1.
A method, using 0.2 ml of plasma, was designed for the simultaneous determination of morphine, 6-monoacetylmorphine, amphetamine, methamphetamine, MDA, MDMA, MDEA, MBDB, benzoylecgonine and cocaine. The drugs were analysed by LC-MS, after solid phase extraction in the presence of the deuterated analogues. Reversed phase separation on an Atlantis dC18 column was achieved in 10 min, under gradient conditions. The method was full validated, including linearity (2-250 ng/ml, r2>0.99), recovery (>50%), within-day and between-day precision and accuracy (CV and bias <15%), limit of detection (0.5 and 1 ng/ml) and quantitation (2 ng/ml), relative ion intensities and no matrix effect was observed. The procedure showed to be sensitive and specific, and was applied to 156 real cases from road fatalities (7.1% cases positive to cocaine and 0.6% to designer drugs).  相似文献   

2.
A high-performance liquid chromatographic method for the enantiospecific quantitation of S- and R-mephenytoin and its metabolites S- and R-nirvanol and S- and R-4'-hydroxymephenytoin in plasma is described. The compounds were separated using a reversed-phase C(2) column in tandem with a chiral alpha(1)-acid glycoprotein column and were detected using ultraviolet detection at 205 nm. The lower limit of quantification was 10 ng/ml for all compounds using 0.5 ml human plasma (intra-day coefficient of variation <13%, accuracy <+/-20%). The method was validated for human plasma in the concentration range 10-2000 ng/ml for each of the six compounds. The method allows for the simultaneous characterisation of the metabolic capacity of two human drug-metabolising enzymes, CYP2C19 and CYP2B6, and may be used when investigating polymorphisms or changes in activity of these two enzymes.  相似文献   

3.
There is considerable interest in quantifying morphine and its major metabolites, morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G). Available assays use gas chromatography-mass spectrometry or high-performance liquid chromatography (HPLC) with single or tandem mass spectrometry, ultraviolet, electrochemical, or fluorimetric detection. Nevertheless, few methods provide adequate sensitivity for all analytes, in a single injection, with the desired rate of sample throughput. A rapid and sensitive method for quantification of morphine, M3G and M6G from human plasma using HPLC with electrospray ionization mass spectrometry was developed using a Waters Oasis MCX 96-well plate for extracting both lipophilic morphine and its hydrophilic glucuronides, C18 separation using an isocratic mobile phase (methanol, acetonitrile and formic acid), and selected ion monitoring. Recoveries of morphine, M3G and M6G, respectively, were 81, 90 and 82% at the low (2, 25 and 2 ng/ml), 80, 77 and 75% at the medium (10, 250 and 10 ng/ml), and 74, 62 and 72% at the high (100, 1000 and 100 ng/ml) quality control samples. The limit of quantitation was 0.5 ng/ml morphine and M6G, and 5 ng/ml M3G. Analytes were validated over a linear range of 0.5-200 ng/ml morphine and M6G, and 5-2000 ng/ml M3G. This assay represents an improvement over existing methods through solid phase extraction with increased sample throughput (96-well plates), use of small samples (0.5 ml), and sub-nanogram detection.  相似文献   

4.
A rapid, accurate and selective method for the determination of isosorbide dinitrate and its 2- and 5-isosorbide mononitrate metabolites in 1.0 ml of human plasma has been developed. Before chromatographic quantitation by gas-liquid chromatography with electron-capture detection, the compounds are subjected to solid-phase extraction, using ENVI 18 cartridges (Supelco). The intra-day and inter-day coefficients of variation are less than 10%, except the inter-day coefficient of variation for the assay of 5-isosorbide dinitrate which is less than 15%. Limits of quantitation are 10, 10 and 20 ng/ml for isosorbide dinitrate, 2-isosorbide mononitrate and 5-isosorbide mononitrate, respectively. Recoveries are in excess of 90% for isosorbide dinitrate and 70% for its two metabolites.  相似文献   

5.
A selective and sensitive high-performance liquid chromatographic method was developed for the separation and quantitation of daunorubicin and its metabolites in serum, plasma, and other biological fluids. Daunorubicin and metabolites in human plasma were injected directly into the high-performance liquid chromatography system via a loop-column to pre-extract the drugs from the plasma, and quantitated against a multilevel calibration curve with adriamycin as the internal standard. The column effluent was monitored with an electrochemical detector at an applied oxidative potential of 0.65 V and by fluorescence. Daunorubicin and four metabolites were separted and characterized by this method. In a blinded evaluation of accuracy and precision, the mean coefficients of variation were 3.8, 3.6 and 9.8% at concentrations of 150, 75 and 15 ng/ml, respectively, and blank samples gave negligible readings. The amperometric sensitivity was greater than achieved by fluorescence detection, and offers an alternative method for quantitation of these compounds. The new method has a limit of detection of less than 2 ng on column, allowing quantitation of < 10 ng/ml in plasma samples without organic extraction prior to chromatographic analysis.  相似文献   

6.
A reversed-phase, ion-pair liquid chromatographic method for the quantitative determination of quaternary acetylcholinesterase inhibitors is described. The method uses an ion-pair extraction to isolate the drugs from biological material prior to liquid chromatographic separation and online UV detection at 214 nm. Quantitation down to 5 ng/ml and within-day precision with coefficient of variation (C.V.) of 1.5% (n=10, x = 100 ng/ml) for neostigmine, C.V., 1.7% (n=10, x = 80 ng/ml) for pyridostigmine and C.V., 1.5% (n=10, x = 100 ng/ml) for edrophonium have been achieved. The assay was designed for pharmacokinetic studies of these drugs in anesthetized patients.  相似文献   

7.
A simple and rapid high-performance liquid chromatographic method with fluorescence detection was developed for the determination of loratadine in small volume plasma samples. Liquid-liquid extraction of loratadine and diazepam (as internal standard) from plasma samples was performed with n-butyl alcohol/n-hexane (2:98, v/v) in alkaline condition followed by back-extraction into diluted perchloric acid. Chromatography was carried out using a C8 column (250 x 4.6 mm, 5 microm) under isocratic elution with acetonitrile-20 mM sodium dihydrogen phosphate-triethylamine (43:57:0.02, v/v), pH 2.4. Analyses were run at a flow-rate of 1.0 ml/min at room temperature. The method was specific and sensitive with a quantitation limit of 0.62 ng/ml and a detection limit of 0.2 ng/ml at a signal-to-noise ratio of 3:1. The mean absolute recovery of loratadine from plasma was 84%, while the intra-and inter-day coefficient of variation and percent error values of the assay method were all less than 9.7%. Linearity was assessed in the range of 0.62-20 ng/ml in plasma with a correlation coefficient of greater than 0.999. The method has been used to analyze several hundred human plasma samples for bioavailability studies.  相似文献   

8.
Piperine, a major alkaloid of Piper longum and Piper nigrum has been reported to have several pharmacological/toxicological effects. Though a number of methods for analysis of this omnipresent food component in pepper fruits are available, its analysis in body fluids has been largely neglected. A high-performance liquid chromatography method for the analysis of piperine in rat plasma is presented in this communication. Analysis was performed using a Symmetry C(18) column (250x4.6 mm) by isocratic elution with 25 mM KH(2)PO(4) (pH 4.5)-acetonitrile (35:65) and UV detection at 340 nm. The calibration plot was linear over the range studied (2-2000 ng) with correlation coefficient of 0.9984. Limit of detection and limit of quantitation were 1 ng/ml and 3 ng/ml, respectively. Good overall recovery (85.5+/-6%) was obtained with 4 ml ethyl acetate and extraction time of 3 min. Intra- and inter-assay coefficient of variation was found to be less than 7.5%. Plasma concentration-time profile of piperine in a conscious rat implanted with jugular vein cannula was obtained using this method. The method is simple, sensitive and reproducible.  相似文献   

9.
A gas chromatographic–mass spectrometric method was developed for the determination of residues of clenbuterol in bovine urine. The method involves a simple cation-exchange clean-up and concentration of clenbuterol in the acidified urine, followed by ethyl acetate extraction. The analyte is determined as the di-trimethylsilyl derivative and quantitated against an internal standard of penbutolol. Using a 5-ml sample of urine, a detection limit of 0.07 ng/ml can be achieved with recoveries close to 100% for fortification levels of 0.2 and 1 ng/ml. By increasing the sample volume to 50 ml, a detection limit below 0.01 ng/ml was achievable with recovery averaging 70%. The coefficient of variation of the assay ranged from 15% at 0.01 ng/ml (50-ml sample) to 6% at 1 ng/ml (5-ml sample). It was demonstrated that the method can detect the presence of clenbuterol in bovine urine at sub-ppb (ng/ml) levels using low resolution GC–MS with electron impact (EI) ionization.  相似文献   

10.
A simple, rapid, specific and sensitive high-performance liquid chromatography method has been developed for quantitation of 5-fluorouracil (5-FU) in human plasma. The method involves deproteinization of a small sample volume of plasma (150 μl) followed by HPLC on a cation-exchange resin column, Aminex HPX-87H (300×7.8 mm I.D.), preceded by a similar guard cartridge with UV detection at 265 nm. This method allows a good separation of 5-FU with a retention time of 24 min and a detection limit at 25 ng/ml. The calibration curve was linear from 25 to 2000 ng/ml. The coefficient of variation was ≤4.4% for within-day reproducibility and ≤9.5% for day-to-day reproducibility.  相似文献   

11.
We developed a sensitive and selective method for determining levels of sultopride, a neuroleptic drug of the substituted benzamide, in human plasma using high-performance liquid chromatography (HPLC) combined with UV detection and particle beam mass spectrometry (PBMS). Sutopride was extracted with tert.-butylmethyl ether using a salting-out technique. Tiapride served as an internal standard (I.S.). Sutopride and I.S. were separated by HPLC on a silica column with a mobile phase of acetonitrile-0.1 M ammonium acetate (94:6, v/v). The calibration curves were linear over the concentration range from 5 to 1000 ng/ml by HPLC with UV detection and from 10 to 1000 ng/ml with PBMS detection. The limit of quantitation was 5 ng/ml with UV detection and 10 ng/ml with PBMS detection. The absolute recovery was 92% and the within-day coefficients of variation were 2.9–7.1% at plasma concentrations from 50 to 500 ng/ml, determined by HPLC with UV detection. Using this method, we measured the plasma concentrations of sultopride with replicate analyses in four hospitalized patients and steady-state plasma levels were determined to be 161.6±30.8, 321.1±93.7, 726.5±143.1 and 1273.6±211.2 ng/ml, respectively.  相似文献   

12.
A method for the determination of amitriptyline-N-oxide, amitriptyline and nortriptyline in serum and plasma has been developed. After extraction from serum or plasma the drugs were analysed by high-performance liquid chromatography.The detection limit was 10 ng/ml (2 ml serum or plasma actually used). The coefficient of variation for all three compounds was below 10%.Amitriptyline-N-oxide was found in rat plasma after an oral dose (10 mg/kg) of amitriptyline-N-oxide.  相似文献   

13.
An isocratic online-enrichment HPLC-assay was developed allowing for the simple and fast separation and quantitation of STI-571 and its main metabolite N-desmethyl-STI (N-DesM-STI) in plasma, urine, cerebrospinal fluid (CSF), culture media and cell preparations in various concentrations using UV-detection at 260 nm. The analytical procedure consists of an online concentration of STI-571 and N-DesM-STI in the HPLC system followed by the elution on a ZirChrom-PBD analytical column. Time of analysis is 40 min including the enrichment time of 5 min. The detection limit is 10 ng/ml in plasma, CSF, culture medium (RPMI) and 25 ng/ml in urine for both STI-571 and N-DesM-STI. The intra-day precision, as expressed by the coefficient of variation (CV), in plasma samples ranges between 1.74 and 8.60% for STI-571 and 1.45 and 8.87% for N-DesM-STI. The corresponding values for urine measurements are 2.17-7.54% (STI-571) and 1.31-9.51% (N-DesM-STI). The inter-day precision analyzed over a 7-month time period was 8.31% (STI-571) or 6.88% (N-DesM-STI) and 16.45% (STI-571) or 14.83% (N-DesM-STI) for a concentration of 1000 ng/ml in plasma and 750 ng/ml in urine, respectively. Moreover, we demonstrate that with an alternative, but more time and labor consuming sample preparation and the implementation of electrochemical detection, a detection limit < 10 ng/ml can be achieved. The method described was used to perform pharmacokinetic measurements of STI-571 and N-desmethyl-STI in patient samples and for kinetic measurements of intracellular STI-571 and N-DesM-STI following in vitro incubation.  相似文献   

14.
We have developed a sensitive, selective and reproducible reversed-phase HPLC method with ultraviolet detection (340 nm) for the simultaneous quantification of amodiaquine (AQ) and its major metabolite, desethylamodiaquine (AQm) in a small volume (200 microl) of whole blood spotted on filter paper. The method involves liquid-liquid extraction with diethyl ether followed by elution from a reversed-phase phenyl column with an acidic (pH 2.8) mobile phase (25 mM KH2PO4-methanol; 80:20% (v/v) +1% (v/v) triethylamine). Calibration curves in spiked whole blood were linear from 100-2500 ng/ml (r2 > or = 0.99) for AQ and 200-2500 ng/ml (r2 > or = 0.99) for AQm. The limit of detection was 5 ng for AQ and 10 ng for AQm. The relative recovery at 150 ng/ml of AQ (n = 6) was 84.0% and at 300 ng/ml of AQm the relative recovery was 74.3%. The intra-assay coefficients of variation at 150, 600 and 2250 ng/ml of AQ and 300, 600 and 2250 ng/ml of AQm were 7.7, 8.9 and 6.2% (AQ) and 10.1, 5.4 and 3.9% (AQm), respectively. The inter-assay coefficient of variation at 150, 600 and 2250 ng/ml of AQ and 300, 600 and 2250 ng/ml of AQm were 5.2, 8.1 and 6.9% (AQ) and 3.3, 2.3 and 4.6% (AQm). There was no interference from other commonly used antimalarial and antipyretic drugs (chloroquine, quinine, sulfadoxine, pyrimethamine, artesunate, acetaminophen and salicylate). The method is particularly suitable for pharmacokinetic studies in settings where facilities for storing blood/plasma samples are not available.  相似文献   

15.
Morphine is present in varying amounts as an endogenous product in human urine. Derivatization of morphine contained in urine with dansyl chloride yields a known product, which can be quantified by liquid chromatography mass spectrometry with high selectivity and sensitivity. Urine samples of 51 healthy individuals were spiked with stable-isotope labeled morphine, hydrolyzed and subjected to solid phase extraction followed by derivatization of morphine with dansyl chloride. The dansyl derivatives of naturally occurring morphine and deuterated internal standard were then detected by liquid chromatography-triple quadrupole mass spectrometry. Using the [N-CD(3)]-labeled internal standard and solid-phase extraction, a limit of detection of 35 fmol/ml (10 pg/ml) and a limit of quantification of 87.5 fmol/ml (25 pg/ml) was determined for morphine in human urine. This new LC-MS/MS method allowed the detection of endogenous morphine in human urine of 51 volunteers with an average value of 156.4 fmol/ml (44.7 ng/ml).  相似文献   

16.
Physostigmine (PHY) is an anticholinergic drug used in the treatment of neuromuscular disorders and organophosphate poisoning. We described a sensitive, accurate, and reproducible method for PHY determination in biological materials. The method utilized a liquid/liquid, ion pair extraction, normal phase HPLC separation, and fluorometric quantitation at 240 nm excitation and 360 nm emission wavelength. We used neostigmine as a stabilizing agent to protect PHY from degradation and dimethylphysostigmine as an internal standard. The peak-height ratio vs concentration was linear over a working range from 0.50 to 25.0 ng/ml of PHY in plasma. Sensitivity of the method was 100 pg/ml of plasma which was the limit of quantitative detection under the experimental conditions used. Precision of the method was evaluated using plasma spiked with two concentrations of PHY: 1.0 and 10.0 ng/ml. Intra-day coefficient of variation (CV) ranged from 3.8 to 5.3%, and inter-day CV ranged from 1.8 to 3.6% for the two levels. The average recovery was 92%. We applied the method to examine the stability of PHY in plasma stored at -15 and -80 degrees C. The data indicated that PHY can be stored at either temperature for 9 weeks without undergoing significant alterations.  相似文献   

17.
Two methods for the extraction of morphine from cerebrospinal fluid or plasma with quantitation by high-performance liquid chromatography with electrochemical detection were compared for accuracy, precision and ease of preparation. One procedure was a standard extraction procedure and the other utilized a commercially available liquid—liquid extraction column. Both methods produced linear calibration curves over the concentration range of 1–200 ng/ml with coefficients of correlation of 0.999. Since the electrochemical detector is capable of detecting 20 pg of morphine, biological samples as small as 0.1 to 0.4 ml can be quantified with an average relative precision of 4.1 ± 3.9% over the concentration range 1–200 ng/ml. The potential clinical importance of the assay is demonstrated using a time course distribution study of morphine in the cerebrospinal fluid and plasma of a Rhesus monkey.  相似文献   

18.
A selective and sensitive LC/MS/MS assay was developed for the quantification of d(2)-nicotine and d(2)-cotinine in plasma of current and past smokers administered d(2)-nicotine. After solid phase extraction and liquid-liquid extraction, HPLC separation was achieved on a capillary hydrophilic interaction chromatography phase column. The analytes were monitored by tandem mass spectrometry with electrospray positive ionization. Linear calibration curves were generated for d(2)-nicotine (0.03-6.0 ng/ml plasma) and d(2)-cotinine (0.15-25 ng/ml plasma). The lower limits of quantitation were 0.15 ng/ml and 0.25 ng/ml for d(2)-nicotine and d(2)-cotinine, respectively. The coefficient of variation was 3.7% for d(2)-nicotine and 2.5% for d(2)-cotinine. The method was applied to two ongoing studies of d(2)-nicotine metabolism in prior and current smokers. Preliminary analysis of a subset of subjects from these studies detected a significantly lower rate of nicotine conversion to cotinine by past smokers compared to current smokers.  相似文献   

19.
A high-performance liquid chromatographic method is described for the determination of free captopril in human plasma. (NAC) was used as an internal standard. Plasma samples were immediately derivatized with N-(1-pyrenyl)maleimide (NPM) and stabilized with 11 M HCl. The drug of interest was isolated using a liquid-liquid extraction with ethyl acetate and separation was obtained using a reversed-phase column under isocratic conditions with fluorescence detection. The sample volume was 150 μl plasma. The intra- and inter-day accuracy and precision, determined as relative error and coefficient of variation respectively, were lessthan 10%. The lower limit of quantitation, based on standards with acceptable coefficients of variation, was 25 ng/ml. No endogenous compounds were found to interfere. The linearity was assessed in the range of 25–600 ng/ml. This method has been demonstrated to be suitable for pharmacokinetic studies in humans.  相似文献   

20.
A sensitive and specific high-performance liquid chromatographic (HPLC) method for the determination of cortisol in only 200 microliters of serum is described. Cortisol and two internal standards, 19-nortestosterone (IS1) and 6 alpha-methylprednisolone (IS2) are extracted with dichloromethane and analyzed on a C18 reversed-phase column eluted with a mobile phase of methanol:water at a flow rate of 0.75 ml/min. Ultraviolet absorption at 254 nm is used for detection and quantitation is performed by peak height ratio measurement. Using 200 microliters of serum, the lower limit of detection for cortisol is 10 ng/ml, the analytical recovery is 104 +/- 3.6% (n = 8), and the day-to-day precision was 1.69% at a level of 90 ng/ml (n = 16). Cortisol values obtained by this method were generally lower than those obtained by radioimmunoassay or by fluorometry. A serum pool was analyzed both by HPLC and by isotope dilution/mass spectrometry (ID/MS). A mean value of 90.1 ng/ml was obtained by HPLC (n = 16, CV = 1.7%), whereas ID/MS yielded a mean of 90.8 ng/ml (n = 28, CV = 0.4%). These results clearly demonstrate the high specificity and the accuracy of the HPLC procedure. The use of two internal standards not only compensates for losses during the sample manipulation but also prevents erroneous results in case of medication by either of these two products.  相似文献   