首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
We have previously reported that exposing the vegetative plasmodia stage of Physarum polycephalum to either individual or simultaneously applied electric and magnetic fields (45-75 Hz, 0.14-2.0 G, and 0.035-0.7 V/m) lengthens their mitotic cycle, depresses their rate of reversible shuttle streaming, and lowers their respiration rate. In this article we report the effects of simultaneously applied electromagnetic fields (60 Hz, 1.0 G, 1.0 V/m), electric fields only (60 Hz, 1.0 V/m), magnetic fields only (60 Hz, 1.0 G) on the haploid amoeba of Physarum exposed for 120-180 days. Statistically significant depressions (about 8-11%) in ATP levels were observed with all field conditions; however, respiration was significantly decreased only when amoebae were subjected to either combined fields or electric fields alone. Magnetic fields alone failed to induce a significant decrease in respiration.  相似文献   

2.
Extremely low frequency magnetic fields interact with an animal by inducing internal electric fields, which are in addition to the normal endogenous fields present in living animals. Male rats weighing about 560 g each were anesthetized with ketamine and xylazine. Small incisions were made in the ventral body wall at the chest and upper abdomen to position a miniature probe for measuring internal electric fields. The calibration constant for the probe size was 5.7 mm, with a flat response from at least 12 Hz to 20 kHz. A cardiac signal, similar to the normal electrocardiogram with a heart rate of about 250 bpm, was readily obtained at the chest. Upon analysis of its spectrum, the cardiac field detected by the probe had a broad maximum at 32–95 Hz. When the rats were exposed to a 1 mT, 60 Hz magnetic field, a spike appeared in the spectrum at 60 Hz. The peak-to-peak magnitudes of electric fields associated with normal heart function were comparable to fields induced by a 1 mT magnetic field at 60 Hz for those positions measured on the body surface (where induced fields were maximal). Within the body, or in different directions relative to the applied field, the induced fields were reduced (reaching zero at the center of the animal). The cardiac field increased near the heart, becoming much larger than the induced field. Thus, the cardiac electric field, together with the other endogenous fields, combine with induced electric fields and help to provide reference levels for the induced-field dosimetry of ELF magnetic field exposures of living animals. Bioelectromagnetics 18:317–323, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

3.
Myelogenous leukemia and electric blanket use   总被引:2,自引:0,他引:2  
In a case-control study of adult acute and chronic myelogenous leukemia in Los Angeles County, we tested the hypothesis that excess exposure to electromagnetic fields from electric blankets was associated with risk of leukemia. We did this by studying 116 cases of acute myelogenous leukemia (AML) and 108 cases of chronic myelogenous leukemia (CML) along with matched neighborhood controls. The cases and controls were queried as to electric blanket use and the risks computed. For AML the risk was 0.9 (95% CI 0.5-1.6) and for CML the risk was 0.8 (95% CI 0.4-1.6). Cases did not differ from controls by duration of use, year of first regular use, year since last use, or socioeconomic status. Our best estimates of exposure indicate that electric blanket use increases overall exposure to electric fields by less than 50% and magnetic fields by less than 100%. We conclude that there is no major leukemogenic risk associated with electric blanket use in Los Angeles County.  相似文献   

4.
Pregnant CD1 mice were exposed or sham-exposed from day 0 to day 17 of gestation to a 50 Hz sinusoidal magnetic field at 20 mT (rms). Preimplantation and postimplantation survival were assessed and fetuses examined for the presence of gross external, internal, and skeletal abnormalities. There were no statistically significant field-dependent effects on preimplantation or postimplantation survival, sex ratio, or the incidence of fetuses with internal or skeletal abnormalities. Magnetic field exposure was, however, associated with longer and heavier fetuses at term, with fewer external abnormalities. The results lend no support to suggestions of increased rates of spontaneous abortion or congenital malformation following prenatal exposure to power frequency magnetic fields. © 1994 Wiley-Liss, Inc.  相似文献   

5.
Exposure systems that provide good magnetic field uniformity, minimum stray fields, and minimal heating, vibration, and hum, as well as capability for true sham exposure in which current flows in the coils, are needed to determine rigorously the biological effects of weak magnetic fields. Designs based on acrylic polymer coil support structures and twisted pair bifilary coil windings were employed to fabricate several different systems for the exposure of laboratory animals and cell cultures to magnetic fields. These systems exhibit excellent performance characteristics in terms of exposure field uniformity, stray field containment, and exposure field cancellation in the sham exposure mode. A custom-written computer program was used to determine the best arrangement for coils with regard to field uniformity in the exposure volume and stray field containment. For in vivo exposures, modules were made up of four Merritt four-coil sets, built into a single structure and positioned to form an octapole with fields directed in the horizontal plane. For in vitro applications, two different coil configurations were selected to produce the vertical fields required. A quadrupole system, comprising modules consisting of two Merritt four-coil sets arranged side by side to limit stray fields, was built as a prototype. In the second configuration, one Merritt four-coil set was positioned inside the other to form a concentric coil set. In both in vitro systems, exposure chambers were connected to remote commercial incubators in order to reduce ambient magnetic fields in the exposure volume. An active field cancellation circuit was developed for reducing ambient AC magnetic fields in the in vitro sham exposure chamber, when necessary. These design and fabrication approaches provide systems that offer uniform field exposures and excellent stray field containment when needed and are portable, washable, and relatively inexpensive. © 1994 Wiley-Liss, Inc.
  • 1 This article is a US Government work and, as such, is in the public domain in the United States of America.
  •   相似文献   

    6.
    Recent laboratory and epidemiological results have stimulated interest in the hypothesis that human beings may exhibit biological responses to magnetic and/or electric field transients with frequencies in the range between 100 Hz and 100 kHz. Much can be learned about the response of a system to a transient stimulation by understanding its response to sinusoidal disturbances over the entire frequency range of interest. Thus, the main effort of this paper was to compare the strengths of the electric fields induced in homogeneous ellipsoidal models by uniform 100 Hz through 100 kHz electric and magnetic fields. Over this frequency range, external electric fields of about 25–2000 V/m (depending primarily on the orientation of the body relative to the field) are required to induce electric fields inside models of adults and children that are similar in strength to those induced by an external 1 μT magnetic field. Additional analysis indicates that electric fields induced by uniform external electric and magnetic fields and by the nonuniform electric and magnetic fields produced by idealized point sources will not differ by more than a factor of two until the sources are brought close to the body. Published data on electric and magnetic field transients in residential environments indicate that, for most field orientations, the magnetic component will induce stronger electric fields inside adults and children than the electric component. This conclusion is also true for the currents induced in humans by typical levels of 60 Hz electric and magnetic fields in U.S. residences. Bioelectromagnetics 18:67–76, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

    7.
    The three‐dimensional distribution of the specific absorption rate of energy (SAR) in phantom models was analysed to detect clusters of mobile phones producing similar spatial deposition of energy in the head. The clusters' characteristics were described from the phones external features, frequency band and communication protocol. Compliance measurements with phones in cheek and tilt positions, and on the left and right side of a physical phantom were used. Phones used the Personal Digital Cellular (PDC), Code division multiple access One (CdmaOne), Global System for Mobile Communications (GSM) and Nordic Mobile Telephony (NMT) communication systems, in the 800, 900, 1500 and 1800 MHz bands. Each phone's measurements were summarised by the half‐ellipsoid in which the SAR values were above half the maximum value. Cluster analysis used the Partitioning Around Medoids algorithm. The dissimilarity measure was based on the overlap of the ellipsoids, and the Manhattan distance was used for robustness analysis. Within the 800 MHz frequency band, and in part within the 900 MHz and the 1800 MHz frequency bands, weak clustering was obtained for the handset shape (bar phone, flip with top and flip with central antennas), but only in specific positions (tilt or cheek). On measurements of 120 phones, the three‐dimensional distribution of SAR in phantom models did not appear to be related to particular external phone characteristics or measurement characteristics, which could be used for refining the assessment of exposure to radiofrequency energy within the brain in epidemiological studies such as the Interphone. Bioelectromagnetics. Bioelectromagnetics 32:634–643, 2011. © 2011 Wiley Periodicals, Inc.  相似文献   

    8.
    The effects of exposure to static (1–100 mT) or sinusoidal (1 Hz, 1.6 mT) magnetic fields on the production of nitric oxide (NO) by murine BCG-activated macrophages were investigated. In these cells, the inducible isoform of NO synthase is present. No significant differences were observed in nitrite levels among exposed, sham-exposed, or control macrophages after exposure for 14 h to static fields of 1, 10, 50, and 100 mT and to sinusoidal 1.6 mT, 1 Hz magnetic fields. © 1996 Wiley-Liss, Inc.  相似文献   

    9.
    目的:以永磁体构建静磁柱体内植入物,应用Micro-CT技术,探索研究内植静磁柱联合脉冲电磁场对骨组织的修复作用。方法:选取新西兰兔24只建立右侧股骨髁骨缺损模型,并随机分为联合磁场组,脉冲电磁场组和对照组。联合磁场组自兔右侧股骨干远端向髓内植入静磁柱,并联合施加体外脉冲电磁场(1 h/d);脉冲电磁场组及对照组均将无磁性钛合金棒植入右侧股骨干髓腔,同时,脉冲电磁场组于体外加载脉冲电磁场(1 h/d)。术后5周处死取材,应用Micro-CT对股骨远端样本进行扫描检测,并对骨缺损区域显微结构进行三维重建分析。结果:与非磁场组相比,联合磁场组骨缺损区域骨小梁相对体积及数目明显增加(P均0.05),骨小梁分离度下降(P0.01)。与传统脉冲电磁场组相比,联合磁场组骨小梁数目增加(P0.05),骨小梁分离度下降(P0.01)。扫描及重建图像可见,联合磁场组骨缺损区域骨量增多,外侧皮质区愈合完整,骨小梁结构连续致密,具有更好的骨显微结构。结论:内植静磁柱与脉冲电磁场的联合磁场干预方式能够在早期获得更好的成骨修复能力,为磁场治疗相关骨病的临床及基础研究提供了新的方向。  相似文献   

    10.
    A controlled pilot study was performed to examine the possibility of finding a specific electromagnetic field signal to inhibit angiogenesis during tumor growth. A 120 Hz pulsating magnetic field of 4 and 5 mT was applied to female mice which had been inoculated with murine 16/C mammary adenocarcinoma. After 11 consecutive sessions of 10 min/day exposure to the magnetic field, the animals were sacrificed and an immunohistochemistry analysis of the tumors was performed. CD31 staining indicated that both magnetic fields significantly reduced the vasculature in the tumors: 39% at 4 mT magnetic flux density and 53% at 5 mT. The positive implications for impeding tumor growth and metastasis warrant further studies.  相似文献   

    11.
    12.
    We consider the possibility that DC magnetic fields can interact in a resonant manner with endogenous AC electric fields in biological systems. Intrinsic electric-field ion cyclotron resonance (ICR) interactions would be more physically credible than models based on external AC magnetic fields and might be expected as an evolutionary response to the long-term constancy of the geomagnetic field. Bioelectromagnetics 17:85–87, 1997. © 1997 Wiley-Liss, Inc.  相似文献   

    13.
    Potential effects of extremely low frequency (ELF) electromagnetic fields on periphyton were studied from 1983 to 1993 using a Before, After, Control and Impact design. The study was conducted at two sites on the Ford River, a fourth-order brown water trout stream in Dickinson County, Michigan. The Reference site received 4.9–6.5 times less exposure to ground electric fields and from 300 to 334 times less exposure to magnetic flux from 1989 to 1993 when the antenna was operational at 76 Hz than did the Antenna site. The objective of the study was to determine if ELF electromagnetic fields had caused changes in structure and/or function of algal communities in the Ford River. Significant differences in chlorophyll a standing crop and daily accumulation rate (a surrogate for primary productivity), and organic matter standing crop and daily accumulation rate were observed between the Reference and Antenna site after the antenna became operational. These four related community function variables all increased at the Antenna site with largest and most consistent increases occurring for chlorophyll measures. Compared to pre-operational data, the increase in chlorophyll at the Antenna site also occurred during a period of low amperage testing in 1986–1988, and did not increase further when the antenna became fully operational in 1989, indicating a low threshold for response. There was no significant differences between the Antenna and Reference sites in community structure variables such as diversity, evenness and the relative abundance of dominant diatoms. Thus, 76 Hz ELF electromagnetic radiation apparently did not change the basic makeup of the diatom community but did increase accumulation rates and standing crops of chlorophyll a and organic matter.  相似文献   

    14.
    Several authors have concluded that thermal electromagnetic noise will be of sufficient magnitude to overwhelm electric and/or magnetic fields induced by environmentally generated, power frequency electric and magnetic fields in the membranes of living cells located in the bodies of humans. Yet, there are research reports that indicate that living cells may respond to power frequency electric and/or magnetic field levels well below the limits set by these thermal noise arguments. The purpose of this study is to suggest that published thermal arguments may not make a full accounting of all membrane force fields of thermal origin, and that when such an accounting is made, the net thermal noise fields may be smaller in the power frequency range than previously thought. If this analysis is correct, there may be no thermal noise barrier that precludes the possibility of cellular membranes of human cells responding to environmental levels of power frequency electric or magnetic fields.  相似文献   

    15.
    16.
    Rats with skin-wounds surgically created on their backs were exposed immediately after surgery and every 12 h thereafter to pulsed, extremely-low-frequency magnetic fields. The shape of the pulse was a positive triangle (50 Hz, 8 mT peak). The rate of healing of skin wounds was evaluated macroscopically and by light and electron microscopy at 6, 12, 21, and 42 days after the operation. A significant increase in the rate of wound contraction was found in rats treated with magnetic fields. Forty-two days after surgery all treated animals show fully closed wounds, while control rats at the same time intervals still lacked a final 6% of the wound surface to be covered. Treated rats showed earlier cellular organization, collagen formation and maturation, and a very early appearance of newly formed vascular network.  相似文献   

    17.
    Effects of alternating magnetic fields (MFs) on the embryonic and fetal development in CBA/Ca mice were studied. Mated females were exposed continuously to a sinusoidal 50 Hz (13 μT or 0.13 mT root mean square) or a sawtooth 20 kHz (15 μT peak-to-peak) MF from day 0 to day 18 of pregnancy for 24 h/day until necropsied on day 18. Control animals were kept under the same conditions without the MF. MFs did not cause maternal toxicity. No adverse effects were seen in maternal hematology and the frequency of micronuclei in maternal bone marrow erythrocytes did not change. The MFs did not increase the number of resorptions or fetuses with major or minor malformations in any exposure group. The mean number of implantations and living fetuses per litter were similar in all groups. The corrected weight gain (weight gain without uterine content) of dams, pregnancy rates, incidences of resorptions and late fetal deaths, and fetal body weights were similar in all groups. There was, however, a statistically significant increase in the incidence of fetuses with at least three skeletal variations in all groups exposed to MFs. In conclusion, the 50 Hz or 20 kHz MFs did not increase incidences of malformations or resorptions in CBA/Ca mice, but increased skeletal variations consistently in all exposure groups. Bioelectromagnetics 19:477–485, 1998. © 1998 Wiley-Liss, Inc.  相似文献   

    18.
    19.
    In vitro assays were made of the effect of a static magnetic field of a neodymium magnet on cellular behavior. The cell turnover rate was examined by the incorporation of radioactive thymidine, and anabolic processes were measured by the incorporation of radioactive proline. Cell cultures of fibroblast- and osteoblast-like cells of the neonatal rat calvarium were assayed to determine uptakes of radioactive thymidine and proline; these assays were performed in conjunction with examination of an explant of the rat calvarium. The cells were assayed after exposure to a field for 1-, 3-, 5-, 7-, and 10-day periods. Cells were exposed to north and south poles with a pole-face flux density of 0.61 T; control cultures were exposed to an unmagnetised piece of neodymium. After sham exposure or exposure to the magnetic field, 50 μCuries/ml of culture media of isotope were added to the culture medium. The cultures were returned to an incubator for 6 h. Then, following centrifugation, the supernatant was assayed for radioactivity in a scintillation counter after addition of 3 ml of scintillation fluid. A statistically significant magnetic stimulation of turnover rate and synthesis of fibroblasts was found, but stimulation of osteoblasts did not occur. Conversely, the explants, which represent the osteoblasts and fibroblasts in an organised system, showed a statistically significant inhibition in uptake of the radioactive label. The data indicate both variability and diversity of cellular behaviour, and they accentuate the need for caution in the interpretation of effects of static magnetic fields. © 1993 Wiley-Liss, Inc.  相似文献   

    20.
    The purpose of this in vitro study was to assess the potential influence of low frequency, low intensity magnetic fields (rectangular pulse, 5 mT, 30 Hz) applied in therapy on the temperature, contact electric potential, and magnetization in knee endoprosthesis, which might be dangerous for implantation and stability of knee prosthesis, and later slacking it off, causing postoperative complications. The experimental investigation was carried out on a knee endoprosthesis which had been placed in a container with physiological saline. The prosthesis located inside the container was under the exposure of the magnetic field applied by a solenoid. The results indicated that magnetic fields did not influence thermal and electromagnetic properties of knee endoprosthesis in vitro. The magnetic fields of examined parameters should not be dangerous for implantation and stability of knee endoprosthesis. Bioelectromagnetics 30:159–162, 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

    设为首页 | 免责声明 | 关于勤云 | 加入收藏

    Copyright©北京勤云科技发展有限公司  京ICP备09084417号