1.
The recent emphasis on gloving has resulted in accounts of healthcare workers washing gloves instead of changing them. This study evaluated the efficacy of soap and three germicidal agents in decontaminating latex and vinyl medical gloves that were experimentally contaminated with Staphylococcus aureus. Gloves were tested for perforations before and after the glovewashing procedure. Results of this study demonstrated that contamination was reduced from the glove surfaces. Although the routine washing of gloved hands cannot be recommended, it may be carried out under limited circumstances.  相似文献   

2.
The purpose of this study was to ascertain whether viable bacteria could be transferred from gloves to laboratory cards in dental records and, if so, to determine whether bacteria could survive on the paper. The thumbs and forefingers of two types of glove (Biogel D and Microtouch) were inoculated with Streptococcus sanguis and left for various periods of time. A sterile dental laboratory card was then held with the gloves and the number of bacteria surviving on the card determined after various periods of incubation of the card at room temperature. Bacteria were transferred to the laboratory cards and remained viable for up to 72 h. More viable bacteria were transferred from the Microtouch gloves than from the Biogel D gloves, and this was attributable, in part, to the latter gloves exerting a bactericidal effect. The results demonstrated that bacteria can be transferred from gloves to laboratory cards and that these organisms can remain viable for long periods of time. Dental records may, therefore, represent a possible route of cross-infection.  相似文献   

3.
The objective of this study was to explore the utility of nitrile gloves as a replacement for latex surgical gloves in recovering bacteria from the hands. Two types of nitrile gloves were compared to latex gloves using the parallel streak method. Streaks of Klebsiella pneumoniae and Staphylococcus aureus were made on tryptic soy agar plates, and the zones of inhibition were measured around pieces of glove material placed on the plates. Latex gloves produced a mean zone of inhibition of 0.28 mm, compared to 0.002 mm for nitrile gloves (p<.001). While the parallel streak method is not intended as a quantitative estimate of antimicrobial properties, these results suggest that nitrile may be a viable alternative to latex in glove juice sampling methods, since nitrile avoids the risk of latex exposure.  相似文献   

4.
The purpose of this procedure is to infect the Aedes mosquito with dengue virus in a laboratory condition and examine the infection level and dynamic of the virus in the mosquito tissues. This protocol is routinely used for studying mosquito-virus interactions, especially for identification of novel host factors that are able to determine vector competence. The entire experiment must be conducted in a BSL2 laboratory. Similar to Plasmodium falciparum infections, proper attire including gloves and lab coat must be worn at all times. After the experiment, all the materials that came in contact with the virus need to be treated with 75% ethanol and bleached before proceeding with normal washing. All other materials need to be autoclaved before discarding them.  相似文献   

5.
Contamination in a trace element laboratory can come from a variety of sources, including laboratory gloves. Therefore, vinyl and latex gloves were obtained from as many manufacturers as would supply gloves. These gloves were either prepared for acid-washing and subsequent soaking in an acid solution, or immersed in an acid solution for a duration of either 1 min or 1 h. Incubation washes were analyzed for a variety of trace elements by flame atomic abosrption spectroscopy (AAS) or inductively coupled mass spectrometry (ICP-MS). Results indicated that only three brands of vinyl gloves were acceptable for use in a trace element laboratory, whereas others had contamination of different elements. Latex gloves contained such high levels of biologically important elements that they were not considered suitable for routine trace element work. Vinyl gloves of choice should be routinely acid-washed before use in a trace element laboratory.  相似文献   

6.
Virus penetration of examination gloves   总被引:3,自引:0,他引:3  
Examination gloves worn for protection from biohazards were sampled and evaluated for their ability to exclude virus particles. We found that thin gloves manufactured from polyethylene or polyvinyl chloride are ineffective barriers while gloves of thin latex are superior but not without failure. Polyethylene and polyvinyl chloride gloves had failure rates of 40% and 22%, respectively. Following exposure to the common disinfectant, 70% ethanol, these failure rates increased to 94% and 56% for polyethylene and polyvinyl chloride gloves, respectively. Latex, although permeable to ethanol, was penetrated by virus less than 1% of the time regardless of whether the latex had been pre-exposed to disinfectant or not. This study highlights the need for caution on the part of those who rely upon examination gloves for protection from infectious agents as well as the need for establishing more adequate standards and testing procedures for their manufacture.  相似文献   

7.
Ko JC  Evans LE  Althouse GC 《Theriogenology》1989,31(6):1159-1164
It is known that several materials used in semen collection have been found to be detrimental to spermatozoal motility. In this study, examinations for toxic effects of latex and vinyl gloves, used with and without talcum powder on boar spermatozoa, were performed. Ten boars of known fertility with >/=80% sperm motility were divided into two groups (n = 5 boars each) for in vitro and in vivo studies. In the in vitro study, semen was collected from each of the five boars and was divided into five separate aliquots (5 ml each). One aliquot from each of the boars remained as the control, while the remaining aliquots were divided into individual treatments exposing the semen to a l cm(2) piece of latex or vinyl glove with or without talcum powder. In the in vivo experiment, semen from each of the five boars was collected using a gloved hand. During collection, the first half of the sperm-rich fraction was collected into a filtered sterile container, while the second half of the fraction was allowed to run through the palm of either a latex or vinyl powdered glove prior to collection in the container. In both experiments, semen sample motility was assessed by two independent observers at 1 minute after exposure. Results of both experiments consistently showed a significant (P<0.05) effect of latex gloves (with or without talcum powder) on boar semen when compared with the control semen. Motility was at or near 0% at 1 min after exposure to latex. No significant difference (P>0.05) in motility was observed between the control semen and the semen exposed to talcum powdered vinyl gloves. These results show that latex gloves are detrimental to boar spermatozoa. Therefore, it is suggested that when collecting boar semen vinyl gloves should be used.  相似文献   

8.
Zoos use ambassador animals in educational programs featuring close contact with humans. Chinchillas (Chinchilla lanigera) at the Saint Louis Zoo are retrieved for programs by a keeper wearing brown handling gloves, but green cleaning gloves are worn during normal husbandry when physical contact with the animal is only incidental. The chinchillas’ primary keeper anecdotally reported more reactivity and movement from chinchillas when approached with handling gloves. Animals’ behavioral reactions to the presence of humans often include locomotion and vigilance, but these responses may be attenuated by predictability. To investigate these behaviors, handling trials involving brief contact attempts with both cleaning and handling gloves were filmed. Results indicated that chinchillas responded to disturbances by moving, jumping, and adopting more alert body postures. Surprisingly, movement was recorded in longer durations when the keeper attempted to touch the animals with cleaning gloves. This higher arousal may indicate that the animal was not expecting to be handled, yet an attempt to do so was being made. This reaction provides evidence that potentially aversive events should be reliably and consistently signaled.  相似文献   

9.
This study was initiated to understand why talc was found in the entrance wounds and pericapsular scars of patients with silicone breast implants. Twenty-five surgical gloves made between 1977 and 1992 by a major glove manufacturer were evaluated with infrared spectroscopy. Seven gloves manufactured before early 1983 contained talc. Later manufactured gloves contained calcium carbonate instead of talc. Talc-containing gloves were submitted to independent laboratories for scanning electron microscopic examination and x-ray microanalysis to obtain finer detail. Remnants of the mold-release agent talc were found in the matrix of the patient-contact side of the glove. Wetting studies showed that silicone oil (gel bleed) immediately wet the surface of rubber glove. After donning, silicone oil was massaged between the thumb and index finger of each washed, talc-containing glove for 1 minute and then daubed from the glove to a microscopic slide. The slide was viewed with polarized light microscopy for the presence of talc crystals. Transfer of talc occurred using silicone oil, but not saline, in each talc-containing glove. Three factors were likely involved in the greater talc deposition that occurred with patients undergoing silicone gel-filled breast implantation than in patients undergoing other surgical procedures. (1) The wetting of the gloves with silicone gel bleed from implants loosened the talc in the glove matrix. (2) Hand-intensive surgical use freed the talc from the gloves. (3) Loose talc adhered to the silicone elastomer of the breast implants and was deposited with implant placement.  相似文献   

10.
The effect of pretreatment of several cis-1,4-polyisoprene containing rubbers on their biodegradability was examined. Tests were carried out with six recently isolated and characterized rubber degrading bacteria belonging to the genera Gordonia (strains Kb2, Kd2 and VH2), Mycobacterium, Micromonospora and Pseudomonas. All strains were able to use natural rubber (NR) as well as NR latex gloves as sole carbon source. Extraction of NR latex gloves by organic solvents resulted in an enhancement of growth for three of the selected strains. On the other hand, growth of Gordonia sp. (strain Kb2 and Kd2), Mycobacterium fortuitum NF4 and Micromonospora aurantiaca W2b on synthetic cis-1,4-polyisoprene did only occur after removal of the antioxidants, that are usually added during manufacture to prevent aging of the materials. Detailed degradation studies performed with Gordonia sp. Kb2 revealed an enhanced mineralization of pretreated NR latex gloves and mineralization of purified natural rubber (NR), indicating the actual mineralization of cis-1,4-polyisoprene rubber constituent even after removal of non-rubber constituent that may act as co-metabolic substrate and support microbial growth. Further analysis by scanning electron microscopy (SEM) clearly demonstrated the enhanced colonization efficiency of these bacteria towards pretreated NR latex gloves. Colonization was additionally visualized by staining of overgrown NR latex gloves with Schiff's reagent, and the purple color produced in the area of degradation was an evidence for the accumulation of aldehydes containing oligomers. Further enhancement of latex gloves degradation could be achieved after successive replacement of mineral salts medium during cultivation. Thereby, a rapid disintegration of untreated NR latex gloves material was accomplished by Gordonia sp. strain VH2.  相似文献   

11.
Five female workers were monitored for 5 consecutive days during re-entry into a greenhouse containing ornamental plants. Skin contamination (excluding hands) was evaluated with nine pads of filter paper placed on the skin. Hand contamination was assessed by washing with 95% ethanol. Respiratory exposure was evaluated by personal air sampling. The respiratory dose was based on a lung ventilation of 15 l/min. The doses absorbed were estimated assuming 10% skin absorption and 100% lung retention. Dislodgeable foliar residue was determined on days of re-entry to evaluate the decay of chlorothalonil. Chlorothalonil was analysed in the different matrices by GC-MS. Respiratory exposure was less than skin contamination, being 11.4+/-5.1% (mean+/-SD) of total exposure. The estimated total absorbed dose did not exceed the acceptable daily intake of 0.03 mg/kg body mass. The hands and unexposed skin of all workers were always found to be contaminated. Greater precautions are therefore needed to reduce skin exposure (clean gloves and suitable clean clothing every day).  相似文献   

12.
We have reported previously (H. R. Kotilainen, J. P. Brinker, J. L. Avato, and N. M. Gantz, Arch. Intern. Med. 149:2749-2753, 1989) that the quality of nonsterile examination gloves available for clinical use may be extremely variable. In view of the concern over human immunodeficiency virus and hepatitis B virus transmission to health care workers, the continuing variability of gloves available for use, and the need for a simple and safe test, we have evaluated 2,500 vinyl (five brands) and 2,000 latex (four brands) gloves by the 300-ml and the newly proposed 1,000-ml water tests and for permeability to herpes simplex virus type 1 and poliovirus type 1, respectively. While all 300-ml watertight gloves were unlikely to leak herpes simplex virus type 1 (1.3% vinyl; 0.5% latex), poliovirus was recovered much more frequently (8.9% vinyl, 6.1% latex). In all gloves that passed the 1,000-ml test, herpes simplex virus type 1 was not recovered. Poliovirus was recovered infrequently (1.4% vinyl, 1.5% latex). Preliminary analyses suggest that the 1,000-ml water test has significantly increased sensitivity over the 300-ml water test in the detection of small holes in both vinyl and latex gloves that may allow the passage of viral particles. Gloves that pass a 1,000-ml water challenge are unlikely to allow the passage of a small virus such as poliovirus. Given that human immunodeficiency virus, hepatitis B virus and herpes simplex virus type 1 are larger particles than poliovirus, gloves that pass the 1,000-ml water test theoretically could provide better protection.  相似文献   

13.
We have reported previously (H. R. Kotilainen, J. P. Brinker, J. L. Avato, and N. M. Gantz, Arch. Intern. Med. 149:2749-2753, 1989) that the quality of nonsterile examination gloves available for clinical use may be extremely variable. In view of the concern over human immunodeficiency virus and hepatitis B virus transmission to health care workers, the continuing variability of gloves available for use, and the need for a simple and safe test, we have evaluated 2,500 vinyl (five brands) and 2,000 latex (four brands) gloves by the 300-ml and the newly proposed 1,000-ml water tests and for permeability to herpes simplex virus type 1 and poliovirus type 1, respectively. While all 300-ml watertight gloves were unlikely to leak herpes simplex virus type 1 (1.3% vinyl; 0.5% latex), poliovirus was recovered much more frequently (8.9% vinyl, 6.1% latex). In all gloves that passed the 1,000-ml test, herpes simplex virus type 1 was not recovered. Poliovirus was recovered infrequently (1.4% vinyl, 1.5% latex). Preliminary analyses suggest that the 1,000-ml water test has significantly increased sensitivity over the 300-ml water test in the detection of small holes in both vinyl and latex gloves that may allow the passage of viral particles. Gloves that pass a 1,000-ml water challenge are unlikely to allow the passage of a small virus such as poliovirus. Given that human immunodeficiency virus, hepatitis B virus and herpes simplex virus type 1 are larger particles than poliovirus, gloves that pass the 1,000-ml water test theoretically could provide better protection.  相似文献   

14.
为揭示和探讨中国大鲵(Andrias davidianus)繁殖前期的冲凉行为及其意义,在仿生态养殖环境条件下,采用定时定点观察法和全事件记录法,对中国大鲵冲凉行为的过程及姿势进行了观察记录,进而研究了冲凉行为与年龄、求偶行为之间的关系。结果表明,雄性成鲵表现出冲凉行为,冲凉过程包括冲凉试探、姿势调整、冲凉和离开等4个阶段;冲凉姿势可分为头部冲凉、躯干冲凉、尾部冲凉、移动冲凉、环抱冲凉、贴壁冲凉和抬头冲凉等7种;雄性成鲵的冲凉行为与求偶行为之间存在极显著的正相关。本文认为,雄性成鲵可能通过冲凉行为来促进精巢的发育,进而通过求偶行为达到自然配对并成功繁殖、最终实现种族延续的目的。  相似文献   

15.
In order to evaluate the safety of the individual protection devices, the permeability of four different types of disposable gloves, commonly used in hospitals, was tested in relation to [99mTc]-pertechnetate and to [18F]-fluorodeoxyglucose ([18F]-FDG).From these radiopharmaceutical solutions, a drop was deposited on the external surface of the glove which was opened and stretched with the external surface placed upward. The smear test technique permitted to evaluate the activity onto the inner surface of the glove at different times. The smear tests were measured in a well sodium iodide detector calibrated in efficiency for 99mTc and 18F. The permeability was tested on ten samples of each type of gloves and was expressed as the ratio of the activity onto the inner surface at each time interval to the activity deposited on the external surface of the glove. For each type of gloves and for each sampling time, mean value, standard deviation and percentage coefficient of variation of permeability were evaluated.One type of gloves showed a low resistance to permeation of both radiopharmaceuticals, while another one only to pertechnetate. The other gloves were good performers.The results of this study suggest to test permeability for gloves used for handling radiopharmaceuticals, before their adoption in the clinical routine. This practice will provide a more careful service of radiation protection for nuclear medicine department staff.  相似文献   

16.
Monitoring the atmosphere in an anaerobic chamber   总被引:2,自引:1,他引:1       下载免费PDF全文
The Couloximeter, a fuel cell designed to measure trace amounts of oxygen, was used to monitor the atmosphere in an anaerobic chamber. The device, easy to operate and to maintain, allowed both major and minor fluctuations in oxygen concentration to be measured. Using a hose attached to the outlet within the box, defective (ruptured) gloves were consistently distinguishable from intact gloves.  相似文献   

17.
Two studies of the behaviour of cytosolic phospholipase A(2) (cPLA(2)) in the red blood cell (RBC), as measured by ELISA, are described. In the first study we show a significant increase in cPLA(2) in patients with schizophrenia compared to controls and suggest that this measure, if corroborated, could be used as a diagnostic marker. In a second study we found that washing the RBC introduced an unknown confounding variable which led us to reject this study. A subsequent investigation of washing red cells showed that the washing effect may be due to a plasma factor likely to be more than 5kDa MW which can be removed from red cells by washing with buffers. When the cells are washed, the concentration of cPLA(2) in the red cell, as measured by ELISA, significantly increases. We advise against washing the red cell in any study that involves measuring cPLA(2) by ELISA.  相似文献   

18.
Failure in the prevention of cross-transmission from contaminated gloves has been recognized as an important factor that contributes to the spread of several healthcare-associated infections. Ex situ coating process with silver nanoparticles (AgNPs) using Eucalyptus citriodora ethanolic leaf extract as reducing and capping agents to coat glove surfaces has been developed to prevent this mode of transmission. Elemental analysis of coated gloves showed 24.8 Wt% silver densely adhere on the surface. The coated gloves fully eradicated important hospital-acquired pathogens including Gram-positive bacteria, Gram-negative bacteria, and yeasts within 1 h. The coated gloves showed significant reduction, an average of five logs when tested against all standard strains and most clinical isolates (< 0.01). Following prolonged exposure, the coating significantly reduced the numbers of most adhered pathogenic species, compared with uncoated gloves (p < 0.0001). AgNPs-coated gloves reduced microbial adhesion of mixed-species biofilms. A series of contamination and transmission assays demonstrated no transmission of viable organisms. Biocompatibility analysis confirmed high viability of HaCaT and L929 cells at all concentrations of AgNPs tested. The coated gloves were non-toxic with direct contact with L929 cells. The highly efficacious AgNPs-coated gloves potentially provide additional protection against transmission of healthcare-associated infections.  相似文献   

19.
20.
This article addresses the role of glove powder in facilitating allergic reactions to natural rubber latex (NRL) and to the chemical additives in synthetic and NRL gloves as well as its role in eliciting postsurgical complications. Various dusting powders have been used historically to prevent gloves from sticking to each other and to facilitate donning. All have manifested adverse consequences for health care professionals and patients. Manufacturing methods for powder reduction and elimination are presented. The recently developed ASTM methods for the quantitation of powder on powder-free and powdered gloves are reviewed along with the new ASTM maximum powder limits for all medical gloves. Caution must be exercised when methods of protein and powder reduction are implemented to minimize the possibility of creating other adverse consequences.  相似文献   