首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
At functional residual capacity, lung expansion is more uniform in the prone position than in the supine position. We examined the effect of positive airway pressure (Paw) on this position-dependent difference in lung expansion. In supine and prone rabbits postmortem, we measured alveolar size through dependent and nondependent pleural windows via videomicroscopy at Paw of 0 (functional residual capacity), 7, and 15 cmH2O. After the chest was opened, alveolar size was measured in the isolated lung at several transpulmonary pressures (Ptp) on lung deflation. Alveolar mean linear intercept (Lm) was measured from the video images taken in situ. This was compared with those measured in the isolated lung to determine Ptp in situ. In the supine position, the vertical Ptp gradient increased from 0.52 cmH2O/cm at 0 cmH2O Paw to 0.90 cmH2O/cm at 15 cmH2O Paw, while the vertical gradient in Lm decreased from 2.17 to 0.80 microns/cm. In the prone position, the vertical Ptp gradient increased from 0.06 cmH2O/cm at 0 cmH2O Paw to 0.35 cmH2O/cm at 15 cmH2O Paw, but there was no change in the vertical Lm gradient. In anesthetized paralyzed rabbits in supine and prone positions, we measured pleural liquid pressure directly at 0, 7, and 15 cmH2O Paw with dependent and nondependent rib capsules. Vertical Ptp gradients measured with rib capsules were similar to those estimated from the alveolar size measurements. Lung inflation during mechanical ventilation may reduce the vertical nonuniformities in lung expansion observed in the supine position, thereby improving gas exchange and the distribution of ventilation.  相似文献   

2.
We evaluated the effects of the different patterns of chest wall deformation that occur with different body positions and modes of breathing on regional lung deformation and ventilation. Using the parenchymal marker technique, we determined regional lung behavior during mechanical ventilation and spontaneous breathing in five anesthetized recumbent dogs. Regional lung behavior was related to the patterns of diaphragm motion estimated from X-ray projection images obtained at functional residual capacity (FRC) and end inspiration. Our results indicate that 1) in the prone and supine positions, FRC was larger during mechanical ventilation than during spontaneous breathing; 2) there were significant differences in the patterns of diaphragm motion and regional ventilation between mechanical ventilation and spontaneous breathing in both body positions; 3) in the supine position only, there was a vertical gradient in lung volume at FRC; 4) in both positions and for both modes of breathing, regional ventilation was nonlinearly related to changes in lobar and overall lung volumes; and 5) different patterns of diaphragm motion caused different sliding motions and differential rotations of upper and lower lobes. Our results are inconsistent with the classic model of regional ventilation, and we conclude that the distribution of ventilation is determined by a complex interaction of lung and chest wall shapes and by the motion of the lobes relative to each other, all of which help to minimize distortion of the lung parenchyma.  相似文献   

3.
The hydraulic pressure in the extrapleural parietal interstitium (Pepl) and in the pleural space over the costal side (Pliq) was measured in anesthetized spontaneously breathing supine adult mammals of increasing size (rats, dogs, and sheep) using saline-filled catheters and cannulas, respectively. From the Pliq and Pepl vs. lung height regressions it appears that in all species Pliq was significantly more subatmospheric than Pepl simultaneously measured at the same lung height. The vertical pleural liquid pressure gradient increased with size, amounting to -1, -0.69, and -0.44 cmH2O/cm in rats, dogs, and sheep, respectively. The vertical extrapleural liquid pressure gradient also increased with size, being -0.6, -0.52, and -0.33 cmH2O/cm in rats, dogs, and sheep, respectively. With increasing body size, the transpleural hydraulic pressure gradient (Ptp = Pepl - Pliq) at the level of the right atrium increased from 1.45 to 5.6 cmH2O going from rats to sheep. In all species Ptp increased, with lung height being greatest in the less dependent part of the pleural space.  相似文献   

4.
Prone posture increases cardiac output and improves pulmonary gas exchange. We hypothesized that, in the supine posture, greater compression of dependent lung limits regional blood flow. To test this, MRI-based measures of regional lung density, MRI arterial spin labeling quantification of pulmonary perfusion, and density-normalized perfusion were made in six healthy subjects. Measurements were made in both the prone and supine posture at functional residual capacity. Data were acquired in three nonoverlapping 15-mm sagittal slices covering most of the right lung: central, middle, and lateral, which were further divided into vertical zones: anterior, intermediate, and posterior. The density of the entire lung was not different between prone and supine, but the increase in lung density in the anterior lung with prone posture was less than the decrease in the posterior lung (change: +0.07 g/cm(3) anterior, -0.11 posterior; P < 0.0001), indicating greater compression of dependent lung in supine posture, principally in the central lung slice (P < 0.0001). Overall, density-normalized perfusion was significantly greater in prone posture (7.9 +/- 3.6 ml.min(-1).g(-1) prone, 5.1 +/- 1.8 supine, a 55% increase; P < 0.05) and showed the largest increase in the posterior lung as it became nondependent (change: +71% posterior, +58% intermediate, +31% anterior; P = 0.08), most marked in the central lung slice (P < 0.05). These data indicate that central posterior portions of the lung are more compressed in the supine posture, likely by the heart and adjacent structures, than are central anterior portions in the prone and that this limits regional perfusion in the supine posture.  相似文献   

5.
Using positron emission tomography (PET) and intravenously injected (13)N(2), we assessed the topographical distribution of pulmonary perfusion (Q) and ventilation (V) in six healthy, spontaneously breathing subjects in the supine and prone position. In this technique, the intrapulmonary distribution of (13)N(2), measured during a short apnea, is proportional to regional Q. After resumption of breathing, regional specific alveolar V (sVA, ventilation per unit of alveolar gas volume) can be calculated from the tracer washout rate. The PET scanner imaged 15 contiguous, 6-mm-thick, slices of lung. Vertical gradients of Q and sVA were computed by linear regression, and spatial heterogeneity was assessed from the squared coefficient of variation (CV(2)). Both CV and CV were corrected for the estimated contribution of random imaging noise. We found that 1) both Q and V had vertical gradients favoring dependent lung regions, 2) vertical gradients were similar in the supine and prone position and explained, on average, 24% of Q heterogeneity and 8% of V heterogeneity, 3) CV was similar in the supine and prone position, and 4) CV was lower in the prone position. We conclude that, in recumbent, spontaneously breathing humans, 1) vertical gradients favoring dependent lung regions explain a significant fraction of heterogeneity, especially of Q, and 2) although Q does not seem to be systematically more homogeneous in the prone position, differences in individual behaviors may make the prone position advantageous, in terms of V-to-Q matching, in selected subjects.  相似文献   

6.
We studied the vertical gradient in lung expansion in rabbits in the prone and supine body positions. Postmortem, we used videomicroscopy to measure the size of surface alveoli through transparent parietal pleural windows at dependent and nondependent sites separated in height by 2-3 cm at functional residual capacity (FRC). We compared the alveolar size measured in situ with that measured in the isolated lungs at different deflationary transpulmonary pressures to obtain transpulmonary pressure (pleural surface pressure) in situ. The vertical gradient in transpulmonary pressure averaged 0.48 +/- 0.16 (SD) cmH2O/cm height (n = 10) in the supine position and 0.022 +/- 0.014 (SD) cmH2O/cm (n = 5) in the prone position. In mechanically ventilated rabbits, we used the rib capsule technique to measure pleural liquid pressure at different heights of the chest in prone and supine positions. At FRC, the vertical gradient in pleural liquid pressure averaged 0.63 cmH2O/cm in the supine position and 0.091 cmH2O/cm in the prone position. The vertical gradients in pleural liquid pressure were all less than the hydrostatic value (1 cmH2O/cm), which indicates that pleural liquid is not generally in hydrostatic equilibrium. Both pleural surface pressure and pleural liquid pressure measurements show a greater vertical gradient in the supine than in the prone position. This suggests a close relationship between pleural surface pressure and pleural liquid pressure. Previous results in the dog and pony showed relatively high vertical gradients in the supine position and relatively small gradients in the prone position. This behavior is similar to the present results in rabbits. Thus the vertical gradient is independent of animal size and might be related to chest shape and weight of heart and abdominal contents.  相似文献   

7.
Gravity-independent inequality in pulmonary blood flow in humans   总被引:3,自引:0,他引:3  
Single-photon emission computerized tomography of the lung with 99mTc-labeled human albumin macroaggregates (99mTc-MAA) was used in six healthy subjects to study the three-dimensional distribution of pulmonary blood flow. 99mTc-MAA was injected while the subjects were resting in the supine position and holding their lung volume at normal end expiration. Tomography was performed on each subject from 120 projections of radioactivity in the lungs acquired with a rotating gamma camera. To minimize lung motion artifacts, the subjects were asked to hold their breath at end expiration during the 10-s duration of data acquisition in each projectional angle. Perfusion images of lung slices (11 mm thick) were reconstructed, and the radioactivity within each slice was expressed per unit lung volume of 3.7 X 3.7 X 11 mm. Perfusion images of a midcoronal slice from each subject manifested a concentric pattern of radioactivity that decreased significantly from the center to the periphery, suggesting that blood flow rate per unit lung volume was up to 10 times larger near the central region. This gradient in activity between the center and the periphery of the coronary slices was gravity independent as the subjects were supine. Images of sagittal slices from the middle of the right lung also manifested a similar pattern of concentric gradient in activity, with the vertical distribution (gravity related) almost comparable with the horizontal distribution (gravity independent). These results indicate that pulmonary blood flow in resting supine humans is spatially stratified with a marked central-to-peripheral gradient in all directions. It appears that zone 4 (reduced blood flow) is not a phenomenon limited to the dependent region of the lung as commonly thought but rather is a manifestation of this spatial distribution whereby blood flow is lowest in all peripheral regions of the lung.  相似文献   

8.
A recently developed method for quantitative assessment of regional lung ventilation was employed for the study of posture-dependent ventilation differences in rats. The measurement employed hyperpolarized (3)He MRI to detect the build-up of the signal intensity after increasing numbers of (3)He breaths, which allowed for computation of a regional ventilation parameter. A group of six anesthetized rats was studied in both supine and prone postures. Three-dimensional maps of the ventilation parameter were obtained with high spatial resolution (voxel volume approximately 2 mm(3)). Vertical (dorsal-ventral) gradients of the ventilation index, defined as the regional ventilation normalized by the average ventilation within the whole lung, were investigated. Variations in the regional distribution of the ventilation parameter, as well as of the ventilation index, could be detected, depending on the posture of the rats. In supine posture, ventilation was elevated in the dependent parts of the lungs, with a linear gradient of the ventilation index of -0.11 +/- 0.03 cm(-1). In prone posture, the distribution of ventilation was more uniform, with a significantly (P < 0.001) smaller gradient of the ventilation index of -0.01 +/- 0.02 cm(-1). It is concluded that the (3)He MRI-based method can detect and quantify regional ventilation gradients in animals as small as the rat and that these gradients depend on prone or supine posture of the animal.  相似文献   

9.
We have developed a new quantitative single-photon-emission computed tomography (SPECT) method that uses (113m)In-labeled albumin macroaggregates and Technegas ((99m)Tc) to estimate the distributions of regional ventilation and perfusion for the whole lung. The multiple inert-gas elimination technique (MIGET) and whole lung respiratory gas exchange were used as physiological evaluations of the SPECT method. Regional ventilation and perfusion were estimated by SPECT in nine healthy volunteers during awake, spontaneous breathing. Radiotracers were administered with subjects sitting upright, and SPECT images were acquired with subjects supine. Whole lung gas exchange of MIGET gases and arterial Po(2) and Pco(2) gases was predicted from estimates of regional ventilation and perfusion. We found a good agreement between measured and SPECT-predicted exchange of MIGET and respiratory gases. Correlations (r(2)) between SPECT-predicted and measured inert-gas excretions and retentions were 0.99. The method offers a new tool for measuring regional ventilation and perfusion in humans.  相似文献   

10.
Inflammation during mechanical ventilation is thought to depend on regional mechanical stress. This can be produced by concentration of stresses and cyclic recruitment in low-aeration dependent lung. Positron emission tomography (PET) with (18)F-fluorodeoxyglucose ((18)F-FDG) allows for noninvasive assessment of regional metabolic activity, an index of neutrophilic inflammation. We tested the hypothesis that, during mechanical ventilation, surfactant-depleted low-aeration lung regions present increased regional (18)F-FDG uptake suggestive of in vivo increased regional metabolic activity and inflammation. Sheep underwent unilateral saline lung lavage and were ventilated supine for 4 h (positive end-expiratory pressure = 10 cmH(2)O, tidal volume adjusted to plateau pressure = 30 cmH(2)O). We used PET scans of injected (13)N-nitrogen to compute regional perfusion and ventilation and injected (18)F-FDG to calculate (18)F-FDG uptake rate. Regional aeration was quantified with transmission scans. Whole lung (18)F-FDG uptake was approximately two times higher in lavaged than in nonlavaged lungs (2.9 ± 0.6 vs. 1.5 ± 0.3 10(-3)/min; P < 0.05). The increased (18)F-FDG uptake was topographically heterogeneous and highest in dependent low-aeration regions (gas fraction 10-50%, P < 0.001), even after correction for lung density and wet-to-dry lung ratios. (18)F-FDG uptake in low-aeration regions of lavaged lungs was higher than that in low-aeration regions of nonlavaged lungs (P < 0.05). This occurred despite lower perfusion and ventilation to dependent regions in lavaged than nonlavaged lungs (P < 0.001). In contrast, (18)F-FDG uptake in normally aerated regions was low and similar between lungs. Surfactant depletion produces increased and heterogeneously distributed pulmonary (18)F-FDG uptake after 4 h of supine mechanical ventilation. Metabolic activity is highest in poorly aerated dependent regions, suggesting local increased inflammation.  相似文献   

11.
The effects of body position and respiratory frequency (f) on regional gas transport during eucapnic conventional ventilation (CV) and high-frequency ventilation (HFV) were assessed from the washout of nitrogen 13 (13NN) using positron-emission tomography. In one protocol, six dogs were ventilated with CV or HFV at f = 6 Hz and tidal volume (VT) selected supine for eucapnia. A coronal cross section of the lung base was studied in the supine, prone, and right and left lateral decubitus positions. In a second protocol, six dogs were studied prone: apical and basal cross sections were studied in CV and in HFV with f = 3 and 9 Hz at eucapnic VT. Regional alveolar ventilation per unit of lung volume (spVr) was calculated for selected regions and analyzed for gravity-dependent cephalocaudal and right-to-left gradients. In both CV and HFV, nonuniformity in spVr was highest supine and lowest prone. In CV there were vertical gradients of spVr in all body positions: nondependent less ventilated than dependent regions, particularly in the supine position. In HFV there was a moderate vertical gradient in spVr in addition to a preferentially ventilated central region in all body positions. Overall lung spV was unaffected by body position in CV but in HFV was highest supine and lowest prone. Nonuniformity in eucapnic prone HFV was unaffected by f and always higher than in CV.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

12.
We propose a model to measure both regional ventilation (V) and perfusion (Q) in which the regional radiodensity (RD) in the lung during xenon (Xe) washin is a function of regional V (increasing RD) and Q (decreasing RD). We studied five anesthetized, paralyzed, mechanically ventilated, supine sheep. Four 2.5-mm-thick computed tomography (CT) images were simultaneously acquired immediately cephalad to the diaphragm at end inspiration for each breath during 3 min of Xe breathing. Observed changes in RD during Xe washin were used to determine regional V and Q. For 16 mm(3), Q displayed more variance than V: the coefficient of variance of Q (CV(Q)) = 1.58 +/- 0.23, the CV of V (CV(V)) = 0.46 +/- 0.07, and the ratio of CV(Q) to CV(V) = 3.5 +/- 1.1. CV(Q) (1.21 +/- 0.37) and the ratio of CV(Q) to CV(V) (2.4 +/- 1.2) were smaller at 1,000-mm(3) scale, but CV(V) (0.53 +/- 0.09) was not. V/Q distributions also displayed scale dependence: log SD of V and log SD of Q were 0.79 +/- 0.05 and 0.85 +/- 0.10 for 16-mm(3) and 0.69 +/- 0.20 and 0.67 +/- 0.10 for 1,000-mm(3) regions of lung, respectively. V and Q measurements made with CT and Xe also demonstrate vertically oriented and isogravitational heterogeneity, which are described using other methodologies. Sequential images acquired by CT during Xe breathing can be used to determine both regional V and Q noninvasively with high spatial resolution.  相似文献   

13.
Nasal expiratory positive airway pressure (nEPAP) delivered with a disposable device (Provent, Ventus Medical) has been shown to improve sleep-disordered breathing (SDB) in some subjects. Possible mechanisms of action are 1) increased functional residual capacity (FRC), producing tracheal traction and reducing upper airway (UA) collapsibility, and 2) passive dilatation of the airway by the expiratory pressure, carrying over into inspiration. Using MRI, we estimated change in FRC and ventilation, as well as UA cross-sectional area (CSA), in awake patients breathing on and off the nEPAP device. Ten patients with SDB underwent nocturnal polysomnography and MRI with and without nEPAP. Simultaneous images of the lung and UA were obtained at 6 images/s. Image sequences were obtained during mouth and nose breathing with and without the nEPAP device. The nEPAP device produced an end-expiratory pressure of 4-17 cmH(2)O. End-tidal Pco(2) rose from 39.7 ± 5.3 to 47.1 ± 6.0 Torr (P < 0.01). Lung volume changes were estimated from sagittal MRI of the right lung. Changes in UA CSA were calculated from transverse MRI at the level of the pharynx above the epiglottis. FRC determined by MRI was well correlated to FRC determined by N(2) washout (r = 0.76, P = 0.03). nEPAP resulted in a consistent increase in FRC (46 ± 29%, P < 0.001) and decrease in ventilation (50 ± 15%, P < 0.001), with no change in respiratory frequency. UA CSA at end expiration showed a trend to increase. During wakefulness, nEPAP caused significant hyperinflation, consistent with an increase in tracheal traction and a decrease in UA collapsibility. Direct imaging effects on the UA were less consistent, but there was a trend to dilatation. Finally, we showed significant hypoventilation and rise in Pco(2) during use of the nEPAP device during wakefulness and sleep. Thus, at least three mechanisms of action have the potential to contribute to the therapeutic effect of nEPAP on SDB.  相似文献   

14.
In vivo radioactive tracer and microsphere studies have differing conclusions as to the magnitude of the gravitational effect on the distribution of pulmonary blood flow. We hypothesized that some of the apparent vertical perfusion gradient in vivo is due to compression of dependent lung increasing local lung density and therefore perfusion/volume. To test this, six normal subjects underwent functional magnetic resonance imaging with arterial spin labeling during breath holding at functional residual capacity, and perfusion quantified in nonoverlapping 15 mm sagittal slices covering most of the right lung. Lung proton density was measured in the same slices using a short echo 2D-Fast Low-Angle SHot (FLASH) sequence. Mean perfusion was 1.7 +/- 0.6 ml x min(-1) x cm(-3) and was related to vertical height above the dependent lung (slope = -3%/cm, P < 0.0001). Lung density averaged 0.34 +/- 0.08 g/cm3 and was also related to vertical height (slope = -4.9%/cm, P < 0.0001). By contrast, when perfusion was normalized for regional lung density, the slope of the height-perfusion relationship was not significantly different from zero (P = 0.2). This suggests that in vivo variations in regional lung density affect the interpretation of vertical gradients in pulmonary blood flow and is consistent with a simple conceptual model: the lung behaves like a Slinky (Slinky is a registered trademark of Poof-Slinky Incorporated), a deformable spring distorting under its own weight. The greater density of lung tissue in the dependent regions of the lung is analogous to a greater number of coils in the dependent portion of the vertically oriented spring. This implies that measurements of perfusion in vivo will be influenced by density distributions and will differ from excised lungs where density gradients are reduced by processing.  相似文献   

15.
Obesity alters regional ventilation in lateral decubitus position   总被引:1,自引:0,他引:1  
Alterations of regional ventilation were determined as a function of body position in five morbidly obese subjects using 81mKr to assess ventilation (V) and 127Xe at equilibrium to determine lung volume (V). With subjects in seated and supine positions, the left lung contributed an average of 43% of the total V/V. When the apical-basal gradient within each lung was examined in subjects in the seated position, V/V was greatest in the dependent (basal) regions in half of the subjects, whereas the others showed greater V/V near the upper lung regions. All obese subjects preferentially ventilated the nondependent lung in both the left and right lateral decubitus positions. In a control group of three nonobese subjects, V/V was found to be equally distributed between left and right lungs in both the seated and supine positions. In contrast with the results in the obese group, V/V was slightly greater in the dependent lung in both lateral decubitus positions. Although the combination of 127Xe images and He-dilution measurement of functional residual capacity in the lateral decubitus positions indicated a reduction in the volume of the dependent lung of the obese when compared with values in the seated position, other factors affecting the mechanical function of either the diaphragm or the intercostal muscles could also have produced these positional alterations of ventilation.  相似文献   

16.
Effect of body position on regional diaphragm function in dogs   总被引:2,自引:0,他引:2  
The in situ lengths of muscle bundles of the crural and three regions of the costal diaphragm between origin and insertion were determined with a video roentgenographic technique in dogs. At total lung capacity (TLC) in both the prone and supine positions, the length of the diaphragm is not significantly different from the unstressed excised length, suggesting that the diaphragm is not under tension at TLC and that there is a hydrostatic gradient of pleural pressure on the diaphragmatic surface. Except for the ventral region of the costal diaphragm, which does not change length at lung volumes greater than 70% TLC, all other regions are stretched during passive deflations from TLC. Therefore below TLC the diaphragm is under passive tension and supports a transdiaphragmatic pressure (Pdi). The length of the diaphragm relative to its unstressed length is not uniform at functional residual capacity (FRC) and does not follow a strict vertical gradient that reverses when the animal is changed from the supine to the prone position. By inference, the length of muscle bundles is determined by factors other than the vertical gradient of Pdi. During mechanical ventilation, regional shortening is identical to the passive deflation length-volume relationship near FRC. Prone and supine FRC is the same, but the diaphragm is slightly shorter in the prone position. In both positions, during spontaneous ventilation there are no consistent differences in regional fractional shortening, despite regional differences in initial length relative to unstressed length.  相似文献   

17.
ECG-triggered computed tomography (CT) was used during passage of iodinated contrast to determine regional pulmonary blood flow (PBF) in anesthetized prone/supine dogs. PBF was evaluated as a function of height within the lung (supine and prone) as a function of various normalization methods: raw unit volume data (PBFraw) or PBF normalized to regional fraction air (PBFair), fractional non-air (PBFgm), or relative number of alveoli (PBFalv). The coefficient of variation of PBFraw, PBFair, PBFalv, and PBFgm ranged between 30 and 50% in both lungs and both body postures. The position of maximal flow along the height of the lung (MFP) was calculated for PBFraw, PBFair, PBFalv, and PBFgm. Only PBFgm showed a significantly different MFP height supine vs. prone (whole lung: 2.60 +/- 1.08 cm supine vs. 5.08 +/- 1.61 cm prone, P < 0.01). Mean slopes (ml/min/gm water content/cm) of PBFgm were steeper supine vs. prone in the right (RL) but not left lung (LL) (RL: -0.65 +/- 0.29 supine vs. -0.26 +/- 0.25 prone, P < 0.02; LL: -0.47 +/- 0.21 supine vs. -0.32 +/- 0.26 prone, P > 0.10). Mean slopes of PBFgm vs. vertical lung height were not different prone vs. supine above this vertical height of MFP (VMFP), but PBFgm slopes were steeper in the supine position below the VMFP in the RL. We conclude that PBFgm distribution was posture dependent in RL but not LL. Support of the heart may play a role. We demonstrate that normalization factors can lead to differing attributions of gravitational effects on PBF heterogeneity.  相似文献   

18.
Regional measurements of tissue isotope concentration, made using positron emission tomography (PET), allow tracer models to be used in a quantitative manner to provide topographic distributions of many structural and functional parameters, each derived for the same well-defined lung element. In this paper we describe a technique to measure regional ventilation-perfusion ratios (V/Q), in absolute units, by use of PET and the continuous intravenous infusion of an inert gas isotope, 13N, and report on measurements made in 12 normal subjects (4 smokers). Data were obtained from a single lung section (slice thickness, 1.7 cm full width at half-maximum response to a line source) at the level of the right ventricle in the supine posture during quiet breathing. For the 12 subjects, volume-weighted mean values of V/Q, averaged over individual right and left lung fields, ranged from 0.50 to 1.29. Analysis of these means showed no difference between lungs: right, 0.80 +/- 0.23 SD; left, 0.76 +/- 0.20 SD. Topographically, a systematic fall of V/Q in the ventrodorsal direction was observed in eight of the subjects (mean ventrodorsal difference 0.39, range 0.19-0.90), whereas two showed a clear increase toward dependent lung regions (range 0.16-0.26). Seven of the subjects with a falling ventrodorsal V/Q gradient also exhibited discrete regions of low V/Q at the dorsal lung border. We conclude that, in normal subjects, ventilation and perfusion are generally well matched in the supine posture, but isolated mismatching often occurs in dependent lung regions.  相似文献   

19.
During positive-pressure ventilation parenchymal deformation can be assessed as strain (volume increase above functional residual capacity) in response to stress (transpulmonary pressure). The aim of this study was to explore the relationship between stress and strain on the regional level using computed tomography in anesthetized healthy pigs in two postures and two patterns of breathing. Airway opening and esophageal pressures were used to calculate stress; change of gas content as assessed from computed tomography was used to calculate strain. Static stress-strain curves and dynamic strain-time curves were constructed, the latter during the inspiratory phase of volume and pressure-controlled ventilation, both in supine and prone position. The lung was divided into nondependent, intermediate, dependent, and central regions: their curves were modeled by exponential regression and examined for statistically significant differences. In all the examined regions, there were strong but different exponential relations between stress and strain. During mechanical ventilation, the end-inspiratory strain was higher in the dependent than in the nondependent regions. No differences between volume- and pressure-controlled ventilation were found. However, during volume control ventilation, prone positioning decreased the end-inspiratory strain of dependent regions and increased it in nondependent regions, resulting in reduced strain gradient. Strain is inhomogeneously distributed within the healthy lung. Prone positioning attenuates differences between dependent and nondependent regions. The regional effects of ventilatory mode and body positioning should be further explored in patients with acute lung injury.  相似文献   

20.
The main purpose of this study was to find out whether the dominant dorsal lung perfusion while supine changes to a dominant ventral lung perfusion while prone. Regional distribution of pulmonary blood flow was determined in 10 healthy volunteers. The subjects were studied in both prone and supine positions with and without lung distension caused by 10 cmH2O of continuous positive airway pressure (CPAP). Radiolabeled macroaggregates of albumin, rapidly trapped by pulmonary capillaries in proportion to blood flow, were injected intravenously. Tomographic gamma camera examinations (single-photon-emission computed tomography) were performed after injections in the different positions. All data acquisitions were made with the subject in the supine position. CPAP enhanced perfusion differences along the gravitational axis, which was more pronounced in the supine than prone position. Diaphragmatic sections of the lung had a more uniform pulmonary blood flow distribution in the prone than supine position during both normal and CPAP breathing. It was concluded that the dominant dorsal lung perfusion observed when the subjects were supine was not changed into a dominant ventral lung perfusion when the subjects were prone. Lung perfusion was more uniformly distributed in the prone compared with in the supine position, a difference that was more marked during total lung distension (CPAP) than during normal breathing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号