首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
2.
BACKGROUND: Molecular diagnostic methods can complement existing tools to improve the diagnosis of malaria. However, they require good laboratory infrastructure thereby restricting their use to reference laboratories and research studies. Therefore, adopting molecular tools for routine use in malaria endemic countries will require simpler molecular platforms. The recently developed loop-mediated isothermal amplification (LAMP) method is relatively simple and can be improved for better use in endemic countries. In this study, we attempted to improve this method for malaria diagnosis by using a simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in one platform. We refer to this as the RealAmp method. METHODOLOGY AND SIGNIFICANT FINDINGS: Published genus-specific primers were used to test the utility of this method. DNA derived from different species of malaria parasites was used for the initial characterization. Clinical samples of P. falciparum were used to determine the sensitivity and specificity of this system compared to microscopy and a nested PCR method. Additionally, directly boiled parasite preparations were compared with a conventional DNA isolation method. The RealAmp method was found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was generally less than 60 minutes. All human-infecting Plasmodium species were detected. The sensitivity and specificity of RealAmp in detecting P. falciparum was 96.7% and 91.7% respectively, compared to microscopy and 98.9% and 100% respectively, compared to a standard nested PCR method. In addition, this method consistently detected P. falciparum from directly boiled blood samples. CONCLUSION: This RealAmp method has great potential as a field usable molecular tool for diagnosis of malaria. This tool can provide an alternative to conventional PCR based diagnostic methods for field use in clinical and operational programs.  相似文献   

3.
Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.  相似文献   

4.
Sistan and Baluchestan province, South-East of Iran, has been reported as an endemic area of malaria [Sadrizadeh B. Malaria in the world, in the eastern Mediterranean region and in Iran: Review article. WHO/EMRO Report 2001: 1-13.]. The main objective of this research was to perform rapid and correct diagnoses of malaria infection. Blood specimens were collected from 140 suspected volunteers. The Giemsa-stained slides examination and nested PCR for amplification of the Plasmodium small subunit ribosomal genes (ssrRNA) were utilized. The results demonstrated 118 out of 140 cases (84.3%) positive for malaria parasites, including 60.7%, 20.7% and 2.9% as having Plasmodium vivax (P.v), Plasmodium falciparum (P.f) and mixed infections (P.v+P.f), respectively by microscopy. The nested PCR detected malaria parasites in 134 samples (94.3%), consisting of 51.4% P.v, 12.6% P.f and 29.3% mixed infections. The PCR analysis detected 37 cases of mixed infections more than that of the routine microscopy. These results suggested that there are a considerable number of cases with mixed infections in the study area that mainly remain undiagnosed by microscopy. It is also concluded that the nested PCR is a suitable complement to microscopy for accurate specific diagnosis of malaria species in field.  相似文献   

5.
Two duplex real-time PCR assays were developed to diagnose three human parasites: Plasmodium falciparum, Plasmodium vivax and Plasmodium malariae. TaqMan duplex real-time PCR was evaluated in 263 blood samples of suspected malaria patients by comparing results against those obtained with microscopy and nested PCR. Compared with nested PCR, duplex real-time PCR assays showed 100% sensitivity and specificity. Duplex real-time PCR detected all mixtures of P. falciparum and P. vivax DNA, except at threshold detection limits for both parasites in which P. vivax was not amplified. Threshold detection limits of real-time PCR were 3.1, 0.3 and 0.8 parasites per microlitre of blood for P. falciparum, P. vivax and P. malariae, respectively. Duplex real-time PCR allows the detection of malarial cases, including mixed species infection, it simplifies analysis and reduces cost. Thus, this protocol may prove invaluable for use in the diagnosis of human infection, trial treatments and epidemiologic studies in which high-throughput analyses are often required.  相似文献   

6.

Background

Rapid diagnosis and correct treatment of cases are the main objectives of control programs in malaria-endemic areas.

Methods and results

To evaluate these criteria and in a comparative study, blood specimens were collected from 120 volunteers seeking care at the Malaria Health Center in Chahbahar district. One hundred and seven out of 120 Giemsa-stained slides were positive for malaria parasites by microscopy. Eighty-four (70%) and 20 (16.7%) were identified as having only Plasmodium vivax and Plasmodium falciparum infections, respectively, while only 3 (2.5%) were interpreted as having mixed P. vivax-P. falciparum infections. The target DNA sequence of the 18S small sub-unit ribosomal RNA (ssrRNA) gene was amplified by Polymerase Chain Reaction (PCR) and used for the diagnosis of malaria in south-eastern Iran. One hundred twenty blood samples were submitted and the results were compared to those of routine microscopy. The sensitivity of PCR for detection of P. vivax and P. falciparum malaria was higher than that of microscopy: nested PCR detected 31 more mixed infections than microscopy and parasite positive reactions in 9 out of the 13 microscopically negative samples. The results also confirmed the presence of P. vivax and P. falciparum.

Conclusions

These results suggest that, in places where transmission of both P. vivax and P. falciparum occurs, nested PCR detection of malaria parasites can be a very useful complement to microscopical diagnosis.  相似文献   

7.

Background

Sensitive and specific detection of malarial parasites is crucial in controlling the significant malaria burden in the developing world. Also important is being able to identify life threatening Plasmodium falciparum malaria quickly and accurately to reduce malaria related mortality. Existing methods such as microscopy and rapid diagnostic tests (RDTs) have major shortcomings. Here, we describe a new real-time PCR-based diagnostic test device at point-of-care service for resource-limited settings.

Methods

Truenat® Malaria, a chip-based microPCR test, was developed by bigtec Labs, Bangalore, India, for differential identification of Plasmodium falciparum and Plasmodium vivax parasites. The Truenat Malaria tests runs on bigtec’s Truelab Uno® microPCR device, a handheld, battery operated, and easy-to-use real-time microPCR device. The performance of Truenat® Malaria was evaluated versus the WHO nested PCR protocol. The Truenat® Malaria was further evaluated in a triple-blinded study design using a sample panel of 281 specimens created from the clinical samples characterized by expert microscopy and a rapid diagnostic test kit by the National Institute of Malaria Research (NIMR). A comparative evaluation was done on the Truelab Uno® and a commercial real-time PCR system.

Results

The limit of detection of the Truenat Malaria assay was found to be <5 parasites/μl for both P. falciparum and P. vivax. The Truenat® Malaria test was found to have sensitivity and specificity of 100% each, compared to the WHO nested PCR protocol based on the evaluation of 100 samples. The sensitivity using expert microscopy as the reference standard was determined to be around 99.3% (95% CI: 95.5–99.9) at the species level. Mixed infections were identified more accurately by Truenat Malaria (32 samples identified as mixed) versus expert microscopy and RDTs which detected 4 and 5 mixed samples, respectively.

Conclusion

The Truenat® Malaria microPCR test is a valuable diagnostic tool and implementation should be considered not only for malaria diagnosis but also for active surveillance and epidemiological intervention.  相似文献   

8.
The Quantitative Buffy Coat (QBC) system was used for the detection and identification of malaria parasites in blood specimens from 570 residents of Oksibil, an isolated highland valley in the eastern Jayawijaya Mountains of Irian Jaya (Indonesian New Guinea). The availability of a battery-powered centrifuge and a fiberoptic Paralens enabled us to complete and interpret the assay in this remote environment. Of 322 QBC tubes examined for 2-4 min each, results of 295 (92%) concurred with findings on the matched Giemsa-stained thick smear (GTS). The 27 discrepant results included 13 QBC+/GTS- that, upon reexamination, were found to be GTS+. When using the corrected GTS results as the standard, the sensitivity and specificity of the QBC were 94% and 96%, respectively. Because electricity was available only 3 hr per day, it was decided to decrease the examination for an additional 248 QBC to a maximum of 90 sec per tube. This shortened inspection time resulted in a reduction of sensitivity to 53% but specificity was preserved at 89%. Forty-two of 45 conflicting results, QBC-/GTS+ from cases of light Plasmodium falciparum infections with < 1 trophozoite or gametocyte per field, were resolved by reexamination of the QBC in the laboratory. Tubes held at 4 C could be reexamined, without noticeable loss of fluorescence, for at least 6 wk after collection. Despite some difficulty in the identification of Plasmodium species, it was concluded that the QBC is an easy, sensitive method for the rapid diagnosis of malaria in the field and that it provides the inexperienced microscopist with an additional means for on-site identification of individuals needing treatment.  相似文献   

9.
ABSTRACT: BACKGROUND: Malaria is a leading public health problem in Ethiopia. Accurate diagnosis of Plasmodium infections is crucial for the reduction of malaria in tropical areas and for epidemiological studies. The role of light microscopy (LM) as gold standard has been questioned and, therefore, new molecular methods have been developed for the detection of Plasmodium species. The aim of the present work was to compare different malaria diagnostic methods in order to detect the most common species of Plasmodium and to broaden the knowledge of malaria prevalence in a hospital in a rural area in Ethiopia. METHODS: A cross-sectional survey of 471 individuals was carried out in a hospital in the rural area of Gambo (Ethiopia). Blood samples were prepared for microscopic observation and collected in filter paper for Seminested-Multiplex PCR (SnM-PCR) and real time PCR (qPCR) testing. The SnM-PCR was considered as the gold standard technique and compared with the rest. Thus, agreement between SnM-PCR and LM was determined by calculating Kappa Statistics and correlation between LM and qPCR quantification was calculated by pair-wise correlation co-efficient. RESULTS: Samples analysed by LM and SnM-PCR were positive for Plasmodium sp. 5.5% and 10.5%, respectively. Sensitivity was 52.2% by LM and 70% by qPCR. Correlation co-efficient between microscopy counts and qPCR densities for Plasmodium vivax was R2 = 0.586. Prevalence was estimated at 7% (95% CI: 4.7-9.3). Plasmodium vivax was the dominant species detected and the difference was statistically significant (chi2 = 5.121 p < 0.05). The highest prevalence of the parasite (10.9%) was observed in age groups under 15 years old. CONCLUSION: Accurate malaria diagnostic methods have a great effect in the reduction of the number of malaria-infected individuals. SnM-PCR detection of malaria parasites may be a very useful complement to microscopic examination in order to obtain the real prevalence of each Plasmodium species. Although SnM-PCR shows that it is a good tool for the determination of Plasmodium species, today light microscopy remains the only viabletool for malaria diagnosis in developing countries. Therefore, re-inforcement in the training of microscopists is essential for making the correct diagnosis of malaria. Plasmodium vivax was the predominant species in Gambo, a meso-endemic area for this species.  相似文献   

10.
Blood samples from 182 patients presenting at the out-patient clinic in Richard-Toll. Senegal were analysed by Thick smear microscopy, the QBC, PCR and the new dipstick PATH Malaria assay which detects the histidine rich protein II antigen of Plasmodium falciparum. Thick smear microscopy was used as the reference method. Sensitivity, specificity, predictive positive and negative values were 100%, 83.6%, 93.4% and 100% QBC respectively; 100%, 72.7%, 89.4% and 100% for PCR; 96%, 92.7%, 96.8% and 91% for the PATH assay. PATH assay failed to detect one positive sample with Plasmodium malariae. Assays were also compared with regard to the expense of equipment and reagents and speed and ease of use. The rapid PATH assay can be performed with minimal training and may be specially useful in areas where P. falciparum is the predominant malaria species, in epidemic malaria regions, and where skilled microscopy is not readily available.  相似文献   

11.
Several polymerase chain reaction (PCR)-based methods have recently been developed for diagnosing malarial infections in both birds and reptiles, but a critical evaluation of their sensitivity in experimentally-infected hosts has not been done. This study compares the sensitivity of several PCR-based methods for diagnosing avian malaria (Plasmodium relictum) in captive Hawaiian honeycreepers using microscopy and a recently developed immunoblotting technique. Sequential blood samples were collected over periods of up to 4.4 yr after experimental infection and rechallenge to determine both the duration and detectability of chronic infections. Two new nested PCR approaches for detecting circulating parasites based on P. relictum 18S rRNA genes and the thrombospondin-related anonymous protein (TRAP) gene are described. The blood smear and the PCR tests were less sensitive than serological methods for detecting chronic malarial infections. Individually, none of the diagnostic methods was 100% accurate in detecting subpatent infections, although serological methods were significantly more sensitive (97%) than either nested PCR (61-84%) or microscopy (27%). Circulating parasites in chronically infected birds either disappear completely from circulation or to drop to intensities below detectability by nested PCR. Thus, the use of PCR as a sole means of detection of circulating parasites may significantly underestimate true prevalence.  相似文献   

12.
ABSTRACT: BACKGROUND: Molecular tools are very sensitive and specific and could be an alternative for the diagnosis of malaria. The complexity and need for expensive equipment may hamper implementation and, therefore, simplifications to current protocols are warranted. METHODS: A PCR detecting the different Plasmodium species and differentiating between Plasmodium falciparum and Plasmodium vivax was developed and combined with a nucleic acid lateral flow immuno-assay (PCR-NALFIA) for amplicon detection. The assay was thoroughly evaluated for the analytical sensitivity and specificity in the laboratory, the robustness and reproducibility in a ring trial and accuracy and predictive value in a field trial. RESULTS: The analytical sensitivity and specificity were 0.978 (95% CI: 0.932-0.994) and 0.980 (95% CI: 0.924-0.997), respectively, and were slightly less sensitive for the detection of P. vivax than for P. falciparum. The reproducibility tested in three laboratories was very good (k = 0.83). This evaluation showed that the PCR machine used could influence the results. Accuracy was evaluated in Thailand and compared to expert microscopy and rapid diagnostic tests (RDTs). The overall and P. falciparum-specific sensitivity and specificity was good ranging from 0.86-1 and 0.95-0.98 respectively, compared to microscopy. Plasmodium vivax detection was better than the sensitivity of RDT, but slightly less than microscopy performed in this study. CONCLUSION: PCR-NALFIA is a sensitive, specific and robust assay able to identify Plasmodium species with good accuracy. Extensive testing including a ring trial can identify possible bottlenecks before implementation and is therefore essential to perform in additon to other evaluations.  相似文献   

13.
Malaria is caused by five species of Plasmodium in humans. Microscopy is currently used for pathogen detection, requiring considerable training and technical expertise as the parasites are often difficult to differentiate morphologically. Rapid diagnostic tests are as reliable as microscopy and offer faster diagnoses but possess lower detection limits and are incapable of distinguishing among the parasitic species. To improve global health efforts towards malaria control, a rapid, sensitive, species-specific, and economically viable diagnostic method is needed. In this study, we designed a malaria diagnostic method involving a multiplex single-tube nested PCR targeting Plasmodium mitochondrial cytochrome c oxidase III and single-stranded tag hybridization chromatographic printed-array strip. The detection sensitivity was found to be at least 40 times higher than that of agarose gel electrophoresis with ethidium bromide. This system also enables the identification of both single- and mixed-species malaria infections. The assay was validated with 152 Kenyan samples; using nested PCR as the standard, the assay's sensitivity and specificity were 88.7% and 100.0%, respectively. The turnaround time required, from PCR preparation to signal detection, is 90 min. Our method should improve the diagnostic speed, treatment efficacy, and control of malaria, in addition to facilitating surveillance within global malaria eradication programs.  相似文献   

14.
The species-specific nested-PCR previously described by Snounou and others for detecting the four parasite species that cause human malaria is evaluated in the current study testing 230 blood samples. The results are compared with those obtained by microscopy and, for 101 samples out of 230, with those previously obtained by a genus-specific PCR based method (pg-PCR) followed by species-specific Southern-blot hybridization. All blood specimens were obtained from patients (127 foreigners and 103 Italians) with a suspect clinical diagnosis of imported malaria in Italy: 76 were positive by microscopy and 83 were positive by nested-PCR. The last method also revealed 10 double infections (8 foreigners and 2 Italians) which were not identified by microscopy or by pg-PCR with species-specific Southern-blot hybridization. Fifty-four out of 83 positive samples tested by nested-PCR were submitted to genomic sequence analysis, which confirmed the presence of DNA region portion encoding the 18S rRNA corresponding to the Plasmodium species identified by nested-PCR. These results demonstrate that the nested-PCR assay surpasses microscopy and pg-PCR with species-specific Southern-blot hybridization, both in sensitivity and in diagnostic accuracy. Moreover, it is quicker because it requires no further blotting or hybridization of PCR amplification products. This method also offers a clear advantage in the detection of mixed infections, which is important not only for successful medical treatment but also for the study of malaria epidemiology. Finally, our study also highlights the value of genomic sequence analysis for validating PCR results.  相似文献   

15.
Plasmodium vivax infections remain a major source of malaria-related morbidity and mortality. Early and accurate diagnosis is an integral component of effective malaria control programs. Conventional molecular diagnostic methods provide accurate results but are often resource-intensive, expensive, have a long turnaround time and are beyond the capacity of most malaria-endemic countries. Our laboratory has recently developed a new platform called RealAmp, which combines loop-mediated isothermal amplification (LAMP) with a portable tube scanner real-time isothermal instrument for the rapid detection of malaria parasites. Here we describe new primers for the detection of P. vivax using the RealAmp method. Three pairs of amplification primers required for this method were derived from a conserved DNA sequence unique to the P. vivax genome. The amplification was carried out at 64°C using SYBR Green or SYTO-9 intercalating dyes for 90 minutes with the tube scanner set to collect fluorescence signals at 1-minute intervals. Clinical samples of P. vivax and other human-infecting malaria parasite species were used to determine the sensitivity and specificity of the primers by comparing with an 18S ribosomal RNA-based nested PCR as the gold standard. The new set of primers consistently detected laboratory-maintained isolates of P. vivax from different parts of the world. The primers detected P. vivax in the clinical samples with 94.59% sensitivity (95% CI: 87.48–98.26%) and 100% specificity (95% CI: 90.40–100%) compared to the gold standard nested-PCR method. The new primers also proved to be more sensitive than the published species-specific primers specifically developed for the LAMP method in detecting P. vivax.  相似文献   

16.
A PCR method involving a genus-specific oligonucleotides set and Southern blot hybridization with four species-specific probes to P. falciparum, P. vivax, P. malariae and P. ovale was evaluated for the detection of malaria parasites in blood samples from 101 patients with clinically suspect malaria infection imported to Italy. Plasmodium falciparum was the main species detected. As determined by microscopy, 53 (52.4%) patients had malaria and of these: 40 (75.5%) were infected with P. falciparum; 7 (13.2%) with P. vivax; 1 (1.9%) with P. ovale; 3 (5.7%) with P. malariae; 1 (1.9%) with P. vivax or P. ovale; and 1 (1.9%) with P. falciparum or P. vivax. Ninety-seven out 101 blood samples were submitted to ParaSight-F test which showed a sensitivity of 94.73%, and a specificity of 93.22%, as compared to microscopy. The PCR assay using the genus-specific oligonucleotide primer set (pg-PCR) was able to detect 53 (52.4%) infections and showed a sensitivity of 100% and a specificity of 100%, when compared to microscopy. The parasite species were identified by Southern blot hybridization using species-specific probes and 40 (75.5%) samples were P. falciparum positive, 5 (9.4%) P. vivax positive, 4 (7.5%) P. ovale positive, and 2 (3.8%) P. malariae positive. When the Southern blot results were compared to those of blood-film diagnosis, we observed some disagreement. In particular, compared to Southern blot, microscopy underestimated P. ovale infection; blood film analysis recognised only 1 P. ovale sample, whereas Southern blot recognised 4 P. ovale positive samples (by microscopy, 2 of these were detected as P. vivax, 1 as P. ovale or P. vivax, and the other as P. falciparum or P. vivax). Southern blot hybridization was unable to identify one P. falciparum and one P. vivax positive case detected by microscopy. We also plan to use a reference nested-PCR assay to clarify the disagreement observed between microscopy and Southern blot hybridization.  相似文献   

17.
BACKGROUND: Serological tests to detect antibodies specific to Plasmodium vivax could be a valuable tool for epidemiological studies, for screening blood donors in areas where the malaria is not endemic and for diagnosis of infected individuals. Because P. vivax cannot be easily obtained in vitro, ELISA assays using total or semi-purified antigens are rarely used. Based on this limitation, we tested whether recombinant proteins representing the 19 kDa C-terminal region of the merozoite surface protein-1 of P. vivax (MSP119) could be useful for serological detection of malaria infection. METHODS: Three purified recombinant proteins produced in Escherichia coli (GST-MSP119, His6-MSP119 and His6-MSP119-PADRE) and one in Pichia pastoris (yMSP119-PADRE) were compared for their ability to bind to IgG antibodies of individuals with patent P. vivax infection. The method was tested with 200 serum samples collected from individuals living in the north of Brazil in areas endemic for malaria, 53 serum samples from individuals exposed to Plasmodium falciparum infection and 177 serum samples from individuals never exposed to malaria. RESULTS: Overall, the sensitivity of the ELISA assessed with sera from naturally infected individuals was 95%. The proportion of serum samples that reacted with recombinant proteins GST-MSP119, His6-MSP119, His6-MSP119-PADRE and yMSP119-PADRE was 90%, 93.5%, 93.5% and 93.5%, respectively. The specificity values of the ELISA determined with sera from healthy individuals and from individuals with other infectious diseases were 98.3% (GST-MSP119), 97.7% (His6-MSP119 and His6-MSP119-PADRE) or 100% (yMSP119-PADRE). CONCLUSIONS: Our study demonstrated that for the Brazilian population, an ELISA using a recombinant protein of the MSP119 can be used as the basis for the development of a valuable serological assay for the detection of P. vivax malaria.  相似文献   

18.
19.
Tuberculosis is an under-recognized yet catastrophic health problem, particularly in developing countries. The HIV pandemic has served to increase the number of susceptible individuals, and multidrug-resistance and poor socioeconomic conditions also augment the prevalence and the consequences of the disease. To control the disease and its spread, it is vital that tuberculosis diagnostics are accurate and rapid. Whereas microscopy and culture have several limitations (low sensitivity is a problem for the former, while the latter has a delayed turnaround time), PCR-based techniques targeting regions of the Mycobacterium tuberculosis genome such as IS6110 have proved to be useful. The purpose of this review is to assess the use of PCR-RFLP, nested PCR and real-time PCR protocols and the choice of target regions for the detection of M. tuberculosis. Real-time PCR for the detection of M. tuberculosis target genes in clinical specimens has contributed to improving diagnosis and epidemiologic surveillance in the past decade. However, targeting one genome sequence such as IS6110 may not by itself be sufficiently sensitive to reach 100% diagnosis, especially in the case of pulmonary tuberculosis. Additional testing for target genome sequences such as hsp65 seems encouraging. An interesting approach would be a multiplex real-time PCR targeting both IS6110 and hsp65 to achieve comprehensive and specific molecular diagnosis. This technology needs development and adequate field testing before it becomes the acceptable gold standard for diagnosis.  相似文献   

20.

Background

Most commonly used malaria diagnostic tests, including microscopy and antigen-detecting rapid tests, cannot reliably detect low-density infections which are frequent in low transmission settings. Molecular methods such as polymerase chain reaction (PCR) are highly sensitive but remain too laborious for field deployment. In this study, the applicability of a malaria diagnosis kit based on loop-mediated isothermal amplification (mLAMP) was assessed in malaria endemic areas of Colombia with Plasmodium vivax predominance.

Methodology/Principal Findings

First, a passive case detection (PCD) study on 278 febrile patients recruited in Tierralta (department of Cordoba) was conducted to assess the diagnostic performance of the mLAMP method. Second, an active case detection (ACD) study on 980 volunteers was conducted in 10 sentinel sites with different epidemiological profiles. Whole blood samples were processed for microscopic and mLAMP diagnosis. Additionally RT-PCR and nested RT-PCR were used as reference tests. In the PCD study, P. falciparum accounted for 23.9% and P. vivax for 76.1% of the infections and no cases of mixed-infections were identified. Microscopy sensitivity for P. falciparum and P. vivax were 100% and 86.1%, respectively. mLAMP sensitivity for P. falciparum and P. vivax was 100% and 91.4%, respectively. In the ACD study, mLAMP detected 65 times more cases than microscopy. A high proportion (98.0%) of the infections detected by mLAMP was from volunteers without symptoms.

Conclusions/Significance

mLAMP sensitivity and specificity were comparable to RT-PCR. LAMP was significantly superior to microscopy and in P. vivax low-endemicity settings and under minimum infrastructure conditions, it displayed sensitivity and specificity similar to that of single-well RT-PCR for detection of both P. falciparum and P. vivax infections. Here, the dramatically increased detection of asymptomatic malaria infections by mLAMP demonstrates the usefulness of this new tool for diagnosis, surveillance, and screening in elimination strategies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号