首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Abstract

The in vitro replication of DNA, principally using the polymerase chain reaction (PCR), permits the amplification of defined sequences of DNA. By exponentially amplifying a target sequence, PCR significantly enhances the probability of detecting target gene sequences in complex mixtures of DNA. It also facilitates the cloning and sequencing of genes. Amplification of DNA by PCR and other newly developed methods has been applied in many areas of biological research, including molecular biology, biotechnology, and medicine, permitting studies that were not possible before. Nucleic acid amplification has added a new and revolutionary dimension to molecular biology. This review examines PCR and other in vitro nucleic acid amplification methodologies—examining the critical parameters and variations and their widespread applications—giving the strengths and limitations of these methodologies.  相似文献   

2.
QuantiLyse: reliable DNA amplification from single cells   总被引:2,自引:0,他引:2  
Amplification of DNA sequencesfrom single cells via PCR is increasingly used in basic research and clinical diagnostics but remains technically difficult. We have developed a cell lysis protocol that uses an optimized proteinase K solution, named QuantiLyse and permits reliable amplification from individual cells. This protocol was compared to other published methods by means of real-time PCR with molecular beacons. The results demonstrate that QuantiLyse treatment of single lymphocytes renders gene targets more availablefor amplification than other published proteinase K methods or lysis in water. QuantiLyse and an optimized alkaline lysis were equally effective in terms of target availability, although QuantiLyse offers greaterflexibility, as it does not require neutralization and can comprise a higher percentage of the final PCR volume. Maximum gene target availability is also obtained following QuantiLyse treatment of samples containing up to 10000 cells (the largest number tested). Thus, QuantiLyse maximizes the chances that targeted DNA sequences will be available for amplification during the first cycle of PCR, thereby reducing the variability among replicate reactions as well as the likelihood of amplification failure or allele drop-out. QuantiLyse will be useful in a range of investigations aimed at gene detection in small numbers of cells.  相似文献   

3.
In the last decade, nucleic acid‐based methods gradually started to replace or complement the culture‐based methods and immunochemical assays in routine laboratories involved in food control. In particular, real‐time polymerase chain reaction (PCR) was technically developed to the stage of good speed, sensitivity and reproducibility, at minimized risk of carry‐over contamination. Basic advantages provided by nucleic acid‐based methods are higher speed and added information, such as subspecies identification, information on the presence of genes important for virulence or antibiotic resistance. Nucleic acid‐based methods are attractive also to detect important foodborne pathogens for which no classical counterparts are available, namely foodborne pathogenic viruses. This review briefly summarizes currently available or developing molecular technologies that may be candidates for involvement in microbiological molecular methods in the next decade. Potential of nonamplification as well as amplification methods is discussed, including fluorescent in situ hybridization, alternative PCR chemistries, alternative amplification technologies, digital PCR and nanotechnologies.  相似文献   

4.
5.
Kong F  Gilbert GL 《Nature protocols》2006,1(6):2668-2680
Combining multiplex PCR, sequentially, with reverse line blot hybridization (mPCR/RLB) is a convenient, objective way to identify up to 43 targets in 43 individual specimens simultaneously (using a 45-lane membrane format). It is more flexible and less expensive than DNA microarray. The number of targets is adequate for epidemiological and most clinical diagnostic applications; based on the same target (43) and specimen numbers (43), it is much more practical than conventional uniplex PCR (uPCR) and mPCR. We have used the protocol to identify and subtype bacteria, viruses and fungi and identify pathogens in clinical specimens; potentially, it could be used for many other applications, such as detection of mutations in, or identification of alleles of, eukaryotic genes. Development of each assay involves (i) careful primer and probe design, based on literature and sequence database searches, which are critical to success of the assay; and (ii) bench-top evaluation, using known samples, controls and dilution series, to confirm sensitivity, specificity and reproducibility. The assay takes about one and half working days to complete; about 4 h for the mPCR and 6 h for the RLB, including a total of 4 h 'hands-on' time.  相似文献   

6.
Herein we present Gene-Collector, a method for multiplex amplification of nucleic acids. The procedure has been employed to successfully amplify the coding sequence of 10 human cancer genes in one assay with uniform abundance of the final products. Amplification is initiated by a multiplex PCR in this case with 170 primer pairs. Each PCR product is then specifically circularized by ligation on a Collector probe capable of juxtapositioning only the perfectly matched cognate primer pairs. Any amplification artifacts typically associated with multiplex PCR derived from the use of many primer pairs such as false amplicons, primer-dimers etc. are not circularized and degraded by exonuclease treatment. Circular DNA molecules are then further enriched by randomly primed rolling circle replication. Amplification was successful for 90% of the targeted amplicons as seen by hybridization to a custom resequencing DNA micro-array. Real-time quantitative PCR revealed that 96% of the amplification products were all within 4-fold of the average abundance. Gene-Collector has utility for numerous applications such as high throughput resequencing, SNP analyses, and pathogen detection.  相似文献   

7.
Infectious hypodermal and hematopoietic necrosis virus (IHHNV) is a single-stranded DNA virus that causes developmental and growth abnormalities in Pacific white shrimp Litopenaeus vannamei (also known as Penaeus vannamei). Nucleic acid based methods such as in situ hybridization (ISH) and PCR have been commonly used for IHHNV detection. Ramification amplification (RAM), an isothermal nucleic acid amplification approach, was used in this study to detect IHHNV in L. vannamei. RAM offers many advantages over PCR, including simple procedures and short detection time, and is labor-saving and cost-effective. RAM exponentially amplifies a circular oligonucleotide amplicon (C probe) after a target-specific ligation step through sequential primer extension and strand displacement processes. The conditions of an IHHNV RAM assay were optimized using artificial templates and targets prior to application. Using DNA of IHHNV-infected L. vannamei as targets, results revealed that RAM amplified target DNA with similar sensitivity as PCR. RAM offers competitive levels of speed, simplicity and sensitivity among various pathogen diagnostic methods.  相似文献   

8.
Strategies for signal amplification in nucleic acid detection   总被引:3,自引:0,他引:3  
Many aspects of molecular genetics necessitate the detection of nucleic acid sequences. Current approaches involving target amplification (in situ PCR, Primed in situ Labeling, Self-Sustained Sequence Replication, Strand Displacement Amplification), probe amplification (Ligase Chain Reaction, Padlock Probes, Rolling Circle Amplification) and signal amplification (Tyramide Signal Amplification, Branched DNA Amplification) are summarized in the present review, together with their advantages and limitations.  相似文献   

9.
Multiplex PCR/Reverse Line Blot Hybridization assay allows the detection of up to 43 molecular targets in 43 samples using one multiplex PCR reaction followed by probe hybridization on a nylon membrane, which is re-usable. Probes are 5'' amine modified to allow fixation to the membrane. Primers are 5'' biotin modified which allows detection of hybridized PCR products using streptavidin-peroxidase and a chemiluminescent substrate via photosensitive film. With low setup and consumable costs, this technique is inexpensive (approximately US$2 per sample), high throughput (multiple membranes can be processed simultaneously) and has a short turnaround time (approximately 10 hours).The technique can be utilized in a number of ways. Multiple probes can be designed to detect sequence variation within a single amplified product, or multiple products can be amplified simultaneously, with one (or more) probes used for subsequent detection. A combination of both approaches can also be used within a single assay. The ability to include multiple probes for a single target sequence makes the assay highly specific.Published applications of mPCR/RLB include detection of antibiotic resistance genes1,2, typing of methicillin-resistant Staphylococcus aureus3-5 and Salmonella sp6, molecular serotyping of Streptococcus pneumoniae7,8, Streptococcus agalactiae9 and enteroviruses10,11, identification of Mycobacterium sp12, detection of genital13-15 and respiratory tract16 and other17 pathogens and detection and identification of mollicutes18. However, the versatility of the technique means the applications are virtually limitless and not restricted to molecular analysis of micro-organisms.The five steps in mPCR/RLB are a) Primer and Probe design, b) DNA extraction and PCR amplification c) Preparation of the membrane, d) Hybridization and detection, and e) Regeneration of the Membrane.  相似文献   

10.
A simple method is presented to circumvent laborious and time consuming electrophoretic separations of specific PCR amplification products. Specific target DNA is amplified using nucleotides labelled with DIG-dUTP or biotin-dCTP. The labelled PCR products are separated from unincorporated nucleotides or oligonucleotides by using a positively charged DEAE cellulose matrix. Amplification products are visualized directly in the matrix using immunoenzymatic methods or streptavidin-conjugated enzymes. The detection process can be carried out within 2 h, allows the processing of large sample sizes and can potentially be automated.  相似文献   

11.
Principle of LAMP method--a simple and rapid gene amplification method   总被引:3,自引:0,他引:3  
Ushikubo H 《Uirusu》2004,54(1):107-112
So far nucleic acid test (NAT) has been employed in various fields, including infectious disease diagnoses. However, due to its complicated procedures and relatively high cost, it has not been widely utilized in many actual diagnostic applications. We have therefore developed a simple and rapid gene amplification technology, Loop-mediated Isothermal Amplification (LAMP) method, which has shown prominent results of surpassing the performance of the conventional gene amplification methods. LAMP method acquires three main features: (1) all reaction can be carried out under isothermal conditions; (2) the amplification efficiency is extremely high and tremendous amount of amplification products can be obtained; and (3) the reaction is highly specific. Furthermore, developed from the standard LAMP method, a rapid LAMP method, by adding in the loop primers, can reduce the amplification time from the previous 1 hour to less than 30 minutes. Enormous amount of white precipitate of magnesium pyrophosphate is produced as a by-product of the amplification, therefore, direct visual detection is possible without using any reaction indicators and detection equipments. We believe LAMP technology, with the integration of these features, can rightly apply to clinical genetic testing, food and environmental analysis, as well as NAT in different fields.  相似文献   

12.
Deletions in mitochondrial DNA are a common cause of mitochondrial disorders. The molecular diagnosis of mtDNA deletions for years was based on Southern hybridization later replaced by PCR methods such as PCR with primers specific for a particular deletion (mainly the so-called common deletion of 4977bp) and long PCR. In order to evaluate the usefulness of MLPA (Multiplex Ligation-dependent Probe Amplification) in molecular diagnosis of large scale mtDNA deletions we compare four diagnostic methods: Southern hybridization, PCR, long-PCR and MLPA in a group of 16 patients with suspected deletions. Analysis was performed on blood, muscle and in one case hepatic tissue DNA. The MLPA was not able to confirm all the deletions detected by PCR methods, but due to its relative ease of processing, minimal equipment, low costs and the additional possibility to detect frequent point mtDNA mutations in one assay it is worth considering as a screening method. We recommend to always confirm MLPA results by PCR methods.  相似文献   

13.
Point-of-care nucleic acid testing for infectious diseases   总被引:1,自引:0,他引:1  
Nucleic acid testing for infectious diseases at the point of care is beginning to enter clinical practice in developed and developing countries; especially for applications requiring fast turnaround times, and in settings where a centralized laboratory approach faces limitations. Current systems for clinical diagnostic applications are mainly PCR-based, can only be used in hospitals, and are still relatively complex and expensive. Integrating sample preparation with nucleic acid amplification and detection in a cost-effective, robust, and user-friendly format remains challenging. This review describes recent technical advances that might be able to address these limitations, with a focus on isothermal nucleic acid amplification methods. It briefly discusses selected applications related to the diagnosis and management of tuberculosis, HIV, and perinatal and nosocomial infections.  相似文献   

14.
T4 DNA ligase is one of the workhorses of molecular biology and used in various biotechnological applications. Here we report that this ligase, unlike Escherichia coli DNA ligase, Taq DNA ligase and Ampligase, is able to join the ends of single-stranded DNA in the absence of any duplex DNA structure at the ligation site. Such nontemplated ligation of DNA oligomers catalyzed by T4 DNA ligase occurs with a very low yield, as assessed by quantitative competitive PCR, between 10(-6) and 10(-4) at oligonucleotide concentrations in the range 0.1-10 nm, and thus is insignificant in many molecular biological applications of T4 DNA ligase. However, this side reaction may be of paramount importance for diagnostic detection methods that rely on template-dependent or target-dependent DNA probe ligation in combination with amplification techniques, such as PCR or rolling-circle amplification, because it can lead to nonspecific background signals or false positives. Comparison of ligation yields obtained with substrates differing in their strandedness at the terminal segments involved in ligation shows that an acceptor duplex DNA segment bearing a 3'-hydroxy end, but lacking a 5'-phosphate end, is sufficient to play a role as a cofactor in blunt-end ligation.  相似文献   

15.
16.
Amplification of source DNA is a nearly universal requirement for molecular biology applications. The primary methods currently available to researchers are limited to in vivo amplification in Escherichia coli hosts and the polymerase chain reaction. Rolling-circle DNA replication is a well-known method for synthesis of phage genomes and recently has been applied as rolling circle amplification (RCA) of specific target sequences as well as circular vectors used in cloning. Here, we demonstrate that RCA using random hexamer primers with 29 DNA polymerase can be used for strand-displacement amplification of different vector constructs containing a variety of insert sizes to produce consistently uniform template for end-sequencing reactions. We show this procedure to be especially effective in a high-throughput plasmid production sequencing process. In addition, we demonstrate that whole bacterial genomes can be effectively amplified from cells or small amounts of purified genomic DNA without apparent bias for use in downstream applications, including whole genome shotgun sequencing.  相似文献   

17.
18.
BACKGROUND: Molecular diagnostic methods can complement existing tools to improve the diagnosis of malaria. However, they require good laboratory infrastructure thereby restricting their use to reference laboratories and research studies. Therefore, adopting molecular tools for routine use in malaria endemic countries will require simpler molecular platforms. The recently developed loop-mediated isothermal amplification (LAMP) method is relatively simple and can be improved for better use in endemic countries. In this study, we attempted to improve this method for malaria diagnosis by using a simple and portable device capable of performing both the amplification and detection (by fluorescence) of LAMP in one platform. We refer to this as the RealAmp method. METHODOLOGY AND SIGNIFICANT FINDINGS: Published genus-specific primers were used to test the utility of this method. DNA derived from different species of malaria parasites was used for the initial characterization. Clinical samples of P. falciparum were used to determine the sensitivity and specificity of this system compared to microscopy and a nested PCR method. Additionally, directly boiled parasite preparations were compared with a conventional DNA isolation method. The RealAmp method was found to be simple and allowed real-time detection of DNA amplification. The time to amplification varied but was generally less than 60 minutes. All human-infecting Plasmodium species were detected. The sensitivity and specificity of RealAmp in detecting P. falciparum was 96.7% and 91.7% respectively, compared to microscopy and 98.9% and 100% respectively, compared to a standard nested PCR method. In addition, this method consistently detected P. falciparum from directly boiled blood samples. CONCLUSION: This RealAmp method has great potential as a field usable molecular tool for diagnosis of malaria. This tool can provide an alternative to conventional PCR based diagnostic methods for field use in clinical and operational programs.  相似文献   

19.
Identifying low-abundance mutations within wild-type DNA is important in several fields of medicine, including cancer, prenatal diagnosis and infectious diseases. However, utilizing the clinical and diagnostic potential of rare mutations is limited by sensitivity of the molecular techniques employed, especially when the type and position of mutations are unknown. We have developed a novel platform that incorporates a synthetic reference sequence within a polymerase chain reaction (PCR) reaction, designed to enhance amplification of unknown mutant sequences during COLD-PCR (CO-amplification at Lower Denaturation temperature). This new platform enables an Improved and Complete Enrichment (ice-COLD-PCR) for all mutation types and eliminates shortcomings of previous formats of COLD-PCR. We evaluated ice-COLD-PCR enrichment in regions of TP53 in serially diluted mutant and wild-type DNA mixtures. Conventional-PCR, COLD-PCR and ice-COLD-PCR amplicons were run in parallel and sequenced to determine final mutation abundance for a range of mutations representing all possible single base changes. Amplification by ice-COLD-PCR enriched all mutation types and allowed identification of mutation abundances down to 1%, and 0.1% by Sanger sequencing or pyrosequencing, respectively, surpassing the capabilities of other forms of PCR. Ice-COLD-PCR will help elucidate the clinical significance of low-abundance mutations and our understanding of cancer origin, evolution, recurrence-risk and treatment diagnostics.  相似文献   

20.
We developed an efficient method of isothermally amplifying DNA termed ICAN, Isothermal and Chimeric primer-initiated Amplification of Nucleic acids. This method allows the amplification of target DNA under isothermal conditions at around 55 degrees C using only a pair of 5'-DNA-RNA-3' chimeric primers, a thermostable RNaseH and a DNA polymerase with strong strand-displacing activity. ICAN is capable of amplifying DNA at least several times greater than the amount produced with PCR by increasing primer concentration. This method would be applicable for on-site DNA detection including gene diagnosis, and would also be suitable for 'real time' detection when combined with a cycling probe.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号