首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
During the last 15 years several studies have investigated a possible relationship between exposure to electromagnetic fields (EMF) and childhood cancer. There is considerable variation between these studies with respect to methods of exposure assessment and reported results. Methods of exposure assessment range from simple visual criteria to costly and time consuming measurements or estimations of electric flux density. Additional individual refinements further hinder the comparability of results. We carried out several meta-analyses of data published so far taking into account the heterogeneity between studies as far as possible. Our particular interest was to investigate a potential dose-response-like relationship by comparing analyses for different cut-off points of exposure. Our meta-analyses suggest a marginal association between all cancer diagnoses combined and EMF exposure assessed by the two-level wire code (odds ratio, OR= 1.37, 95% confidence interval, CI: 0.94–2.00). Based on this criterion a significant effect was found for cases of leukemia (OR= 1.66, CI: 1.11–2.49) but not for central nervous system (CNS) tumors (OR= 1.5, CI: 0.69–3.26) or lymphomas (OR= 1.32, CI: 0.52–3.37). A significant increase in overall cancer risk with increasing stages of the four-level wire code (P=0.003) could not be confirmed when data of the initial study performed by Wertheimer and Leeper were excluded (P=0.17). When the exposure criterion was based on distance to the transmission line, estimated ORs for all cancers combined and for leukemias increased with distances decreasing from 100 to 25 m. Those analyses incorporating data on measured or calculated EMFs demonstrated also an increase of overall cancer risk with higher cut-off points. However, regarding individual diagnoses, this finding was reflected only in the group of brain tumors. One possible explanation for the high degree of heterogeneity between studies - especially with respect to methods of exposure assessment and choice of the respective cutpoint relevant for an increase in cancer risk - could be that published cut-off points were not always chosen in advance, but were selected because in exploratory analyses the most striking results were obtained with these specific cut-off values. Should this speculation be true at least partially, any meta-analysis will yield a false-positive finding. Further results of comparable studies with strictly a priori planned analyses are necessary to properly investigate a possible link between EMF and childhood cancer.  相似文献   

2.
Residential magnetic and electric fields   总被引:1,自引:0,他引:1  
A magnetic flux density (MFD) and electric-field (E-field) data-acquisition system was built for characterizing extremely low-frequency fields in residences. Every 2 min during 24-h periods, MFD and E-field measurements were made in 43 homes in King, Pierce, and Snohomish counties of Washington State. The total electrical energy used in each residence during the 24-h measurement period was also recorded, and maps were drawn to scale of the distribution wiring within 43 m (140 ft) of these homes. Finally, on a separate date, field measurements were made in each home during an epidemiological interview. The results of this study can be summarized as follows: 1) 24-h-average MFD measured at two separate points in the family room were correlated, as were a 24-h-average bedroom measurement and the mean of the two family-room measurements. 2) The 24-h-average family-room MFD and E-field measurements were uncorrelated. 3) The 24-h-average total harmonic distortions of family-room MFD and E-fields were less than about 24% and 7%, respectively. 4) Residential MFD exhibited a definite 24-h (diurnal) cycle. 5) The 24-h-average and interviewer-measured MFD were correlated. 6) Residential 24-h-average MFD were correlated with the wiring code developed by Wertheimer and Leeper. 7) An improved prediction of 24-h-average residential MFD was obtained using the total number of service drops, the distance to neighboring transmission lines, and the number of primary phase conductors.  相似文献   

3.
The aim of this work was to study the exposure to magnetic fields of children living at different distances from a power line and to evaluate how well theoretical calculations compared with actual exposure. Personal exposure instruments were carried for 24 h by 65 schoolchildren living 28–325 m from a 300 kV transmission line; the current load was 200–700 A. About half of the children attended a school far from the power line, whereas the other half attended a school located about 25 m from the line. Exposure to magnetic fields was analyzed for three categories of location: at home, at school, and at all other places. Time spent in bed was analyzed separately. The results indicated that children who lived close to a power line had a higher magnetic field exposure than other children. The power line was the most important source of exposure when the magnetic field due to the line was greater than about 0.2 μT. Exposure at school influenced the 24 h time-weighted average results considerably in those cases where the distance between home and power line was very different from the distance between school and power line. The calculated magnetic field, based on line configuration, current load, and distance between home and power line, corresponded reasonably well with the measured field. However, the correlation depends on whether home only or 24 h exposure is used in the analysis and on which school the children attended. The calculated magnetic field seems to be a reasonably good predictor of actual exposure and could be used in epidemiological studies, at least in Norway, where the electrical system normally results in less ground current than in most other countries. Bioelectromagnetics 18:47–57, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

4.
The genotoxicity of low-level exposure to ethylene dichloride (EDC) and vinyl chloride monomer (VCM) in humans is not clear. We used lymphocyte sister chromatid exchange (SCE) frequency as a parameter to investigate the genotoxicity of low level EDC and VCM in VCM-manufacturing workers. The SCE frequency was determined for 51 male workers with exposure to VCM and/or EDC and for 20 male workers devoid of such exposure. Epidemiological data were obtained by questionnaire, and included history of smoking, drinking, and any medication taken, as well as a detailed occupational history. Personal- and area-sampling and analysis were conducted in order to calculate the time-weighted average (TWA) contaminant-exposure level corresponding to different job categories. Moderate EDC exposure around 1 ppm corresponded to a significantly greater SCE frequency than was the case for the low EDC exposure group (p<0.01). However, VCM exposure of similar level was not associated with increased SCE. We conclude that EDC may cause genotoxicity at a relatively low level of exposure.  相似文献   

5.
Childhood cancer has been modestly associated with wire codes, an exposure surrogate for power frequency magnetic fields, but less consistently with measured fields. We analyzed data on the population distribution of wire codes and their relationship with several measured magnetic field metrics. In a given geographic area, there is a marked trend for decreased prevalence from low to high wire code categories, but there are differences between areas. For average measured fields, there is a positive relationship between the mean of the distributions and wire codes but a large overlap among the categories. Better discrimination is obtained for the extremes of the measurement values when comparing the highest and the lowest wire code categories. Instability of measurements, intermittent fields, or other exposure conditions do not appear to provide a viable explanation for the difference between wire codes and magnetic fields with respect to the strength and consistency of their respective association with childhood cancer. Bioelectromagnetics 18:99–110, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

6.
To analyse working conditions and to provide information about the degree to which shoe workers are exposed to n-hexane, the urinary excretion of total 2,5-hexanedione (2,5-HD) was determined in 81 employees in 12 shoe factories. Twenty-five individuals who had experienced no exposure to solvents were used as controls. 2,5-HD was measured in spot urine samples collected from workers at the end of shift. In the urine of shoe workers, the 2,5-HD presented a mean value of 2.33 mg g-1 creatinine, a median of 1.96 mg g-1 creatinine. The mean 2,5-HD concentration in the urine samples from non-exposed subjects was 0.28 mg g-1 creatinine, the median value was 0.18 mg g-1 creatinine. The mean time-weighted average (TWA) concentration of n-hexane in 12 shoe workshops was 126.1 ppm, ranging from 23 to 215 ppm. We found a significant, but low, correlation (r = 0.40; p < 0.001) between TWA intensity of environmental exposure to n-hexane and the concentration of 2,5-HD in urine. The probable effect of toluene on the concentration of 2,5-HD was also discussed in the present study.  相似文献   

7.
With a standardized protocol under simulated gastrointestinal conditions,65Zn and59Fe dialyzability was measured for 38 diets from 7 different published studies on human absorption. The compositions of these diets were available in the form of the amounts of food ingredients used for breakfast, lunch, and dinner. Considering each of these types as a separate meal, percent dialyzability was measured. The weighted average of breakfast, lunch, dinner, and snacks, if any, was taken to represent the entire day’s bioavailability. The correlation between in vitro percent dialyzability and reported human absorption was 0.92 for zinc and 0.96 for iron and both were statistically significant (p = 0.0001). The prediction equations for zinc and iron were obtained asy = -0.7718 + 1.1038x andy = 0.3197 + 0.9084x, respectively. This indicated that in vitro dialyzability using the meal approach can be used as an index with good discriminating power for different levels of human absorption.  相似文献   

8.
Flux density and spectral measurements were carried out on magnetic fields generated by several types of motor-driven personal appliances used near the body. Among the units tested were several for which the average flux densities, as determined at the surfaces of the appliance, exceeded 0.4 mT. Time-rates-of-change (dB/dt) for several units exceeded 1000 T/s, and several units exhibited high-frequency components in the low-MHz range. Use of such appliances, although normally of short duration, can represent exposure to magnetic fields of relatively high flux density, which may also have high-frequency components. Compared to other household and commercial sources of magnetic fields, those generated by certain motor-driven personal appliances may represent a significant contribution to time-weighted average exposure and may represent an important source of local induced currents in the body. Furthermore, high-frequency transients that represent only a minor contribution to time-weighted average exposure may generate significant instantaneous induced currents. © 1994 Wiley-Liss, Inc.
  • 1 This article is a US Government work and, as such, is in the public domain in the United States of America.
  •   相似文献   

    9.
    In the course of a study on residential magnetic-field exposure, some incidental data were obtained that bear on the issue of confounding of magnetic field exposure by social class. We have explored the possibility that the magnetic flux density of 50 Hz fields measured in Melbourne streets is correlated with a number of variables that index the socio-economic status of the neighborhood. We have examined also for a correlation between field-intensity levels and sums of some or all of the indicators, which were weighted to provide an overall score on socio-economic status. Although some of the indexes were weakly, but significantly, correlated with environmental levels of magnetic fields, the combined indices were not. These results indicate that socio-economic status is not likely to be a confounder in epidemiological studies of residential exposure to ELF magnetic fields in Melbourne.  相似文献   

    10.
    Human health risks associated with changes in synthetic chemical pesticide use following the introduction of genetically modified crops are quantified in this article. Bacillus thuringiensis ( Bt ) cotton and herbicide-tolerant (HT) soybean, two genetically modified crops, were chosen as the focus for this study based on their global popularity. An innovative multimedia total exposure model, CalTOX, was used to calculate the health risks for two target populations, before and after the introduction of Bt cotton and HT soybean. Major results include the quantification of incremental lifetime cancer risk based on a time-weighted average exposure, and the quantification of hazard ratios for non-cancer effects based on the maximum exposure rate value, both computed over the exposure duration. Results show that human health risks are not intuitively and necessarily reduced with the reduction of pesticide use. For example, more trifluralin was used after the introduction of HT soybeans in Iowa and Minnesota, leading to higher risks. Moreover, the general population may have larger exposures to pesticides when compared with the population living in areas where pesticides are actually applied. This may occur because exposure to pesticides is not only dependent on geographical distance from the contaminated area, but also strongly dependent on other factors, such as the characteristic travel distance and environmental persistence.  相似文献   

    11.
    Case-control data on childhood leukemia in Los Angeles County were reanalyzed with residential magnetic fields predicted from the wiring configurations of nearby transmission and distribution lines. As described in a companion paper, the 24-h means of the magnetic field's magnitude in subjects' homes were predicted by a physically based regression model that had been fitted to 24-h measurements and wiring data. In addition, magnetic field exposures were adjusted for the most likely form of exposure assessment errors: classic errors for the 24-h measurements and Berkson errors for the predictions from wire configurations. Although the measured fields had no association with childhood leukemia (P for trend=.88), the risks were significant for predicted magnetic fields above 1.25 mG (odds ratio=2.00, 95% confidence interval=1.03-3.89), and a significant dose-response was seen (P for trend=.02). When exposures were determined by a combination of predictions and measurements that corrects for errors, the odds ratio (odd ratio=2.19, 95% confidence interval=1.12-4.31) and the trend (p =.007) showed somewhat greater significance. These findings support the hypothesis that magnetic fields from electrical lines are causally related to childhood leukemia but that this association has been inconsistent among epidemiologic studies due to different types of exposure assessment error. In these data, the leukemia risks from a child's residential magnetic field exposure appears to be better assessed by wire configurations than by 24-h area measurements. However, the predicted fields only partially account for the effect of the Wertheimer-Leeper wire code in a multivariate analysis and do not completely explain why these wire codes have been so often associated with childhood leukemia. The most plausible explanation for our findings is that the causal factor is another magnetic field exposure metric correlated to both wire code and the field's time-averaged magnitude.  相似文献   

    12.
    A physically based model for residential magnetic fields from electric transmission and distribution wiring was developed to reanalyze the Los Angeles study of childhood leukemia by London et al. For this exposure model, magnetic field measurements were fitted to a function of wire configuration attributes that was derived from a multipole expansion of the Law of Biot and Savart. The model parameters were determined by nonlinear regression techniques, using wiring data, distances, and the geometric mean of the ELF magnetic field magnitude from 24-h bedroom measurements taken at 288 homes during the epidemiologic study. The best fit to the measurement data was obtained with separate models for the two major utilities serving Los Angeles County. This model's predictions produced a correlation of 0.40 with the measured fields, an improvement on the 0.27 correlation obtained with the Wertheimer-Leeper (WL) wire code. For the leukemia risk analysis in a companion paper, the regression model predicts exposures to the 24-h geometric mean of the ELF magnetic fields in Los Angeles homes where only wiring data and distances have been obtained. Since these input parameters for the exposure model usually do not change for many years, the predicted magnetic fields will be stable over long time periods, just like the WL code. If the geometric mean is not the exposure metric associated with cancer, this regression technique could be used to estimate long-term exposures to temporal variability metrics and other characteristics of the ELF magnetic field which may be cancer risk factors.  相似文献   

    13.
    Question: Understanding the aerial movement of seed is of great significance to the management of native and invasive plant species, but has proven difficult to measure. Here we examine how a more quantitative approach to measuring the aerial movement of seed can be achieved. Location: SE Australia. Methods: We describe a novel seed trap (the ‘Melbourne trap’), for which the proportion of free‐stream airflow through the trap can be measured, allowing a more quantitative approach to measuring aerial seed movement. We assessed airflow through the Melbourne trap in a wind tunnel and describe how this information, along with measurements of wind speed and direction, can now be used to derive seed density per volume of airflow. We compare the seed capture and retention efficiency of the Melbourne trap with two simpler and cheaper trap designs, bucket traps and sticky traps. Results: Melbourne and bucket traps captured significantly more species than sticky traps. Seed catch was dominated numerically by Lachnagrostis filiformis (G. Forst.) Trin. Melbourne traps proved more effective than sticky traps, but not bucket traps, in capturing L. filiformis, based on intake area. For all other seeds, Melbourne traps were more effective than both bucket and sticky traps. Conclusion: The Melbourne trap design is a significant advance in quantifying seed dispersal by wind. Melbourne traps will improve the capacity and accuracy of studies that seek to: (i) quantify seed fluxes across landscapes boundaries; (ii) assess directionality of dispersal; (iii) understand processes controlling seed release; and (iv) compare dispersal in wind and water.  相似文献   

    14.
    This article examines "wire configuration coding" as used to estimate relative residential AC magnetic field exposure in epidemiological studies--and the need to alter such coding for time or locations other than those in which the code was developed. Effects of different secondary wire practices are particularly examined.  相似文献   

    15.
    A study was carried out in 1990 to guide the development of a protocol for assessing residential exposures of children to time-weighted-average (TWA) power-frequency magnetic fields. The principal goal of this dosimetry study was to determine whether area (i.e., spot and/or 24 h) measurements of power-frequency magnetic fields in the residences and in the schools and daycare centers of 29 children (4 months through 8 years of age) could be used to predict their measured personal 24-h exposures. TWA personal exposures, measured with AMEX-3D meters worn by subjects, were approximately log-normally distributed with both residential and nonresidential geometric means of 0.10 μT (1.0 mG). Between-subjects variability in residential personal exposure levels (geometric standard deviation of 2.4) was substantially greater than that observed for nonresidential personal exposure levels (1.4). The correlation between log-transformed residential and total personal exposure levels was 0.97. Time-weighted averages of the magnetic fields measured in children's bedrooms, family rooms, living rooms, and kitchens were highly correlated with residential personal exposure levels (r = 0.90). In general, magnetic field levels measured in schools and daycare centers attended by subjects were smaller and less variable than measured residential fields and were only weakly correlated with measured nonresidential personal exposures. The final measurement protocol, which will be used in a large US study examining the relationship between childhood leukemia and exposure to magnetic fields, contains the following elements: normal- and low-power spot magnetic field measurements in bedrooms occupied by subjects during the 5 years prior to the date of diagnosis for cases or the corresponding date for controls; spot measurements under normal and low power-usage conditions at the centers of the kitchen and the family room; 24-h magnetic-field recordings near subjects' beds; and wire coding using the Wertheimer-Leeper method. © 1994 Wiley-Liss, Inc.
  • 1 This article is a US Government work and, as such, is in the public domain in the United States of America.
  •   相似文献   

    16.
    17.
    This study sought to estimate the relative contribution of exposure to 50 Hz magnetic fields experienced at home, at work/school, or elsewhere to the total exposure over 24 hr. Personal exposure meters were carried by 97 adults and children in the Stockholm area. About half of the subjects lived close (<50 m) to a transmission line and half far (>100 m) away. Spot measurements and calculations for the residential exposure were also made. For subjects living<50 m from the line, the exposure at home contributed about 80% of the total magnetic field exposure, measured in mT-hours. Adults living far away experienced only 38% of the total exposure at home, but children still received 55%. Subjects with low time-weighted average (TWA) exposure both at home and at work spent 84% of their time in fields <0.1 microT, and those with high TWA at both locations spent 69% of their time in fields > or = 0.2 microT. This contrast was diluted if only exposure at one location was considered. For spot measurements and calculations of the residential exposure, both sensitivity and specificity was good. However, the intermediate field exposure category (0.1-0.19 microT) showed poor correlation to the 24 hr personal measurements.  相似文献   

    18.
    In Hungary it is typical that 10/04 kV transformer stations are being installed in multistory residential and office buildings. Magnetic fields (MFs) up to several tens of microT have been measured in apartments close to transformers. The aim of the present study was to provide systematic assessment of MF exposure of residents living above transformer stations. Out of 41 addresses provided by the electricity supplier, current load of 21 transformers and MF in 21 apartments was measured. Spot MFs at 1 m height and time weighted average 24 h MF exposure at bed height was measured. All-day personal MF exposure was measured at waist and HOME exposure was calculated. BED exposure was measured at bed height. Participants kept a time-activity diary. The time-weighted average 24 h MF exposure (3.03 microT) exceeded the usual residential exposure (<0.2 microT). The mean HOME and BED personal exposure above transformers was 0.825 and 1.033 microT, respectively. Our study provides exposure assessment of a cohort with a wider exposure range, compared to power-line epidemiological studies.  相似文献   

    19.
    Rats were subjected to 4 h continuous and intermittent exposure to vinyl chloride (VC) at the time-weighted average concentration of 50,000 mg/m3. Prior to exposure, half of the animals obtained water, whereas the other half 0.1% sodium phenobarbital (PB) solution for seven consecutive days. The studies were focussed on: body weight, liver weight, activity of enzymes in the blood serum, activity of glutathione S-transferase in the liver cytoplasmatic and microsomal fraction, content of free non-protein sulfhydryl groups (NPSH) in the liver and urinary excretion of thiodiglycolic acid (TDGA). VC exposure, both continuous and intermittent, resulted in a decrease of body weight, NPSH depletion in the liver and TDGA urinary excretion. PB effects were manifested by the persistent decrease in rats' body weight, increase in the liver weight, increase in the cytoplasmatic activity of glutathione S-transferase in the liver and increase in TDGA urinary excretion. With none of the tested parameters, except TDGA, statistically significant differences between the continuous and intermittent VC exposure at the same time-weighted average concentration of 50,000 mg/m3, were found. TDGA urinary excretion was higher in rats poisoned in continuous exposure, as compared to the intermittent one.  相似文献   

    20.
    Daily routine 3 p.m. meteorological data for Melbourne, Victoria, were processed to provide estimates of maximum forest fire danger index (including soil-water deficit), potential number of days for failure of fire suppression for given quantities of fuel, and potential number of days for optimal prescribed fuel reduction burning in eucalypt forests given the same quantities of fuel. Although two models for estimating soil dryness gave widely different results, the effect of these differences on the value of the McArthur forest fire danger index (FFDI) was relatively small overall. However, over the 28 years of record, the number of ‘extreme’ days given using the Mount dryness index was 50% greater than that given by the Keetch-Byram index. The number of forest fires in Victoria (as a whole) was found to be related to 3 p.m. FFDI (for Melbourne) and to the incidence of weekends or public holidays. Potentially, bushfires near Melbourne would be ‘uncontrollable’; that is, with an intensity greater than 4000 kW m-1 on level ground, on an average of about 100 days per year (at 3 p.m.) if ignition were to occur where litter fuel weights were about 301 ha-1. However, if fuel weights were less than 81 ha-1, the potential number of ‘uncontrollable’ fires would be near zero. Using equations to predict conditions ideally suited to safe fuel reduction burning at 3 p.m. the average number of appropriate days per year increased from zero at a fuel weight of near 71 ha-1 to a maximum of 14 at 15 t ha-1. The extent to which the models used in this study are accurate is arguable so further work is needed.  相似文献   

    设为首页 | 免责声明 | 关于勤云 | 加入收藏

    Copyright©北京勤云科技发展有限公司  京ICP备09084417号