首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Herein, we reported for the first time one step procedure for the preparation of cytochrome c (cyt c)-poly (5-amino-2-napthalenesulfonic acid) (PANS) modified glassy carbon electrode by cyclic voltammetrically (CV). Hereafter, we called the above modified electrode as cyt c-PANS electrode. The presence of cyt c on modified electrode was investigated with electrochemical quartz crystal microbalance (EQCM), CV, and superoxide radicals reaction studies. The reaction between cyt c in the modified electrode and superoxide radicals in solution, was exemplified by cyclic voltammetric measurements. Surface morphology of the modified electrode was investigated by using atomic force microscopy (AFM). The modified electrode showed a pair of well defined redox peak in PBS solution, pH 6.7. The modified electrode utilized for electrocatalytic reduction as well as amperometric determination of hydrogen peroxide (H(2)O(2)). The detection limit and linear range for H(2)O(2) were 5 and 50 microM to 7 mM, respectively.  相似文献   

2.
A biosensor based on cytochrome c3 (cyt c3) has been introduced to detect and quantify superoxide radical (O2*-). Cyt c3, isolated from the sulfate-reducing bacterium (Desulfovibrio vulgaris Miyazaki F. strain), and its mutant were immobilized onto a conducting polymer coated electrodes by the covalent bonding with carbodiimide chemistry. The immobilization of cyt c3 was investigated with quartz crystal microbalance, electrochemical impedance spectroscopy, and cyclic voltammetric studies. The CVs recorded for cyt c3 and a mutant modified-electrodes showed a quasi-reversible behavior having the formal potential of about -471 and -476 mV (versus Ag/AgCl), respectively, in a 0.1M phosphate buffer solution (pH 7.0). The modified electrodes showed the surface controlled process and the electron transfer rate constants (ks) were evaluated to be 0.47 and 0.51 s(-1) for cyt c3 and mutant modified electrodes, respectively. A potential application of the cyt c3 modified electrode was evaluated by monitoring the bioelectrocatalytic response towards the O2*-. The hydrodynamic range of 0.2-2.7 micromole L(-1) and the detection limit of 0.05 micromole L(-1) were obtained.  相似文献   

3.
Di J  Bi S  Zhang M 《Biosensors & bioelectronics》2004,19(11):1479-1486
A third-generation biosensor for superoxide anion (O(2)*-) was developed based on superoxide dismutase (SOD) immobilized by thin silica-PVA sol-gel film on gold electrode surface. A rapid and direct electron transfer of SOD in the thin sol-gel film at the gold electrode was realized without any mediators or promoters. The characterization of the SOD electrodes showed a quasi-reversible electrochemical redox behavior with a formal potential of 80 + 5 mV (versus SCE) in 50 mmol l(-1) phosphate buffer solution (PBS), pH 7.0. The heterogeneous electron transfer rate constant was evaluated to be about 2.1s(-1). The anodic and cathodic transfer coefficients are 0.6 and 0.4, respectively. Based on biomolecular recognition for specific reactivity of SOD toward O(2)*- the SOD electrode was applied to a sensitive and selective measurement of O(2)*- with the low operation potential (-0.15 V versus SCE) in phosphate buffer solution, pH 7.0. The amperometric response was proportional to O(2)*- concentration in the range of 0.2-1.6 micromol l(-1) and the detection limit was 0.1 micromol l(-1) at a signal-to-noise ration of 3. The preparation of SOD electrode is easy and simple. The uniform porous structure of the silica-PVA sol-gel matrix results in a fast response rate of immobilized SOD and is very efficient for stabilizing the enzyme activity.  相似文献   

4.
A method for the electrochemical detection of antioxidants has been developed, which is based on a radical measurement with a cytochrome c modified electrode. A controlled enzymatic production system for superoxide radicals based on xanthine oxidase was used. The addition of antioxidants facilitated the decomposition of the radical in addition to the spontaneous dismutation. The steady-state of superoxide generation and decomposition was thus shifted to a new situation due to the higher decomposition rate after antioxidant addition. This resulted in a decreased current level at the electrode. Antioxidant activity could be quantified from the response of the sensor electrode by the percentage of the signal decrease. The 50% inhibition value (IC(50)) for different antioxidants was calculated and the antioxidant activity of numerous substances was compared. Thus, a hierarchy of superoxide radical scavenging abilities of flavonoids was established: flavanols>flavonols>flavones>flavonones>isoflavonones.  相似文献   

5.
The polyaniline (PANi)-Nafion composite film was prepared onto the ceramic plate by the cyclic voltammetry (CV) method with the various cycle numbers. When the PANi-Nafion/Au/ceramic plate with the preparing cycle number of 5 was as working electrode, the cathodic peak current was achieved as 84.0 microA in 60 mg dl(-1) NH4Cl buffer solution. On the other hand, the small cathodic peak currents for buffer solution in the presence of 60 mg dl(-1) LiOH, NaCl and KCl, respectively, were found with the same composite electrode as working electrode. The cathodic peak current decreased from 84.0 to 16.3 microA in the 60 mg dl(-1) NH4Cl buffer solution when the cycle number for preparing PANi-Nafion/Au/ceramic plate composite electrode with the CV method increased from 5 to 15. The enzyme of urease was immobilized onto the PANi-Nafion/Au/ceramic plate composite film by the electrochemical immobilization and the casting methods and used as sensing electrode to detect the concentration of urea in the buffer solution. The sensitivity of composite electrode immobilized with the casting method was greater than that of electrochemical immobilization method. The sensitivity and the detecting limit of the urea sensor were found to be 0.7 and 5.27 microA (mg dl(-1))(-1)cm(-2), as well as 6 and 0.3 mg dl(-1), respectively, when urease was immobilized by glutaraldehyde (GA) cross-linker and Nafion network, respectively.  相似文献   

6.
In this work a new original amperometric sensor for H(2)O(2) detection based on a Pt electrode modified with Te-microtubes was developed. Te-microtubes, synthesized by the simple thermal evaporation of Te powder, have a tubular structure with a hexagonal cross-section and are open ended. Modified electrode was prepared by direct drop casting of the mixture of Te-microtubes dispersed in ethanol on Pt surface. The spectroscopic characterization of synthesized Te-microtubes and Pt/Te-microtubes modified electrodes was performed by scanning electron microscopy (SEM), energy-dispersive X-rays microanalysis (EDX), X-ray diffraction analysis (XRD) and X-ray photoelectron spectroscopy (XPS). Moreover a complete electrochemical characterization of the new composite material Pt/Te-microtubes was performed by cyclic voltammetry (CV) and cronoamperometry (CA) in phosphate buffer solution (PBS) at pH 7. Electrochemical experiments showed that the presence of Te-microtubes on modified electrode was responsible for an increment of both cathodic and anodic currents in presence of H(2)O(2) with respect to bare Pt. Specifically, data collected from amperometric experiments at -150 mV vs. SCE in batch and -200 mV vs. SCE in flow injection analysis (FIA) experiments show a remarkable increment of the cathodic current. The electrochemical performances of tested sensors make them suitable for the quantitative determination of H(2)O(2) substrate both in batch and in FIA.  相似文献   

7.
为了基于羧基化石墨烯/半胱胺修饰金电极建立更为先进的多巴胺生物传感器,以定量检测儿茶酚胺类神经递质多巴胺,利用自组装技术将半胱胺修饰于金电极上,再利用1-乙基-\[3-二甲基氨基丙基\]碳酰二亚胺盐酸化物/N-羟基琥珀酰亚胺(EDC/NHS)交联剂将羧基化石墨烯固定在修饰后的金电极上制成多巴胺电化学传感器。先对修饰电极进行表征以检验其灵敏度,再利用循环伏安法研究该电极在多巴胺溶液中的电化学行为,包括检测条件的优化和传感器性能的测定。修饰电极表征结果表明,羧基化石墨烯/半胱胺修饰金电极提高了电极传递电子的能力,具有较高的灵敏度。经单因素实验得出,最佳检测条件为利用pH 6.00的0.30 mol·L-1磷酸盐缓冲溶液(PBS)配制多巴胺溶液,扫描速率设定为200 mV·s-1。在最佳检测条件下,制备的多巴胺电化学传感器电流的大小随着多巴胺浓度的增大而增大,在1.0×10-3~3.5×10-3 mol·L-1范围内呈现良好的线性关系,线性回归方程为I=8.120 6C+7.017,相关系数R2为0.999 5。且该传感器精密度好,稳定性强,具有一定的抗干扰能力。研究结果为药物盐酸多巴胺注射液中多巴胺含量测定提供了支撑。  相似文献   

8.
Oxidative alteration of mitochondrial cytochrome c (cyt c) has been linked to disease pathophysiology and is one of the causative factors for pro-apoptotic events. Hydrogen peroxide induces a short-lived cyt c-derived tyrosyl radical as detected by the electron spin resonance (ESR) spin-trapping technique. This investigation was undertaken to characterize the fate and consequences of the cyt c-derived tyrosyl radical. The direct ESR spectrum from the reaction of cyt c with H(2)O(2) revealed a single-line signal with a line width of approximately 10 G. The detected ESR signal could be prevented by pretreatment of cyt c with iodination, implying that the tyrosine residue of cyt c was involved. The ESR signal can be enhanced and stabilized by a divalent metal ion such as Zn(2+), indicating the formation of the protein tyrosine ortho-semiquinone radical (ToQ.). The production of cyt c-derived ToQ. is inhibited by the spin trap, 2-methyl-2-nitrosopropane (MNP), suggesting the participation of tyrosyl radical in the formation of the ortho-semiquinone radical. The endothelium relaxant factor nitric oxide is well known to mediate mitochondrial respiration and apoptosis. The consumption of NO by cyt c was enhanced by addition of H(2)O(2) as verified by inhibition electrochemical detection using an NO electrode. The rate of NO consumption in the system containing cyt c/NO/H(2)O(2) was decreased by the spin traps 5,5-dimethyl pyrroline N-oxide and MNP, suggesting NO trapping of the cyt c-derived tyrosyl radical. The above result was further confirmed by NO quenching of the ESR signal of the MNP adduct of cyt c tyrosyl radical. Immunoblotting analysis of cyt c after exposure to NO in the presence of H(2)O(2) revealed the formation of 3-nitrotyrosine. The addition of superoxide dismutase did not change the cyt c nitration, indicating that it is peroxynitrite-independent. The results of this study may provide useful information in understanding the interconnection among cyt c, H(2)O(2), NO, and apoptosis.  相似文献   

9.
Polyaniline protected gold nanoparticles (PPAuNPs) were electrophoretically deposited onto a gold electrode, and utilized to fabricate an electrochemical cortisol biosensor. Cortisol specific monoclonal antibody (C-Mab) was covalently immobilized onto the surface of a PPAuNP/Au electrode using N-ethyl-N'-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide (EDC/NHS) chemistry. BSA was employed for blocking nonspecific adsorption on the electrode surface. PPAuNP formation and BSA/C-Mab/PPAuNP/Au electrode fabrication were characterized using transmission electron microscopy, atomic force microscopy and electrochemical impedance techniques, respectively. Cyclic voltammetry and differential pulse voltammetric techniques were used to determine the cortisol concentration in a phosphate buffer saline (PBS) solution. Results confirmed that the PPAuNP based electrode was stable during repeated scans and exhibited repeatable redox peaks. Further, the BSA/C-Mab/PPAuNP/Au electrode in the PBS buffer accurately detected cortisol in the range of 1 pM-100 nM with a sensitivity of 1.63 μAM(-1). The biosensor was found to be selective against BSA and 17-α-hydroxy progesterone. This research establishes the feasibility of using a PPAuNP based matrix for a label and mediator free electrochemical biosensor for cortisol, a stress biomarker.  相似文献   

10.
Stable films of didodecyldimethylammonium bromide (DDAB, a synthetic lipid) and horseradish peroxidase (HRP) were made by casting the mixture of the aqueous vesicle of DDAB and HRP onto the glassy carbon (GC) electrode. The direct electron transfer between electrode and HRP immobilized in lipid film has been demonstrated. The lipid films were used to supply a biological environment resembling biomembrane on the surface of the electrode. A pair of redox peaks attributed to the direct redox reaction of HRP were observed in the phosphate buffer solution (pH 5.5). The cathodic peak current increased dramatically while anodic peak decreased by addition of small amount H(2)O(2). The pH effect on amperometric response to H(2)O(2) was studied. The biosensor also exhibited fast response (5 s), good stability and reproducibility.  相似文献   

11.
An amperometric dimethyl sulfoxide (DMSO) sensor was constructed based on DMSO reductase (DMSO-R). DMSO-R from Rhodobacter sphaeroides f. sp. denitrificans was immobilized by BSA-glutaraldehyde cross-linking at the surface of a glassy carbon electrode. Mediators were added to the sample solution in a free form. Several mediators (methyl viologen (MV), benzyl viologen (BV), neutral red (NR), safranin T (ST), FMN, phenazine methosulfate (PMS)), which can donate electrons to DMSO-R, were examined with the DMSO-R immobilized electrode. Among them MV was selected as a model mediator because of its wide linear response range and fast response time. The response current was effected by the measurement temperature but hardly effected by the pH of the sample solution. The response current was increased with the measurement temperature up to 50 degrees C. A response current was observed at 1 microM DMSO and the response time was 20 s under the optimum conditions. The response was observed for approximately 2 weeks. By the reduction of Schiff base in the cross-linking layer the response range became narrower but most of the response current was retained at 300 microM of DMSO for more than 5 weeks.  相似文献   

12.
Cytochrome c oxidase (CcO) from Paracoccus denitrificans was immobilized in a strict orientation via a his-tag attached to subunit I on a gold film and reconstituted in situ into a protein-tethered bilayer lipid membrane. In this orientation, the cytochrome c (cyt c) binding site is directed away from the electrode pointing to the outer side of the protein-tethered bilayer lipid membrane architecture. The CcO can thus be activated by cyt c under aerobic conditions. Catalytic activity was monitored by impedance spectroscopy, as well as cyclic voltammetry. Cathodic and anodic currents of the CcO with cyt c added to the bulk solution were shown to increase under aerobic compared to anaerobic conditions. Catalytic activity was considered in terms of repeated electrochemical oxidation/reduction of the CcO/cyt c complex in the presence of oxygen. The communication of cyt c bound to the CcO with the electrode is discussed in terms of a hopping mechanism through the redox sites of the enzyme. Simulations supporting this hypothesis are included.  相似文献   

13.
A photoelectrochemical signal chain sensitive to the presence of superoxide radicals was developed on the basis of CdSe/ZnS quantum dots which were immobilized on gold electrodes using a dithiol compound. The conditions of photo current generation under illumination have been characterized with respect to the dependence on the applied electrode potential, the wavelength of the light beam and the stability of the measurement. Because of photoexcitation electron-hole pair generation is enforced in the nanoparticles enhancing the conductivity of the quantum dot layer. This was independently verified by impedance measurements. In order to observe direct electron transfer with the redox protein cytochrome c different surface modifications of the quantum dots were investigated-mercaptopropionic acid, mercaptosuccinic acid and mercaptopyridine. Varying superoxide concentrations in solution can be detected by an enhanced conversion of superoxide-reduced cytochrome c and thus by an enhanced photo current at the quantum dot modified electrode. The electrode was found to be sensitive to higher nanomolar concentrations of the radical.  相似文献   

14.
The electrocatalytic oxidation of two orally administered iron chelator drugs (deferiprone, CP20, and deferasirox, ICL670) was investigated on a nickel oxyhydroxide-modified nickel electrode in alkaline solution. The oxidation process involved and its kinetics were investigated using cyclic voltammetry, chronoamperometry, and electrochemical impedance spectroscopy techniques, as well as steady-state polarization measurements. Voltammetric studies indicated that in the presence of the drugs under study, the anodic peak current of low-valence nickel species increased, followed by a decrease in the corresponding cathodic current. This result indicates that the drugs were oxidized via oxyhydroxide species immobilized on the electrode surface via an EC' mechanism. A mechanism based on the electrochemical generation of Ni(III) active sites and their subsequent consumption by the drugs in question was also investigated. The corresponding rate law under the control of charge transfer was developed, and kinetic parameters were derived. In this context, the charge-transfer resistance accessible both theoretically and through impedancemetry was used as a criterion. The rate constants of the catalytic oxidation of the drugs and the electron-transfer coefficients are reported. A sensitive, simple, and time-saving amperometric procedure was developed for the analysis of deferasirox and deferiprone, with detection limits of 28 and 19 microM, respectively. The electrode was used for the direct assay of deferasirox and deferiprone tablets.  相似文献   

15.
We demonstrate the construction of glucose sensors employing pyrroloquinoline quinone (PQQ) glucose dehydrogenase (PQQGDH) from Acinetobacter calcoaceticus and glucose oxidase (GOD) from Aspergillus nigar coupled with Escherichia coli soluble cytochrome b(562) (cyt b(562)) as electron acceptor. PQQGDH and GOD do not show direct electrochemical recycling of the prosthetic group at the electrode surface leading to a corresponding current signal. We constructed PQQGDH and GOD electrodes co-immobilized with 100-fold molar excess of cyt b(562) and investigated the electrochemical properties without synthetic electron mediators. PQQGDH/cyt b(562) and GOD/cyt b(562) electrodes both responded well to glucose whereas no current increase was observed from the electrode immobilizing enzyme alone. The detection limits for the PQQGDH/cyt b(562) and GOD/cyt b(562) electrodes were 0.1 and 0.8 mM, respectively, and their linearity extended to over 2 and 9 mM, respectively. These results demonstrate that a sensor system can be constructed without a synthetic electron mediator by using a natural electron acceptor. Furthermore, we have demonstrated the potential application of cyt b(562) in direct electron transfer type sensor systems with oxidoreductases whose quaternary structure do not contain any electron transfer subunit.  相似文献   

16.
A new type miniaturized glucose sensor with good selectivity and stable current response has been developed. The structure consists of a recessed rectangular microfabricated platinum electrode, inner layer of two electropolymerized nonconducting films, and outer bilayer of poly(tetrafluoroethylene) (Teflon) and polyurethane (PU) films. Glucose oxidase (GOx) is entrapped during the electropolymerization of a poly(m-phenylenediamine) (PMPD) film in an acetate buffer (AB) solution, on which a highly interference-resistive PMPD film is deposited in a phosphate buffered saline (PBS) solution. The second PMPD film causes no significant decrease in accessibility of glucose to GOx. The inner layer maintains less than 1% permeability to acetaminophen for 12 days. The fairly adhesive outer layer allows stable current response. Due to high permeability, the information about enzyme activity can be obtained without serious error in spite of outer layer intervening between enzymes and solution. The apparent Michaelis-Menten constant and the maximum steady-state current density were 24 mM and 80 microA cm(-2), respectively.  相似文献   

17.
A novel hydrogen peroxide biosensor was fabricated by using a DNA-Cu(II) complex as a novel electrocatalyst for the reduction of hydrogen peroxide (H2O2). A polyion complex (PIC) membrane composed of DNA and poly(allylamine) (PAA) functioned as a support matrix for immobilization of electrocatalytic element-copper ion. The circular dichroism (CD) spectrum of the DNA-Cu(II)/PAA membrane in wet state showed that the DNA exists in B-like form within the membrane. Electrochemical measurements of the DNA-Cu(II)/PAA membrane-modified glassy carbon (GC) electrode revealed that the copper ion embedded in the DNA/PAA layer exhibits good electrochemical behaviors, and the electrochemical rate constant between the immobilized copper ion and the GC electrode surface was estimated to be 26.4 s(-1). The resulting DNA-Cu(II)/PAA/GC electrode showed an excellent electrocatalytic activity for the H2O2 reduction. The sensitivity of the sensor for the determination of H2O2 was affected by the amount of each component, such as copper ion, DNA and PAA in the DNA-Cu(II)/PAA membrane. Effects of applied potential, pH, temperature, ionic strength and buffer concentrations upon the response currents of the sensor were also investigated for an optimum analytical performance. Even in the presence of dissolved oxygen, the sensor exhibited highly sensitive and rapid (response time, less than 5 s) response to H2O2. The steady-state cathodic current responses of the sensor obtained at -0.2 V versus Ag/AgCl in air-saturated 50 mM phosphate buffer (pH 5.0) increased linearly up to 135 microM with the detection limit of 50 nM. Interference by ascorbic acid and uric acid due to the reduction of Cu(II) was effectively cancelled by further modification of outermost layer of polyion complex film. In addition, the sensor exhibited good reproducibility and stability.  相似文献   

18.
Direct electrochemistry and thermal stability of hemoglobin (Hb) immobilized on a nanometer-sized zirconium dioxide (ZrO2) modified pyrolytic graphite (PG) electrode were studied. The immobilized Hb displayed a couple of stable and well-defined redox peaks with an electron transfer rate constant of (7.90 +/- 0.93)s(-1) and a formal potential of -0.361 V (-0.12 V versus NHE) in 0.1M pH 7.0 PBS. Both nanometer-sized ZrO2 and dimethyl sulfoxide (DMSO) could accelerate the electron transfer between Hb and the electrode. Spectroscopy analysis of the Hb/ZrO2/DMSO film showed that the immobilized Hb could retain its natural structure. This modified electrode showed a high thermal stability up to 74 degrees C and an electrocatalytic activity to the reduction of hydrogen peroxide (H2O2) without the aid of an electron mediator. The electrocatalytic response showed a linear dependence on the H2O2 concentration ranging from 1.5 to 30.2 microM with a detection limit of 0.14 microM at 3sigma. The apparent Michaelis-Menten constant KMapp for H2O2 sensor was estimated to be (0.31 +/- 0.02) mM, showing a high affinity.  相似文献   

19.
The direct electrochemical redox reaction of bovine erythrocyte copper--zinc superoxide dismutase (Cu(2)Zn(2)SOD) was clearly observed at a gold electrode modified with a self-assembled monolayer (SAM) of cysteine in phosphate buffer solution containing SOD, although its reaction could not be observed at the bare electrode. In this case, SOD was found to be stably confined on the SAM of cysteine and the redox response could be observed even when the cysteine-SAM electrode used in the SOD solution was transferred to the pure electrolyte solution containing no SOD, suggesting the permanent binding of SOD via the SAM of cysteine on the electrode surface. The electrode reaction of the SOD confined on the cysteine-SAM electrode was found to be quasi-reversible with the formal potential of 65 +/- 3 mV vs. Ag/AgCl and its kinetic parameters were estimated: the electron transfer rate constant k(s) is 1.2 +/- 0.2 s(-1) and the anodic (alpha(a)) and cathodic (alpha(c)) transfer coefficients are 0.39 +/- 0.02 and 0.61 +/- 0.02, respectively. The assignment of the redox peak of SOD at the cysteine-SAM modified electrode could be sufficiently carried out using the native SOD (Cu(2)Zn(2)SOD), its Cu- or Zn-free derivatives (E(2)Zn(2)SOD and Cu(2)E(2)SOD, E designates an empty site) and the SOD reconstituted from E(2)Zn(2)SOD and Cu(2+). The Cu complex moiety, the active site for the enzymatic dismutation of the superoxide ion, was characterized to be also the electroactive site of SOD. In addition, we found that the SOD confined on the electrode can be expected to possess its inherent enzymatic activity for dismutation of the superoxide ion.  相似文献   

20.
The determination of bile acid concentration in urine is useful for the screening and diagnosis of various hepatobiliary diseases. Currently, there is no concise method to determine bile acid concentration in urine. This study describes a bile acid biosensor fabricated by electrochemical technique for urinalysis. The micro-planar electrodes employed for the study consisted of a working electrode (platinum), a counter electrode (platinum) and a reference electrode (silver/silver chloride (Ag/AgCl)). The sensor chip was coated with Nafion using a spin-coater in order to both eliminate many interference species in urine and achieve long-term stability of the reference electrode. Nafion coating allowed the sensor chip to prevent the electrode reaction from interference species in urine, because it is charged negative strongly (Nafion contains sulfonic acid group). Three enzymes (bile acid sulfate sulfatase: BSS, beta-hydroxysteroid dehydrogenase: beta-HSD, and NADH oxidase: NHO) were immobilized by glutaraldehyde (GA: cross-linker) onto the sensor chip, because the immobilization of enzymes by GA is simple and commonly carried out. The sensor chip was able to detect bile acid in buffer solution. The optimum enzyme ratio immobilized onto the sensor chip was BSS:beta-HSD:NHO=4:4:20 U/1 chip. There was a relationship between the concentration of bile acid and the response current value. The dynamic range of the sensor chip was 2-100 microM for bile acid. Additionally, bile acid in the urine specimen could be detected using this bile acid biosensor. We present a simple and rapid bile acid biosensor with high sensitivity and high reproducibility.  相似文献   