首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
R. POFFÉ AND E. OP DE BEECK. 1991. Influents, effluents and sludges from sewage purification plants and surface water samples were examined quantitatively for Aeromonas hydrophila on the mA medium of Rippey and Cabelli. Between 104 and 106/ml A. hydrophila were found in domestic wastewaters. On the average 99.975% were removed by activated sludge and 98.25% by trickling filters. Only 20.9% of A. hydrophila end up in the primary sludge, which contained up to 107/g dry sludge. After 3 months, anaerobically (methane) fermented and partially dried sludge from trickling filters contained more than 106 A. hydrophila /g dry sludge. Surface water receiving raw sewage contained several hundreds of A. hydrophila /ml, comparable with the numbers found in effluent waters, while surface water receiving no municipal wastewater and destined for the preparation of drinking water contained only small and negligible numbers. It was concluded that A. hydrophila was omnipresent in surface water.  相似文献   

2.
The Removal of Salmonellas in Conventional Sewage Treatment Processes   总被引:2,自引:2,他引:0  
The numbers of salmonellas in raw sewage entering a treatment plant varied hourly and diurnally; their peak concentration preceded the peak influent waste water flow into the plant by about 2 hours. Salmonellas were detected in all raw influent samples collected from 2 sewage works and the mean population level at the daily peak period was 3000 organisms/1. On average. 70–80% of the salmonellas were removed during primary sedimentation when upwards of 74–84% of solids were removed. Biological treatment and secondary sedimentation removed a further 70–100% of the pathogen. Compared with the activated sludge process the trickling filters were less efficient in removing salmonellas and they were adversely affected by increased loading following rainfall. Considering the whole treatment process, the Guildford works with its activated sludge treatment removed an average of 99–83% salmonellas while the Woking works with its trickling filter plant removed an average of 93–04% of the organisms. The large variance in the numbers of salmonellas in the final effluent from the trickling filters suggest that greater emphasis should be placed on the actual quality of the effluent rather than on percentage removal efficiencies.  相似文献   

3.
Coliform and fecal coliform populations found in the raw sewages and final sewage effluents of the prairie provinces and the Northwest Territories were examined for antibiotic resistance and the possession of R factors. It was determined that 8.91% of the total coliform and 10.80% of the fecal coliform populations carried R factors. The following numbers of combinations of R determinants were found: 39 in the Escherichia coli population, 6 in the Citrobacter population, 20 in the Enterobacter populations, 10 in the Klebsiella populations, and 11 in the Aeromonas populations. The maximum number of R determinants transferable simultaneously was seven; organisms with R factors containing determinants for chloramphenicol usually contained determinants for ampicillin. Of the coliform and fecal coliform populations, 2 to 4% were resistant to chloramphenicol in some provinces, and from 17 to 30% of the populations were resistant to three or more antibiotics. It was calculated that coliforms containing R factors in the raw sewage reached population levels of 1.5 X 10(7)/100 ml, and fecal coliforms containing R factors reached population levels of 8.6 X 10(5) ml. Final effluent discharges to the receiving environment contained R factor-containing coliform and fecal coliform populations of 3.1 X 10(4)/100 ml and 5.8 X 10(2)/100 ml, respectively. The incidence of bacteria containing R factors in sewage appears to be increasing with time, and their removal from sewage before discharge to the receiving environment is desirable. Consideration of data on bacteria with R factors should be made in future water quality deliberations and in discharge regulations.  相似文献   

4.
Activated sludge from the refinery of a plant producing synthetic rubber was shown to adsorb mercury ions contained in the sewage. As a result, the content of microorganisms in the sludge as well as the activity of dehydrogenase decreased. The quantity of Pseudomonas aeruginosa cells was 40 x 10(6) per 1 ml in a chemically defined medium without mercury ions, 20 x 10(5) per 1 ml in the water after the first sedimentation tank (0.07 to 0.08 mg Hg per litre), and 10 x 10(6) per 1 ml in the water of sewage common to the whole plant (0.13 to 0.14 mg Hg per litre). The use of the phage-resistant P-aeruginosa T-76 culture adapted to synthetic organic pollutants contained in the sewage of the plant together with the activated sludge of the refinery increased the biological activity of the sludge and improved the quality of purification in terms of dehydrogenase activity and chemical uptake of oxygen.  相似文献   

5.
Coliforms as a measure of sewage contamination of the River Zambezi   总被引:1,自引:0,他引:1  
The effect of releasing untreated sewage from Victoria Falls Town into the Zambezi river was determined by bacteriological examination of water samples collected upstream of Victoria Falls and for 22 km downstream. Most probable numbers of faecal coliforms and Escherichia coli were estimated. Water upstream of the falls, on the Zimbabwe side of the river, contained between seven and 130 E. coli per 100 ml. This section of the river was free from major sources of faecal pollution. Below the falls, but before the Victoria Falls Town sewage outfall, numbers of E. coli were between 1.8 X 10(2) and 1.4 X 10(4)/100 ml, indicating the existence of a sewage discharge other than that from Victoria Falls Town. The river was also highly polluted from the Victoria Falls Town sewage outfall to a point 18.6 km downstream. The highest E. coli count was 3.3 X 10(4)/100 ml and declined slowly to 1.4 X 10(3)/100 ml 18.6 km downstream of the outfall.  相似文献   

6.
The application of sewage sludge to agricultural land is widely used in France. To determine the impact of sludge treatments, concentrations of Listeria sp., Listeria monocytogenes and faecal indicators were monitored in five types of sludge from three sewage treatment plants in Angers (France) and its suburbs over a 1-year period. On the whole, bacteria were reduced in numbers through sludge treatments. Apart from liming, which leads to reduced levels of bacteria below detection limits, other sludge treatments did not eliminate Listeria sp. and faecal indicators. Listeria sp. and L. monocytogenes were found respectively in 87% and 73% of dewatered sludges and in 96% and 80% of sludges stored in tanks. Concentrations of L. monocytogenes, ranging from 0.15 to 20 MPN g(-1) dry matter in dewatered sludge and from 1 to 240 MPN g(-1) dry matter in sludge stored in tanks, did not show seasonal variations. Spreading of sanitised sludge onto agricultural land results in the addition of 10(6)-10(8) L. monocytogenes per hectare per year, which may contribute to the increase in the dissemination of this pathogenic species in the environment.  相似文献   

7.
Anaerobically digested dewatered sludge (10 to 15 cm thick) was applied to a forest clearcut as a fertilizer source in northwest Washington on gravelly glacial outwash soil. This sludge is not microbiologically sterile and may contain pathogenic organisms. Fecal coliform bacterial counts in sludge applied in summer (July) fell from 1.08 X 10(5) to 358/g in 204 days and to 0/g in 267 days. Dieoff appeared more rapid in winter (January)-applied sludge, when colnts fell from 1.2 X 10(5) to 20/g in 162 days. Initial death rates were related to sludge temperature, moisture, pH, physical composition, and microbial competition. Aftergrowth of fecal coliforms occurred in warm summer and fall months, but counts were of similar magnitude to background levels in forest soils, where a maximum count of 54/g was recorded. Total coliform counts in fresh sludge ranged from 1.4 X 10(4) to 1.9 X 10(6)/g. Numbers stabilized at 10(3) to 10(4)/g in spring, fall, and summer, with lower numbers in winter. Both total and fecal bacteria moved from the sludge to the soil beneath, but few penetrated past the first 5 cm. The soil acts as an effective biological filter. Few fecal coliform bacteria were recorded in the groundwater, generally being less than 5/100 ml and mostly 0/100 ml. A maximum count of 52/100 ml was recorded. Groundwater contamination from vertical movement of potential pathogens appears unlikely, but hazards from surface runoff and direct handling in the first year may arise.  相似文献   

8.
Anaerobically digested dewatered sludge (10 to 15 cm thick) was applied to a forest clearcut as a fertilizer source in northwest Washington on gravelly glacial outwash soil. This sludge is not microbiologically sterile and may contain pathogenic organisms. Fecal coliform bacterial counts in sludge applied in summer (July) fell from 1.08 X 10(5) to 358/g in 204 days and to 0/g in 267 days. Dieoff appeared more rapid in winter (January)-applied sludge, when colnts fell from 1.2 X 10(5) to 20/g in 162 days. Initial death rates were related to sludge temperature, moisture, pH, physical composition, and microbial competition. Aftergrowth of fecal coliforms occurred in warm summer and fall months, but counts were of similar magnitude to background levels in forest soils, where a maximum count of 54/g was recorded. Total coliform counts in fresh sludge ranged from 1.4 X 10(4) to 1.9 X 10(6)/g. Numbers stabilized at 10(3) to 10(4)/g in spring, fall, and summer, with lower numbers in winter. Both total and fecal bacteria moved from the sludge to the soil beneath, but few penetrated past the first 5 cm. The soil acts as an effective biological filter. Few fecal coliform bacteria were recorded in the groundwater, generally being less than 5/100 ml and mostly 0/100 ml. A maximum count of 52/100 ml was recorded. Groundwater contamination from vertical movement of potential pathogens appears unlikely, but hazards from surface runoff and direct handling in the first year may arise.  相似文献   

9.
Occurrence of Cytophagas in Sewage Plants   总被引:6,自引:4,他引:2       下载免费PDF全文
With the application of plate count methods and of the KOH-flexirubin test, bacteria belonging to the Cytophaga group were proved to occur regularly in samples from biological sewage treatment facilities. Generally, the percentage of Cytophaga colonies of the total heterotrophic colonies was lowest in the inflow sewage water as compared with the values found in activated sludge, trickling filter, and effluent samples. During an observation period of 16 months, the highest percentages of cytophagas were found in winter samples from activated sludge and trickling filters. Furthermore, cytophagas were shown to have high percentages of the bacteria lytic to polymeric substrates such as cellulose, chitin, dextran, pectin, xylan, and gelatin. Thus, it is suggested that cytophagas may contribute to sewage purification, especially at cold temperatures and by polymer breakdown. Cytophaga strains isolated were shown to have gliding motility, flexirubin pigmentation, and a low guanine plus cytosine base ratio in common. The strains were roughly subdivided into a spreading, a nonspreading, and a cellulolytic group.  相似文献   

10.
A pot experiment was conducted to investigate the effect of nickel concentration on physiological characteristics of Alyssum murale when grown in a soil mixed with sewage sludge (at the rate of 2.8%). Two types of sludge were used: agricultural sewage sludge (S1) and industrial sewage sludge with an increasing nickel concentration (S2, S3, and S4). Results showed that Ni in shoots was higher than Ni in roots. A. murale is able to concentrate up to 12730 mg/kg Ni in leaves. The highest dry matter yield was observed with plants grown with agricultural sewage sludge. An addition of S2 and S3 increased shoot biomass. However, application of S4 reduced 40% shoot dry weight as compared to the control Ni treatment did not affect all chlorophyll fluorescence parameters. The F(v)/F(m) ratio was stable between Ni treatments. Photosynthesis rate (A) increased with agricultural sewage sludge, but remained stable with variable Ni rates from the industrial sludge. The chlorophyll content increased with S1, S2 and S3 but it remains constant with S4 when compared to the control Therefore, high nickel concentration did not affect the function of the photosynthetic machine of A. murale.  相似文献   

11.
Composted sewage sludge may be used to improve soil quality, but there remains some doubt concerning the microbiological safety of the product. Sewage sludge composts from 30 municipalities were sampled, and four samples (12%) contained salmonellae (two contained fewer than 0.3/g, and the other two had 21/g and 1.7 X 10(4)/g). All 30 composts were inoculated with salmonellae; the populations decreased at a specific death rate of about 0.15 h-1 over 24 h at 36 degrees C. In irradiation-sterilized composts inoculated with salmonellae, the salmonellae grew at a rate of 0.65 doublings per h for over 24 h. Growth and death rates were found to be moisture and flora associated. The growth or death rates for antibiotic-resistant salmonellae were not different from those of nonresistant strains. It was concluded that the active indigenous flora of compost establishes a homeostatic barrier to colonization by salmonellae, and in the absence of competing flora, reinoculated salmonellae may grow to potentially hazardous densities. The active microflora of moist composts eliminated contaminating salmonellae (10(5)/g) after 6 weeks.  相似文献   

12.
Composted sewage sludge may be used to improve soil quality, but there remains some doubt concerning the microbiological safety of the product. Sewage sludge composts from 30 municipalities were sampled, and four samples (12%) contained salmonellae (two contained fewer than 0.3/g, and the other two had 21/g and 1.7 X 10(4)/g). All 30 composts were inoculated with salmonellae; the populations decreased at a specific death rate of about 0.15 h-1 over 24 h at 36 degrees C. In irradiation-sterilized composts inoculated with salmonellae, the salmonellae grew at a rate of 0.65 doublings per h for over 24 h. Growth and death rates were found to be moisture and flora associated. The growth or death rates for antibiotic-resistant salmonellae were not different from those of nonresistant strains. It was concluded that the active indigenous flora of compost establishes a homeostatic barrier to colonization by salmonellae, and in the absence of competing flora, reinoculated salmonellae may grow to potentially hazardous densities. The active microflora of moist composts eliminated contaminating salmonellae (10(5)/g) after 6 weeks.  相似文献   

13.
Budding methylotrophic bacteria resembling Hyphomicrobium spp. were counted for 12 months in a German sewage treatment plant by most-probable-number (MPN) methods. Influent samples contained up to 2 x 10(sup4) cells ml(sup-1), activated sludge consistently contained 1 x 10(sup5) to 5 x 10(sup5) cells ml(sup-1), and the effluent contained 1 x 10(sup3) to 4 x 10(sup3) cells ml(sup-1). The receiving lake had only 2 to 12 cells ml(sup-1). Six morphological groups with different growth requirements could be observed among 1,199 pure cultures that had been isolated from MPN dilutions. With dot blot DNA hybridizations, 671 isolates were assigned to 30 hybridization groups (HGs) and 84 could not be classified. Only HG 22 hybridized with a known species, Hyphomicrobium facilis IFAM B-522. Fourteen HGs (HGs 8 to 20 and HG 22) were specific for the lake; most others occurred only in the treatment plant. HGs 1, 3, and 26 were found in the activated sludge tank throughout the year, and HGs 27 and 28 were found for most of the year. In summary, it was demonstrated that bacteria with nearly identical and specific morphologies and nutritional types showed a high level of genetic diversity, although they were isolated under the same conditions and from the same treatment plant or its receiving lake. A directional exchange of these genetically different populations was possible but less significant, as was shown by the establishment of distinct populations in specific stations.  相似文献   

14.
Sewage treatment plant effluents were surveyed for viral contributions to gastroenteritis outbreaks in Puerto Rico. Of the 15 sewage treatment plants studied, all discharged their effluents upstream from water treatment plant intakes. No base-line data on the degree of viral challenge to these sewage treatment plants or the subsequent reduction of viruses before discharge existed. Enterovirus counts were generally much higher than those found in the continental United States. At four plants, viruses in the incoming sewage exceeded 100,000 PFU/liter, and one of these, a trickling filter plant, was discharging 24,000 PFU/liter to receiving waters. Virus identification showed that more than 80% of the enterovirus isolates were coxsackievirus B5. These overwhelming viral numbers pointed to defects in the sewage treatment processes. Without reasonable barriers to protect receiving waters, several of the downstream communities were using raw waters that posed extraordinary demands on the ability of their water treatment plants to supply virologically safe drinking water.  相似文献   

15.
Sewage treatment plant effluents were surveyed for viral contributions to gastroenteritis outbreaks in Puerto Rico. Of the 15 sewage treatment plants studied, all discharged their effluents upstream from water treatment plant intakes. No base-line data on the degree of viral challenge to these sewage treatment plants or the subsequent reduction of viruses before discharge existed. Enterovirus counts were generally much higher than those found in the continental United States. At four plants, viruses in the incoming sewage exceeded 100,000 PFU/liter, and one of these, a trickling filter plant, was discharging 24,000 PFU/liter to receiving waters. Virus identification showed that more than 80% of the enterovirus isolates were coxsackievirus B5. These overwhelming viral numbers pointed to defects in the sewage treatment processes. Without reasonable barriers to protect receiving waters, several of the downstream communities were using raw waters that posed extraordinary demands on the ability of their water treatment plants to supply virologically safe drinking water.  相似文献   

16.
Aeromonas hydrophila: Ecology and Toxigenicity of Isolates from an Estuary   总被引:8,自引:7,他引:1  
A microbiological survey of Aeromonas hydrophila in Chesapeake Bay and its tributaries showed that this species is ubiquitous, occurring in numbers ranging from <0.3/l to 5 × 103/ml in the water column and ca. 4.6 × 102/g in sediment. It was recovered from water samples collected at several locations in Chesapeake Bay representing various salinity regimes, but the numbers of A. hydrophila in higher salinity water, i.e. 15O/OO, were low. Results of stepwise multiple linear regression analysis showed that concentrations of A. hydrophila were correlated with total, aerobic, viable, heterotrophic, bacterial counts, and, in addition, were inversely related to salinity and to concentration of dissolved oxygen. Seasonal occurrence was recorded, with fewer strains of A. hydrophila encountered during the winter months. The potential pathogenicity of A. hydrophila strains isolated from Chesapeake Bay was estimated by testing selected isolates for toxigenicity, using the Y-1 adrenal cell assay. Of 116 isolates tested, 83 (71%) produced a cytotoxic response, a characteristic found to be correlated with the lysine decarboxylase and Voges-Proskauer reactions. Eight of 11 strains tested, which elicited fluid accumulation in the rabbit ligated ileal loop assay, also provoked a cytotoxic reaction in the Y-l adrenal cell assay. Results of the study indicate that large numbers of toxigenic A. hydrophila can be found in an estuary and such strains may be pathogenic for man and/or animals.  相似文献   

17.
Spores, sporeforming vegetative cells, and asporogenous populations were enumerated in two semicontinuous anaerobic fermentors digesting municipal primary sludge at 35 and 55 degrees C for more than 87 days. In the 35 degrees C fermentor, the anaerobic total population was 312.5 X 10(6)/ml, with 25.0 X 10(6)/ml being sporogenous. The populations that digest casein, starch, pectin, and cellulose were 23.1 X 10(6), 59.2 X 10(6), 26.2 X 10(6), and 7.3 X 10(6)/ml, respectively, with 2.8 X 10(6), 6.7 X 10(6), 3.4 X 10(6), and 1.5 X 10(6)/ml being sporogenous, respectively. The sporeformers accounted for 8.0 to 20.0% of each of the respective populations. In the 55 degrees C fermentor, the anaerobic total population was 512.5 X 10(6)/ml, with 336.6 X 10(6)/ml being sporogenous. The populations that digest casein, starch, pectin, and cellulose were 97.7 X 10(6), 190.7 X 10(6), 75.8 X 10(6), and 11.2 X 10(6)/ml, respectively, with 47.8 X 10(6), 110.6 X 10(6), 43.3 X 10(6), and 5.1 X 10(6)/ml, respectively, being sporogenous. The sporeformers represented 45.5 to 65.7% of each of the respective populations. The numbers of thermophilic sporeforming vegetative cells in the 55 degrees C fermentor were 9.0 to 19.8 times higher than their counterparts in the 35 degrees C fermentor. Most sporeformers were in the vegetative state in the 35 and 55 degrees C fermentors. After 18 days of fermentation at 55 degrees C, sporeformers carried out most of the digestion; however, the digestion was shared by both sporeformers and asporogenous bacteria after 87 days of fermentation. In the 35 degrees C fermentor, asporogenous bacteria digested most of the sludge. During the 18- and 87-day experimental periods, sporeformers were never predominant.  相似文献   

18.
A rapid and sensitive assay was developed for detection of small numbers of Campylobacter jejuni and Campylobacter coli cells in environmental water, sewage, and food samples. Water and sewage samples were filtered, and the filters were enriched overnight in a nonselective medium. The enrichment cultures were prepared for PCR by a rapid and simple procedure consisting of centrifugation, proteinase K treatment, and boiling. A seminested PCR based on specific amplification of the intergenic sequence between the two Campylobacter flagellin genes, flaA and flaB, was performed, and the PCR products were visualized by agarose gel electrophoresis. The assay allowed us to detect 3 to 15 CFU of C. jejuni per 100 ml in water samples containing a background flora consisting of up to 8, 700 heterotrophic organisms per ml and 10,000 CFU of coliform bacteria per 100 ml. Dilution of the enriched cultures 1:10 with sterile broth prior to the PCR was sometimes necessary to obtain positive results. The assay was also conducted with food samples analyzed with or without overnight enrichment. As few as 相似文献   

19.
M Chen 《Applied microbiology》1987,53(10):2414-2419
Spores, sporeforming vegetative cells, and asporogenous populations were enumerated in two semicontinuous anaerobic fermentors digesting municipal primary sludge at 35 and 55 degrees C for more than 87 days. In the 35 degrees C fermentor, the anaerobic total population was 312.5 X 10(6)/ml, with 25.0 X 10(6)/ml being sporogenous. The populations that digest casein, starch, pectin, and cellulose were 23.1 X 10(6), 59.2 X 10(6), 26.2 X 10(6), and 7.3 X 10(6)/ml, respectively, with 2.8 X 10(6), 6.7 X 10(6), 3.4 X 10(6), and 1.5 X 10(6)/ml being sporogenous, respectively. The sporeformers accounted for 8.0 to 20.0% of each of the respective populations. In the 55 degrees C fermentor, the anaerobic total population was 512.5 X 10(6)/ml, with 336.6 X 10(6)/ml being sporogenous. The populations that digest casein, starch, pectin, and cellulose were 97.7 X 10(6), 190.7 X 10(6), 75.8 X 10(6), and 11.2 X 10(6)/ml, respectively, with 47.8 X 10(6), 110.6 X 10(6), 43.3 X 10(6), and 5.1 X 10(6)/ml, respectively, being sporogenous. The sporeformers represented 45.5 to 65.7% of each of the respective populations. The numbers of thermophilic sporeforming vegetative cells in the 55 degrees C fermentor were 9.0 to 19.8 times higher than their counterparts in the 35 degrees C fermentor. Most sporeformers were in the vegetative state in the 35 and 55 degrees C fermentors. After 18 days of fermentation at 55 degrees C, sporeformers carried out most of the digestion; however, the digestion was shared by both sporeformers and asporogenous bacteria after 87 days of fermentation. In the 35 degrees C fermentor, asporogenous bacteria digested most of the sludge. During the 18- and 87-day experimental periods, sporeformers were never predominant.  相似文献   

20.
The efficacy of a rotary-tube type of trickling filter for removing coxsackievirus A9, poliovirus 1, and echovirus 12 suspended in raw settled sewage was investigated. At filtration rates equivalent to about 10 MGD (million gallons per day)/acre (ca. 3,785 m3/day per acre), the filters removed 95% of the poliovirus, 83% of echovirus 12, and 94% of coxsackievirus A9. Coliform, fecal streptococci, biochemical oxygen demand, and chemical oxygen demand removals were remarkably similar, averaging 94, 92, 93, and 95%, respectively. At filtration rates equivalent to about 23 MGD/acre, 59% of the poliovirus, 63% of the echovirus 23, and 81% of the coxsackievirus A9 were removed. Coliform, fecal streptococci, biochemical oxygen demand, and chemical oxygen demand removals at this filtration rate were 68, 75, 72, and 56%, respectively. Viruses were assumed to be adsorbed to the biological slime growing in the filters, but attempts to disassociate the viruses from the slime were unsuccessful, indicating that the slime-virus complex is very stable or that the viruses were somehow inactivated. The data indicate that coliform and fecal streptococci reductions in this type sewage treatment process can be used as an index of virus reduction. Disinfection, however, must be used to ensure a virus-free final effluent.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号