of cement stressed above a certain threshold (say 3 MPa) is considered, then the removal of distal cement is shown to be disadvantageous because a higher volume of cement is stressed to above the threshold. Vector plots clearly demonstrate the different load transfer for bonded and debonded prostheses: A bonded stem generates maximum tensile stresses in the longitudinal direction, whereas a debonded stem generates most tensile stresses in the hoop direction, except near the tip where tensile longitudinal stresses occur due to subsidence of the stem. Removal of the cement distal to the tip allows greater subsidence but alleviates these large stresses at the tip, albeit at the expense of increased hoop stresses throughout the mantle. It is concluded that a thorough analysis of cemented implants should not report peak stress, which can be misleading, but rather stressed volume, and that vector plots should be reported if a precise analysis of the load transfer mechanism is required.  相似文献   

19.
The responsiveness of bone to mechanical stimuli changes throughout life, with adaptive potential generally declining after skeletal maturity is reached. This has led some to question the importance of bone functional adaptation in the determination of the structural and material properties of the adult skeleton. A better understanding of age-specific differences in bone response to mechanical loads is essential to interpretations of long bone adaptation. The purpose of this study is to examine how the altered mechanical loading environment and cortical bone loss associated with total hip arthroplasty affects the structural and biomechanical properties of adult bone at the mid-shaft femur. Femoral cross sections from seven individuals who had undergone unilateral total hip arthroplasty were analyzed, with intact, contralateral femora serving as an approximate internal control. A comparative sample of individuals without hip prostheses was also included in the analysis. Results showed a decrease in cortical area in femora with prostheses, primarily through bone loss at the endosteal envelope; however, an increase in total cross-sectional area and maintenance of the parameters of bone strength, I(x), I(y), and J, were observed. No detectable differences were found between femora of individuals without prostheses. We interpret these findings as an adaptive response to increased strains caused by loading a bone previously diminished in mass due to insertion of femoral prosthesis. These results suggest that bone accrued through periosteal apposition may serve as an important means by which adult bone can functional adapt to changes in mechanical loading despite limitations associated with senescence.  相似文献   

20.
Acetabular cup loosening is a late failure mode of total hip replacements, and peri-prosthetic bone deterioration may promote earlier failure. Preservation of supporting bone quality is a goal for implant design and materials selection, to avoid stress shielding and bone resorption. Advanced polymer composite materials have closer stiffness to bone than metals, ceramics or polymers, and have been hypothesised to promote less adverse bone adaptation. Computer simulations have supported this hypothesis, and the present study aimed to verify this experimentally.A composite hemi-pelvis was implanted with Cobalt Chromium (CoCr), polyethylene (UHMWPE) and MOTIS®carbon-fibre-reinforced polyether etherketone (CFR-PEEK) acetabular cups. In each case, load was applied to the implanted pelvis and Digital Image Correlation (DIC) was used for surface strain measurement. The test was repeated for an intact hemi-pelvis. Trends in implanted vs. intact bone principal strains were inspected to assess the average principal strain magnitude change, allowing comparison of the potential bone responses to implantation with the three cups.The CFR-PEEK cup was observed to produce the closest bone strain to the intact hip in the main load path, the superior peri-acetabular cortex (+12% on average, R2=0.84), in comparison to CoCr (+40%, R2=0.91) and UHWMPE cups (?26%, R2=0.94). Clinical observations have indicated that increased periacetabular cortex loading may result in reduced polar cancellous bone loading, leading to longer term losses in periprosthetic bone mineral density. This study provides experimental evidence to verify previous computational studies, indicating that cups produced using materials with stiffness closer to cortical bone recreate physiological cortical bone strains more closely and could, therefore, potentially promote less adverse bone adaptation than stiffer press-fitted implants in current use.  相似文献   