首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The pneumoconiosis developing after inhalation of air-borne dusts in the work place depends on the relation between the value of particle deposition in the respiratory tract and the rate of particle clearance from sites of their deposition. For testing the deposition in humans an aerosol of paraffin oil was given to a cohort of healthy persons. The characteristic parameters of the aerosol had been defined. The concentration of particles in 5 channels were measured in both the inhaled and exhaled air samples using the particle counter ROYCO 225. The deposition fraction was calculated from the relation of particle amount in expired air to the amount in inhaled air in each distribution class. In this preliminary report the results comparable with the prediction mathematical curve are discussed.  相似文献   

2.
Theoretical models of particle deposition in the respiratory tract predict high fractional deposition for particles of less than 0.1 micron, but there are few confirming experimental data for those predictions. We have measured the deposition fraction of a nonhygroscopic aerosol in the human respiratory tract. The aerosol had a count mean diameter of 0.044 micron SD of 1.93, as measured with an electrical aerosol analyzer, and was produced from a 0.01% solution of bis(2-ethylhexyl) sebacate using a condensation generator. Subjects inhaled the aerosol using a controlled respiratory pattern of 1 liter tidal volume, 12/min. Deposition was calculated as the difference in concentration between inhaled and exhaled aerosol of five size fractions corrected for system deposition and dead-space constants. Three deposition studies were done on each of five normal male volunteers. Means (+/- SE) for the five size fractions were 0.024 micron, 0.71 +/- 0.06; 0.043 micron, 0.62 +/- 0.06; 0.075 micron, 0.53 +/- 0.05; 0.13 micron, 0.44 +/- 0.04; and 0.24 micron, 0.37 +/- 0.06. These data demonstrate that deposition of inhaled particles in the 0.024- to 0.24-micron size range is high and increases with decreasing size. These observations agree with and validate predictions of mathematical models.  相似文献   

3.
Aerosol delivery is noninvasive and is effective in much lower doses than required for oral administration. Currently, there are several types of therapeutic aerosol delivery systems, including the pressurized metered-dose inhaler, the dry powder inhaler, the medical nebulizer, the solution mist inhaler, and the nasal sprays. Both oral and nasal inhalation routes are used for the delivery of therapeutic aerosols. Following inhalation therapy, only a fraction of the dose reaches the expected target area. Knowledge of the amount of drug actually deposited is essential in designing the delivery system or devices to optimize the delivery efficiency to the targeted region of the respiratory tract. Aerosol deposition mechanisms in the human respiratory tract have been well studied. Prediction of pharmaceutical aerosol deposition using established lung deposition models has limited success primarily because they underestimated oropharyngeal deposition. Recent studies of oropharyngeal deposition of several drug delivery systems identify other factors associated with the delivery system that dominates the transport and deposition of the oropharyngeal region. Computational fluid dynamic simulation of the aerosol transport and deposition in the respiratory tract has provided important insight into these processes. Investigation of nasal spray deposition mechanisms is also discussed.  相似文献   

4.
To relate exposure to adverse health effects, it is necessary to know where particles in the submicron range deposit in the respiratory tract. The possibly higher vulnerability of children requires specific inhalation studies. However, radio-aerosol deposition experiments involving children are rare because of ethical restrictions related to radiation exposure. Thus, an in vivo study was conducted using three baboons as a child respiratory tract model to assess regional deposition patterns (thoracic region vs. extrathoracic region) of radioactive polydisperse aerosols ([d16–d84], equal to [0.15 µm–0.5 µm], [0.25 µm–1 µm], or [1 µm–9 µm]). Results clearly demonstrated that aerosol deposition within the thoracic region and the extrathoraic region varied substantially according to particle size. High deposition in the extrathoracic region was observed for the [1 µm–9 µm] aerosol (72%±17%). The [0.15 µm–0.5 µm] aerosol was associated almost exclusively with thoracic region deposition (84%±4%). Airborne particles in the range of [0.25 µm–1 µm] showed an intermediate deposition pattern, with 49%±8% in the extrathoracic region and 51%±8% in the thoracic region. Finally, comparison of baboon and human inhalation experiments for the [1 µm–9 µm] aerosol showed similar regional deposition, leading to the conclusion that regional deposition is species-independent for this airborne particle sizes.  相似文献   

5.
6.
Studies of aerosol particle deposition in the respiratory tract requires experimental inhalation of artificial model aerosols. The paper formulates some of the most important requirements for the properties of such aerosols. Several suitable fractions were prepared as part of a research project dealing with the use of microporous polymers for diagnostic purposes. 5 fractions of the polymer designated G-gel 60 with the particle size as stated by the manufacturer, ranging from 3 to 7 micron were evaluated using a 16-channel particle dispersity analyzer HIAC/ROYCO MT 3210 with the sensor 1200 and operated by a microprocessor, the equipment being coupled to an APPLE IIe computer. G-gel 60 particles introduced into the aerosol were characterized by the parameters CMAD, MMAD and sg both numerically and graphically. The measurement procedure was found to be very sensitive with respect to all fractions in evaluating the subtile differences between different lot numbers of the aerosol. G-gel 60 fractions characterized both numerically and graphically were compared with the known aerosols from paraffin oil and atmospheric air. The equipment MT 3210 enables prompt determination of the percentages of aerosol particles distribution by size class. The authors conclude that the procedure, both in its numerical and graphical versions, is particularly suitable for the diagnosis of aerosol particles deposition in the respiratory tract, offering a new application for HIAC/ROYCO in the field of medicine. In evaluating atmospheric aerosol in exhaled air, the number of particles was found to be below that in inhaled air, the difference being dependent on the choice of investigation methods. Percentual distribution of deposited particles following one minute ventilation proved to be at its maximum, as regards atmospheric aerosol, in the 0.30-0.50 micron range. The deposition curve was similar to already published curves, being characterized by an S-shaped pattern with maximum deposition in the greater size classes. An analysis of inhaled, exhaled and deposited aerosol suggested that deposited aerosol is more polydisperse and has particles of greater sizes than inhaled aerosol. Investigation of the effect of apnoe on deposition indicated that deposition increased as a function of apnoeic pause.  相似文献   

7.
Aerosol delivery to the airways of the human respiratory tract, followed by absorption, constitutes an alternative route of administration for compounds unsuitable for delivery by conventional oral and parenteral routes. The target for aerosol drug delivery is the airways epithelium, i.e. tracheal, bronchial, bronchiolar and alveolar cells, which become the site of drug deposition. These epithelial layers also serve as a barrier to the penetration of inhaled material. An in vitro model for aerosol deposition and transport across epithelia in the human airways may be a good predictor of in vivo disposition. The present preliminary studies begin an investigation that blends the dynamics of aerosol delivery and the basis of an in vitro simulated lung model to evaluate the transport properties of a series of molecular weight marker compounds across human-derived bronchiolar epithelial cell monolayers. An Andersen viable cascade impactor was used as a delivery apparatus for the deposition of size-segregated particles onto monolayers of small airway epithelial cells and Calu-3 cells. It was shown that these cell layers can withstand placement in the impactor, and that permeability can be tested subsequent to removal from the impactor.  相似文献   

8.
Mathematical models predicting the aerosol deposition in the respiratory tract are reviewed. Data in the literature indicated not only that the air flow in the trachea and major bronchi may not be laminar, but also that the entrance effect of the tube or airway has not been considered. A new approach to a mathematical model of respiratory tract deposition, based on the analogy of the heat and mass transfer, is discussed.  相似文献   

9.
Convective mixing in human respiratory tract: estimates with aerosol boli   总被引:1,自引:0,他引:1  
Convective gas mixing in the respiratory tract of 17 healthy male subjects was studied by an aerosol bolus technique. The monodisperse 1 micron di(2-ethylhexyl)sebacate droplets we used behaved as a nondiffusing gas. As the bolus was inspired to different depths and then expired, we measured the extent to which the bolus spread. We found that the deeper the bolus penetrated into the lungs, the more it became dispersed. The half-width of the expired bolus was a linear function of the volume to which the bolus penetrated at volumetric penetrations of 100-800 cm3. This suggests that convective mixing is not confined to central airways but can also occur in the lung periphery.  相似文献   

10.
The deposition patterns of large-particle microbiological aerosols within the respiratory tract are not well characterized. A novel system (the flow-focusing aerosol generator [FFAG]) which enables the generation of large (>10-μm) aerosol particles containing microorganisms under laboratory conditions was characterized to permit determination of deposition profiles within the murine respiratory tract. Unlike other systems for generating large aerosol particles, the FFAG is compatible with microbiological containment and the inhalational challenge of animals. By use of entrapped Escherichia coli cells, Bacillus atrophaeus spores, or FluoSphere beads, the properties of aerosols generated by the FFAG were compared with the properties of aerosols generated using the commonly available Collison nebulizer, which preferentially generates small (1- to 3-μm) aerosol particles. More entrapped particulates (15.9- to 19.2-fold) were incorporated into 9- to 17-μm particles generated by the FFAG than by the Collison nebulizer. The 1- to 3-μm particles generated by the Collison nebulizer were more likely to contain a particulate than those generated by the FFAG. E. coli cells aerosolized using the FFAG survived better than those aerosolized using the Collison nebulizer. Aerosols generated by the Collison nebulizer and the FFAG preferentially deposited in the lungs and nasal passages of the murine respiratory tract, respectively. However, significant deposition of material also occurred in the gastrointestinal tract after inhalation of both the small (89.7%)- and large (61.5%)-particle aerosols. The aerosols generated by the Collison nebulizer and the FFAG differ with respect to mass distribution, distribution of the entrapped particulates, bacterial survival, and deposition within the murine respiratory tract.  相似文献   

11.
The May spinning top generator was adapted to a modified Henderson tube for producing large aerosol particles (>4 mum) to obtain almost exclusive upper respiratory tract deposition of infectious aerosols in exposed mice. The system was installed in a biological safety cabinet to permit experimentation with pathogens. A novel mechanism utilizing parts from a machinists micrometer and the mechanical stage from a light microscope was developed for the spinning top generator as a means for precisely positioning the liquid feed needle. Aerosol light-scatter properties were continuously analyzed to provide relative measures of particle size distribution and aerosol concentration. When mice were exposed to influenza virus aerosols in which none of the virus was contained in particles with aerodynamic diameters <4 mum, essentially all of the virus was deposited in the upper respiratory tract tissues.  相似文献   

12.
The deposition of aerosol particles in the human lung airways is due to two distinct mechanisms. One is by direct deposition resulting from diffusion, sedimentation and impaction as the aerosol moves in and out of the lung. The other is an indirect mechanism by which particles are transported mechanically from the tidal air to the residential air and eventually captured by the airways due to intrinsic particle motion. This last mechanism is not well understood at present. Using a trumpet airway model constructed from Weibel's data, a two-component theory is developed. In this theory, the particle concentrations in the airways and the alveoli at a given airway depth are considered to be quantitatively different. This difference in concentrations will cause a net mixing between the tidal and residential aerosol as the aerosol is breathed in and out. A distribution parameter is then introduced to account for the distribution of ventilation. The effect of intrinsic particle motion on the aerosol mixing is also included. From this theory, total and regional deposition in the lung at the steady mouth breathing without pause is calculated for several different respiratory cycles. The results agree reasonably well with the experimental data.  相似文献   

13.
A computational model to predict deposition of a wide variety of particulate pollutants in several species of mammals is presented. The model incorporates breathing pattern and detailed anatomical models of the respiratory tract based on extensive morphometric measurements of individual airways. The predicted deposition from this general model is in close agreement with observed deposition of monodisperse aerosols in rats. Particle size and density and respiratory breathing patterns are the critical parameters affecting regional deposition.  相似文献   

14.
Intersubject variability in both peripheral air-space dimensions and breathing pattern [tidal volume (VT) and respiratory frequency (f)] may play a role in determining intersubject variation in the fractional deposition of inhaled particles that primarily deposit in the lung periphery (i.e., distal to conducting airways). In healthy subjects breathing spontaneously at rest, we measured the deposition fraction (DF) of a 2.6-microns monodisperse aerosol by Tyndallometry while simultaneous measurement of VT and f were made. Under these conditions particle deposition occurs primarily in the peripheral air spaces of the lung. As an index of peripheral air-space size, we used measurements of aerosol recovery (RC) as a function of breath-hold time (t) (Gebhart et al. J. Appl. Physiol. 51: 465-476, 1981). In each subject, we measured RC (aerosol expired/aerosol inspired) of a 1.0-micron monodisperse aerosol as a function of breath-hold time for inspiratory capacity breaths of aerosol. The half time (t1/2) (the breath-hold time to reach 50% RC with no breath hold) is proportional to a mean diameter (D) of air spaces filled with aerosol. In the 10 subjects studied, we found a variable DF, range 0.04-0.44 [0.25 +/- 0.12 (SD)]. DF correlated most closely with 1/f, or the period of breathing (r = 0.96, P less than 0.01). There was no significant correlation between DF and t1/2 as an index of peripheral air-space size. In fact there was little deviation in t1/2 in these normal subjects [coefficient of variation (CV) = 0.12].(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
揭示涡结构演化对病毒气溶胶扩散的影响作用,对于有效防治呼吸道疾病具有非常重要的意义.本文运用大涡模拟的方法,对人体在循环呼吸模式下口喉模型内的涡结构演化及气溶胶扩散进行了数值仿真研究,分析了口喉模型内涡结构演化过程以及气溶胶扩散状态.结果表明:受呼吸流涡结构演化的影响,颗粒轨迹主要分布在上气道内涡量集中的区域;受横向涡结构和纵向涡结构的共同影响,部分病毒气溶胶颗粒具备了混合有环状轨迹和波状轨迹的螺旋状轨迹.本研究从微观角度揭示了涡结构演化与气溶胶扩散行为的关系,为深入认识病毒气溶胶上呼吸道传播特点提供了新的途径.  相似文献   

16.
The objective of the study was to develop a scintigraphic method for measurement of airway mucociliary clearance in small laboratory rodents such as the mouse. Previous investigations have characterized the secretory cell types present in the mouse airway, but analysis of the mucus transport system has been limited to in vitro examination of tissue explants or invasive in vivo measures of a single airway, the trachea. Three methods were used to deposit insoluble, radioisotopic colloidal particles: oropharyngeal aspiration, intratracheal instillation, and nose-only aerosol inhalation. The initial distribution of particles within the lower respiratory tract was visualized by gamma-camera, and clearance of particles was followed intermittently over 6 h and at the conclusion, 24 h postdelivery. Subsets of mice underwent lavage for evidence of tissue inflammation, and others were restudied for reproducibility of the methods. The aspiration and instillation methods of delivery led to greater distributions of deposited activity within the lungs, i.e., approximately 60--80% of the total respiratory tract radioactivity, whereas the nose-only aerosol technique attained a distribution of 32% to the lungs. However, the aerosol technique maximized the fraction of particles that cleared the airway over a 24-h period, i.e, deposited onto airway epithelial surfaces and cleared by mucociliary function such that lung retention at 24 h averaged 57% for delivery by aerosol inhalation and > or =80% for the aspiration or intratracheal instillation techniques. Particle delivery methods did not cause lung inflammation/injury with use of inflammatory cells and chemoattractant cytokines as criteria. Scintigraphy can discern particle deposition and clearance from the lower respiratory tract in the mouse, is noninvasive and reproducible, and includes the capability for restudy and lung lavage when time course or chronic treatments are being considered.  相似文献   

17.
Aerosol bolus inspirations were used to assess lung injury in 15 isolated dog lungs exposed to low (0-375 units) or high doses (600-1,200 units) of papain. Effective air space size (EAD) was determined from aerosol deposition during a 5-s breath hold. Convective mixing was assessed by the spreading of the expired bolus with respect to expired volume, quantified by a coefficient of dispersion (CD) equal to the square root of the difference in the variances of the expired and inspired boluses divided by the volumetric penetration of the bolus. After exposure, CD measured with deeply penetrating boluses increased by an average of 2.5% in the low-exposure group (P greater than 0.05) and 28.0% in the high-exposure group (P less than 0.0001). CD measured with shallowly penetrating boluses decreased by 4.3% (P less than 0.0001) in the low-exposure group and increased by an average of 18.3% in the high-exposure group (P less than 0.05). Papain exposure caused EAD to increase in some lungs and decrease in others. For deep bolus penetrations, EAD changed by an average of -0.8% in the low-exposure group (P greater than 0.05) and +21.1% in the high-exposure group (P greater than 0.05). Both EAD and CD appeared to be sensitive to lung injury. However, changes in EAD were less consistent than those in CD, possibly due to changes caused by lung injury in the regional distribution of inspired aerosol.  相似文献   

18.
The data obtained in the experimental study of the humoral factors of local and systemic immunity, as well as the morphofunctional changes of internal organs, after multiple subcutaneous and aerosol immunization with the combined preparation of Proteus, Staphylococcus, Klebsiella pneumoniae and Escherichia coli antigens (preparation nC-4) are presented. The subcutaneous and aerosol administration of preparation nC-4 has been found to induce an increase in the levels of antibodies to all components of the preparation in the blood serum and in respiratory tract secretions. The introduction of the preparation through the respiratory tract resulted in an earlier intensive accumulation of specific antibodies and IgA in respiratory tract secretions. The results of the quantitative cytological study of respiratory tract secretions and the morphofunctional changes of the lymphoid tissue associated with the lungs are indicative of an important role played by cell-mediated immunity factors in the formation of local postvaccinal immunity.  相似文献   

19.
The temperature and humidity of expired air from three adult Merino sheep were measured at air temperatures of 20, 30 and 40 degrees C before and after the animals were shorn. Expired air was apparently always saturated with water vapour. At the higher air temperatures the temperature of expired air was close to deep body temperature; at lower air temperatures, expired air had been significantly cooled, e.g. to 32.3 degrees C in shorn sheep at 20 degrees C air temperature. Expired air was cooler from shorn than from unshorn animals at 20 and 30 degrees C air temperature, possibly due to thermally induced vasomotor changes in the upper respiratory tract. Cooling of expired air would be expected to lead to recovery of some of the water evaporated during inspiration; at 20 degrees C air temperature, this fraction was estimated to be 25% in unshorn sheep and 36% in shorn sheep.  相似文献   

20.
The deposition of ultrafine aerosols in the respiratory tract presents a significant health risk due to the increased cellular-level response that these particles may invoke. However, the effects of geometric simplifications on local and regional nanoparticle depositions remain unknown for the oral airway and throughout the respiratory tract. The objective of this study is to assess the effects of geometric simplifications on diffusional transport and deposition characteristics of inhaled ultrafine aerosols in models of the extrathoracic oral airway. A realistic model of the oral airway with the nasopharynx (NP) included has been constructed based on computed tomography scans of a healthy adult in conjunction with measurements reported in the literature. Three other geometries with descending degrees of physical realism were then constructed with successive geometric simplifications of the realistic model. A validated low Reynolds number k-omega turbulence model was employed to simulate laminar, transitional, and fully turbulent flow regimes for the transport of 1-200 nm particles. Results of this study indicate that the geometric simplifications considered did not significantly affect the total deposition efficiency or maximum local deposition enhancement of nanoparticles. However, particle transport dynamics and the underlying flow characteristics such as separation, turbulence intensity, and secondary motions did show an observable sensitivity to the geometric complexity. The orientation of the upper trachea was shown to be a major factor determining local deposition downstream of the glottis and should be retained in future models of the respiratory tract. In contrast, retaining the NP produced negligible variations in airway dynamics and could be excluded for predominantly oral breathing conditions. Results of this study corroborate the use of existing diffusion correlations based on a circular oral airway model. In comparison to previous studies, an improved correlation for the deposition of nanoparticles was developed based on a wider range of particle sizes and flow rates, which captures the dependence of the Sherwood number on both Reynolds and Schmidt numbers.  相似文献   