首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Because of the increasing emphasis placed upon land application as a means of wastewater disposal, it is important to evaluate the influences of different factors upon virus survival in soil. The objective of this study was to measure the effects of various environmental variables on virus persistence. Test samples of soil were placed in vials, and the soil was wetted with suspensions of virus in either distilled water, unchlorinated secondary sewage effluent, or mixtures of effluent and water. The viruses used were coxsackieviruses A9 and B3, echovirus 1, poliovirus 2, rotavirus SA11, and bacteriophages T2 and MS2. The rate of virus inactivation was evaluated statistically with regard to conditions under which the vials were incubated and to the soil characteristics. The factors that were found to influence virus survival were temperature, soil moisture content, presence of aerobic microorganisms, degree of virus adsorption to the soil, soil levels of resin-extractable phosphorus, exchangeable aluminium, and soil pH. Overall, temperature and virus adsorption to soil appeared to be the most important factors affecting virus survival.  相似文献   

2.
Laboratory experiments were performed on four different soils, using 100 cm long columns, to determine the extent of virus movement when wastewater percolated through the soils at various hydraulic flow rates. Unchlorinated secondary sewage effluent seeded with either poliovirus type 1 (strain LSc) or echovirus type 1 (isolate V239) was continuously applied to soil columns for 3 to 4 days at constant flow rates. Water samples were extracted daily from ceramic samplers at various depths of the column for the virus assay. The effectiveness of virus removal from wastewater varied greatly among the different soil types but appeared to be largely related to hydraulic flow rates. At a flow rate of 33 cm/day, Anthony sandy loam removed 99% of seeded poliovirus within the first 7 cm of the column. At flow rates of 300 cm/day and above, Rubicon sand gave the poorest removal of viruses; less than 90% of the seeded viruses were removed by passage of effluent through the entire length of the soil column. By linear regression analyses, the rate of virus removal in soil columns was found to be negatively correlated with the flow of the percolating sewage effluent. There was no significant difference in rate of removal between poliovirus and echovirus in soil columns 87 cm long. The rate of virus removal in the upper 17 cm of the soil column was found to be significantly greater than in the lower depths of the soil column. This study suggests that the flow rate of water through the soil may be the most important factor in predicting the potential of virus movement into the groundwater. Furthermore, the length of the soil column is critical in obtaining useful data to predict virus movement into groundwater.  相似文献   

3.
Effect of soil permeability on virus removal through soil columns.   总被引:2,自引:2,他引:0       下载免费PDF全文
Laboratory experiments were performed on four different soils, using 100 cm long columns, to determine the extent of virus movement when wastewater percolated through the soils at various hydraulic flow rates. Unchlorinated secondary sewage effluent seeded with either poliovirus type 1 (strain LSc) or echovirus type 1 (isolate V239) was continuously applied to soil columns for 3 to 4 days at constant flow rates. Water samples were extracted daily from ceramic samplers at various depths of the column for the virus assay. The effectiveness of virus removal from wastewater varied greatly among the different soil types but appeared to be largely related to hydraulic flow rates. At a flow rate of 33 cm/day, Anthony sandy loam removed 99% of seeded poliovirus within the first 7 cm of the column. At flow rates of 300 cm/day and above, Rubicon sand gave the poorest removal of viruses; less than 90% of the seeded viruses were removed by passage of effluent through the entire length of the soil column. By linear regression analyses, the rate of virus removal in soil columns was found to be negatively correlated with the flow of the percolating sewage effluent. There was no significant difference in rate of removal between poliovirus and echovirus in soil columns 87 cm long. The rate of virus removal in the upper 17 cm of the soil column was found to be significantly greater than in the lower depths of the soil column. This study suggests that the flow rate of water through the soil may be the most important factor in predicting the potential of virus movement into the groundwater. Furthermore, the length of the soil column is critical in obtaining useful data to predict virus movement into groundwater.  相似文献   

4.
Adsorption of poliovirus from primary sewage effluent was similar to that from secondary sewage effluent in both batch soil studies and experiments with soil columns 240 cm long. Virus desorption by distilled water was also similar in a soil column that had been flooded with either primary or secondary effluent seeded with virus. These results indicated that absorption of poliovirus from primary effluent and virus movement through the soil were not affected by the higher organic content of primary sewage effluent.  相似文献   

5.
Adsorption of poliovirus from primary sewage effluent was similar to that from secondary sewage effluent in both batch soil studies and experiments with soil columns 240 cm long. Virus desorption by distilled water was also similar in a soil column that had been flooded with either primary or secondary effluent seeded with virus. These results indicated that absorption of poliovirus from primary effluent and virus movement through the soil were not affected by the higher organic content of primary sewage effluent.  相似文献   

6.
Secondary sewage effluent containing about 3 X 10(4) plaque-forming units of polio virus type 1 (LSc) per ml was passed through columns 250 cm in length packed with calcareous sand from an area in the Salt River bed used for ground-water recharge of secondary sewage effluent. Viruses were not detected in 1-ml samples extracted from the columns below the 160-cm level. However, viruses were detected in 5 of 43 100-ml samples of the column drainage water. Most of the viruses were adsorbed in the top 5 cm of soil. Virus removal was not affected by the infiltration rate, which varied between 15 and 55 cm/day. Flooding a column continuosly for 27 days with the sewage water virus mixture did not saturate the top few centimeters of soil with viruses and did not seem to affect virus movement. Flooding with deionized water caused virus desorption from the soil and increased their movement through the columns. Adding CaCl2 to the deionized water prevented most of the virus desorption. Adding a pulse of deionized water followed by sewage water started a virus front moving through the columns, but the viruses were readsorbed and none was detected in outflow samples. Drying the soil for 1 day between applying the virus and flooding with deionized water greatly reduced desorption, and drying for 5 days prevented desorption. Large reductions (99.99% or more) of virus would be expected after passage of secondary sewage effluent through 250 cm of the calcareous sand similar to that used in our laboratory columns unless heavy rains fell within 1 day after the application of sewage stopped. Such virus movement could be minimized by the proper management of flooding and drying cycles.  相似文献   

7.
Virus movement in soil columns flooded with secondary sewage effluent.   总被引:13,自引:13,他引:0       下载免费PDF全文
Secondary sewage effluent containing about 3 X 10(4) plaque-forming units of polio virus type 1 (LSc) per ml was passed through columns 250 cm in length packed with calcareous sand from an area in the Salt River bed used for ground-water recharge of secondary sewage effluent. Viruses were not detected in 1-ml samples extracted from the columns below the 160-cm level. However, viruses were detected in 5 of 43 100-ml samples of the column drainage water. Most of the viruses were adsorbed in the top 5 cm of soil. Virus removal was not affected by the infiltration rate, which varied between 15 and 55 cm/day. Flooding a column continuosly for 27 days with the sewage water virus mixture did not saturate the top few centimeters of soil with viruses and did not seem to affect virus movement. Flooding with deionized water caused virus desorption from the soil and increased their movement through the columns. Adding CaCl2 to the deionized water prevented most of the virus desorption. Adding a pulse of deionized water followed by sewage water started a virus front moving through the columns, but the viruses were readsorbed and none was detected in outflow samples. Drying the soil for 1 day between applying the virus and flooding with deionized water greatly reduced desorption, and drying for 5 days prevented desorption. Large reductions (99.99% or more) of virus would be expected after passage of secondary sewage effluent through 250 cm of the calcareous sand similar to that used in our laboratory columns unless heavy rains fell within 1 day after the application of sewage stopped. Such virus movement could be minimized by the proper management of flooding and drying cycles.  相似文献   

8.
The adsorption rate of a guanidine-resistant strain of poliovirus LSc 2ab was measured in Long Island soils with in situ field cores (10.1 by 75 cm). The test virus was chosen because it exhibited soil adsorption and elution characteristics of a number of non-polioviruses. After the inoculation of cores with seeded sewage effluent at a 1-cm/h infiltration rate, cores were extracted, fractionated, and analyzed for total plaque-forming units per each 5-cm fraction. The results showed that 77% of the viruses were adsorbed in the first 5 cm of soil. An additional 11% were found in the 5- to 10-cm fraction, and a total of 96% of the viruses were adsorbed by 25 cm. The remaining 4% were uniformly distributed over the next 50 cm of soil, with a minimum of 0.23% in each soil section. Few viruses (< 0.22%) were observed in core filtrates. Analysis of the viral distribution pattern in seeded cores, after an application of a single rinse of either sewage effluent or rainwater, indicated that large-scale viral mobilization was absent. However, localized areas of viral movement were noted in both of the rinsed cores, with the rainwater-rinsed cores exhibiting more expensive movement. All mobilized viruses were resorbed at lower core depths.  相似文献   

9.
Poliovirus survival and movement in a sandy forest soil.   总被引:11,自引:11,他引:0       下载免费PDF全文
Movement of poliovirus I (Chat) through nonsterile core samples of a sandy forest soil was monitored, using several regimens of loading with either dechlorinated final effluent from an operating activated sludge treatment plant or distilled water. Stimulated cycles of rainfall and effluent applications, resulting in ionic gradients, were shown to affect virus movement. Such studies indicate that poliovirus applied in effluents may move considerable distances through this soil after rainfall. Survival of poliovirus in the soil at 4 and 20 C has been monitored for 84 days. During this period, the capacity of the virus to migrate is unchanged.  相似文献   

10.
Poliovirus survival and movement in a sandy forest soil.   总被引:11,自引:0,他引:11  
Movement of poliovirus I (Chat) through nonsterile core samples of a sandy forest soil was monitored, using several regimens of loading with either dechlorinated final effluent from an operating activated sludge treatment plant or distilled water. Stimulated cycles of rainfall and effluent applications, resulting in ionic gradients, were shown to affect virus movement. Such studies indicate that poliovirus applied in effluents may move considerable distances through this soil after rainfall. Survival of poliovirus in the soil at 4 and 20 C has been monitored for 84 days. During this period, the capacity of the virus to migrate is unchanged.  相似文献   

11.
The adsorption rate of a guanidine-resistant strain of poliovirus LSc 2ab was measured in Long Island soils with in situ field cores (10.1 by 75 cm). The test virus was chosen because it exhibited soil adsorption and elution characteristics of a number of non-polioviruses. After the inoculation of cores with seeded sewage effluent at a 1-cm/h infiltration rate, cores were extracted, fractionated, and analyzed for total plaque-forming units per each 5-cm fraction. The results showed that 77% of the viruses were adsorbed in the first 5 cm of soil. An additional 11% were found in the 5- to 10-cm fraction, and a total of 96% of the viruses were adsorbed by 25 cm. The remaining 4% were uniformly distributed over the next 50 cm of soil, with a minimum of 0.23% in each soil section. Few viruses (< 0.22%) were observed in core filtrates. Analysis of the viral distribution pattern in seeded cores, after an application of a single rinse of either sewage effluent or rainwater, indicated that large-scale viral mobilization was absent. However, localized areas of viral movement were noted in both of the rinsed cores, with the rainwater-rinsed cores exhibiting more expensive movement. All mobilized viruses were resorbed at lower core depths.  相似文献   

12.
The adsorption and elution of a variety of human enteroviruses in a highly permeable, sandy soil was studied by using cores (43 by 125 mm) collected from an operating recharge basin on Long Island. Viruses studied included field and reference strains of polioviruses types 1 and 3 and reference strains of coxsackie virus B3 and echovirus types 1 and 6. Viruses suspended in treated sewage effluent were allowed to percolate through soil cores, and the filtrate was assayed for unadsorbed viruses. To determine the likelihood of desorption and mobilization, soil-bound viruses were subjected to a rinse with either treated sewage effluent or simulated rainwater which reflected the anion, cation, and pH characteristics of a typical northeastern United States rainfall. The results demonstrated that all polioviruses tested, including both reference and field strains, adsorbed extremely well to cores. Adsorption was somewhat reduced when clean, unconditioned soils were used. Soil-bound poliovirus strain LSc was not significantly mobilized by flooding columns with either a sewage effluent or rainwater rinse. One virus was mobilized by both types of rinses. The amount of viruses mobilized by rainwater rinses ranged from 24 to 66%. Variable adsorption-elution results were observed with other enteroviruses. Two guanidine-resistant mutants of poliovirus LSc demonstrated a soil adsorption-elution profile different from that of the parent strain. The data support the conclusion that soil adsorption-elution behavior is strain dependent and that poliovirus, particularly strain LSc, represents an inappropriate model.  相似文献   

13.
AIMS: To assess the effects of soil type and time of the year on survival of the biocontrol inoculant Pseudomonas fluorescens CHA0 under aerobic conditions in lysimeter effluent water. METHODS AND RESULTS: Effluent water was collected at different times from large outdoor lysimeters (2.5 m deep), which contained a well-drained or a poorly-drained cambisol, and inoculated with CHA0. The inoculant was monitored for 175 d by colony counts, total immunofluorescence cell counts and Kogure's viable cell counts. Cell numbers obtained with the three methods were similar. The inoculant declined exponentially in time and its population level varied considerably depending on the time of the year at which effluent water had been collected and soil type in the lysimeter. Positive correlations were found between the number of resident culturable aerobic bacteria and subsequent survival of the inoculant. CONCLUSION: The fluctuations of inoculant survival patterns correlated with differences in biological properties of lysimeter water that were related to soil type and time of the year. SIGNIFICANCE AND IMPACT OF THE STUDY: Results suggest that predictability of the survival of bacterial soil inoculants transported to groundwater level by heavy rainfall may be improved by taking into account key biological properties of the water.  相似文献   

14.
Land disposal of sewage sludge and effluent is becoming a common practice in the United States. The fertilizer content and humus value of such wastes are useful for agricultural purposes, and the recycling of sewage onto the land eliminates many of our stream pollution problems. The potential exists for crops grown in such irrigated soil to be contaminated by viruses that may be present in the sewage. Studies were initiated to determine viral persistence in soil and on crops grown under natural conditions in field plots that had been flooded to a depth of 1 inch (2.54 cm) with poliovirus 1-inoculated sewage wastes. Lettuce and radishes were planted in sludge- or effluent-flooded soil. In one study, the vegetables were planted 1 day before flooding, and in another they were planted 3 days after the plots were flooded. Survival of poliovirus 1 in soil irrigated with inoculated sewage sludge and effluent was determined during two summer growing seasons and one winter period. The longest period of survival was during the winter, when virus was detected after 96 days. During the summer, the longest survival period was 11 days. Poliovirus 1 was recovered from the mature vegetables 23 days after flooding of the plots had ceased. Lettuce and radishes are usually harvested 3 to 4 weeks after planting.  相似文献   

15.
Land disposal of sewage sludge and effluent is becoming a common practice in the United States. The fertilizer content and humus value of such wastes are useful for agricultural purposes, and the recycling of sewage onto the land eliminates many of our stream pollution problems. The potential exists for crops grown in such irrigated soil to be contaminated by viruses that may be present in the sewage. Studies were initiated to determine viral persistence in soil and on crops grown under natural conditions in field plots that had been flooded to a depth of 1 inch (2.54 cm) with poliovirus 1-inoculated sewage wastes. Lettuce and radishes were planted in sludge- or effluent-flooded soil. In one study, the vegetables were planted 1 day before flooding, and in another they were planted 3 days after the plots were flooded. Survival of poliovirus 1 in soil irrigated with inoculated sewage sludge and effluent was determined during two summer growing seasons and one winter period. The longest period of survival was during the winter, when virus was detected after 96 days. During the summer, the longest survival period was 11 days. Poliovirus 1 was recovered from the mature vegetables 23 days after flooding of the plots had ceased. Lettuce and radishes are usually harvested 3 to 4 weeks after planting.  相似文献   

16.
The downward migration through soil of seeded poliovirus type 1 and echovirus type 1 and of naturally occurring enteroviruses during infiltration of sewage effluent through rapid-infiltration basins was investigated. After 5 days of flooding, the amount of seeded poliovirus type 1 that had migrated 5 to 10 cm downward through the soil profile was found to be 11% of that remaining at the initial burial depth. The amount of echovirus type 1 determined to have moved an equal distance was at least 100-fold less. Migration of naturally occurring enteroviruses during infiltration of sewage effluent through soil could not be measured with accuracy because of the possibility of virus survival from previous applications of effluent. The rate of inactivation for seeded poliovirus 1 and echovirus 1 buried in the infiltration basins ranged between 0.04 and 0.15 log10 units per day during the time when the basins were flooded. Inactivation of these same seeded virus types and of indigenous enterovirus populations in the infiltration basins during the drying portion of the sewage application cycle ranged between 0.11 and 0.52 log10 units per day. The rate of virus inactivation was dependent upon the rate of soil moisture loss. These results indicate that drying cycles during the land application of wastewater enhance virus inactivation in the soil.  相似文献   

17.
The downward migration through soil of seeded poliovirus type 1 and echovirus type 1 and of naturally occurring enteroviruses during infiltration of sewage effluent through rapid-infiltration basins was investigated. After 5 days of flooding, the amount of seeded poliovirus type 1 that had migrated 5 to 10 cm downward through the soil profile was found to be 11% of that remaining at the initial burial depth. The amount of echovirus type 1 determined to have moved an equal distance was at least 100-fold less. Migration of naturally occurring enteroviruses during infiltration of sewage effluent through soil could not be measured with accuracy because of the possibility of virus survival from previous applications of effluent. The rate of inactivation for seeded poliovirus 1 and echovirus 1 buried in the infiltration basins ranged between 0.04 and 0.15 log10 units per day during the time when the basins were flooded. Inactivation of these same seeded virus types and of indigenous enterovirus populations in the infiltration basins during the drying portion of the sewage application cycle ranged between 0.11 and 0.52 log10 units per day. The rate of virus inactivation was dependent upon the rate of soil moisture loss. These results indicate that drying cycles during the land application of wastewater enhance virus inactivation in the soil.  相似文献   

18.
Tests on the quantitative adsorption of polyhedra of a cytoplasmic-polyhedrosis virus of Bombyx mori to soil showed an increase in the adsorption of polyhedra with an increase in the amount of soil, but the number of polyhedra adsorbed per unit weight of soil decreased. The number of polyhedra adsorbed to a fixed quantity of soil was in direct proportion to the polyhedron concentration, and the amount of adsorption increased with acidity but decreased with the addition of reagents which masked the polyvalent cations exposed on the surfaces of soil particles. The polyhedra applied to the top of a soil column were detected microscopically within 4 cm from the surface after the equivalent of 1,120 cm depth of water was passed through the column. The polyhedra occurred on the upper surface of the soil column and on the walls of voids formed by random packing of the soil particles.  相似文献   

19.
Two commercially available soil water samplers and a ceramic sampler constructed in our laboratories were evaluated for their ability to recover viruses from both tap water and secondary sewage effluent. The ceramic sampler consistently gave the best recoveries of viruses from water samples. Soil columns containing ceramic samplers at various depths provide a simple method for studying virus transport through sewage-contaminated soils.  相似文献   

20.
R Fayer 《Applied microbiology》1994,60(8):2732-2735
Cryptosporidium parvum oocysts suspended in 0.5 ml of distilled water were pipetted into plastic vials which were inserted into wells in the heated metal block of a thermal DNA cycler. Block temperatures were set at 5 degrees C incremental temperatures from 60 to 100 degrees C. At each temperature setting four vials containing C. parvum oocysts were placed into wells and held for 15 s before time was recorded as zero, and then pairs of vials were removed 1 and 5 min later. Upon removal, all vials were immediately cooled on crushed ice. Also, at each temperature interval one vial containing 0.5 ml of distilled water was placed in a well and a digital thermometer was used to record the actual water temperature at 30-s intervals. Heated oocyst suspensions as well as unheated control suspensions were orally inoculated by gavage into 7- to 10-day-old BALB/c mouse pups to test for infectivity. At 96 h after inoculation the ileum, cecum, and colon from each mouse were removed and prepared for histology. Tissue sections were examined microscopically. Developmental-stage C. parvum was found in all three gut segments from all mice that received oocysts in unheated water and in water that reached temperatures of 54.4, 59.9, and 67.5 degrees C at 1 min when vials were removed from the heat source. C. parvum was also found in the ileum of one of six mice that received oocysts in water that reached a temperature of 59.7 degrees C at 5 min.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号