首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A radiometric assay for human growth hormone (HGH) was developed based on a polyclonal goat anti-HGH antiserum covalently coupled to nonsedimenting polyacrylamide particles. HGH can be specifically immunoextracted from sample volumes of up to 10 ml. Subsequently, bound HGH is identified and quantitatively measured by a 125I-labelled monoclonal anti-HGH antibody. The assay is insensitive to plasma proteins from 10 to greater than 90%, to changing NaCl and urea molarities and to pH ranges from 6 to 8. The sensitivity in the second incubation is 2 pg/tube, corresponding to a maximum sensitivity of 300 fg/ml of a sample volume of 10 ml (urine) or of 40 pg/ml, if a volume of 50 microliter (plasma) is assayed. In healthy children, a mean HGH excretion of 6.5 ng/24 h was found with a large interindividual range from undetectable to 37.4 ng. An important intraindividual night-to-night variation of HGH excretion was found in several subsequent first morning void samples in healthy children. The mean excretion in 13 HGH-deficient children was 0.9 ng/24 h off therapy and increased to a mean of 6.9 ng/24 h on therapy. In acromegalic patients, the excreted HGH amounted to 73-208 ng/24 h. Preliminary results suggest that the ultrasensitive assay applied to plasma and urine could be a considerable improvement of diagnosis and follow-up of disorders of HGH secretion.  相似文献   

2.
An assay is described which detects saxitoxin (STX) and tetrodotoxin (TTX) by their competitive displacement of [3H]saxitoxin from its receptor in rat brain membranes. The assay has a sensitivity of 0.15 ng STX/ml and 0.8 ng TTX/ml for buffer samples. The assay was also applied to detection of these toxins in unextracted human plasma and found to have a sensitivity of 0.5 ng STX/ml and 0.6 ng TTX/ml. The competitive displacement assay appears to be the most sensitive procedure yet for detection of STX and TTX.  相似文献   

3.
The sensitivity of solid-phase radioimmunoassay for the measurement of staphylococcal enterotoxin B (SEB) in foods was decreased by food constituents that react with rabbit anti-SEB with an equivalency of over 2 ng/ml. This activity was minimized by a conditioning step for anti-SEB and by removal of interfering compounds in the sample by extraction. The assay was a sequential solid-phase radioimmunoassay technique in which polystyrene test tubes were initially incubated with antisera and then with bovine serum albumin. The tubes were then conditioned with either a centrifuged aqueous cheese extract or, equally effective, reconstituted nonfat dry milk for 16 h at 4°C. Samples of milk or heat-treated and CHCl3-extracted cheese or chicken salad slurries were incubated in the assay tubes for 6 h at 37°C. The samples were replaced by 125I-labeled SEB and incubated for a further 2 to 4 h before the contents were removed and the tubes were washed and counted. A buffer solution containing known concentrations of toxin served as standards for assaying SEB in the food extracts. The entire assay can be accomplished within 24 h with a sensitivity of 1 ng/ml in milk and in the cheese extract or 1.3 ng/ml in the chicken salad extract.  相似文献   

4.
Detection of T-2 toxin by an improved radioimmunoassay.   总被引:8,自引:8,他引:0       下载免费PDF全文
T-2 toxin in serum, urine, and saline was analyzed by a modified radioimmunoassay procedure. The specimens were added directly to the assay tubes without extraction steps. The reaction between antibody and ligands was optimal at 1 h. Albumin-coated charcoal was used to separate bound from free radioactivity. Quenching, which occurred with hemolyzed specimens, was corrected by a wet oxidation process with 60% perchloric acid and 30% hydrogen peroxide. The shorter incubation times resulted in an assay that takes less than 6 h to complete. The average affinity constant of the antibody (Km) was 1.75 X 10(10) liters/mol. The sensitivity was 1 ng per assay or 10 ng/ml. Among the other trichothecenes tested, only H-T-2 cross-reacted significantly (10.3%).  相似文献   

5.
T-2 toxin in serum, urine, and saline was analyzed by a modified radioimmunoassay procedure. The specimens were added directly to the assay tubes without extraction steps. The reaction between antibody and ligands was optimal at 1 h. Albumin-coated charcoal was used to separate bound from free radioactivity. Quenching, which occurred with hemolyzed specimens, was corrected by a wet oxidation process with 60% perchloric acid and 30% hydrogen peroxide. The shorter incubation times resulted in an assay that takes less than 6 h to complete. The average affinity constant of the antibody (Km) was 1.75 X 10(10) liters/mol. The sensitivity was 1 ng per assay or 10 ng/ml. Among the other trichothecenes tested, only H-T-2 cross-reacted significantly (10.3%).  相似文献   

6.
Parameters and conditions of an enzyme based assay for biotin and avidin are presented. Biotinylated glucose-6-phosphate dehydrogenase when complexed with avidin becomes inactivated. Thus it was possible to construct a competitive assay system for biotin. The assay is sensitive between 100-500 ng/ml and could detect as little as 10 ng in 0.1 ml with a between run error of 2.4%. It requires a 60 min incubation at 21 degrees C and 5 min to assay. The avidin assay, based on the degree of inactivation of biotinylated-glucose-6-phosphate dehydrogenase in relation to the concentration of avidin, could detect as little as 0.25 ng in 0.1 ml or 2.5 ng/ml with an assay time of 10 min with a between run error of 3.9%. Both assays are rapid with significant improvements over other non-isotopic methods in sensitivity and comparable to radioisotopic methods in sensitivity with the added advantage of ease of method.  相似文献   

7.
The development of the HIV protease inhibitor saquinavir (Ro 31-8959) required a range of analytical methods for its measurement in biological fluids. This paper describes the development of isocratic, reverse-phase HPLC/UV methods for the routine measurement of plasma levels of the drug together with a more sensitive radioimmunoassay. The performance of the two assays is compared with that of an HPLC/MS/MS method previously published and has been shown to be satisfactory, with coefficients of variation of calibration standards and quality control samples within the usual outside limits of +/- 15%. The HPLC/UV method can be routinely applied for concentrations down to 10-20 ng/ml and a lower limit of quantification of 1 ng/ml from 1 ml of human plasma is possible. The radioimmunoassay was developed for the specific measurement of saquinavir concentrations in human, HIV-positive plasma samples and has a lower limit of quantification of 0.5-1.0 ng/ml. Some preliminary findings suggested that it might not be specific in rat plasma and no attempts have been made to quantify any nonclinical samples with this technique. If still greater sensitivity is required, recourse can be made to the HPLC/MS/MS assay.  相似文献   

8.
Bisantrene and mitoxantrone are two new anthracene derivatives which have shown significant antitumor activity against a wide variety of animal tumors and in human phase I and II clinical trials. We have developed a rapid, simple and sensitive sample cleanup procedure and high-performance liquid chromatographic (HPLC) assay for both drugs. This method uses a commercially available mini-cartridge with C18 reversed-phase packing to isolate the drugs from the biological matrix prior to HPLC. For both drugs the average recovery of the assay was 98 ± 6% with a coefficient of variation (C.V.) of less than 7%. Using this new method our assay sensitivity has improved to less than 10 ng/ml for bisantrene and 1 ng/ml for mitoxantrone, allowing us to document a prologned terminal phase plasma half-life for both bisantrene and mitoxantrone. Equilibrium dialysis studies showed that both drugs are highly protein bound. Mitoxantrone appears less stable in human plasma than bisantrene. Recoveries from plasma after a 24-h incubation at 25 and 37°C were 40 and 20% for mitoxantrone and 90 and 85% for bisantrene, respectively. Addition of ascorbic acid prior to incubation of mitoxantrone in human plasma at 37°C resulted in less than a 10% decrease in the latter's concentration over a 24-h period. To maintain sample integrity, all plasma samples should be fortified with ascorbic acid and kept frozen prior to analyses.  相似文献   

9.
A sensitive and selective high-performance liquid chromatographic method was developed for the determination of itraconazole and its active metabolite, hydroxyitraconazole, in human plasma. Prior to analysis, both compounds together with the internal standard were extracted from alkalinized plasma samples using a 3:2 (v/v) mixture of 2,2,4-trimethylpentane and dichloromethane. The mobile phase comprised 0.02 M potassium dihydrogen phosphate-acetonitrile (1:1, v/v) adjusted to pH 3.0. Analysis was run at flow-rate of 0.9 ml/min with excitation and emission wavelengths set at 260 and 365 nm, respectively. Itraconazole was found to adsorb on glass or plastic tubes, but could be circumvented by prior treating the tubes using 10% dichlorodimethylsilane in toluene. Moreover, rinsing the injector port with acetonitrile helped to overcome any carry-over effect. This problem was not encountered with hydroxyitraconazole. The method was sensitive with limit of quantification of 3 ng/ml for itraconazole and 6 ng/ml for hydroxyitraconazole. The calibration curve was linear over a concentration range of 2.8-720 ng/ml for itraconazole and 5.6-720 ng/ml for the hydroxy metabolite. Mean recovery value of the extraction procedure for both compounds was about 85%, while the within-day and between-day coefficient of variation and percent error values of the assay method were all less than 15%. Hence, the method is suitable for use in pharmacokinetic and bioavailability studies of itraconazole.  相似文献   

10.
A sensitive, specific and stability-indicating high-performance liquid chromatographic (HPLC) assay, involving pre-column derivatization and solid-phase extraction (SPE), was developed and validated for the quantitation of busulfan (BU) in aqueous and plasma samples. The linearity of the assay was in the concentration ranges of 0.15–10 μg/ml and 0.15–3 μg/ml for aqueous and plasma samples, respectively. The within-day and between-day variations were 2.90 and 3.31%, respectively, for the aqueous samples, and 9.24 and 14.56%, respectively, for the plasma samples. The overall recovery, derivatization yield and SPE efficiency of BU from plasma samples were 82.03, 108.01 and 86.69%, respectively. Forced degraded samples, either in highly acidic, neutral or basic medium, produced no interfering peaks in the chromatogram. The reported assay requires only 0.2 ml of plasma for the analysis, and its sensitivity is 150 ng/ml by monitoring samples at a wavelength of 254 nm, sufficient to study the plasma pharmacokinetics of BU in rats after a clinically relevant oral dose. Moreover, the sensitivity of the assay can be significantly increased to 30 ng/ml by monitoring samples at a wavelength of 278 nm. The applications of the assay were demonstrated with BU solubility measurements in two aqueous systems and with plasma samples from a Sprague–Dawley rat for an in vivo pharmacokinetic study. In addition, the assay has been employed in the development of a patented intravenous formulation, and in evaluations of stability, preclinical pharmacokinetics in rats and dogs, and clinical phase I trial of the formulation. The assay is readily adaptable to clinical therapeutic drug monitoring.  相似文献   

11.
A sensitive plasma assay for acyclovir has been developed and validated. Acyclovir was separated from plasma components using Oasis HLB columns. Separation was obtained with no plasma interference using micellar electrokinetic chromatography (175 mM SDS) and hydroxypropyl-beta-cyclodextrin (100 mM) in 90 mM borate buffer (pH 8.8) containing 0.2% NaCl. High sensitivity was achieved by large volume sample introduction and stacking. The linear range was from 20 to 10000 ng/ml with a limit of quantitation of 20 ng/ml. This method is a viable alternative to HPLC because of its high separation and sensitivity, reproducibility, and adaptability to other nucleoside analogs.  相似文献   

12.
An indirect competitive enzyme-linked immunosorbent assay (ELISA) was developed using rabbit polyclonal antibodies against the eremomycin-glucose oxidase conjugated antigen. This technique allows the glycopeptide antibiotic eremomycin to be determined both in aqueous solutions (with a sensitivity as high as 0.1 ng/ml) and in blood plasma. The cross-reactivity of the antibodies with vancomycin was 0.4% of that for eremomycin, while teicoplanin was almost not recognized. Experiments with blood plasma samples diluted 1: 10 showed that the assay was linear over the concentration range 1–30 ng/ml and that the variation coefficient did not exceed 10%. The high sensitivity and selectivity of this test make it suitable for pharmacokinetic studies and drug monitoring analysis.  相似文献   

13.
Reddy DS  Venkatarangan L  Chien B  Ramu K 《Steroids》2005,70(13):879-885
The testosterone metabolite 3alpha-androstanediol (5alpha-androstane-3alpha,17-diol) is a potential GABA(A) receptor-modulating neurosteroid with anticonvulsant properties and hence could act as a key neuromodulator in the central nervous system. However, there is no specific and sensitive assay for quantitative determination of the androgenic neurosteroid 3alpha-androstanediol in biological samples. We have established a liquid chromatography-tandem mass spectrometry (LC-MS-MS) assay to measure 3alpha-androstanediol in rat plasma. Standard 3alpha-androstanediol added to rat plasma has been successfully analysed with excellent linearity, specificity, sensitivity, and reproducibility. The sensitivity of the method was < 10 ng/ml with a detection limit of 2 ng/ml (6.8 nmol/l) and a linear range of 10-2000 ng/ml. The method was used for the analysis of testosterone-induced increase in plasma 3alpha-androstanediol levels in rats. Testosterone produced a dose-dependent elevation in plasma 3alpha-androstanediol, which was almost completely prevented by pretreatment with the 5alpha-reductase inhibitor finasteride, indicating that 3alpha-androstanediol is synthesized from testosterone via a 5alpha-reductase pathway. This LC-MS-MS method allows accurate, high-throughput analysis of 3alpha-androstanediol in small amounts (200 microl) of plasma and possibly other biological samples.  相似文献   

14.
The methodical bases for detecting antibiotics using a bioluminescent assay and blood serum are briefed. Antibiotics inhibit the luminescence of a genetically engineered Escherichia coli strain. The degree of inhibition depended on the type of antibiotic, its concentration, and the time of cell incubation with antibiotic. The highest cell sensitivity was recorded towards the aminoglycoside antibiotics, which amounted to 85 +/- 10 ng/ml for gentamicin and streptomycin. The sensitivity of this system to a number of antibiotics essentially increased when the cells were previously activated with blood serum. The sensitivity of this method for gentamicin and streptomycin in the presence of blood serum amounted to 2.5 +/- 0.5 ng/ml; for tetracycline, 45 +/- 8 ng/ml. Use of the sera containing specific antibodies to the antibiotic detected provided a high sensitivity of the biosensor tested. Comparison of the luminescences of E. coli cells activated with normal and specific antisera upon incubation with an antibiotic allows the type of antibiotic and its quantitative content in the sample to be determined. Characteristic of the analysis of antibiotics with the help of recombinant E. coli are a high accuracy, sensitivity, specificity, simplicity, and a short time needed for measurement.  相似文献   

15.
The platelet-derived growth factor (PDGF) is the principal mitogen in serum for cultured cells of mesenchymal origin. PDGF also is a potent chemotactic protein for inflammatory cells and for cells required for wound repair. Because activity levels of PDGF in biological fluids are difficult to measure, we attempted to develop a radioimmunoassay for PDGF. Rabbits were immunized with purified PDGF; the antiserum obtained was monospecific for PDGF in immunodiffusion analysis against concentrated platelet lysates, serum, and plasma. A radioimmunoassay for PDGF was developed with a sensitivity of congruent to 0.2 ng/ml. Levels of PDGF in plasma/serum were measured and compared with PDGF levels determined by a receptor-competition assay and by a standard biological assay measuring incorporation of [3H]thymidine into 3T3 cells. Radioimmunoassay showed apparent PDGF levels of 50 ng/ml in human plasma and 103 ng/ml in serum. The 50 ng/ml PDGF in plasma was unexpected because the plasma samples contained little or no platelet release products as determined by very low levels of platelet factor 4. We therefore sought an immunologically reactive PDGF molecule in human plasma. No immunologically reactive protein was detected by immunodiffusion analysis or when plasma was treated with an immunoaffinity gel. Subsequently, a 125I-PDGF-binding protein was identified; the 125I-PDGF-plasma-binding protein complex was not reactive with anti-PDGF immunoglobulin. Correction for 125I-PDGF bound by the plasma-binding protein established serum levels of PDGF of congruent to 50 ng/ml; congruent to 50 ng/ml PDGF was found in serum by radioreceptor-competition assays and by mitogenic assays as well. The plasma-binding protein may serve to clear PDGF released in the circulation, thereby limiting PDGF activity to its local interactions at the site of blood-vessel injury.  相似文献   

16.
The gelation of standard Limulus amoebocyte lysate (LAL) is triggered by the addition of a small amount of beta-glucan (1-1000 ng/ml plasma), but in the presence of an excessive amount of beta-glucan (1 mg/ml plasma), the gelation becomes insensitive to beta-glucan. Utilizing this property, a method to determine quantitatively the amount of endotoxin circulating in humans was developed. When a modified LAL, or LAL-ES, which contains an excessive amount of CM-curdlan as beta-glucan, was used for the assay, a linear relation in the logarithmic scales was obtained between the gelation time measured by the turbidimetry (min) and the concentration of endotoxin. This relation was not affected by a considerable amount of beta-glucan (100 ng/ml). The sensitivity of the endotoxin assay was estimated to be as low as 3 pg/ml. The following aspects of the method were found by clinical application to normal and febrile subjects. (1) Using both LAL and LAL-ES, it was possible to distinguish the effect of endotoxin from that of beta-glucan in plasma, i.e., bacterial sepsis from fungal sepsis. (2) The amount of circulating endotoxin determined by the present method showed good correlation to those obtained by chromogenic assay using modified LAL devoid of Factor G which could be activated by beta-glucan.  相似文献   

17.
A fluorescence-based continuous-flow immunosensor for sensitive, precise, accurate and fast determination of paclitaxel was developed. The sensor utilizes anti-paclitaxel antibody immobilized through its Fc region and crosslinked by dimethylpimelimidate to protein A attached covalently onto the silanized inner walls of a glass capillary column followed by saturation of the paclitaxel-binding sites with rhodamine-labeled paclitaxel. The assay is based on the displacement and detection downstream of the rhodamine-labeled paclitaxel, by a flow-through spectrofluorometer, as a result of the competition with paclitaxel introduced as a pulse into the stream of carrier buffer flowing through the system. The peak height of the fluorescence intensity profile of the displaced rhodamine-labeled paclitaxel was directly proportional to the concentration of paclitaxel applied and was a function of the carrier buffer flow rate. The sensitivity of the immunosensor response ranged from 0.31 relative fluorescence units (RFU)/ng/ml at a flow rate 0.1 ml/min to 0.52 RFU/ng/ml at 1 ml/min, while the lower detection limit ranged from 1 ng/ml at 0.1 ml/min to 4 ng/ml at 1 ml/min. The immunosensor response was very reproducible (RSD=4.8%; n=10) and linear up to 100 ng/ml. The assay time ranged from 2 min at 1 ml/min to 8 min at 0.1 ml/min. A technique developed to resaturate the antigen binding sites of the immobilized antibody with rhodamine-labeled paclitaxel was successful in regenerating the capillary column without affecting its performance, thus enhancing the economic viability of the immunosensor. The immunosensor was successfully applied for the determination of paclitaxel in human plasma.  相似文献   

18.
A simple, sensitive and reproducible high-performance liquid chromatography (HPLC) method was developed for the determination of terazosin in human plasma. The method involves a one-step single solvent extraction procedure using dichloromethane with a 0.25 ml plasma sample. Recovery values were all greater than 90% over the concentration range 0.25–100 ng/ml. Terazosin was found to adsorb to glass or plastic tubes, but this could be circumvented by using disposable plastic tubes. Also, rinsing the injector port with methanol after each injection helped to prevent any carry-over effect. The internal standard, prazosin, did not exhibit this problem. The method has a quantification limit of 0.25 ng/ml. The within- and between-day coefficient of variation and accuracy values were all less than 7% over the concentration range 0.25–100 ng/ml and hence the method is suitable for use in pharmacokinetic studies of terazosin.  相似文献   

19.
The subcommissural organ (SCO) is an ependymal brain gland that releases glycoproteins into the ventricular cerebrospinal fluid where they condense to form the Reissner’s fiber (RF). We have developed a highly sensitive and specific two-antibody sandwich enzyme-linked immunosorbent assay (ELISA) for the quantification of the bovine SCO secretory material. The assay was based on the use of the IgG fraction of a polyclonal antiserum against the bovine RF as capture antibody and a pool of three peroxidase-labeled monoclonal antibodies that recognize non-overlapping epitopes of the RF glycoproteins as detection antibody. The detection limit was 1 ng/ml and the working range extended from 1 to 4000 ng/ml. The calibration curve, generated with RF glycoproteins, showed two linear segments: one of low sensitivity, ranging from 1 to 125 ng/ml, and the other of high sensitivity between 125 and 4000 ng/ml. This assay was highly reproducible (mean intra- and interassay coefficient of variation 2.2% and 5.3%, respectively) and its detectability and sensitivity were higher than those of ELISAs using exclusively either polyclonal or monoclonal antibodies against RF glycoproteins. The assay succeeded in detecting and measuring secretory material in crude extracts of bovine SCO, culture medium supernatant of SCO explants and incubation medium of bovine RF; however, soluble secretory material was not detected in bovine cerebrospinal fluid.  相似文献   

20.
A relatively simple assay with improved reliability and sensitivity for measuring levels of 6-mercaptopurine in human plasma is presented. After extraction of the compound and the added internal standard with phenyl mercury acetate, samples were separated by ion-pair reversed-phase high-performance liquid chromatography. On-line the analytes were oxidized to fluorescent products and detected in a flow-fluorimeter. The within-day coefficient of variation was 3.8% at a concentration of 25 ng/ml. The lower detection limit was 2 ng/ml when 1.0 ml of plasma was used. Mercaptopurine concentration versus time curves of two subjects after a single oral dose of azathioprine are shown.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号