首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The deposition of manganese in a water distribution system with manganese-related "dirty water" problems was studied over a 1-year period. Four monitoring laboratories with Robbins biofilm sampling devices fitted to the water mains were used to correlate the relationship among manganese deposition, the level of manganese in the water, and the chlorination conditions. Manganese deposition occurred by both chemical and microbial processes. Chemical deposition occurred when Mn(II) not removed during water treatment penetrated the filters and entered the distribution system, where it was oxidized by chlorine and chlorine dioxide used for disinfection. Microbial deposition occurred in areas with insufficient chlorination to control the growth of manganese-depositing biofilm. At 0.05 mg of Mn(II) per liter, the chemical deposition rate was much greater than microbial deposition. Significant deposition occurred at 0.03 mg of manganese per liter, and dirty water complaints were not eliminated until manganese levels were continuously less than 0.02 mg/liter and chlorination levels were greater than 0.2 mg/liter. A guideline level of 0.01 mg of manganese per liter is recommended.  相似文献   

2.
A direct viable counting method was used to rapidly assess the effectiveness of chlorination of biofilms on rapid sand filter gravel. A total of 50% of the cells were nutrient responsive after exposure to 0.5 mg of chlorine per liter, while this value was 25% after exposure to 25 mg of chlorine per liter. A large variation was seen in the numbers of nutrient-responsive cells on different rocks. More cells attached to the sandblasted side of marbles than to the smooth side, but there was no difference in eight of nine cases in the proportion of survival to chlorination between the two different sides. The effectiveness of chlorination appeared to be influenced by the species of bacterium in the biofilm.  相似文献   

3.
A direct viable counting method was used to rapidly assess the effectiveness of chlorination of biofilms on rapid sand filter gravel. A total of 50% of the cells were nutrient responsive after exposure to 0.5 mg of chlorine per liter, while this value was 25% after exposure to 25 mg of chlorine per liter. A large variation was seen in the numbers of nutrient-responsive cells on different rocks. More cells attached to the sandblasted side of marbles than to the smooth side, but there was no difference in eight of nine cases in the proportion of survival to chlorination between the two different sides. The effectiveness of chlorination appeared to be influenced by the species of bacterium in the biofilm.  相似文献   

4.
Ginige MP  Wylie J  Plumb J 《Biofouling》2011,27(2):151-163
Although health risk due to discoloured water is minimal, such water continues to be the source of one of the major complaints received by most water utilities in Australia. Elevated levels of iron (Fe) and/or manganese (Mn) in bulk water are associated with discoloured water incidents. The accumulation of these two elements in distribution systems is believed to be one of the main causes for such elevated levels. An investigation into the contribution of pipe wall biofilms towards Fe and Mn deposition, and discoloured water events is reported in this study. Eight laboratory-scale reactors were operated to test four different conditions in duplicate. Four reactors were exposed to low Fe (0.05 mg l(-1)) and Mn (0.02 mg l(-1)) concentrations and the remaining four were exposed to a higher (0.3 and 0.4 mg l(-1) for Fe and Mn, respectively) concentration. Two of the four reactors which received low and high Fe and Mn concentrations were chlorinated (3.0 mg l(-1) of chlorine). The biological activity (measured in terms of ATP) on the glass rings in these reactors was very low (~1.5 ng cm(-2) ring). Higher concentrations of Fe and Mn in bulk water and active biofilms resulted in increased deposition of Fe and Mn on the glass rings. Moreover, with an increase in biological activity, an increase in Fe and Mn deposition was observed. The observations in the laboratory-scale experiments were in line with the results of field observations that were carried out using biofilm monitors. The field data additionally demonstrated the effect of seasons, where increased biofilm activities observed on pipe wall biofilms during late summer and early autumn were found to be associated with increased deposition of Fe and Mn. In contrast, during the cooler months, biofilm activities were a magnitude lower and the deposited metal concentrations were also significantly less (ie a drop of 68% for Fe and 86% for Mn). Based on the laboratory-scale investigations, detachment of pipe wall biofilms due to cell death or flow dynamics could release the entrapped Fe and Mn into the bulk water, which could lead to a discoloured water event. Hence, managing biofilm growth on drinking water pipelines should be considered by water utilities to minimize accumulation of Fe and Mn in distribution networks.  相似文献   

5.
Factors Influencing the Effectiveness of Swimming Pool Bactericides   总被引:6,自引:3,他引:3       下载免费PDF全文
Techniques for culturing, harvesting, and testing bacteria to evaluate bactericidal chemicals for swimming pools are described. Concentrations of 25, 50, and 100 mg of the chlorine stabilizer cyanuric acid per liter increased the time required for a 99% kill of Streptococcus faecalis by 0.5 mg of chlorine per liter at pH 7.4 and 20 C from less than 0.25 min without cyanuric acid to 4, 6, and 12 min, respectively. The effect of concentrations of ammonia nitrogen in the range found in swimming pools on the rate of kill of 0.5 mg of chlorine per liter and of chlorine plus cyanuric acid was tested. At concentrations of ammonia nitrogen greater than 0.05 mg per liter, faster rates of kill of S. faecalis were obtained with 100 mg of cyanuric acid per liter plus 0.5 mg of chlorine per liter than with 0.5 mg of chlorine per liter alone. When water samples from four swimming pools with low ammonia levels were used as test media, 0.5 mg of added chlorine per liter killed 99.9% of the added S. faecalis in less than 2 min, but water from a pool with a large number of children required 60 to 180 min of treatment.  相似文献   

6.
Although health risk due to discoloured water is minimal, such water continues to be the source of one of the major complaints received by most water utilities in Australia. Elevated levels of iron (Fe) and/or manganese (Mn) in bulk water are associated with discoloured water incidents. The accumulation of these two elements in distribution systems is believed to be one of the main causes for such elevated levels. An investigation into the contribution of pipe wall biofilms towards Fe and Mn deposition, and discoloured water events is reported in this study. Eight laboratory-scale reactors were operated to test four different conditions in duplicate. Four reactors were exposed to low Fe (0.05?mg?l?1) and Mn (0.02?mg?l?1) concentrations and the remaining four were exposed to a higher (0.3 and 0.4?mg?l?1 for Fe and Mn, respectively) concentration. Two of the four reactors which received low and high Fe and Mn concentrations were chlorinated (3.0?mg?l?1 of chlorine). The biological activity (measured in terms of ATP) on the glass rings in these reactors was very low (~1.5 ng cm?2 ring). Higher concentrations of Fe and Mn in bulk water and active biofilms resulted in increased deposition of Fe and Mn on the glass rings. Moreover, with an increase in biological activity, an increase in Fe and Mn deposition was observed. The observations in the laboratory-scale experiments were in line with the results of field observations that were carried out using biofilm monitors. The field data additionally demonstrated the effect of seasons, where increased biofilm activities observed on pipe wall biofilms during late summer and early autumn were found to be associated with increased deposition of Fe and Mn. In contrast, during the cooler months, biofilm activities were a magnitude lower and the deposited metal concentrations were also significantly less (ie a drop of 68% for Fe and 86% for Mn). Based on the laboratory-scale investigations, detachment of pipe wall biofilms due to cell death or flow dynamics could release the entrapped Fe and Mn into the bulk water, which could lead to a discoloured water event. Hence, managing biofilm growth on drinking water pipelines should be considered by water utilities to minimize accumulation of Fe and Mn in distribution networks.  相似文献   

7.
Chlorination is an effective method to control biofilm formation in enclosed pipelines. To date, very little is known about how to control biofilms at the mesoscale in complex pipelines through chlorination. In this study, the dynamic of microbial communities was examined under different residual chlorine concentrations on the biofilms attached to labyrinth channels for drip irrigation using reclaimed water. The results indicated that the microbial phospholipid fatty acids, extracellular polymeric substances, microbial dynamics, and the ace and Shannon microbial diversity indices showed a gradual decrease after chlorination. However, chlorination increased microbial activity by 0.5–19.2%. The increase in the relative abundances of chloride-resistant bacteria (Acinetobacter and Thermomonas) could lead to a potential risk of chlorine resistance. Thus, keeping a low chlorine concentration (0.83?mg l?1 for 3?h) is effective for controlling biofilm formation in the labyrinth channels.  相似文献   

8.
Bacterial nutrients in drinking water.   总被引:5,自引:5,他引:0       下载免费PDF全文
Regrowth of coliform bacteria in distribution systems has been a problem for a number of water utilities. Efforts to solve the regrowth problem have not been totally successful. The current project, which was conducted at the New Jersey American Water Co.-Swimming River Treatment Plant, showed that the occurrence of coliform bacteria in the distribution system could be associated with rainfall, water temperatures greater than 15 degrees C, total organic carbon levels greater than 2.4 mg/liter, and assimilable organic carbon levels greater than 50 micrograms of acetate carbon equivalents per liter. A multiple linear regression model based on free chlorine residuals present in dead-end sections of the distribution system and temperature predicted 83.8% of the heterotrophic plate count bacterial variation. To limit the growth of coliform bacteria in drinking water, the study concludes that assimilable organic carbon levels should be reduced to less than 50 micrograms/liter.  相似文献   

9.
Bacterial nutrients in drinking water   总被引:29,自引:0,他引:29  
Regrowth of coliform bacteria in distribution systems has been a problem for a number of water utilities. Efforts to solve the regrowth problem have not been totally successful. The current project, which was conducted at the New Jersey American Water Co.-Swimming River Treatment Plant, showed that the occurrence of coliform bacteria in the distribution system could be associated with rainfall, water temperatures greater than 15 degrees C, total organic carbon levels greater than 2.4 mg/liter, and assimilable organic carbon levels greater than 50 micrograms of acetate carbon equivalents per liter. A multiple linear regression model based on free chlorine residuals present in dead-end sections of the distribution system and temperature predicted 83.8% of the heterotrophic plate count bacterial variation. To limit the growth of coliform bacteria in drinking water, the study concludes that assimilable organic carbon levels should be reduced to less than 50 micrograms/liter.  相似文献   

10.
A pilot-scale study was initiated to examine the behavior of viruses pulse injected into a distribution system. The influence of a free-chlorine residual and that of virus preadsorption to clay particles was evaluated by tracing the viruses both in the water flow and after elution from the biofilm. These experiments demonstrated, first, that virus preadsorption on 40 mg of Na-montmorillonite per liter increased the residence time of the viruses within the pilot plant by roughly three times and, second, that preadsorption to clay did not prevent viruses from being inactivated by chlorine. Moreover, with no clay added, a greater amount of viruses was recovered from the biofilm than from the water flow (by a factor of 2 or 10 in the absence or presence of chlorine, respectively), indicating a tendency for virus accumulation within biofilms.  相似文献   

11.
A pilot-scale study was initiated to examine the behavior of viruses pulse injected into a distribution system. The influence of a free-chlorine residual and that of virus preadsorption to clay particles was evaluated by tracing the viruses both in the water flow and after elution from the biofilm. These experiments demonstrated, first, that virus preadsorption on 40 mg of Na-montmorillonite per liter increased the residence time of the viruses within the pilot plant by roughly three times and, second, that preadsorption to clay did not prevent viruses from being inactivated by chlorine. Moreover, with no clay added, a greater amount of viruses was recovered from the biofilm than from the water flow (by a factor of 2 or 10 in the absence or presence of chlorine, respectively), indicating a tendency for virus accumulation within biofilms.  相似文献   

12.
Microbial surface adhesion to surfaces and subsequent biofilm establishment are ubiquitous in drinking water systems, which often contribute to deteriorated water quality. Disinfectants are common agents applied to drinking water controlling microbial propagation, yet the underlying mechanisms of how disinfectants function to regulate microbial activity and thereby biofilm development remains elusive. We experimentally studied the effects of chlorination on extracellular polymeric substance (EPS) production, and its impacts on early-stage biofilm formation in a model drinking water system. Results showed that low-level chlorine (≤ 1.0 mg/L) stimulated microbial EPS (especially of proteins) excretion that favored early-stage biofilm formation. Microbes experiencing higher chlorination (>1.0 mg/L) exhibited clearly suppressed growth associated with reduced EPS release, consequently yielding less biofilm formation. Removal of cell-attached proteins and polysaccharides diminished biofilm formation, which highlighted the critical role of EPS (especially protein components) in biofilm development. A negative correlation between chlorination-mediated microbial protein production and cell surface charge suggested that chlorine disinfection may modify cell surface properties through regulation of microbial EPS excretion and thereby mediate biofilm formation. With these quantitative estimations, this study provides novel insights into how chlorination-mediated EPS excretion shapes early-stage biofilm formation, which is essential for practical functioning of drinking water systems.  相似文献   

13.
Persistence of Bacillus atrophaeus subsp. globigii spores on corroded iron coupons in drinking water was studied using a biofilm annular reactor. Spores were inoculated at 10(6) CFU/ml in the dechlorinated reactor bulk water. The dechlorination allowed for observation of the effects of hydraulic shear and biofilm sloughing on persistence. Approximately 50% of the spores initially adhered to the corroded iron surface were not detected after 1 month. Addition of a stable 10 mg/liter free chlorine residual after 1 month led to a 2-log(10) reduction of adhered B. atrophaeus subsp. globigii, but levels on the coupons quickly stabilized thereafter. Increasing the free chlorine concentration to 25 or 70 mg/liter had no additional effect on inactivation. B. atrophaeus subsp. globigii spores injected in the presence of a typical distribution system chlorine residual (approximately 0.75 mg/liter) resulted in a steady reduction of adhered B. atrophaeus subsp. globigii over 1 month, but levels on the coupons eventually stabilized. Adding elevated chlorine levels (10, 25, and 70 mg/liter) after 1 month had no effect on the rate of inactivation. Decontamination with elevated free chlorine levels immediately after spore injection resulted in a 3-log(10) reduction within 2 weeks, but the rate of inactivation leveled off afterward. This indicates that free chlorine did not reach portions of the corroded iron surface where B. atrophaeus subsp. globigii spores had adhered. B. atrophaeus subsp. globigii spores are capable of persisting for an extended time in the presence of high levels of free chlorine.  相似文献   

14.
Nitrification in chloraminated drinking water can have a number of adverse effects on water quality, including a loss of total chlorine and ammonia-N and an increase in the concentration of heterotrophic plate count bacteria and nitrite. To understand how nitrification develops, a study was conducted to examine the factors that influence the occurrence of ammonia-oxidizing bacteria (AOB) in a chloraminated distribution system. Samples were collected over an 18-month period from a raw-water source, a conventional treatment plant effluent, and two covered, finished-water reservoirs that previously experienced nitrification episodes. Sediment and biofilm samples were collected from the interior wall surfaces of two finished-water pipelines and one of the covered reservoirs. The AOB were enumerated by a most-probable-number technique, and isolates were isolated and identified. The resistance of naturally occurring AOB to chloramines and free chlorine was also examined. The results of the monitoring program indicated that the levels of AOB, identified as members of the genus Nitrosomonas, were seasonally dependent in both source and finished waters, with the highest levels observed in the warm summer months. The concentrations of AOB in the two reservoirs, both of which have floating covers made of synthetic rubber (Hypalon; E.I. du Pont de Nemours & Co., Inc., Wilmington, Del.), had most probable numbers that ranged from less than 0.2 to greater than 300/ml and correlated significantly with temperature and levels of heterotrophic plate count bacteria. No AOB were detected in the chloraminated reservoirs when the water temperature was below 16 to 18 degrees C. The study indicated that nitrifiers occur throughout the chloraminated distribution system. Higher concentrations of AOB were found in the reservoir and pipe sediment materials than in the pipe biofilm samples. The AOB were approximately 13 times more resistant to monochloramine than to free chlorine. After 33 min of exposure to 1.0 mg of monochloramine per liter (pH 8.2, 23 degrees C), 99% of an AOB culture was inactivated. The amounts of this disinfectant that are currently used (1.5 mg/liter at a 3:1 ratio of chlorine to ammonia-N) may be inadequate to control the growth of these organisms in the distribution system.  相似文献   

15.
Inactivation of biofilm bacteria   总被引:18,自引:0,他引:18  
The current project was developed to examine inactivation of biofilm bacteria and to characterize the interaction of biocides with pipe surfaces. Unattached bacteria were quite susceptible to the variety of disinfectants tested. Viable bacterial counts were reduced 99% by exposure to 0.08 mg of hypochlorous acid (pH 7.0) per liter (1 to 2 degrees C) for 1 min. For monochloramine, 94 mg/liter was required to kill 99% of the bacteria within 1 min. These results were consistent with those found by other investigators. Biofilm bacteria grown on the surfaces of granular activated carbon particles, metal coupons, or glass microscope slides were 150 to more than 3,000 times more resistant to hypochlorous acid (free chlorine, pH 7.0) than were unattached cells. In contrast, resistance of biofilm bacteria to monochloramine disinfection ranged from 2- to 100-fold more than that of unattached cells. The results suggested that, relative to inactivation of unattached bacteria, monochloramine was better able to penetrate and kill biofilm bacteria than free chlorine. For free chlorine, the data indicated that transport of the disinfectant into the biofilm was a major rate-limiting factor. Because of this phenomenon, increasing the level of free chlorine did not increase disinfection efficiency. Experiments where equal weights of disinfectants were used suggested that the greater penetrating power of monochloramine compensated for its limited disinfection activity. These studies showed that monochloramine was as effective as free chlorine for inactivation of biofilm bacteria. The research provides important insights into strategies for control of biofilm bacteria.  相似文献   

16.
Inactivation of biofilm bacteria.   总被引:6,自引:14,他引:6       下载免费PDF全文
The current project was developed to examine inactivation of biofilm bacteria and to characterize the interaction of biocides with pipe surfaces. Unattached bacteria were quite susceptible to the variety of disinfectants tested. Viable bacterial counts were reduced 99% by exposure to 0.08 mg of hypochlorous acid (pH 7.0) per liter (1 to 2 degrees C) for 1 min. For monochloramine, 94 mg/liter was required to kill 99% of the bacteria within 1 min. These results were consistent with those found by other investigators. Biofilm bacteria grown on the surfaces of granular activated carbon particles, metal coupons, or glass microscope slides were 150 to more than 3,000 times more resistant to hypochlorous acid (free chlorine, pH 7.0) than were unattached cells. In contrast, resistance of biofilm bacteria to monochloramine disinfection ranged from 2- to 100-fold more than that of unattached cells. The results suggested that, relative to inactivation of unattached bacteria, monochloramine was better able to penetrate and kill biofilm bacteria than free chlorine. For free chlorine, the data indicated that transport of the disinfectant into the biofilm was a major rate-limiting factor. Because of this phenomenon, increasing the level of free chlorine did not increase disinfection efficiency. Experiments where equal weights of disinfectants were used suggested that the greater penetrating power of monochloramine compensated for its limited disinfection activity. These studies showed that monochloramine was as effective as free chlorine for inactivation of biofilm bacteria. The research provides important insights into strategies for control of biofilm bacteria.  相似文献   

17.
Three bacterial strains (Kocuria sp. C714.1, Brevibacterium linens B337.1 and Staphylococcus sciuri CCL101) were grown together on stainless steel and were subjected daily to a commercial alkaline chlorine solution (22 mg l-1 of free chlorine, pH 11) over a period of 4 weeks. After the daily chemical shock, culture madia [1:20 dilution of tryptic soy broth (TSB-YE/20) or diluted whey] was deposited on the biofilms. The chemical shocks led first to a drop in the culturable population, followed by an increase and finally stabilization at around 106-107 CFU cm-2 by day 11 of the experiment. These changes in the microbial population can be attributed to a decreasing susceptibility to the antimicrobial agent with biofilm age, and to the consumption of free chlorine by biofilm exoproteins. The microbial composition appeared to be linked to the free chlorine concentration that depended on exoprotein production. At the end of the experiment, exoprotein production was greater for biofilms grown in TSBYE/20 than in whey. As a consequence, biofilms grown in whey did not neutralize the chlorine and the dominant strain was the one having the highest resistance to chlorine: K. varians. When biofilm were grown in TSBYE/20, chlorine was neutralized and the dominant strain was the one having the highest growth rate: S. sciuri. The presence of chlorine may also explain the distribution of S. sciuri cells as a ring around Kocuria sp. microcolonies. When chlorine was totally consumed by the biofilm during the chemical shock, S. sciuri was no longer grouped around Kocuria sp. microcolonies but was evenly scattered over the substratum as single cells or in small clusters, as it was before any chemical treatment. These findings strongly suggest protection of S. sciuri by Kocuria sp. microcolonies against the chlorinated solution. This phenomenon, added to the low susceptibility phenotype of the biofilm cells, could at least partly explain the survival of microbial cells in an adverse environment.  相似文献   

18.
Persistence of Bacillus atrophaeus subsp. globigii spores on corroded iron coupons in drinking water was studied using a biofilm annular reactor. Spores were inoculated at 106 CFU/ml in the dechlorinated reactor bulk water. The dechlorination allowed for observation of the effects of hydraulic shear and biofilm sloughing on persistence. Approximately 50% of the spores initially adhered to the corroded iron surface were not detected after 1 month. Addition of a stable 10 mg/liter free chlorine residual after 1 month led to a 2-log10 reduction of adhered B. atrophaeus subsp. globigii, but levels on the coupons quickly stabilized thereafter. Increasing the free chlorine concentration to 25 or 70 mg/liter had no additional effect on inactivation. B. atrophaeus subsp. globigii spores injected in the presence of a typical distribution system chlorine residual (~0.75 mg/liter) resulted in a steady reduction of adhered B. atrophaeus subsp. globigii over 1 month, but levels on the coupons eventually stabilized. Adding elevated chlorine levels (10, 25, and 70 mg/liter) after 1 month had no effect on the rate of inactivation. Decontamination with elevated free chlorine levels immediately after spore injection resulted in a 3-log10 reduction within 2 weeks, but the rate of inactivation leveled off afterward. This indicates that free chlorine did not reach portions of the corroded iron surface where B. atrophaeus subsp. globigii spores had adhered. B. atrophaeus subsp. globigii spores are capable of persisting for an extended time in the presence of high levels of free chlorine.  相似文献   

19.
Water disinfection systems utilizing electrolytically generated copper and silver ions (200 and 20, 400 and 40, or 800 and 80 micrograms/liter) and low levels of free chlorine (0.1 to 0.4 mg/liter) were evaluated at room (21 to 23 degrees C) and elevated (39 to 40 degrees C) temperatures in filtered well water (pH 7.3) for their efficacy in inactivating Legionella pneumophila (ATCC 33155). At room temperature, a contact time of at least 24 h was necessary for copper and silver (400 and 40 micrograms/liter) to achieve a 3-log10 reduction in bacterial numbers. As the copper and silver concentration increased to 800 and 80 micrograms/liter, the inactivation rate significantly (P less than or equal to 0.05) increased from K = 2.87 x 10(-3) to K = 7.50 x 10(-3) (log10 reduction per minute). In water systems with and without copper and silver (400 and 40 micrograms/liter), the inactivation rates significantly increased as the free chlorine concentration increased from 0.1 mg/liter (K = 0.397 log10 reduction per min) to 0.4 mg/liter (K = 1.047 log10 reduction per min). Compared to room temperature, no significant differences were observed when 0.2 mg of free chlorine per liter with and without 400 and 40 micrograms of copper and silver per liter was tested at 39 to 40 degrees C. All disinfection systems, regardless of temperature or free chlorine concentration, showed increase inactivation rates when 400 and 40 micrograms of copper and silver per liter was added; however, this trend was significant only at 0.4 mg of free chlorine per liter.  相似文献   

20.
Campylobacter jejuni and closely related organisms are important bacterial causes of acute diarrheal illness in the United States. Both endemic and epidemic infections have been associated with consuming untreated or improperly treated surface water. We compared susceptibility of three C. jejuni strains and Escherichia coli ATCC 11229 with standard procedures used to disinfect water. Inactivation of bacterial preparations with 0.1 mg of chlorine and 1.0 mg of monochloramine per liter was determined at pH 6 and 8 and at 4 and 25 degrees C. Under virtually every condition tested, each of the three C. jejuni strains was more susceptible than the E. coli control strain, with greater than 99% inactivation after 15 min of contact with 1.0 mg of monochloramine per liter or 5 min of contact with 0.1 mg of free chlorine per liter. Results of experiments in which an antibiotic-containing medium was used suggest that a high proportion of the remaining cells were injured. An animal-passaged C. jejuni strain was as susceptible to chlorine disinfection as were laboratory-passaged strains. These results suggest that disinfection procedures commonly used for treatment of drinking water to remove coliform bacteria are adequate to eliminate C. jejuni and further correlate with the absence of outbreaks associated with properly treated water.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏