首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Aliskiren hemifumarate (ALS) and amlodipine besylate (AML) were simultaneously determined by two different spectrofluorimetric techniques. The first technique depends on direct measurement of the steady‐state fluorescence intensities of ALS and AML at 313 nm and 452 nm upon excitation at 290 and 375 nm, respectively, in a solvent composed of methanol and water (10: 90, v/v) . The second technique utilizes synchronous fluorimetric quantitative screening of the emission spectra of ALS and AML at 272 and 366 nm, respectively using Δλ of 97 nm. Effects of different solvents and surfactants on relative fluorescence intensity were studied. The method was validated according to ICH guidelines. Linearity, accuracy and precision were found to be satisfactory in both techniques over the concentration ranges of 1–15 and 0.4–4 µg/mL for ALS and AML, respectively. In the first technique, limit of detection and limit of quantification were estimated and found to be 0.256 and 0.776 µg/mL for ALS as well as 0.067 and 0.204 µg/mL for AML, respectively. Also, limit of detection and limit of quantification were calculated in the synchronous method and found to be 0.293 and 0.887 µg/mL for ALS as well as 0.034 and 0.103 µg/mL for AML, respectively. The methods were successfully applied for the determination of the two drugs in their co‐formulated tablets. The results were compared statistically with reference methods and no significant difference was found. The developed methods are rapid, sensitive, inexpensive and accurate for the quality control and routine analysis of the cited drugs in bulk and in pharmaceutical preparations without pre‐separation. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

2.
A rapid, simple, and sensitive second‐derivative synchronous fluorimetric method has been developed and validated for the simultaneous analysis of a binary mixture of desloratadine (DSL) and montelukast sodium (MKT) in their co‐formulated tablets. The method is based on measurement of the synchronous fluorescence intensities of the two drugs in McIlvaine's buffer, pH 2.3, in the presence of carboxy methyl cellulose sodium (CMC) as a fluorescence enhancer at a constant wavelength difference (Δλ) of 160 nm. The presence of CMC enhanced the synchronous fluorescence intensity of DSL by 216% and that of MKT by 28%. A linear dependence of the concentration on the amplitude of the second derivative synchronous fluorescence spectra was achieved over the ranges of 0.10–2.00 and 0.20–2.00 µg/mL with limits of detection of 0.02 and 0.03, and limits of quantification of 0.05 and 0.10 µg/mL for DSL and MKT, respectively. The proposed method was successfully applied for the determination of the studied compounds in laboratory‐prepared mixtures and tablets. The results were in good agreement with those obtained with the comparison method. The high sensitivity attained by the proposed method allowed the determination of MKT in spiked human plasma with average % recovery of 100.11 ± 2.44 (n = 3). Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

3.
Amlodipine besylate (AML) is available in fixed‐dose combination tablets with either candesartan cilexetil (CAN) or telmisartan (TEL). This work describes a simple, selective and sensitive spectrofluorimetric method for analysis of AML/CAN and AML/TEL binary mixtures without prior separation. The method involves measurement of the native fluorescence of AML at excitation and emission wavelengths of 367 and 454 nm, respectively, in water without interference from either of the two drugs. By contrast, the intrinsic fluorescence of CAN was measured at excitation and emission wavelengths of 265 and 392 nm, respectively, in ethanol, while TEL was measured at 366 nm in 0.05 M sodium hydroxide solution using 294 nm as the excitation wavelength. The proposed spectrofluorimetric procedure was validated with respect to linearity, ranges, precision, accuracy, selectivity, robustness, detection and quantification limits. Regression analysis showed a good correlation between fluorescence intensity and concentration over the ranges 0.1–1.4, 0.025–0.25 and 0.0025–0.05 µg/mL for AML, CAN and TEL, respectively. Limits of detection were 0.034, 0.0063 and 0.0007 µg/mL for AML, CAN and TEL, respectively. The proposed method was successfully applied for the analysis of several synthetic binary mixtures of different ratios and laboratory‐prepared tablets with good recoveries, and no interference from common pharmaceutical additives was observed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
A highly sensitive, simple and rapid spectrofluorimetric method was developed for the determination of amisulpride (AMS) and bumidazone (BUM) in tablet form. The proposed method is based on measuring the native fluorescence of the studied drugs in methanol at 360 and 344 nm after excitation at 276 and 232 nm for AMS and BUM, respectively. The fluorescence–concentration plots were rectilinear over the ranges of 5.0–60.0 ng/mL for AMS and 0.5–5.0 µg/mL for BUM. The lower detection limits were 0.70 ng/mL and 0.06 µg/mL, and the lower quantification limits were 2.0 ng/mL and 0.18 µg/mL for AMS and BUM, respectively. The method was successfully applied for the analysis of AMS and BUM in commercial tablets. Statistical evaluation and comparison of the data obtained using the proposed and comparison methods revealed good accuracy and precision for the proposed method. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

5.
Two simple, rapid and sensitive methods, namely, fourth‐derivative synchronous spectrofluorimetry (method I) and HPLC with fluorescence detection (method II) were developed for the simultaneous analysis of a binary mixture of itopride HCl (ITP) and domperidone (DOM) without prior separation. The first method was based on measuring the fourth derivative of the synchronous fluorescence spectra of the two drugs at Δλ = 40 nm in methanol. The different experimental parameters affecting the synchronous fluorescence of the studied drugs were carefully optimized. Chromatographic separation was performed in < 6.0 min using a RP C18 column (250 mm × 4.6 mm i.d., 5 µm particle size) with fluorescence detection at 344 nm after excitation at 285 nm. A mobile phase composed of a mixture of 0.02 M phosphate buffer with acetonitrile in a ratio of 55 : 45, pH 4.5, was used at a flow rate of 1 mL/min. Linearity ranges were found to be 0.1–2 µg/mL for ITP in both methods, whereas those for DOM were found to be 0.08–2 and 0.05–1.5 µg/mL in methods I and II, respectively. The proposed methods were successfully applied for the determination of the studied drugs in synthetic mixtures and laboratory‐prepared tablets. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

6.
A simple, sensitive and rapid spectrofluorimetric method was developed for the determination of esomeprazole (EMZ) and pantoprazole (PRZ) in their pharmaceutical formulations and human plasma. The proposed method is based on the fluorescence spectral behavior of EMZ in methanol in the presence of 0.1 m NaOH containing 0.5% methyl cellulose (MC) at 306/345 nm. The fluorescence intensity of EMZ was enhanced about 1.3‐fold and good linearity in the range 0.4–4.0 µg/mL with a lower detection limit of 0.04 µg/mL and lower quantification limit of 0.14 µg/mL. For PRZ, its methanolic solution exhibited marked native fluorescence at 290/325 nm after enhancement (about 2.1‐ or 1.4‐fold) using either 0.025% sodium dodecyl sulfate (SDS) or 0.05% MC in the presence of 0.2 m borate buffer of pH 9.5. The fluorescence–concentration plots of PRZ were rectilinear over the ranges 0.2–2.0 and 0.3–3.0 µg/mL with lower detection limits of 0.02 and 0.03 µg/mL and lower quantification limits of 0.07 and 0.09 µg/mL using sodium dodecyl sulfate and MC, respectively. The method was successfully applied to the analysis of EMZ and PRZ in their commercial dosage forms and the results were in good agreement with those obtained with the comparison method. Furthermore, in a preliminary investigation, the proposed method was extended to the in vitro determination of the two drugs in spiked human plasma and the results were satisfactory. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

7.
A novel method for the determination of proteins was developed, based on the enhancement of fluorescence with 4‐chloro‐(2′‐hydroxylophenylazo)rhodanine–Ti(IV) [ClHARP–Ti(IV)] complex as a fluorescence probe. The excitation and emission wavelengths of the system were 335 nm and 376 nm, respectively. The presence of bis(2‐ethylhexyl)sulphosuccinate sodium salt (AOT) microemulsion greatly increased the sensitivity of the system. Under optimal conditions, four kinds of proteins, including bovine serum albumin (BSA), human serum albumin (HSA), egg albumin (Ova), and γ‐globin (γ‐G) were studied. The detection limits were 0.182 µg/mL for BSA, 0.0788 µg/mL for HSA, 0.216 µg/mL for Ova and 0.484 µg/mL for γ‐G. The linear ranges of the calibration were 0–12.0, 0–10.0, 0–18.0 and 0–18.0 µg/mL, respectively. The method possessed high sensitivity, good selectivity and was applied to the analysis of protein in milk powder and cornmeal with satisfactory results. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

8.
A simple and rapid liquid chromatographic method was developed and validated for the determination of triclabendazole with high accuracy and precision within 6 min. Good chromatographic separation was achieved using a CLC Shim‐pack C8 (250 × 4.6 mm, 5 µm particle size) using the mobile phase containing a mixture of 0.02 m phosphate buffer and methanol with a ratio of (20 : 80 v/v) at pH 4.0 was pumped at a flow rate of 1.2 mL/min with fluorescence detection for the first time at 338 nm after excitation at 298 nm. Losartan potassium was used as an internal standard. The method showed good linearity in the ranges of 0.05–2.0 µg/mL with limits of detection and quantification of 14.1 and 42.6 ng/mL, respectively. The suggested method was successfully applied for the analysis of triclabendazole in tablets. The high sensitivity of the method enabled the determination of the studied drug in spiked human plasma with mean percentage of recoveries of 99.79 ± 5.09. Statistical evaluation of the data was performed according to ICH Guidelines. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
An innovative, simple, accurate, sensitive, and eco-friendly synchronous fluorescence spectrofluorimetric method has been developed for the simultaneous analysis of montelukast sodium (MON) and fexofenadine hydrochloride (FEX). The method relies on measuring the relative synchronous fluorescence intensity of both drugs using Δλ of 60 nm in methanol at 405 nm for MON and 288 nm for FEX. The experimental parameters influencing the developed method were investigated and optimized. The method was linear over the ranges 0.1–2.0 and 2.0–20.0 μg/ml for MON and FEX, respectively. The limits of detection were 0.018 and 0.441 μg/ml, and the limits of quantitation were 0.055 and 1.336 μg/ml for MON and FEX, respectively. The developed method was applied successfully for the determination of the two drugs in their newly released fixed-dose combination prescribed for the treatment of allergic rhinitis. The mean per cent recoveries were found to be 100.680 ± 0.890 and 100.110 ± 0.940 for MON and FEX, respectively. Furthermore, the method was found to be eco-friendly green as was evaluated according to the Green Analytical Procedure Index tool guidelines and analytical eco-scale.  相似文献   

10.
Two simple, selective and accurate methods were developed and validated for the determination of brimonidine tartrate (BT) in pure state and pharmaceutical formulations. Both methods are based on the coupling of the drug with 4‐chloro‐7‐nitro‐2,1,3‐benzoxadiazole in borate buffer (pH 8.5) at 70 °C and measurement of the reaction product spectrophotometrically at 407 nm (method I) or spectrofluorimetrically at 528 nm upon excitation at 460 nm (method II). The calibration graphs were rectilinear over the concentration ranges of 1.0–16.0 and 0.1–4.0 µg/mL with lower detection limits of 0.21 and 0.03, and lower quantification limits of 0.65 and 0.09 µg/mL for methods I and II, respectively. Both methods were successfully applied to the analysis of commercial ophthalmic solution with mean recovery of 99.50 ± 1.00 and 100.13 ± 0.71%, respectively. Statistical analysis of the results obtained by the proposed methods revealed good agreement with those obtained using a comparison method. The proposed spectrofluorimetric method was extended to a stability study of BT under different ICH‐outlined conditions such as alkaline, acidic, oxidative and photolytic degradation. Furthermore, the kinetics of oxidative degradation of the drug was investigated and the apparent first‐order reaction rate constants, half‐life times and Arrhenius equation were estimated. The proposed methods are practical and valuable for routine applications in quality control laboratories for the analysis of BT. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

11.
M. M. Tolba 《Luminescence》2014,29(7):738-748
A simple and sensitive high‐performance liquid chromatography method was developed and validated for the determination of calcium dobesilate (DOB) or ethamsylate (ETM) in the presence of their degradation product, hydroquinone (HQ). The analyses were carried out on Promosil C18 column (4.6 mm × 250 mm, 5 µm particle size) using an ion‐pair mobile phase consisting of methanol–1.5 mm tetra‐butyl ammonium bromide in 0.06 m phosphate buffer (25 : 75, v/v) at pH 6.0 with fluorescence detection at 286/333 nm. Pindolol was used as an internal standard. The proposed method was found to be rectilinear over the concentration ranges of 0.05–0.5 µg/mL for DOB, 0.1–0.8 µg/mL for ETM and 0.005–0.1 µg/mL for HQ. The method was applied for the determination of the studied drugs in different dosage forms and biological fluids. The results of the proposed method were statistically compared with those obtained by the comparison methods revealing no significance differences in the performance of the methods regarding accuracy and precision. Moreover, applying a time‐programmed fluorescence technique was valuable for the detection of trace amounts of HQ as an impurity and allowed purity testing of ETM or DOB within the BP pharmacopeial limit (0.1%). Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

12.
Propofol and cisatracurium besylate have been simultaneously determined using a highly sensitive first derivative synchronous spectrofluorometric method. The method is based on measuring first derivative synchronous spectrofluorimetric amplitude at Δλ = 40 nm with a scanning rate of 600 nm/min. The different experimental parameters affecting the fluorescence intensity of the two drugs were carefully studied and optimized. The amplitude–concentration plots were rectilinear over the range 40.0–400.0 ng/mL and 20.0–280.0 ng/mL for propofol and cisatracurium, respectively with lower detection limits of 4.0 and 2.35 ng/mL and quantification limits of 12.1 and 7.1 ng/mL for propofol and cisatracurium, respectively. The proposed method was successfully applied for the determination of the two compounds in synthetic mixtures and in commercial ampoules. The high sensitivity attained using the proposed method allowed the simultaneous determination of both drugs in spiked plasma samples. The mean % recoveries in spiked human plasma (n = 3) were 96.53 ± 0.90 and 96.20 ± 1.64 for each of propofol and cisatracurium, respectively. The method was validated in compliance with International Council of Harmonization (ICH) Guidelines.  相似文献   

13.
A new combination of ibuprofen (NSAID) and famotidine (H2 receptor antagonist) was recently approved by the FDA. It was formulated to relief pain while decreasing the risk of ulceration, which is a common problem for patients receiving NSAID. A rapid and simple derivative emission spectrofluorimetric method is proposed for the simultaneous analysis of this combination in their pharmaceutical preparation. The method is based upon measurement of the native fluorescence intensity of the two drugs at λex = 233 nm in acetonitrile. The emission data were differentiated using the first (D1) derivative technique. The plots of derivative fluorescence intensity versus concentration were rectilinear over a range of 2–35 and 0.4–8 µg/mL for both ibuprofen (IBU) and famotidine (FAM), respectively. The method was sensitive as the limits of detection were 0.51 and 0.12 µg/mL and limits of quantitation were 1.70 and 0.39 µg/mL, for IBU and FAM respectively. The proposed derivative emission spectrofluorimetric method was successfully applied for the determination of the two drugs in their synthetic mixtures and tablets with good accuracy and precision. The proposed method was validated as per ICH guidelines. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

14.
Water‐soluble thioglycolic acid (TGA)‐capped core/shell CdTe/CdS quantum dots (QDs) were synthesized. The interactions of rhein and emodin with TGA‐CdTe/CdS QDs were evaluated by fluorescence and ultraviolet‐visible absorption spectroscopy. Experimental results showed that the high fluorescence intensity of TGA‐CdTe/CdS QDs could be effectively quenched in the presence of rhein (or emodin) at 570 nm, which may have resulted from an electron transfer process from excited TGA‐CdTe/CdS QDs to rhein (or emodin). The quenching intensity was in proportion to the concentration of both rhein and emodin in a certain range. Under optimized conditions, the linear ranges of TGA‐CdTe/CdS QDs fluorescence intensity versus the concentration of rhein and emodin were 0.09650–60 µg/mL and 0.1175–70 µg/mL with a correlation coefficient of 0.9984 and 0.9965, respectively. The corresponding detection limits (3σ/S) of rhein and emodin were 28.9 and 35.2 ng/mL, respectively. This proposed method was applied to determine rhein and emodin in human urine samples successfully with remarkable advantages such as high sensitivity, short analysis time, low cost and easy operation. Based on this, a simple, rapid and highly sensitive method to determine rhein (or emodin) was proposed. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

15.
Rapid, simple and sensitive derivative emission spectrofluorimetric methods have been developed for the simultaneous analysis of binary mixtures of guaifenesin (GUA) and phenylephrine hydrochloride (PHE). The methods are based upon measurement of the native fluorescence intensity of the two drugs at λex = 275 nm in methanolic solutions, followed by differentiation using first (D1) and second (D2) derivative techniques. The derivative fluorescence intensity–concentration plots were rectilinear over a range of 0.1–2 µg/mL for both GUA and PHE. The limits of detection were 0.027 (D1, GUA), 0.025 (D2, GUA), 0.031 (D1, PHE) and 0.033 (D2, PHE) µg/mL and limits of quantitation were 0.089 (D1, GUA), 0.083 (D2, GUA), 0.095 (D1, PHE) and 0.097 (D2, PHE) µg/mL. The proposed derivative emission spectrofluorimetric methods (D1 and D2) were successfully applied for the determination of the two compounds in binary mixtures and tablets with high precision and accuracy. The proposed methods were fully validated as per ICH guidelines. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
A sensitive and simple spectrofluorimetric method has been developed and validated for the determination of the anti‐epileptic drug carbamazepine (CBZ) in its dosage forms. The method was based on a nucleophilic substitution reaction of CBZ with 4‐chloro‐7‐nitrobenzo‐2‐ oxa‐1,3‐diazole (NBD‐Cl) in borate buffer (pH 9) to form a highly fluorescent derivative that was measured at 530 nm after excitation at 460 nm. Factors affecting the formation of the reaction product were studied and optimized, and the reaction mechanism was postulated. The fluorescence–concentration plot is rectilinear over the range of 0.6–8 µg/mL with limit of detection of 0.06 µg/mL and limit of quantitation of 0.19 µg/mL. The method was applied to the analysis of commercial tablets and the results were in good agreement with those obtained using the reference method. Validation of the analytical procedures was evaluated according to ICH guidelines. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

17.
A highly sensitive and simple spectrofluorimetric method was developed for the determination of loratadine (LRT) and desloratadine (DSL) in their pharmaceutical formulations. The proposed method is based on investigation of the fluorescence spectral behaviour of LRT and DSL in a sodium dodecyl sulphate (SDS) micellar system. In aqueous solution of acetate buffer of pH 4.5, the fluorescence intensities of both LRT and DSL were greatly enhanced (240%) in the presence of SDS. The fluorescence intensity was measured at 438 nm after excitation at 290 nm for both drugs. The fluorescence–concentration plots were rectilinear over the range 0.05–2.0 µg/mL for both LRT and DSL, with lower detection limits of 5.13 × 10?3 and 6.35 × 10?3 µg/mL for LRT and DSL, respectively. The method was successfully applied to the analysis of the two drugs in their commercial tablets, capsules and syrups, and the results were in good agreement with those obtained with the official or comparison methods. The proposed method is specific for the determination of LRT in the presence of other co‐formulated drugs, such as pseudoephedrine. The application of the proposed method was extended to stability studies of LRT and DSL after exposure to different forced degradation conditions, such as acidic, alkaline and oxidative conditions, according to ICH guidelines. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

18.
Two simple, rapid, sensitive and precise spectrophotometric and spectrofluorimetric methods were developed for the determination of indacaterol maleate in bulk powder and capsules. Both methods were based on the direct measurement of the drug in methanol. In the spectrophotometric merthod (Method I) the absorbance was measured at 259 nm. The absorbance‐concentration plot was rectilinear over the range 1.0–10.0 µg mL?1 with a lower detection limit (LOD) of 0.078 µg mL?1 and lower quantification limit (LOQ) of 0.238 µg mL?1. Meanwhile in the spectrofluorimetric method (Method II) the native fluorescence was measured at 358 nm after excitation at 258 nm. The fluorescence‐concentration plot was rectilinear over the range of 1.0–40.0 ng mL?1 with an LOD of 0.075 ng mL?1and an LOQ of 0.226 ng mL?1. The proposed methods were successfully applied to the determination of indacaterol maleate in capsules with average percent recoveries ± RSD% of 99.94 ± 0.96 for Method I and 99.97 ± 0.81 for Method II. In addition, the proposed methods were extended to a content uniformity test according to the United States Pharmacopoeia (USP) guidelines and were accurate, precise for the capsules studied with acceptance value 3.98 for Method I and 2.616 for Method II. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
A simple and sensitive spectrofluorimetric method has been developed and validated for the determination of oseltamivir phosphate (OST) in pharmaceutical preparations. The method is based on the reaction between oseltamivir phosphate and o‐phthalaldehyde in presence of 2‐mercapto‐ethanol in borate buffer, pH 10.8, to give a highly fluorescent product measured at 450 nm after excitation at 336 nm. The different experimental parameters affecting the development and stability of the reaction product were studied and optimized. The fluorescence intensity–concentration plot is rectilinear over the range 0.05–1.0 µg/mL, with a lower detection limit of 5 ng/mL and limit of quantitation of 16 ng/mL. The developed method was successfully applied to the analysis of the drug in its commercial capsules and suspension, mean recoveries of OST were 99.97 ± 1.67% and 100.17 ± 1.18%, respectively (n = 3). Statistical comparison of the results obtained by the proposed and comparison method revealed no significant difference in the performance of the two methods regarding accuracy and precision. The proposed method was further extended to in vitro determination of the studied drug in spiked human plasma as a preliminary investigation; the mean recovery (n = 3) was 98.68 ± 5.8%. A reaction pathway was postulated. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

20.
A simple, sensitive and rapid HPLC method with fluorescence detection for the determination of dimethyl‐4,4′‐dimethoxy‐5,6,5′,6′‐dimethylene dioxybiphenyl‐2,2′‐dicarboxylate (DDB) in the raw material and pill form was developed. Liquid chromatography was performed on a C18 column (250 × 4.6 mm i.d., 5 µm particle size), the mobile phase consisted of methanol and 0.05 M sodium dihydrogen phosphate buffer (80 : 20, v/v), and the apparent pH of the mobile phase was adjusted to 3. The fluorescence detector was operated at excitation/emission wavelengths of 275/400 nm. The proposed method allows the determination of DDB within concentration range 0.1–1.5 µg/mL with a limit of detection of 0.032 µg/mL, a limit of quantification of 0.097 µg/mL and a correlation coefficient of 0.9997. The proposed method has been successfully applied for the analysis of DDB in its pills with a percentage recovery of 98.45 ± 0.32. The method was fully validated according to ICH guidelines. Moreover, the high sensitivity of the method permits its use in an in vitro dissolution test for DDB under simulated intestinal conditions. In addition, the proposed method was extended to a content uniformity test according to USP guidelines. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号