首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A high‐yield chemiluminescence (CL) system based on the alkaline permanganate–Rhodamine B reaction was developed for the sensitive determination of fluvoxamine maleate (Flu). Rhodamine B is oxidized by alkaline KMnO4 and a weak CL emission is produced. It was demonstrated that gold nanoparticles greatly enhance this CL emission due to their interaction with Rhodamine B molecules. It is also observed that sodium dodecyl sulfate, an anionic surfactant, can strongly increase this enhancement. In addition, it was demonstrated that a notable decrease in the CL intensity is observed in the presence of Flu. This may be related to Flu oxidation with KMnO4. There is a linear relationship between the decrease in CL intensity and the Flu concentration over a range of 2–300 µg/L. A new simple, rapid and sensitive CL method was developed for the determination of Flu with a detection limit (3s) of 1.35 µg/L. The proposed method was used for the determination of Flu in pharmaceutical and urine samples. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
An enhanced thiosemicarbazide(TSC)–H2O2 chemiluminescence (CL) system was established and proposed as a new analytical method for determination of β‐lactam antibiotics, ampicillin sodium and amoxicillin at microgram levels. The method is based on the inhibition of CL emission accompanying oxidation of TSC by H2O2 in alkaline medium. The effect of anionic, cationic, and non‐ionic surfactants on the CL emission of the system was studied. Both N‐cetyl‐N,N,N‐trimethylammonium bromide (CTMAB) and Triton X‐100, unlike sodium dodecyl sulfate (SDS), reinforced the CL intensity and were efficient to approximately the same level. The effect of the presence of eight non‐aqueous solvents on the CL system was also investigated. Upon addition of both of the non‐ionic surfactant, Triton X‐100, and the non‐aqueous solvent, N,N‐dimethyl formamide (DMF), the intensity of the CL reaction was increased 100‐fold. This method allows the measurement of 25–545 µg amoxicillin, and 35–350 µg ampicillin sodium. The detection limits are 8 µg for amoxicillin and 9 µg for ampicillin sodium. The relative standard deviations of six replicate measurements of 200 µg amoxicillin and 200 µg ampicillin sodium were 1.9 and 2.1%, respectively. The effect of foreign species on the determination of amoxicillin and ampicillin sodium was also examined. The proposed method was successfully applied to the determination of ampicillin sodium and amoxicillin in some pharmaceutical dosage forms. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

3.
Water‐soluble glutathione (GSH)‐capped core/shell CdTe/CdS quantum dots (QDs) were synthesized. In pH 5.4 sodium phosphate buffer medium, the interaction between GSH‐CdTe/CdS QDs and sanguinarine (SA) was investigated by spectroscopic methods, including fluorescence spectroscopy and ultraviolet‐visible absorption spectroscopy. Addition of SA to GSH‐CdTe/CdS QDs results in fluorescence quenching of GSH‐CdTe/CdS QDs. Quenching intensity was in proportion to the concentration of SA in a certain range. Investigation of the quenching mechanism, proved that the fluorescence quenching of GSH‐CdTe/CdS QDs by SA is a result of electron transfer. Based on the quenching of the fluorescence of GSH‐CdTe/CdS QDs by SA, a novel, simple, rapid and specific method for SA determination was proposed. The detection limit for SA was 3.4 ng/mL and the quantitative determination range was 0.2–40.0 µg/mL with a correlation coefficient of 0.9988. The method has been applied to the determination of SA in synthetic samples and fresh urine samples of healthy human with satisfactory results. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
A highly sensitive and simple method for identifying sulpiride in pharmaceutical formulations and biological fluids is presented. The method is based on increased chemiluminescence (CL) intensity of a luminol–H2O2 system in response to the addition of Cr (III) under alkaline conditions. The CL intensity of the luminol–H2O2–Cr (III) system was greatly enhanced by the addition of sulpiride and the CL intensity was proportional to the concentration of sulpiride in a sample solution. Various parameters affecting the CL intensity were systematically investigated and optimized for determination of the sulpiride in a sample. Under the optimum conditions, the CL intensity was proportional to the concentration of sulpiride in the range of 0.068–4.0 µg/mL, with a good correlation coefficient of 0.997. The limit of detection (LOD) and limit of quantification (LOQ) were found to be 8.50 × 10‐6 µg/mL and 2.83 × 10‐5 µg/mL, respectively. The method presented here produced good reproducibility with a relative standard deviation (RSD) of 2.70% (n = 7). The effects of common excipients and metal ions were studied for their interference effect. The method was validated statistically through recovery studies and successfully applied for the determination of sulpiride in pure form, pharmaceutical preparations and spiked human plasma samples. The percentage recoveries were found to range from 99.10 to 100.05% for pure form, 98.12 to 100.18% for pharmaceutical preparations and 97.9 to 101.4% for spiked human plasma. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
A novel chemiluminescence (CL) method was developed for the determination of 10‐hydroxycamptothecin(HCPT) based on the CL reaction between [Ag(HIO6)2]5? and luminol in alkaline solution. CL emission of Ag(III) complex–luminol in alkaline medium was very different from that in acidic medium. A possible mechanism of enhanced CL emission was suggested. The enhanced effect of HCPT on CL emission of the [Ag(HIO6)2]5?–luminol system was found. The enhanced degree of CL emission was proportional to HCPT concentration. The effect of the reaction conditions on CL emission was examined. Under optimal conditions, the limit of detection was 6.5 × 10?9 g mL?1. The proposed method was applied for the determination of HCPT in real samples with the recoveries of 93.2–109% with the RSD of 1.7–3.3%. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

6.
A simple, rapid and sensitive chemiluminescent (CL) method for the assay of venlafaxine (VEN) in pharmaceutical formulations and serum samples by a two‐chip device is proposed. The method is based on the reaction of this drug with a tris(2,2′‐bipyridyl) ruthenium(II)–peroxydisulphate CL system. The optimum chemical conditions for CL emission were investigated. The calibration graph was linear for the concentration range 0.02–8.0 µg/mL. The detection and quantification limits were found to be 0.006 and 0.018 µg/mL, respectively, while the relative standard deviation (RSD) was <2.0%. The present CL procedure was applied to the determination of VEN in pharmaceutical formulations and serum samples; the recovery levels were in the range 96.5–101.2%. The results suggest that the method is unaffected by the presence of common formulation excipients found in these samples. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

7.
Chemiluminescence (CL) detection for the determination of estrogen benzoate, using the reaction of tris(1,10–phenanthroline)ruthenium(II)–Na2SO3–permanganate, is described. This method is based on the CL reaction of estrogen benzoate (EB) with acidic potassium permanganate and tris(1,10–phenanthroline)ruthenium(II). The CL intensity is greatly enhanced when Na2SO3 is added. After optimization of the different experimental parameters, a calibration graph for estrogen benzoate is linear in the range 0.05–10 µg/mL. The 3 s limit of detection is 0.024 µg/mL and the relative standard deviation was 1.3% for 1.0 µg/mL estrogen benzoate (n = 11). This proposed method was successfully applied to commercial injection samples and emulsion cosmetics. The mechanism of CL reaction was also studied. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

8.
Water‐soluble thioglycolic acid (TGA)‐capped core/shell CdTe/CdS quantum dots (QDs) were synthesized. The interactions of rhein and emodin with TGA‐CdTe/CdS QDs were evaluated by fluorescence and ultraviolet‐visible absorption spectroscopy. Experimental results showed that the high fluorescence intensity of TGA‐CdTe/CdS QDs could be effectively quenched in the presence of rhein (or emodin) at 570 nm, which may have resulted from an electron transfer process from excited TGA‐CdTe/CdS QDs to rhein (or emodin). The quenching intensity was in proportion to the concentration of both rhein and emodin in a certain range. Under optimized conditions, the linear ranges of TGA‐CdTe/CdS QDs fluorescence intensity versus the concentration of rhein and emodin were 0.09650–60 µg/mL and 0.1175–70 µg/mL with a correlation coefficient of 0.9984 and 0.9965, respectively. The corresponding detection limits (3σ/S) of rhein and emodin were 28.9 and 35.2 ng/mL, respectively. This proposed method was applied to determine rhein and emodin in human urine samples successfully with remarkable advantages such as high sensitivity, short analysis time, low cost and easy operation. Based on this, a simple, rapid and highly sensitive method to determine rhein (or emodin) was proposed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
A simple and sensitive flow‐injection (FI) method for the determination of nitrate and nitrite in natural waters, based on luminol chemiluminescence (CL) detection, is reported. Nitrate was reduced online to nitrite via a copperized cadmium (Cu–Cd) column and then reacted with acidic hydrogen peroxide to form peroxynitrous acid. CL emission was observed from the oxidation of luminol in an alkaline medium in the presence of the peroxynitrite anion. The limits of detection (S:N = 3) were 0.02 and 0.01 µg N/L, with sample throughputs of 40 and 90 /h for nitrate and nitrite, respectively. Calibration graphs were linear over the range 0.02–50 and 0.01–50 µg N/L [R2 = 0.9984 (n = 8) and R2 = 0.9965 (n = 7)] for nitrate and nitrite, respectively, with relative standard deviations (RSDs; n = 3) in the range 1.8–4.6%. The key chemical and physical variables (reagent concentrations, buffer pH, flow rates, sample volume, Cu–Cd reductor column length) were optimized and potential interferences investigated. The effect of cations [Ca(II), Mg(II), Co(II), Fe(II) and Cu(II)] was masked online with EDTA. Common anions (PO43?, SO42? and HCO3?) did not interfere at their maximum admissible concentrations in freshwaters. The effect of salinity on the luminol CL reaction with and without nitrate and nitrite (2 and 0.5 µg N/L, respectively) was also investigated. The method was successfully applied to freshwaters and the results obtained were in good agreement with those obtained by an automated segmented flow analyser reference method. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

10.
The chemiluminescence (CL) behaviour of the luminol–potassium periodate system enhanced by CdTe quantum dots capped with thioglycolic acid (TGA–CdTe QDs) was studied using kinetic experiments, CL spectra, UV–vis absorption spectra and fluorescence spectra. The production of oxygen‐containing reactant intermediates (O2?? and OH?) in the present CL system was verified by CL. The possible CL mechanism was discussed in detail. Furthermore, theophylline (THP) was determined based on its enhancement of the CL intensity of the CdTe QDs–luminol–potassium periodate system coupled with a flow‐injection technique. Under these optimized conditions, the linear range was found to be from 1.0 × 10?8 to 1.0 × 10?5 g/mL with a detection limit of 2.8 × 10?9 g/mL (3σ). The recoveries for the determination of THP in tablets were from 98.2 to 99.6%.  相似文献   

11.
In this paper, a novel chemiluminescence (CL) system was introduced based on the use of CdTe quantum dots (QDs) with the mixture solutions of fluorescein and potassium periodate (KIO4) in alkaline medium. The CL signal of an ultra‐weak system was strongly enhanced in the presence of QDs. The application of CdTe QDs–fluorescein–KIO4 system is reported for the first time. It was found that catechol had a diminishing effect on the CL reaction. Under optimal experimental conditions, CL intensity decreased linearly in a 1 to 100 μM catechol concentration range, with a 0.18 μM detection limit. A possible reaction mechanism was proposed according to the results of kinetic analyses, CL spectra, ultraviolet–visible and fluorescence spectra. The results pointed to an efficient energy transfer between the CL energy donor CdTe QDs and acceptor fluorescein. Finally, the CL method was successfully applied to the determination of catechol in environmental water samples.  相似文献   

12.
A simple and highly sensitive chemiluminescence (CL) method is reported for the determination of naphazoline hydrochloride (NH). It was found that the weak CL from the reaction of luminol and KIO4 in an alkaline medium could be highly amplified by cysteine‐capped cadmium telluride quantum dots (QDs) and the enhanced CL was effectively quenched by NH and this finding was utilized as a basis for the determination of NH. The QDs were synthesized in aqueous medium and characterized by X‐ray diffraction (XRD), transmission electron microscopy (TEM), and UV‐vis and photoluminescence spectroscopy. A possible mechanism was proposed for the CL system based on radical identification experiments, along with CL spectrum of the system. The experimental parameters were optimized by the reliable response surface methodology (RSM). Under the optimized experimental conditions, the proposed method allowed the determination of NH over the range of 5.0 × 10‐10–2.0 × 10‐7 mol/L (r2 = 0.9993, n = 10). The precision (RSD%) of the method, obtained from five replicate determinations of 2.0 and 150 nmol/L NH, was found to be 1.0% and 1.3%, respectively. The method was successfully applied to the determination of NH in pharmaceutical formulations and human urine and serum samples with results corroborated with the aid of those obtained from a standard method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

13.
A sensitive and simple chemiluminescent (CL) method for the determination of clomipramine has been developed by combining the flow‐injection analysis (FIA) technique, which is based on the CL intensity generated from the redox reaction of potassium permanganate (KMnO4)–formic acid in sulphuric acid (H2SO4) medium. Under the optimum conditions, the linear range for the determination of clomipramine was 0.04–4 µg/mL, with a correlation coefficient of 0.9988 (n = 10) and a detection limit of 0.008 µg/mL (3σ), and the relative standard deviation (RSD) for 2.0 µg/mL clomipramine (n = 11) is 1.26%. The proposed method has been successfully applied to the determination of the studied clomipramine in pharmaceutical preparations. The possible reaction mechanism is discussed. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

14.
A highly sensitive, rapid and economical method for the determination of amlodipine (AM) in biological fluids was developed using a peroxyoxalate chemiluminescence (CL) system in a lab‐on‐a‐chip device. Peroxyoxalate‐CL is an indirect type of CL that allows the detection of native fluorophores or compounds derivatized with fluorescent labels. Here, fluorescamine was reacted with AM, and the derivatization product was used in a bis‐(2,4,6‐trichlorophenyl)oxalate‐CL system. Fluorescamine reacts selectively with aliphatic primary amine at neutral or basic pH. As most of the calcium channel blocker and many cardiovascular drugs do not contain primary amine, the developed method is highly selective. The parameters that influenced the CL signal intensity were studied carefully. These included the chip geometry, pH, concentration of reagents used and flow rates. Moreover, we confirmed our previous observation about the effects of imidazole, which is commonly used in the bis‐(2,4,6‐trichlorophenyl)oxalate‐CL system as a catalyst, and found that the signal was significantly improved when imidazole was absent. Under optimized conditions, a calibration curve was obtained with a linear range (10–100 µg/L). The limit of detection was 3 µg/L, while the limit of quantification was 10 µg/L. Finally the method was applied for the determination of AM in biological fluids successfully. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
CdS nanoparticles (CdS NPs) of different sizes were synthesized by the citrate reduction method. It was found that CdS NPs could enhance the chemiluminescence (CL) of the luminol‐potassium ferricyanide system and baicalin could inhibit CdS NPs‐enhanced luminol‐potassium ferricyanide CL signals in alkaline solution. Based on this inhibition, a flow‐injection CL method was established for determination of baicalin in pharmaceutical preparations and human urine samples. Under optimized conditions, the linear range for determination of baicalin was 5.0 x 10?6 to 1.0 x 10?3 g/L. The detection limit at a signal‐to‐noise ratio of 3 was 1.7 x 10 ?6 g/L. CL spectra, UV‐visible spectra and transmission electron microscopy (TEM) were used to investigate the CL mechanism. The method described is simple, selective and obviates the need of extensive sample pretreatment. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

16.
A new chemiluminescence (CL) method using flow injection has been described for the rapid and sensitive determination of promazine hydrochloride (PMH). The method is based on the CL reaction of PMH with tris(1,10 phenanthroline)ruthenium(II), [Ru(phen)32+] and Ce(IV) in sulfuric acid medium. Effects of chemical variables were investigated employing central composite design and response surface methodology. Under the optimum conditions, the CL intensity was proportional to the concentration of the drug in solution over the ranges 0.020–0.32 and 0.32–32 µg/mL. The limit of detection (signal‐to‐noise ratio = 3) was 0.012 µg/mL. The method was applied successfully to the determination of PMH in drug formulations and human serum (recovery percentages between 96.7 and 105.0%). The relative standard deviation for 11 replicate determinations of 1.5 µg/mL of PMH was 1.7%. The minimum sampling rate was 100 samples per hour. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

17.
A new method for the detection of β2 adrenergic agonists was developed based on the chemiluminescence (CL) reaction of β2 adrenergic agonist with potassium ferricyanide–luminol CL. The effect of β2 adrenergic agonists including isoprenaline hydrochloride, salbutamol sulfate, terbutaline sulfate and ractopamine on the CL intensity of potassium ferricyanide–luminol was discovered. Detection of the β2 adrenergic agonist was carried out in a flow system. Using uniform design experimentation, the influence factors of CL were optimized. The optimal experimental conditions were 1 mmol/L of potassium ferricyanide, 10 µmol/L of luminol, 1.2 mmol/L of sodium hydroxide, a flow speed of 2.6 mL/min and a distance of 1.2 cm from ‘Y2’ to the flow cell. The linear ranges and limit of detection were 10–100 and 5 ng/mL for isoprenaline hydrochloride, 20–100 and 5 ng/mL for salbutamol sulfate, 8–200 and 1 ng/mL for terbutaline sulfate, 20–100 and 4 ng/mL for ractopamine, respectively. The proposed method allowed 200 injections/h with excellent repeatability and precision. It was successfully applied to the determination of three β2 adrenergic agonists in commercial pharmaceutical formulations with recoveries in the range of 96.8–98.5%. The possible CL reaction mechanism of potassium ferricyanide–luminol–β2 adrenergic agonist was discussed from the UV/vis spectra. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

18.
A novel galangin–potassium permanganate (KMnO4)–polyphosphoric acid (PPA) system was found to have an outstanding response to tryptophan (Trp). Trp determination using this KMnO4–PPA system was enhanced significantly in the presence of galangin. A highly sensitive flow‐injection chemiluminescence (CL) method to determine Trp was developed based on the CL reaction of galangin–KMnO4–Trp in PPA media. The presence of galangin, a member of the flavonol class of flavonoid complexes, greatly increased the luminous intensity of Trp in KMnO4–PPA systems. Under optimized conditions, Trp was determined in the 0.05–10 µg/mL range, with a detection limit (3σ) of 5.0 × 10?3 µg/mL. The relative standard deviation (RSD) was 1.0% for 11 replicate determinations of 1.0 µg/mL Trp. Two synthetic samples were determined selectively with recoveries of 98.4–100.1% in the presence of other amino acids. The possible mechanism is summarized as follows: excited states of Mn(II)* and Mn(III * types are the main means of generating chemical luminescent species, and Trp concentration and luminescence intensity have a linear relationship, which enables quantitative analysis. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

19.
A novel chemiluminescence (CL) method was developed for the determination of cefazolin sodium based on the CL reaction between the [Cu(HIO6)2]5‐Cu(III) complex and luminol in alkaline solution. Results showed that CL emission of Cu(III) complex–luminol in alkaline medium was significantly different from that in acidic medium. A possible mechanism of the enhanced effect of cefazolin on CL emission of the [Cu(HIO6)2]5‐‐ luminol system was proposed. The effect of the reaction conditions on CL emissions was examined. Under optimized conditions, a good linear relationship was obtained between CL intensity and concentrations of cefazolin sodium in the range of 2.0 x 10‐8 to 2.0 x 10‐6 g/mL with a correlation coefficient of R2 = 0.9978. The limit of detection was 4.58 x 10‐9 g/mL. The proposed method was applied for the determination of cefazolin sodium in real samples with recoveries of 82.0‐109% with an RSD of 0.7‐2.1%. The proposed method was successfully used for the determination of cefazolin sodium in injectable powder preparations and human urine with satisfactory results. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
A sensitive flow‐injection chemiluminescence method for the determination of acetylsalicylic acid is described. It is based on the enhanced chemiluminescent emission of the alkaline lucigenin–H2O2 system by acetylsalicylic acid. The difference in chemiluminescent intensity of alkaline lucigenin–H2O2 in the presence of acetylsalicylic acid from that in the absence of acetylsalicylic acid was linear at acetylsalicylic acid concentrations in the range of 0.0029–47.37 µg/mL, with detection and quantification limits of 0.0011 and 0.0029 µg/mL, respectively. The correlation coefficient of the working curve was 0.9983. The relative standard deviation (n = 10) for 25 µg/mL acetylsalicylic acid is 1.95%. All experimental parameters were optimized. The method was successfully applied to the determination of acetylsalicylic acid in pharmaceutical preparations. The recovery results obtained by the method were satisfactory. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号