首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
The mouse preadipocyte 3T3-L1 line is the most useful cell line for the study of adipocytes. Adipocytes secrete adipocytokines, and abnormal adipocytokine production can cause the metabolic syndrome. Although it is important to understand the characteristics of mouse adipocytokine secretion, it is difficult to quantify these products because they are produced in low concentrations. Here, we developed a highly sensitive enzyme-linked immunosorbent assay (ELISA) for detecting the concentrations of mouse adipocytokines, such as TNFα and leptin. In this method, the antigen was sandwiched by using goat- and rabbit-derived polyclonal antibodies, and the fluorescence intensity produced in the reaction with 4-methylumbelliferyl-β-galacto-sidase pyranosidase (MUG) was measured. TNFα and leptin could be measured at concentrations as low as approximately 1 pg/ml. By using our ELISA method, we also measured the concentrations of TNFα and leptin in mouse 3T3-L1 preadipocytes and adipocytes. The differentiation of preadipocytes into adipocytes enhanced TNFα production and secretion and reduced the leptin production. The amount of TNFα produced in the adipocytes was 3.0 ng/mg-protein; this amount was considerably higher than that of leptin.  相似文献   

2.
A competitive enzyme-linked immunosorbent assay (ELISA) has been developed for the enzyme, dihydrofolate reductase. The sensitivity of the assay system approximates 3 ng of immunoreactive enzyme protein which is comparable to the sensitivity achieved in the radioimmunoassay (RIA) for this enzyme. The mean coefficient of variation for within--and between--assay precision was less than 13%. The assay appears to be specific and valid as the concentration of the enzyme is the same whether measured by ELISA or [3H]-methotrexate binding. Since this method, like the RIA, measures the mass concentration of enzyme protein, in conjunction with a [3H]-methotrexate binding assay it will be useful for quantitating functional as well as non-functional immunoreactive forms of the enzyme.  相似文献   

3.
In this study, a highly sensitive capillary-based enzyme-linked immunosorbent assay (ELISA) has been developed for the analysis of picomolar levels of thrombin-cleaved osteopontin (trOPN), a potential biomarker for ischemic stroke, in human plasma. Using a square capillary coated with 8.5 μg/ml anti-human trOPN capture antibody for ELISA, the linear range obtained was 2 to 16 pM trOPN antigen. This concentration range was in the detection window of trOPN antigen in plasma samples. Compared with the conventional microplate-based ELISA, the current capillary technique significantly reduced the amounts of reagent from milliliter to microliter, reduced the analysis time from 8 to 3 h, and had a better sensitivity and detection limit performance from approximately 50 pM down to 2 pM of trOPN antigen. These results indicate that this capillary-based immunoassay is a potential tool for biomarker detection and may be useful in clinical trials and medical diagnostic applications.  相似文献   

4.
A rapid and sensitive screening sandwich enzyme-linked immunosorbent assay (ELISA) was developed for the detection of staphylococcal enterotoxin B (SEB) in cheese by using a highly avid anti-SEB antibody (Ab) as the capture Ab (CAb) and as the biotinylated Ab conjugate. The glutaraldehyde fixation method for the immobilization of CAb on polystyrene dipsticks was superior to the adsorption fixation and the adsorption-glutaraldehyde fixation methods. The glutaraldehyde fixation method resulted in a higher surface-saturating CAb concentration as evaluated by the peroxidase saturation technique and by the ability of the CAb-coated dipstick to discriminate between positive and negative controls (index of discrimination). Of nine blocking agents used alone or in pairs, lysine-human serum albumin, bovine serum albumin, human serum albumin, and gelatin effectively saturated available sites on the CAb-coated dipsticks without causing interference with the antigen-Ab reactions. The addition of 1% polyethylene glycol to the diluent of the biotinylated anti-SEB Ab conjugate improved the detection of SEB. A concentration of 4% polyethylene glycol allowed a 5-min reaction time for the streptavidin-biotin-horseradish peroxidase conjugate. Cheddar cheese homogenate reduced the sensitivity of the SEB assay; however, the sensitivity was restored when 1.6% (wt/vol) of either a nonionic detergent (Mega-9) or two zwitterionic detergents (Zwittergent 3-10 and 3-12 detergent) was added to the diluent. By using the rapid sandwich ELISA, a minimum of 0.5 to 1.0 ng of SEB per ml was detected within 45 min. The whole procedure for the analysis of the cheddar cheese samples was completed within 1 h.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

5.
Vero cell assay for rapid detection of Clostridium perfringens enterotoxin   总被引:1,自引:0,他引:1  
A rapid assay which measured the biological activity of Clostridium perfringens enterotoxin was developed. The method involved the rapid killing of Vero cells by enterotoxin produced by C. perfringens grown in Duncan and Strong sporulation medium. Serial dilutions of toxin were added to Vero cells either in suspension or grown as monolayers in wells of a 96-well cell tissue culture cluster plate. Vital staining of Vero cells with neutral red, followed by extraction of the dye, allowed toxin levels to be determined either visually or by optical density measurements with a micro-ELISA M580 computer program. The toxin produced was confirmed as different from the Vero toxin of Escherichia coli and the alpha and theta toxins of C. perfringens.  相似文献   

6.
A rapid and sensitive screening sandwich enzyme-linked immunosorbent assay (ELISA) was developed for the detection of staphylococcal enterotoxin B (SEB) in cheese by using a highly avid anti-SEB antibody (Ab) as the capture Ab (CAb) and as the biotinylated Ab conjugate. The glutaraldehyde fixation method for the immobilization of CAb on polystyrene dipsticks was superior to the adsorption fixation and the adsorption-glutaraldehyde fixation methods. The glutaraldehyde fixation method resulted in a higher surface-saturating CAb concentration as evaluated by the peroxidase saturation technique and by the ability of the CAb-coated dipstick to discriminate between positive and negative controls (index of discrimination). Of nine blocking agents used alone or in pairs, lysine-human serum albumin, bovine serum albumin, human serum albumin, and gelatin effectively saturated available sites on the CAb-coated dipsticks without causing interference with the antigen-Ab reactions. The addition of 1% polyethylene glycol to the diluent of the biotinylated anti-SEB Ab conjugate improved the detection of SEB. A concentration of 4% polyethylene glycol allowed a 5-min reaction time for the streptavidin-biotin-horseradish peroxidase conjugate. Cheddar cheese homogenate reduced the sensitivity of the SEB assay; however, the sensitivity was restored when 1.6% (wt/vol) of either a nonionic detergent (Mega-9) or two zwitterionic detergents (Zwittergent 3-10 and 3-12 detergent) was added to the diluent. By using the rapid sandwich ELISA, a minimum of 0.5 to 1.0 ng of SEB per ml was detected within 45 min. The whole procedure for the analysis of the cheddar cheese samples was completed within 1 h.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
章先  何珂  黄志伟  单颖  曹统  谢珲  宋厚辉 《菌物学报》2020,39(3):599-609
赭曲霉毒素(ochratoxins)主要是由青霉菌Penicillium和曲霉菌Aspergillus产生的有毒次级代谢产物,常见于发霉或发酵的农产品中,其中赭曲霉毒素A(ochratoxin A,OTA)毒性最强且最为普遍。OTA是粮食作物和饲料的重要污染物,在加工、储存或运输过程中均可产生,具有肾毒性和免疫毒性,可通过蓄积作用发挥毒性效应,对人类和动物健康造成严重威胁。本研究通过将OTA单克隆抗体包被于纳米磁珠(magnetic nanoparticles,MNPs)表面,获得具有免疫活性的磁珠抗体复合物(MNPs-Anti OTA),并制备生物素标记的偶联抗原OTA-BSA-Bio,后续采用链酶亲和素标记的纳米金颗粒(Strep-HRP-AuNPs)催化底物进行信号检测,最终建立了OTA高灵敏检测方法(MNPs-bs-AuNPs-ELISA)。在最优条件下,经计算该方法检测下限(IC10)为0.01ng/mL,检测区间(IC20-IC80)为0.02-0.73ng/mL,半数抑制率(IC50)为0.13ng/mL。与OTA类似物OTB、OTC交叉反应性为4.3%和8.1%,对其他常见真菌毒素AFB1、ZEN、FB1、DON、CIT和PAT均无交叉反应。玉米、面粉和大豆样本中的加标回收率可达85.6%-115.7%,对天然样本中OTA含量的检测结果表明,该方法与LC-MS/MS相关性良好。本研究建立的MNPs-bs-AuNPs-ELISA可满足谷物及饲料样本中OTA的快速、高灵敏度定量检测,成本较低,具有很好的应用前景。  相似文献   

8.
A rapid assay which measured the biological activity of Clostridium perfringens enterotoxin was developed. The method involved the rapid killing of Vero cells by enterotoxin produced by C. perfringens grown in Duncan and Strong sporulation medium. Serial dilutions of toxin were added to Vero cells either in suspension or grown as monolayers in wells of a 96-well cell tissue culture cluster plate. Vital staining of Vero cells with neutral red, followed by extraction of the dye, allowed toxin levels to be determined either visually or by optical density measurements with a micro-ELISA M580 computer program. The toxin produced was confirmed as different from the Vero toxin of Escherichia coli and the alpha and theta toxins of C. perfringens.  相似文献   

9.
10.
11.
G J Marcus  R Durnford 《Steroids》1985,46(6):975-986
A new, enzyme-linked, immunosorbent assay for testosterone is described. The assay uses horseradish peroxidase coupled to testosterone as the tracer and offers the same sensitivity and reliability but greater convenience than radioimmunoassay. The assay is also simpler and more rapidly completed than previously described assays for testosterone.  相似文献   

12.
A two-site enzyme-linked immunosorbent assay for inhibin.   总被引:1,自引:0,他引:1  
The investigation of the role of inhibin in the regulation of fertility is hindered by the lack of a routine, specific assay. The pituitary cell bioassay is time-consuming and the existing RIAs, based on either purified bovine 32-kDa inhibin or synthetic alpha-subunit peptides, are not specific for the biologically active inhibin molecules. We have used monoclonal antibodies, one specific for the N-terminal region of the human inhibin alpha chain, and the other raised to a peptide sequence close to the C-terminal of the human beta A-inhibin chain, to create a two-site sandwich ELISA specific for alpha beta-inhibin molecules. This was used to estimate levels of inhibin in crude bovine and human follicular fluids and fractions concentrated from them. Comparison of the values obtained with the ELISA and those obtained with the pituitary cell bioassay, suggests that the ELISA measures biologically active inhibin. Compared with the peptide-based RIA, the ELISA gave much lower (as little as 100-fold lower) values for the inhibin content of these samples, e.g., bovine follicular fluid 0.375 micrograms/ml (ELISA) compared with 41.0 micrograms/ml (RIA). Such large differences, possibly due to the presence of relatively large amounts of biologically inactive forms of inhibin such as the pro-alpha c or free alpha forms, suggest that those RIAs, which essentially measure the level of alpha-inhibin, considerably overestimate the levels of the active forms of inhibin in the samples and that results obtained using these assays may need reinterpretation.  相似文献   

13.
14.
A double-antibody sandwich, enzyme-linked immunosorbent assay has been developed for phytochrome in Avena sativa L. cv. Saladin. An immunoglobulin fraction of rabbit antiserum raised to 118 kdalton phytochrome was used with alkaline phosphatase as the enzyme label. The assay detected as little as 0.2 ng phytochrome in extracts of dark-grown plant material. No evidence for specific or non-specific measurement of proteins other than phytochrome was found. The assay detected phytochrome in extracts of Avena grown in the light. Dilution curves for light-grown phytochrome extracts had a reduced slope and saturated at a lower level of enzyme activity than those for dark extracts. These differences were not caused by an inhibitor in extracts from light-grown plants. Phytochromes from dark- and light-grown plants may be immunologically different.  相似文献   

15.
Click chemistry is explored as a potential cost-effective and selective immobilization method for the production of an enzyme-linked immunosorbent assay (ELISA). Coatings were formulated containing either a terminal alkyne or a bicyclo[6.1.0]non-4-yne (BCN) chemical handle, and a diagnostic peptide was subsequently immobilized onto these coatings by the copper-catalyzed azide-alkyne 1,3-dipolar cycloaddition (CuAAC) or copper-free strain-promoted azide-alkyne 1,3-dipolar cycloaddition (SPAAC), respectively. The terminal alkyne-containing coating showed high background levels in subsequent ELISA's due to the copper catalyst used in the immobilization step. The BCN-containing coating, however, was successfully employed and presents a cost-effective alternative to existing (strept)avidin-biotin immobilization methods. This technology was illustrated with an ELISA used for the diagnosis of rheumatoid arthritis (RA) but could be easily applied to a wide range of diagnostic tests.  相似文献   

16.
The development of an enzyme-linked immunosorbent assay (ELISA) for uridine 5'-diphospho-N-acetyl-glucosamine: alpha mannoside beta 1----6 N-acetylglucosaminyltransferase (GnT-V) is reported. The assay quantitates the enzymatic conversion of the specific synthetic GnT-V acceptor GlcNAc beta 1----2Man alpha 1----6Man beta-R (5) to the product GlcNAc beta 1----2[GlcNAc-beta 1----6]Man alpha 1----6Man beta-R (6) when these oligosaccharide structures were covalently attached to bovine serum albumin which was then coated on microtiter wells. Conversion of 5 to 6 was detected using a polyclonal antiserum raised against the product 6 and from which antibodies cross-reacting with acceptor 5 had been removed by affinity adsorption. GnT-V activity detected by ELISA was linearly proportional to both enzyme concentration and time under appropriate experimental conditions where 50-300 fmol of product was formed per microtiter well. GnT-V activity could be measured by ELISA in Triton X-100 extracts of hamster kidney acetone powder and in human serum. The twofold increase in GnT-V activity which is known to accompany Rous sarcoma virus transformation of baby hamster kidney cells could also be quantitated using the ELISA.  相似文献   

17.
Abstract The flow cytometric assay method was tested for the cytotoxic activity of Clostridium perfringens enterotoxin (CPE) in culture using mouse mammary carcinoma cell line FM3A stained with propidium iodide (PI). From the results obtained, FM3A cells proved to be susceptible to CPE. A reproducible dose-response curve with FM3A was obtained between crude CPE at 13.9–109 ng/ml and between purified CPE at 40–400 ng/ml, respectively. These findings indicate that non-adherent FM3A is preferable to determine the cytotoxic activity of CPE because it can be used without detachment procedures with trypsinin compared with adherent African monkey kidney cell line (Vero cells). Furthermore, the flow cytometry with non-adherent cell FM3A stained with PI only proved to be a useful method to determine the biological activity of CPE in culture isolates.  相似文献   

18.
The purification procedure of Clostridium perfringens type A enterotoxin has been improved. The cell sonic extract was precipitated twice with ammonium sulfate, first 40% saturated to concentrate the enterotoxin and then 15% saturated. The two precipitations were followed by gel filtration on Sephadex G-100. The enterotoxin appeared to be homogeneous on 7% polyacrylamide gel electrophoresis after this three-step purification procedure, with a recovery of 56% and a 12.3-fold purification. The solubility properties at different pH values, temperatures, and ammonium sulfate concentrations are also given as basis for the purification procedure.  相似文献   

19.
Clostridium botulinum type G toxin was detected and quantified readily with the enzyme-linked immunosorbent assay. With the double-sandwich technique and alkaline phosphatase as the enzyme indicator, C. botulinum toxin type G was detected in quantities equaling those required for one mouse intraperitoneal median lethal dose. The time required for the procedure was approximately 6.5 h, but this requirement could have been reduced to 5.5 h or less with the use of precoated plates stored at -70 degrees C. Cross-reactions did not occur with culture extracts of C. sporogenes of C. botulinum types B, C, D, E, and F. Acidic preparations of C. botulinum type A exhibited nonspecific reactivity. Likewise, 50% of the C. subterminale isolates tested were cross-reactive in the assay. These latter isolates express similar metabolic and physiological characteristics with C. botulinum type G.  相似文献   

20.
A variant of the microtitre GM1-ELISA for Escherichia coli heat-labile enterotoxin was studied. The test was improved by both reducing the assay time from 2 1/2 d to 8 h and by determining the most appropriate GM1 coating concentration. Coating the plates with greater than or equal to 3 micrograms of GM1/ml yielded a maximal sensitivity and ensured a linear relationship between the enterotoxin concentration and the extinction observed when using the final assay-procedure. Thus an optimal accuracy was obtained. This ELISA was 4- to 8-times more sensitive than the Vero cell monolayer assay. The sensitivity of this ELISA and of the chinese hamster ovary cell monolayer assay were identical.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号