首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
F2-isoprostanes (F2-iPs) comprise four classes of isomers produced non-enzymatically by free radical attack on arachidonic acid, a component of the cell membrane. This paper describes a new method for the quantification of F2-isoprostanes in urine samples from thoroughly diagnosed Alzheimer's disease (AD) patients. The sample pretreatment consisted of liquid extraction of 900 microl urine with diethyl ether, its subsequent evaporation, and finally, reconstitution in 50 microl water. Of this, 20 microl was injected into a HPLC system with a 15 mm x 1 mm porous graphitic carbon column coupled to a triple quadrupole mass spectrometer running in negative electrospray ionization mode. The F2-isoprostanes were separated in 15 min using a linear solvent gradient comprising water, methanol, acetonitrile and ammonium hydroxide at a pH of 9.5. The average recovery obtained was approximately 75%. The limit of detection (3S/N) was calculated for iPF2alpha-III to be 0.7 pg injected on column, corresponding to 0.1 nM. The average level of iPF2alpha was 241 +/- 163 pg/mg creatinine in the urine samples from AD patients (average +/- standard deviation). The corresponding control values were 216 +/- 101 pg/mg creatinine, i.e. no statistically significant difference was noticed. No correlation pattern specific to Alzheimer's disease was revealed by principal component analysis of the isoprostane peaks obtained either. The results from this study support earlier findings that levels of peripheral isoprostanes are not increased in patients with Alzheimer's disease.  相似文献   

2.
A sample treatment procedure and high-sensitive liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) method for quantitative determination of fexofenadine in human plasma was developed for a microdose clinical trial with a cold drug, i.e., a non-radioisotope-labeled drug. Fexofenadine and terfenadine, as internal standard, were extracted from plasma samples using a 96-well solid-phase extraction plate (Oasis HLB). Quantitation was performed on an ACQUITY UPLC system and an API 5000 mass spectrometer by multiple reaction monitoring. Chromatographic separation was achieved on an XBridge C18 column (100 mm x 2.1 mm i.d., particle size 3.5 microm) using acetonitrile/2 mM ammonium acetate (91:9, v/v) as the mobile phase at a flow rate of 0.6 ml/min. The analytical method was validated in accordance with the FDA guideline for validation of bioanalytical methods. The calibration curve was linear in the range of 10-1000 pg/ml using 200 microl of plasma. Analytical method validation for the clinical dose, for which the calibration curve was linear in the range of 1-500 ng/ml using 20 microl of plasma, was also conducted. Each method was successfully applied for making determinations in plasma using LC/ESI-MS/MS after administration of a microdose (100 microg solution) and a clinical dose (60 mg dose) in eight healthy volunteers.  相似文献   

3.
The present work reports capillary liquid chromatographic column switching methodology tailored for fast, sensitive and selective determination of 1-hydroxypyrene (1-OHP) in human urine using micro-electrospray ionization time-of-flight mass spectrometric detection. Samples (100 microl) of deconjugated, water diluted and filtered urine samples were loaded onto a 150 microm I.D.x 30 mm 10 microm Kromasil C(18) pre-column, providing on-line sample clean-up and analyte enrichment, prior to back flushed elution onto a 150 microm I.D.x 100 mm 3.5 microm Kromasil C(18) analytical column. Loading flow rates up to 100 microl/min in addition to the use of isocratic elution by a mobile phase composition of acetonitrile/water (70/30, v/v) containing 5 mM ammonium acetate provided elution of 1-OHP within 5.5 min and a total analysis time of less than 15 min with manual operation. Ionization was performed in the negative mode and 1-OHP was observed as [M-H](-) at m/z 217.08. The method was validated over the concentration range 0.2-40 ng/ml 1-OHP in pre-treated urine, yielding a coefficient of correlation of 0.997. The within-assay (n=6) and between-assay (n=6) precisions were in the range 6.4-7.3 and 7.0-8.1%, respectively, and the recoveries were in the range 96.2-97.5 within the investigated concentration range. The method mass limit of detection was 2 pg, corresponding to a 1-OHP concentration limit of detection of 20 pg/ml (0.09 nmol/l) diluted urine or 0.3 ng/ml (1.35 nmol/l) urine.  相似文献   

4.
A liquid chromatographic method with UV detection for the quantification of nimesulide (N) and hydroxynimesulide (M1) in rat plasma, cerebrospinal fluid (CSF) and brain tissue is reported. Plasma samples (250 microl) and brain homogenates added with the right amount of the internal standard (I.S., 2'-(cyclohexyloxy)-4'-nitrophenyl methanesulphonanilide, NS398) are extracted on C(18) disposable cartridges by solid-phase extraction (SPE), while CSF samples are analyzed without any extraction. The separation is performed at room temperature on a Waters Symmetry C(18) 3.5 microm (150x4.6 mm I.D.) column with acetonitrile-sodium citrate buffer pH 3.00 (53:47, v/v) as mobile phase, at a flow-rate of 1.1 ml/min and detection at 240 nm. The retention times are 3.3, 6.0 and 9.9 min for M1, N and I.S., respectively. The lower limits of quantitation for either nimesulide and M1 are 25 ng/ml for plasma, 20 ng/ml for CSF and 25 ng/g for brain tissue. The calibration curves are linear up to 10,000 ng/ml for plasma, 5000 ng/ml for CSF and 5000 ng/g for brain tissue. This new assay can be applied to the study of the role of nimesulide in the modulation of neuroinflammatory processes.  相似文献   

5.
A sensitive LC-MS-MS assay for the quantitative determination of bromocriptine has been developed and validated and is described in this work. The assay involved the extraction of the analyte from 1 ml of human plasma using a solid phase extraction on Oasis MCX cartridges. Chromatography was performed on a Symmetry C18 (2.1 mm x 100 mm, 3.5 microm) column using a mobile phase consisting of 25:75:01 acetonitrile-water-formic acid with a flow rate of 250 microl/min. The linearity was within the concentration range of 2-500 pg/ml. The lower limit of quantification was 2 pg/ml. This method has been demonstrated to be an improvement over existing methods due to its greater sensitivity and specificity.  相似文献   

6.
We attempted to improve the extraction procedures to determine the F(2)-isoprostanes in plasma of umbilical cord arterial and venous blood by gas chromatography mass spectrometry. Plasma samples were deproteinized and hydrolyzed; free and esterified F(2)-isoprostanes were extracted by solid-phase extraction columns with citric acid/methanol/cyclohexane and ammonia solution/methanol and then derivatized by PFBBr and BSTFA. Concentrations of total plasma F(2)-isoprostanes eluted at the retention time of an internal standard of 8-iso-prostaglandin F(2alpha)-D(4) were quantified. The absolute recovery was 83+/-1.9% (95% confidence). Intraassay precision and interassay precision were lower than 1.0%. Analytical accuracy was 99.0+/-0.4% (95% confidence). Linearity, r(2), over the concentration range of 10 to 5000 pg/ml of spiked 8-iso-prostaglandin F(2alpha) in plasma was 0.9985. The method detection limit was 21 pg/ml (99% confidence) and the limit of quantitation was approximately 4 pg/ml. Analysis of 200 neonatal cord blood samples revealed few overlapping peaks causing interference in the elution of the F(2)-isoprostanes. With the use of an autosampler and one technician, 48 samples can be completed within 24h with 6h of actual hands-on work. This method could be potentially employed for routine analysis of plasma F(2)-isoprostanes in clinical laboratories.  相似文献   

7.
The chiral separation of norgestrel enantiomers using reversed-phase high-performance liquid chromatography (RP-HPLC) was studied with hydroxypropyl-beta-cyclodextrin (HP-beta-CD) as chiral mobile phase additive. The effect of mobile phase composition, concentration of HP-beta-CD and column temperature on enantioselective separation were investigated. The quantification properties of the developed RP-HPLC method were examined. A baseline separation of norgestrel enantiomers was achieved on a Agilent ZORBAX Eclipse XDB-C8 column (150 mm x 4.6 mm i.d., 5 microm). The mobile phase was a mixture of acetonitrile and phosphate buffer (pH 5.0, 20 mM) containing 25 mM HP-beta-CD (30:70, v/v) with a flow rate of 1.0 ml/min. The UV detector was set at 240 nm. Calibration curves were linear (n=8) in the range of 0.2-25 microg/ml, the limit of detection and quantitation were 0.10 and 0.20 microg/ml, respectively, for racemic norgestrel. The values of RSD of repeatability and intermediate precision for spiked sample were less than 4.8%. The method was successfully applied to the enantioselective determination of this drug in stereoselective skin permeation study.  相似文献   

8.
A sensitive, specific and reproducible method for the quantitative determination of kavain in human hair has been developed. The sample preparation involved a decontamination step of the hair with methylene chloride. The hair sample (about 50 mg) was incubated in 1 ml of methanol for 1 h, in an ultrasonic bath, in presence of 20 ng of methaqualone-d7 used as internal standard. The methanolic solution was evaporated to dryness, and the residue reconstituted by adding 30 microl of methanol. A 2 microl aliquot of the extract was injected onto the column (Optima5-MS capillary column, 5% phenyl-95% methylsiloxane, 30 m x 0.25 mm i.d. x 0.25 mm film thickness) of a Hewlett-Packard (Palo Alto, CA) gas chromatograph (5890). Kavain was detected by its parent ion at m/z 230 and daughter ions at m/z 111 and 202 through a Finnigan TSQ 700 MS/MS system. The assay was capable of detecting 30 pg/mg of kavain (limit of detection (LOD)). Linearity was observed for kavain concentrations ranging from 100 to 2000 pg/mg with a correlation coefficient of 0.998. Intra-day precision at 400 pg/mg was 13.7%. The analysis of a segment of hair, obtained from an occasional consumer, revealed the presence of kavain at the concentration of 418 pg/mg. A higher concentration (1708 pg/mg) was detected in the corresponding pubic hair.  相似文献   

9.
Voriconazole is a novel broad-spectrum antifungal agent. We developed an on-line LC-LC-MS-MS method for fully automated and direct analysis of voriconazole in raw human serum. After injection of human serum size-selective sample fractionation and analyte extraction was achieved using an extraction column (25 mm x 4 mm) packed with a restricted access material (RAM, LiChrospher ADS C(8), 25 microm). On-line transfer of voriconazole from the extraction column was followed by chromatography separation on a C(18) column. Detection was done by ESI-MS-MS. The total analysis time was 13 min, managed by parallel extraction and chromatographic separation. This LC-MS assay was fully validated. The lower limit of quantification was 0.05 microg/ml. The automated inline extraction of voriconazole described here eliminates the need for difficult and time-consuming sample pre-treatment. Other advantages of the new method are that only a small quantity (5 microl) of serum is needed and that the method is very specific.  相似文献   

10.
A GLP-validated, sensitive and specific LC-MS-MS method for the quantification of paclitaxel and its 6-alpha- and 3'-p-hydroxy metabolites is presented. A 0.400 ml plasma aliquot is spiked with a (13)C(6)-labeled paclitaxel internal standard and extracted with 1 ml methyl-tert.-butyl ether. The ether is evaporated and the residue is reconstituted in 130 microl of 30% aqueous acetonitrile (ACN) containing 0.1% trifluoroacetic acid. Isocratic HPLC analysis is performed by injecting 50 microl of the reconstituted material onto a 50x2.1 mm C(18) column with an ACN-water-acetic acid (50:50:0.1) mobile phase at 200 microl/min flow. Detection is by positive ion electrospray followed by multiple reaction monitoring of the following transitions: paclitaxel (854>509 u), 6-alpha-hydroxy paclitaxel (870>525 u), 3'-p-hydroxy paclitaxel (870>509 u) and internal standard (860>509 u). Quantification is by peak area ratio against the 13C(6) internal standard. The method range is 0.117-117 nM (0.1-100 ng/ml) for paclitaxel and both metabolites using a 0.400 ml human or dog plasma sample. Analysis time per sample is less than 5 min.  相似文献   

11.
A sensitive, specific and reproducible method for the quantitative determination of the anabolic metandienone in human hair has been developed. The preparation involved a decontamination step with methylene chloride. The hair sample (about 50 mg) was solubilised in 1 ml 1 M NaOH, 10 min at 95 degrees C, in presence of 2 ng of nandrolone-d(3) used as internal standard. The homogenate was neutralized and extracted using consecutively a solid-phase extraction (Isolute C(18) eluted with methanol) and a liquid-liquid extraction with pentane. The residue was derivatized by adding 5 microl MSTFA/NH(4)I/2-mercaptoethanol (250 microl; 5 mg; 15 microl) and 45 microl MSTFA, then incubated for 20 min at 60 degrees C. A 1 microl aliquot of derivatized extract was injected into the column (HP5-MS capillary column, 5% phenyl-95% methylsiloxane, 30 m x 0.32 mm i.d., 0.25 microm film thickness) of a Hewlett Packard (Palo Alto, CA, USA) gas chromatograph (6890 Series). Metandienone was identified using three transitions (its daughter ions at m/z 339 and 206 for the parent 444 and 191 for 206) using a Waters Quattro Micro MS-MS system. The transition m/z 444 to 206 has been used as quantification transition and the others as identification transitions. The assay was capable of detecting 2 pg/mg of metandienone when approximately 50 mg of hair material was processed. Linearity was observed for metandienone concentrations ranging from 2 to 500 pg/mg with a correlation coefficient of 0.9997. Intra-day and between-day precisions at 50 pg/mg were 13.4-16.5% and 22.0%, respectively, with an extraction recovery of 48%. The analysis of hair, cut into four segments, obtained from an athlete, revealed the presence of metandienone at the concentrations of 78, 7, 10 and 108 pg/mg in each segment of hair (0-1, 1-2, 2-3 and 3 cm to the tip).  相似文献   

12.
We have developed a sensitive, selective and reproducible reversed-phase high-performance liquid chromatography method coupled with electrospray ionization mass spectrometry (HPLC-ESI-MS) for the simultaneous quantification of midazolam (MDZ) and its major metabolite, 1'-hydroxymidazolam (1'-OHM) in a small volume (200 microl) of human plasma. Midazolam, 1'-OHM and 1'-chlordiazepoxide (internal standard) were extracted from alkalinised (pH 9.5) spiked and clinical plasma samples using a single step liquid-liquid extraction with 1-chlorobutane. The chromatographic separation was performed on a reversed-phase HyPURITY Elite C18 (5 microm particle size; 100 mm x 2.1mm i.d.) analytical column using an acidic (pH 2.8) mobile phase (water-acetonitrile; 75:25% (v/v) containing formic acid (0.1%, v/v)) delivered at a flow-rate of 200 microl/min. The mass spectrometer was operated in the positive ion mode at the protonated-molecular ions [M+l]+ of parent drug and metabolite. Calibration curves in spiked plasma were linear (r2 > or = 0.99) from 15 to 600 ng/ml (MDZ) and 5-200 ng/ml (1'-OHM). The limits of detection and quantification were 2 and 5 ng/ml, respectively, for both MDZ and 1'-OHM. The mean relative recoveries at 40 and 600 ng/ml (MDZ) were 79.4+/-3.1% (n = 6) and 84.2+/-4.7% (n = 8), respectively; for 1'-OHM at 30 and 200 ng/ml the values were 89.9+/-7.2% (n = 6) and 86.9+/-5.6% (n = 8), respectively. The intra-assay and inter-assay coefficients of variation (CVs) for MDZ were less than 8%, and for 1'-OHM were less than 13%. There was no interference from other commonly used antimalarials, antipyretic drugs and antibiotics. The method was successfully applied to a pharmacokinetic study of MDZ and 1'-OHM in children with severe malaria and convulsions following administration of MDZ either intravenously (i.v.) or intramuscularly (i.m.).  相似文献   

13.
We have developed and validated an assay, using liquid chromatography coupled with electrospray tandem mass spectrometry (LC-MS/MS), for the quantification of the novel protease inhibitors (PIs) atazanavir and tipranavir. The sample pre-treatment consisted of protein precipitation with a mixture of methanol and acetronitrile using 100 microl plasma for atazanavir and 50 microl for tipranavir. Chromatographic separation was achieved on an Inertsil ODS3 column (50 mm x 2.0 mm i.d., particle size 5 microm), with a quick stepwise gradient using an acetate buffer (pH 5) and methanol, at a flow rate of 0.5 ml/min. The analytical run time was 5.5 min. The triple quadrupole mass spectrometer operated in the positive ion-mode and multiple reaction monitoring (MRM) was used for drug quantification. The assay was linear over a concentration range of 0.05-10 microg/ml for atazanavir and 0.1-75 microg/ml for tipranavir. Saquinavir-d5 was used as internal standard. The intra- and inter-day coefficients of variation were less than 3.8% for atazanavir and less than 10.4% for tipranavir. Accuracies were within +/-7.3 and +/-7.2% for atazanavir and tipranavir, respectively. Both drugs were stable under various relevant storage conditions. The validated concentration ranges proved to be adequate to measure concentrations of human immunodeficiency virus type-1 (HIV-1)-infected individuals. The developed method could easily be combined with a previously developed LC-MS/MS assay for the quantification of protease inhibitors.  相似文献   

14.
Simultaneous determination of ribonucleoside and deoxyribonucleoside triphosphates in cells by HPLC is an analytical challenge since the concentration of dNTP present in mammalian cells is several orders of magnitude lower than the corresponding NTP. Hence, the quantitation of dNTP in cells is generally performed after selective oxidation or removal of the major NTP. The procedures reported so far are lengthy and cumbersome and do not enable the simultaneous determination of NTP. We report the development of a simple, direct HPLC method for the simultaneous determination of dNTP and NTP in colon carcinoma WiDr cell extracts using a stepwise gradient elution ion-pairing HPLC with uv detection at 260 nm and with a minimal chemical manipulation of cells. Exponentially growing WiDr cells were harvested by centrifugation, rinsed with phosphate-buffered saline, and carefully counted. The pellets were suspended in a known volume of ice-cold water and deproteinized with an equal volume of 6% trichloroacetic acid. The acid cell extracts (corresponding to 2. 5 x 10(6) cells/100 microl) were centrifuged at 13,000g for 10 min at 4 degrees C. The resulting supernatants were stored at -80 degrees C prior to analysis. Aliquots (100 microl) were neutralized with 4.3 microl saturated Na2CO3 solution prior the injection of 40 microl onto the HPLC column (injection speed 250 microl/min). Chromatographic separations were performed using two Symmetry C18 3. 5-microm (2 x 3.9 x 150 mm) columns (Waters), connected in series equipped with a Sentry guard column (3.9 x 20 mm i.d.) filled with the same packing material. The HPLC columns were kept at 30 degrees C. The mobile phase was delivered at a flow rate of 0.5 ml/min, with the following stepwise gradient elution program: % solvent A/solvent B, 100/0 at 0 min --> 100/0 at 1 min --> 36/64 at 5 min --> 31/69 at 90 min --> 31/69 at 105 min --> 0/100 at 106 min --> 0/100 at 120 min; 50/50 MeOH/solvent B from 121 to 130 min; 100% solvent A from 131 to 160 min. Solvent A contained 0.01 M KH2PO4, 0.01 M tetrabutylammonium chloride, and 0.25% MeOH and was adjusted to pH 7. 0 (550 microl 10 N NaOH for 1 liter solvent A). Solvent B consisted of 0.1 M KH2PO4, 0.028 M tetrabutylammonium chloride, and 30% MeOH and was neutralized to pH 7.0 (1.4 ml 10 N NaOH for 1 liter solvent B). Even though dNTPs are minor components of cell extracts, satisfactory regression coefficients were obtained for their calibration curves (r2 > 0.99) established with the addition-calibration methods up to 120 pmol/40-microl injection. The applicability of the method was demonstrated by in vitro studies of the modulation of NTP and dNTP pools in WiDr colon carcinoma cell lines exposed to various pharmacological concentrations of cytostatic drugs (i.e., FMdC, IUdR, gemcitabine). In conclusion, this optimized, simplified, analytical method enables the simultaneous quantitation of NTP and dNTP and may represent a valuable tool for the detection of minute alterations of cellular dNTP/NTP pools induced by anticancer/antiviral drugs and diseases.  相似文献   

15.
A sensitive, specific and reproducible method for the quantitative determination of methenolone in human hair has been developed. The sample preparation involved a decontamination step of the hair with methylene chloride. The hair sample (about 100 mg) was solubilized in 1 ml 1 M NaOH, 15 min at 95 degrees C, in presence of 1 ng testosterone-d3 used as internal standard. The homogenate was neutralized and extracted using consecutively a solid-phase (Isolute C18 eluted with methanol) and a liquid-liquid (pentane) extraction. The residue was derivatized by adding 50 microl MSTFA-NH4I-2-mercaptoethanol (1000:2:5, v/v/v), then incubated for 20 ml at 60 degrees C. A 1.5-microl aliquot of the derivatized extract was injected into the column (HP5-MS capillary column, 5% phenyl-95% methylsiloxane, 30 m x 0.25 mm I.D., 0.25 microm film thickness) of a Hewlett-Packard (Palo Alto, CA, USA) gas chromatograph (6890 Series). Methenolone was detected by its parent ion at m/z 446 and daughter ions at m/z 208 and 195 through a Finnigan TSQ 700 MS-MS system. The assay was capable of detecting 1 pg/mg of methenolone when approximately 100 mg hair material was processed. Linearity was observed for methenolone concentrations ranging from 2 to 100 pg/mg with a correlation coefficients of 0.965-0.981. Intra-day and between-day precisions at 2, 10 and 25 pg/mg were 10.9-14.1% and 13.7-16.8%, respectively, with an extraction recovery of 97.6%. The analysis of a strand of hair obtained from two bodybuilders, revealed the presence of methenolone at the concentrations of 7.3 and 8.8 pg/mg.  相似文献   

16.
A rapid and sensitive high-performance liquid chromatographic (HPLC) assay has been developed to allow determination of total (i.e. bound and unbound) and free (i.e. unbound) topotecan (TPT) in mouse plasma in the presence and absence of anti-TPT antibodies. The chromatographic analysis was carried out using reversed-phase isocratic elution with a Nova-Pak C18 column (3.9 mm x 150 mm, 4 microm) protected by a Nova-Pak C18 guard column (3.9 mm x 20 mm, 4 microm), where 10 mM KH(2)PO(4)-methanol-triethylamine (72:26:2 (v/v/v), pH 3.5) was used as the mobile phase. Topotecan was quantified with fluorescence detection using an excitation wavelength of 361 nm and an emission wavelength of 527 nm. The retention time for the internal standard, acridine, and TPT were 7.4 and 9.0 min, respectively. The lower limit of quantitation (LOQ) for TPT was determined as 0.02 ng in mouse plasma and mouse plasma ultrafiltrate, corresponding to a concentration of 1 ng/ml in 20 microl mouse plasma. The assay was shown to be linear over a concentration range of 1-500 ng/ml. The recoveries of free and total TPT from spiked mouse plasma were within 10% of theoretical values (assessed at 1, 20 and 500 ng/ml). The validated HPLC assay was applied to evaluate TPT pharmacokinetics following administration of TPT to Swiss Webster mice and to hyperimmunized and control BALB/c mice. The assay has been shown to be capable for measuring total and free TPT in mouse plasma with high sensitivity and will allow the testing of the effect of anti-TPT antibodies on the disposition of TPT.  相似文献   

17.
A rapid, sensitive and selective gas chromatographic method with flame ionization detection was developed for the determination of paraldehyde in small blood samples taken from children. Whole blood samples (300 microl) collected in a 3 ml Wheaton glass sample vial were spiked with acetone (internal standard: 15 ng) followed by addition of concentrated hydrochloric acid. The mixture was heated in the sealed airtight sample vial in a water bath (96 Celsius; 5 min) to depolymerize paraldehyde to acetaldehyde. A 2 ml aliquot of the headspace was analyzed by gas chromatography with flame ionization detector using a stainless steel column (3 m x 4 mm i.d.) packed with 10% Carbowax 20 M/ 2% KOH on 80/100 Chromosorb WAW. Calibration curves were linear from 1.0-20 microg (r2>0.99). The limit of detection was 1.5 microg/ml, while relative mean recoveries at 2 and 18 microg were 105.6 +/- 8.4 and 101.2 +/- 5.9%, respectively (n = 10 for each level). Intra- and inter-assay relative standard deviations at 2, 10 and 18 microg were <15%. There was no interference from other drugs concurrently used in children with severe malaria, such as anticonvulsants (diazepam, phenytoin, phenobarbitone), antipyretics/analgesics (paracetamol and salicylate), antibiotics (gentamicin, chloramphenicol, benzyl penicillin) and antimalarials (chloroquine, quinine, proguanil, cycloguanil, pyrimethamine and sulfadoxine). The method was successfully applied for pharmacokinetic studies of paraldehyde in children with convulsions associated with severe malaria.  相似文献   

18.
The aim of this study was to develop a rapid and sensitive HPLC method with UV detection for the estimation of imatinib from the plasma of patients with chronic myeloid leukemia (CML). The robustness of the method was checked by conducting first dose pharmacokinetics on blood samples from four patients who had been administered Gleevec (100 mg) in an oral dose. Samples were prepared in a simple and single step by precipitating the plasma proteins with methanol and injecting 50 microl aliquot from supernatant was subjected for analysis. Assay was conducted using a C8 column (250 mm x 4.6 mm, 5 microm particle size) under isocratic elution with 0.02 M potassium dihydrogen phosphate-acetonitrile (7:3, v/v) at a flow rate of 1 ml/min and detected using photodiode array at 265 nm. Calibration plots in spiked plasma were linear in a concentration range of 0.05-25 microg/ml. The inter and intra-day variation of standard curve was <4% (R.S.D.). This method could be a simple and quick method for the estimation of imatinib from the patient's plasma.  相似文献   

19.
A simple, sensitive, selective and reproducible method based on anion-exchange liquid chromatography with post-column derivatisation was developed for the determination of eflornithine (2-difluoromethyl-DL-ornithine; DFMO) in human plasma and cerebrospinal fluid. The 1-alkylthio-2-alkyl-isoindoles fluorescent derivative of the drug was separated from the internal standard (MDL 77246A) on an anion-exchange column (PRP-X300, 250x2.1 mm, 7-microm particle size: Hamilton, USA), with retention times of 6.9 and 10.7 min, respectively. Fluorescence detection was set at 430/340 nm (emission/excitation wavelength). The elution solvent consisted of a solution of 30 mM potassium dihydrogen phosphate buffer (pH 2.2) and acetonitrile (50:50, v/v), running through the column at a flow-rate of 0.3 ml/min. The chromatographic analysis was operated at 37 degrees C. Sample preparation for either plasma or CSF (100 microl) was done by single-step protein precipitation with 20% trichloroacetic acid after incubation at 4 degrees C for 1 h. Calibration curves for plasma (100, 200, 400, 600, 800 and 1200 nmol/100 microl, and 10, 20, 40, 80, 120 and 160 nmol/100 microl for the high and low concentration range curves, respectively) and CSF (1, 2, 4, 8, 16, 32 nmol/100 microl) were all linear with correlation coefficients better than 0.999. The precision of the method based on within-day repeatability and reproducibility (day-to-day variation) at high concentration range was below 15%, whereas at low concentration range was below 20% (% coefficient of variations: %C.V.) Good accuracy was observed for both the intra-day or inter-day assays, as indicated by the minimal deviation of mean values found with measured samples from that of the theoretical values (below +/-15 and +/-20% at high and low concentration range, respectively. The limit of quantification was accepted as 0.1 nmol using 100-microl samples. The mean recovery for DFMO and the internal standard were greater than 95%. The method was free from interference from commonly used drugs including antimalarials and antihelminthics. The method appears to be robust and has been applied to a pharmacokinetic study of DFMO in patients with African trypanosomiasis following oral doses of Ornidyl (Aventis Pharma, Frankfurt, Germany) at 500 mg/kg body weight (125 mg q.i.d.) for 14 days.  相似文献   

20.
A method based on cloud-point extraction (CPE) was developed to determine arbidol in rat plasma by high performance liquid chromatography separation and ultraviolet detection (HPLC-UV). The non-ionic surfactant Triton X-114 was chosen as the extract solvent. Variable parameters affecting the CPE efficiency were evaluated and optimized. A Zorbax SB-C(18) column (4.6 mm i.d. x 150 mm, 5 microm particle size) was used for isocratic elution separation at 40 degrees C with detection wavelength at 316 nm. Under the optimum conditions, the method was shown to be reproducible and reliable with intraday precision below 6.6%, interday precision below 8.8%, accuracy within +/-5.0% and mean extraction recovery more than 89.7%, which were all calculated using a range of spiked samples at three concentrations of 0.2, 2 and 16 microg/ml for arbidol in plasma. The linear range was from 0.08 to 20 microg/ml. After strict validation, the method was successfully applied to the pharmacokinetic study of arbidol in rats after oral and intravenous administration, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号