首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The distribution of sugar chains on tissue sections of the rat vomeronasal epithelium, and the adhesive force between the sugar and its specific lectin were examined with an atomic force microscope (AFM). AFM tips were modified with a lectin, Vicia villosa agglutinin, which recognizes terminal N-acetyl-D-galactosamine (GalNAc). When a modified tip scanned the luminal surface of the sensory epithelium, adhesive interactions between the tip and the sample surface were observed. The final rupture force was calculated to be approximately 50 pN based on the spring constant of the AFM cantilever. Distribution patterns of sugar chains obtained from the force mapping image were very similar to those observed using fluorescence-labeled lectin staining. AFM also revealed distribution patterns of sugar chains at a higher resolution than those obtained with fluorescence microscopy. Most of the adhesive interactions disappeared when the scanning solution contained 1 mM GaINAc. The adhesive interactions were restored by removing the sugar from the solution. Findings suggest that the adhesion force observed are related to the binding force between the lectin and the sugars distributed across the vomeronasal epithelium.  相似文献   

2.
Cooperative (simultaneous) breakage of multiple adhesive bonds has been proposed as a mechanism for enhanced binding strength between adhesion molecules on apposing cell surfaces. In this report, we used the atomic force microscopy (AFM) to study how changes in binding affinity and separation rate of force-induced ligand-receptor dissociation affect binding cooperativity. The AFM force measurements were carried out using (strept)avidin-functionalized cantilever tips and biotinylated agarose beads under conditions where multiple (strept)avidin-biotin linkages were formed following surface contact. At slow surface separation of the AFM cantilever from the bead's surface, the (strept)avidin-biotin linkages appeared to rupture sequentially. Increasing the separation rate from 210 to 1950 nm/s led to a linear increase in the average rupture force. Moreover, force histograms revealed a quantized force distribution that shifted toward higher values with increasing separation rate. In measurements of streptavidin-iminobiotin adhesion, the force distribution also shifted toward higher values when the buffer was adjusted to a higher pH to raise the binding affinity. Together, these results demonstrate that the cooperativity of ligand-receptor bonds is significantly enhanced by increases in surface separation rate and/or binding affinity.  相似文献   

3.
There is a need in current atomic force microscopy (AFM) molecular recognition studies for generic methods for the stable, functional attachment of proteins on tips and solid supports. In the last few years, the site-directed nitrilotriacetic acid (NTA)-polyhistidine (Hisn) system has been increasingly used towards this goal. Yet, a crucial question in this context is whether the NTA-Hisn bond is sufficiently strong for ensuring stable protein immobilization during force spectroscopy measurements. Here, we measured the forces between AFM tips modified with NTA-terminated alkanethiols and solid supports functionalized with His6-Gly-Cys peptides in the presence of Ni2+. The force histogram obtained at a loading rate of 6600 pN s(-1) showed three maxima at rupture forces of 153 +/- 57 pN, 316 +/- 50 pN and 468 +/- 44 pN, that we attribute primarily to monovalent and multivalent interactions between a single His6 moiety and one, two and three NTA groups, respectively. The measured forces are well above the 50-100 pN unbinding forces typically observed by AFM for receptor-ligand pairs. The plot of adhesion force versus log (loading rate) revealed a linear regime, from which we deduced a kinetic off-rate constant of dissociation, k(off) approximately 0.07 s(-1). This value is in the range of that estimated for the multivalent interaction involving two NTA, using fluorescence measurements, and may account for an increased binding stability of the NTA-His6 bond. We conclude that the NTA-His6 system is a powerful, well-suited platform for the stable, oriented immobilization of proteins in AFM single-molecule studies.  相似文献   

4.
Specific molecular recognition events, detected by atomic force microscopy (AFM), so far lack the detailed topographical information that is usually observed in AFM. We have modified our AFM such that, in combination with a recently developed method to measure antibody-antigen recognition on the single molecular level (Hinterdorfer, P., W. Baumgartner, H. J. Gruber, K. Schilcher, and H. Schindler, Proc. Natl. Acad. Sci. USA 93:3477-3481 (1996)), it allows imaging of a submonolayer of intercellular adhesion molecule-1 (ICAM-1) in adhesion mode. We demonstrate that for the first time the resolution of the topographical image in adhesion mode is only limited by tip convolution and thus comparable to tapping mode images. This is demonstrated by imaging of individual ICAM-1 antigens in both the tapping mode and the adhesion mode. The contrast in the adhesion image that was measured simultaneously with the topography is caused by recognition between individual antibody-antigen pairs. By comparing the high-resolution height image with the adhesion image, it is possible to show that specific molecular recognition is highly correlated with topography. The stability of the improved microscope enabled imaging with forces as low as 100 pN and ultrafast scan speed of 22 force curves per second. The analysis of force curves showed that reproducible unbinding events on subsequent scan lines could be measured.  相似文献   

5.
To determine whether platelet adhesion to surfaces coated with the matrix protein osteopontin requires an agonist-induced increase in the affinity of the integrin alpha v beta 3 for this ligand, we used laser tweezers to measure the rupture force between single alpha v beta 3 molecules on the platelet surface and osteopontin-coated beads. Virtually all platelets stimulated with 10 microM ADP bound strongly to osteopontin, producing rupture forces as great as 100 piconewtons (pN) with a peak at 45-50 pN. By contrast, 90% of unstimulated, resting non-reactive platelets bound weakly to osteopontin, with rupture forces rarely exceeding 30-35 pN. However, approximately 10% of unstimulated platelets, resting reactive platelets, exhibited rupture force distributions similar to stimulated platelets. Moreover, ADP stimulation resulted in a 12-fold increase in the probability of detecting rupture forces >30 pN compared with resting non-reactive platelets. Pre-incubating stimulated platelets with the inhibitory prostaglandin E1, a cyclic RGD peptide, the monoclonal antibody abciximab, or the alpha v beta 3-specific cyclic peptide XJ735 returned force histograms to those of non-reactive platelets. These experiments demonstrate that ADP stimulation increases the strength of the interaction between platelet alpha v beta 3 and osteopontin. Furthermore, they indicate that platelet adhesion to osteopontin-coated surfaces requires an agonist-induced exposure of alpha v beta 3-binding sites for this ligand.  相似文献   

6.
Membrane tension underlies a range of cell physiological processes. Strong adhesion of the simple red cell is used as a simple model of a spread cell with a finite membrane tension-a state which proves useful for studies of both membrane rupture kinetics and atomic force microscopy (AFM) probing of native structure. In agreement with theories of strong adhesion, the cell takes the form of a spherical cap on a substrate densely coated with poly-L-lysine. The spreading-induced tension, sigma, in the membrane is approximately 1 mN/m, which leads to rupture over many minutes; and sigma is estimated from comparable rupture times in separate micropipette aspiration experiments. Under the sharpened tip of an AFM probe, nano-Newton impingement forces (10-30 nN) are needed to penetrate the tensed erythrocyte membrane, and these forces increase exponentially with tip velocity ( approximately nm/ms). We use the results to clarify how tapping-mode AFM imaging works at high enough tip velocities to avoid rupturing the membrane while progressively compressing it to a approximately 20-nm steric core of lipid and protein. We also demonstrate novel, reproducible AFM imaging of tension-supported membranes in physiological buffer, and we describe a stable, distended network consistent with the spectrin cytoskeleton. Additionally, slow retraction of the AFM tip from the tensed membrane yields tether-extended, multipeak sawtooth patterns of average force approximately 200 pN. In sum we show how adhesive tensioning of the red cell can be used to gain novel insights into native membrane dynamics and structure.  相似文献   

7.
Using atomic force microscopy (AFM) we performed dynamic force measurements of the adhesive forces in two model systems: avidin-biotin and streptavidin-biotin. In our experiments we used glutaraldehyde for immobilization of (strept)avidin on the tip and biotin on the sample surface. Such interface layers are more rigid than those usually reported in the literature for AFM studies, when (strept)avidin is coupled with biotinylated bovine albumin and biotin with agarose polymers. We determined the dependence of the rupture forces of avidin-biotin and streptavidin-biotin bonds in the range 300-9600 pN/s. The slope of a semilogarithmic plot of this relation changes at about 1700 pN/s. The existence of two different regimes indicates the presence of two activation barriers of these complexes during the dissociation process. The dissociation rates and activation energy barriers, calculated from the Bell model, for the avidin-biotin and streptavidin-biotin interactions are similar to each other for loading rates > 1700 pN/s but they are different from each other for loading rates < 1700 pN/s. In the latter case, the dissociation rates show a higher stability of the avidin-biotin complex than the streptavidin-biotin complex due to a larger outer activation barrier of 0.8 k(B)T. The bond-rupture force is about 20 pN higher for the avidin-biotin pair than for the streptavidin-biotin pair for loading rates < 1700 pN/s. These two experimental observations are in agreement with the known structural differences between the biotin binding pocket of avidin and of streptavidin.  相似文献   

8.
《Journal of biomechanics》2014,47(16):3855-3861
Single-cell force spectroscopy (SCFS), an atomic force microscopy (AFM)-based assay, enables quantitative study of cell adhesion while maintaining the native state of surface receptors in physiological conditions. Human healthy and pathological red blood cells (RBCs) express a large number of surface proteins which mediate cell–cell interactions, or cell adhesion to the extracellular matrix. In particular, RBCs adhere with high affinity to subendothelial matrix laminin via the basal cell adhesion molecule and Lutheran protein (BCAM/Lu). Here, we established SCFS as an in vitro technique to study human RBC adhesion at baseline and following biochemical treatment. Using blood obtained from healthy human subjects, we recorded adhesion forces from single RBCs attached to AFM cantilevers as the cell was pulled-off of substrates coated with laminin protein. We found that an increase in the overall cell adhesion measured via SCFS is correlated with an increase in the resultant total force measured on 1 µm2 areas of the RBC membrane. Further, we showed that SCFS can detect significant changes in the adhesive response of RBCs to modulation of the cyclic adenosine monophosphate (cAMP) and protein kinase A (PKA) pathway. Lastly, we identified variability in the RBC adhesion force to laminin amongst the human subjects, suggesting that RBCs maintain diverse levels of active BCAM/Lu adhesion receptors. By using single-cell measurements, we established a powerful new method for the quantitative measurement of single RBC adhesion with specific receptor-mediated binding.  相似文献   

9.
Atomic force microscopy (AFM) can be used to probe the mechanics of molecular recognition between surfaces. In the application known as "chemical force" microscopy (CFM), a chemically modified AFM tip probes a surface through chemical recognition. When modified with a biological ligand or receptor, the AFM tip can discriminate between its biological binding partner and other molecules on a heterogeneous substrate. The strength of the interaction between the modified tip and the substrate is governed by the molecular affinity. We have used CFM to probe the interactions between short segments of single-strand DNA (oligonucleotides). First, a latex microparticle was modified with the sequence 3'-CAGTTCTACGATGGCAAGTC and epoxied to a standard AFM cantilever. This DNA-modified probe was then used to scan substrates containing the complementary sequence 5'-GTCAAGATGCTACCGTTCAG. These substrates consisted of micron-scale, patterned arrays of one or more distinct oligonucleotides. A strong friction interaction was measured between the modified tip and both elements of surface-bound DNA. Complementary oligonucleotides exhibited a stronger friction than the noncomplementary sequences within the patterned array. The friction force correlated with the measured strength of adhesion (rupture force) for the tip- and array-bound oligonucleotides. This result is consistent with the formation of a greater number of hydrogen bonds for the complementary sequence, suggesting that the friction arises from a sequence-specific interaction (hybridization) of the tip and surface DNA.  相似文献   

10.
Protein nanoarrays containing integrin alphavbeta3 or BSA were fabricated on ProLinker-coated Au surface by dip-pen nanolithography (DPN). An atomic force microscope (AFM) tip coated with ProLinker was modified by vitronectin. We measured the interaction force between nanoarrayed integrin alphavbeta3 or BSA and immobilized vitronectin on the cantilever tip by employing tethering-unbinding method. The unbinding force between integrin alphavbeta3 and vitronectin (1087+/-62 pN) was much higher than that of between BSA and vitronectin (643+/-74 pN). These results demonstrate that one can distinguish a specific protein interaction from non-specific interactions by means of force measurement on the molecular interactions between the nanoarrayed protein and its interacting protein on the AFM tip.  相似文献   

11.
Cross-talk between cells and the extracellular matrix is critically influenced by the mechanical properties of cell surface receptor-ligand interactions; these interactions are especially well defined and regulated in cells capable of dynamically modifying their matrix environment. In this study, attention was focused on osteoclasts, which are absolutely dependent on integrin extracellular matrix receptors in order to degrade bone; other bone cells, osteoblasts, were used for comparison. Integrin binding forces were measured in intact cells by atomic force microscopy (AFM) for several RGD-containing (Arg-Gly-Asp) ligands and ranged from 32 to 97 picoNewtons (pN); they were found to be cell and amino acid sequence specific, saturatable and sensitive to the pH and divalent cation composition of the cellular culture medium. In contrast to short linear RGD hexapeptides, larger peptides and proteins containing the RGD sequence, such as osteopontin (a major non-collagenous bone protein) and echistatin (a high affinity RGD sequence containing antagonist snake venom protein), showed different binding affinities. This demonstrates that the context of the RGD sequence within a protein has considerable influence upon the final binding force for receptor interaction. These data also demonstrate that AFM, as a methodological approach, can be adapted to cell biology studies wherever cell-matrix interactions play a critical role, and, moreover, may have applicability to the analysis of receptor-ligand interactions in cell membranes in general.  相似文献   

12.
The atomic force microscopy (AFM) has been used as a force sensor to measure unbinding forces of single bound complexes in the nanonewton and piconewton range. Force spectroscopy measurements can be applied to study both intermolecular and intramolecular interactions of complex biological and synthetic macromolecules. Although the AFM has been extensively used as a nano force sensor, the commercially available cantilever is limited to silicon and silicon nitride. Those materials reduce the adhesion sensitivity with specific surface and/or molecule. Here, we functionalized the AFM tip with carboxylic groups by applying acrylic acid (AA) vapor at radio frequency plasma treatment at 100 W for 5 min. This method provides a remarkable sensitivity enhancement on the functional group interaction specificity. The functionalized tip was characterized by scanning electron microscopy. The electron beam high resolution images have not shown significant tip sharpness modification. Silicon wafers (1 0 0)-no treated and functionalized by AA plasma treatment-were characterized by Auger electron spectroscopy to elucidate the silicon surface sputtering and demonstrate functionalization. The Fourier transform-infrared spectroscopy spectrum shows a high absorbance of avidin protein over the silicon surface functionalized by AA plasma treatment.We carried out force spectroscopy assay to measure the unbinding force between the well-established pair biotin-avidin. At pulling speed of 2 μm/s, we measured the unbinding force of 106?±?23 pN, which is in good agreement with the literature, demonstrating the effectiveness of the tip functionalization by AA plasma treatment in biological studies.  相似文献   

13.
In this study, we have developed a method of mechanical force detection for ligands bound to receptors on a cell surface, both of which are involved in a signal transduction pathway. This pathway is an autocrine pathway, involving the production of insulin‐like growth factor‐II (IGF‐II) and activation of the IGF‐I receptor, involved in myoblast differentiation induced by MyoD in C3H10T1/2 mouse mesenchymal stem cells. Differentiation of C3H10T1/2 was induced with the DNA demethylation agent 5‐azacytidine (5‐aza). The etched AFM tip used in the force detection had a flat surface of which about 10 µm2 was in contact with a cell surface. The forces required to rupture the interactions of IGF‐IIs on a cell and anti mouse IGF‐II polyclonal antibody immobilized on an etched AFM tip were measured within 5 days of induction of differentiation. The mean unbinding force for a single paired antibody–ligand on a cell was about 81 pN, which was measured at a force loading rate of about 440 nN/s. The percentage of unbinding forces over 100 pN increased to 32% after 2 days from the addition of 5‐aza to the medium. This method could be used in non‐invasive and successive evaluation of a living cell's behavior. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
Sample-probe contact duration (dwell time) and loading force are two important parameters for the atomic force microscopy (AFM) force spectroscopy measurements of ligand-receptor interaction. A prolonged contact time may be required to initiate ligand-receptor binding as a result of slow on-rate kinetics or low reactant density. In general, increasing contact duration promotes nonspecific interactions between the substrate and the functionalized cantilever and, thus, masking the detection of the specific interactions. To reduce the nonspecific interactions in AFM force measurements requiring extended substrate-probe contact, we investigated the interaction of bovine serum albumin (BSA)-functionalized cantilever with BSA-coated glass, polyethylene glycol (PEG)-functionalized glass, Pluronic-treated Petri dishes and agarose beads. The frequency of nonspecific interaction between the BSA-functionalized cantilever and the different samples increased with loading force and dwell time. This increase in nonspecific adhesion can be attributed to the interaction mediated by forced unfolding of BSA. By reducing the loading force, the contact duration of the AFM probe with an agarose bead can be extended to a few minutes without nonspecific adhesion.  相似文献   

15.
Weak non-covalent interactions between large molecules govern interfacial structure and adhesion in biology. Because of thermal activation, these bonds have modest lifetimes and bond lifetimes are progressively shortened under application of external force. Theory predicts that bond survival time depends on how fast the force is applied and the expected survival time specifies the most likely breakage force (strength) at a given loading rate (force/time). Plotted as a function of log(e) (loading rate), the dynamic spectrum of bond strength provides an image of the prominent barriers traversed in the energy landscape along the unbinding pathway, which establishes a direct link between measurements of bond force and molecular-scale chemistry. Experimentally, the challenge is to measure bond strength over several orders of magnitude in loading rate. With a recently designed probe technique, we have measured strengths of single receptor-ligand bonds and receptor-membrane anchoring over an enormous range of loading rates from 10(-1) pN/s to 10(5) pN/s, which reveals an inner view of the complexity of these interactions.  相似文献   

16.
Cell-substrate separation: effect of applied force and temperature   总被引:1,自引:0,他引:1  
We measure the change in cell-substrate separation in response to an upward force by combining two relatively new techniques, Electric Cell-substrate Impedance Sensing (ECIS) to measure average cell-substrate separation, and collagen-coated magnetic beads to apply force to the top (dorsal) surface of cells. The collagen-coated ferric oxide beads attach to integrin receptors in the dorsal surfaces of osteoblastlike ROS 17/2.8 cells. Magnetic force is controlled by the position and the number of permanent magnets, applying an average 320 or 560 pN per cell. Comparing model calculations with experimental impedance data, the junctional resistivity of the cell layer and the average distance between the lower (ventral) cell surface and substrate can be determined. The ECIS analysis shows that these forces produce an increase in the distance between the ventral cell surface and the substrate that is in the range of 10 to 25%. At temperatures of 4°, 22° and 37 °C, the measured cell surface-substrate distances without magnetic beads are 84 ± 4, 45 ± 2 and 38 ± 2 nm. The force-induced changes at 22° are 11 ± 3 and 21 ± 3 nm for 320 and 560 pN, and at 37° they are 5 ± 2 and 9 ± 2 nm. The resulting cell-substrate spring constants at 22° and 37° are thus about 28 and 63 pN nm–1 (dyne cm–1). Using a reasonable range for the number for individual integrin-ligand adhesion bonds gives a range for the spring constant of the individual adhesion bond of from about 10–3 to 10–1 pN nm–1. These data also provide evidence that the number of adhesion bonds per cell increases with temperature. Received: 20 June 1997 / Accepted: 24 August 1997  相似文献   

17.
The binding force between a liposome and the C2A domain of synaptotagmin I was determined by an atomic force microscopy (AFM). Liposomes were immobilized on the surface of the L1 sensor chip and the C2A domains, which recognize phosphatidylserine, were chemically conjugated onto a gold-coated cantilever tip. The average interaction force between the C2A domain and the liposome was 306 (±57) pN while the force between untreated cantilever and the liposome was 58 (±16) pN. This work helps understand the physicochemical interactions between proteins and lipid vesicles for the design of high affinity protein probes against the apoptotic cell surface. Revisions requested 13 December 2005; Revisions received 9 January 2006  相似文献   

18.
The properties of substrates and extracellular matrices (ECM) are important factors governing the functions and fates of mammalian adherent cells. For example, substrate stiffness often affects cell differentiation. At focal adhesions, clustered–integrin bindings link cells mechanically to the ECM. In order to quantitate the affinity between cell and substrate, the cell adhesion force must be measured for single cells. In this study, forcible detachment of a single cell in the vertical direction using AFM was carried out, allowing breakage of the integrin–substrate bindings. An AFM tip was fabricated into an arrowhead shape to detach the cell from the substrate. Peak force observed in the recorded force curve during probe retraction was defined as the adhesion force, and was analyzed for various types of cells. Some of the cell types adhered so strongly that they could not be picked up because of plasma membrane breakage by the arrowhead probe. To address this problem, a technique to reinforce the cellular membrane with layer-by-layer nanofilms composed of fibronectin and gelatin helped to improve insertion efficiency and to prevent cell membrane rupture during the detachment process, allowing successful detachment of the cells. This method for detaching cells, involving cellular membrane reinforcement, may be beneficial for evaluating true cell adhesion forces in various cell types.  相似文献   

19.
Epidermal growth factor receptor (EGFR) is often constitutively stimulated in many cancers owing to the binding of ligands such as epidermal growth factor (EGF). Therefore, it is necessary to investigate the interaction between EGFR and its targeting biomolecules. The main aim of this study was to estimate the binding affinity and adhesion force of two targeting molecules, anti-EGFR monoclonal antibody (mAb LA1) and the peptide GE11 (YHWYGYTPQNVI), with respect to EGFR and to compare these values with those obtained for the ligand, EGF. Surface plasmon resonance (SPR) was used to determine the equilibrium dissociation constant (KD) for evaluating the binding affinity. Atomic force microscopy (AFM) was performed to estimate the adhesion force. In the case of EGFR, the KD of EGF, GE11, and mAb LA1 were 1.77 × 10−7, 4.59 × 10−4 and 2.07 × 10−9, respectively, indicating that the binding affinity of mAb LA1 to EGFR was higher than that of EGF, while the binding affinity of GE11 to EGFR was the lowest among the three molecules. The adhesion force between EGFR and mAb LA1 was 210.99 pN, which is higher than that observed for EGF (209.41 pN), while the adhesion force between GE11 and EGFR was the lowest (59.51 pN). These results suggest that mAb LA1 binds to EGFR with higher binding affinity than EGF and GE11. Moreover, the adhesion force between mAb LA1 and EGFR was greater than that observed for EGF and GE11. The SPR and AFM experiments confirmed the interaction between the receptor and targeting molecules. The results of this study might aid the screening of ligands for receptor targeting and drug delivery.  相似文献   

20.
Glycophorin A (GpA) is one of the most abundant transmembrane proteins in human erythrocytes and its interaction with lectins has been studied as model systems for erythrocyte related biological processes. We performed a force measurement study using the force mode of atomic force microscopy (AFM) to investigate the single molecular level biophysical mechanisms involved in GpA-lectin interactions. GpA was mounted on a mica surface or natively presented on the erythrocyte membrane and probed with an AFM tip coated with the monomeric but multivalent Psathyrella velutina lectin (PVL) through covalent crosslinkers. A dynamic force spectroscopy study revealed similar interaction properties in both cases, with the unbinding force centering around 60 pN with a weak loading rate dependence. Hence we identified the presence of one energy barrier in the unbinding process. Force profile analysis showed that more than 70% of GpAs are free of cytoskeletal associations in agreement with previous reports.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号